		 P3AM-4822-12ENZ0   
					ETERNUS DX80 S2/DX90 S2   
					Disk storage system   
					User's Guide -Site Planning-   
				Preface   
					Fujitsu would like to thank you for purchasing our ETERNUS DX80 S2/DX90 S2 Disk storage system.   
					The ETERNUS DX80 S2/DX90 S2 Disk storage system is designed to be connected to Fujitsu (PRIMEQUEST or   
					PRIMERGY) or non-Fujitsu servers.   
					This manual describes the environmental requirements that are necessary to install and use the ETERNUS   
					DX80 S2/DX90 S2 Disk storage system.   
					This manual is intended for use of ETERNUS DX80 S2/DX90 S2 Disk storage system in regions other than Japan.   
					Please carefully review the information outlined in this manual.   
					Twelfth Edition   
					June 2013   
					Microsoft, Windows, Windows Server, and Internet Explorer are either registered trademarks or trademarks of   
					Microsoft Corporation in the United States and/or other countries.   
					Mozilla, Firefox, and the Mozilla and Firefox logos are trademarks or registered trademarks of the Mozilla   
					Foundation in the United States and other countries.   
					The company names, product names and service names mentioned in this document are registered   
					trademarks or trademarks of their respective companies.   
					3 
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
				About this Manual   
					Organization   
					This manual is composed of the following four chapters:   
					
					This chapter describes the main components and the relative optional products that are installed in the   
					ETERNUS DX80 S2/DX90 S2 Disk storage system.   
					
					This chapter describes the installation specifications, the installation environment, and the power   
					requirements.   
					
					This chapter describes the configuration for each interface to connect to the ETERNUS DX80 S2/DX90 S2   
					Disk storage system.   
					
					This chapter describes the requirements for rack installation.   
					This chapter also describes the standard installation rules (installation locations and installation order) of   
					the optional products before shipment from the factory when the optional products are purchased with the   
					ETERNUS DX80 S2/DX90 S2 Disk storage system at the same time.   
					Naming Conventions   
					■ Abbreviations used in this manual   
					• "ETERNUS DX Disk storage system" refers to the ETERNUS DX80 S2/DX90 S2 Disk storage system.   
					• "CA" refers to a host interface module that is used in an ETERNUS DX Disk storage system to connect to a   
					server.   
					• "Host Bus Adapter (HBA)" refers to the interface module that is normally used by the server to connect to   
					ETERNUS DX Disk storage systems.   
					An "FC card", "LAN card", "Network Interface Card (NIC)", "Converged Network Adapter (CNA)", or "SAS card"   
					may be used instead, depending on the server and interface.   
					• Trademark symbols such as ™ and ® are omitted in this document.   
					4 
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
				About this Manual   
					Warning Notations   
					Warning signs are shown throughout this manual in order to prevent injury to the user and/or material   
					damage. These signs are composed of a symbol and a message describing the recommended level of caution.   
					The following explains the symbol, its level of caution, and its meaning as used in this manual.   
					This symbol indicates the possibility of minor or moderate personal injury, as well   
					as damage to the ETERNUS DX Disk storage system and/or to other users and their   
					property, if the ETERNUS DX Disk storage system is not used properly.   
					CAUTION   
					How Warnings are Presented in this Manual   
					A message is written beside the symbol indicating the caution level. This message is marked with a vertical   
					ribbon in the left margin, to distinguish this warning from ordinary descriptions.   
					An example is shown here.   
					Warning Level Indicator   
					Example Warning   
					Warning Type Indicator   
					Warning Details   
					To avoid damaging the ETERNUS DX Disk storage system,   
					pay attention to the following points when cleaning the ETERNUS DX   
					Disk storage system:   
					- 
					Make sure to disconnect the power when cleaning.   
					- 
					Be careful that no liquid seeps into the ETERNUS DX Disk storage   
					system when using cleaners, etc.   
					- 
					Do not use alcohol or other solvents to clean the ETERNUS DX Disk   
					storage system.   
					Warning Layout Ribbon   
					5 
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
				Table of Contents   
					
					
					
					
					Controller Enclosure .......................................................................................................... 11   
					Controllers ..................................................................................................................................................... 15   
					Power Supply Units ........................................................................................................................................17   
					
					
					
					
					I/O Modules ................................................................................................................................................... 21   
					Power Supply Units ........................................................................................................................................22   
					
					
					
					Enclosure Connection Path ............................................................................................... 22   
					
					
					2.5" Drives ..................................................................................................................................................... 23   
					3.5" Drives ..................................................................................................................................................... 24   
					
					
					
					Power Distribution Units (Only for Regions Other than EMEA&I) ...................................... 24   
					
					
					
					
					Installation Specifications ................................................................................................. 27   
					ETERNUS DX80 S2 ..........................................................................................................................................27   
					ETERNUS DX90 S2 ..........................................................................................................................................29   
					
					
					
					
					Controller Enclosure Dimensions ................................................................................................................... 31   
					Drive Enclosure Dimensions .......................................................................................................................... 33   
					
					
					
					
					Package Size ..................................................................................................................... 35   
					Installation Area ............................................................................................................... 36   
					
					Installation Environment .................................................................................................. 36   
					Air Conditioning .............................................................................................................................................36   
					Earthquake Resistance ..................................................................................................................................37   
					
					
					
					
					
					
					Specifications for Optional Power Supply Products .........................................................................................38   
					Required Number of Outlets/Sockets ............................................................................................................. 40   
					
					
					
					Circuit Protectors ............................................................................................................... 41   
					6 
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
				Table of Contents   
					
					
					
					
					Host Connections .............................................................................................................. 46   
					Host Interfaces ..............................................................................................................................................46   
					Host Connection Path ....................................................................................................................................48   
					
					
					
					Remote Connections ......................................................................................................... 52   
					Remote Interfaces .........................................................................................................................................53   
					Connectable Models ......................................................................................................................................54   
					
					
					
					
					LAN Connection ................................................................................................................ 55   
					
					
					UPS Connection .............................................................................................................................................59   
					
					
					
					
					
					
					
					
					Rack Installation Requirements ........................................................................................ 64   
					Placement in the Rack ...................................................................................................................................64   
					Cable Connection ...........................................................................................................................................65   
					
					
					
					Installable Racks ............................................................................................................... 67   
					Fujitsu Racks .................................................................................................................................................. 67   
					Non-Fujitsu Racks ..........................................................................................................................................68   
					
					
					
					
					Host Interfaces ..............................................................................................................................................70   
					Drive Enclosures ............................................................................................................................................71   
					Drives ............................................................................................................................................................ 72   
					Drive Installation Examples ........................................................................................................................... 77   
					
					
					
					
					7 
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
				List of Figures   
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					Figure 3.7   
					Front view of a 2.5" type controller enclosure.............................................................................................. 11   
					Rear view of a 2.5" type controller enclosure (single-controller type).......................................................... 12   
					Rear view of a 2.5" type controller enclosure (dual-controller type) ............................................................ 12   
					Top view of a 2.5" type controller enclosure ................................................................................................ 13   
					Side view of a 2.5" type controller enclosure ............................................................................................... 13   
					Front view of a 3.5" type controller enclosure.............................................................................................. 13   
					Rear view of a 3.5" type controller enclosure (single-controller type).......................................................... 14   
					Rear view of a 3.5" type controller enclosure (dual-controller type) ............................................................ 14   
					Top view of a 3.5" type controller enclosure ................................................................................................ 15   
					Side view of a 3.5" type controller enclosure ............................................................................................... 15   
					Front view of a 2.5" type drive enclosure..................................................................................................... 18   
					Rear view of a drive enclosure (single-IOM type) ........................................................................................ 18   
					Rear view of a drive enclosure (dual-IOM type)........................................................................................... 19   
					Top view of a 2.5" type drive enclosure........................................................................................................ 19   
					Side view of a 2.5" type drive enclosure....................................................................................................... 19   
					Front view of a 3.5" type drive enclosure..................................................................................................... 20   
					Rear view of a drive enclosure (single-IOM type) ........................................................................................ 20   
					Rear view of a drive enclosure (dual-IOM type)........................................................................................... 20   
					Top view of a 3.5" type drive enclosure........................................................................................................ 21   
					Side view of a 3.5" type drive enclosure....................................................................................................... 21   
					Enclosure connection path (dual-controller type) ....................................................................................... 22   
					Enclosure connection path (single-controller type)..................................................................................... 23   
					Power distribution unit (AC200-240V, 1U, Max 2 enclosures connection) ................................................... 24   
					Power distribution unit (AC200-240V, 2U, Max 6 enclosures connection) ................................................... 25   
					Power distribution unit (AC200-240V, 2U, Max 8 enclosures connection) ................................................... 26   
					2.5" type controller enclosure dimensions................................................................................................... 31   
					3.5" type controller enclosure dimensions................................................................................................... 32   
					2.5" type drive enclosure dimensions .......................................................................................................... 33   
					3.5" type drive enclosure dimensions .......................................................................................................... 34   
					Installation area and service area ............................................................................................................... 36   
					Power distribution unit (1U)........................................................................................................................ 40   
					Power distribution unit (2U)........................................................................................................................ 41   
					Breaking characteristics of distribution board circuit protectors .................................................................. 42   
					Example of a power supply connection using a power distribution unit (1U).............................................. 43   
					Example of a power supply connection using a power distribution unit (2U).............................................. 44   
					Example of a power supply connection without power distribution units.................................................... 45   
					Single path connection (direct connection)................................................................................................. 48   
					Single path connection (switch connection)................................................................................................ 49   
					Multipath connection (direct connection) ................................................................................................... 49   
					Multipath connection (switch connection) .................................................................................................. 50   
					Connection that satisfies the system requirements (for availability)........................................................... 51   
					Connection that satisfies the system requirements (for enhanced performance)........................................ 51   
					Example of non-supported connection configuration (when multiple types of   
					remote interfaces are installed in the same ETERNUS DX Disk storage system) .......................................... 52   
					Example of supported connection configuration (when multiple types of   
					Figure 3.8   
					remote interfaces are installed in the same ETERNUS DX Disk storage system) .......................................... 52   
					FC connection for remote copy (redundant path)........................................................................................ 53   
					FC connection for remote copy (using lines)................................................................................................ 53   
					
					
					8 
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
				List of Figures   
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					
					iSCSI connection for remote copy (using lines)............................................................................................ 53   
					Example of a LAN connection...................................................................................................................... 55   
					Dual-line power supply when connecting to power sockets......................................................................... 57   
					Dual-line power supply when connecting to UPS units................................................................................ 57   
					Single-line power supply when connecting to power sockets ...................................................................... 57   
					Single-line power supply when connecting to a UPS unit ............................................................................ 58   
					Single-line power supply when connecting to a power socket and a UPS unit............................................. 58   
					Power control using a power synchronized unit (when connecting one or two servers) .............................. 61   
					Power control using a power synchronized unit (when connecting three or more servers) ......................... 62   
					AC cable connection .................................................................................................................................... 65   
					QSFP cable connection (single-controller type)........................................................................................... 66   
					QSFP cable connection (dual-controller type).............................................................................................. 67   
					Unit installation area .................................................................................................................................. 68   
					Installation diagram for a host interface (single-controller type)................................................................ 70   
					Installation diagram for host interfaces (dual-controller type).................................................................... 71   
					Installation diagram for 2.5" drives ............................................................................................................. 74   
					Installation diagram for 3.5" drives ............................................................................................................. 76   
					Drive installation example at shipment (2.5" type controller enclosure)..................................................... 77   
					Drive installation example at shipment (3.5" type controller enclosure)..................................................... 78   
					9 
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
				List of Tables   
					
					
					
					
					
					
					
					Table 1.8   
					Host interface specifications........................................................................................................................ 16   
					Drive interface port specifications for controllers......................................................................................... 16   
					LAN port specifications for controllers ......................................................................................................... 17   
					PWC port specifications ............................................................................................................................... 17   
					Drive interface port specifications for I/O modules ...................................................................................... 21   
					2.5" drive specifications............................................................................................................................... 23   
					3.5" drive specifications............................................................................................................................... 24   
					Power distribution unit (AC200-240V, 1U, Max 2 enclosures connection) and   
					provided AC cable specifications.................................................................................................................. 25   
					Power distribution unit (AC200-240V, 2U, Max 6 enclosures connection) and   
					Table 1.9   
					provided AC cable specifications.................................................................................................................. 25   
					Power distribution unit (AC200-240V, 2U, Max 8 enclosures connection) and   
					Table 1.10   
					provided AC cable specifications.................................................................................................................. 26   
					ETERNUS DX80 S2 installation specifications............................................................................................... 27   
					ETERNUS DX90 S2 installation specifications............................................................................................... 29   
					Package size (for regions other than EMEA&I) ............................................................................................ 35   
					Specifications for power cords supplied with the ETERNUS DX Disk storage system   
					
					
					
					Table 2.4   
					(for the EMEA&I region) .............................................................................................................................. 38   
					Specifications for power cords supplied with the ETERNUS DX Disk storage system   
					Table 2.5   
					(for regions other than EMEA&I) ................................................................................................................. 38   
					Specifications for optional power cords (for regions other than EMEA&I).................................................... 38   
					Specifications for power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 1U,   
					
