| OWNER’S INSTRUCTIONS   MANUAL DE INSTRUCCIONES   MANUEL D’UTILISATION   ISTRUZIONI PER L’USO   MANUAL DE INSTRUÇÕES   GEBRAUCHSANWEISUNG   O¢H°IE™   Indoor unit   AS07S8GB   AS07S8GE   AS07SBGE   AS09S8GB   AS09S8GE   AS09SBGE   AS12SBGE   AS12SGGB   AS12SGGE   AS14SGGB   AS18S0GB   AS18S0GE   AS24S6GB   AST24S6GE   Outdoor unit   US07S8GB   US07S8GE   US07SBGE   US09S8GB   US09S8GE   US09SBGE   US12SBGE   US12SGGB   US12SGGE   US14SGGB   US18S0GB   US18S0GE   US24S6GB   UST24S6GE   Split-type Room Air Conditioner (Cool)   Aire acondicionado doméstico sistema Split (Refrigeración)   Climatiseur de type Séparé (Refroidissement)   Condizionatore d’aria per ambienti ad unità Separate (Raffreddamento)   Aparelho de ar condicionado tipo Split (Refrigeração)   Geteilte raumklimaanlage (Kühlen)   ¢IAIPOYMENO K§IMATI™TIKO ¢øMATIOY(æ‡Í˘)   E S F I P D G DB98-08801A(4)   Contents   ◆ ◆ PREPARING YOUR AIR CONDITIONER   ◆◆◆Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   ◆◆◆View of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   ◆◆◆Remote Control-Buttons and Display . . . . . . . . . . . . . . . . . . . . . .   ◆◆◆Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   ◆◆◆Inserting the Remote Control Batteries . . . . . . . . . . . . . . . . . . . . .   2 4 6 7 8 OPERATING YOUR AIR CONDITIONER   ◆◆◆Selecting the Automatic Operating Mode . . . . . . . . . . . . . . . . . . .   9 ◆◆◆Cooling Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10   ◆◆◆Changing the Room Temperature Quickly . . . . . . . . . . . . . . . . . . 11   ◆◆◆Removing Excess Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12   ◆◆◆Airing Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13   ◆◆◆Selecting Energy Saving Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 14   ◆◆◆Adjusting the Air Flow Direction Vertically . . . . . . . . . . . . . . . . . . . 15   ◆◆◆Adjusting the Air Flow Direction Horizontally . . . . . . . . . . . . . . . . 15   ◆ ◆ PROGRAMMING YOUR AIR CONDITIONER   ◆◆◆Setting the On Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16   ◆◆◆Setting the Off Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17   ◆◆◆Setting the Sleep Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18   RECOMMENDATIONS FOR USE   ◆◆◆Operating Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19   ◆◆◆Temperature and Humidity Ranges . . . . . . . . . . . . . . . . . . . . . . . . 19   ◆◆◆Operating Your Air Conditioner Without the Remote Control . . . . . 20   ◆◆◆Solving Common Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21   ◆◆◆Cleaning Your Air Conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22   ◆◆◆Cleaning Deodorizing and Bio-Green filters (option) . . . . . . . . . . . 22   ◆ TECHNICAL SPECIFICATIONS   E-3   View of the Unit   The design and shape are subject to change according to the model.   Indoor Unit   On/Off switch   Air filter   (under the grille)   Air Inlet   Remote Control Sensor   Air flow blades   (outlet)   TURBO indicator (RED)   Energy Saving indicator   (GREEN)   Operation indicator   (GREEN)   Timer indicator   (YELLOW)   E-4   Outdoor Unit   US07S8GB   Air Outlet   US07S8GE   US09S8GB   US09S8GE   Air Inlet(Rear)   SH30ZC1(C2)X   Connection Valve   (inside)   Outdoor Unit   Outdoor Unit   Outdoor Unit   US07SBGE   Air Outlet   US09SBGE   Air Inlet(Rear)   US12SBGE   Connection Valve   US12SGGB US12SGGE US14SGGB   Air Inlet(Rear)   Air Outlet   Connection Valve   (inside)   US18S0GB   US18S0GE   US24S6GB   UST24S6GE   Air Inlet(Rear)   Air Outlet   Connection Valve   E-5   Remote Control - Buttons and Display   Remote control   transmission indicator   Mode selection button   (AUTO, COOL, DRY, FAN)   Operating mode   ( AUTO,   COOL,   DRY,   FAN)   Temperature adjustment   buttons   Temperature setting   Turbo mode   Sleep mode   Turbo/Sleep mode   selection button   Energy saving   Fan speed   Fan speed adjustment button   Swing button   Air flow direction   On Timer setting   On Timer button   Off Timer button   Off Timer setting   Battery discharge indicator   On/Off &   Timer Set/Cancel button   Energy Saving button   E-6   Getting Started   You have just purchased a split type air conditioner and it has been   installed by your installation specialist.   Your Owner’s Instructions contains valuable information on using your   air conditioner. Please take the time to read it as it will help you take full   advantage of the unit’s features.   