| 	
		 PLEASE READ BEFORE USE AND SAVE   
					12,000 BTU Dual Hose Portable   
					Air Conditioner   
					Heater & Dehumidifier   
					Innovative Products For Living   
					INSTRUCTION MANUAL   
					MODEL PACRWC   
					WindChaser Products, Inc.   
					4130 Del Rey Avenue, Marina del Rey, CA 90292   
					Phone: 310-827-8615 Fax: 310-827-8566   
					Toll Free: 1-800-405-2943   
					©2006 WindChaser Products, Inc.   
					
				PRODUCT LIMITED WARRANTY   
					BEFORE INITIAL USE   
					This Warranty applies to new Product only and excludes optional accessories and attachments. Extended   
					Compressor Warranty applies only to Product with manufacturing dates beginning January 1, 1998.   
					Read this Entire Instruction Manual Before Use.   
					During the first year from date of original purchase this WINDCHASER Product is warranted to be free from   
					defects in materials or workmanship under normal use, service and maintenance. During the 2nd through 5th   
					years from the date of original purchase, ICP warrants the compressor (part only) against defects in   
					material or workmanship under normal use, service and maintenance.   
					WHAT IS COVERED: Product’s components as originally affixed by the manufacturer that are   
					defective in materials or workmanship under normal use, service and maintenance.   
					Attach your purchase receipt here   
					WHAT IS NOT COVERED BY THIS WARRANTY: This Warranty does not extend to or cover:   
					PLEASE KEEP YOUR RECEIPT.   
					1.   
					Any defect due to the negligence of others; failure to install, operate or maintain unit or   
					accessories and attachments in accordance with installation instructions (operating,   
					installation and maintenance manual and instructions are furnished with each new unit);   
					unreasonable use; accidents; alteration, use of unauthorized or non-standardized   
					WINDCHASER parts, accessories and attachments; acts of God; theft; vandalism; blown fuses;   
					electrical malfunction. (i.e., resulting from power surges, shorted or overloaded circuits,   
					outlets or electrical utility power quality, etc.), incorrect installation; use of any power   
					source other than that specified on the Product’s specification label; or repair by anyone   
					other than a service facility authorized by an ICP representative   
					Diagnostic, troubleshooting and travel costs.   
					YOUR RECEIPT IS YOUR PROOF OF   
					PURCHASE AND IS NECESSARY FOR   
					WARRANTY SERVICE   
					2.   
					3.   
					4.   
					5.   
					Operation and usage orientation costs.   
					Performance or operation certification and testing costs.   
					Normal wear and tear of parts including but not limited to hoses, cables, accessories and   
					attachments.   
					For your reference:   
					6.   
					7.   
					8.   
					Shipping, handling, packaging and delivery costs of the product, parts or accessories   
					Shipping, handling, and freight damages.   
					Diagnosing, repairing, removing, installing, shipping, servicing and/or handling costs of   
					either defective parts or replacement parts as relating to Extended 4 Year Compressor   
					Warranty.   
					Serial No.   
					WHO IS COVERED: The original purchaser from the retailer/dealer.   
					Date of Purchase   
					WHAT WE WILL DO: During the first year ICP will either repair or replace, at its option, all   
					defective Product components free of charge that are covered by this Limited Warranty. During the   
					second through fifth years ICP at its option, will provide a new or refurbished compressor (part only)   
					free of charge.   
					Name and Address of Dealer   
					WHAT YOU MUST DO FOR WARRANTY SERVICE: Contact your original point of purchase to   
					determine warranty process.   
					12   
					1 
				LEARN INTELLIGENT AIR   
					CONDITIONING   
					This Portable Air Conditioner is electronically controlled,   
					which allows precise programming to adjust the room tem-   
					perature. This unit is a small appliance that adjusts the   
					temperature and humidity in a room. It’s flexibility makes it   
					easy to use in different applications and in various rooms.   
					This unit is designed for use in a home, office and comput-   
					er type room. This air conditioner allows you to control the   
					4 factors that determine optimal comfort in a room.   
					SAFETY INSTRUCTIONS   
					TROUBLESHOOTING GUIDE   
					READ ALL INSTRUCTIONS BEFORE USING THE AIR   
					CONDITIONER   
					When using electrical appliances, basic precautions should   
					always be followed to reduce the risk of fire, electric shock,   
					and injury to persons, including the following:   
					1) Do not damage the power cord.   
					When the air conditioner does not work, it is sometimes a minor problem which the user can handle.   
					Before calling customer service, please check the following points to see if they solve your problem.   
					
					Problem   
					Probable Causes   
					Solutions   
					2) Never lay the unit down while it is off or working.   
