| GM-PAC-12E1   GM-PAC-12E1HP (WITH HEAT)   12,000 BTU Portable Air   Conditioner   PACKAGE CONTENTS   Portable Air Conditioner   Exhaust Hose (1)   Front Exhaust Hose Adapter (1)   Window Kit Adapter (1)   Rear Exhaust Hose Adapter (1)   Remote Control & AAA Batteries (2 batteries)   Window Kit - 3 Sliding Panels (1 single hose panel, 2 extension panels)   Owner’s Manual   SPECIFICATIONS   • • • • • The cooling capacity is measured at an ambient temperature of DB 86 °F, WB 78 °F.   Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode.   Power consumption is measured when the fan runs at the highest speed setting.   These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.   If the environment temperature is higher than the max operating temperature or lower than the minimum operating   temperature, the air conditioner may not work properly.   • • Dehumidifier mode works when ambient temperatures are between 61°F - 86°F   Air Conditioner mode operates up to an ambient temperature of 95°F.   Model   GM-PAC-12E1   GM-PAC-12E1HP (with Heat)   Power Supply (Ph/V/Hz)   1/115/60Hz   1/115/60Hz   Dehumidifying Capacity (Pints/Day)   Rated Cooling Capacity (BTU/h)   Rated Heating Capacity (BTU/h)   Cooling Power Input (Watts)   Heating Power Input (Watts)   Rated Current Cooling (Amperage)   Rated Current Heating (Amperage)   Noise Level (dBA) - H/M/L   Air Flow - H/M/L (CFM)   81   81   12,000   12,000   - 10,500   1465   1465   - 1200   13   13   10.6   - 55/53/51   55/53/51   235/205/175   17.75 x 33.125 x 17.125   80   235/205/175   17.75 x 33.125 x 17.125   80   Product Dimensions (W” x H” x D”)   Product Weight (Lbs)   Refrigerant Type   R-410A   R-410A   3 LCDI POWER CORD AND PLUG   This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and   plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord   with no termination on the load side and a LCDI attachment plug on the line side.   The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the   nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.   The cord will remain de-energized until the devise has been manually reset. This is intended to reduce the risk   of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must   be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed   metal.   The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:   1. Plug power cord into wall outlet   2. Press TEST Button, circuit should trip, cutting power to the air conditioner   3. Press RESET button for use   If a test is performed and the indicator light remains ON, current leakage has been detected. Do not use the air   conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Powered by Gree Customer Service for trou-   bleshooting recommendations.   RESET   TEST   WARNING:   1. DO NOT press the TEST button while the air conditioner is operating.   2. The TEST and RESET buttons should not be used as “ON” and “OFF” switches.   3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.   4. The cord and plug are intended for indoor use only.   4 PRODUCT DIAGRAM   Air Outlet &   Louvers   Carry Handle   Control Panel   Filter   Upper Air Intake   Location   Air Exhaust Vent   Lower Air Intake   Power Cord   5 PARTS & WINDOW KIT ASSEMBLY   PARTS   EXHAUST HOSE & ADAPTERS   Front Exhaust Hose   Adapter   Rear Exhaust Hose   Exhaust Hose   Adapter   Window Kit Adapter   Sliding Panels (3)   ASSEMBLY & INSTALLATION   INSTALLATION   When the unit is operating as an air conditioner or dehumidifier, the window kit and exhaust hose must be installed.   When the unit is operating in fan mode, the window kit and exhaust hose do not need to be installed .   MOUNTING THE EXHAUST HOSE   • Choose a suitable location, near a grounded electrical outlet and suitable window or door. Remove   packaging and locate components.   • • Extend both ends of the exhaust hose approximately 6 inches.   Screw the REAR and FRONT Exhaust Hose Adapters onto each end of the exhaust hose. Once both   adapters are attached, attach the Window Kit Adapter to the REAR Exhaust Hose Adapter.   • • • Connect the FRONT Exhaust Hose Adapter to the back of your portable air conditioner.   Attach the Window Kit Adapter to the window kit.   For maximum efficiency bend the exhaust hose as little as possible once installation is complete.   