| OWNERS MANUAL   CONVECTION PROPANE CONSTRUCTION HEATERS   Model   100R-NG   QUESTIONS?   MISSING / DAMAGED PARTS   Please do not return this product to the store.   If a part is damaged or missing, simply e-mail us at   [email protected], or visit our website at   Service Department at (888) 619-7060.   We will be happy to assist you!   You can register your heater on line at   STOP   TABLE OF CONTENTS   HEATER SPECIFICATIONS................................................................................................................ 2   WARNINGS .................................................................................................................................. 2   OPERATING PRECAUTIONS ............................................................................................................. 3   SAFETY PRECAUTIONS .................................................................................................................... 3   ODOR FADE WARNING ...................................................................................................................... 4   OPERATING INSTRUCTIONS ............................................................................................................ 5   SERVICING ......................................................................................................................................... 5   PARTS LIST ........................................................................................................................................ 6   WARRANTY......................................................................................................................................... 7   SERVICE CENTERS .......................................................................................................................... 7   INSTRUCTIONS FOR ORDERING PARTS ........................................................................................ 7   WARRANTY REGISTRATION ............................................................................................................. 9   RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE   © 2002 Scheu Products Company   Model   100R-NG   SAFETY PRECAUTIONS   OPERATING PRECAUTIONS   This is a natural gas, direct-fired, radiant heater. It's intended   use is primarily temporary heating of buildings under   construction, alteration or repair.   1.Check the heater thoroughly for damage. DO NOT operate a   damaged heater.   2.DO NOT modify the heater or operate a heater which has   been modified from its original condition.   3.Use only natural gas.   4.Provide at least 5" W.C. but not over 1/2 psig to the heater   inlet (regulator inlet).   When the heater is to be operated in the presence of other   people the user is responsible for properly acquainting those   present with the safety precautions and instructions, and of   thehazardsinvolved.   5.Use an appropriate hose or flexible connector not over 10 ft.   (3.05m) in length.   6.Operate the heater only with the 4" W.C.regulator   provided by the factory.   7.For indoor use only. Area must be well ventilated.   (Figure1).   8.If at any time gas odor is detected, IMMEDIATELY   DISCONTINUE operation until the source of gas has been   located and corrected. (See Odor Fade Warnings on page   4.)   9.Install the heater such that is is not directly exposed to water   spray, rain and/or dripping water.   10.Maintain minimum clearance from normal combustible   material (like paper). (Figure 2). Locate 10 ft. from canvas   tarpaulins or similar coverings and secure them to prevent   flapping or movement due to wind action.   11.Due to the high surface and exhaust temperatures, adults   and children must observe clearances to avoid burns or   clothing ignition.   12. Operate only on a stable, level surface.   13.Do not move, handle or service while hot or burning.   14.Use only in accordance with local codes or, in the absence   of local codes, with the Standard for the Storage and   Handling of Liquefied Petroleum Gases ANSI/NFPA 58.   Figure 1   Figure 2   VENTILATION:Minimumopeningsrequired   MINIMUMCLEARANCE:Fromnormalcombustiblematerial   Opening   Opening   Radiant   Forced Air   Heater   near floor near ceiling   Clearance   Infrared   Convection Forced Air 7000-FACV   Infrared ............................................................... 1 ft2   Convection (25-VC) ........................................... 1 ft2   Convection (All others) ...................................... 2 ft2   Radiant ................................................................ 2 ft2   Forced air (30K-125K BTU/HR).......................... 1 ft2   Forced air (150-FAST, SPC-150T) .................... 2 ft2   Forced air (3500-FACV, SPC-350) .................... 3 ft2   Forced air (7000-FACV) .................................... 4 ft2   .....................   .....................   .....................   .....................   .....................   .....................   .....................   .....................   1 ft2   1 ft2   2 ft2   2 ft2   1 ft2   2 ft2   3 ft2   4 ft2   From floor ........................................................... 