					3) Always keep it in an upright position to avoid any   
					damage to the cooling system.   
					The air conditioner / dehumidifier   
					doesn’t work.   
					1) Check LCDI plug to be certain it is in an 1) Press the test button, then firmly press   
					engaged position   
					the reset button.   
					4) Operate this unit in an ambient temperature of 90oF   
					or lower.   
					2) Plug not properly inserted into wall   
					outlet.   
					2) Plug the appliance in properly.   
					• Humidity Rate: the humidity in a room also causes   
					a sensation of stifling heat in the summer. Your air   
					conditioner not only cools down the temperature,   
					but dehumidifies the air as well.   
					• Heater: The air conditioner will function as a heater,   
					releasing warm air into the room without use of hose   
					extensions.   
					• Temperature: the main function of an air conditioner   
					is to draw hot air out of the room.   
					• Airflow: The air conditioner regulates the airflow,   
					allowing the flow to be directed and ensuring   
					optimal air circulation   
					• The unit will not instantaneously cool down the   
					room once it is turned on. It will take the unit some   
					time to gradually cool down the room.   
					• Ion Generator: Cleans and freshens the air. Produces   
					Negative Ions For Clean and A Healthy Environment   
					5) Be sure that the air inlets and outlets are not blocked   
					or covered up.   
					6) Never place anything on top of the unit and do not   
					cover it with any kind of cloth while it is plugged in   
					or in-use.   
					7) Your air conditioner has been designed to be used only   
					in a house, office and similar conditions and it should   
					not be used for any other purpose.   
					8) Never connect the unit to a defective outlet.   
					9) This unit needs at least 12Amps of electricity to start it’s   
					compressor. Plug the unit into a properly grounded   
					dedicated 15Amp or greater circuit. Check your breaker   
					box to determine which circuit the outlet is on.   
					10) Make sure that the unit is correctly connected before   
					turning on the unit’s power.   
					3) Insufficient amount of amperage to   
					start unit.   
					3) Check circuit breaker box for   
					15-20amp circuit availability.   
					4) Water tank is full / alarm light   
					illuminated.   
					4) Drain Unit.   
					The air conditioner cuts off.   
					1) Exhaust hose too long, run   
					incorrectly or kinked.   
					1) Exhaust hose can only be   
					extended using max. 5’ of 4”   
					PVC pipe or flex ducting for a total   
					exhaust length of 10’.   
					2) Unit too close to wall   
					or object.   
					2) Unit should be at least 1 ½’   
					away from walls and objects   
					3) Ceiling or basement does   
					not have ample ventilation.   
					3) Unit will overheat if the exhaust   
					cannot fully vent.   
					11) Never unplug the air conditioner while it is working.   
					This could damage the electronic circuits.   
					12) To avoid tripping the circuit, DO NOT USE AN   
					EXTENSION CORD FOR THIS UNIT.   
					13) To turn on your unit, always use the switch on the   
					control panel.   
					4) The “timer off” function   
					has been activated.   
					4) Push the power button to turn unit on.   
					*Note: Avoid being directly in front of the cold airflow and do   
					not direct it onto people.   
					5) Room temperature is not between   
					61o-90oF.   
					5) Turn unit back on when room   
					temperature is between 61o-90oF.   
					14) Do not bend or crush the warm air exhaust hose.   
					15) It is dangerous to modify or to change the   
					characteristics of the unit.   
					16) Prevent children from climbing on the unit.   
					17) Do not place the air conditioner near curtains   
					(minimum distance 1.5 ft.).   
					18) Do not place the power cord under a carpet.   
					19) Never install the unit in direct sunshine or in the rain.   
					20) Keep the area around the warm air outlet sufficiently   
					clean and make sure that it is not congested.   
					21) For any repairs, refer directly to our customer service   
					department. Repairs carried out by unqualified people   
					may cause damage or may even be dangerous   
					and void the warranty.   
					IMPORTANT INSTRUCTIONS   
					The WATER FULL LED indicator   
					light flashes.   
					The condensate tank is full and   
					the unit cannot drain. This safety feature   
					turns off the unit to protect the unit and   
					prevent the condensate tank from   
					overflowing.   
					Drain unit from the drain plug at the back   
					of the unit.   
					Do not install and use your air conditioner before   
					completely reading these instructions. This will help you   
					optimize the operation of your air conditioner.   
					The following advice and instructions should be   
					followed closely:   
					The LED display shows the unit is set, but   
					the unit is not running.   
					The unit’s “timer on” feature is   
					activated.   
					1) This is normal.   
					BEFORE OPERATING THE UNIT, BE SURE THE   
					DRAIN PIPE IS CAPPED WITH THE DRAIN PLUG.   
