| 13 SEER Mini Split Air Conditioner   with Heat Pump and Back up Electric Heat Strip   KFTHP-12-ID/KFTHP-12-OD   KFTHP-18-ID/KFTHP-18-OD   KFTHP-24-ID/KFTHP-24-OD   R T T K CM   US   C I E 3119233   1 Safety Precautions   Symbols in this Use and Care Manual are interpreted as shown below.   Be sure to follow this instruction.   WARNING! DANGER!   CAREFUL! Pay Attention.   Remove the power source plug from a socket.   Warning: Incorrect handling could cause a serious   hazard, such as death, serious injury, etc.   Grounding is essential.   Keep the power supply   circuit breaker or plug   from dirt. Connect the   power supply cord to it   firmly and correctly,   Do not use the power   supply circuit breaker or   pull off the plug to turn it   off during operation. This   may cause a fire due to   spark, etc.   Use correct power supply in accordance with the   rating plate requirement. Otherwise, serious faults   or hazard such as a fire could occurt.   If the supply cord is damaged,it must be replaced   by the manufacturer,its service agent or similarly   qualified persons in order to avoid a hazard.   ON   ON   OFF   OFF   or hazard could occur.   IDo not stand in front of indoor   unit for extended periods of   time due to health   Do not tangle, pull or press   the power supply cord,   as this cord will be   damaged and an   electric shock or fire   could occur.   Never insert a stick or similar obstacle   to the unit. When   the fan rotates at high   speed, this may   cause an injury.   hazard.   Do not repair the appliance by yourself.   If this is done incorrectly,   it may cause an electric   shock, etc.   S LEE   P T I M E R O N OFF   FEEL   AUTO   HI   MED   LO   If malfunction occurs turn   off at remote control first   before turning off main   power.   C OOL   DRY   FAN   HEAT   S WING   SLEEP   TIMER   FAN   SWING   MODE   ON/OFF   Prevent the air flow from   reaching the gas burners   and stoves.   It is the user's responsibility to ground   the appliance according   to local codes or   Do not put any   objects on the   outdoor unit.   ordinances by a licenced   technician.   Do not touch the operation buttons   when your hands are wet.   Check that the plug is not covered with dust and   make sure to insert it firmly so that it does not get   loosened.   When not using the system for a long time,   remove the plug from the socket to   ensure safety.   Do not use extension cords   and do not connect   the air conditioner to a   socket to which other   electric appliances are   connected.   Fully insert the   plug firmly.   If the plug is covered with dust,it could cause   a fire.   If the plug is coverd with dust or improperly   inserted, thes may cause electric shock or fire.   If abnormal conditions occur,such as smell   of burning,immediately stop the system'   operation,remove the power plug and   consult your Dealer.   Make sure to use a fuse of proper   electric rating.   Do not wash the air conditioner with water.   Use of steel or copper   wire instead of a fuse is   strictly prohibited   and will void the warranty.   Operating the system under   abnormal conditions could result in   malfunctions,eletric shocks,fire,etc.   It could cause electric shocks.   Do not put anything on the unit,   especially vases which contain   water inside.   When the system is operating simultaneously   with a combustion apparatus,you should   air the room frequently.   Before cleaning the system,stop   the operation and remove the   power plug.   If water gets into the unit,it can   cause an electrical short and   this could cause electric   shocks.   Insufficient   Cleaning should never be   carried out while the inside   fans are running.   ventilation could   cause an oxygen   deficiency accident.   Notes:For the purpose of innovation and improvement,above products are subject to change without prior notice.   The air conditioner is not a toy , please keep away from children.The appliance shall not be installed in   the laundry area.   1 1 Identification of Parts   Indoor Unit   Air Intake   Front Panel   Emergency Panel   Display Panel   Air Outlet   Vertical Adjustment   Louver   Horizontal Adjustment   Louver   Charcoal Filter   (optional)   Electrostatic Filter   (optional)   Air Filter   Remote Control   Air Intake   Outdoor Unit   Pipes and Power   Connection Cord   Drain Hose   Note: Condensate water drains   at COOLING or DRY operation.   Air Outlet   The figures in this manual are based on the external view of a standard model.   Consequently, the shape may differ from that of the air conditioner you have selected.   2 1 Identification of Parts   Operating and Display   Temperature display   Display of environm-   ental temperature or   setting temperature   Run Indicator   Timer Indicator   It is on during   operation.   