The booklet is organized as follows.   ◆ The following figures are shown on pages from 4 to 6 :   - - Indoor and outdoor units   Remote control(buttons and display)   They will help you find the buttons and understand the symbols displayed.   ◆ In the manual, you will find a series of step-by-step procedures for each   function available.   The illustrations in the step-by-step procedures use three different symbols:   PRESS   PUSH   HOLD DOWN   E-7   Inserting the Remote Control Batteries   You must insert or replace the remote control batteries when :   ◆ You purchase the air conditioner   ◆ The remote control does not work correctly   Note   ◆ Use two AAA, LR03 1.5V batteries.   ◆ Do not use old batteries or different kinds of batteries together.   ◆ Batteries may be completely discharged after 12 months, even   ◆ if they have not actually been used.   1 2 Push the battery cover on the rear of the remote control with your thumb   in the direction of the arrow and remove it.   Insert the two batteries, taking care to respect the polarities :   ◆ + on the battery with + on the remote control.   ◆ - on the battery with - on the remote control.   3 Close the cover by sliding it back until it clicks into place.   E-8   Selecting the Automatic Operating Mode   You can start the air conditioner in Automatic mode from your remote   control. In the Automatic mode, the standard temperature and the   optimum fan speed is selected automatically. You can adjust the   standard temperature but not the fan speed.   1 If necessary, press the   (On/Off) button.   Result:   ◆ The operation indicator on the indoor unit lights up.   ◆ The air conditioner starts up in the mode selected   when the unit was last used.   ◆ The indoor unit beeps.   IMPORTANT   The air conditioner is fitted with a protection mechanism to   prevent the unit from being damaged when it is started   immediately after being:   ◆ Plugged in   ◆ Stopped   lt will start up normally after three minutes.   2 If the   is not displayed at the top of the remote control,   press the   appears.   button on the remote control one or more times until it   Result:   ◆ The indoor unit beeps each time you press the   button.   ◆ The air conditioner runs in AUTO mode.   Note   You can change modes at any time.   3 To adjust the standard temperature (The air conditioner automatically   set the standard temperature by the current room temperature.),   press the   button one or more times.   SET TEMP. SET TEMP.   -2°C -1°C   < When you feel hot >   - SET TEMP. SET TEMP.   +1°C +2°C   < When you feel chilly >   Standard temperature   E-9   Cooling Your Room   You must select the Cool mode if you wish to adjust the:   ◆ Cooling temperature   ◆ Fan speed when cooling   1 If necessary, press the   (On/Off) button.   Result: The operation indicator on the indoor unit lights up.   ◆ ◆ The air conditioner starts up in the mode selected   when the unit was last used.   ◆ The indoor unit beeps.   IMPORTANT   The air conditioner is fitted with a protection mechanism to   prevent the unit from being damaged when it is started   immediately after being:   ◆ Plugged in   ◆ Stopped   lt will start up normally after three minutes.   2 If the   is not displayed at the top of the remote control,   press the   appears.   button on the remote control one or more times until it   Result:   ◆ ◆ The indoor unit beeps each time you press the   The air conditioner runs in COOL mode.   button.   Note   You can change modes at any time.   3 To adjust the temperature, press the   the required temperature is displayed.   button one or more times until   Possible temperatures are between 18°C and 30°C inclusive.   Result: Each time you press the button:   ◆ - The temperature is adjusted by 1°C   - The indoor unit beeps   ◆ The air conditioner starts cooling, provided that the room   temperature is higher than the selected temperature.   ◆ If the room temperature reaches the set temperature, the air   conditioner stops cooling, but the fan is still operating.   4 Select the fan speed by pressing the   until the required setting is displayed:   button one or more times   ) Automatic (rotated :   Low   Medium   High   Result:   Each time you press the   beeps.   button, the indoor unit   5 To control the direction of the air flow, refer to page 15.   E-10   Changing the Room Temperature Quickly   The Turbo cooling function is used to cool your room as quickly as possible.   