6 SINGLE HOSE WINDOW KIT INSTALLATION   This installation is OK   The is a poor installation   22”   When installing the exhaust hose, try and keep it as flat as possible. The less angles and bends   in the hose, the better the unit will perform. If bending or an angle is necessary, use single 90°   angles like the pictures above. Multiple bends will decrease performance and efficiency   7 CONTROL PANEL   GM-PAC-12E1   COOL MODE LIGHT DRY MODE LIGHT   LED DISPLAY   FAN MODE LIGHT   BUCKET FULL LIGHT   POWER BUTTON   MODE BUTTON   TEMP SELECT BUTTONS   GM-PAC-12E1HP   HEAT MODE LIGHT DRY MODE LIGHT   LED DISPLAY   FAN MODE LIGHT   COOL MODE LIGHT   POWER BUTTON   MODE BUTTON   TEMP SELECT BUTTONS   8 CONTROL PANEL FUNCTIONS   CONTROL PANEL OPERATING INSTRUCTIONS   1) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER   button once more to turn the unit off.   2) Mode Selection - Press the MODE Button repeatedly to cycle between the different modes:   Air Conditioner, Dehumidifier (DRY), Fan only, and Heater mode (NOTE: Heater mode is only available   on the GM-PAC-12E1HP). Each press of the MODE button will light up a different mode icon on the con-   trol panel. The exhaust hose and window kit must be installed when the unit is in Air Conditioner,   Dehumidifier (DRY), or Heater (GM-PAC-12E1HP only) mode. When using the unit as a fan, it is not   necessary to keep the exhaust hose and window kit connected to the unit.   3) Temperature - Select the desired temperature by pressing either ▼ or ▲ key when using the unit in   Cooling or Heating (GM-PAC-12E1HP only) mode. The digital thermostat will display the set temperature.   4) Bucket Full - When the unit cannot evaporate the collected moisture fast enough, the excess water will   collect in a backup water tank located inside the unit. The Bucket Full icon (GM-PAC-12E1) or Heat Mode   icon (GM-PAC-12E1HP) will light up if this occurs. The unit will then beep 8 times and the LED display   will show “H8”. The compressor will now shut off. You should now drain the excess water from the unit.   To do this, get a small pan and place it under the drain plug on the bottom of the back of the unit. Remove   the plug and slightly tilt the unit backwards to drain the water into the pan.   9 REMOTE CONTROL OPERATING INSTRUCTIONS   - / +   - / + BUTTONS   SIGNAL TRANSMITTER   When the unit is in Air Conditioner or Heater (GM-PAC-   12E1HP) mode you can select your desired temperature.   Press the TEMP SELECT buttons (+ or -) to select   your desired temperature setting. The temperature on the   LCD display on the remote control will increase or de-   crease accordingly. Hold the +/- buttons for two seconds   to rapidly increase or decrease the temperature. Temp.   range is 61°F—86°F.   FAN   FAN BUTTON   Press the Fan Speed button to change fan speeds.   Fan Speeds:   REMOTE CONTROL   Low Speed   High Speed   Medium Speed   NOTE: When the unit is in Dehumidifier (DRY) mode,   the fan speed is not adjustable.   TEMP BUTTON   ON/OFF   ON/OFF BUTTON   Press the Up and Down Swing Button to turn on and off   the vertical swing mode. In vertical swing mode, the lou-   vers will rotate up and down to circulate more air.   Press the ON/OFF (POWER) button once to manually   turn the unit on. Press the Power button once more to   turn the unit off.   When the unit is off, press the Up and Down Swing But-   ton and “+” at the same time to enable stationary swing   mode. Stationary Swing mode allows for more control   over the way the louvers swing up and down. The Swing   icon on the Remote LCD will blink twice when this is   MODE   MODE BUTTON   Press the MODE Button repeatedly to cycle between the   different modes.   Blinks for 2 Seconds   In Stationary Swing mode, press the Up and Down   Swing Button to change the swing pattern per below:   AUTO   COOL   DRY   Disable Stationary Swing Mode by pressing the Up and   Down Swing Button and “+” button at the same time.   The Swing Icon on the Remote LCD will blink twice   when this is disabled.   FAN   NOTE: Heat Mode is only   available on GM-PAC-12E1HP   HEAT   10   REMOTE CONTROL OPERATING INSTRUCTIONS   TIMER   TIMER BUTTON   Auto-on Timer: When the air conditioner is off, it can   be set to automatically turn on in 30 minutes to 24 hours   at the previous set mode and fan setting. To set the Auto-   on Timer, press the TIMER button on the unit or remote   control. Each touch of the +/- buttons on the remote will   change the timer setting in 30 minute increments (.5   hours). HOUR ON/OFF icon will blink when the Auto-   on Timer is being set. Once the timer is set, press the   TIMER button once more to save the setting.   