					2) Push the Power button to turn the unit   
					on and deactivate the “timer on” feature.   
					1. Your unit must always be used in an upright   
					position because it contains a cooling agent.   
					E1: Error code   
					E2: Error code   
					Room temperature sensor is damaged   
					Room coil sensor is damaged   
					Need to change the temperature sensor   
					(contact WindChaser Products customer   
					service)   
					2. After unpacking, place the unit upright to allow the   
					cooling agent to stabilize, and wait 3 hours before   
					use.   
					Any damage resulting from failure to comply with these   
					instructions is excluded from the warranty.   
					Need to change the room coil sensor   
					(contact WindChaser Products customer   
					service)   
					SAVE THESE INSTRUCTIONS   
					3. When used for the first time, and every time it is   
					turned on, it takes your unit up to 3 minutes to be   
					operational.   
					Failure to comply with these instructions may damage the   
					unit and would invalidate the WINDCHASER guarantee.   
					E3: Error code   
					E4: Error code   
					Anti-freezing protection (compressor)   
					Contact WindChaser Products customer   
					service   
					System protection is abnormal (R22 has   
					leaked)   
					Contact WindChaser Products customer   
					service   
					2 
					11   
				unit, your unit must always be used with its air filter.   
					Using the unit in wine cellars or in any room with   
					a temperature under 61oF is not recommended.   
					a path of least resistance for electric current to   
					reduce the risk of electric shock. This product is   
					equipped with a cord having an equipment   
					grounding conductor and a three prong   
					grounding plug. The plug must be plugged   
					into an appropriate three prong outlet that is   
					properly installed and grounded in accordance   
					with all local codes and ordinances. Do not use   
					plug adapters or extension cords with this unit.   
					PROTECTION   
					• The build up of dust reduces the efficiency of the air   
					conditioner. Therefore, the air filter must be cleaned   
					every 100 hours of use, and every two weeks if the   
					unit operates in a dusty atmosphere.   
					• If the filters are obstructed, the air conditioner will be   
					less efficient.   
					• To remove the air filter, place fingers in the notch just   
					under the top of the air filter handle and pull up.   
					• Clean the filter with a vacuum cleaner. If the filter is very   
					dirty, you can wash it in warm water (never use hot or   
					soapy water). Make sure that the air filter is completely   
					dry before putting it back in the unit.   
					a) Operating Condition - The protective device will   
					be tripped, and the unit will shut off under these two   
					conditions:   
					ENERGY SAVING TIPS   
					• Cooling: (1) Outdoor air temperature is over   
					109oF (*43oC). (2) Room temperature is below   
					61oF (16oC).   
					• Blocking of the filter reduces the efficiency of the air   
					and increases its power consumption by up to 6%.   
					• Avoid opening doors frequently.   
					• Each person present in a room provides between   
					100 Watts and 150 Watts of heat. Consequently, the   
					more people there are in a room, the less effective   
					the unit will be in cooling.   
					• To ensure the optimal efficiency of the unit, we   
					advise you to keep doors and windows closed, and   
					to take into account the surface of the walls and   
					windows exposed to the sun. In this case, in order   
					to optimize the functioning of your air conditioner,   
					we recommend partially closing window coverings.   
					• Heating: (1) Outdoor air temperature is below   
					23oF (-5oC).   
					SAFETY POWER SUPPLY CORD   
					• Dry: Room temperature is below 61oF (16oC).   
					• Do not bend the filter.   
					This unit is provided with a Leakage Current Detection and   
					Interruption circuit (LCDI) built into the plug of the power   
					supply cord. This device provides protection to reduce the   
					risk of fire due to arcing faults in the power-supply cord.   
					Perodically before using the Room Air Conditioner, follow   
					the "Plug Testing Instructions" given below to ensure that   
					the LCDI circuit is functioning properly.   
					If the air conditioner runs in COOLING or DRY mode with   
					door or window opened for a long time when relative   
					humidity is above 80% condensation may drip down from   
					the outlet.   
					LONG TERM STORAGE   
					At the end of the season, or when you do not plan to use   
					the unit for an extended period of time, we recommend   
					that you take the following steps:   
					b) Features of Protector   
					• Restarting the unit at once after operation stops or if   
					changing mode during operation, you need to wait   
					3 minutes.   
					PLUG TESTING INSTRUCTIONS: TO BE DONE WHILE   
					PLUG IS IN OUTLET.   
					• Connect to power supply and turn on the unit at once,   
					it may start 20 seconds later.   
					SPECIFICATIONS   
					1. PRESS TEST BUTTON. UNIT SHOULD TRIP.   
					2. FIRMLY PRESS RESET BUTTON FOR USE.   
					• If the plug is taken out, when you restart the appliance,   
					it will return to the original mode, TIMER ON and   
					TIMER OFF must be set again.   
