| INSTRUCTION MANUAL   PACR12 PORTABLE AIR CONDITIONER   PLEASE CAREFULLY READ AND KEEP THESE   INSTRUCTIONS FOR FUTURE REFERENCE   CONTENTS   SAFETY INSTRUCTIONS   2 2 LEARN INTELLIGENT AIR CONDITIONING   IMPORTANT INSTRUCTIONS   ENERGY SAVING TIPS   3 3 TECHNICAL SPECIFICATIONS   PARTS ILLSTRATION   3 4 CONTINUOUS DRAIN FEATURE   EXHAUST KIT INSTALLATION   OPERATING INSTRUCTIONS AND FUNCTIONS   CLEANING THE UNIT   5 6 8 10   11   12   TROUBLESHOOTING GUIDE   PRODUCT LIMITED WARRANTY   1 SAFETY INSTRUCTIONS    Do not damage the power cord.    To turn on your unit, always use the switch on the control   panel.    Never lay down the unit while it is working.    Always keep it in an upright position to avoid any   damage to the cooling system.    Do not bend or crush the warm air exhaust hose.    It is dangerous to modify or to change the characteristics   oftheunit.    Prevent children from climbing on the unit.    Do not place the air conditioner near curtains (minimum   distance1.5ft.).    Operate this unit in an ambient temperature of 90o   or lower.    Be sure that the air inlets and outlets are not blocked or   covered up.    Do not place the power cord under a carpet.    Never install the unit in direct sunshine or in the rain.    When used for the first time, and every time it is turned   on, it takes your unit up to 3 minutes to be operational.    Keep the area around the warm air outlet sufficiently   clean and make sure that it is not congested.    For any repairs, refer directly to our customer ser-   vice department. Repairs carried out by unqualified   people may cause damage or may even be dangerous   and void the warranty.    Never place anything on top of the unit and do not cover   it with any kind of cloth while it is plugged in or in-use.    Your air conditioner has been designed to be used   only in a house, office and similar conditions and it   should not be used for any other purpose.    Never connect the unit to a defective socket.    This unit needs at least 12Amps of electricity to start   it’s compressor. Plug the unit into a properly grounded   dedicated 15Amp socket.   Check your breaker box to determine which circuit the   socket is on.    Make sure that the unit is correctly connected before   turningontheunit’spower.    Never unplug the air conditioner while it is working. This   could damage the electronic circuits.    To avoid tripping the circuit, DO NOT USE AN   EXTENSION CORD FOR THIS UNIT.   Any damage resulting from failure to comply   with these instructions is excluded from the   warranty.   LEARN INTELLIGENT AIR-CONDITIONING   This Portable Air Conditioner is electronically controlled, which allows precise programming   to adjust the room temperature. This unit is a small appliance that adjusts the temperature   and humidity in a room. It’s flexibility makes it easy to use in different applications and in   various rooms. This unit is designed for use in a home, office and computer type room.   This air conditioner allows you to control the 4 factors that determine optimal comfort in   a room.    Humidity Rate: the humidity in a room also   causes a sensation of stifling heat in the   summer. Your air conditioner not only cools   down the temperature, but dehumidifies   the air as well.    Air purity: The air filter removes dust particles   from the room air, creating a healthier room   atmosphere.    Airflow: The air conditioner regulates the   airflow, allowing the flow to be directed and   ensuring optimal air circulation    Temperature: the main function of an air   conditioner is to draw hot air out of the room.   **Note: Avoid being directly in front of the cold airflow and do not direct it onto people. To ensure the   optimal efficiency of the unit,we advise you to keep doors and windows closed, and to take into account   the surface of the walls and windows exposed to the sun. In this case, in order to optimize the functioning   of your air conditioner, we recommend partially closing window coverings.   2 IMPORTANT INSTRUCTIONS   Do not install and use your air conditioner before completely reading these instructions.   This will help you optimize the operation of your air conditioner. Make sure that you haven’t   lost the small box placed on the top of the unit; it contains all accessories, which are   essential for use.   The following advice and instructions should be followed closely:   1. Your unit must always be used in an   upright position because it contains a   cooling agent.   