It lights up during   the set time.   Power Indicator   It lights up when   power supply is on.   Sleep Indicator   It lights up during the   set sleep function   The above operatingsketch map issuitable for Z BG series.   Signal Receives   Temperature display(optional)   Receive signal from the   remote control.   Display of environmental tem-   perature or setting temperature   Sleep Indicator   Timer Indicator   It lights up during the set time.   It lights up during the set   sleep function   Power Indicator   Run Indicator   It lights up when power   supply is on.   It is on during operation.   SLEEP   POWER   TIMER   RUN   The above operatingsketch map issuitable for C   BD BE BF BH and BJseries.   D E F G H J K M N V Z Temperature display   Display of environm-   ental temperature or   setting temperature   Temperature display   Signal Receives   Receive signal from   the remote control.   Display of environm-   ental temperature or   setting temperature   Power Indicator   Run Indicator   It lights up when   power supply is on.   It is on during   operation.   Sleep Indicator   It lights up during the   set sleep function   Sleep Indicator   Timer Indicator   It lights up during the   set sleep function   It lights up during the   set time.   Power Indicator   It lights up when   power supply is on.   The above operating sketch map is suitable   for L R and Y series.   The above operating sketch map is suitable   for Q series.   Emergency Button   Used to control the unit when the   remote control is out of work.   This way of operation is suitable   for C D   Z series.   N R L M Y and   ON/OFF   Emergency Button   Used to control the unit when the   remote controller is out of work.   This way of operationis suitable for   ON/OFF   E F G H J K Q Z BD   BE BF BG BH and BJ series.   Remarks:When remote controlis not working properly,,open the paneland you cansee emergency   button there,(see above picture).The emergency buttonfor 15K 16K 18K 22K 24K   28K and 30Kseries is atthe top right,see ON/OFF button there.   The shape and position of the switches and indicators may vary from different models,but their function are simiar.   3 1 Remote Control   Remote Control   The remote control transmits signals to the system.   ON/OFF button   Used to start and stop operation .   Signal Transmitting Window   Transmits signals to the system.   TIMER button   Used to select TIMER operation.   UP button (TOO COOL button)   Setting Display   Used to increase the set room temperature (60 f ~87 f)   and time(0.5~24h or 1~12h ).   DOWN button (TOO WARM button)   Used to decrease the set room temperature and time.   SLEEP button   Used to set or cancel sleep operation.It includes   normal-SLEEP( )and Comfortable-   SLEEP( ),but Comfortable-SLEEP is optional.   QUIET   9 12   3 QUIET   11   14   SWING control button   Used to adjust airflow direction.   7 6 FAN SPEED control button   Used to select the indoor fan motor speed:   5 4 2 8 Auto(   Mid(   or   or   ), High(   or   or   ) and Low(   or   ),   or or   ).   This function is invalid in sleep mode.   10   13   15   MODE button   Used to select the type of operation mode: FEEL(   ),   1 RESET   COOLING( ), DRY( ), FAN( ) AND HEATING   ( Only for Heat Pump).FEEL mode can select the operation   mode such as COOL,DRY,FAN,HEAT automatically depending on the room temperature,and the feel mode is   default setting at starting.   3D button(optional)   9 Used to start and stop 3D operation .Two-direction Airflow,the horizontal louver is opened different   direction in different mode(optional).   ECO. button(optional)   10   EC   (This function does not apply to the Units of KFTHP-12, KFTHP-18, and KFTHP-24. )   Used to start and stop ECONOMY operation .This function is invalid in SUPER mode.   DISPLAY button(optional)   11   12   Used to start and stop DISPLAY screen operation .   ANTI-MILDEW button(optional)   Used to start and stop ANTI-MILDEW operation .   SUPER button(optional)   (This function does not apply to the Units of KFTHP-12, KFTHP-18, and KFTHP-24. )   13   POWERFUL   Used to start and stop SUPER operation .   HEALTHY button(optional)   Used to start and stop HEALTHY operation .   14   15   RESET button(optional)   Used to restart.   Note:The position and figure of buttons are subject to the actual unit,;the relevant function   is not activated even if press the optional button which is invalid for some models;   Each mode and relevant function will be further specified in following pages.   