| User’s Guide   Models:   f f f CBS-2051e   CBS-2052e   CBS-2052e20   NOTICE TO INSTALLER: Please leave this book with the machine.   Table of Contents   Contact Information ..................................................2   Programming..........................................................10   Batch Settings.....................................................10   Temperature Settings .........................................11   Advanced Settings and Diagnostics ...................11   Relay Test...........................................................12   Error Codes ............................................................13   Parts .......................................................................14   Description & Features.............................................2   Specifications............................................................2   Requirements........................................................2   Weights and Capacities ........................................2   Electrical Configuration and Brewing Efficiency ...3   Dimensions & Utility Connections.............................4   Installation.................................................................6   Operating Instructions ..............................................9   FETCO®, LUXUS®, EXTRACTOR® and Driven To Pioneer Innovation™ are trademarks or trade names of Food Equipment Technologies Company.   © 2005 Food Equipment Technologies Company Part # P021 October 20, 2005   Electrical Configuration and Brewing Efficiency   US & Canada   CBS-2051e   1.5 gallons per batch   Batches per Hour* (max 11)   Electrical   Heater   Configuration   Voltage   (AC)   Maximum   Amp draw   Config. Code   Phase   Wires   KW   4.6   5.1   6.1   Cold Water   Hot Water   E51016   2 X 3 KW   120/208   120/220   120/240   22.1   23.4   25.5   7.7   11.0   single   3 + ground   8.6   11.0   10.3   11.0   CBS-2052e   1.5 gallons per batch   Batches per Hour* (max 22)   Electrical   Heater   Configuration   Voltage   (AC)   Maximum   Amp draw   Config. Code   Phase   Wires   KW   4.6   5.1   6.1   Cold Water   Hot Water   E52016   Universal   Wiring   Option 1   2 X 3 KW   (Factory Setting)   120/208   120/220   120/240   22.4   23.7   25.8   7.7   18.6   single   3 + ground   8.6   20.8   10.3   22.0   Option 2   3 X 3 KW   120/208   120/220   120/240   6.9   7.7   9.1   19.5   20.6   22.5   11.5   12.9   15.4   22.0   22.0   22.0   Total 3 X 3 KW   Heaters   three   4 + ground   3 + ground   E52026   Universal   Wiring   Option 1   2 X 5 KW   120/208   120/220   120/240   7.6   8.5   10.1   36.9   39.0   42.5   12.8   14.4   17.1   22.0   22.0   22.0   single   three   Option 2   3 X 5 KW   (Factory Setting)   120/208   120/220   120/240   11.4   32.0   33.9   36.9   19.2   22.0   22.0   22.0   22.0   22.0   Total 3 X 5 KW   Heaters   4 + ground 12.7   15.1   CBS-2052e20   2.0 gallons per batch   Batches per Hour* (max 18)   Electrical   Heater   Configuration   Voltage   (AC)   Maximum   Amp draw   Config. Code   Phase   Wires   KW   4.6   5.1   6.1   Cold Water   Hot Water   E53016   Universal   Wiring   Option 1   2 X 3 KW   (Factory Setting)   120/208   120/220   120/240   22.4   23.7   25.8   5.8   14.0   single   3 + ground   6.5   15.6   7.7   18.0   Option 2   3 X 3 KW   120/208   120/220   120/240   6.9   7.7   9.1   19.5   20.6   22.5   8.6   10.1   11.6   18.0   18.0   18.0   Total 3 X 3 KW   Heaters   three   4 + ground   3 + ground   E53026   Universal   Wiring   Option 1   2 X 5 KW   120/208   120/220   120/240   7.6   8.5   10.1   36.9   39.0   42.5   9.6   11.2   12.8   18.0   18.0   18.0   single   three   Option 2   3 X 5 KW   (Factory Setting)   120/208   120/220   120/240   11.4   32.0   33.9   36.9   14.4   16.5   16.5   18.0   18.0   18.0   Total 3 X 5 KW   Heaters   4 + ground 12.7   15.1   * Based on standard factory settings: 4.0 minute brew time; 0% prewet, 0% bypass; 200 F water.   Export   CBS-2051e   1.5 gallons per batch   Batches per Hour* (max 11)   Electrical   Heater   Configuration   Voltage   (AC)   Maximum   Amp draw   Config. Code   Phase   Wires   KW   Cold Water   Hot Water   E51026   2 X 3 KW   220   single   2 + ground   5.1   23.4   8.9   11.0   CBS-2052e   1.5 gallons per batch   Batches per Hour* (max 22)   Electrical   Heater   Configuration   Voltage   (AC)   Maximum   Amp draw   Config. Code   Phase   Wires   KW   Cold Water   Hot Water   E52036   2 X 3 KW   220   single   2 + ground   5.1   23.7   8.6   20.8   CBS-2052e20   2.0 gallons per batch   Batches per Hour* (max 18)   Electrical   Heater   Configuration   Voltage   (AC)   Maximum   Amp draw   Config. Code   Phase   Wires   KW   Cold Water   Hot Water   E53036   2 X 3 KW   220   single   2 + ground   5.1   23.7   6.5   15.6   * Based on standard factory settings: 4.0 minute brew time; 0% prewet, 0% bypass; 200 F water.   