Failure to comply with these instructions   may damage the unit and will invalidate the   warranty.   Using your unit in wine cellars or in any   room with a temperature under 61°F is not   recommended.   2. After unpacking, place the unit upright to   allow the cooling agent to stabilize, and wait   3 hours before use.   ENERGY SAVING TIPS    Each person present in a room provides   between 100 Watts and 150 Watts of heat.   Consequently, the more people there are in a   room, the less effective the unit will be in   cooling.    Blocking of the filter reduces the efficiency   of the air and increases its power   consumption by up to 6%.    Avoid opening doors frequently.   TECHNICAL SPECIFICATIONS   12,000 BTU/Hour   Cooling Capacity   Power Input   1200 Watts / 10Amps   R-22   Coolant   3 1/2 Pints / Hour (40 Liters / Day)   247 CFM (Cubic Feet / Minute)   61o - 90oF (16o - 32oC)   Moisture Removal   Airflow Volume   Temperature Range   Voltage/Frequency   Product Dimension (WxHxD)   120V/60Hz   18 in (W) x 16 1/2 in (D) x 35 in (H)   460mm(W) x 420mm(D) x 880mm(H)   6 Cubic Feet   Product Measurement   Product Weight   Net Weight: 97 lbs. / 44 kgs.   Gross Weight: 118 / 54 kgs.   9 1/2 feet   Drain Hose Length   11 1/2 inches (compressed); Extends up to 5 feet   Inside: 4 3/8 inches / Outside: 5 1/8 inches   2 3/4 Cups (0.65 Liters)   Exhaust Hose Length   Exhaust Hose Diameter   Condensation Tank Capacity   3 PARTS ILLUSTRATION   1 4 2 3 5 6 8 4 7 Rear View   4. Air Filter   Front View   1. Control Panel   2. Cold Air Outlet   3. Adjustable Louvers   5. Rating Plate   6. Drain Hose (A)   7. Drain Hose (B)   8. Exhaust Air Outlet   Control Panel   1. Power ON/OFF Button   2. Function Button   6. LED Display   7. Alarm Indicator Light   3. Timer Setting Button   4. A/C Fan Speed Button   5. Sleep Function Button   8. Thermostat Temperature Setting Buttons   9. Air Conditioner Indicator Light   10. Dehumidifier Indicator Light   4 CONTINUOUS DRAIN FEATURE   There are two continuous drain features in this unit.   1.Drain (A) runs through the exhaust hose and offers continuous drainage via a built-in pump. When the cap is   on Drain (B) and the condensation tank fills to capacity, Drain (A)’s pump will automatically turn on and pump   the condensation out of the unit. If the exhaust hose is installed more than 5.9 feet above the ground,   Drain (A)’s pump will not work and the condensation must then be drained from Drain (B).   2. Drain (B) is located at the bottom of the rear of the unit and offers continuous drainage via gravity. To use   Drain (B), place a shallow pan underneath the drain outlet and remove the rubber cap. In order to avoid   spilling water while moving the unit from room to room, please drain the condensation via Drain (B) before   moving the unit. In addition, whenever you will not be using the unit for a extended period of time, such as at   the end of the season, use Drain (B) to make sure the condensation is completely drained from the unit.   MAX   DRAIN (A)   DRAIN (B)   5 EXHUAST KIT INSTALLATION   WINDOW INSTALLATION   Clips   7 3 1 6 Panel (A)   Panel (B)   Window Panel Kit   4 2 5 ExhaustWindowpanel   Kit adjusts from 33 inches to   56 inches to fit various   windowsizes.   1. Drain Hose (A)   4. White Hose Connector   5. Wall/Window Panel Adapter   6. Adapter Cover   2. Grey Hose Connector   3. Exhaust Hose   7. Adjustable Window Panel   NOTE: FOR DEHUMIDIFYING MODE, THE EXHAUST HOSE DOES NOT NEED TO BE INSTALLED.   1) Remove the adapter cover from the wall/window panel adapter and attach the wall/window panel adapter to Panel (A) of   the window kit.   2) Attach Panel (A) to Panel (B), place the combined panel inside your window frame and adjust the size of the combined   panels to fit the window opening by sliding Panel (B) upwards or sideways.   3) Use the clips attached to Panel (A) to lock the panels into place. The clips are to be placed on the “L” shaped edges of   Panel (A) at the point where Panel (A) meets Panel (B).   4) Close the window up against the panels to secure them in the window frame.   5) Twist the grey connector onto the exhaust hose and then pass Drain (A) through the exhaust hose before connecting the   grey connector to the back of the unit (you must do this whether or not you use Drain (A)).   6) Twist the white connector onto the opposite end of the exhaust hose, take Drain (A) and feed it through the wall/window   adapter, and snap-lock the white connector into the wall/window panel adapter.   