4 1 Remote Control   Remote Control   Some remote control s display:   Feel Cool Dry Fan Heat   SLEEP TIMER ON TMIER OFF   AUTO   HIGH   MID   LOW   SWING   FEEL   COOL   Timer   off   Timer   on   C h C h DRY   FAN   HEAT   Auto Low Mid High Sleep Swing   Style.3   Style.1   Style.2.   FAN   SPEED   FEEL   COOL   DRY   AUTOQUIET   AIR   SWING   POWERFUL   C AUTO   hr   DELAY   FAN   HEAT   ON   OFF   ON   HEALTHY   TIMER   Style.5   Style.4   Note:The above remote control is only for reference, subject to the actual unit.   When inserting the batteries for the first time or each time the batteries are replaced   as they are discharged, the remote control mades a short Auto-Test :all the   symbols can be displayed are shown on the screen and keep 2 seconds,then the   symbol will flash from Cool to HEAT alternatively.For cooling only air con,   please press any button when the cooling symbol is flashing,the the remote controller   has been set as cooling only.For cooling and heating ,please press any button   when the heating symbol is flashing,then the remote control has been set as cooling   and heating.If none of the button is pressed within 10 seconds,the remote controller will   be set as cooling and heating automatically.Cooling only can use the remote   control which has cooling and heating function,but do not have the function of heating.   Although the heating is not running,remote control will still have some display.   The light of the remote control will be turned on by pressing any button for   1.5~3 seconds,and it will be turned off automatically if no button is pressed   within 10 seconds.   5 1 Remote Control   Remote Control   Please slide and remove the cover.   How to Insert the Batteries   1 Remove the battery cover according to the arrow direction.   Insert new batteries making sure that the (+) and (-) of   battery are matched correctly.   Slide the cover   upwardly in the   direction of the   arrow.   Re-attach the cover by sliding it back into position.   Exchange the batteries.   Note:   2 3 Use 2 LR03 AAA(1.5volt) batteries. Do not use   rechargeable batteries.Replace batteries with new   ones of the same type when the display becomes dim.   Attention to   the and +   marks.   Storage and Tips for Using the Remote Control   The remote control may be mounted on a wall with   a holder.   Install the cover.   Note: The remote control holder is an optional part.   Remote control holder   F E S L E E E L P C T I M O O E R L O N D T M R A I E Y N R O F F F H E A A H T U T O IG   H M E D L O W S W I N G S L E E P F S L E E E E P L T I M C E R O O N O T L T M I I E R M D O R F F E Y N R F FA   A N A H U T IG   E O A T H H M M E O D S D W I L O E W N G S W I N G O N / S L O F EE   F P T IM   E F A R N M S W O IN   D E G O N / O F F How to Use   To operate the room air conditioner, aim   the remote control to the signal receptor.   The remote control will operate the air   conditioner at a distance of up to 10 feet   when pointing at signal receptor of indoor   unit.   Signal receptor   F E C E L O S L D O L E E R P F Y T I A H N E R E O N A T T M I  R O F F A U H T O S I G L M H E E L E D P O S W W T I N I M G E R M O D E F A N S W I N G O N / O F F 6 Operation Instructions   1 FEEL mode operation procedure   Operates by selecting automatically the operation mode(HEAT,DRY,FAN,COOL)depending on   the room temperature during staring.   With the remote control pointing toward the air conditioner.   Turning on   ON/OFF   Press   button, when the appliance receives the   1 2 signal, the RUN indicator of the indoor unit lights up.   SLEEP TIMER ON TMIER OFF   FEEL   COOL   AUTO   HIGH   MID   LOW   SWING   DRY   FAN   HEAT   When the unit is not at FEEL mode.   Selecting FEEL mode   Press the MODE select button.   SLEEP   TIMER   FAN   Move the MODE to the FEEL position.   SWING   MODE   ON/OFF   Operation mode and temperature are determined by indoor temperature   1 22   3 Indoor temperature   Operation mode   Target temperature   HEATING ( FOR HEAT PUMP TYPE)   FAN (FOR COOL ONLY TYPE)   73 f   Less than 68 f   68 f - 79 f   DRY   64 f   73 f   Over 79 f   COOL   Air temperature adjustment is possible even during FEEL operation.   There are 4 levels of adjustment possible with the button or   the button.   Setting temperature   Press the   button or the   button.   When the button is pushed,the temperature will increase 1 f   After temperature will increase 2 f,the indicator will not change.   When the button is pushed,the temperature will reduce 1 f   After temperature reduce 2 f ,the indicator will not change.   . . The operation of the AUTO   mode can be performed by   only pressing the ON/OFF   button from the next time.   NOTE   There will be a delay when changing mode   is made during the operation.   As there might not be air blown out.   