3 Dimensions & Utility Connections   CBS-2051e   DWG 201100-000   CBS-2052e   DWG 201101-000   4 CBS-2052e20   DWG 201129-000   5 Installation   (For Qualified Service Technicians Only)   Keys To A Successful Installation   If not installed correctly by qualified personnel, the brewer may not operate properly and damage may result.   Damages resulting from improper installation are not covered by the warranty.   Here are the key points to consider before installation:   Electrical:    All FETCO brewers require NEUTRAL. Ground is not an acceptable substitute. Installation without neutral   may cause damage to the electronic components.    Universal wiring: This brewer can be configured for single or three phase operation. Conversion   instructions are described later in this section.    The electrical diagram and universal wiring instructions are located on the inside of the lower cover.    The installation must comply with applicable federal, state, and local codes having jurisdiction at your   location. Check with your local inspectors to determine what codes will apply.   Plumbing:    This equipment is to be installed to comply with the applicable federal, state, or local plumbing codes.    The water line must be flushed thoroughly prior to connecting it to the brewer to prevent debris from   contaminating the machine.    Verify that the water line will provide at least 1 gallon per minute for the CBS-2051e, and 1.5 gallons per   minute for the CBS-2052e and 2052e20 before connecting it to the brewer.   General:    Utilize only qualified beverage equipment service technicians for installation. A Service Company Directory   Installation Instructions   Brewer Setup   1. Review the Dimensions for the unit you are installing. Verify that the brewer will fit in the space intended for it,   and that the counter or table will support the total weight of the brewer and dispensers when filled.   2. The brewer’s legs are shipped inside the brew baskets.   Warning: Legs are to be adjusted for   leveling the brewer only. Do not use   for height adjustment or extend them   higher than necessary.   Remove the brew basket(s) and the coffee dispenser(s).   Place the brewer on its back and screw in the legs.   3. Place the brewer on the counter or stand.   4. When the brewer is in position, level it front to back as well   as side to side by adjusting the legs.   5. Remove the lower cover to access the water and electrical connections. Knock-outs are provided in the back   and base of the brewer body for the connections.   Water Connection   1. Water inlet is a 3/8 inch male flare fitting.   2. The brewer can be connected to a cold or hot water line. Cold water is preferred for best coffee flavor, but hot   water will allow for faster recovery times.   3. Install a water shut off valve near the brewer to facilitate service. If an in-line water filter is used, it should be   installed after the water shut off valve and in a position to facilitate filter replacement.   4. Flush the water supply line and filter before connecting it to the brewer.   5. Verify that the water line will provide at least 1 gallon per minute for the CBS-2051e, and 1.5 gallons per minute   for the CBS-2052e and 2052e20, and that the water pressure is between 20 and 75 psig.   6. Use a wrench on the factory fitting when connecting the incoming water line. This will reduce stress on the   internal connections and reduce the possibility of leaks developing after the install has been completed.   6 Electrical Connection   1. Verify that the actual voltage at the electrical service connection is compatible with the specifications on the   brewer’s serial number label. Make sure the electrical service includes neutral.   2. The temperature and water tank fill level are pre-set at the factory. There is no need to turn off the heaters   during the installation process. The heaters are disabled by the control board until the tank is full of water. The   heating process will start automatically when the tank has filled.   3. A terminal block is provided for connecting the incoming power wires. Consult local codes to determine if a   cord and plug can be installed, or if the unit must be hard wired.   4. A fused disconnect switch or circuit breaker on the incoming power line must be conveniently located near the   brewer, and its location and markings known to the operators.   Warning: To prevent   electrical shock, this   unit must be properly   grounded.   5. The body of the brewer must be grounded to a suitable building ground.   A ground lug is provided in the brewer next to the power terminal block.   