0 ft .............. 0 ft   From outlet .......................................................... 6 ft .............. 10 ft   From sides ................ 3 ft ............ 4 ft ............... 2 ft .............. 3 ft   From top ....................................... 6 ft ............... 3 ft .............. 5 ft   From front ................. 6 ft   From rear .................. 2 ft   Locate 10 ft. from canvas or plastic tarpaulins or similar coverings and   secure them to prevent flapping or movement due to wind action.   Page-3-   Model   100R-NG   ODOR FADE WARNING   WARNING   heater dataplate, or contact the Scheu Products Company to   determine combustion air ventilation requirements of the   heater.   • Lack of proper ventilation air will lead to improper   combustion.   • Improper combustion can lead to carbon monoxide   poisoning leading to serious injury or death. Symptom of   carbon monoxide poisoning can include headaches   dizziness and difficulty in breathing.   AsphyxiationHazard   • Do not use this heater for heating human living quarters.   • Do not use in unventilated areas.   • The flow of combustion and ventilation air must not be   obstructed.   • Proper ventilation air must be provided to support the   combustion air requirements of the heater being used.   • Refer to the specification section of the heater’s manual,   FUELGASODOR   LP gas and natural gas have man-made odorants added specifically for detection of fuel gas leaks.   If a gas leak occurs you should be able to smell the fuel gas. Since Propane (LP) is heavier than air you should smell for the gas   odorlowtothefloor.ANYGASODORISYOURSIGNALTOGOINTOIMMEDIATEACTION!   • Do not take any action that could ignite the fuel gas. Do not   operate any electrical switches. Do not pull any power   supply or extension cords. Do not light matches or any other   source of flame. Do not use your telephone.   • Get everyone out of the building and away from the area   immediately.   • Close all propane (LP) gas tank or cylinder fuel supply   valves, or the main fuel supply valve located at the meter if   you use natural gas.   areas. When you have reason to suspect a propane leak,   keep out of all low areas.   • Use your neighbor’s phone and call your fuel gas supplier   and your fire department. Do not re-enter the building or   area.   • Stay out of the building and away from the area until   declared safe by the firefighters and your fuel gas supplier.   • FINALLY, let the fuel gas service person and the firefighters   check for escaped gas. Have them air out the building and   area before you return. Properly trained service people must   repair any leaks, check for further leakages, and then relight   the appliance for you.   • Propane (LP) gas is heavier than air and may settle in low   ODORFADING-NOODORDETECTED   • The odorant in propane (LP) gas and natural gas is   colorless and the intensity of its odor can fade under   some circumstances.   • If there is an underground leak, the movement of gas   through the soil can filter the odorant.   • Propane (LP) gas odor may differ in intensity at different   levels. Since Propane (LP) gas is heavier than air, there   may be more odor at lower levels.   • Some people cannot smell well. Some people cannot smell   the odor of the man-made chemical added to propane (LP)   or natural gas. You must determine if you can smell the   odorant in these fuel gases.   • Learn to recognize the odor of propane (LP) gas and natural   gas. Local propane (LP) gas dealers will be more than   happy to give you a scratch and sniff pamphlet. Use it to   become familiar with the fuel gas odor.   • Always be sensitive to the slightest gas odor. If you   continue to detect any gas odor, no matter how small, treat it   as a serious leak. Immediately go into action as discussed   previously.   • Smoking can decrease your ability to smell. Being around   an odor for a period of time can affect your sensitivity to that   particular odor. Odors present in animal confinement   buildings can mask fuel gas odor.   ATTENTION-CRITICALPOINTSTOREMEMBER!   • Propane (LP) gas has a distinctive odor. Learn to recognize   these odors. (Reference Fuel Gas Odor and Odor Fading   sections above.   • Even If you are not property trained in the service and repair   of the heater, ALWAYS be consciously aware of the odors of   propane (LP) gas and natural gas.   • A periodic sniff test around the heater or at the heater’s   joints; i.e. hose, connections, etc., is a good safety practice   under any conditions. If you smell even a small amount of   gas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY.   DONOTWAIT!   • If you have not been properly trained in repair and service of   propane (LP) gas then do not attempt to light heater,   perform service or repairs, or make any adjustments to the   heater on the propane (LP) gas fuel system.   Page-4-   MODEL   100-RANG   OPERATING INSTRUCTIONS   SERVICING   PREPARINGFOROPERATION   A hazardous condition may result if a heater is used that has   been modified or is not functiong properly. When the heater is   working properly:   1.Check the heater for possible shipping damage. If any is   found, immediately notify your dealer.   