NOTE: For the most effective cooling, remove the adapter’s cover   when the unit is running.   NOTE: Drain (A) will not work if it’s raised more than 5.9 feet   above the ground.   If you need to extend your exhaust hose, it may be   extended 5 feet only using 4 in PVC pipe (available at   your local hardware store) for a maximum exhaust   length of 10 feet. DO NOT USE DRYER TYPE   EXHAUST HOSE TO LENGTHEN EXHAUST.   Horizontal Vertical   6 EXHUAST KIT INSTALLATION (CONTINUED)   WALL INSTALLATION   1. Drain Hose (A)   3 2. Grey Hose Connector   3. ExhaustHose   5 1 4. WhiteHoseConnector   5. Wall/Window Panel Adapter   6. Adapter Cover   2 4 Wall   6 1) Drill a 5 1/2 inch hole in the wall at least 16 inches above the floor line. You should take precautions   by having a carpenter or an electrician select the location for the hole and make the hole for you in   order to ensure your safety and to avoid cutting into a support beam or electrical wires.   2) Install the wall/window adapter into the 5 1/2 inch hole and mark the screw holes.   3) Remove the wall/window adapter and drill four 1/8 inch diameter holes at these marks.   4) Place a 6 inch long piece of 4 inch PVC pipe (not included) in the wall to direct the exhaust’s airflow.   5) Place the wall/window adaptor back into the hole and install it onto the wall by   fastening the four screws into the predrilled holes.   6) Twist the grey connector onto the exhaust hose and then pass Drain (A) through the exhaust hose before   connecting the grey connector to the back of the unit (you must do this whether or not you use Drain (A)).   7) Twist the white connector onto the opposite end of the exhaust hose, take Drain (A) and feed it through the   wall/window adapter, then snap-lock the white connector into the wall/window panel adapter.   Flap flips up to cover hole   when unit is not in use.   Kit mounts on inside wall   This unit can also be vented through the ceiling. Please consult   with an air conditioning professional for ceiling venting installation.   If you need to extend your exhaust hose, it may be extended 5 feet only ,using 4 inch PVC pipe   (available at your local hardware store), for a maximum exhaust length of 10 feet.   DO NOT USE DRYER TYPE EXHAUST HOSE TO LENGTHEN THE EXHAUST.   7 OPERATING INSTRUCTIONS AND FUNCTIONS   The air conditioner can now be plugged into a 120V/60Hz dedicated 15amp socket. You are   advised not to use an extension cord, however, if this is unaviodable, the extension cord must be   14 gauge, grounded at both ends and not more than 30 feet long.   The compressor is an essential component of the appliance for producing cold air. This   appliance is fitted with a thermal protection device which allows the compressor to be   started only after a time delay of up to three minutes.   Soft Touch Control Functions   CONTROL PANEL FUNCTIONS   1. POWER BUTTON: Press to turn unit “ON” or “OFF”.   (NOTE: The Compressor requires up to 3 minutes to start   from either being switched on, or when changing from   dehumidify to any air conditioning cycle chosen).   4. A/C FAN SPEED: Press the speed button to select   either LOW, MEDIUM, HIGH or AUTO A/C fan speed.   When using the auto function, the unit will start at   maximum speed. As the room temperature changes   up or down, the fan speed will adjust accordingly.   When the room temperature reaches the set   temperature, the compressor will shut off, as indicated   by the blinking air conditioner indicator light on the   control panel, and the fan will continue to operate to   circulate the air.   2. FUNCTION BUTTON: Press this button to select the   air conditioning function or dehumidification function.   3. TIMER BUTTON: Programmable timer ON/OFF   button.   TIMER-ON FUNCTION: The unit can be set to   automatically turn on the unit.   1. While the unit is off, press the “TIMER” button to set the   number of hours (from 1 to 12 hours), from the current time,   that you would like the unit to turn on.   2. When the time elapses, the unit will turn on automatically.   3. If you press the “POWER” key before the time elapses,   the set time will be canceled and the unit will turn on.   