					Table 2.7   
					Max 2 enclosures connection)..................................................................................................................... 39   
					Specifications for power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U,   
					Max 6 enclosures connection)..................................................................................................................... 39   
					Specifications for power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U,   
					Table 2.8   
					Table 2.9   
					Max 8 enclosures connection)..................................................................................................................... 39   
					Required number of outlets and sockets to install power distribution units ................................................ 40   
					Required conditions for distribution board circuit protectors....................................................................... 41   
					Ethernet frame capacity (Jumbo Frame settings)........................................................................................ 47   
					Connectable models and available remote interfaces ................................................................................. 54   
					ETERNUS Web GUI operating environment.................................................................................................. 55   
					Enclosure installation order......................................................................................................................... 64   
					Specifications for the unit installation area................................................................................................. 69   
					Priority order of host interface installation.................................................................................................. 70   
					Priority order of drive enclosure installation (for 2.5" type controller enclosure)......................................... 71   
					Priority order of drive enclosure installation (for 3.5" type controller enclosure)......................................... 71   
					Priority order of 2.5" drive installation......................................................................................................... 72   
					Priority order of 3.5" drive installation......................................................................................................... 75   
					
					
					
					
					
					
					
					
					
					
					
					
					10   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
				Chapter 1   
					Hardware Configurations   
					This chapter explains hardware configurations for the ETERNUS DX Disk storage system.   
					1.1   
					Controller Enclosure   
					This section explains the main components in the controller enclosure.   
					The controller enclosure contains drives installed in the front, and controllers and power supply units in the   
					rear.   
					Since the power supply units are redundant, operations can continue even if one of them fails. There are two   
					models: a single-controller type and a dual-controller type. For a dual-controller type, operations can continue   
					even if one of the controllers fails.   
					• The single-controller type differs from the dual-controller type by the following features:   
					- The controller and I/O module are not duplicated.   
					- Hot maintenance or swapping of the controller and I/O module is not possible.   
					- Concurrent firmware loading or update of the controller firmware and I/O module firmware is not   
					possible.   
					- Multipath connection to a single server is not available.   
					- The Thin Provisioning function cannot be used.   
					- The Flexible Tier function cannot be used.   
					• Fujitsu recommends that the dual-controller types, in which the controller and I/O module are duplicated,   
					be used in a system where a high level of reliability is required.   
					■ External views of a 2.5" type controller enclosure   
					● Front view   
					Figure 1.1 Front view of a 2.5" type controller enclosure   
					2.5" disk or 2.5" Solid State Drive (SSD)   
					11   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
					 
				Chapter 1 Hardware Configurations   
					1.1 Controller Enclosure   
					● Rear view   
					• Single-controller type   
					Figure 1.2 Rear view of a 2.5" type controller enclosure (single-controller type)   
					Host interface (CA#1)   
					LAN (RMT) port LAN (MNT) port   
					Controller (CM#0)   
					PWC port   
					Cover   
					Power supply unit (PSU#0)   
					Drive interface (OUT) port   
					Power supply unit (PSU#1)   
					Host interface (CA#0)   
					• Dual-controller type   
					Figure 1.3 Rear view of a 2.5" type controller enclosure (dual-controller type)   
					Host interface (CA#1)   
					Host interface (CA#1)   
					LAN (RMT) port LAN (MNT) port   
					Controller (CM#1)   
					PWC port   
					LAN (RMT) port LAN (MNT) port   
					Controller (CM#0)   
					PWC port   
					Power supply unit (PSU#0)   
					Power supply unit (PSU#1)   
					Drive interface (OUT) port   
					Host interface (CA#0)   
					Drive interface (OUT) port   
					Host interface (CA#0)   
					12   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
				Chapter 1 Hardware Configurations   
					1.1 Controller Enclosure   
					● Top view   
					Figure 1.4 Top view of a 2.5" type controller enclosure   
					● Side view   
					Figure 1.5 Side view of a 2.5" type controller enclosure   
					■ External views of a 3.5" type controller enclosure   
					● Front view   
					Figure 1.6 Front view of a 3.5" type controller enclosure   
					3.5" disk or 3.5" Solid State Drive (SSD)   
					13   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
				Chapter 1 Hardware Configurations   
					1.1 Controller Enclosure   
					● Rear view   
					• Single-controller type   
					Figure 1.7 Rear view of a 3.5" type controller enclosure (single-controller type)   
					Host interface (CA#1)   
					LAN (RMT) port LAN (MNT) port   
					Controller (CM#0)   
					PWC port   
					Cover   
					Power supply unit (PSU#0)   
					Drive interface (OUT) port   
					Power supply unit (PSU#1)   
					Host interface (CA#0)   
					• Dual-controller type   
					Figure 1.8 Rear view of a 3.5" type controller enclosure (dual-controller type)   
					Host interface (CA#1)   
					Host interface (CA#1)   
					LAN (RMT) port LAN (MNT) port   
					Controller (CM#1)   
					PWC port   
					LAN (RMT) port LAN (MNT) port   
					Controller (CM#0)   
					PWC port   
					Power supply unit (PSU#0)   
					Power supply unit (PSU#1)   
					Drive interface (OUT) port   
					Host interface (CA#0)   
					Drive interface (OUT) port   
					Host interface (CA#0)   
					14   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
				Chapter 1 Hardware Configurations   
					1.1 Controller Enclosure   
					● Top view   
					Figure 1.9 Top view of a 3.5" type controller enclosure   
					● Side view   
					Figure 1.10 Side view of a 3.5" type controller enclosure   
					1.1.1   
					Controllers   
					The controller contains a CPU, cache memory, System Capacitor Unit (SCU), non-volatile memory, host   
					interfaces, drive interface ports, and LAN ports. The controller controls all operations in the ETERNUS DX Disk   
					storage system.   
					■ CPU   
					A single core processor is installed.   
					■ Cache memory   
					Cache memory enables high speed processing by storing frequently used data.   
					The cache memory capacity for each controller is 2GB for the ETERNUS DX80 S2 and 4GB for the ETERNUS DX90   
					S2.   
					15   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
				Chapter 1 Hardware Configurations   
					1.1 Controller Enclosure   
					■ Host interfaces   
					A host interface (CA) is a board that has interface ports to connect a controller to a server.   
					Up to two host interfaces can be installed in the controller of an ETERNUS DX Disk storage system. Different   
					types of host interfaces can exist together in the same controller. For details about the installation rules, refer   
					
					FC, iSCSI, FCoE, and SAS are available as host interface.   
					The following table shows the host interface specifications.   
					Table 1.1 Host interface specifications   
					Interface   
					Transfer speed (max.)   
					16Gbit/s   
					Connector type   
					Number of ports for each CA   
					FC   
					LC   
					2 
					8Gbit/s   
					iSCSI   
					10Gbit/s   
					LC   
					2 
					2 
					2 
					2 
					SFP+   
					(direct attach twinax copper)   
					1Gbit/s   
					RJ-45   
					LC   
					FCoE   
					SAS   
					10Gbit/s   
					SFP+   
					(direct attach twinax copper)   
					6Gbit/s   
					miniSAS (SFF-8088)   
					• FC and iSCSI host interfaces can be used as remote interfaces for remote connections by changing the port   
					mode. The port mode can be set from ETERNUS Web GUI or ETERNUS CLI.   
					• There are two types of iSCSI 10Gbit/s and FCoE host interfaces; an interface type with SFP+ modules (LC   
					connector for an FC cable connection) and an interface type without SFP+ modules (SPF+ connector for a   
					Copper Twinax cable connection).   
					• For SFP+ modules, Short Wave Length (SWL) or Long Wave Length (LWL) types can be installed in   
					16Gbit/s FC interfaces. The default modules that are installed in 16Gbit/s FC interfaces are SWL type SFP+   
					modules. To install LWL type SFP+ modules, purchase the Long wave SFP+ modules for the DX80 S2/DX90   
					S2 separately.   
					■ Drive interface ports   
					A drive interface port is used to connect drive enclosures.   
					The following table shows the drive interface port specifications.   
					Table 1.2 Drive interface port specifications for controllers   
					Interface   
					Transfer speed (max.)   
					6Gbit/s   
					Connector type   
					QSFP   
					Number of ports for each controller   
					1 
					SAS   
					16   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
				Chapter 1 Hardware Configurations   
					1.1 Controller Enclosure   
					■ LAN ports   
					Two LAN ports (RJ-45) are installed in each controller.   
					Each LAN port is used for operation management (MNT port) and for remote support function (RMT port)   
					respectively.   
					The following table shows the LAN port specifications.   
					Table 1.3 LAN port specifications for controllers   
					Transfer speed   
					(max.)   
					Number of ports   
					for each controller   
					Interface   
					Connector type   
					RJ-45   
					Ethernet   
					(1000Base-T/100Base-TX/10Base-T)   
					1Gbit/s   
					2 
					■ SCU   
					A System Capacitor Unit (SCU) is installed in a controller as a backup power source in case of power outage.   
					The SCU is charged from an external power source while the ETERNUS DX Disk storage system is running nor-   
					mally. If a power failure is detected, data in the cache memory is saved to the non-volatile memory in the con-   
					troller using the SCU. There is no limit to the post-failure data retention time.   
					■ PWC ports   
					A PWC port is installed in a controller.   
					The PWC port is used to connect a power synchronized unit to perform power synchronization.   
					The following table shows the PWC port specifications.   
					Table 1.4 PWC port specifications   
					Interface   
					Connector type   
					PWC   
					Number of ports for each controller   
					1 
					RS232C   
					1.1.2   
					Power Supply Units   
					The power supply unit transforms input AC power from a power socket to DC power and supplies power to each   
					component. Two power supply units are installed in each controller enclosure.   
					Each power supply unit contains fans.   
					17   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
				Chapter 1 Hardware Configurations   
					1.2 Drive Enclosures   
					1.2   
					Drive Enclosures   
					This section explains the main components in the drive enclosure.   
					The drive enclosure contains drives installed in the front, and I/O modules and power supply units in the rear.   
					Up to 24 drives can be installed in a 2.5" type drive enclosure. Up to 12 drives can be installed in a 3.5" type   
					drive enclosure.   
					Since the power supply units are redundant, operations can continue even if one of them fails.   
					When a drive enclosure is connected, a DE-ID (drive enclosure number) is automatically allocated.   
					■ External views of a 2.5" type drive enclosure   
					● Front view   
					Figure 1.11 Front view of a 2.5" type drive enclosure   
					2.5" disk or 2.5" Solid State Drive (SSD)   
					DE-ID display panel   
					● Rear view   
					• Single-IOM type   
					Figure 1.12 Rear view of a drive enclosure (single-IOM type)   
					Drive interface (OUT) port   
					Drive interface (IN) port   
					I/O module   
					(IOM6#0)   
					Cover   
					Power supply   
					unit (PSU#1)   
					Power supply unit (PSU#0)   
					18   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
				Chapter 1 Hardware Configurations   
					1.2 Drive Enclosures   
					• Dual-IOM type   
					Figure 1.13 Rear view of a drive enclosure (dual-IOM type)   
					Drive interface (OUT) port   
					Drive interface (IN) port   
					Drive interface (OUT) port   
					Drive interface (IN) port   
					I/O module   
					(IOM6#0)   
					I/O module   
					(IOM6#1)   
					Power supply   
					unit (PSU#1)   
					Power supply unit (PSU#0)   
					● Top view   
					Figure 1.14 Top view of a 2.5" type drive enclosure   
					● Side view   
					Figure 1.15 Side view of a 2.5" type drive enclosure   
					19   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
				Chapter 1 Hardware Configurations   
					1.2 Drive Enclosures   
					■ External views of a 3.5" type drive enclosure   
					● Front view   
					Figure 1.16 Front view of a 3.5" type drive enclosure   
					3.5" disk or 3.5" Solid State Drive (SSD)   
					DE-ID display panel   
					● Rear view   
					• Single-IOM type   
					Figure 1.17 Rear view of a drive enclosure (single-IOM type)   
					Drive interface (OUT) port   
					Drive interface (IN) port   
					I/O module   
					(IOM6#0)   
					Cover   
					Power supply   
					unit (PSU#1)   
					Power supply unit (PSU#0)   
					• Dual-IOM type   
					Figure 1.18 Rear view of a drive enclosure (dual-IOM type)   
					Drive interface (OUT) port   
					Drive interface (IN) port   
					Drive interface (OUT) port   
					Drive interface (IN) port   
					I/O module   
					(IOM6#0)   
					I/O module   
					(IOM6#1)   
					Power supply   
					unit (PSU#1)   
					Power supply unit (PSU#0)   
					20   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
				Chapter 1 Hardware Configurations   
					1.2 Drive Enclosures   
					● Top view   
					Figure 1.19 Top view of a 3.5" type drive enclosure   
					● Side view   
					Figure 1.20 Side view of a 3.5" type drive enclosure   
					1.2.1   
					I/O Modules   
					The I/O module is a component that controls the interaction between the controller and the drives.   
					The I/O module is connected to the controller or an I/O module on another drive enclosure.   
					■ Drive interface ports   
					A drive interface port is used to connect a controller enclosure or drive enclosures.   
					The drive interface port has an IN port and an OUT port.   
					The following table shows the drive interface port specifications.   
					Table 1.5 Drive interface port specifications for I/O modules   
					Interface   
					Transfer speed (max.)   
					6Gbit/s   
					Connector type   
					QSFP   
					Number of ports for each I/O module   
					1 (IN)   
					1 (OUT)   
					SAS   
					21   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
					 