					Cooling Capacity:   
					Heating Capacity:   
					Power Input: Cooling   
					Heating   
					12,000 BTU/Hour   
					4100 BTU/Hour DO NOT USE IF ABOVE TEST FAILS.   
					1450Watt/14.5Amps   
					CONDENSATION ELIMINATION SYSTEM   
					While air conditioning mode, the unit automatically dehu-   
					midifies the air in the room. The water from dehumidifica-   
					tion is stored in a collecting tank and then is immediately   
					“evaporated” and evacuated via the exhaust port.   
					However, when it is extremely humid, the water in the col-   
					lecting tank may fill up. In this case, the Water Full   
					Indicator Light turns on and the air conditioner switches   
					itself off.   
					1350 Watt/12Amps The conductors inside this power supply cord are sur-   
					Energy Efficiency Ratio:   
					Coolant:   
					8.2   
					rounded by shields which monitor the leakage current.   
					R-22/550g These shields are not grounded. Periodically examine the   
					Moisture Removal:   
					2.5 Pints / Hour   
					(60 Pints / Day)   
					cord for any damage. If the shield gets exposed, immedi-   
					ately unplug the power supply cord and do not use the   
					Airflow Volume:   
					Noise Level:   
					Compressor Type:   
					177 CFM (Cubic Feet / Minute) unit. Do not repair a damaged cord. Replace the damaged   
					46 db cord only with a new replacement power supply cord   
					Rotary obtained from the manufacturer.   
					Operating Temperature Range:   
					It is then necessary to drain the water through the conden-   
					sate drain hose. For draining instructions, please refer to   
					the “Long Term Storage” instructions under the “Cleaning   
					the Unit” instructions.   
					Cooling: 61o - 108oF (16o - 42oC)   
					In the event the LCDI Plug of the power supply cord trips   
					by itself, then first examine the cord for any damage. If   
					there is no damage to the cord then press the RESET   
					Button. If the LCDI Plug trips again, then immediately   
					unplug the power supply cord. Replace the damaged   
					cord with a new replacement power supply cord.   
					Heating: 23o - 90oF (-5o - 32oC)   
					115V/60Hz   
					Voltage/Frequency:   
					Ionization Capacity:   
					100,000 PCS/CM3   
					Product Dimension (WxHxD):   
					17.7” (W) x 32.28” (H) x 18.3” (D)   
					Drain Hose   
					CLEANING AND STORAGE   
					45cm(W) x 82cm(H) x 46.5cm(D)   
					Net Weight: 83lbs. / 37.6kgs.   
					Product Net Weight:   
					To obtain a new replacement power supply cord contact   
					WindChaser Products Customer Service at:   
					(800) 405-2943 or e-mail at:   
					Before cleaning the unit, turn it off and unplug it from the   
					outlet. For safety reasons, never wash the air conditioner   
					by hosing it down or wiping it with a dripping wet sponge   
					or cloth.   
					Drain excess water from the drainpan from the Drain Hose   
					• Run the unit for 3 to 4 hours in fan mode.   
					This will thoroughly dry the inside of the unit.   
					• Disconnect the unit and wrap the power cord   
					and plug around the cord hooks in the back.   
					• Take out the batteries from the remote.   
					• Remove the air hoses and cover the air intake   
					and air outtake holes with the included covers.   
					• Clean the unit and air filter and store it in it’s   
					original packaging, protecting it from dust.   
					• Store the unit in an upright position. Keep it in   
					a cool, dry place and away from sunshine.   
					1. All wiring must comply with local and national   
					electrical codes and be installed by a qualified   
					electrician. If you have any questions regarding   
					the following instructions, contact a qualified   
					electrician.   
					
					Exterior surfaces of the unit   
					• Clean the air conditioner by using a damp sponge, and   
					dry it with a clean, soft cloth.   
					• Never use alcohol or any product containing solvents.   
					• Never sprinkle water onto the unit. This may cause an   
					electric shock.   
					Do not use The TEST and RESET Buttons as an on / off   
					switch. They are only meant to be used to periodically   
					check the LCDI plug.   
					2. Check available power supply and resolve any   
					wiring problems before installation and operation   
					of this unit.   
					Air filter   
					3. This product must be grounded. If it should   
					malfunction or breakdown, grounding provides   
					The air filter located on the back of the unit, collects dust   
					contained in the air. To keep the dust from clogging the   
					10   
					3 
				9. ION BUTTON   
					Remote control real time clock instructions   
					-Open the battery cover of the remote control and press   
					the Clock Set button with a pencil or pen.   