2.Follow all of the "Safety Precautions".   *The flame is contained within the heater.   *The flame is essentially blue with perhaps some   yellow tipping.   *There is no strong disagreeable odor, eye burning or   other physical discomfort.   3.Install plumbing to a low pressure (1/2 psig Maximum)   source of natural gas, using a minimum 3/4" ID hose or   flexible connector not over 10 feet in length.   4.Connect the hose to the heater at the 1/2" SAE flare fitting at   the inlet.   *There is no smoke or soot internal or external to the   heater.   5.Securely tighten all gas connections.   6.Open the gas cock and leak check all gas connections with a   solution of soap and water. DO NOT USE A FLAME.   *There are no unplanned or unexplained shut downs of   the heater.   START   The parts list show the heater as it was constructed. Do not use   a heater which is different from that shown. For this heater, the   regulator must be set to supply 4" water column (W.C.) outlet   pressure. If there is any uncertainty about the regulator setting,   havie checked.   1.Fully open the gas cock at the natural gas source.   2.Place control knob of the safety pilot valve in pilot position   and depress the knob admitting gas to pilot. Push and   release piezo button until the pilot lights, multiple tries may   be necessary. Alternately place a lighted match near the   (pilot is above the valve sheild). If hose is filled with   air, allow a few minutes for gas to reach the pilot.   3.When pilot lights, continue to hold the button on the safety   pilot valve depressed for 30 seconds, then release.   4.If the pilot goes out, wait 5 minutes and repeat the start   procedures.   A heater which is not working right must be repaired, but only by   a trained, experienced service person. To find the service center   (888) 619-7060.   You may also obtain in-warranty or out-of-warranty service by   taking the product to your local service center.   5.When the pilot remains lit, turn the knob left 1/4 turn to the   "ON" position and the main burner will light.   In-warranty products will be repaired with no charge for either   parts or labor. Please include a breif statement indicating date,   place of purchase, the nature of the problem and proof of   purchase.   CAUTION; INADEQUATE FUEL SUPPLY or lowering burn   rate can cause sooting.   STOP   Out-of-warranty products will be repaired with a charge for parts   and labor.   1.Securely close the gas cock at the gas source.   2.Depress the control knob of the pilot valve and turn clockwise   to "OFF" position.   RESTARTAFTERSAFETYSHUTDOWN   1.Securely close gas cock at the gas source.   2.Wait 5 minutes.   3.Restart following "Start" procedures.   Page-5-   100RNG PARTS   Item   No.   Description   Qty.   Item   No.   Description   Qty.   16   17   18   19   20   21   22   * 24   * 26   27   * 3101   3102   6500   6259   6125   7253   6384   4222   7291   6473   3106   3105   6505   7161   8129   Louvered Emitter   Pan Hood   Fitting, 1/2" x Close Nipple   Regulator, 4" W.C.   Fitting, Male Connector   Orifice Pilot   Label, Natural Gas Only   Bracket, Piezo   Label, Model/Operating Instructions   Ignitor, Piezo   Leg Base, Side   Leg Base, Front   Fitting, Male Connector   Nut, Piezo   Electrode   1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 2 3 4 5 6 7 8 9 10   11   * 13   14   15   0814   3095   1074   6113   1510   1072   7616   6067   1837   6137   6234   7290   1594   3683   1098   Base Assembly   Ballast   Valve Shield Assembly   Orifice, #55 Drill   Pilot Assembly   Manifold Assembly   Thermoelectric Valve   Spacer, 5/16" id x 1/2"   Pilot Tube Assembly   Fitting, Female Elbow   Thermocouple, 16"   Manual, Operating Instructions   Bracket, Pilot Mounting Assembly   Floor Shield Assembly   Emitter Grill   1 1 1 1 1 1 1 5 1 1 1 1 1 1 1 * * Page-6-   Model   100RNG   or usage of trade. This warranty will not apply to any product   WARRANTY   which has been repaired or altered outside of the California   factory in any respect which in our judgment affects its condition   or operation.   We are pleased that you have selected our product and take   this opportunity to assure you that qualified service facilities are   available if required. With the cooperation of independent   dealers, a nationwide network of authorized servicing dealers is   available for your servicing requirements.   Some states do not allow the exclusion or limitation of   incidental or consequential damages, so the above limitation or   exclusion may not apply to you. This Warranty gives you specific   legal rights, and you may have other rights which vary from state   to state.   Should your product require servicing, read the section of the   manual entitled “Servicing”.   SERVICE CENTERS   Who gets the warranty? The warranty is limited to the consumer   who originally purchases the product.   Scheu Products Company has over 1,000 service centers   throughout North America. Call (888) 619-7060 or email   [email protected] to request the service center nearest you.   