				Chapter 1 Hardware Configurations   
					1.3 Enclosure Connection Path   
					1.2.2   
					Power Supply Units   
					The power supply unit transforms input AC power from a power socket to DC power and supplies power to each   
					component. Two power supply units are installed in each drive enclosure.   
					Each power supply unit contains fans.   
					1.3   
					Enclosure Connection Path   
					For a dual-controller type, a controller enclosure (CE) is connected to drive enclosures (DE) with multiple   
					paths.   
					A drive enclosure has two independent drive interface ports. Path redundancy is maintained by connecting   
					the drive enclosure to two controllers directly. This configuration allows operation to continue even if one of   
					the connection paths fails.   
					Up to nine drive enclosures can be connected to a controller enclosure as shown in the figures below.   
					Figure 1.21 Enclosure connection path (dual-controller type)   
					DE #09   
					DI   
					DI   
					DE #0x   
					DE #02   
					DI   
					DI   
					DI   
					DI   
					DI   
					DI   
					DI   
					DI   
					DE #01   
					CE   
					DI   
					DI   
					DI: Drive interface port   
					22   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
				Chapter 1 Hardware Configurations   
					1.4 Drives   
					A connection path is not duplicated in a single-controller type.   
					Figure 1.22 Enclosure connection path (single-controller type)   
					DE #09   
					DI   
					DE #0x   
					DI   
					DE #02   
					DI   
					DI   
					DE #01   
					DI   
					DI   
					CE   
					DI: Drive interface port   
					1.4   
					Drives   
					The following drives can be installed in a controller enclosure and drive enclosure.   
					1.4.1   
					2.5" Drives   
					The following table shows the 2.5" drive specifications.   
					Table 1.6 2.5" drive specifications   
					Drive name   
					SAS disks   
					Drive interface   
					Storage media   
					Hard disk   
					Storage capacity   
					300GB   
					Speed   
					15,000rpm   
					10,000rpm   
					300GB, 450GB, 600GB,   
					900GB   
					SAS self encrypting   
					disks (SEDs)   
					Serial Attached   
					SCSI (6Gbit/s)   
					Hard disk   
					300GB, 450GB, 600GB,   
					900GB   
					10,000rpm   
					Nearline SAS disks   
					SSDs   
					Hard disk   
					1TB   
					7,200rpm   
					– 
					Flash memory   
					100GB, 200GB, 400GB,   
					800GB   
					23   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
					 
				Chapter 1 Hardware Configurations   
					1.5 Power Distribution Units (Only for Regions Other than EMEA&I)   
					1.4.2   
					3.5" Drives   
					The following table shows the 3.5" drive specifications.   
					Table 1.7 3.5" drive specifications   
					Drive name   
					SAS disks   
					Drive interface   
					Storage media   
					Hard disk   
					Storage capacity   
					300GB, 450GB, 600GB   
					1TB, 2TB, 3TB, 4TB   
					Speed   
					15,000rpm   
					7,200rpm   
					– 
					Nearline SAS disks   
					SSDs   
					Serial Attached   
					SCSI (6Gbit/s)   
					Hard disk   
					Flash memory   
					100GB, 200GB, 400GB,   
					800GB   
					1.5   
					Power Distribution Units (Only for Regions Other than   
					EMEA&I)   
					There are two sizes for power distribution units: 1U and 2U.   
					A power distribution unit is an option to connect power supply units to power outlets when power sockets are   
					limited.   
					■ Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 1U, Max 2 enclosures   
					connection)   
					There are four outlets and two inlets.   
					Figure 1.23 Power distribution unit (AC200-240V, 1U, Max 2 enclosures connection)   
					Outlets (OUTPUT)   
					Inlets (INPUT)   
					24   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
					 
				Chapter 1 Hardware Configurations   
					1.5 Power Distribution Units (Only for Regions Other than EMEA&I)   
					The following table shows the specifications of a power distribution unit and the AC cables that are provided.   
					Table 1.8 Power distribution unit (AC200-240V, 1U, Max 2 enclosures connection) and provided AC cable   
					specifications   
					Item   
					Specifications   
					Power   
					Voltage   
					AC200 - 240V   
					Single   
					Phase   
					Frequency   
					Connection type   
					Length   
					50Hz/60Hz   
					Input cable   
					Output cable   
					IEC60320-C13 ↔ NEMA L6-15P   
					4m   
					Quantity   
					2 
					Connection type   
					Length   
					IEC60320-C13 ↔ IEC60320-C14   
					3m   
					4 
					Quantity   
					■ Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 6 enclosures   
					connection)   
					There are 12 outlets.   
					Figure 1.24 Power distribution unit (AC200-240V, 2U, Max 6 enclosures connection)   
					Outlets (OUTPUT)   
					The following table shows the specifications of a power distribution unit and the AC cables that are provided.   
					Table 1.9 Power distribution unit (AC200-240V, 2U, Max 6 enclosures connection) and provided AC cable   
					specifications   
					Item   
					Specifications   
					Power   
					Voltage   
					AC200 - 240V   
					Single   
					Phase   
					Frequency   
					Connection type   
					Length   
					50Hz/60Hz   
					Input cable   
					Output cable   
					Straight-through ↔ NEMA L6-20P   
					4m   
					Quantity   
					2 
					Connection type   
					Length   
					IEC60320-C13 ↔ IEC60320-C14   
					3m   
					12   
					Quantity   
					25   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
				Chapter 1 Hardware Configurations   
					1.5 Power Distribution Units (Only for Regions Other than EMEA&I)   
					■ Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 8 enclosures   
					connection)   
					There are 16 outlets.   
					Figure 1.25 Power distribution unit (AC200-240V, 2U, Max 8 enclosures connection)   
					Outlets (OUTPUT)   
					The following table shows the specifications of a power distribution unit and the AC cables that are provided.   
					Table 1.10 Power distribution unit (AC200-240V, 2U, Max 8 enclosures connection) and provided AC cable   
					specifications   
					Item   
					Specifications   
					Power   
					Voltage   
					AC200 - 240V   
					Single   
					Phase   
					Frequency   
					Connection type   
					Length   
					50Hz/60Hz   
					Input cable   
					Output cable   
					Straight-through ↔ NEMA L6-30P   
					4m   
					Quantity   
					2 
					Connection type   
					Length   
					IEC60320-C13 ↔ IEC60320-C14   
					3m   
					16   
					Quantity   
					26   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
				Chapter 2   
					ETERNUS DX Disk Storage System Installation   
					This chapter explains the installation of the ETERNUS DX Disk storage system.   
					2.1   
					Installation Specifications   
					2.1.1   
					ETERNUS DX80 S2   
					The following table shows the specifications of the ETERNUS DX80 S2.   
					Table 2.1 ETERNUS DX80 S2 installation specifications   
					ETERNUS DX80 S2   
					Item   
					2.5" drive configuration   
					482 × 645 × 88mm (2U)   
					482 × 540 × 88mm (2U)   
					435 × 148 × 38mm   
					(485 × 280 × 43mm) × 2 (*1)   
					35kg   
					3.5" drive configuration   
					482 × 670 × 88mm (2U)   
					482 × 555 × 88mm (2U)   
					Controller enclosure   
					Drive enclosure   
					Dimensions   
					(W × D × H)   
					1U   
					2U   
					Power   
					distribution unit   
					Controller enclosure   
					Drive enclosure   
					35kg   
					Maximum   
					weight (*2)   
					1U   
					2U   
					2kg   
					Power   
					distribution unit   
					(6kg) × 2 (*1)   
					Service area   
					Front: 800mm, Rear: 800mm   
					AC 100 – 120V, AC 200 – 240V   
					Single   
					Voltage   
					Phase   
					Frequency   
					50Hz/60Hz   
					Number of power supply units   
					2 (for each enclosure)   
					For AC200V connections:   
					IEC60320-C14G (supplied as standard)   
					Power   
					EMEA&I region   
					For AC200V connections:   
					Plug type   
					Regions other   
					than EMEA&I   
					NEMA L6-15P (supplied as standard)   
					For AC100V/AC200V connections:   
					IEC60320-C14 (optional)   
					AC 100 – 120V   
					AC 200 – 240V   
					AC 100 – 120V   
					AC 200 – 240V   
					630W (640VA)   
					630W (640VA)   
					570W (580VA)   
					570W (580VA)   
					620W (630VA)   
					Controller   
					enclosure   
					Maximum power   
					requirements   
					(*2)   
					610W (620VA)   
					550W (560VA)   
					550W (560VA)   
					Drive   
					enclosure   
					27   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
					 
					 
					 
