				CONGRATULATIONS   
					® 
					Congratulations on your purchase of the Acclaim USB Only Intraoral Digital   
					Video Camera System, the latest camera in the dental video imaging product line   
					from Air Techniques, a leading manufacturer of dental and veterinary equipment   
					since 1962.   
					The Acclaim USB Only Camera System design offers the flexible benefits of USB   
					Plug-N-Play technology that is easily integrated into any practice. The very light-   
					weight one-piece toothbrush-size Acclaim Camera Handpiece is an extremely   
					® 
					maneuverable instrument, which produces crisp, clear images. The Acclaim USB   
					Only Intraoral Digital Video Camera System is hereafter referred to as the Acclaim   
					System in this manual.   
					Review and follow the guidelines included in this Operator’s Manual to ensure   
					that your Acclaim System gives you the highest level of service.   
					For product support and information on how to expand your Acclaim System,   
					contact your authorized Air Techniques dealer.   
					WARRANTY   
					This Air Techniques equipment is warranted to be free from defects in material   
					and workmanship from the date of installation for a period of 3 years.   
					Any item returned to our factory through your authorized Air Techniques dealer,   
					will be repaired or replaced at our option at no charge provided that our inspec-   
					tion shall indicate it to have been defective. Dealer labor, shipping and handling   
					charges are not covered by this warranty.   
					This warranty does not apply to damage due to shipping, misuse, careless han-   
					dling or repairs by other than authorized service personnel. Warranty void if   
					installed or serviced by other than your authorized Air Techniques dealer service   
					personnel. Air Techniques, Inc. is not liable for indirect or consequential damage   
					or loss of any nature in connection with this equipment.   
					This warranty is in lieu of all other warranties expressed or implied. No represen-   
					tative or person is authorized to assume for us any liability in connection with the   
					sale of our equipment.   
					ON-LINE WARRANTY REGISTRATION   
					Quickly and easily register your new Acclaim Camera on-line. Just have your   
					product model and serial numbers available. Then go to either the Air   
					
					
					warranty link   
					, click the   
					and complete the registration form.   
					This on-line registration ensures a record for the warranty period and helps us   
					keep you informed of product updates and other valuable information.   
					3 
				SAFETY NOTICE   
					GENERAL   
					This equipment has been designed to minimize exposure of personnel to hazards.   
					While the Acclaim System is designed for safe operation, certain precautions must   
					be observed. Use of the Acclaim System not in conformance with the instructions   
					specified in this manual may result in permanent failure of the unit.   
					KNOWLEDGE OF WARNINGS AND CAUTIONS   
					Users must exercise every precaution to ensure personnel safety, and be familiar   
					with the warnings and cautions presented throughout this manual and summa-   
					rized below.   
					CAUTION: There are no user-serviceable parts inside. Servicing should be   
					performed by qualified dealer service representatives only.   
					K Connecting any device to the Acclaim System that does not meet the equiv-   
					alent safety requirements of the system may reduce the safety effectiveness   
					of the Acclaim System.   
					K Unplug the system components from power before performing cleaning   
					procedures.   
					WARNING: To prevent fire or electrical shock, do not expose this equipment   
					to rain or moisture.   
					K Do not spray cleaning liquids or disinfectants directly on the camera hand-   
					piece or the USB Umbilical. Use care not to allow liquids to run into inter-   
					nal circuitry.   
					K Do not wipe the surfaces using benzine, thinner, etc. as this may degrade   
					the finish.   
					DO NOT ATTEMPT INTERNAL SERVICE   
					The interior of each component of the Acclaim System is only accessible by   
					removing hardware with tools and should only be opened and serviced by an   
					authorized service technician. Please contact your local authorized dealer for   
					service. Failure to heed this warning may result in equipment damage and void-   
					ing the warranty.   
					Markings.   
					The following terms or symbols are used on the equipment or in this manual   
					to denote information of special importance:   
					Alerts users to important Operating   
					and Maintenance instructions. Read   
					carefully to avoid any problems.   