If you don't like the content of FEEL mode operation,   change to HEATING,DRY or COOLING than FEEL.   7 Operation Instructions   1 TIMER mode   It is convenient to set the timer on with TIMER button when you go out in the morning   to achieve a comfortable room temperature when you get home. You can also set   timer off at night to enjoy a good sleep.   When the Remote   When the Remote   Control is ON,press   Control is OFF,press   the TIMER button to set   the TIMER button to   set a switch-on timer,   a switch-on timer,press   press again,the setting   again,the setting will be   will be cancel.   cancel.   Press UP and DOWN button to set time.   Time setting is 30-minutes.   Note: After setting the timer,check that TIMER INDICATOR lamp of   the indoor unit lights.   SLEEP mode   Normal-SLEEP& Comfortable-SLEEP(optional)   1.   Having press the SLEEP button for 3 seconds, SLEEP operation is   switched from Normal-SLEEP to Comfortable-SLEEP alternatively.   Used to set or cancel sleep operation.This function is invalid in fan   and dehumidify mode,This function is invalid in SUPER mode too.   Switches OFF the appliance automatically after 10 hours in Normal-   SLEEP mode.   Normal-SLEEP only   2.   While the unit is running,. Select the operating mode and then press   SLEEP button:the indoor fan speed operates at low speed.Switches   OFF the appliance automatically after 8 hours.   Comfortable-SLEEP note:   In this model,the temperature will automatically be adjusted with the body temperature, like the english   letter   set-temperature decrease together; and at the last stage of sleep, the body temperature will increase   V at the first stage of sleep, the body temperature will decrease when our air-conditioner' s   when our air-conditioner' s set-temperature increase together. It will help you sleep more comfortably.   8 1 Maintenance   Front panel maintenance   Air filter maintenance   It is necessary to clean the air filter after using   it for about 100 hours.   Clean it as follows:   Turn off the appliance   first before disconnecting   from power supply.   Cut off the   power supply   a Stop the appliance   and remove the   air filter.   Grasp position "a"   and pull outward to   remove the front panel.   a 1.Open the front panel.   Wipe with a soft and   dry cloth.   Use lukewarm water(below   104 f) to clean if the   appliance is very dirty.   2.Press the handle of the filter gently   from the front.   3. Grasp the handle and slide out the filter.   Use a dry and   soft cloth to   clean it.   Never use volatile substance   such as gasoline or   polishing powder to clean   the appliance.   Clean and re-install   the air filter.   If the dirt is conspicuous,   wash it with a solution of   detergent in lukewarm water.   After cleaning, dry well in   shade.   Never sprinkle water   onto the indoor unit   Dang   Elec   shoc   k!   erou   tric   s!   Close the front panel again.   b b Clean the air filter every two weeks   if the air conditioner operates in an   extremely dusty environment.   Reinstall and shut the   front panel.   Reinstall and shut the front   panel by pressing position "b" downward.   At the end of the season   At the beginning of the season   Make sure there are no obstacles blocking   the airflow around the air intake and air   outlet openings of the Indoor and Outdoor   Units   Set temperature to 86 f for about half a day   and perform the Cooling operation to dry   well the Unit's inside.   Dry the inside   of the unit.   Stop the unit operation and then   turn off the power switch for safety   Check the installation base for corrosion or rust.   ON   and for saving electric energy.   OFF   Make sure the earth   wire is not broken or   disconnected   Clean and reinstall the air filters.   Make sure the air filters are cleaned.   Clean both Indoor and Outdoor Units.   Turn on the power switch.   Remove batteries from the remote control .   Insert batteries into the remote controller.   9 1 Protection   Operating condition   Noise pollution   The protective device maybe trip and stop   the appliance in the cases listed below.   Install the air conditioner at a place that   can bear its weight in order to operate   more quietly.   Outdoor air temperature is over 75 f   HEATING   Outdoor air temperature is below -19 f   (-5 f for inverter models,it's optional)   Install the outdoor unit at a place where   the air discharged and the operation noise   would not annoy your neighbors.   Room temperature is over 80 f   Outdoor air temperature is over *110 f   (or below 32 f for inverter models)   COOLING   Room temperature is below 69 f   Do not place any obstacles in front of the   air outlet of the outdoor unit as it will increase   the noise level and possible malfunction   of fan motor.   