Use only 10 gauge copper wire for grounding.   6. Electrical connections must be secured in-place within the unit to meet   national and local standards.   7. Connect the incoming power wires to the terminal block in accordance with applicable codes.   CBS-2051e   GROUND LUG   L1   N L2   120V   120V   N GROUND   WIRE   208-240V   The CBS-2052e and CBS-2052e20 are shipped from the factory configured for either single phase or three   phase operation, depending on the version that was ordered. A tag attached to the terminal block will indicate   which way the unit was configured.   Notice: The following conversion should be performed only by a qualified beverage equipment   service technician or electrician.   For brewers manufactured before August, 2005:   To change the configuration, arrange the heater wires as shown below. Make sure that all connections are   tight. These instructions are also located on the inside of the lower cover.   HEATER WIRES   HEATER WIRES   CBS-2052e   CBS-2052e   THREE PHASE   CONFIGURATION   SINGLE PHASE   CONFIGURATION   1 & 2 3 & 4 5 & 6   4 & 5   1 & 2   3 & 6   120/208-240 VAC   3 wires + ground   120/208-240 VAC   4 wires + ground   N L1 L2 L3   N L1 L2 L3   GROUND   LUG   GROUND   LUG   NOT   USED   208-240V   208-240V   208-240V   120V   120V   GROUND   WIRE   GROUND   WIRE   208-240V   N N Incoming Power: Connect wires to L1, L2, N, Ground   Incoming Power: Connect wires to L1, L2, L3, N, Grnd   Heater Wires:   Connect wires 1 & 2 to L1   Connect wires 4 & 5 to L2   Connect wires 3 & 6 to L3   Heater Wires:   Connect wires 1 & 2 to L1   Connect wires 3 & 4 to L2   Connect wires 5 & 6 to L3   For brewers manufactured after August 1, 2005:   A jumper wire with instruction tag is provided (pictured at right).   Single Phase: Connect the jumper to L2 and L3.   Connect incoming wires to L1, L2, N, ground.   Three Phase: Do not use the jumper.   Connect wires to L1, L2, L3, N, ground.   When not used, the jumper should remain secured inside the   brewer for future use.   7 Final Setup   1. Turn on the incoming water supply line and inspect both inside and   outside of the brewer for leaks in all fittings and tubes   2. Turn on the incoming power.   3. Press the brewer’s main power switch, which is hidden behind the   front leg of the brewer. The control panel on/off switch will begin   flashing. Press this switch.   4. Within 6 seconds, the hot water tank will begin filling until the water is   sensed by the probe at the top of the tank. The display will read   “FIL”. The heaters will be disabled by the control board until the tank   is full.   5. While the water is heating, the display will read “LO” and the actual   water temperature will be displayed. After the water has reached the   set temperature, the display will be blank. There is no “ready” light.   6. Review the Operating Instructions. Brew one full batch (water only)   on each side to confirm proper fill levels. The brewer is factory set   with water only (no coffee) to dispense the correct amount of water.   If the actual volume is slightly different from the programmed volume,   fine tuning the brewer may be necessary. See #60 – 63 in the   Advanced Settings & Diagnostics section.   7. Re-attach the covers after one final inspection for leaks. Look   closely in the top of the brewer at the dispense fittings during this   inspection.   Operator Training   Review the operating procedures with whoever will be using the brewer.   Pay particular attention to the following areas:   1. Always pre-heat the dispensers before the first use of each day by   filling them half way with hot water, and letting them stand for at least   15 minutes.   2. Don't remove the brew basket until it has stopped dripping.   3. Make sure the dispenser is empty before brewing into it.   4. Show how to attach covers, close, and or secure the thermal   dispensers for transporting.   5. Show the location and operation of the water shut off valve as well as   the circuit breaker for the brewer.   6. Steam from the tank will form condensation in the vent tubes. This   condensation will drip into and then out of the brew baskets. 1/4 cup   discharging overnight is possible. Place an appropriate container   under each brew basket when not in use.   7. We recommend leaving the power to the brewer on overnight. The   water tank is well insulated and will use very little electricity to keep   the tank hot. Leaving the brewer in the on position will also avoid   delays at the beginning of shifts for the brewer to reach operating   temperature.   8 Operating Instructions   Control Panel Functions   Only switches that are active are illuminated.   Switches that are inactive or disabled are invisible.   