					Indicates type B equipment   
					in accordance with IEC   
					60601-1   
					Alerts users that the infection control sheath must be   
					used for only one patient and disposed of properly in   
					accordance with local code.   
					2 
					ATTENTION USERS:   
					Manufacturing date code on serial number label is in the format:MONTH YYYY.   
					4 
				SAFETY NOTICE   
					Use of Accessory Equipment.   
					The use of ACCESSORY equipment not complying with the equivalent safety   
					requirements of this equipment may lead to a reduced level of safety of the   
					resulting system. Consideration relating to the choice shall include:   
					Use of the accessory in the PATIENT VICINITY   
					Evidence that the safety certification of the ACCESSORY has been   
					performed in accordance to the appropriate IEC 60601-1 and/or IEC   
					60601-1-1 harmonized national standard.   
					Use of ACCESSORIES or cables other than those specified or provided by Air   
					Techniques or its ALLPRO Imaging division may result in increased EMISSIONS   
					or decreased IMMUNITY of the EQUIPMENT.   
					IMPORTANT INFORMATION   
					General Notes.   
					K All instructions in this manual form an integral part of the unit. They must   
					be kept close to the unit and in readiness whenever required. Precise   
					observance of these instructions is a pre-condition for use of the unit for   
					the intended purpose and for its correct operation. This manual should be   
					passed on to any future purchaser or operator.   
					K Safety of the operator as well as trouble-free operation of the unit are only   
					ensured if use is made of original equipment parts. Moreover, use may   
					only be made of those accessories that are specified in the technical   
					documentation or that have been expressly approved and released by the   
					manufacturer for the intended purpose. The manufacturer cannot warranty   
					for the safety or proper functioning of this unit in the case where parts or   
					accessories are used that are not supplied by the manufacturer.   
					K There is no guarantee against damage arising where parts or accessories   
					are used that are not supplied by the manufacturer.   
					K Observe the usage and storage conditions.   
					K The Acclaim System may only be operated using authorized software.   
					K The manufacturer regard themselves as being responsible for the equipment   
					with regard to safety, reliability and proper functioning only if assembly,   
					resetting, changes or modifications and repairs have been carried out by   
					an authorized dealer and if the equipment is used in conformity with the   
					instructions contained in this manual.   
					K The device conforms to the relevant safety standards valid at this time.   
					K Any reprinting of the technical documentation, in whole or in part, is subject   
					to prior written approval by the manufacturer.   
					Incorrect Usage   
					K Any use that is not described in this manual as correct usage is considered   
					as incorrect usage. The manufacturer is not to be held liable for any damage   
					caused as a result of incorrect usage. The operator bears all risks.   
					5 
				KEY PARTS IDENTIFICATION   
					The Acclaim System is comprised of a Camera Handpiece and USB Umbilical.   
					Each is boxed separately along with associated accessories and is available   
					individually by their selling numbers A5520 and A5550 respectively. When   
					shipped together as a complete Acclaim System, the sperate boxes are packed   
					in a single box as selling number A5500. The following lists the components   
					included with the Acclaim System.   
					A5520 Camera Handpiece box includes:   
					Item   
					Qty   
					Camera Handpiece   
					1 
					Disposable Infection Control Sheaths   
					Sample Pack for Camera Handpiece   
					20   
					1 
					Camera Handpiece Instruction Sheet   
					Part Number A5537   
					A5550 USB Umbilical box includes:   
					Item   
					Qty   
					1 
					USB Umbilical   
					(with embedded USB 2.0 interface   
					control module)   
					Camera Handpiece Holder   
					Part Number A5145   
					1 
					1 
					Operator’s Manual   
					CD containing -   
					Part Number A5551   
					Part Number A5552   
					WDM video drivers for DirectX 9 compli-   
					ant streaming video capture software   
					applications.   