Room temperature is below 64 f   DRY   * For Tropical (T3) Climate condition models, the   temperature point is 96 f instead of 96 f.   If the air conditioner runs in COOLING or DRY mode with   door or window opened for a long time when relative   humidity is above 80%,dew may drip down from the outlet.   Features of protector   Inspection   The protective device will work as follows.   After using for long time, the air conditioner   should be inspected on the following items.   Restarting the unit at once after operation   stops or changing mode during operation, you   need to wait 3 minutes.   Overheat of the power supply cord and plug   or even a burned smell.   Abnormal operating sound or vibration.   Water leakage from indoor unit.   Metal cabinet electrified.   Connect to power supply and turn on   the unit at once, it may start 20 seconds   later.   Stop the air conditioner if above trouble occurs.   It is advisable to have a detail inspection after   using it for 5 years even if none above occurs.   If all operation has stopped, press ON/OFF   button again to restart.   Timer should be set again if it has been   canceled.   Features of HEATING mode   Preheat   At the beginning of HEATING operation, the airflow from indoor unit is discharged 2-5   minutes later.   Afterheat   After the finishing of HEATING operation, the airflow from indoor unit is discharged 2-5   minutes.   Defrost   In HEATING operation the appliance will defrost (de-ice) automatically to raise efficiency.   This procedure usually lasts 2-10 minutes. During defrosting, fans stop operation.   After defrosting completes, it returns to HEATING mode automatically.   Note: Heating is NOT available for cooling only air conditioner models.   10   1 Troubleshooting   The following cases may not always be a malfunction, please check it before asking for service.   Analysis   If the plug is not properly plugged.   Trouble   If batteries in the remote controller exhausted.   If the protective device works to protect the appliance.   If the protector trip or fuse is blown.   Does not run   Are the intakes and outlets of the air conditioner   blocked   Is the temperature set properly   No cooling or   heating air   Is the air filter dirty?   If strong interference(from excessive static electricity   discharge, power supply voltage abnormality)presents,   operation will be abnormal. At this time, disconnect   from the power supply and connect back 2-3 seconds later.   Ineffective control   Does not operate   immediately   Changing mode during operation, 3 minutes   will delay.   don't run   This odor may come from another source   such as furniture, cigarette etc, which is   sucked in the unit and blows out with the air.   Peculiar odor   Caused by the flow of refrigerant in the   air conditioner, not a problem.   Defrosting sound in heating mode.   A sound of   flowing water   The sound may be generated by the expansion   or contraction of the front panel due to change   of temperature.   Cracking sound is   heard   Mist appears when the room air becomes   very cold because of cool air discharged   from indoor unit during COOLING or DRY   operation mode.   Spray mist from   the outlet   The unit is shifting from heating mode to defrost.   The indicator will lights go off within ten minutes   and returns to heating mode.   The compressor indicator(red) lights on   constantly,and indoor fan stops.   Air will not   immediately   blow out at the start of HEAT mode   The air conditioner is ready to blow out enough warm   air please wait(2~5 minutes )   The appliance will defrost automatically ,and mist   appears from outdoor.After defrosting ,it continues to   run automatically.   Stop   discharging   airflow for 5~10minutes   during HEATING operation   Don't   discharge   check the distance between the remote controller   and the unit.   Are the batteries exhausted? Replace them with new   ones,and repeat the operation again.   The remote   control   does not function correctly   11   1 Installation Instructions   Installation Diagram   Distance from ceiling   should be over 6   Distance from wall   should be over 6   Distance from the wall   should be over 6   Distance from floor   should be over 6 feet   over 20   Air intake distance from the wall   Should be over 12   Air intake distance from   the wall should be   over 12   over 12   NOTE   Above figure is only a simple presentation   of the unit, it may not match the external   appearance of the unit you purchased.   Installation must be performed in accordance with   the national wiring standards by authorized personnel only.   Very Important-Installation must done by a registered   qualified installer.