					-Press the HR. button and MIN button and adjust the cor-   
					rect time.   
					-Press the Clock Set button again and close the battery   
					cover.   
					-The display will show the correct time   
					Press the Ion Button until ‘   
					display, press again to stop.   
					10. TIME ON   
					’ appears on the Main LED   
					PARTS   
					To program the timer, press Timer On button until the   
					Main LED display shows a flashing ‘ ’.   
					11. TIME OFF   
					Press Timer Off button and the Main LED display will   
					show a flashing ‘ ’.   
					12. HR   
					Press to set the desired hour setting.   
					13. MIN.   
					1 
					Front View   
					2 
					1. Control Panel with LED Display   
					2. Adjustable Dial: Thermostat and Timer   
					3. Adjustable Vertical/Horizontal Louvers   
					4. LED Display   
					Clock Time settings: HR and MIN   
					To set the hours, press HR button once, the time will add 1   
					hour, continue to press this button, the clock will add by   
					1hour until extended to 11 hours, then will change to PM   
					or AM and return to 0 (12:00).   
					Press to set the desired minute setting.   
					3 
					5. Handle   
					6. Remote Control   
					5 
					NOTE: ALL SETTINGS CAN BE VIEWED ON THE REMOTE   
					DISPLAY   
					To set the minutes, press MIN button once, the clock will   
					SETTING THE UNIT TO TURN ON AND SHUT OFF add 1 minute, continue to press this button and the clock   
					4 
					will add by 1 minute until extended to 59 minutes, then   
					return to 00.   
					AT A DESIRED TIME.   
					6 
					Press the TIME ON button once, to set the start time of   
					the unit. Press the TIME ON button again to cancel this   
					setting.   
					Reset button   
					Clock set button   
					Press the TIME OFF button once, to set the end time of   
					the unit. Press the TIME OFF button again to cancel this   
					setting.   
					To set specific TIME ON   
					1. Press the TIME ON button once   
					2. Select the desired hour and minutes you want the unit   
					to turn on again.   
					-To set the hours, press the HR button once, advancing   
					the timer 1 hour, continue to press this button, the clock   
					will add by 1hour until extended to 11 hours, then will   
					change to PM or AM and return to 0 (12:00). When the   
					timer advances to 11, the next press will return the timer   
					to either 12:00 am or pm.   
					-To set the minutes, press MIN button once, the clock will   
					add by 10 minutes, continue to press this button. The   
					clock will add by 10 minutes until extended to 50   
					minutes and return to 0.   
					8 
					Rear View   
					7. Air Outlet Hose   
					8. Evaporator Air Intake   
					9. Air Intake Hose   
					10. Hose Connectors   
					11. Water Stopple and Drain   
					12. Power Cord   
					3. Once time is set do not press the TIME ON button.   
					Back of remote   
					To set specific TIME OFF   
					1. Press the TIME OFF button once   
					2. Select the desired hour and minutes you want the unit   
					to turn on again.   
					13. LCDI Plug   
					9 
					7 
					TO RESET ALL FUNCTIONS ON THE REMOTE   
					CONTROL PRESS THE RESET BUTTON WITH   
					A PENCIL OR PEN.   
					-To set the hours, press the HR button once, advancing   
					the timer 1 hour, continue to press this button, the clock   
					will add by 1hour until extended to 11 hours, then will   
					change to PM or AM and return to 0 (12:00). When the   
					timer advances to 11, the next press will return the timer   
					to either 12:00 am or pm.   
					10   
					-To set the minutes, press MIN button once, the clock will   
					add by 10 minutes, continue to press this button. The   
					clock will add by 10 minutes until extended to 50   
					minutes and return to 0.   
					12   
					11   
					3.Once time is set do not press the TIME OFF button.   
					4 
					9 
				OPERATION USING ADJUSTABLE DIAL SWITCH   
					NOTE:   
					1. Do not abuse the remote control.   
					2. Do not place the remote control in a location that is   
					exposed to direct sunlight or next to a heating unit or   
					other heat source.   
					3. Do not use rechargeable batteries because they   
					differ from standard dry cell batteries in shape,   
					dimension and performance.   
					EXHAUST KIT   
					INSTALLATION   
					To adjust desired temperature and program the timer.   
					Select the desired temperature by turning Adjustable Dial   
					Switch when using the unit in cooling or heating function.   
					o 
					o 
					o 
					The desired temperature range is from 61 F-88 F (16 C-   
					o 
					3 
					31 C). The LED flashes to display the desired   
					temperature during the setting, it displays the room   
					temperature after 5 seconds, .   
					4. Be sure to replace the batteries with two new   
					batteries of the same type.   