					1 
					USB Video Diagnostic Software   
					PDF version of Operator’s Manual   
					6 
				COMPONENT DESCRIPTION   
					The Acclaim System is an intraoral camera system designed for dental and   
					veterinary applications that consists of the Camera Handpiece, Camera   
					Handpiece Holder and the USB Umbilical as described below.   
					NOTE:   
					Air Techniques’ VISIX Imaging Software is fully compatible with the Acclaim   
					System. Contact your authorized Air Techniques dealer to acquire VISIX.   
					Camera Handpiece - The Camera Handpiece is extremely lightweight with a   
					high resolution, high sensitivity, auto-exposure controlled CCD sensor and a   
					high performance lens system illuminated by ultra-bright white LED lamps. The   
					fixed focus lens has a broad depth of field bringing all objects measuring   
					between 6 and 50 mm into focus enabling the camera to finely detail a section   
					of a single tooth to a full smile. The Camera Handpiece has the rich look and   
					tactile feel of a metallic handpiece and provides 2 keypad buttons for fingertip oper-   
					ating control of the system. The specific functions performed by the keypad   
					buttons depend on the user-supplied compatible streaming video capture soft-   
					ware application used.   
					Camera Handpiece Holder - The Camera Handpiece Holder can be   
					fastened in a convenient location for safe storage of the Camera Handpiece   
					when it is not in use. In addition to storage, the Camera Handpiece Holder   
					also has built-in magnet that turns off the Camera Handpiece power. This   
					feature conserves energy and equipment wear so the camera is ready and   
					operational when needed.   
					USB Umbilical - An overall 13.5-foot cable assembly comprised of an USB   
					2.0 high speed interface control module with an associated 4-foot USB 2.0   
					cable and a 9-foot control umbilical. The USB 2.0 cable is terminated with a   
					Type A USB connector while the control umbilical uses a quick-disconnect con-   
					nector. The USB Umbilical connects between the Camera Handpiece and the   
					user’s computer and provides a digital video output for use with a PC with user-   
					supplied compatible streaming video capture software application.   
					UNPACKING AND INSPECTION   
					Unpack each component of the Acclaim System and inspect for physical   
					damage such as scratched panels, damaged connectors, etc. If any damage is   
					noted, immediately notify your Air Techniques authorized dealer immediately so   
					corrective action can be taken.   
					Make sure to save all packaging material in case repackaging and shipment is   
					necessary.   
					Verify that all listed items were received. If any item is missing, notify your Air   
					Techniques authorized dealer.   
					7 
				PRE-INSTALLATION INFORMATION   
					IMPORTANT:   
					When operating the Acclaim System connected to the USB port on a   
					Computer System, the computer must be loaded with Air Techniques   
					Authorized DirectX 9 compliant streaming video software application   
					and authorized imaging software such as VISIX. Contact your dealer   
					for available Computer Systems and software options.   
					NOTE:   
					VISIX Imaging Software is fully compatible with Acclaim Systems.   
					Minimum Computer System Requirements - The Computer System (lap-   
					top or computer, monitor, etc.) and any related peripheral or other equipment,   
					supplied by the user, or a third party, must comply with the requirements for   
					accessory Equipment as specified in the appropriate IEC 60601-1 and/or IEC   
					60601-1-1 harmonized national standard.   
					Unless otherwise stated, the components of the computer system must comply   
					with the minimum requirements listed below.   
					CPU Speed:   
					Pentium-4, 2 GHz or higher   
					Operating System:   
					Windows 2000 Service Pack 4 or Windows   
					XP Service Pack 1 with Microsoft knowledge   
					base KB822603 update   
					DirectX 9 compliant streaming video   
					software application installed   
					System RAM:   
					CD ROM Drive:   
					Monitor :   
					256 MB   
					24X or higher   
					SVGA 17" with 800 x 600 resolution or   
					higher   
					Video Display Adapter:   
					USB Port:   
					16 MB video card with 800 x 600 pixel   
					resolution and 32-bit color   
					Must be USB 2.0 high speed, high power   
					port   
					System Properties.   