(Refer warranty section at the back of this manual)   12   Installation Instructions   1 Front panel   Connecting of the Cabb   le   Wiring between the indoor and outdoor units:   Terminal (inside)   1) Remove the PCB cover from the indoor unit;   2) Refer to the wiring diagram attached to indoor unit   when connecting cords to indoor unit terminals;   3) Reinstall the PCB cover. Be sure that side B   is facing outside.   COVER   COVER   A side (before connect)   B side (after connect)   Cabinet   Select the best location   Location for Installing Indoor Unit   Installation Diagram   Where there is no obstacle near the air outlet and air can be   easily blown to every corner.   Indoor unit   Where piping and wall hole can be easily arranged.   Keep the required space from the unit to the ceiling and wall   according to the wiring diagram.   Where the air filter can be easily removed.   Keep the unit and remote control 3 feet or more apart from   television, radio etc.   Pipe length is   49 feet Max.   Outdoor unit   Keep as far as possible away from fluorescent lamps.   Do not put anything near the air inlet to obstruct it from air   absorption.   Where there is bearing wall to handle weight and decrease   vibration and noise.   Location for Installing Outdoor Unit   Outdoor unit   Where it is convenient to install and well ventilated; avoid   installing it where flammable gas could leak.   Keep the required distance apart from the wall.   Keep the outdoor unit away from a place of greasy dirt,   vulcanization gas exit or high salty seashore.   Avoid installing it at the roadside where there is a risk of   muddy water.   Pipe length is   49feet Max.   A fixed base so as not to increasing operation noise.   Where there is no blockage for air outlet.   Indoor unit   13   1 Installation Instructions   Indoor Unit Installation   1. Installing the Mounting Plate   Decide an installing location for the mounting plate according to the indoor unit location and piping direction.   Keep the mounting. plate horizontally with a horizontal ruler or dropping line.   Drill holes of 1" in depth on the wall for fixing the plate.   Insert the plastic plugs to the hole, fix the mounting plate with tapping screws.   Inspect if the mounting plate is well fixed. Then drill a hole for piping.   Line drops from here   Hook the line here   Mounting plate   Dropping line   holes for fixing   Note: The shape of your mounting plate may be different from the one above, but installation method is similar.   2. Drill a Hole for Piping   r o Wall hole sleeve   ( hard polythene tube   prepared by user)   o Decide the position of hole for piping according to the   location of mounting plate.   d t u O Drill a hole on the wall. The hole should tilt a little   downward toward outside.   1/4 "   (tilt downward)   Install a sleeve through the wall hole to keep the wall   tidy and clean.   3. Indoor Unit Piping Installation   Put the piping (liquid and suction pipe) and cables through the wall hole from outside or put them through   from inside after indoor piping and cables connection complete so as to connect to outdoor unit.   Decide whether saw the unloading piece off in accordance with the piping direction.(as shown below)   Piping direction   trough   Unloading   piece   4 1 3 Note: When installing the pipe at the directions   1,2 or 4, saw the corresponding unloading piece   off the indoor unit base.   Saw the unloading piece   off along the trough   2 After connecting piping as required, install the drain hose. Then connect the power cords. After connecting,   wrap the piping, cords and drain hose together with thermal insulation materials.   14   1 Installation Instructions   NOTE   Piping Joints Thermal Insulation:   Wrap the piping joints with thermal   insulation materials and then wrap   with a vinyl tape.   wrapped with vinyl type   The temperature of refrigerant circuit   will be high, please keep the   Thermal insulation   interconnection cable away from the copper tube.   Piping Thermal Insulation:   Large pipe   Thermal insulation   tube   a. Place the drain hose under the piping.   b. Insulation material uses polythene foam over 3/8" in thickness.   Note: Drain hose is prepared by user.   Power cord   Small   pipe   Drain pipe should point downward for easy drain flow.   Do not arrange the drain pipe twisted, sticking out or wave   around, do not immerse the end of it in water.   Power cord 1   (for heat-pump)   If an extension drain hose is connected to the drain pipe, make   sure to thermal insulated when passing along the indoor unit.   Drain hose   (prepared by user)   Defrost cable(for heat-pump)   Insert here   When the piping is directed to the right, piping, power   Cord and drain pipe should be thermal insulated and   fixed onto the back of the unit with a piping connector.   