					Press Timer On/Off button, turn adjustable dial switch to   
					change the clock to the desired time for the unit being   
					turned on or off.   
					Horizontal   
					Vertical   
					Remote   
					Display   
					2 
					4 
					1 
					NOTE: Your window kit has been designed to fit most   
					standard vertical and horizontal window applications.   
					However, it may be necessary for you to improvise/modify   
					some aspects of the installation procedures for certain   
					types of windows. Please refer to measurements below:   
					ADJUSTABLE and   
					OSCILLATING LOUVERS   
					5 
					Automatic Oscillating   
					Louvers   
					Manual Horizontal   
					Louvers   
					Window slider kit   
					minimum: 28 /81 (72cm)   
					maximum:55 /38(140cm)   
					Window slider kit   
					minimum: 281/8(72cm)   
					maximum:553/8(140cm)   
					1) Select a suitable location, making sure you have easy   
					access to an electrical outlet.   
					REMOTE CONTROL   
					REMOTE CONTROL FUNCTIONS   
					1. ON/OFF-   
					PREPARATIONS   
					2) Remove the 2 hoses, 2 window exhaust adapters,   
					1 window panel kit.   
					Starts or Stops the Unit   
					2. WARM   
					Adjust to desired warm temperature.   
					3. COOL   
					Adjust to desired cool temperature.   
					4. MODE   
					A Side   
					3) To install the flexible exhaust hoses, insert the end of   
					the hose with the round connector into either the air   
					inlet or air outlet hole on the back of the unit. Turn the   
					hose clockwise to secure the hose into the hole. Do   
					this for both hoses.   
					Select the functions of the unit for: Fan Mode,   
					Air Conditioning Mode, Heating Mode,   
					Dehumidifying Mode and Auto Mode   
					5. TEMP./%   
					WINDOW INSTALLATION   
					1. Exhaust Ports   
					2. Air Outlet Hose (exhaust)   
					3. Air Intake Hose   
					4) Screw the window exhaust adapters on both hoses by   
					turning them clockwise.   
					To display temperature or humidity on both Main LED and   
					LED. Hold the button more than 3 seconds, to convert the   
					o 
					o 
					temperature display from Fahrenheit ( F) to Celsius ( C)   
					and vice versa. Press the button for less 3 seconds to view   
					the humidity.   
					5) Insert the air inlet window exhaust Adapter into the left   
					hole of the window panel kit. Then insert the air outlet   
					window exhaust Adapter in the right hole of the window   
					panel kit.   
					6. FAN   
					4. Window Exhaust and Intake Adapter (2)   
					5. Adjustable Window Panel   
					Air Inlet and Air Outlet Hose: Extends from 17”   
					(43cm) up to 5.9 ft (1.8m)   
					Select the fan speed desire: High, Medium and Low   
					The fan speed can be visually distinguished by the speed   
					of the digital air segments progressing out from the wind   
					mill fan image on the Main LED display.   
					1. Remove the cover from the back of the remote control.   
					2. Insert two AAA dry-cell batteries (batteries included)   
					3. Insert the power plug into an outlet.   
					4. Always point the remote control signal transmitter   
					toward the unit when operating.   
					5. Make sure that the signal path is not obstructed.   
					6. The maximum distance at which signals can be   
					received is 26.24 feet.   
					7. Remove the batteries if the unit is not going to be used   
					for an extended period of time.   
					NOTE: 1. Step 3 is required only when using cooling or   
					dehumidification modes. In cooling mode the two hoses or   
					the air outlet hose can be installed for the unit to operate.   
					2. While operating or installing, the hoses should not be   
					blocked by curtains or any other obstructions.   
					NOTE: WHEN PLACING THE WINDOW PANELS VERTICAL,   
					MAKE SURE THE AIR OUTLET HOSE IS SECURED TO THE   
					TOP OUTLET HOLE OF THE WINDOW PANEL.   
					7. SWING   
					To start swinging air louvers horizontally by press SWING   
					Button once. At the moment, appears on the Main LED   
					display. To stop, press SWING again. Vertical air flow   
					direction can be adjusted manually.   
					Window Kit: Extends from 28.375” (72cm) up to   
					55.625” (140cm)   
					8. SLEEP BUTTON   
					NOTE: Air outlet hose (exhaust) should be   
					mounted at A side   
					Press to select the function of the unit for Sleep Mode.   
					8 
					5 
				e) Select the fan speed by pressing the Fan button.   
					It is recommended to use the low fan speed.   
					NOTE: When the unit is running on heating mode, the   
					exhaust duct is inoperative and is not required.   