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.1 Installation Specifications   
					ETERNUS DX80 S2   
					2.5" drive configuration 3.5" drive configuration   
					Item   
					AC 100 – 120V   
					AC 200 – 240V   
					AC 100 – 120V   
					AC 200 – 240V   
					2300kJ/h   
					2300kJ/h   
					2100kJ/h   
					2100kJ/h   
					2300kJ/h   
					2200kJ/h   
					2000kJ/h   
					2000kJ/h   
					Controller   
					enclosure   
					Maximum heat   
					generation (*2)   
					Drive   
					enclosure   
					3 
					Maximum   
					amount of   
					exhaust air   
					Controller enclosure   
					Drive enclosure   
					4.0m /min   
					3 
					4.0m /min   
					Operating   
					Not operating   
					Shipping   
					10 – 40°C   
					Temperature   
					0 – 50°C   
					-40 – 60°C   
					15°C/Hr or less   
					20 – 80%RH   
					8 – 80%RH   
					8 – 90%RH   
					30%/day or less   
					29°C   
					Temperature gradient   
					Operating   
					Humidity   
					Not operating   
					Shipping   
					Humidity gradient   
					Maximum wet bulb temperature   
					Altitude above sea level   
					Airborne dust   
					Environmental   
					conditions   
					0 – 3000m   
					3 
					0.15mg/m or less   
					Cl2: 3.4ppb or less, H2S: 7.1ppb or less   
					SO2: 37ppb or less, NH3: 420ppb or less   
					NO2: 52ppb or less, O3: 5ppb or less   
					HCl: 6.6ppb or less, HF: 3.6ppb or less   
					Gas concentration tolerance level   
					3 
					Oil vapor   
					0.2mg/m or less   
					If the ETERNUS DX Disk storage system is installed on the   
					ocean or premises within 0.5km from the coast, necessary   
					measures must be taken to prevent salt corrosion.   
					Seawater (salt corrosion)   
					Operating   
					400gal   
					1000gal   
					49dB (A)   
					6.6B   
					Vibration limit   
					Not operating   
					Sound Pressure Level (LpAm)   
					Sound Power Level (LWAd)   
					Noise emission   
					(*3)   
					*1: A 2U power distribution unit is composed of two 1U power distribution units.   
					*2: These values are for when each enclosure has twenty-four drives in a 2.5" drive configuration or when each enclo-   
					sure has twelve drives in a 3.5" drive configuration.   
					*3: These values are measured when a single controller enclosure and drive enclosure are configured in an environment   
					in which the temperature is 23 ± 2°C.   
					28   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.1 Installation Specifications   
					2.1.2   
					ETERNUS DX90 S2   
					The following table shows the specifications of the ETERNUS DX90 S2.   
					Table 2.2 ETERNUS DX90 S2 installation specifications   
					ETERNUS DX90 S2   
					2.5" drive configuration 3.5" drive configuration   
					Item   
					Controller enclosure   
					Drive enclosure   
					482 × 645 × 88mm (2U)   
					482 × 540 × 88mm (2U)   
					435 × 148 × 38mm   
					(485 × 280 × 43mm) × 2 (*1)   
					35kg   
					482 × 670 × 88mm (2U)   
					482 × 555 × 88mm (2U)   
					Dimensions   
					(W × D × H)   
					1U   
					2U   
					Power   
					distribution unit   
					Controller enclosure   
					Drive enclosure   
					35kg   
					Maximum   
					weight (*2)   
					1U   
					2U   
					2kg   
					Power   
					distribution unit   
					(6kg) × 2 (*1)   
					Service area   
					Front: 800mm, Rear: 800mm   
					AC 100 – 120V, AC 200 – 240V   
					Single   
					Voltage   
					Phase   
					Frequency   
					50Hz/60Hz   
					Number of power supply units   
					2 (for each enclosure)   
					For AC200V connections:   
					IEC60320-C14G (supplied as standard)   
					Power   
					EMEA&I region   
					For AC200V connections:   
					Plug type   
					Regions other   
					than EMEA&I   
					NEMA L6-15P (supplied as standard)   
					For AC100V/AC200V connections:   
					IEC60320-C14 (optional)   
					AC 100 – 120V   
					AC 200 – 240V   
					AC 100 – 120V   
					AC 200 – 240V   
					AC 100 – 120V   
					AC 200 – 240V   
					AC 100 – 120V   
					AC 200 – 240V   
					630W (640VA)   
					630W (640VA)   
					570W (580VA)   
					570W (580VA)   
					2300kJ/h   
					620W (630VA)   
					Controller   
					enclosure   
					Maximum power   
					requirements   
					(*2)   
					610W (620VA)   
					550W (560VA)   
					550W (560VA)   
					2300kJ/h   
					Drive   
					enclosure   
					Controller   
					enclosure   
					2300kJ/h   
					2200kJ/h   
					Maximum heat   
					generation (*2)   
					2100kJ/h   
					2000kJ/h   
					Drive   
					enclosure   
					2100kJ/h   
					2000kJ/h   
					3 
					Maximum   
					amount of   
					exhaust air   
					Controller enclosure   
					Drive enclosure   
					4.0m /min   
					3 
					4.0m /min   
					29   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.1 Installation Specifications   
					ETERNUS DX90 S2   
					2.5" drive configuration 3.5" drive configuration   
					Item   
					Operating   
					Not operating   
					Shipping   
					10 – 40°C   
					Temperature   
					0 – 50°C   
					-40 – 60°C   
					15°C/Hr or less   
					20 – 80%RH   
					8 – 80%RH   
					8 – 90%RH   
					30%/day or less   
					29°C   
					Temperature gradient   
					Operating   
					Humidity   
					Not operating   
					Shipping   
					Humidity gradient   
					Maximum wet bulb temperature   
					Altitude above sea level   
					Airborne dust   
					Environmental   
					conditions   
					0 – 3000m   
					3 
					0.15mg/m or less   
					Cl2: 3.4ppb or less, H2S: 7.1ppb or less   
					SO2: 37ppb or less, NH3: 420ppb or less   
					NO2: 52ppb or less, O3: 5ppb or less   
					HCl: 6.6ppb or less, HF: 3.6ppb or less   
					Gas concentration tolerance level   
					3 
					Oil vapor   
					0.2mg/m or less   
					If the ETERNUS DX Disk storage system is installed on the   
					ocean or premises within 0.5km from the coast, necessary   
					measures must be taken to prevent salt corrosion.   
					Seawater (salt corrosion)   
					Operating   
					400gal   
					1000gal   
					49dB (A)   
					6.6B   
					Vibration limit   
					Not operating   
					Sound Pressure Level (LpAm)   
					Sound Power Level (LWAd)   
					Noise emission   
					(*3)   
					*1: A 2U power distribution unit is composed of two 1U power distribution units.   
					*2: These values are for when each enclosure has twenty-four drives in a 2.5" drive configuration or when each enclo-   
					sure has twelve drives in a 3.5" drive configuration.   
					*3: These values are measured when a single controller enclosure and drive enclosure are configured in an environment   
					in which the temperature is 23 ± 2°C.   
					30   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.2 Storage System Dimensions   
					2.2   
					Storage System Dimensions   
					2.2.1   
					Controller Enclosure Dimensions   
					■ 2.5" type controller enclosure   
					The following diagrams show the dimensions of a 2.5" type controller enclosure.   
					The dimension values do not include any protruding parts (approximation).   
					Figure 2.1 2.5" type controller enclosure dimensions   
					Side   
					482mm   
					Top   
					Front   
					31   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.2 Storage System Dimensions   
					■ 3.5" type controller enclosure   
					The following diagrams show the dimensions of a 3.5" type controller enclosure.   
					The dimension values do not include any protruding parts (approximation).   
					Figure 2.2 3.5" type controller enclosure dimensions   
					Side   
					482mm   
					Top   
					Front   
					32   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.2 Storage System Dimensions   
					2.2.2   
					Drive Enclosure Dimensions   
					■ 2.5" type drive enclosure   
					The following diagrams show the dimensions of a 2.5" type drive enclosure.   
					The dimension values do not include any protruding parts (approximation).   
					Figure 2.3 2.5" type drive enclosure dimensions   
					Side   
					482mm   
					Top   
					Front   
					33   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.2 Storage System Dimensions   
					■ 3.5" type drive enclosure   
					The following diagrams show the dimensions of a 3.5" type drive enclosure.   
					The dimension values do not include any protruding parts (approximation).   
					Figure 2.4 3.5" type drive enclosure dimensions   
					Side   
					482mm   
					Top   
					Front   
					34   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.3 Package Size   
					2.3   
					Package Size   
					The ETERNUS DX Disk storage system is shipped in cardboard boxes. These boxes may not fit through some   
					doorways or elevators. To make sure that the ETERNUS DX Disk storage system can be moved to the   
					installation site, carefully check the transport route information. Refer to "2.1 Installation Specifications"   
					(page 27) for the maximum weight of each enclosure.   
					The following table shows the package size and the maximum package weight of each component for regions   
					other than EMEA&I.   
					Table 2.3 Package size (for regions other than EMEA&I)   
					Component   
					Controller enclosure   
					Package size (W × D × H)   
					600 × 760 × 240mm   
					Maximum weight (approx.)   
					40kg   
					2.5" type   
					3.5" type   
					2.5" type   
					3.5" type   
					2.5"   
					600 × 780 × 240mm   
					600 × 660 × 240mm   
					600 × 670 × 240mm   
					160 × 278 × 106mm   
					189 × 300 × 116mm   
					570 × 710 × 160mm   
					(390 × 590 × 180mm) × 2   
					40kg   
					40kg   
					Drive enclosure   
					Drive (*1)   
					40kg   
					0.5kg   
					1.0kg   
					4kg   
					3.5"   
					1U   
					Power distribution unit   
					2U   
					(7kg) × 2   
					*1: When an order for optional drives to be installed in the factory is placed, enclosures are shipped with the drives   
					preinstalled. When optional drives are ordered without preinstallation, each drive is shipped in an individual   
					package.   
					35   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.4 Installation Area   
					2.4   
					Installation Area   
					This section explains the installation area and the service area that are required for an ETERNUS DX Disk   
					storage system that is installed in a Fujitsu 19-inch rack.   
					Secure service areas that are 800mm or more in the front and rear of the ETERNUS DX Disk storage system.   
					The size of the side areas varies depending on the rack specifications.   
					Figure 2.5 Installation area and service area   
					800mm or more   
					Rear service area   
					ETERNUS DX   
					Disk storage system   
					800mm or more   
					Front service area   
					2.5   
					Installation Environment   
					Sufficient consideration of the installation environment should be taken to ensure proper use of the ETERNUS   
					DX Disk storage system. Using the ETERNUS DX Disk storage system in an environment that does not satisfy   
					the installation environment requirements may cause a failure to occur with the ETERNUS DX Disk storage   
					system.   
					2.5.1   
					Air Conditioning   
					It is important to consider the flows of cooling air (intake air) and exhaust air for the installation location. The   
					temperature in some ETERNUS DX Disk storage systems may rise when exhaust air is taken in from other   
					ETERNUS DX Disk storage systems. In addition, check other factors that might affect the usage environment   
					temperature, such as the room size, whether other ETERNUS DX Disk storage systems are installed, and how   
					many people are present in the room.   
					When installing air conditioning, the ambient temperature should be considered.   
					36   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
					 
					 
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.6 Outlet/Socket Specifications   
					● Ambient temperature   
					An ETERNUS DX Disk storage system is cooled by taking in air through the front intakes and pushing out   
					the exhaust air through the rear of the ETERNUS DX Disk storage system. If the intake air temperature does   
					not meet the ambient environment conditions, a temperature error occurs and the power of the ETERNUS   
					DX Disk storage system is shut down.   
					- Front intake air temperature   
					Make sure that the front intake air temperature is between 10 and 40°C.   
					- Rear exhaust air temperature   
					For example, when the intake air temperature is 40°C, the exhaust air temperature is 50°C or higher.   
					The necessary cooling capacity of air conditioning must be checked.   
					Check the heat generation amount and the exhaust air amount that are listed in "2.1 Installation   
					Specifications" (page 27) to cool the exhaust air from the ETERNUS DX Disk storage system.   
					2.5.2   
					2.5.3   
					Earthquake Resistance   
					Take the necessary measures (e.g. secure the rack to the floor or wall) to prevent a rack in which an ETERNUS   
					DX Disk storage system is installed from falling down when earthquakes occur.   
					Earthquake countermeasures vary depending on the installation location, the floor conditions, and the type   
					of rack that is used. Contact your installation contractor for more details regarding earthquake   
					countermeasure methods and how work should be conducted.   
					Load Bearing Capacity for Floors   
					Make sure that the following relationship between the load bearing capacity of the floor and the weight of   
					the ETERNUS DX Disk storage system is maintained.   
					(Load bearing capacity of the floor) > (ETERNUS DX Disk storage system weight ÷ Installation area that   
					includes service areas)   
					If the condition above is not satisfied, additional measures are required to ensure sufficient load bearing   
					capacity. Contact your installation contractor for details about the necessary measures that must be taken.   
					2.6   
					Outlet/Socket Specifications   
					Power can be supplied to the ETERNUS DX Disk storage system from two power sources because each   
					enclosure has two power supply units.   
					During normal operation, each of the power sources supplies half of the necessary power.   
					When one of the power supply lines fails, all of the necessary power is supplied from only one power source.   
					Using the same power supply condition for all of the power supply units is recommended so that different   
					power supply conditions (such as whether power distribution units are used or not and input voltage) are not   
					used for the ETERNUS DX Disk storage system.   
					This section explains the power connection specifications of the ETERNUS DX Disk storage systems.   
					37   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
					 
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.6 Outlet/Socket Specifications   
					2.6.1   
					Specifications for Optional Power Supply Products   
					This section explains the specifications of optional power cords and power related optional products.   
					When using power distribution units, the number of outlets that are required to connect the controller   
					enclosure and drive enclosures should be taken into consideration.   
					In addition, make sure that the plug type of the power distribution unit fits the power socket when using an   
					existing power socket. If the plug type does not fit the power socket, replace the socket.   
					■ Power cords   
					● Power cords supplied with the ETERNUS DX Disk storage system (for the EMEA&I region)   
					Table 2.4 Specifications for power cords supplied with the ETERNUS DX Disk storage system (for the   
					EMEA&I region)   
					Usage   
					Plug type   
					Socket type   
					Cable length   
					2.5m   
					Remarks   
					250V 10A   
					IEC60320-C14G   
					IEC60320-C13   
					Used for connection between the   
					ETERNUS DX Disk storage system   
					and the socket (IEC60320-C13 ↔   
					IEC60320-C14G)   
					● Power cords supplied with the ETERNUS DX Disk storage system (for regions other than EMEA&I)   
					Table 2.5 Specifications for power cords supplied with the ETERNUS DX Disk storage system (for regions   
					other than EMEA&I)   
					Usage   
					Plug type   
					Socket type   
					Cable length   
					4.0m   
					Remarks   
					250V 15A   
					(Normal usage   
					<12A)   
					NEMA L6-15P   
					NEMA L6-15R   
					Used for connection between the   
					ETERNUS DX Disk storage system   
					and the socket   
					(IEC60320-C13 ↔   
					NEMA L6-15P)   
					● Optional AC100V and AC200V power cords (for regions other than EMEA&I)   
					Optional power cords are used to connect devices with the IEC60320-C13 power socket type. These power   
					cords can be used to connect devices with the AC100V and AC200V specifications.   
					Table 2.6 Specifications for optional power cords (for regions other than EMEA&I)   
					Usage   
					Plug type   
					Socket type   
					Cable length   
					3.0m   
					Remarks   
					250V 10A   
					(Normal usage <8A)   
					Used for connection between the   
					ETERNUS DX Disk storage system   
					and the socket   
					IEC60320-C14   
					IEC60320-C13   
					(IEC60320-C13 ↔   
					IEC 60320-C14)   
					38   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
					 
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.6 Outlet/Socket Specifications   
					■ Power distribution units (only for regions other than EMEA&I)   
					● Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 1U, Max 2 enclosures connection)   
					Table 2.7 Specifications for power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 1U, Max 2   
					enclosures connection)   
					Output   
					Input   
					Remarks   
					250V 15A   
					Outlet type   
					IEC60320-C13   
					Plug type   
					Socket type   
					NEMA L6-15R   
					Cable length   
					4.0m   
					NEMA L6-15P   
					(Normal usage   
					<12A)   
					● Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 6 enclosures connection)   
					Table 2.8 Specifications for power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 6   
					enclosures connection)   
					Output   
					Input   
					Remarks   
					250V 20A   
					Outlet type   
					IEC60320-C13   
					Plug type   
					Socket type   
					NEMA L6-20R   
					Cable length   
					4.0m   
					NEMA L6-20P   
					(Normal usage   
					<16A)   
					● Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 8 enclosures connection)   
					Table 2.9 Specifications for power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 8   
					enclosures connection)   
					Output   
					Input   
					Remarks   
					250V 30A   
					Outlet type   
					IEC60320-C13   
					Plug type   
					Socket type   
					NEMA L6-30R   
					Cable length   
					4.0m   
					NEMA L6-30P   
					(Normal usage   
					<24A)   
					39   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.6 Outlet/Socket Specifications   
					2.6.2   
					Required Number of Outlets/Sockets   
					The number of power outlets/sockets required to install the ETERNUS DX Disk storage system depends on the   
					number of drive enclosures and power distribution units.   
					It is recommended that the power cords of the drive enclosures are connected to the power distribution units   
					that are installed in the same rack. Secure the necessary number of power outlets within the same rack to   
					avoid connecting power cords to power outlets in different racks. It may be necessary to purchase additional   
					power distribution units depending on the installation locations of enclosures.   
					■ Without power distribution units   
					Two power sockets are required for each enclosure (controller enclosure and drive enclosure).   
					■ With power distribution units   
					Two power sockets are required for each power distribution unit. There are three types of power distribution   
					units. The size and number of outlets are different for each type.   
					Table 2.10 Required number of outlets and sockets to install power distribution units   
					Product name   
					Number of outlets   
					4 
					Number of sockets   
					2 
					Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 1U, Max 2   
					enclosures connection)   
					Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 6   
					enclosures connection)   
					12   
					16   
					2 
					2 
					Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 8   
					enclosures connection)   
					● Power distribution unit (1U)   
					Up to two enclosures can be connected to a single power distribution unit (1U).   
					Figure 2.6 Power distribution unit (1U)   
					Output (4 outlets)   
					Input (2 sockets)   
					40   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.7 Circuit Protectors   
					● Power distribution unit (2U)   
					- Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 6 enclosures connection)   
					Up to six enclosures can be connected.   
					- Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 2U, Max 8 enclosures connection)   
					Up to eight enclosures can be connected.   
					Figure 2.7 Power distribution unit (2U)   
					Input (2 sockets)   
					Output (12 or 16 outlets)   
					2.7   
					Circuit Protectors   
					Protection coordination must be secured between the distribution board circuit protectors and the ETERNUS   
					DX Disk storage system or power distribution units to protect the ETERNUS DX Disk storage system by blocking   
					the failed circuit immediately when a power supply input error occurs.   
					Distribution board circuit protectors must satisfy the following required conditions and breaking   
					characteristics.   
					■ Required conditions   
					The distribution board circuit protectors must satisfy the required conditions that are listed in Table 2.11.   
					Table 2.11 Required conditions for distribution board circuit protectors   
					Current capacity   
					Power supply   
					Connected device   
					Regions other   
					than EMEA&I   
					voltage   
					EMEA&I region   
					Power distribution unit for DX80 S2/DX90 S2 (AC200-   
					240V, 1U, Max 2 enclosures connection)   
					AC200 – 240V   
					AC200 – 240V   
					AC200 – 240V   
					15A   
					20A   
					30A   
					15A   
					— 
					— 
					Power distribution unit for DX80 S2/DX90 S2 (AC200-   
					240V, 2U, Max 6 enclosures connection)   
					Power distribution unit for DX80 S2/DX90 S2 (AC200-   
					240V, 2U, Max 8 enclosures connection)   
					— 
					ETERNUS DX Disk storage system   
					(without power distribution units)   
					AC100 – 120V   
					AC200 – 240V   
					16A   
					41   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.7 Circuit Protectors   
					■ Breaking characteristics   
					The breaking characteristics (*1) of distribution board circuit protectors must be equivalent to or slower than   
					