Example :   You have just come home and find that the room is very   hot. You wish to cool it down as quickly as possible.   The Turbo function operates for 30 minutes with the maximum settings before   returning automatically to the mode and temperature previously selected.   1 If necessary, press the   (On/Off) button.   Result:   ◆ The operation indicator on the indoor unit lights up.   ◆ The air conditioner starts up in the mode selected when the unit   was last used.   ◆ The indoor unit beeps.   2 Press the   Result:   button.   ◆ The temperature and fan settings are adjusted automatically.   ◆ The air conditioner cools the room as quickly as possible.   ◆ After 30 minutes, the air conditioner is reset automatically to the   previous mode, temperature and fan settings.   But, if you press the   button in DRY or FAN mode,   it will change to AUTO mode automatically.   3 If you wish to stop the Turbo function before the end of the 30-minute period,   press the   button one or more times until   or   disappears.   Result:   The air conditioner is reset automatically to the previous mode,   temperature and fan settings.   4 To control the direction of the air flow, refer to page 15.   E-11   Removing Excess Humidity   If the atmosphere in your room is very humid or damp, you can remove   excess humidity without lowering the room temperature too much.   1 If necessary, press the   (On/Off) button.   Result: The operation indicator on the indoor unit lights up.   ◆ ◆ The air conditioner starts up in the mode selected when   the unit was last used.   ◆ The indoor unit beeps.   IMPORTANT   The air conditioner is fitted with a protection mechanism   to prevent the unit from being damaged when it is started   immediately after being:   ◆ Plugged in   ◆ Stopped   It will start up normally after three minutes.   2 If the   is not displayed at the top of the remote control, press the   button on the remote control one or more times until it appears.   Result:   ◆ ◆ The indoor unit beeps each time you press the   The air conditioner runs in DRY mode.   button.   Note   You can change modes at any time.   3 To adjust the temperature, press the   button one or more times   until the required temperature is displayed.   Possible temperatures are between 18°C and 30°C inclusive.   Result: ◆ Each time you press the button:   - The temperature is adjusted by 1°C   - The indoor unit beeps   ◆ The air conditioner starts removing the excess humidity;   the quantity of air is adjusted automatically.   4 To control the direction of the air flow, refer to page 15.   E-12   Airing Your Room   If the atmosphere in your room is stale, you can air the room using   the Fan feature.   1 If necessary, press the   (On/Off) button.   Result:   ◆ The operation indicator on the indoor unit lights up.   ◆ The air conditioner starts up in the mode selected when   the unit was last used.   ◆ The indoor unit beeps.   2 If the   is not displayed at the top of the remote control,   press the   appears.   button on the remote control one or more times until it   Result:   ◆ ◆ ◆ The indoor unit beeps each time you press the   The air conditioner runs in FAN mode.   The temperature is set automatically.   button.   Note   You can change modes at any time.   3 Select the fan speed by pressing the   until the required setting is displayed:   button one or more times   Low   Medium   High   Result: Each time you press the   button, the indoor unit beeps.   4 To control the direction of the air flow, refer to page 15.   E-13   Selecting Energy Saving Mode   If you wish to save energy when using your air conditioner, select the   Energy saving mode with the Energy saving button.   1 If necessary, press the   (On/Off) button.   Result:   ◆ The operation indicator on the indoor unit lights up.   ◆ The air conditioner starts up in the mode selected   when the unit was last used.   ◆ The indoor unit beeps.   IMPORTANT   The air conditioner is fitted with a protection mechanism to   prevent the unit from being damaged when it is started   immediately after being:   ◆ Plugged in   ◆ Stopped   lt will start up normally after three minutes.   2 Select COOL mode by pressing the   button.   Note   You can select the Energy saving mode only in COOL mode.   3 4 Press the   Result:   button.   ◆ ◆ ◆ ◆ The indoor unit beeps.   The air conditioner runs in the Energy saving mode.   The outer air flow blade moves up and down.   