					6) The air conditioner can now be plugged into a 110-   
					120V/60Hz dedicated 15amp or greater circuit. You are   
					advised not to use an extension cord, however, if this is   
					unavoidable, the extension cord must be 14 gauge,   
					grounded at both ends and not more than 30 feet long.   
					Operating Functions   
					1) Cooling Operation   
					Control Panel   
					1) Power On/Off   
					Starts or Stops the Unit   
					2) Time On Button   
					a) Install the exhaust ducts properly.   
					b) Plug the Power Cord to the power outlet.   
					c) Turn on the unit by pressing the '   
					control panel.   
					d) Press Mode Button until ‘   
					LED display   
					To program the timer, press Timer On button until the Main   
					LED display shows a flashing ‘   
					dial switch to change the timer to the desired time for the   
					unit being turned on. Turn clockwise for increase in time   
					and counter cloclwise for decrease in time.   
					3) Time Off Button   
					'Button on the   
					’. Turn the adjustable   
					5) Auto Operation   
					a) Install the exhaust ducts properly   
					b) Plug the Power Cord into the power outlet.   
					If you need to extend your exhaust hose, it may be   
					extended 5 feet only. Using a 5 foot, 4 inch diameter PVC   
					pipe (available at your local hardware store), you must cut   
					the exhaust hose in half and duct tape the PVC pipe in   
					between the two cut pieces of the exhaust hose for a   
					maximum exhaust length of 10.9 feet. Flex ducting is also   
					recommended for extending the exhaust hose. DO NOT   
					USE ALUMINUM TYPE EXHAUST HOSE TO LENGTHEN   
					THE EXHAUST.   
					‘ appears on the Main   
					c) Turn on the unit by pressing the '   
					control panel.   
					' Button on the   
					e) Turn the adjustable dial switch until the desired room   
					temperature appears on the LED. The desired   
					Press Timer Off button and the Main LED display will   
					show a flashing ‘   
					change the clock to the desired time for the unit being   
					turned off. Turn clockwise for increase in time   
					and counter cloclwise for decrease in time.   
					d) Press the Mode Button until the ‘   
					Main LED display.   
					‘ appears on the   
					o 
					o 
					o 
					o 
					’. Turn the adjustable dial switch to   
					temperature range is from 61 F-88 F (16 C-31 C).   
					f) Select the fan speed by pressing the Fan Button.   
					NOTE: During hot days, the unit will cool off the room most   
					efficiently by setting the temperature at the lowest and the   
					fan speed at the highest. Reducing the length of the   
					exhaust duct and insulating the exhaust duct and keeping   
					direct sunlight to a minimum will also improve the cooling   
					efficiency.   
					e) Select the fan speed by using FAN button.   
					During AUTO mode, the unit operates in heating mode   
					The light will flash for 3 seconds to activate the timer you   
					have just programmed.   
					o 
					o 
					when the room temperature is below 68 F (20 C). It   
					operates in dehumidifying mode when the room   
					The compressor is an essential component of the   
					appliance for producing cold air. This appliance is fitted   
					with a thermal protection device which allows the   
					compressor to be started only after a time delay of up to   
					three minutes.   
					o 
					o 
					o 
					o 
					temperature is between 68 F (20 C) to 80 F(26.6 C). It   
					operates in cooling mode when the room temperature is   
					4) Ion Button   
					*WE RECOMMEND SETTING THE DESIRED ROOM   
					Press the Ion Button until ‘   
					display, press again to stop.   
					5) Temperature/ Humidity Button   
					’ appears on Main LED   
					o 
					o 
					o 
					o 
					above 80 F(26.6 C). You may use the timer with the   
					AUTO mode.   
					TEMPERATURE AT 70 F (21 C) OR ABOVE WHEN   
					FIRST ATTEMPTING TO COOL THE ROOM (ROOM   
					To display temperature or humidity on both the Main LED   
					and LED Display. Hold the button more than 3 seconds, to   
					o 
					o 
					TEMPERATURE IN EXCESS OF 85 F (29 C) ). ONCE   
					BEFORE OPERATING THE UNIT, BE SURE THE   
					DRAIN PIPE IS CAPPED WITH THE DRAIN PLUG.   
					6) Sleep Mode   
					a) The air conditioner is in operation   
					o 
					o 
					o 
					THE ROOM HAS COOLED BELOW 80 F (26 C), YOU   
					MAY ADJUST THE DESIRED ROOM TEMPERATURE   
					convert the temperature display from Fahrenheit ( F) to   
					o 
					Celsius ( C) and vice versa. To adjust the desired   
					b) Press SLEEP Button, the symbol ‘   
					the Main LED display.   
					‘ appears on   
					o 
					o 
					temperature setting turn the Adjustable Dial clockwise for   
					increase of temperature or counter clockwise for decrease   
					of temperature.   