large   pipe   large   pipe   drain   hose   drain   small   hose   pipe   small   pipe   Hook here   Piping fixer   Base   Piping connector   Base   Base   A. Insert the pipe connector to the slot.   B. Press to hook the pipe connector onto the base.   Connecting the refrigerant lines between the indoor& outdoor units   Note that since the refrigerant metering device is located in the outdoor unit,both refrigerant   lines must be insulated with a minimum of 3/8" foam along the entire length.   Gently bend the line set stubs from the indoor unit to the desired location and the using 2 box   end or adjustable wrenches,remove the flare nuts from the indoor unit line stubs.The indoor   unit is charged with a dry gas.If you do not hear the release of pressure when removing the   flare nuts,it is possible that the evaporator section(indoor unit)has developed a leak and you   should contact your dealer for a replacement indoor unit.Note:Using a small amount of   vacuum pump oil on the male flare threads will ease installation.Snug the line set to the stubs   using the 2 wrenches-one wrench on the male fitting and one wrench on the female fitting.   Tighten flares tobelow torques:   Refrigerant Line Connection Torque Table   Flare Nut   1/4-3/8"   Tightening Torque   25 Ft.LBs(350 Kg.Cm)   40 Ft.LBs(560 Kg.Cm)   60 Ft.LBs(840 Kg.Cm)   110 Ft.LBs(1540Kg.Cm)   1/4-1/2"   1/2-3/4"   7/8-1 1/8"   15   1 Installation Instructions   4. Connecting of the Cable   Indoor Unit   Front panel   Connect the power connecting cord to the indoor unit   by connecting the wires to the terminals on the control   board individually in accordance with the outdoor unit   connection.   Terminal (inside)   Cabinet   Note: For some models, it is necessary to remove the cabinet to   connect to indoor unit terminal.   Indoor unit   Chassis   Outdoor Unit   1). Remove the access door from the unit by loosening   the screw. Connect the wires to the terminals on the   control board individually as the following.   2). Secure the power connecting cord onto the control   board with cable clamp.   Access door   Terminal(inside)   3). Reinstall the access door to the original position   with the screw.   4) Use a recognized circuit breaker for 24K.30K model   between the power source and the unit. A disconnecting   device to adequately disconnect all supply lines must be   fitted.   Outdoor unit   The figures in this manual are based on the external view of a standard model.   Consequently, the shape may differ from that of the air conditioner you have selected.   Caution:   1. Never fail to have an individual power circuit specifically for the air conditioner. As for the   method of wiring, refer to the circuit diagram posted on the inside of the access door .   2.Comfirm that the cable thickness is as specified in the power source specification.   (See the cable specification table below)   3.Check the wires and make sure that they are all tightly fastened after cable connection.   4. Be sure to install an earth leakage circuit breaker in wet or moist area.   Wire Gauge Requirements   Wire Gauge atDifferent Wire Lengths   Circuit   Amp   200ft   50ft   150ft   100ft   15   20   25   30   35   40   45   50   8 6 6 4 4 4 3 3 10   8 14   12   10   6 4 4 4 3 3 2 8 6 6 10   8 8 6 4 6 2 4 6 (Nec,105c/221 F Type Copper Conductors)   16   Installation Instructions   1 Outdoor Unit Installation   1.Install Drain Port and Drain Hose (for heat-pump model only)   The condensate drains from the outdoor unit when the unit operates   in heating mode. In order to protect the environment, install a drain   port and a drain hose to direct the condensate water. Just install the   drain port and rubber washer to the chassis of the outdoor unit, then   connect a drain hose to the port as the right figure shown.   Washer   Drain hose   (prepare by user)   Drain port   2. Install and Fix Outdoor Unit   Fix with bolts and nuts tightly on a flat and strong floor.   If installed on the wall or roof, make sure to fix the supporter well to prevent it   from shaking due to serious vibration or strong wind.   3. Outdoor Unit Piping Connection   Remove the valve caps from the 2-way and 3-way valve.   Connect the pipes to the 2-way and 3-way valves separately according to the required torque.   4. Outdoor Unit Cable Connection (see previous page)   Air Purging   The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the   compressor. After connecting the indoor and outdoor units, evacuate air and moisture from refrigerant   cycle using a vacuum pump, as shown below.   