					If unsure of the operating system version installed,   
					check that it meets the necessary requirements by   
					checking the System Properties window.   
					This is done simply by right clicking the My Computer   
					icon. Selecting Properties from the menu list displays the   
					System Properties   
					window as shown. The installed oper-   
					General Tab.   
					ating system version is listed under the   
					System Properties window can also be displayed   
					The   
					from the Desktop Start button. Just press the Start button   
					and select SettingsꢀControl Panel and then System.   
					8 
				HANDPIECE KEYPAD BUTTON FUNCTIONS   
					1 
					2 
					3 
					Acclaim Camera   
					Handpiece   
					A5520   
					Keypad Buttons - Each keypad button provides the Acclaim Camera   
					Handpiece fingertip control over the PC streaming video capture software via the   
					USB Umbilical. The specific functions performed by the keypad buttons depend   
					on a software installation that supports the 2-button handpiece. Typical keypad   
					actions provided below.   
					NOTE:   
					Simultaneously depressing both keypad buttons for approximately 3 seconds   
					deactivates the Camera Handpiece LED light source. This is commonly used   
					when imaging an X-ray on a light box.   
					(1) Top Keypad Button   
					Sends a Button 1 command to the PC.   
					While the specific function performed   
					depends on the setting of the video capture   
					software application installed on the PC,   
					this command typically freezes and   
					unfreezes the image that is displayed on the   
					computer monitor. (Press to go live. Release   
					to freeze.)   
					(2) Bottom Keypad Button   
					(3) Handpiece Connector   
					Sends a Button 2 command to the PC.   
					While the specific action depends on the   
					video capture software installed, it typically   
					saves the image displayed on the computer   
					monitor to the computer hard disk.   
					An 8-pin connector socket that accepts   
					connection of the keyed 8-pin quick   
					disconnect plug end of the USB   
					Umbilical.   
					9 
				SYSTEM SETUP   
					Installing the Acclaim System is as simple as making the necessary connections   
					of the USB Umbilical between a PC loaded with an Air Techniques Authorized   
					DirectX 9 compliant user-supplied streaming video software application such as   
					VISIX and the Camera Handpiece. Perform the following procedures to set up the   
					Acclaim System.   
					Notes: Authorized Imaging Software, such as VISIX, supplied by the dealer or other   
					company, must be installed on the computer in order to operate the Acclaim   
					System.   
					A Microsoft® Driver Not Signed statement may appear. If it does, click   
					Continue to proceed with installation.   
					WDM Driver Installation - Before connecting the Acclaim System to your   
					computer or attempting to use it for the first time, run the Setup program on the   
					Acclaim System Drivers and Utilities Disk included with the Acclaim System. The   
					supplied CD provides the WDM drivers needed to communicate between the   
					Acclaim System and the associated user-supplied USB streaming video software   
					application installed on the PC computer system. Normally, this program runs   
					automatically when the CD is inserted into the drive for the first time. If not, run the   
					setup program located in the root directory of the CD (typically D:\Acclaim. msi).   
					The Setup program guides the user through updating the computer library files,   
					which must be completed before the Acclaim System will operate properly. More   
					information can be found in the Installation Instructions and Notes file on the   
					Acclaim System Drivers and Utilities Disk included with the system.   
					Do not use the A5020 Camera Handpiece (blue and white plastic). Only the A5520   
					Camera Handpiece (metallic) can be used with the USB Only Acclaim System.   
					Do not twist or turn the cable connectors. The USB Umbilical connector is keyed   
					and mates straight on with the A5520 Handpiece connector.   
					Camera Handpiece Connection - Carefully connect the A5520 Camera   
					Handpiece to the supplied USB Umbilical as follows:   
					Connector   
					1. Using the gray molded connector   
					Key   
					end of the USB Umbilical, align   
					the connector key with the keyway   
					of the Handpiece connector.   