					*1: Relationship between the size of excess current and operation time   
					Figure 2.8 Breaking characteristics of distribution board circuit protectors   
					180   
					120   
					60   
					40   
					20   
					10   
					6 
					4 
					2 
					1 
					40   
					20   
					10   
					6 
					4 
					2 
					1 
					0.6   
					0.4   
					0.2   
					B 
					C 
					D 
					0.1   
					~ 
					~ 
					~ 
					0.06   
					0.04   
					0.02   
					0.01   
					1 
					1.5 2   
					3 
					4 
					5 
					6 7 8 10 15 20 30 40 50 80 100   
					Current (ratio for the current rating)   
					42   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.7 Circuit Protectors   
					■ Connection diagrams   
					The following diagrams show connections between the power distribution units, the ETERNUS DX Disk storage   
					system, and the power sockets of the distribution boards.   
					● For power distribution unit (1U) connection   
					The following diagram shows a power supply connection example when a power distribution unit for DX80   
					S2/DX90 S2 (AC200-240V, 1U, Max 2 enclosures connection) is used.   
					Figure 2.9 Example of a power supply connection using a power distribution unit (1U)   
					ETERNUS DX Disk storage system   
					DE #01   
					CE   
					CP   
					CP   
					Power distribution unit   
					Line 0   
					Line 1   
					CP   
					Distribution   
					board   
					CP   
					Distribution   
					board   
					To power supply facility   
					To power supply facility   
					CP: Circuit Protector   
					43   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.7 Circuit Protectors   
					● For power distribution unit (2U) connection   
					The following diagram shows a power supply connection example when a power distribution unit for DX80   
					S2/DX90 S2 (AC200-240V, 2U, Max 6 enclosures connection) or a power distribution unit for DX80 S2/DX90   
					S2 (AC200-240V, 2U, Max 8 enclosures connection) is used.   
					Figure 2.10 Example of a power supply connection using a power distribution unit (2U)   
					ETERNUS DX Disk storage system   
					DE #xx   
					...   
					DE #00   
					CE   
					CP   
					CP   
					CP   
					CP   
					Power distribution unit   
					Line 0   
					Line 1   
					CP   
					Distribution   
					CP   
					Distribution   
					board   
					board   
					To power supply facility   
					To power supply facility   
					CP: Circuit Protector   
					44   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				Chapter 2 ETERNUS DX Disk Storage System Installation   
					2.7 Circuit Protectors   
					● For direct (no power distribution unit) connection   
					The following diagram shows a power supply connection example when no power distribution units are   
					used.   
					Figure 2.11 Example of a power supply connection without power distribution units   
					ETERNUS DX Disk storage system   
					DE #02   
					CP   
					CP   
					DE #01   
					CE   
					Line 0   
					Line 1   
					CP: Circuit Protector   
					Do   
					CAUTION   
					• Only connect the ETERNUS DX Disk storage system to circuit protectors.   
					45   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				Chapter 3   
					Connections   
					This chapter explains connections for the ETERNUS DX Disk storage system.   
					3.1   
					Host Connections   
					FC, iSCSI, FCoE, and SAS are available as host interfaces. The server and the ETERNUS DX Disk storage system   
					can be connected directly or via a switch.   
					3.1.1   
					Host Interfaces   
					This section describes each host interface.   
					■ FC (Fibre Channel)   
					FC supports two connection topologies: Fibre Channel Arbitrated Loop (FC-AL) and Fabric. Direct connections   
					and switch connections to servers are available.   
					Two types of host interfaces with a maximum transfer speed of either 16Gbit/s or 8Gbit/s are available.   
					When FC switches are used, zoning should be set for the FC switches to ensure the security of data.   
					■ iSCSI   
					Direct connections and switch connections to servers are available. Two types of host interfaces with a   
					maximum transfer speed of either 10Gbit/s or 1Gbit/s are available.   
					In order to maintain iSCSI performance, the iSCSI network should be physically separated from other types of   
					networks (such as networks for Internet access and file transfers).   
					• CHAP   
					CHAP authentication can prevent unauthorized access. The following CHAP authentication methods are   
					supported:   
					- Unidirectional CHAP   
					- Bidirectional CHAP   
					46   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
					 
				Chapter 3 Connections   
					3.1 Host Connections   
					• Virtual Local Area Network (VLAN tagging)   
					The VLAN tagging function is supported. A tag (VLAN ID) can be used for each port.   
					When the ETERNUS DX Disk storage system is connected to multiple servers, use a LAN switch that has   
					the VLAN function and allocate a separate segment to each server so that security can be maintained.   
					• Jumbo Frame   
					Enabling Jumbo Frame makes data transfer more efficient by increasing the amount of data that can be   
					transferred for each Frame.   
					Table 3.1 Ethernet frame capacity (Jumbo Frame settings)   
					Jumbo Frame settings   
					Ethernet frame capacity   
					Up to 9000 bytes   
					Enabled   
					Disabled   
					Up to 1500 bytes   
					• Confirm that the connected device supports Jumbo Frame before enabling Jumbo Frame.   
					• Server-side CPU load can be reduced by using Jumbo Frame. However, I/O performance may be   
					reduced by 10% to 30%.   
					• Security Architecture for Internet Protocol (IPsec)   
					The IPsec function is not supported. Connect the server using a LAN switch that has the IPsec function as   
					required.   
					• Internet Protocol   
					IPv4 and IPv6 are supported.   
					IPv6 is supported in firmware version V10L35 or later.   
					■ FCoE   
					Fabric is supported as a connection topology. The maximum transfer speed is 10Gbit/s. When using an FCoE   
					interface, connect the ETERNUS DX Disk storage system to the FCoE switch. Direct connections to servers are   
					not supported.   
					• Perform zoning settings for FCoE switches.   
					• When an FCoE interface is used for the HBA of the server, use FCoE for the host interface of the ETERNUS   
					DX Disk storage system.   
					47   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				Chapter 3 Connections   
					3.1 Host Connections   
					■ SAS   
					Simple, cost effective, and high performance network storage environment can be configured.   
					Direct connections and switch connections to servers are available.   
					The maximum transfer speed is 6Gbit/s.   
					When SAS switches are used, zoning should be set for the SAS switches to ensure the security of data.   
					3.1.2   
					Host Connection Path   
					This section explains the connection configuration between server Host Bus Adapters (HBAs) and ETERNUS DX   
					Disk storage system host interface ports.   
					■ Single path configuration   
					A single path configuration connects the ETERNUS DX Disk storage system to a server via a single path.   
					The server cannot access an ETERNUS DX Disk storage system when a component (such as a controller, HBA,   
					switch, or cable) on the path has a problem. The system must be stopped during the replacement of failed   
					components and controller firmware.   
					In a single path connection configuration, the path failover and load balancing functions are not supported.   
					A multipath connection configuration is recommended to maintain availability when a problem occurs.   
					Figure 3.1 Single path connection (direct connection)   
					Server   
					Server   
					HBA   
					HBA   
					Port Port   
					CA   
					Port Port   
					CA   
					CM#0   
					CM#1   
					ETERNUS DX Disk storage system   
					48   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
				Chapter 3 Connections   
					3.1 Host Connections   
					Figure 3.2 Single path connection (switch connection)   
					Server   
					Server   
					Server   
					HBA   
					HBA   
					HBA   
					Switch   
					Port Port   
					CA   
					Port Port   
					CA   
					CM#0   
					CM#1   
					ETERNUS DX Disk storage system   
					■ Multipath configuration   
					A multipath configuration connects the ETERNUS DX Disk storage system to a server via multiple paths   
					(multipath). System reliability is improved due to the path redundancy. For multipath connections, driver   
					software to control multipathing is required.   
					If a path fails, access can continue by using the path failover function that switches access from the failed path   
					to another path. The performance of the system can be improved by using the load balancing function to   
					spread the access load over multiple paths.   
					Figure 3.3 Multipath connection (direct connection)   
					Server   
					Server   
					HBA   
					HBA   
					HBA   
					HBA   
					Port Port Port Port   
					CA CA   
					Port Port Port Port   
					CA CA   
					CM#0   
					CM#1   
					ETERNUS DX Disk storage system   
					49   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
				Chapter 3 Connections   
					3.1 Host Connections   
					Figure 3.4 Multipath connection (switch connection)   
					Server   
					Server   
					Server   
					HBA   
					HBA   
					HBA   
					HBA   
					HBA   
					HBA   
					Switch   
					Switch   
					Port Port   
					CA   
					Port Port   
					CA   
					CM#0   
					CM#1   
					ETERNUS DX Disk storage system   
					• When configuring multipathing for reliability, make sure to configure a redundant connection for the   
					controllers of the ETERNUS DX Disk storage system. Configure paths to connect to different controllers   
					(CM#0 and CM#1). Combinations of host interface numbers (CA#0 and CA#1) in controllers do not need   
					to be taken into consideration.   
					• Paths from a single server should be separately connected to a different host interface in case of host   
					interface failure.   
					■ Cluster configuration   
					When a server is duplicated in a cluster configuration and the ETERNUS DX Disk storage system is shared by   
					multiple servers, software to control the cluster configuration is required.   
					50   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				Chapter 3 Connections   
					3.1 Host Connections   
					■ Configurations that satisfy the system requirements   
					System requirements should be taken into consideration for a connection configuration between the HBAs on   
					the server and the host interface ports on the ETERNUS DX Disk storage system.   
					The following figure shows a connection configuration for availability:   
					Figure 3.5 Connection that satisfies the system requirements (for availability)   
					Server   
					Server   
					HBA   
					HBA   
					HBA   
					HBA   
					Port Port   
					CA#0   
					Port Port   
					CA#0   
					CM#0   
					CM#1   
					ETERNUS DX Disk storage system   
					The following figure shows a connection configuration for enhanced performance:   
					Figure 3.6 Connection that satisfies the system requirements (for enhanced performance)   
					Server   
					Server   
					HBA   
					HBA   
					HBA   
					HBA   
					Port Port Port Port   
					CA#0 CA#1   
					Port Port Port Port   
					CA#0 CA#1   
					CM#0   
					CM#1   
					ETERNUS DX Disk storage system   
					When the ETERNUS DX Disk storage system is accessed from both of the servers, performance can be secured   
					by connecting to the ETERNUS DX Disk storage system using one host interface port on each of the four host   
					interfaces.   
					51   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
				Chapter 3 Connections   
					3.2 Remote Connections   
					3.2   
					Remote Connections   
					An FC or iSCSI interface is available for a remote connection.   
					For remote connections, different types of interfaces (FC, iSCSI 10Gbit/s, iSCSI 1Gbit/s) cannot exist together   
					on a REC path (connection between a local ETERNUS DX Disk storage system and a remote ETERNUS DX Disk   
					storage system).   
					When different types of remote interfaces exist in the same ETERNUS DX Disk storage system, make sure to   
					use the same type of interface for each REC path.   
					For example, the following configuration is not supported because different types of interfaces (FC/iSCSI)   
					exist together on a REC path.   
					Figure 3.7 Example of non-supported connection configuration (when multiple types of remote interfaces   
					are installed in the same ETERNUS DX Disk storage system)   
					ETERNUS DX   
					Disk storage   
					system   
					ETERNUS DX   
					Disk storage   
					system   
					FC-RA   
					FC-RA   
					REC path   
					iSCSI-RA   
					iSCSI-RA   
					The following configuration is supported because the same type of interface is used for each REC path.   
					Figure 3.8 Example of supported connection configuration (when multiple types of remote interfaces are   
					installed in the same ETERNUS DX Disk storage system)   
					ETERNUS DX   
					Disk storage   
					system   
					ETERNUS DX   
					Disk storage   
					system   
					ETERNUS DX   
					Disk storage   
					system   
					FC-RA   
					FC-RA   
					FC-RA   
					iSCSI-RA   
					iSCSI-RA   
					iSCSI-RA   
					iSCSI-RA   
					REC path   
					REC path   
					FC-RA   
					52   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
				Chapter 3 Connections   
					3.2 Remote Connections   
					3.2.1   
					Remote Interfaces   
					This section describes each remote interface.   
					■ FC (Fibre Channel)   
					Data is transferred between multiple ETERNUS DX Disk storage systems by using host interfaces. The ETERNUS   
					DX Disk storage system can be connected to the destination storage system directly or via switch. A digital   
					service unit is required for a remote connection that is using a line. Two types of host interfaces with a   
					maximum transfer speed of either 16Gbit/s or 8Gbit/s are available.   
					Figure 3.9 FC connection for remote copy (redundant path)   
					ETERNUS DX Disk storage system   
					ETERNUS DX Disk storage system   
					FC switch   
					FC switch   
					FC-RA   
					Copy   
					source   
					FC-RA   
					Copy   
					destination   
					SAN (FC)   
					FC-RA   
					FC-RA   
					FC switch   
					FC switch   
					Figure 3.10 FC connection for remote copy (using lines)   
					ETERNUS DX Disk storage system   
					ETERNUS DX Disk storage system   
					Copy   
					destination   
					Copy   
					source   
					WAN (IP line)   
					FC-RA   
					FC-RA   
					Digital service unit   
					Digital service unit   
					■ iSCSI   
					Data is transferred between multiple ETERNUS DX Disk storage systems by using host interfaces. Direct   
					connection to a WAN is possible.   
					Two types of host interfaces with a maximum transfer speed of either 10Gbit/s or 1Gbit/s are available.   
					Figure 3.11 iSCSI connection for remote copy (using lines)   
					ETERNUS DX Disk storage system   
					ETERNUS DX Disk storage system   
					Copy   
					destination   
					Copy   
					source   
					WAN (IP line)   
					iSCSI-RA   
					iSCSI-RA   
					Switch   
					Switch   
					53   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
					 