Vacuum pump   Indoor unit   Refrigerant flow direction   2-way valve   3-way valve diagram   3-way valve   connect to indoor unit   (6) Open 1/4 turn   (7) Turn to fully open the valve   valve cap   open position   spindle   (7) Turn to fully open the   valve   Service   port   (1) Turn   (8) Tighten   (1) Turn   (2) Turn   (8) Tighten   Valve cap   needle   (8) Tighten   Connect to outdoor unit   Valve core   service port cap   Note: To protect the environment, be sure not to discharge the refrigerant to the air directly.   17   Installation Instructions   Interconnection Cable   1 (1)Take off the cover for Interconnection cable of outdoor unit.   (2)Take off the block for Interconnection cable, then put the core of the power wire to the terminal and   fix it according to the diagrams pasted to indoor and outdoor unit separately.   (3)Fix the accessory cable with the Interconnection cable block.   (4) Confirm the fixing of the accessory cable is ok.   (5)Fix the cover for Interconnection cable on.   Diagram for installation of Interconnection cable   ( please see the pasted diagram instruction on the body first)   Circuit Diagram   12K 18K 24K indoor and outdoor interconnection cable sketch map   Indoor Unit   Outdoor Unit   L W L   W L   W Connetting   outdoor unit   Connetting   power   Connetting   indoor unit   Cooling & Heating   Note: Some models are designed without the conneting terminal in indoor unit,please subject   to the connetion diagram of the product.   18   1 Installation Instructions   How to Purge Air Tubes   (1). Unscrew and remove caps from 2 and 3-way valves.   (2). Unscrew and remove cap from service valve.   (3). Connect vacuum pump flexible hose to the service valve.   (4). Start vacuum pump for 10-15 minutes until reaching a vacuum of 30" Hg absolutes.   (5). With vacuum pump still running close the low pressure knob on vacuum pump manifold. Then stop   vacuum pump.   (6). Open 2-way valve 1/4 turn then close it after 10 seconds. Check tightness of all joints using liquid   soap or an electronic leak detector.   (7). Turn 2 and 3-way valves stem to fully the valves. Disconnect vacuum pump flexible hose.   (8). Replace and tighten all valve caps.   Test Running   Connect to the power source, check if the function selection keys on the remote controller are working   properly.   Check if the room temperature adjustments and timer settings are working properly.   Check if the drain is open.   Check if there is any abnormal noise or vibration during operation.   Check if there is leakage of refrigerant.   ATTENTION:   If there is no power plug along with the air conditioner,The power cord should be connected to an air   switch ,whose current carrying capacity should be more than 20A and the minimum open-circuit   distance among the live polar pole,the neutral polar pole and the ground polar pole should be more   than 1".If any malfuctions,please cut off the supply by the air switch and contact the manufacturer   or its service agent.   The appliance shall be installed in accordance with national wiring regulations.   If the supply cord is damaged. It is better to be replaced by the manufacturer or its service agent or a   similarly qualified person in order to avoid a hazard.   NOTE   Please read this manual before installing and using it.   Do not let air enter the refrigeration system or discharge refrigerant when moving the air conditioner.   Test run the air conditioner after finishing installation, and record details of operation.   Type of fuse used on indoor unit controller for 7K,9K,12K 15K,16K,18K, 22K,24K,30K is 50T with   rating 3.15 A,250V;Type of fuse used on inverter outdoor unit controller for 7K,9K,12K is 61T with   rating 15 A,250V,for 18K,22K,24K is 65TS with rating 25A,250V.   The fuse for the whole unit is to be provided by the user according to the current at maximum power   input or use other over-current protective device instead.   Accessibility to the plug must be guaranteed even after the installation of the appliance to disconnect   it in case of need. If not possible, connect appliance to a double-pole switching device with contact   separation of at least 1 " placed in an accessible position even after installation.   Please make replacing with the special assembly purchasing from our factory or our   service center if something wrong with Interconnection cable.   The security out static air pressure for our products is 0.8-1.05 * standard pressure.   The biggest length for our connection pipe can be 49 feet. More refrigerant is   necessary for per foot if the length is over 21 feet.   Please do not place valuable things under the unit after installation.   19   Model:KFTHP-12-ID   Model:KFTHP-12-OD   Model:KFTHP-18-ID   Model:KFTHP-18-OD   Model:KFTHP-24-ID   Model:KFTHP-24-OD   |