					2. Insert straight into Handpiece   
					connector until it securely snaps   
					into place.   
					Camera   
					Handpiece   
					Camera Handpiece Connection   
					(A5520 only)   
					10   
				SYSTEM SETUP   
					USB Interface Connection - Connect the USB Type A connector side of the   
					USB Umbilical to any available USB 2.0 High Speed port on the user supplied   
					use the same USB port   
					Computer System. Always make sure to   
					nection of the USB cable is necessary.   
					whenever recon-   
					Computer   
					USB Port   
					USB Type A   
					Connector   
					USB   
					Umbilical   
					USB Interface Connection   
					Use care when adhering the handpiece holder to selected surface.   
					The double-sided adhesive fastens quickly and permanently.   
					Camera Handpiece Holder Installation - Using the supplied double-   
					sided adhesive fastener, the Camera Handpiece Holder, part number A5145,   
					can be fastened to any convenient location for safe storage of the USB Umbilical   
					or Camera Handpiece when not in use.   
					Install the Camera Handpiece Holder as follows:   
					1. Remove the protective film from the double-sided adhesive on the   
					Handpiece Holder   
					2. Attach the Camera Handpiece Holder to a flat, clean dry surface where   
					the Acclaim Camera Handpiece or USB Umbilical can be located for   
					convenient storage.   
					11   
				INFECTION CONTROL SHEATH   
					The Acclaim System should be used with an infection control sheath   
					covering the handpiece. Make sure to use a new disposable infection   
					control sheath for each patient.   
					The infection control sheath must be used for only one   
					patient and disposed of properly in accordance with   
					2 
					local code.   
					NOTE:   
					For optimum image clarity, the optically clear section of the sheath must be   
					aligned with the camera lens by facing the camera/light source section of the   
					handpiece down toward the paper layer.   
					Disposable Sheath Installation - Install a new infection control sheath   
					on the Camera Handpiece for each patient as follows:   
					1. Remove the Camera Handpiece from the holder.   
					2. Insert the Camera Handpiece tip between the second and third layers   
					(between the outer paper and plastic layers) with the camera/light facing   
					towards the paper layer. See A.   
					3. Push the Camera Handpiece completely in until the tip is fully inserted into   
					the narrow tip of the sheath. See B.   
					4. Gently squeeze the illuminated tip of the Camera Handpiece between the   
					thumb and index finger to ensure that the optically clear area of the sheath   
					is flat against the lens tip. See C.   
					5. Peel away and discard the top plastic layer and the bottom paper layer.   
					See D.   
					12   
				SYSTEM OPERATION   
					Verify that the video capture software is running and correctly configured.   
					The Acclaim System is operated connected directly to a computer system running   
					various PC USB streaming video capture software applications such as VISIX.   
					The camera provides the image/video source while the computer and associated   
					software are used to display and save the resultant images. Perform the following   
					procedures to operate the Acclaim System when correctly connected to a   
					computer.   
					1. Remove the Camera Handpiece from the handpiece holder and observe   
					that the computer display shows the high-resolution live video images   
					taken by the camera.   
					2. Place the camera lens window over area of interest and view image on   
					display.   
					3. Press the appropriate keypad button on the Camera Handpiece to freeze   
					(ie. capture) the displayed image on the computer monitor screen. Press   
					the keypad button again to unfreeze the displayed image. The keypad   
					button used depends on the video capture software installed.   
					4. Press the appropriate keypad button on the Camera Handpiece to save the   
					captured image to the computer hard drive and then to return to a live   
					image display. The keypad button used depends on the video capture   
					software installed.   
					5. Repeat steps 2 through 4 as necessary.   
					6. When imaging an X-ray film on a light box, deactivate the LED light   
					source by depressing both Camera Handpiece buttons simultaneously   
					for approximately 3 seconds. Perform steps 2 through 4 to freeze and   
					save the X-ray film image as desired.   