Auto-off Timer: When the air conditioner is on, it can   be set to automatically turn off in 30 minutes to 24 hours.   To set the Auto-off Timer, press the TIMER button on   the remote control. Each touch of the +/- buttons on the   remote will change the timer setting in 30 minute (.5   hour) intervals. HOUR ON/OFF icon will blink when the   Auto-off Timer is being set. To cancel the timer, press   the ON/OFF button. Once the timer is set, press the   TIMER button once more to save the setting. Press the   ON/OFF button to clear a time setting.   REMOTE CONTROL   HEALTH|SAVE   HEALTH|SAVE BUTTON   HORIZONTAL SWING BUTTON   The Health Function is not available on this unit.   This function is not available on this unit.   Press the Save button to automatically rotate through   the different speeds. To disable Save mode and pick   your own fan speed, press the Save button again.   TURBO   TURBO BUTTON   This function is not available on this unit.   TEMP   TEMP BUTTON   Press the TEMP button to display the current set tem-   perature or the actual room temperature. With each   press of the TEMP button the display will cycle back   and forth.   11   REMOTE CONTROL OPERATING INSTRUCTIONS   X-FAN   X-FAN BUTTON   REMOTE CONTROL   Press the X-FAN button to enable the X-Fan function.   When enable, X-Fan will force the fan to remain on once   the unit is powered down. The fan stays on to dry out any   remaining moisture in the unit to help minimize mold or   bacteria growth. X-Fan cannot be set under Auto, Fan, or   Heat (GM-PAC-12E1HP only) modes.   LOCK   LOCK FUNCTION   • Press “+” and “-” buttons together at the same time to   lock the remote keyboard. Do this again to unlock.   SLEEP   SLEEP BUTTON   LIGHT   LIGHT BUTTON   Press the SLEEP mode button to engage SLEEP   mode.. This feature limits compressor usage and   enhances energy savings by adjusting the set   temperature while you are sleeping. Press the SLEEP   button once more to disable Sleep Mode. Sleep Mode   is not available in Auto or Fan Modes.   Press the LIGHT button to turn the on the display Light.   A small Light bulb icon will light up on the remote con-   trol display.   AUTO   AUTO MODE   In Cooling or Dehumidifier (DRY) modes: When sleep   mode is selected the set temperature will automatically   increase 2°F after 1 hour. After 2 hours, the set tempera-   ture will increase another 2°F for a total increase of 4°F.   • Press the MODE button to select Auto Mode. Once   Auto Mode is selected the unit will automatically   choose the operating mode based on the current room   temperature. The temperature will not be displayed on   the LED in this mode.   TEMP   MEASURE   CHANGE BETWEEN F° and C°   In Heating mode (GM-PAC-12E1HP only): When sleep   mode is selected the set temperature will automatically   decrease 2°F after 1 hour. After 2 hours, the set tem-   perature will decrease another 2°F for a total decrease of   4°F.   • When the unit is off, press the MODE and “-” button   to change between F° and C°.   12   MAINTENANCE   Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to   performing any maintenance on the unit.   Clean or replace filter - If the air filter is blocked with a dust, the airflow volume may decrease. It is   recommended to clean the filter once every two weeks, or as needed.   1) Remove the filter from the filter compartment on the back of the unit.   2) Wash the air filter by immersing it gently into warm water with a neutral detergent. Rinse the filter   and dry it thoroughly out of sunlight.   3) Slide the filter back into the filter compartment after it is thoroughly dried.   4) If the filter is torn or unusable, order a new filter by calling the customer service number on the   warranty page of this manual.   Clean the unit Housing   1) Keep the unit from being exposed directly to the sun to prevent color fading.   2) Clean the surface with a damp cloth and dry it with a soft towel.   Storing the Unit for an Extended Period of Time or Transporting the unit   1) Empty any excess water by unplugging the water drainage stop in the back of the unit (located at   the bottom).   2) Unplug the unit.   3) The unit should be stored in a cool dry place.   DISCLAIMER   ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL ARE THE   PRESENTATION OF THE MANUFACTURER. SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT   TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN.   13   TROUBLESHOOTING   PROBLEM   POSSIBLE CAUSES   SOLUTIONS   The Air Conditioner will not start   The air conditioner is unplugged or not   connected well.   • Make sure the air conditioner plug   is pushed completely into the out-   let   • Check the house fuse/circuit   breaker box and replace the fuse   or reset the breaker.   The fuse is blown/circuit breaker is   tripped.   • • The unit will automatically re-start   when power is restored.   There is a protective time delay   (approx. 3 minutes) to prevent   tripping of the compressor   Power Failure   overload. For this reason, the unit   may not start normal cooling for 3   minutes after it is turned back on.   • • Press the RESET button located   on the power cord plug.   If the RESET button will not stay   engaged, discontinue use of the   air conditioner and contact a   qualified service technician.   The current interrupter device is   tripped.   The Air Conditioner does not cool   as it should   Airflow is restricted   • Make sure there are no curtains,   blinds, or furniture blocking the   front of the air conditioner   • • • Lower the set thermostat tempera-   ture   The temperature control may not be   set correctly.   The air filter is dirty   Clean the filter. See the Cleaning   and Care Section of the manual.   Please allow time for the room to   cool down after turning on the air   conditioner.   The room may be too warm   • • • Check for open furnace registers   and cold air returns   Cold air is escaping   The Evaporator is frozen   The unit is defrosting and will re-   sume operation when done.   The Dehumidifier function is not   providing cool air as it should   The Air Conditioner displays the   Timer hours but does not work   Is the TIMER ON enabled?   Cancel the TIMER or wait until the   unit turns on.   The Remote Control is not working The batteries are inserted incorrectly   • • Check the position of the batteries.   Replace the batteries   The batteries may be dead   14   TROUBLESHOOTING (CONT.)   PROBLEM   POSSIBLE CAUSES   SOLUTIONS   The LCD Display is showing “E5”   Low Voltage Protection   • Unplug for 10 minutes and then   turn on the unit. If “E5” is still dis-   played, contact customer service.   The LCD Display is showing “H8”   The backup water tank is full   • • Drain the water tank   If the “H8” I still displayed after the   water tank has been emptied, con-   tact customer service.   The LCD Display is showing “F1”,   “F2”, or “F4”   Internal malfunction   • Contact Customer Service   15   WARRANTY   One Year Limited Warranty   Soleus International Inc. warrants the accompanying Soleus Air Powered by Gree Portable Air Conditioner to be free of   defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1)   year from the date of original retail purchase in the United States.   If the unit exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it, free of   charge within a reasonable time after the unit is returned during the warranty period.   As a condition to any warranty service obligation, the consumer must present this Warranty Certificate along with a   copy of the original purchase invoice.   THIS WARRANTY DOES NOT COVER:   • Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a defect in   material or workmanship.   • Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions   in the instructions.   • • Damage to the finish of the case, or other appearance parts caused by wear.   Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna-   tional Inc.   • Freight and Insurance cost for the warranty service.   ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO   ONE-YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY. SOLEUS INTERNATIONAL INC.   DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT   SHALL SOLEUS INTERNATIONAL INC’S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR   BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT.   This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover used, sal-   vaged, or refurbished products.   As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow   limitation on implied warranties, the above limitations and exclusions may not apply to you. This warranty gives you   specific legal rights, and you may also have other rights that vary from state to state.   For Technical Support & Warranty Service   Please Call (888) 876-5387   Or Write To:   Soleus International Inc.   20035 E. Walnut Dr, North.   City of Industry, CA 91789 USA   16   |