Include the Make and model of your heater in any emails.   What is covered? This limited warranty covers all imperfections   in workmanship and material.   What is not covered? This limited warranty does not cover   damage resulting from accident, misuse or abuse, lack of   proper maintenance, affixing of any attachments not provided   with the products, or loss of parts. IN NO EVENT SHALL   SCHEU PRODUCTS COMPANY BE LIABLE FOR ANY SPECIAL,   INCIDENTAL OR CONSEQUENTIAL DAMAGES NOR FOR ANY   DAMAGESRESULTINGFROMMISUSEORMODIFICATIONOF   THIS PRODUCT.   INSTRUCTIONS FOR ORDERING   PARTS   We recommend that only parts supplied by the manufacturer be   used on this unit. A locally purchased part may appear to be   identical, although in reality it might endanger the heater or the   persons operating the heater.   The heater should be serviced only by a trained, experienced   service person.   Registering this heater within 10 days of date of purchase   ensures the buyer the protection as stated on our limited   warranty form.   Read the section on "Servicing" before ordering parts.   For parts orders, call 888-619-7060 or e-mail us at   [email protected]. Please have the model number of your   heater and the replacement part number when placing your   order.   LIMITEDWARRANTY   The company warrants this product to be free from   imperfections in material or workmanship, under normal and   proper use in accordance with instructions of The Company, for   a period of one year from the date of delivery to the buyer. The   Company, at its option, will repair or replace (f.o.b. factory,   California) products returned by the buyer to the factory,   California, transportation prepaid within said one year period   and found by the Company to have imperfections in material or   workmanship.   If a part is damaged or missing, simply e-mail us at   [email protected], visit our website at scheuco.com, or call   our Technical Support Department at (888) 619-7060.   Address any Warranty Claims to the Customer Service   Department, Scheu Products Company, Incorporated, P.O. Box   250, Upland, California 91785, or e-mail us at   [email protected]. Include your name, address and telephone   number and include details concerning the claim. Also, supply   us with the purchase date and the name and address of the   dealer from whom you purchased our product.   The foregoing is the full extent of the responsibility of the   Company. There are no other warranties, express or implied.   Specifically there is no warranty of fitness for a particular   purpose and there is no warranty of merchantability. In no event   shall the Company be liable for delay caused by imperfections,   for consequential damages, or for any charges of the expense   of any nature incurred without its written consent. The cost of   repair or replacement shall be the exclusive remedy for any   breach of warranty. There is no warranty against infringement of   the like and no implied warranty arising from course of dealing   Page-7-   Hand print only. Use black or blue ink pen to fill in this form. Cross or check inside the circle.   Warranty Registration   Your Information   First Name   Mailing Address   City   Last name   - State   Postal code   E-mail Address   <$9,999   $10,000 to $19,999   30-39 years   >$50,000   Annual house hold income before tax   $20,000 to $34,999   $20,000 to $34,999   Age of Purchaser   <20 years   20-29 years   40-49 years   50-59 years   >60 years   Fold Here   Your Preferences   In choosing your heater the following categories   were:   Male   Who selected the heater?   Female   Both   Somewhat   Important   Very   Important   Important   Individual   Business   Heater will be used by?   Features   Portability   Price   How did you learn   about our heater?   Advertising   Store display   Other   Relative/friend   Previously owned heater   Quality   Sudden cold weather   Emergency backup heat   Hard to heat location   Other   What prompted you to   buy your heater?   Replaces old model   Heater on sale   Heat Output   Warranty   Serviceability   Fuel economy   Ease of use   Size   Construction project   Warehouse   Patio   Construction site   Shop   Where will you use the   heater?   Other   Fold Here   Product Information   / / - Model Number (Located on a black and white label on heater)   National Riverside   S/N (Located on a silver label on heater)   Date of Purchase (MM/DD/YY)   Cost of Heater ($)   All Pro   Universal   Brand Name   Store Information where heater was purchased   Store Name   State   City   Type of Store   Hardware   Home Center   Warehouse Retailer   Discount Store   Farm Supply   Contractor’s Supply   Other   -9 Registering this heater within 10 days of purchase ensures the buyer the protection as stated on our limited warranty form.   SCHEU PRODUCTS COMPANY, INC   ATTN: MARKETING DEPARTMENT   8855 BAKER AVENUE   RANCHO CUCAMONGA, CA 91730   Visit our website for product information, technical support, customer service, and warranty registration at:   WWW.ALLPRO-HEATERS.COM for All-Pro products or WWW.UNVERISAL-HEATERS.COM for Universal products.   Page-10-   |