					7. Return the Camera Handpiece to the holder when done. Verify that the LED   
					light source and camera turns OFF.   
					13   
				CAMERA PORTABILITY   
					Do not twist or turn the Handpiece Cable connector. The connector is keyed and   
					mates straight on with Camera Handpiece connector.   
					Whether detaching just the Camera Handpiece from the USB Umbilical and   
					using with additional Acclaim USB Umbilicals installed on other computers or   
					bringing the complete system (handpiece and umbilical), the Acclaim System is   
					easily shared among patient operatories.   
					Refer to the corresponding illustrations and perform the following when trans-   
					porting only the Camera Handpiece.   
					1. Retract collar of quick disconnect connector and simultaneously pull   
					straight from the Handpiece connector.   
					2. Release connector quick disconnect collar.   
					3. Store the USB Umbilical by placing cable slide holder into the Handpiece   
					Holder.   
					4. Transport Handpiece to next operatory.   
					5. Connect Handpiece at new location by aligning the connector key with the   
					keyway of the mating USB Umbilical connector.   
					6. Insert straight into Handpiece connector until it securely snaps into place.   
					When transporting the complete Acclaim System (handpiece and umbilical)   
					among patient operatories, simply disconnect the the USB connector end of the   
					USB Umbilical, transport the system and reconnect to the new computer. Make   
					sure that the computer in the new operatory is using compliant software.   
					Connector Key   
					Camera   
					Handpiece   
					Quick Disconnect   
					Collar   
					Camera Handpiece   
					Detaching Camera Handpiece   
					Connecting Camera Handpiece   
					Quick Disconnect   
					Connector End   
					Handpiece Holder   
					Cable Slide Holder   
					Control Umbilical   
					Stored USB Umbilical   
					14   
				FINAL SYSTEM CHECK   
					USB Video Diagnostic - If live video is not displayed on the PC monitor of   
					the Acclaim System when the streaming video capture software application is   
					running, there could be a problem with the settings in the software application   
					or with the camera system.   
					Perform the USB Video Diagnostic procedure to check the following:   
					K The camera and the USB 2.0 interface control module of the USB   
					Umbilical are working correctly.   
					K The USB Umbilical is correctly connected between the camera and the   
					computer   
					K The camera USB driver files are installed correctly on the PC.   
					Conduct the USB Video Diagnostic by performing procedure the following steps.   
					1. Go to the Start button and select Programs.   
					2. Select the Acclaim program option and click on AMCAP and observe that   
					the AMCAP screen opens.   
					3. On the AMCAP screen, click DEVICES on the menu bar along the top of the   
					RA is selected from   
					screen and make sure that ACCLAIM USB ONLY CAMER   
					the drop down list.   
					4. Click OPTIONS on the menu bar along the top of the AMCAP screen and   
					make sure that PREVIEW is selected from the drop down list.   
					5. Depending on the outcome of the USB Video Diagnostic, perform one of   
					the following:   
					a. If a live image is correctly displayed, exit from AMCAP application and   
					make sure that the streaming video capture software application is   
					configured correctly.   
					b. If a live image is not displayed, exit from AMCAP application and   
					check the camera, USB Umbilical and USB driver file installation.   
					c. If a live image is displayed but the image colors are not correct, reset   
					the driver's video settings by performing the procedures of step 6.   
					6. Reset the driver's video settings by performing the following:   
					OPTIONS   
					a. On the AMCAP screen, click   
					on the menu bar along the   
					top of the screen and select VIDEO CAPTURE FILTER from the drop   
					down list.   
					b. On the Properties screen select the VIDEO PROC AMP tab and then   
					click the DEFAULT button. The image colors should now be correct.   
					OK   
					Click   
					to close the Properties screen and exit from AMCAP   
					application.   
					15   
				MAINTENANCE   
					INSPECTION AND CLEANING   
					Perform the following inspection and cleaning procedures periodically as a   
					preventive maintenance measure to keep the Acclaim System in optimal   
					condition resulting in trouble-free operation producing crisp, clear images.   