TIMER-OFF FUNCTION: The unit can be set to   automatically turn off.   1. While the unit is on, press the “TIMER” button to set the   number of hours (from 1 to 12 hours), from the current time,   that you would like the unit to turn off.   5. SLEEP CONTROL FUNCTION: This function is   designed to: (a) gradually increase the thermostat   temperature, and hence the room temperature, as you fall   asleep, and (b) shut the unit off. To set the “Sleep Comfort”   mode, first press the sleep button. Then set the number of   hours, from the current time, that you would like the unit to   remain on by pressing the timer button until the desired   hours are indicated on the L.E.D. display. The temperature   setting may be varied in the “Sleep Comfort” mode by   pressing the “UP” or “DOWN” buttons. For each press, the   temperature will be increased or decreased by 1ºF. During   the course of this cycle, the microprocessor memory will   gradually raise the preset temperature 2º - 3ºF over a two   hour period, maintain that temperature for the balance of   the time set, and then shut the unit off.   2. When the time elapses, the unit will turn off automatically.   3. If you press the “POWER” key before the time elapses,   the set time will be canceled and the unit will turn off.   CONTINUED ON NEXT PAGE   8 REMOTE CONTROL FUNCTIONS   CONTROL PANEL FUNCTIONS CONTINUED   6. L.C.D. DISPLAY: Indicates the room temperature and   the timer and temperature settings. The unit’s LED displays   the room temperature as soon as the power is turned on   and after the timer or temperature is set.   COOL   (1)   7. ALARM INDICATOR LIGHT: This light will illuminate   and this unit will shut off when the condensate tank is full   and the unit cannot drain. The light will remain on and the   unit will remain off until the condensation is drained through   Drain (B). Please refer to the TROUBLESHOOTING GUIDE   in this manual for further information.   DRY   A/C   AUTO   LO   (2)   MED   HI   SET   (3)   8. TEMPERATURE REGULATION BUTTONS (UP   AND DOWN): These buttons raise and lower the   thermostat temperature setting by 1º each time they are   pressed, ranging from 61ºF - 90ºF.   (4)   SLEEP   TIMER   ON   OFF   HR   (5)   (6)   9. A/C INDICATOR LIGHT: Illuminates when the   compressor is on and stays solid while the compressor is   running. When the room temperature reaches the set   temperature, the compressor turns off and the light blinks   indicating that the unit has cooled the room to the set   temperature.   ON/OFF   10. DEHUMIDIFIER INDICATOR LIGHT: Press the   “FUNCTION” button to select the dehumidification mode.   When the dehumidification mode is on, the temperature   buttons and the fan speed buttons do not function and the   fan will operate on low speed. The dehumidifier indicator   light will illuminate and stay solid while the unit is   dehumidifying. When the humidity in the room is 50% or   lower, the compressor will not run, the unit will not   dehumidify, and the dehumidifier light will blink.   Remember, the exhaust hose does not need to be used in   dehumidifier mode.   1) Air Conditioning or   Dehumidifier Selector Button   2) A/C Fan Speed Selector Button   NOTE: This unit has a three-minute compressor delay   protection circuit. Thus, the compressor may take up to   three minutes to start from either being switched on or when   changing between the dehumidification and air   conditioning functions.   3) Thermostat Temperature   Setting UP and DOWN Buttons   4) Sleep Function Button   5) Timer Setting Button   6) Power ON/OFF Button   IF THERE IS A POWER INTERRUPTION WHILE THE   UNIT IS OPERATING, THE UNIT WILL NOT TURN BACK   ON AUTOMATICALLY WHEN THE POWER IS RE-   STORED. THE UNIT MUST BE TURNED BACK ON   MANUALLY. THE UNIT IS DESIGNED WITH THIS   SAFETY FEATURE TO PROTECT THE COMPRESSOR.   9 CLEANING THE UNIT   Before cleaning the unit, turn it off and unplug it from the outlet.   For safety reasons, never wash the air conditioner.   EXTERIOR SURFACES OF THE UNIT    Clean the air conditioner by using a damp sponge, and dry it with a clean, soft cloth.    Never use alcohol or any product containing solvents.   AIR FILTERS   The air filters located on the back of the unit collect dust contained in the air. To keep   the dust from clogging the unit, your unit must always be used with its air filters.    The build up of dust reduces the efficiency of the air conditioner. Therefore, the air filters must be   cleaned every two weeks, and more often if the machine operates in a dusty atmosphere.    If the filters are obstructed, the air conditioner will be less efficient.    Each air filter has a tab in the center and is secured to the unit by two clips on the top and two clips   on the bottom of the filter. Remove the air filters with the unit switched off, by pulling the tab   towards you.    