				Chapter 3 Connections   
					3.2 Remote Connections   
					The IPsec function is not supported for iSCSI interfaces. To use the IPsec function when performing a remote   
					copy with the ETERNUS DX90 S2, the ETERNUS DX410 S2/DX440 S2, or the ETERNUS DX8100 S2/DX8700 S2,   
					use a LAN switch that has the IPsec function.   
					3.2.2   
					Connectable Models   
					Remote copy is available for the ETERNUS DX90 S2. The ETERNUS DX90 S2 can be connected to not only the   
					same model, it can also be connected to the ETERNUS DX410 S2/DX440 S2, the ETERNUS DX8100 S2/DX8700   
					S2, and older ETERNUS Disk storage system models. The following table shows the models that can be   
					connected and the interfaces that are available.   
					Table 3.2 Connectable models and available remote interfaces   
					Remote interface   
					Connectable model (*1)   
					FC   
					FC   
					iSCSI 10Gbit/s   
					iSCSI   
					16Gbit/s   
					8Gbit/s   
					1Gbit/s   
					ETERNUS DX90 S2   
					Available   
					Available   
					Available   
					Available   
					Available   
					Available   
					Available   
					Available   
					Available   
					Available   
					Available   
					Available   
					Available   
					ETERNUS DX410 S2/DX440 S2   
					ETERNUS DX8100 S2/DX8700 S2   
					Available   
					(*2)   
					ETERNUS DX90   
					— 
					— 
					— 
					— 
					— 
					— 
					— 
					— 
					— 
					— 
					ETERNUS DX410/DX440   
					ETERNUS DX8100/DX8400/DX8700   
					Available   
					(*2)   
					Available   
					Available   
					ETERNUS4000 models 400, 600   
					ETERNUS8000 models 800, 1200, 2200   
					Available   
					(*2)   
					ETERNUS4000 models 300, 500   
					ETERNUS8000 models 700, 900, 1100, 2100   
					Available   
					(*3)   
					Available   
					(*4)   
					Available   
					(*5) (*6)   
					Available   
					(*6)   
					ETERNUS6000   
					*1: Firmware upgrade may be required to connect to the ETERNUS DX90 S2. For information about firmware versions,   
					contact your sales representative.   
					*2: The transfer speed is 8Gbit/s or 4Gbit/s.   
					*3: The transfer speed is 4Gbit/s.   
					*4: The transfer speed is 4Gbit/s or 2Gbit/s.   
					*5: Connections are available via switches. Direct connections are not supported.   
					*6: The transfer speed is FC 2Gbit/s. Remote connections are available only when data is migrated.   
					Stack mode or Through mode can be used as the transfer mode.   
					54   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
				Chapter 3 Connections   
					3.3 LAN Connection   
					3.3   
					LAN Connection   
					The ETERNUS DX Disk storage system requires a LAN connection for operation management.   
					In addition, information such as ETERNUS DX Disk storage system failures is notified to the remote support   
					center.   
					Make sure to connect each controller to the LAN for operation management.   
					Figure 3.12 Example of a LAN connection   
					Administration terminal   
					SNMP   
					manager   
					- Operation   
					management/setting   
					- Wake On LAN   
					NTP server   
					Mail server   
					Authentication   
					server   
					Syslog server   
					Remote support   
					center   
					ETERNUS DX   
					Disk storage system   
					When using ETERNUS Web GUI to manage operations, prepare a Web browser in the administration terminal.   
					The following table shows the supported Web browsers.   
					Table 3.3 ETERNUS Web GUI operating environment   
					Software   
					Guaranteed operating environment   
					Web browser   
					Microsoft Internet Explorer 7.0, 8.0, 9.0, 10.0 (desktop version)   
					Mozilla Firefox 3.6.x, ESR 10.0.x, ESR 17.0.x   
					When using ETERNUS Web GUI to connect the ETERNUS DX Disk storage system, the default port number is 80   
					for http.   
					The LAN port for operation management on the ETERNUS DX Disk storage system uses Ethernet (1000Base-T /   
					100Base-TX / 10Base-T) for the interface. IPv4 and IPv6 are supported as Internet Protocols.   
					55   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
				Chapter 3 Connections   
					3.4 Power Supply Connection   
					The following items are supported in firmware version V10L30 or later:   
					• Internet Explorer 9.0   
					• Firefox ESR 10.0.x   
					• IPv6   
					The following item is supported in firmware version V10L40 or later:   
					• Internet Explorer 10.0 (desktop version)   
					The following item is supported in firmware version V10L45 or later:   
					• Firefox ESR 17.0.x   
					■ LAN for operation management   
					In an ETERNUS DX Disk storage system, the system administrator logs on to the ETERNUS DX Disk storage   
					system via a LAN to set the RAID configuration, manage operations, and perform maintenance. The computer   
					for operation management that is used for accessing the ETERNUS DX Disk storage system via ETERNUS Web   
					GUI or ETERNUS CLI is called an administration terminal.   
					In addition, the functions that are provided by the management/monitoring server on the LAN can be used.   
					These functions include SNMP (device monitoring), SMTP (e-mail sending), NTP (time correction), syslog   
					(event notification and audit log sending), RADIUS (user authentication), and KMIP(key management).   
					■ LAN for remote support   
					Various failures that occur in the ETERNUS DX Disk storage system are notified to the remote support center.   
					Remote support connection can be separated from the LAN for operation management.   
					3.4   
					Power Supply Connection   
					Connect the power cords (AC cables) of the ETERNUS DX Disk storage system to the power sockets, the UPS   
					sockets, or the power control unit sockets.   
					Refer to "2.6 Outlet/Socket Specifications" (page 37) for details about the types and the number of power   
					outlets/sockets.   
					Two power supply units (PSU#0 and PSU#1) are installed in each enclosure. Make sure that power cords are   
					connected to both of the power supply units.   
					56   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				Chapter 3 Connections   
					3.4 Power Supply Connection   
					3.4.1   
					Input Power Supply Lines   
					Multiple power supply facilities in the building or UPS units are recommended for power supply redundancy.   
					When the ETERNUS DX Disk storage system power supply is redundantly configured, business can continue   
					even if one of the power lines fails.   
					Alternatively, optimal system design (including the server) may instead lead to the ETERNUS DX Disk storage   
					system being configured with only a single power supply facility or UPS unit. Which configuration is selected   
					will depend on system availability requirement considerations.   
					Figure 3.13 Dual-line power supply when connecting to power sockets   
					ETERNUS DX   
					Power distribution unit   
					Disk storage system   
					Line 1   
					PSU   
					PSU   
					Line 0   
					Figure 3.14 Dual-line power supply when connecting to UPS units   
					ETERNUS DX   
					Power distribution unit   
					Disk storage system   
					UPS   
					PSU   
					Line 1   
					UPS   
					PSU   
					Line 0   
					Figure 3.15 Single-line power supply when connecting to power sockets   
					ETERNUS DX   
					Disk storage system   
					Power distribution unit   
					PSU   
					Line 0   
					PSU   
					57   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
					 
				Chapter 3 Connections   
					3.4 Power Supply Connection   
					Figure 3.16 Single-line power supply when connecting to a UPS unit   
					ETERNUS DX   
					Disk storage system   
					Power distribution unit   
					UPS   
					PSU   
					Line 0   
					PSU   
					Figure 3.17 Single-line power supply when connecting to a power socket and a UPS unit   
					ETERNUS DX   
					Power distribution unit   
					Disk storage system   
					PSU   
					Line 0   
					UPS   
					PSU   
					When the power distribution units are separately connected to line 0 (PSU#0) and line 1 (PSU#1), the   
					availability of the power supply facilities is improved.   
					ETERNUS DX   
					Disk storage system   
					Power distribution unit   
					Power distribution unit   
					DE #0x   
					...   
					DE #01   
					CE   
					Line 0   
					Line 1   
					58   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
				Chapter 3 Connections   
					3.4 Power Supply Connection   
					3.4.2   
					UPS Connection   
					It is recommended that an Uninterruptible Power Supply System (UPS) be used as the power supply source for   
					the ETERNUS DX Disk storage system to cope with power outages and momentary voltage drops in the normal   
					power supply.   
					Note that when connecting an ETERNUS DX Disk storage system to a UPS with one power supply line, the total   
					value of the power requirements for all the enclosures must not exceed the UPS output capacity.   
					When one of the power supply lines fails for redundantly configured UPS units with two power supply lines, all   
					of the power for the ETERNUS DX Disk storage system must be supplied from the other line. Select a UPS that   
					can supply sufficient power so that the total value of the power requirements does not exceed the UPS output   
					capacity in case only one power supply line is available.   
					For details about the necessary UPS output capacity, refer to the specifications of the UPS that is used.   
					A UPS must satisfy the following conditions:   
					● Rating capacity   
					Secure a sufficient rating capacity for the total value of the maximum power requirements for the   
					enclosures that are to be installed.   
					For the maximum power requirements of each enclosure, refer to "2.1 Installation Specifications" (page   
					27).   
					● Supply time   
					The total time for the server to shut down and for the ETERNUS DX Disk storage system to power off   
					(maximum of six minutes) must be taken into consideration for the power supply time of the battery.   
					● Switching time during power failure   
					The normal power supply must be switched to UPS output within 11ms after a power failure occurs.   
					● Socket type   
					If the power plug type and the socket type of the UPS do not match, it is necessary to equip the UPS (AC   
					output) with an appropriate type of socket. Request a qualified electrician to perform the necessary work to   
					make terminal block connections available.   
					● Power supply configuration   
					If a UPS is used, make sure that it supplies power to all the enclosures.   
					Configurations where the controller enclosure is powered by the UPS while the drive enclosures are   
					powered directly from AC are not supported.   
					59   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				Chapter 3 Connections   
					3.5 Power Synchronized Connections   
					3.5   
					Power Synchronized Connections   
					This section describes connections to automatically control powering the ETERNUS DX Disk storage system on   
					and off with a server.   
					Do   
					WARNING   
					• In order to control powering the ETERNUS DX Disk storage system on and off   
					with servers, the power control of the ETERNUS DX Disk storage system must   
					be linked with all of the connected servers. If some of the servers are not   
					linked, data errors may occur in these servers when the ETERNUS DX Disk   
					storage system is turned off by using power control from the other linked   
					servers.   
					■ Power synchronized unit   
					A power synchronized unit enables the ETERNUS DX Disk storage system to be powered on and off with a   
					server. The power synchronized unit detects changes in the AC power output of a UPS unit that is connected to   
					a server (server UPS unit) and automatically turns on and off the ETERNUS DX Disk storage system. In addition   
					to server UPS units, units that control the AC socket power output can also be connected. When three or more   
					servers are connected, power can be synchronized by adding an AC sensor unit.   
					The power synchronized unit detects the AC power output of the target devices for power synchronization and   
					commands the ETERNUS DX Disk storage system to synchronize the power with the target devices.   
					When the power synchronized unit detects the AC power output of any server UPS unit, the power   
					synchronized unit commands the ETERNUS DX Disk storage system to turn on.   
					When the power synchronized unit does not detect AC power output in any of the server UPS units, the power   
					synchronized unit commands the ETERNUS DX Disk storage system to turn off.   
					The server UPS unit must have a function in the management software that controls the AC power output   
					according to when the server powers on and off. The server UPS unit must have one unused outlet to connect   
					to the power synchronized unit.   
					60   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				Chapter 3 Connections   
					3.5 Power Synchronized Connections   
					• When connecting one or two servers   
					Figure 3.18 Power control using a power synchronized unit (when connecting one or two servers)   
					UPS setting   
					Turns on: 1   
					Turns off: 2   
					Turns on: 2   
					Turns off: 1   
					Server   
					UPS   
					management   
					software   
					UPS   
					Power synchronized unit   
					PWC   
					4 
					ETERNUS DX   
					Disk storage system   
					RS232C cable   
					PWC   
					An instruction is   
					issued to turn on/off   
					the ETERNUS DX   
					Disk storage   
					3 
					system when AC   
					output/no AC output   
					is detected.   
					● Powering on sequence   
					1 
					2 
					Power on of all the server UPS units   
					Server startup   
					The server OS startup is suspended until the ETERNUS DX Disk storage system startup is complete   
					(*1).   
					3 
					4 
					Issuance of command to turn on the ETERNUS DX Disk storage system from the power synchronized   
					unit   
					ETERNUS DX Disk storage system startup   
					*1: The server must be set to suspend server OS startup until the ETERNUS DX Disk storage system startup is   
					complete.   
					61   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				Chapter 3 Connections   
					3.5 Power Synchronized Connections   
					● Powering off sequence   
					1 
					2 
					3 
					Shutdown of all the servers   
					Shutdown of all the server UPS units   
					Issuance of command to turn off the ETERNUS DX Disk storage system from the power synchronized   
					unit   
					4 
					ETERNUS DX Disk storage system shutdown   
					• When connecting three or more servers   
					Figure 3.19 Power control using a power synchronized unit (when connecting three or more servers)   
					Turns on: 1   
					Turns off: 2   
					Turns on: 2   
					Turns off: 1   
					Server#1   
					UPS unit for   
					Server#1   
					Server#3   
					UPS unit for   
					Server#3   
					AC sensor   
					unit#1   
					Server#0   
					UPS unit for   
					Server#0   
					Server#2   
					UPS unit for   
					Server#2   
					AC sensor   
					unit#0   
					Power synchronized   
					unit#0   
					PWC PWC   
					ETERNUS DX   
					4 
					Disk storage system   
					PWC   
					3 
					ETERNUS DX   
					4 
					Disk storage system   
					PWC   
					62   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				Chapter 3 Connections   
					3.5 Power Synchronized Connections   
					● Powering on sequence   
					1 
					2 
					Power on of all the server UPS units   
					Server startup   
					The server OS startup is suspended until the ETERNUS DX Disk storage system startup is complete   
					(*1).   
					3 
					4 
					Issuance of command to turn on the ETERNUS DX Disk storage system from the power synchronized   
					unit   
					ETERNUS DX Disk storage system startup   
					*1: The server must be set to suspend server OS startup until the ETERNUS DX Disk storage system startup is   
					complete.   
					● Powering off sequence   
					1 
					2 
					3 
					Shutdown of all the servers   
					Shutdown of all the server UPS units   
					Issuance of command to turn off the ETERNUS DX Disk storage system from the power synchronized   
					unit   
					4 
					ETERNUS DX Disk storage system shutdown   
					Refer to the manual that is provided with a power synchronized unit for details about connection   
					configurations with power synchronized units and required settings.   
					63   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
				Chapter 4   
					Rack and Optional Product Installation   
					This chapter explains the requirements for installation of racks and the optional products for an ETERNUS DX   
					Disk storage system.   
					4.1   
					Rack Installation Requirements   
					This section explains the requirements for installing the ETERNUS DX Disk storage system in a 19-inch rack.   
					4.1.1   
					Placement in the Rack   
					Note the following when installing the ETERNUS DX Disk storage system in the rack.   
					• The center of gravity must be taken into consideration to prevent a rack from toppling over. Enclosures   
					should generally be installed from bottom to top to lower the center of gravity and to ensure the safe use   
					of racks.   
					• Enclosures are installed in the following order (from bottom to top).   
					Table 4.1 Enclosure installation order   
					Order   
					Enclosure   
					Power distribution unit (PDU)   
					Controller enclosure (CE)   
					Drive enclosure (DE)   
					Size (height)   
					1 
					2 
					3 
					1U/2U   
					2U   
					2U   
					Install drive enclosures in order of DE-IDs (drive enclosure numbers)   
					. 
					• When determining the rack-mounting layout, consider the placement of each enclosure and the power   
					distribution unit in the rack and the length of each cable. For example, if the ETERNUS DX Disk storage   
					system is installed at the top of a 1800mm rack, the surplus length of the power cord at the bottom of a   
					rack should be about 2m.   
					• If the storage system is installed at the bottom of a rack, a space for the surplus of cables may not be   
					available in some racks, preventing the storage system from being pulled out when maintenance work is   
					required.   
					In this case, secure a space of 1U or more at the bottom when installing the storage system.   
					• If drive enclosures are to be added in the future, securing sufficient space for power distribution units in   
					the bottom of the rack is recommended.   
					64   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
					 