					Do not attempt any internal service of Acclaim System components. Contact your   
					local authorized air techniques dealer for service. Failure to heed this warning may   
					result in equipment damage and voiding the warranty.   
					Inspection - Routinely inspect each component of the Acclaim System for pos-   
					sible defects as follows:   
					1. Camera Handpiece -   
					a. Check overall handpiece for chips, cracks or other irregularities.   
					b. Check the lens window for debris or spots.   
					c. Check the connector socket for damage.   
					2. Cables and Connectors -   
					a. Check cables for damaged or deteriorated insulation kinking or   
					twisting.   
					b. Check connectors for loose, bent or missing pins.   
					c. Check that the quick-disconnect plug end snaps close to snugly   
					secure the Camera Handpiece connector.   
					Do not spray cleaning liquids or disinfectants directly on the camera hand-   
					piece. Use care not to allow liquids to run into internal circuitry.   
					Do not wipe the surfaces using benzine, thinner, etc. as this may degrade   
					the finish.   
					Do not autoclave the Camera Handpiece.   
					CAUTION: Unplug the Acclaim System components before performing cleaning.   
					The infection control sheath must be used for only one   
					patient and disposed of properly in accordance with   
					2 
					local code.   
					Cleaning - Clean each component of the Acclaim System as necessary by   
					performing the following procedures.   
					1. Camera Handpiece - Following every patient use, remove the infection   
					control sheath from the Camera Handpiece and dispose in accordance   
					with local regulations. The Camera Handpiece can be wiped clean and   
					disinfected with any non-corrosive surface disinfectant such as Birex® se.   
					2. Camera Window Lens - Remove debris or spots from lens window by   
					cleaning with alcohol and cotton swabs.   
					16   
				SPECIFICATIONS   
					Power Consumption:   
					USB powered device using less than 500   
					mA. No external power supply is   
					required.   
					Video Outputs:   
					Sensor:   
					High Speed USB 2.0 Video   
					¼ Inch CCD   
					Format:   
					NTSC   
					Pixels:   
					768 H X 494 V   
					470 TV lines   
					Resolution:   
					Signal to Noise Ratio:   
					Exposure Control:   
					Illumination:   
					> 50 dB   
					Automatic   
					Ultra-bright white LED lamps   
					Normal, not mirrored   
					50 Degrees horizontal   
					10º to 40º C   
					Image:   
					Viewing Angle:   
					Operating Temperature:   
					Storage Temperature:   
					Humidity:   
					0º to 70º C   
					10 to 90% non-condensing   
					Classifications:   
					Portable, Continuous Operation, Class   
					2, Type B   
					Protection for Ingress   
					of Water:   
					Ordinary   
					Flammable Atmosphere:   
					Cannot use in the vicinity of flammable   
					anesthetic mixtures of air, oxygen or   
					nitrous oxide.   
					Minimum PC Requirements for USB Video:   
					CPU Speed:   
					Pentium-4, 2 GHz or higher   
					Operating System:   
					Windows 2000 Service Pack 4 or   
					Windows XP Service Pack 1 with   
					Microsoft knowledge base KB822603   
					update   
					DirectX 9 compliant streaming video   
					software application installed   
					USB Port:   
					Must be USB 2.0 high speed, high power   
					port   
					17   
				PHYSICAL CHARACTERISTICS   
					Dimensions   
					Length   
					Width   
					Height   
					Weight   
					Handpiece A5520:   
					8.3 inches 1.0 inches 0.9 inches   
					(21.08 cm) (2.54 cm) (2.29 cm)   
					2.1 oz.   