X Main Power Switch    Controls all power to brewer    Indicator lamp at top of panel.   Y Control Panel On/Off Switch    Secondary power switch. Does not   disconnect main power.    Flashing = Off    Lit = On    Invisible = Main Power Off   Z Display    ”FIL” = Water tank is filling.    ”LO XXX” = Unit is heating, not   ready to brew. (XXX = actual   temperature)    ”NO BAS” = Brew basket not in   position.    Blank = Ready to brew.    Also displays error messages.   [ Stop Switches    Stops brew cycle    Lit = Brew cycle in progress    Invisible = Not brewing, or dripping   in progress   \ Brew Switches    Starts brew cycle    Must be held in for 1 second    Flashing = Brew cycle in progress    Lit = Ready to brew    Invisible – Not ready to brew, or   batch disabled   (See Programming Section)   ] Hot Water Switch    Dispenses hot water from faucet    Hold in to dispense   Brewing   1. Turn the main power switch and control   panel switch on.   7. When the brew cycle is finished, the STOP   button will extinguish and the BREW button will   continue flashing, indicating that coffee may still   be dripping from the bottom of the brew basket.   8. Before removing the brew basket or dispenser,   visually verify that dripping has stopped.   Notes:   2. Prepare a brew basket with the correct size   filter and appropriate amount of coffee.   3. Slide the brew basket completely into the   rails.   4. Place a clean, empty, preheated dispenser   under the brew basket.   5. Select a batch from the available choices,   and hold the corresponding BREW button in   for 1 second to start the brew cycle.   6. The STOP button will illuminate, and the   selected BREW button will flash, indicating   that brewing is in progress. All other BREW   buttons will extinguish.    Preheat dispenser by filling at least ½ full with   water at brewing temperature. Allow it to sit for   at least 15 minutes before draining.     A sensor will prevent the brewer from operating   if the brew basket is not all the way in.   A brew basket lock will prevent removal of the   brew basket during brewing and dripping   9 Programming   Display   Batch Settings    Turn the brewer off by pressing the main power switch.    Press the main power switch again to turn the unit on.   52   The last 2 digits of the model number will display briefly, then S t b.   S t b       Quickly hold the STOP button for 3 seconds.   The display will show the software version. Example:   Press STOP to continue.   P r G   0.0 4.8   Batches are numbered 1 – 3 (CBS-2051e) or 1 – 6 (CBS-2052e / 2052e20)   PARAMETER   BATCH #   SETTING   1.1 1.50   Example:   Left Side – Large Batch – Volume 1.5 Gal.    Next, the first batch parameter is displayed – batch 1, brew volume   Use the SCROLL UP and SCROLL DOWN buttons to adjust.   Press the STOP button to go to the next parameter – brew time.   1.1 1.50   1.2 4.00     Continue this way until all parameters are programmed for batch #1.   (See the chart below for an explanation of each parameter.)   Next, batch #2 programming begins.   2.0 OFF   Batches 2, 3, 5, and 6 may be disabled by leaving them set to “OFF”.   Change to “ON” to enable. Batches 1 and 4 cannot be disabled.    After all batches are programmed, go to temperature settings.   7 200   (See next page)   Important! After programming, you must press the HOT WATER button to save the settings and exit   programming mode, or changes will be lost. You may exit programming at any time.   Batch Parameters   X=Batch Number (1 - 6)   Parameter   Name   Range   Increment   Default Setting   Comment   X.0   Batch Enabled or   Disabled   On/Off   Batch 1 & 4 = ON   Batch 2, 3, 5, 6 = OFF be disabled.   Batch 1 & 4 cannot   X.1   Brew Volume   (Gallons)   0.25 – 3.00   0.01   1.5 gal. (2051e/2052e) To display liters, see   2.0 gal. (2052e20)   # 59 in Advanced   Settings section.   X.2   X.3   Brew Time (Min:Sec) 2:00 – 24:00   0:30   1%   4:00 minutes   0 %   Bypass Percent   0.00 – 40.0%   0.00 – 15.0%   0:10 – 5:00   Percentage of total   brew volume   Percentage of total   brew volume   The time between   prewetting and start   of brew cycle.   X.4   X.5   Prewet Percent   1%   0 %   Prewet Delay   (Min:Sec)   0:10   1:00 minute   X.6   Drip Delay (Min:Sec) 0:30 – 6:00   Minutes   0:10   1:30 minute   The time between   end of brew cycle   and unlocking of   brew basket.   10   Temperature Settings   Parameter   Name   Range   Default Setting   Comment   7 Inside tank. Will be slightly lower at   spray head. To display in ° Celsius,   see # 58 in Advanced Settings.   A= Faucet will dispense only when not   brewing.   On=Faucet always enabled.   Off=Faucet always disabled.   0=Will brew at any temperature   above 180°F.   