					 
				Chapter 4 Rack and Optional Product Installation   
					4.1 Rack Installation Requirements   
					4.1.2   
					Cable Connection   
					■ Power supply connection   
					It is recommended that the power cords (AC cables) of the enclosures are connected to the power distribution   
					units that are installed in the same rack. Secure the necessary number of power outlets within the same rack   
					to avoid connecting power cords to power outlets in different racks.   
					It may be necessary to purchase additional power distribution units depending on the installation locations of   
					enclosures.   
					The length of the AC output cable that is supplied with the power distribution unit is 3m.   
					Figure 4.1 AC cable connection   
					Rack-1   
					Rack-2   
					DE   
					DE   
					DE   
					DE   
					DE   
					DE   
					DE   
					DE   
					CE   
					PDU   
					PDU   
					An AC cable should not be   
					connected to a power   
					: AC cable   
					distribution unit that is installed   
					in a different rack.   
					65   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
				Chapter 4 Rack and Optional Product Installation   
					4.1 Rack Installation Requirements   
					■ Connections between enclosures   
					If enclosures are installed in multiple racks or are installed with space in the same rack, the QSFP cables   
					(0.75m) that are included with the ETERNUS DX Disk storage system may be too short for connections   
					between enclosures.   
					In this case, use the Extension cable between enclosures. The length of the Extension cable between   
					enclosures that is provided is 3m or 6m. Enclosures in different racks can be installed within this length.   
					Figure 4.2 QSFP cable connection (single-controller type)   
					Rack-1   
					Rack-2   
					DE   
					DE   
					DE   
					DE   
					DE   
					DE   
					DE   
					DE   
					CE   
					PDU   
					PDU   
					: Cable supplied as standard   
					: Extension cable between enclosures   
					66   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				Chapter 4 Rack and Optional Product Installation   
					4.2 Installable Racks   
					Figure 4.3 QSFP cable connection (dual-controller type)   
					Rack-1   
					Rack-2   
					DE   
					DE   
					DE   
					DE   
					DE   
					DE   
					CE   
					ACS   
					DE   
					DE   
					ACS   
					: Cable supplied as standard   
					: Extension cable between enclosures   
					4.2   
					Installable Racks   
					This section explains the racks in which the ETERNUS DX Disk storage system can be installed.   
					4.2.1   
					Fujitsu Racks   
					The ETERNUS DX Disk storage system can be installed in a Fujitsu 19-inch rack. For information about whether   
					the ETERNUS DX Disk storage system can be installed in an EOLed rack or not, contact your sales   
					representative.   
					67   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
				Chapter 4 Rack and Optional Product Installation   
					4.2 Installable Racks   
					4.2.2   
					Non-Fujitsu Racks   
					ETERNUS DX Disk storage systems are developed and their operation is guaranteed on the assumption that   
					they are installed in Fujitsu 19-inch racks. Since the ETERNUS DX Disk storage system cannot be tested (for   
					cooling and strength) in non-Fujitsu 19-inch racks, the operations of ETERNUS DX Disk storage systems cannot   
					be guaranteed. Any problem that may occur by installing the ETERNUS DX Disk storage system in non-Fujitsu   
					racks is not covered by the warranty.   
					If the ETERNUS DX Disk storage system needs to be installed in a non-Fujitsu rack, the following conditions   
					must be satisfied.   
					■ Rack specifications   
					Use the rack mount kit supplied with the product to install the ETERNUS DX Disk storage system in the rack.   
					The rack specifications must satisfy the conditions listed below. For rack specifications, refer to the manual   
					that is supplied with the rack that is used.   
					• Pitch for mounting holes   
					EIA Standard Universal pitch   
					• Size for mounting holes   
					The size must be 9mm or more.   
					• Load bearing capacity   
					The load bearing capacity must be equal to or larger than the total weight of the ETERNUS DX Disk storage   
					system.   
					• Unit installation area   
					
					Figure 4.4 Unit installation area   
					(1)   
					(2)   
					(3)   
					Rack rails   
					ETERNUS DX   
					Disk storage system   
					(4)   
					Rack front door   
					Rack pillars   
					Rack rear door   
					68   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
				Chapter 4 Rack and Optional Product Installation   
					4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)   
					Table 4.2 Specifications for the unit installation area   
					Specification   
					Condition   
					40mm or more   
					(1)   
					Rack front space   
					(Space between the fixed part of the ETERNUS DX Disk storage system on   
					the front side and the front of the rack)   
					(2)   
					(3)   
					Mount bracket length   
					(Size between each end of the front and rear rack pillars)   
					685mm to 775mm   
					830mm or more   
					Rack space   
					(Space between the fixed part of the ETERNUS DX Disk storage system on   
					the front side and the rear of the rack)   
					(4)   
					Rack mount kit installation area   
					482mm or more   
					(recommended)   
					■ Placement conditions   
					When determining service areas, refer to the installation document of the rack to be used.   
					Install air conditioning in order to ensure that the interior temperature of the rack satisfies the temperature   
					conditions listed in "2.1 Installation Specifications" (page 27) and "2.5.1 Air Conditioning" (page 36).   
					4.3   
					Standard Installation Rules Before Shipment   
					(Only for Regions Other than EMEA&I)   
					This section explains the rules for combining the following optional products and standard installation rules   
					that apply before shipment from the factory.   
					• Host interfaces   
					• Drive enclosures   
					• Drives   
					69   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
				Chapter 4 Rack and Optional Product Installation   
					4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)   
					4.3.1   
					Host Interfaces   
					This section explains the installation rules for host interfaces.   
					The following types of host interfaces (CA) are available:   
					• FC 16Gbit/s (dual port type)   
					• FC 8Gbit/s (dual port type)   
					• iSCSI 10Gbit/s (dual port type)   
					• iSCSI 10Gbit/s (dual port type, without SFP+ modules)   
					• iSCSI 1Gbit/s (dual port type)   
					• FCoE 10Gbit/s (dual port type)   
					• FCoE 10Gbit/s (dual port type, without SFP+ modules)   
					• SAS 6Gbit/s (dual port type)   
					Different types of interfaces can be mixed for the same ETERNUS DX Disk storage system.   
					
					For a dual-controller type, the configuration is the same for Controller 0 (CM#0) and Controller 1 (CM#1).   
					The following table shows the priority order of host interface installation.   
					Table 4.3 Priority order of host interface installation   
					Priority order   
					Type   
					Interface   
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					FC 16Gbit/s   
					FC 8Gbit/s   
					iSCSI 10Gbit/s   
					iSCSI 10Gbit/s (without SFP+ modules)   
					iSCSI 1Gbit/s   
					Host interface (2port)   
					FCoE 10Gbit/s   
					FCoE 10Gbit/s (without SFP+ modules)   
					SAS 6Gbit/s   
					■ For a single-controller type   
					Figure 4.5 Installation diagram for a host interface (single-controller type)   
					Port   
					#0   
					Port   
					#1   
					Port   
					#0   
					Port   
					#1   
					CA#0   
					CA#1   
					Expansion   
					Controller 0 (CM#0)   
					70   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
					 
				Chapter 4 Rack and Optional Product Installation   
					4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)   
					■ For a dual-controller type   
					Figure 4.6 Installation diagram for host interfaces (dual-controller type)   
					Port   
					#0   
					Port   
					#1   
					Port   
					#0   
					Port   
					#1   
					Port   
					#0   
					Port   
					#1   
					Port   
					#0   
					Port   
					#1   
					CA#0   
					CA#1   
					CA#0   
					CA#1   
					Expansion   
					Expansion   
					Controller 0 (CM#0)   
					Controller 1 (CM#1)   
					4.3.2   
					Drive Enclosures   
					This section explains the installation rules for drive enclosures. 2.5" type and 3.5" type drive enclosures can be   
					installed together in the ETERNUS DX Disk storage system.   
					The priority order of drive enclosure installation varies depending on the controller enclosure type.   
					■ 2.5" type controller enclosure   
					Table 4.4 Priority order of drive enclosure installation (for 2.5" type controller enclosure)   
					Priority order   
					Type   
					1 
					2 
					Drive enclosure (2.5inch)   
					Drive enclosure (3.5inch)   
					■ 3.5" type controller enclosure   
					Table 4.5 Priority order of drive enclosure installation (for 3.5" type controller enclosure)   
					Priority order   
					Type   
					1 
					2 
					Drive enclosure (3.5inch)   
					Drive enclosure (2.5inch)   
					For the ETERNUS DX80 S2/DX90 S2, up to nine drive enclosures can be installed.   
					When only 2.5" type enclosures are used for the ETERNUS DX80 S2, up to four drive enclosures can be   
					installed.   
					DE-IDs are automatically assigned for a drive enclosure based on the installation order.   
					71   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
					 