					(59 g)   
					USB Umbilical A5550:   
					13.5 feet   
					(4.11 m)   
					7.8 ounces   
					(221.12 g)   
					USB 2.0 Interface   
					Control Module   
					5.9 inches 1.9 inches 0.9 inches   
					(15.0 cm)   
					(4.8 cm)   
					(2.3 cm)   
					USB 2.0 Cable   
					4 feet   
					(1.22 m)   
					Control Umbilical   
					9 feet   
					(2.74 m)   
					ACCESSORIES   
					The following lists the ordering number and description for accessory compo-   
					nents available to maintain and expand the Acclaim USB Only Camera System   
					to meet your professional needs. Contact your Air Techniques Dealer for   
					information.   
					Order   
					Number   
					Description   
					A5500   
					A5520   
					A5550   
					A5145   
					Complete Acclaim System consisting of the following:   
					Acclaim Camera Handpiece Assembly   
					USB Umbilical   
					Camera Handpiece Holder with Double-Sided Adhesive   
					Fastener   
					Replacement Disposable Infection Control Sheaths for Camera Handpiece   
					A5110   
					A5100   
					Box of 100   
					Box of 500   
					74500   
					VISIX Imaging Software, 5 Licenses, see page 19.   
					18   
				VISIX IMAGING SOFTWARE   
					Consider VISIX, our new comprehensive digital imaging software application,   
					providing seamless integration with our digital imaging suite; the Accent CCD   
					Intraoral Sensor, ScanX PSP Systems and Acclaim Intraoral Cameras.   
					Key Features.   
					K Easy to learn.   
					K Simple to use.   
					K Acquire, mount, view and store images with just a few mouse clicks.   
					K Customize images to personal preferences with our simple Set-Up 1-2-3   
					tool.   
					K Exposure - Our Stop Light Exposure System is a unique indicator to ensure   
					optimum data capture. It helps you acquire great images by monitoring   
					X-ray exposure.   
					K Viewing - VISIX provides automatic image mounting that is completely   
					customizable.   
					K Flexibility - VISIX includes a built-in bridging solution to over 35 Practice   
					Management Software titles.   
					VISIX is the superb software complement for Acclaim. Contact your authorized   
					dealer for further information.   
					19   
				Air Techniques and ALLPRO Imaging are leading manufacturers of   
					fine dental, medical and veterinary equipment from air and vacuum   
					systems and X-ray film processors, to an impressive line of new   
					products incorporating the most recent technological advances.   
					These new products, vital components of the innovative professional   
					practice, include intraoral cameras, digital imaging systems, which   
					utilizes phosphor plate technology and, most recently, an intraoral   
					digital X-ray system using sensor technology.   
					Air Techniques and ALLPRO Imaging have been manufacturing   
					quality products for the dental, medical and veterinary professional   
					since 1962.   
					Air Techniques and ALLPRO Imaging products are distributed only   
					
					
					K 
					K 
					K 
					K 
					K 
					K 
					K 
					K 
					K 
					K 
					K 
					K 
					AccentJ Intraoral Digital X-ray Image System   
					Acclaim® USB Only Intraoral Digital Video Camera System   
					Acclaim® Intraoral Digital Video Camera System   
					AirStar®   
					A/T 2000® XR   
					GuardianJ Amalgam Collector   
					1-800-AIR-TECH   
					Peri-Pro®   
					(1-800-247-8324)   
					
					Provecta 70J   
					Rinsendo Root Canal Disinfection System   
					ScanX®   
					STSJ   
					VacStarJ   
					K 
					K 
					K 
					K 
					K 
					K 
					K 
					K 
					K 
					K 
					K 
					K 
					100 Plus   
					2010   
					Medscope   
					Provecta V   
					ScanX® 12   
					ScanX® DVM   
					ScanX® 12DVM   
					ScanX® NDT   
					ScanX® 12 Portable   
					1-800-AIR-TECH   
					ScanX® 14 Portable   
					(1-800-247-8324)   
					ScanX® NDT Portable   
					
					ScanX® 14 In-Counter   
					ALLPRO Imaging is a Division of Air Techniques, Inc   
					© Copyright 2006, P/N A5551 Rev. C   
				 |