Water Temp. (°F)   180°F - 208°F   200°F   8 9 Hot Water Service   A (auto) / On / Off   A (auto)   1 Brew at Set   Temperature   0 - 1   1=Will brew only at set temperature.   Note: Changes will not take effect   until one full brew cycle is   completed after the change is   made.   Parameter   Name   Range   Default Setting   Comment   10   Enter Advanced   Settings &   Diagnostics   0 - 1   0 0 = Skip Advanced Settings &   Diagnostics. Loop back to start of   batch programming cycle.   1 = Enter Advanced Settings &   Diagnostics.   Press STOP to continue   Important! To save your changes, press   to exit programming mode and return to operating mode.   Advanced Settings and Diagnostics   Address   Description   Water Level   in Tank   Range   Default   Comment   50   0 - 1   Tests if water is touching probe.   0 = Tank is less than full   1 = Tank is full   52   Brew Basket   Sensor State   (left / right)   Tank Temperature   Brewer Model   Number   0 - 1   To test, slide the brew basket in and out. Display   should toggle between 0 and 1.   0 = Brew basket out. 1 = Brew Basket in.   Displays current tank temperature.   Must be set for the correct model number of the   brewer: 51 for CBS-2051e,   55   56   180°F - 208°F   31 - 52   52 for CBS-2052e and CBS-2052e20.   Changes all settings to default factory settings.   0 = Do not reload defaults   57   Reload Defaults   0 - 1   0 1 = Reload all default settings   If 1 is selected, you must advance to the next   address for this change to take effect.   Does not change address 56 – model number.   F = Displays temp in degrees Fahrenheit   C = Displays temp in degrees Celsius   GAL = Displays volume in gallons   LTR = Displays volume in liters   58   59   Temperature Scale F or C   F Water Volume   Scale   GAL or LTR   GAL   11   Address   60   and   61   Description   Range   Default   Comment   Left Brew Valve   Flow Rate   Right Brew Valve   Flow Rate   0.09 – 1.49   If #59 is GAL   0.92   Use this to compensate for minor discrepancies in   actual volume versus programmed volume. Set   lower to increase volume, higher to decrease   volume. The following formula can be used to   determine the correct setting:   or   0.33 – 5.63   If #59 is LTR   0.28 – 0.38   If #59 is GAL   3.48   0.33   62   and   63   Left Bypass Valve   Flow Rate   Right Bypass   Valve Flow Rate   ACTUAL VOLUME   CURRENT   SETTING   NEW   SETTING   X = PROGRAMMED VOLUME   or   1.05 – 1.44   If #59 is LTR   0 - 1   1.24   0 64   65   Keypad Test   Tests function of control panel switches.   0 - Skip keypad test   1 - Keypad test active   Starting at the stop buttons, press each button   that is lit. The display will show the name of the   switch being pressed. Brew switches are named   S1, S2, S3, etc. The hot water switch must be   pressed last, as this will exit the test.   0 - Skip relay test. Loop back to #50   Relay Test   0 - 1   0 1 – Relay test active.   Press STOP to continue   Press   Press   to save the settings and exit Diagnostic mode.   again to exit Programming mode and return to Operating mode.   Relay Test   Warning: During these   tests, hot water may   be dispensed from   Tests the individual relays which control various components.   Use either batch button to actuate the relays.   the valve being tested.   To begin, you must first press the blinking Control Panel Power Switch.   Address   Description   Comment   90   91   92   93   94   95   Left or Single Brew Valve   Right Brew Valve   Left or Single Bypass Valve   Right Bypass Valve   Hot Water Faucet   Fill Valve   96   Heater   To protect the heaters, this test will work only if the tank is full.   97   98   Left or Single Brew Basket Lock   Right Brew Basket Lock   Press   to exit Relay Test.   Press   Press   again to exit Diagnostic mode.   again to exit Programming mode and return to Operating mode.   12   Error Codes   How to Clear Error   Codes   Code   Description   Possible Cause   Corrective Action   001   Internal Error   System had to reload   default settings.   Control board failure.   Clear error.   Turn main power   switch off and on.   Re-program the brewer to   the desired specifications. If   error occurs again, replace   control board.   050   051   075   Shorted temperature probe. Probe failure.   Replace probe.   Turn main power   switch off and on.   Turn main power   switch off and on.   Press the flashing   control panel power   switch to resume   operation.   Open temperature probe.   Bad probe connection, Check all connections.   or probe failure. Replace probe if necessary.   Brew basket lock or sensor Brew basket sensor or Repair or replace brew   failure.   lock has failed.   basket sensor or lock.   