Clean the filters with a vacuum cleaner. If the filters are very dirty, you can wash them in warm   water (never use hot or soapy water). Make sure that the air filters are completely dry before   putting them back on the unit.    Do not bend the filters.   LONG TERM STORAGE   At the end of the season, or when you do not plan to use the unit for an   extended period of time, we recommend that you take the following steps:    Drain excess water from the pan through Drain (B).    Run the unit for 3 to 4 hours in fan mode. The fan mode can be activated by running the air   conditioning function without the compressor, which will occur if you set the thermostat   temperature above the room temperature. This will thoroughly dry the inside of the unit.    Disconnect the unit and wrap the power cord and plug.    Clean the unit and store it, protecting it from dust.    Store the unit in an upright position. Keep it in a cool, dry place and away from sunshine.   10   TROUBLESHOOTING GUIDE   When the air conditioner does not work, it is sometimes a minor problem which the   user can handle. Before calling customer service, please check the following   points to see if they solve your problem. Additional troubleshooting tips may be   Problem   Probable Causes   Solutions   The air conditioner/dehumidifier   doesn’t work.   1) Plug not properly inserted into   wall socket.   1) Plug the appliance in properly.   2) Insufficient amount of amperage   to start unit.   2) Check circuit board for   15-20amp fuse availability.   3) Water tank is full / alarm light   illuminated.   3) Check Drain (A) for obstruction   and/or empty Drain (B).   The air conditioner cuts off.   1) Exhaust hose too long, run   incorrectly or kinked.   1) Exhaust hose can only be   extended using max. 5’ of 4”   PVC pipe for a total exhaust   length of 10’.   2) Unit too close to wall or object.   2) Unit should be at least 1 ½’   away from walls and objects   3) Flap vent obstructs wall   exhaust.   3) Use screen instead of Flap vent   for wall exhaust.   4) Ceiling or basement does not   have ample ventilation.   4) Unit will overheat if the exhaust   cannot fully vent.   5) The “timer off” function has been   activated.   5) Push the power button to turn unit   on.   1) In the A/C function, the ambient   temperature has reached the set   temperature and therefore the   compressor has shut off.   1) This is normal. Set the   temperature lower to turn the   compressor back on.   The air conditioner/   dehumidifier LED indicator   light blinks.   2) In the dehumidifier function, the   humidity in the room is 50% or   lower and therefore the   2) This is normal.   compressor is not running.   The LED display shows the   unit is set, but the unit is not   running.   The unit’s “timer on” feature is   activated.   1) This is normal.   2) Push the Power button to turn the   unit on and deactivate the “timer   on” feature.   The Alarm Indicator Light is   Illuminated   The condensate tank is full and   the unit cannot drain. This safety   feature turns off the unit to protect   the unit and prevent the   If you are using Drain (A), make   sure that the drain hose is no more   than 5.9 feet above the ground. If   Drain (A) still does not work, the   condensate must be drained   condensate tank from overflowing.   through Drain (B). After draining   the tank, you should be able to   restart and use the unit.   11   PRODUCT LIMITED WARRANTY   This warranty applies to new product only and excludes optional accessories and attachments. Extended   compressor warranty applies only to product with manufacturing dates beginning January 1,1998.   During the first year from the date of original purchase, this product is warranted to be free from defects in materials   or workmanship under normal use, service and maintenance. During the 2nd through 5th years from the date of   original purchase, the compressor (part only) is warranted against defects in material or workmanship under normal   use, service and maintenance.   This warranty applies to the original purchaser subject to the following terms and conditions:   WHAT IS COVERED: The product’s components as originally installed by the manufacturer that are defective in   materials or workmanship under normal use, service and maintenance.   