					 
				Chapter 4 Rack and Optional Product Installation   
					4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)   
					4.3.3   
					Drives   
					This section explains the installation rules for drives.   
					■ 2.5" drives   
					The following table shows the priority order of 2.5" drive installation.   
					Table 4.6 Priority order of 2.5" drive installation   
					Priority order   
					Type   
					Drive capacity/quantity   
					100GB (SLC) x 2   
					RAID level   
					1 
					2 
					RAID1   
					100GB (SLC) x 6   
					100GB (SLC) x 4   
					100GB (SLC) x 1   
					200GB (SLC) x 2   
					200GB (SLC) x 6   
					200GB (SLC) x 4   
					200GB (SLC) x 1   
					400GB (SLC) x 2   
					400GB (SLC) x 6   
					400GB (SLC) x 4   
					400GB (SLC) x 1   
					400GB (MLC) x 6   
					400GB (MLC) x 4   
					400GB (MLC) x 1   
					800GB (MLC) x 2   
					800GB (MLC) x 6   
					800GB (MLC) x 4   
					800GB (MLC) x 1   
					RAID1+0   
					RAID5   
					3 
					4 
					Hot spare   
					RAID1   
					5 
					6 
					RAID1+0   
					RAID5   
					7 
					8 
					Hot spare   
					RAID1   
					9 
					10   
					11   
					12   
					13   
					14   
					15   
					16   
					17   
					18   
					19   
					SSD (2.5inch)   
					RAID1+0   
					RAID5   
					Hot spare   
					RAID1+0   
					RAID5   
					Hot spare   
					RAID1   
					RAID1+0   
					RAID5   
					Hot spare   
					72   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
				Chapter 4 Rack and Optional Product Installation   
					4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)   
					Priority order   
					Type   
					Drive capacity/quantity   
					300GB/15krpm x 2   
					300GB/15krpm x 6   
					300GB/15krpm x 6   
					300GB/15krpm x 6   
					300GB/15krpm x 1   
					300GB/10krpm x 2   
					300GB/10krpm x 6   
					300GB/10krpm x 6   
					300GB/10krpm x 6   
					300GB/10krpm x 1   
					450GB/10krpm x 2   
					450GB/10krpm x 6   
					450GB/10krpm x 6   
					450GB/10krpm x 6   
					450GB/10krpm x 1   
					600GB/10krpm x 2   
					600GB/10krpm x 6   
					600GB/10krpm x 6   
					600GB/10krpm x 6   
					600GB/10krpm x 1   
					900GB/10krpm x 2   
					900GB/10krpm x 6   
					900GB/10krpm x 6   
					900GB/10krpm x 6   
					900GB/10krpm x 1   
					RAID level   
					20   
					21   
					22   
					23   
					24   
					25   
					26   
					27   
					28   
					29   
					30   
					31   
					32   
					33   
					34   
					35   
					36   
					37   
					38   
					39   
					40   
					41   
					42   
					43   
					44   
					RAID1   
					RAID1+0   
					RAID5   
					RAID6   
					Hot spare   
					RAID1   
					RAID1+0   
					RAID5   
					Disk Drive (2.5inch)   
					RAID6   
					Hot spare   
					RAID1   
					RAID1+0   
					RAID5   
					RAID6   
					Hot spare   
					RAID1   
					RAID1+0   
					RAID5   
					RAID6   
					Hot spare   
					RAID1   
					Disk Drive (2.5inch)   
					RAID1+0   
					RAID5   
					RAID6   
					Hot spare   
					73   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
				Chapter 4 Rack and Optional Product Installation   
					4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)   
					Priority order   
					Type   
					Drive capacity/quantity   
					300GB/10krpm x 2   
					300GB/10krpm x 6   
					300GB/10krpm x 6   
					300GB/10krpm x 6   
					300GB/10krpm x 1   
					450GB/10krpm x 2   
					450GB/10krpm x 6   
					450GB/10krpm x 6   
					450GB/10krpm x 6   
					450GB/10krpm x 1   
					600GB/10krpm x 2   
					600GB/10krpm x 6   
					600GB/10krpm x 6   
					600GB/10krpm x 6   
					600GB/10krpm x 1   
					900GB/10krpm x 2   
					900GB/10krpm x 6   
					900GB/10krpm x 6   
					900GB/10krpm x 6   
					900GB/10krpm x 1   
					1TB/7.2krpm x 2   
					RAID level   
					45   
					46   
					47   
					48   
					49   
					50   
					51   
					52   
					53   
					54   
					55   
					56   
					57   
					58   
					59   
					60   
					61   
					62   
					63   
					64   
					65   
					66   
					67   
					68   
					69   
					RAID1   
					RAID1+0   
					RAID5   
					RAID6   
					Hot spare   
					RAID1   
					RAID1+0   
					RAID5   
					RAID6   
					Hot spare   
					RAID1   
					Self Encrypting Disk Drive   
					(2.5inch)   
					RAID1+0   
					RAID5   
					RAID6   
					Hot spare   
					RAID1   
					RAID1+0   
					RAID5   
					RAID6   
					Hot spare   
					RAID1   
					1TB/7.2krpm x 6   
					RAID1+0   
					RAID5   
					Disk Drive (2.5inch)   
					1TB/7.2krpm x 6   
					1TB/7.2krpm x 6   
					RAID6   
					1TB/7.2krpm x 1   
					Hot spare   
					Up to twenty-four 2.5" drives can be installed in a controller enclosure or a drive enclosure (2.5" type). Drives   
					with different types can be installed in a single enclosure.   
					Install drives in the slots of a controller enclosure from Slot#0 to Slot#23 in ascending order according to the   
					installation order in Table 4.6. Then, install drives in the slots of a drive enclosure from Slot#0 to Slot#23 in   
					ascending order.   
					Figure 4.7 Installation diagram for 2.5" drives   
					74   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				Chapter 4 Rack and Optional Product Installation   
					4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)   
					■ 3.5" drives   
					The following table shows the priority order of 3.5" drive installation.   
					Table 4.7 Priority order of 3.5" drive installation   
					Priority order   
					Type   
					Drive capacity/quantity   
					100GB (SLC) x 2   
					RAID level   
					1 
					RAID1   
					2 
					100GB (SLC) x 6   
					100GB (SLC)x 4   
					RAID1+0   
					RAID5   
					3 
					4 
					100GB (SLC) x 1   
					200GB (SLC) x 2   
					200GB (SLC) x 6   
					200GB (SLC) x 4   
					200GB (SLC) x 1   
					400GB (SLC) x 2   
					400GB (SLC) x 6   
					400GB (SLC) x 4   
					400GB (SLC) x 1   
					400GB (MLC) x 6   
					400GB (MLC) x 4   
					400GB (MLC) x 1   
					800GB (MLC) x 2   
					800GB (MLC) x 6   
					800GB (MLC) x 4   
					800GB (MLC) x 1   
					300GB/15krpm x 2   
					300GB/15krpm x 6   
					300GB/15krpm x 6   
					300GB/15krpm x 6   
					300GB/15krpm x 1   
					450GB/15krpm x 2   
					450GB/15krpm x 6   
					450GB/15krpm x 6   
					450GB/15krpm x 6   
					450GB/15krpm x 1   
					Hot spare   
					RAID1   
					5 
					6 
					RAID1+0   
					RAID5   
					7 
					8 
					Hot spare   
					RAID1   
					9 
					10   
					11   
					12   
					13   
					14   
					15   
					16   
					17   
					18   
					19   
					20   
					21   
					22   
					23   
					24   
					25   
					26   
					27   
					28   
					29   
					SSD (3.5inch)   
					RAID1+0   
					RAID5   
					Hot spare   
					RAID1+0   
					RAID5   
					Hot spare   
					RAID1   
					RAID1+0   
					RAID5   
					Hot spare   
					RAID1   
					RAID1+0   
					RAID5   
					RAID6   
					Hot spare   
					RAID1   
					Disk Drive (3.5inch)   
					RAID1+0   
					RAID5   
					RAID6   
					Hot spare   
					75   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				Chapter 4 Rack and Optional Product Installation   
					4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)   
					Priority order   
					Type   
					Drive capacity/quantity   
					600GB/15krpm x 2   
					600GB/15krpm x 6   
					600GB/15krpm x 6   
					600GB/15krpm x 6   
					600GB/15krpm x 1   
					1TB/7.2krpm x 2   
					1TB/7.2krpm x 6   
					1TB/7.2krpm x 6   
					1TB/7.2krpm x 6   
					1TB/7.2krpm x 1   
					2TB/7.2krpm x 2   
					2TB/7.2krpm x 6   
					2TB/7.2krpm x 6   
					2TB/7.2krpm x 6   
					2TB/7.2krpm x 1   
					3TB/7.2krpm x 2   
					3TB/7.2krpm x 6   
					3TB/7.2krpm x 6   
					3TB/7.2krpm x 6   
					3TB/7.2krpm x 1   
					4TB/7.2krpm x 2   
					4TB/7.2krpm x 6   
					4TB/7.2krpm x 6   
					4TB/7.2krpm x 6   
					4TB/7.2krpm x 1   
					RAID level   
					30   
					31   
					32   
					33   
					34   
					35   
					36   
					37   
					38   
					39   
					40   
					41   
					42   
					43   
					44   
					45   
					46   
					47   
					48   
					49   
					50   
					51   
					52   
					53   
					54   
					RAID1   
					RAID1+0   
					RAID5   
					RAID6   
					Hot spare   
					RAID1   
					RAID1+0   
					RAID5   
					RAID6   
					Hot spare   
					RAID1   
					RAID1+0   
					RAID5   
					Disk Drive (3.5inch)   
					RAID6   
					Hot spare   
					RAID1   
					RAID1+0   
					RAID5   
					RAID6   
					Hot spare   
					RAID1   
					RAID1+0   
					RAID5   
					RAID6   
					Hot spare   
					Up to twelve 3.5" drives can be installed in a controller enclosure or a drive enclosure (3.5" type).   
					Drives with different types can be installed in a single enclosure.   
					Install drives in the slots of a controller enclosure from Slot#0 to Slot#11 in ascending order according to the   
					installation order in Table 4.7. Then, install drives in the slots of a drive enclosure from Slot#0 to Slot#11 in   
					ascending order.   
					Figure 4.8 Installation diagram for 3.5" drives   
					Slot#11   
					Slot#8   
					Slot#4   
					Slot#0   
					Slot#9   
					Slot#5   
					Slot#1   
					Slot#10   
					Slot#6   
					Slot#2   
					Slot#7   
					Slot#3   
					76   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				Chapter 4 Rack and Optional Product Installation   
					4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)   
					4.3.4   
					Drive Installation Examples   
					This section provides examples of drive installation at shipment.   
					■ 2.5" type controller enclosure   
					For a 2.5" type controller enclosure, 2.5" type drive enclosures are installed before 3.5" type drive enclosures.   
					2.5" drives are installed in the 2.5" type controller enclosure and drive enclosures, and 3.5" drives are installed   
					in the 3.5" type drive enclosures.   
					Figure 4.9 Drive installation example at shipment (2.5" type controller enclosure)   
					DE#2   
					F 
					F 
					F 
					F 
					H3   
					F 
					F 
					DE#1   
					H 
					1 
					H 
					1 
					H 
					2 
					C 
					C 
					D 
					D 
					D 
					D 
					D 
					D 
					E 
					E 
					E 
					E 
					E 
					E 
					CE#0   
					A 
					A 
					A 
					A 
					A 
					A 
					A 
					A 
					A 
					A 
					A 
					A 
					B 
					B 
					B 
					B 
					B 
					B 
					B 
					B 
					B 
					B 
					B 
					B 
					Installation order   
					A: 2.5" SSD (100GB, RAID5) x 3   
					B: 2.5" SSD (200GB, RAID1+0) x 2   
					H1: 2.5" SSD (200GB, hot spare) x 2   
					C: 2.5" SAS (450GB, RAID1)   
					D: 2.5" SAS (450GB, RAID6)   
					E: 2.5" SAS (600GB, RAID5)   
					H2: 2.5" SAS (600GB, hot spare)   
					F: 3.5" Nearline SAS (2TB, RAID5)   
					H3: 3.5" Nearline SAS (2TB, hot spare)   
					77   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
					 
				Chapter 4 Rack and Optional Product Installation   
					4.3 Standard Installation Rules Before Shipment (Only for Regions Other than EMEA&I)   
					■ 3.5" type controller enclosure   
					For a 3.5" type controller enclosure, 3.5" type drive enclosures are installed before 2.5" type drive enclosures.   
					3.5" drives are installed in the 3.5" type controller enclosure and drive enclosures, and 2.5" drives are installed   
					in the 2.5" type drive enclosures.   
					Figure 4.10 Drive installation example at shipment (3.5" type controller enclosure)   
					DE#2   
					H 
					2 
					H 
					3 
					C 
					C 
					C 
					C 
					D 
					D 
					DE#1   
					B 
					B 
					B 
					H1   
					B 
					B 
					B 
					CE#0   
					A 
					A 
					A 
					A 
					A 
					A 
					A 
					A 
					A 
					A 
					A 
					A 
					Installation order   
					A: 3.5" Nearline SAS (1TB, RAID1+0) x 2   
					B: 3.5" Nearline SAS (2TB, RAID5)   
					H1: 3.5" Nearline SAS (2TB, hot spare)   
					C: 2.5" SSD (200GB, RAID5)   
					H2: 2.5" SSD (200GB, hot spare)   
					D: 2.5" SAS (300GB, RAID1)   
					H3: 2.5" SAS (300GB, hot spare)   
					78   
					ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Site Planning-   
					Copyright 2013 FUJITSU LIMITED   
					P3AM-4822-12ENZ0   
					 
				ETERNUS DX80 S2/DX90 S2 Disk storage system   
					User's Guide -Site Planning-   
					P3AM-4822-12ENZ0   
					Date of issuance: June 2013   
					Issuance responsibility: FUJITSU LIMITED   
					• 
					• 
					The content of this manual is subject to change without notice.   
					This manual was prepared with the utmost attention to detail.   
					However, Fujitsu shall assume no responsibility for any operational problems as the result of   
					errors, omissions, or the use of information in this manual.   
					• 
					• 
					Fujitsu assumes no liability for damages to third party copyrights or other rights arising from   
					the use of any information in this manual.   
					The content of this manual may not be reproduced or distributed in part or in its entirety   
					without prior permission from Fujitsu.   
				 |