Basket was in place when   brew cycle started, but was   pulled out during the brew   cycle. If this error occurs,   the brew basket lock has   failed.   Magnet in brew basket Remove brew basket   handle is missing or   loose.   handle. Place magnet in   correct position.   100   101   102   Initial Fill Error   Initial fill time was more   than 15 minutes.   Water supply flow rate Watch for short potting   Press the control   panel power switch.   is too low.   during brew cycle.   Investigate cause of low flow   rate. (Clogged water filter,   etc.)   Error on refill   Tank did not refill within 3   minutes.   Water supply flow rate Watch for short potting   Error message is   cleared   is too low.   during brew cycle.   Investigate cause of low flow automatically at   rate. (Clogged water filter,   etc.)   end of brew cycle.   Unwanted Fill   Possible leak in tank,   fitting, or valve.   Check inside of machine for   leaks.   Turn main power   switch off and on.   When brewer is idle, the fill   valve was activated for   more than 30 seconds   during a 1 hour period.   Output on control   board has failed,   causing a dispense   valve to open.   Replace control board.   200   201   Flat Line Temperature   (Water is boiling)   System is calling for heat,   but the temperature does   not rise at least 2°F within   10 minutes.   Triac is stuck closed,   bad output on control   board, or temperature   is set too high for   altitude.   Check triacs, check control   board output, or adjust   temperature for altitude.   Turn main power   switch off and on.   Heater Open   Heating element   failure.   Check and replace heating   elements if necessary.   Turn main power   switch off and on.   System is calling for heat,   but the temperature does   not rise at least 2°F within   10 minutes. This error is   disabled during brewing   and while using the hot   water faucet.   202   255   Heater Short   Possible triac stuck   closed, or bad output   on control board.   Check triac and control   board.   Enter programming   mode, then exit   programming   mode.   Turn main power   switch off and on.   System is not calling for   heat, but temperature rises   more than 5°F.   Keypad Error   A switch was pressed for   more than 45 seconds.   Switch was held in too Clear error and try again. If   long, or switch is stuck error occurs without switch   closed.   being pressed, replace input   board.   13   Parts   Figure 1 – CBS-2051e Main Assembly   DWG 101191-B   ITEM #   QTY   1 1 PART # DESCRIPTION   1 2 2 3 4 5 6 7 8 9 10   11   11   11   12   13   14   15   16   17   001049 WELDMENT CBS-2051e   57006 FILL VALVE, S-53 120VAC   57017 FILL VALVE, S-53 220VAC   24012 GASKET, S-53 FILL VALVE   31078 FITTING, S-53 FILL VALVE INLET   03074 BRACKET, S-53   82020 SCREW, S-53 FILL VALVE   31031 FITTING, 90° MALE ELBOW, 3/8 TUBE OD X 3/8 MPT   86040 CONNECTOR, CABLE CLAMP, 3/4"   86032 BUSHING, SNAP, 1" MOUNTING HOLE DIA   29020 SPACER, HOT WATER VALVE   102192 ASSEMBLY, HOT WATER VALVE, 120VAC   102193 ASSEMBLY, HOT WATER VALVE, 220VAC   EXPORT   220V ONLY   1 1 1 1 4 1 1 2 2 1 1 EXPORT   220V ONLY   57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)   83051 WASHER, #8 SCREW SIZE, FLAT   4 20   1 1 1 84002 NUT, HEX, #8-32 MACHINE SCREW   002065 WELDMENT, HOT WATER FAUCET   33007 LOCKNUT, 7/16 STRAIGHT PIPE THREAD   108003 SWITCHING/ CONTROL BOARD, 6 KEYS, S3P   46029 LABEL, POWER SWITCH   1 14   18   19   20   20   21   22   23   24   25   26   27   28   28   29   29   30   31   32   32   32   33   34   35   35   35   36   37   38   39   40   41   42   43   44   45   46   47   48   49   50   51   52   53   54   55   56   58   59   60   61   62   63   64   4 4 1 1 4 1 1 12   1 1 1 1 1 1 1 1 1 1 1 15007 STANDOFF, MALE-FEMALE, THREADED HEX 4-40-1/2"   29007 NUT, #4-40 KNURLED THUMB   51042 BOARD, POWER SUPPLY-120VAC   51055 BOARD, POWER SUPPLY-220VAC   29019 SPACER, .25" HEX x 1" LG., FEM, #4-40 THREAD   65002 CONNECTOR, COPPER LUG   52050 TERMINAL BLOCK   83026 WASHER, INTERNAL TOOTH LOCK, #8 SCREW SIZE,   104029 ASSEMBLY, TANK CBS-2051e   22057 INSULATION TANK FRONT CBS-2051   22058 INSULATION TANK REAR CBS-2051   102102 ASSEMBLY, LARGE SPRAY HEAD, 120V (SEE FIG. 5)   102159 ASSEMBLY, LARGE SPRAY HEAD, 220V (SEE FIG. 5)   101160 ASSEMBLY, BREW BASKET LOCK. 120 VAC   101174 ASSEMBLY, BREW BASKET LOCK. 220 VAC   102147 WELDMENT, BRACKET BY-PASS VALVE   102207 ASSEMBLY, REED SWITCH   57044 VALVE, BYPASS LEFT 120 VAC   57077 VALVE, BYPASS LEFT 220 VAC   57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)   84030 LOCKNUT, #8-32 SCREW SIZE, HEX THIN NYLON INSERT   45081 OVERLAY, CBS-2051e   102189 ASSEMBLY, POWER BRACKET, CBS-2000e   52026 CIRCUIT BREAKER, 5A   EXPORT   220V ONLY   EXPORT   220V ONLY   EXPORT   220V ONLY   EXPORT   220V ONLY   