WHAT IS NOT COVERED BY THIS WARRANTY: This warranty does not extend to or cover:   (1) Any defect due to the negligence of others; failure to install, operate or maintain unit or accessories and   attachments in accordance with installation instructions (instruction manual is furnished with each new unit);   unreasonable use; accidents; alteration, use of unauthorized or non-standardized parts, accessories and   attachments; acts of God; theft; vandalism; blown fuses; electrical malfunction. (i.e., as resulting from power surges,   shorted or overloaded circuits outlets of wiring utility power quality, etc.), incorrect installation; use of any power   source other than that specified on the Product’s specification label; or repair by anyone other than a service facility   specified by an authorized WINDCHASER representative.   (2) Diagnostic, troubleshooting and travel costs.   (3) Operation and usage orientation costs.   (4) Performance or operation certification and testing costs.   (5) Normal wear and tear of parts including but not limited to, hoses, cables, accessories and attachments.   (6) Shipping, handling, packaging and delivery costs of the product, parts or accessories.   (7) Shipping, handing and freight damages.   (8) Diagnosing, repairing, removing, installing, shipping, servicing and/ or handling costs of either defective parts or   replacement parts as relating to Extended 4 Year Compressor Warranty.   WHO IS COVERED: The original purchaser from a retailer or liscensed air conditioning contractor.   WHAT WE WILL DO: During the first year, WINDCHASER will either repair or replace, at its option, all defective   product components free of charge that are covered by this Limited Warranty on a carry-in basis to the authorized   WINDCHASER repair facility. During the second through fifth years, WINDCHASER at its option, will provide a new   or remanufactured compressor (part only) free of charge as covered by this Limited Warranty on a carry-in basis to   the authorized WINDCHASER repair facility.   WHAT YOU MUST DO FOR WARRANTY SERVICE: You must return the defective Product to your authorized   WINDCHASER repair facility along with a copy of the bill of sale or credit card charge receipt or other document   evidencing the date of original purchase and the product’s model number.   12    Before returning this product, call for troubleshooting assistance. If you purchased the unit from a   retailer, contact WindChaser Products customer service at 1-800-405-2943 for assistance. If you   purchased this unit from an air conditioning wholesaler or contractor, please contact them first for   assistance; if they are unable to assist you, contact WINDCHASER.    Do not return the unit, components or parts to WINDCHASER without prior written approval and   return authorization from WINDCHASER.    You are responsible for prepaying all shipping, handling, packaging and delivery costs to and from   the warranty repair center.    WINDCHASER, its dealers, distributors and representatives are not responsible for damage   resulting from improper packing and or mishandling by a shipper.   THE FOREGOING EXPRESSES ALL OF WINDCHASER’S OBLIGATIONS AND LIABILITIES WITH RESPECT TO   THE QUALITY OF PRODUCT, ITS COMPONENTS, ACCESSORIES AND ATTACHMENTS FURNISHED. ALL   OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY OR   FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. WINDCHASER SHALL NOT BE LIABLE FOR THE   LOSS OF USE OF THE PRODUCT, ITS COMPONENTS, ACCESSORIES AND ATTACHMENTS,   INCONVENIENCE, LOSS OR ANY OTHER DAMAGES, DIRECT OR CONSEQUENTIAL ARISING OUT OF THE   USE OF, OR INABILITY TO USE THE PRODUCT, ITS COMPONENTS AND ACCESSORIES OR DAMAGES   RESULTING FROM OR ATTRIBUTABLE TO DEFECTS IN THE PRODUCT, ITS COMPONENTS AND   ACCESSORIES.   NO ONE OTHER THAN WINDCHASER HAS AUTHORITY TO EXTEND OR MODIFY THE TERMS OF THIS   LIMITED WARRANTY IN ANY MANNER WHATSOEVER.   Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how   long an implied warranty lasts, so these limitations or exclusions may not apply to you. This limited warranty gives   you certain legal rights and you may also have other rights specific to your country, state or province.   For further information call:   CUSTOMER SERVICE DEPARTMENT:   TOLL FREE 1-800-405-2943   13   WindChaser Products: Developers of Fans,   Heaters, Air-Treatment Products and   Portable and Mini-Split Air-Conditioners   WindChaser Products, Inc.   4130 Del Rey Avenue   Marina Del Rey, CA 90292   Phone: (310) 827-8615   Toll Free: (800) 405-2943   Fax: (310) 827-8566   International Comfort Products Corporation (Canada)   6060 Burnside Court, Unit 1• Mississauga, ON L5T 2T5 • 905-795-8113• 1-800-314-1112   PACR12-OM-E-04   |