					BELOW THE INITIAL 70 F (21 C) SETTING.   
					2) Dehumidifying Operation   
					OPERATING INSTRUCTIONS   
					AND FUNCTIONS   
					c) The fan motor will run on low speed   
					d) When in cooling mode, within the first two hours, the   
					temperature will be increased by one degree per hour.   
					a) Install the exhaust ducts properly   
					b) Plug the Power Cord into the power outlet.   
					c) Turn on the unit by pressing the '   
					control panel.   
					NOTE: This function can only be used while in cooling and   
					heating mode.   
					Press the button less than 3 seconds, to convert the display   
					from humidity to room temperature and vice versa.   
					' Button on the   
					o 
					Then the temperature will be kept at 2 F higher   
					SOFT TOUCH CONTROLS AND FUNCTIONS   
					than the originally set temperature for 6 hours. 6 hours   
					later, the temperature will return to the original setting.   
					e) When in heating mode, within the first 2 hours, the   
					temperature will decrease by one degree per hour.   
					Then the temperature will be kept at 2 degrees lower   
					than the original temperature for 6 hours. 6 hours later,   
					the temperature will return to its original setting.   
					g) When in dehumidifying mode, the temperature will not   
					be changed.   
					d) Press the Mode Button until the ‘   
					‘ appears on the   
					o 
					o 
					Main LED display.NOTE: The unit operates at low fan   
					speed during dehumidifying. The unit cools room slightly   
					during the dehumidification. Keep the windows and the   
					doors closed to aid in the effectiveness of the unit in   
					removing the moisture from the room. The unit will not   
					perform dehumidification function when the room   
					10)   
					The room temperature display range is from 32 F- 99 F   
					1)   
					o 
					o 
					(0 C- 37 C) .   
					11)   
					NOTE: The display temperature may differ from actual   
					temperature by ±4 F ( ±2 C )   
					o 
					o 
					6) Fan Speed Button   
					o 
					o 
					temperature is lower than 61 F(16 C).   
					3) Fan Operation   
					Select the fan speed desired: High, Medium or Low   
					The fan speed can be visually distinguished by the speed   
					of the digital air segments progressing out from the   
					windmill fan image on the Main LED display.   
					7) Mode Button   
					NOTE: When the room temperature is low and the indoor   
					humidity is high, the condensation formed by the air   
					conditioner in use may not be discharged quickly. The   
					2)   
					a) Plug the Power Cord into the power outlet.   
					b) Turn the unit on by pressing the '   
					control panel.   
					c) Press the Mode Button until ‘   
					Main LED display.   
					9)   
					3)   
					8)   
					4)   
					5)   
					7)   
					' Button on the   
					6)   
					symbol ‘   
					‘ appears on the Main LED display. In order   
					MAIN LED DISPLAY   
					Select the functions of the unit for: Fan Mode   
					Cooling Mode   
					, 
					‘ appears on the   
					for your unit to continue to run, you can pull out the "Drain   
					Port" which is located in the lower left bottom of the back   
					of the unit. The condensation will be discharged several   
					minutes after the water has been drained. Please use at   
					least a 3.17 pint pan to catch the dripping water. It is not   
					advisable to use the continuous drain method when the   
					, Heating Mode   
					, Dehumidifying   
					Mode   
					and Auto Mode .   
					d) Select the fan speed by pressing the Fan Button.   
					NOTE: When the unit is running on fan mode, the exhaust   
					duct is inoperative and is not required.   
					8) Sleep Button   
					Press to select the function of the unit for Sleep Mode.   
					9) Swing Button   
					To start swinging air louvers horizontally by press SWING   
					Button once. The symbol, '   
					LED display. To stop, press SWING again. Vertical air flow   
					direction can be adjusted manually.   
					10) Power Indicator Light   
					4) Heating Operation   
					o 
					o 
					' will appear on the Main   
					room temperature is higher than 88 (31 C).   
					a) Plug the Power Cord into the power outlet.   
					b) Turn on the unit by pressing the '   
					control panel.   
					' Button on the   
					c) Press the Mode Button until ‘   
					Main LED display.   
					d) Turn the adjustable dial switch until the desired room   
					‘ appears on the   
					Indicates the unit is on.   
					11) Run Indicator Light   
					ADJUSTABLE DIAL:   
					THERMOSTAT & TIMER   
					LED DISPLAY   
					Indicates the unit is in working mode   
					temperature appears on the LED. The desired   
					o 
					o 
					o 
					o 
					Decrease   
					Increase   
					temperature range is from 61 F-88 F (16 C-31 C).   
					6 
					7 
				 |