2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6 1 1 3 1 1 1 1 1 2 1 1 1 1 11   1 4 1 58054 SWITCH, PUSH BUTTON   25090 TUBE, 5/8"OD X 3/8"ID X 17"LG, COLD WATER   25044 TUBE, 5/8"OD X 3/8"ID X 7.5"LG, BY-PASS   25042 TUBE, 1/2"OD X 1/4"ID X 7 1/2" LG, VENT   25104 TUBE, 1/4"X11/8"X25"LG, VENT HOT WATER VALVE   25105 TUBE, 5/8"OD X 3/8"ID X 2.5"LG, HOT WATER VALVE OUTLET   25106 TUBE, 5/8"OD X 3/8"ID X 11"LG, HOT WATER VALVE INLET   25045 TUBE, 31/32"OD X 5/8"ID X 4 1/4" LG, BREW   25046 TUBE, 5/8"OD X 3/8"ID X 15"LG, DRAIN   25060 TUBE 5/8"OD X 3/8"ID X 1.5"LG, BY-PASS   25061 TUBE 1/2"OD X 1/4"ID X 1/2""LG, BY-PASS   86007 CLAMP, HOSE, .593"-.656" DIA RANGE   86036 CLAMP, HOSE, .875"-1.0" DIA RANGE   86039 CLAMP, HOSE, 1.031"-1.187" DIA RANGE   86038 CLAMP, HOSE, .670"-.780" DIA RANGE   402016 HARNESS, ELECTRICAL, MAIN CBS-2051e   402030 HARNESS, ELECTRICAL, TWO HEATER WIRE SET CBS-2051e   102202 ASSEMBLY, WATER LEVEL PROBE, CBS-2040, -50e   102172 ASSEMBLY, PROBE DIGITAL TEMPERATURE 8.0" LG   41016 LABEL, EXTRACTOR   44024 LABEL, WARNING-HIGH VOLTAGE   44004 LABEL GROUND   01501 COVER, UPPER BASE CBS-2051e   102194 ASSEMBLY, RIGHT COVER CBS-2050e'S   01502 COVER, TOP CBS-2051e   82059 SCREW, #8-32 X 3/8 TRUSS HD PHIL., MACHINE   401213 WIRING DIAGRAM, CBS-2051 UNIV. WIR. 1PH, 3WIR+GR, 2 HEAT.   73011 LEG, FLANGE FOOT, 4" HIGH   101165 ASSEMBLY, BREW BASKET, 16" X 6", DIA HOLE 0.280" (SEE FIG.6)   15   Figure 2 – CBS-2051e Tank Assembly   DWG 104029-C   ITEM #   1 QTY   1 PART # DESCRIPTION   4039 WELDMENT, TANK CBS-2051e   2 3 4 5 6 7 1 1 1 1 1 1 83041 WASHER, .812"OD X .412"ID, FLAT   31005 FITTING, 90 ELBOW, 1/4 HOSE ID X 1/8 MPT   31116 LOCKNUT 1/8 STRAIGHT PIPE THREAD   83043 WASHER, 1.125"OD X 0.688"ID FLAT   83048 WASHER, 1.250"OD X 0.835"ID FLAT   31077 FITTING, 3/8 HOSE ID X 3/8 MPT   8 1 31150 FITTING, 5/8 HOSE ID X 1/2 MPT   9 1 1 3 2 1 1 1 2 31118 LOCKNUT 3/8 STRAIGHT PIPE THREAD   31151 LOCKNUT 1/2 STRAIGHT PIPE THREAD   31021 BUSHING, 3/4-16 X 1/4 NPSM, HEX HEAD   107002 HEATER ASSY., 3000W, 240VAC   84007 NUT, 3/4-16 HEX JAM   31152 VALVE, COMPR 3/8 TUBE OD X 1/4 MPT   13055 TUBE, VALVE DRAIN , 3/8" OD X .035"TH X 1.5" LG   31128 FITTING, 90° ELBOW, 3/8 HOSE ID X 1/4 MPT   31027 FITTING, COMPR 90° MALE ELBOW, 3/8 TUBE OD X 1/4 MPT   10   11   12   13   14   15   16   17   1 16   18   19   20   21   22   23   24   25   26   27   28   29   30   31   1 3 1 3 1 1 1 1 2 2 8 8 2 2 13072 OUTLET, INSIDE TANK HOT WATER   83042 WASHER, .875"OD X .562"ID, FLAT   31036 FITTING COMPR. MALE CONNECTOR 1/4 TUBE OD X 1/4 MPT   31117 LOCKNUT 1/4 STRAIGHT PIPE THREAD   25098 FITTING, COMPRESSION MALE CONNECTOR   31081 PLUG, HEX HEAD 1/4" MPT   24002 O-RING, TANK COVER   102013 ASSEMBLY, TANK COVER   3332 BRACKET 2, ONE SHOT THERMOSTAT   53064 THERMOSTAT, SINGLE SHOT,TRIAC   83011 WASHER, #6 SCREW SIZE, INTERNAL   84001 NUT, HEX, #6-32 MACHINE SCREW   3297 SINK, HEAT FOR 40A TRIAC   59008 TRIAC 40A, 600V   17   Figure 3 – CBS-2052e / 2052e20 Main Assembly   DWG 101197-B   ITEM #   QTY   2 2 2 1 1 1 1 1 PART # DESCRIPTION   2 3 4 5 5 5 6 7 8 86021 BUSHING, SNAP, 1.375 MTG HOLE   86018 PLUG, DOME, 1.375 MOUNTING HOLE   86032 BUSHING, SNAP, 1" MOUNTING HOLE DIA   102189 ASSEMBLY, POWER BRACKET, CBS-2000e   52026 CIRCUIT BREAKER, 5A   58054 SWITCH, PUSH BUTTON   102104 ASSEMBLY, TERMINAL BLOCK   65002 CONNECTOR, COPPER LUG   57001 FILL VALVE ASSY., S-45, 120VAC   57022 FILL VALVE ASSY., S-45, 220VAC   83026 WASHER, INTERNAL TOOTH LOCK, #8 SCREW SIZE,   84002 NUT, HEX, #8-32 MACHINE SCREW   108005 SWITCHING / CONTROL BOARD,10 KEYS, D3P (CBS-2052e)   108065 SWITCHING / CONTROL BOARD,10 KEYS, D3P (CBS-2052e20)   29007 NUT, #4-40 KNURLED THUMB   15007 STANDOFF, MALE-FEMALE, THREADED HEX 4-40-1/2"   51042 BOARD, POWER SUPPLY-120VAC   51055 BOARD, POWER SUPPLY-220VAC   29019 SPACER, .25" HEX x 1" LG., FEM, #4-40 THREAD   29020 SPACER, HOT WATER VALVE   1 EXPORT   220V ONLY   8 9 1 18   32   1 1 9 4 1 1 2 10   12   12   13   14   15   15   16   17   18   EXPORT   220V ONLY   2 1 102192 ASSEMBLY, HOT WATER VALVE, 120VAC   18   EXPORT   220V ONLY   18   18   19   20   21   22   23   24   24   25   26   27   27   27   28   28   28   29   29   30   31   32   33   34   34   35   36   37   38   39   40   41   42   43   44   45   46   47   48   49   50   51   52   53   54   55   56   58   58   59   60   61   64   1 102193 ASSEMBLY, HOT WATER VALVE, 220VAC   57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)   102202 ASSEMBLY, WATER LEVEL PROBE, CBS-2040, -50e   83051 WASHER, #8 SCREW SIZE, FLAT   002065 WELDMENT, HOT WATER FAUCET   33007 LOCKNUT, 7/16 STRAIGHT PIPE THREAD   45082 OVERLAY, CBS-2052e   102102 ASSEMBLY, LARGE SPRAY HEAD, 120V (SEE FIG 5)   102159 ASSEMBLY, LARGE SPRAY HEAD, 220V (SEE FIG 5)   102147 WELDMENT, BRACKET BY-PASS VALVE   46029 LABEL, POWER SWITCH   57043 VALVE, BYPASS RIGHT 120 VAC   57076 VALVE, BYPASS RIGHT 220 VAC   57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)   57044 VALVE, BYPASS LEFT 120 VAC   57077 VALVE, BYPASS LEFT 220 VAC   57073 VALVE REBUILD KIT, DSV11. (PLUNGER, SPRING, AND DIAPHRAGM)   101160 ASSEMBLY, BREW BASKET LOCK. 120 VAC   101174 ASSEMBLY, BREW BASKET LOCK. 220 VAC   22036 INSULATION-FRONT, TANK CBS-2052   1 6 1 1 1 2 2 2 1 1 1 EXPORT   220V ONLY   EXPORT   220V ONLY   1 1 EXPORT   220V ONLY   2 2 1 1 1 4 1 1 4 1 2 2 2 2 2 1 1 5 2 2 2 1 1 1 1 1 2 1 1 1 1 1 1 11   2 3 EXPORT   220V ONLY   22037 INSULATION, TANK-BACK CBS-2052   104026 ASSEMBLY, TANK CBS-2052e (SEE FIG. 4)   84030 LOCKNUT, #8-32 SCREW SIZE, HEX THIN NYLON INSERT   32050 TUBE, COLD WATER (CBS-2052e)   13122 TUBE, COLD WATER (CBS-2052e20)   86007 CLAMP, HOSE, .593"-.656" DIA RANGE   25046 TUBE, 5/8"OD X 3/8"ID X 15"LG, DRAIN   25045 TUBE, 31/32"OD X 5/8"ID X 4 1/4" LG, BREW   25044 TUBE, 5/8"OD X 3/8"ID X 7.5"LG, BY-PASS   25042 TUBE, 1/2"OD X 1/4"ID X 7 1/2" LG, VENT   25060 TUBE 5/8"OD X 3/8"ID X 1.5"LG, BY-PASS   25061 TUBE 1/2"OD X 1/4"ID X 1/2""LG, BY-PASS   25106 TUBE, 5/8"OD X 3/8"ID X 11"LG, HOT WATER VALVE INLET   25105 TUBE, 5/8"OD X 3/8"ID X 2.5"LG, HOT WATER VALVE OUTLET   86038 CLAMP, HOSE, .670"-.780" DIA RANGE   86036 CLAMP, HOSE, .875"-1.0" DIA RANGE   86039 CLAMP, HOSE, 1.031"-1.187" DIA RANGE   102207 ASSEMBLY, REED SWITCH   102172 ASSEMBLY, PROBE DIGITAL TEMPERATURE 8.0" LG   44019 LABEL, SINGLE PHASE CONFIGURATION   402013 HARNESS ELECTRICAL, CBS-2052e, (THREE HEATERS)   402028 HARNESS, ELECTRICAL, THREE HEATER WIRE SET. CBS-2052e   44022 LABEL, CONNECTION WARNING FOR 3 PH   44024 LABEL, WARNING-HIGH VOLTAGE   102202 ASSEMBLY, WATER LEVEL PROBE, CBS-2040, -50e   01445 COVER, TOP CBS-2052e   01446 COVER, UPPER BASE CBS-2052e   102194 ASSEMBLY, RIGHT COVER (CBS-2050e)   102286 ASSEMBLY, RIGHT COVER (CBS-2050e20)   46027 LABEL, SPRAY HOUSING   82059 SCREW, #8-32 X 3/8 TRUSS HD PHIL., MACHINE   101165 ASSEMBLY, BREW BASKET, 16" X 6", 0.280" HOLE (SEE FIG 6)   73011 LEG, FLANGE FOOT, 4" HIGH   19   Figure 4 – CBS-2052e / 2052e20 Tank Assembly   DWG 104026-A   ITEM #   1 QTY   1 3 1 1 1 1 2 1 1 2 2 2 2 2 2 2 2 2 3 1 PART # DESCRIPTION   004038 WELDMENT, TANK CBS-2052e   31021 BUSHING, 3/4-16 X 1/4 NPSM, HEX HEAD   84007 NUT, 3/4-16 HEX JAM   31082 FITTING, HEX NIPPLE, 3/8 MPT X 1/4 MPT   34004 VALVE, BALL 3/8 FPT X 3/8 FPT   31054 FITTING, 1/2 HOSE ID X 3/8 MPT   31027 FITTING, COMPR 90° MALE ELBOW, 3/8 TUBE OD X 1/4 MPT   31128 FITTING, 90° ELBOW, 3/8 HOSE ID X 1/4 MPT   13072 OUTLET, INSIDE TANK HOT WATER   83048 WASHER, 1.250"OD X 0.835"ID FLAT   83043 WASHER, 1.125"OD X 0.688"ID FLAT   31150 FITTING, 5/8 HOSE ID X 1/2 MPT   2 3 4 5 6 7 8 9 10   11   12   13   14   15   16   17   18   19   20   31077 FITTING, 3/8 HOSE ID X 3/8 MPT   31151 LOCKNUT 1/2 STRAIGHT PIPE THREAD   31118 LOCKNUT 3/8 STRAIGHT PIPE THREAD   83041 WASHER, .812"OD X .412"ID, FLAT   31005 FITTING, 90° ELBOW, 1/4 HOSE ID X 1/8 MPT   31116 LOCKNUT 1/8 STRAIGHT PIPE THREAD   83042 WASHER, .875"OD X .562"ID, FLAT   25098 FITTING, COMPRESSION MALE CONNECTOR   20   21   22   23   24   25   26   27   28   28   29   30   31   32   1 3 3 12   12   3 1 3 3 3 31036 FITTING COMPR. MALE CONNECTOR 1/4 TUBE OD X 1/4 MPT   03332 BRACKET 2, ONE SHOT THERMOSTAT   53064 THERMOSTAT, SINGLE SHOT,TRIAC   83011 WASHER, #6 SCREW SIZE, INTERNAL   84001 NUT, HEX, #6-32 MACHINE SCREW   31117 LOCKNUT 1/4 STRAIGHT PIPE THREAD   31081 PLUG, HEX HEAD 1/4" MPT   107002 HEATER ASSY., 3000W, 240VAC   107018 HEATER ASSY., 5000W, 240VAC   03297 SINK, HEAT FOR 40A TRIAC   3 1 1 59008 TRIAC 40A, 600V   24002 O-RING, TANK COVER   102013 ASSEMBLY, TANK COVER   21   Figure 5 – Spray Housing Assembly, 120 VAC, Part # 102102   Spray Housing Assembly, 220 VAC, Part # 102159 (EXPORT ONLY)   ITEM #   QTY   4 PART # DESCRIPTION   1 2 82112 #8 X 3/4'' PAN HD. PHIL. T.S. 18-8 S.S. SCREW   57042 VALVE ASSY., DSV-10, 120 VAC   1 EXPORT   220V ONLY   2 3 4 5 6 1 1 1 1 1 57075 VALVE ASSY., DSV-10, 240 VAC   57072 VALVE REBUILD KIT, DSV-10   102113 SPRAY HOUSING ASSY.   24035 O-RING, 5.5 I.D. X 5 11/16 O.D. X 3/32   102108 SPRAY PLATE ASSY., 5 7/8" DIA.   22   Figure 6 – Brew Basket Assembly, 16” X 6”, Part # 101165   ITEM   QTY   PART # DESCRIPTION   1 1 1 82096 HANDLE SCREW   BREW BASKET HANDLE, BLACK   2 3 23117   (includes magnet)   1 1 9006 WIRE INSERT, 16 X 6   46011 WARNING LABEL   NOT   SHOWN   NOT   SHOWN   PAPER FILTERS, 15” X 5.5”   500 PER CASE   F001   COLOR BREW BASKET HANDLES   PART # DESCRIPTION   23106 BREW BASKET HANDLE, GREEN   23107 BREW BASKET HANDLE, ORANGE   23148 BREW BASKET HANDLE, RED   23   |