To stop the Energy saving mode, press the   again.   To adjust the temperature, press the   button one or more times   until the required temperature is displayed. Possible temperatures are   between 26°C and 30°C inclusive.   Note   If you want to adjust temperature under 26°C, cancel the   Energy saving mode before adjusting the temperature.   5 6 To select the fan speed, press the   the required setting is displayed.   button one or more times until   To control the direction of the air flow, refer to page 15.   E-14   Adjusting the Air Flow Direction Vertically   Depending on the position of the indoor unit on the wall of your   room, you can adjust the position of the outer air flow blade on the   bottom of the unit, thus increasing the efficiency of the air   conditioner.   1 Press the   button one or more times as required.   Result: The outer blade is adjusted vertically.   RECOMMENDATION   When...   Adjust the blade to face...   Cooling   Upwards.   2 If you want the blade to move up and down automatically when the air   conditioner is operating, press the   button.   Result: The blade move up and down, around the base position set.   3 To stop the blade moving up and down, press the   button again.   Note   If you switch the air conditioner... Then the blade is...   Off   Closed completely.   Set to the initial position powered.   On again   Adjusting the Air Flow Direction Horizontally   There are two sets of inner air flow blades. Just as the outer air flow   blade can be adjusted vertically, the inner blades can be adjusted   horizontally.   1 Adjust each set of inner blades to the required position, by pushing or   pulling them sideways.   E-15   Setting the On Timer   The On Timer enables you to switch on the air conditioner automatically   after a given period of time. You can set the period of time from   30 minutes to 24 hours.   1 To set the operating time, press the   button one or more times until   the required time is displayed. Possible time is between 0.5 hour and 24   hour inclusive.   2 Press the   (Set/Cancel) button to complete the setting.   Result: ◆ The remaining time is displayed.   ◆ Blinking of the timer indicator stops.   ◆ The selected mode and the temperature on the display   disappear after 10 seconds.   ◆ The air conditioner will switch on automatically when the   counter displayed on the remote control reaches the set time   and disappears the On timer setting.   3 To select an operating mode in advance, press the   button until the   desired mode is displayed at the top of the remote control.   Result: ◆ The air conditioner will run in the selected mode when it is   turned on.   To Cancel the On Timer   1 To cancel the On Timer, press the   timer setting disappears.   button one or more times until the   2 Press the   (Set/Cancel) button.   Note   If you want to turn on the air conditioner before the timer reaches   the setting time, press the (ON/OFF) button.   E-16   Setting the Off Timer   The Off Timer enables you to switch off the air conditioner automatically   after a given period of time. You can set the period of time from   30 minutes to 24 hours.   1 To set the operating time, press the   button one or more times until   the required time is displayed. Possible time is between 0.5 hour and 24   hour inclusive.   2 Press the   (Set/Cancel) button to complete the setting.   Result: ◆ The remaining time is displayed.   ◆ Blinking of the timer indicator stops.   ◆ The air conditioner will switch off automatically when the   counter displayed on the remote control reaches the set time   and disappears the Off timer setting.   Example If you would like to turn the air conditioner on after 2 hours   and to operate it for 2 hours:   1. Press the   button until ‘2.0 Hr’ is displayed.   2. Press the (Set/Cancel) button.   3. Press the   button until ‘4.0 Hr’ is displayed.   4. Press the (Set/Cancel) button.   Note   You can see or change the setting mode and/or the temperature   by pressing the   Off timer.   button or the   button after setting the   To Cancel the Off Timer   1 To cancel the Off Timer, press the   timer setting disappears.   button one or more times until the   2 Press the   (Set/Cancel) button.   Note   If you want to turn off the air conditioner before the timer reaches   the setting time, press the (ON/OFF) button.   E-17   Setting the Sleep Timer   The Sleep Timer can be used when you are cooling your room to   switch the air conditioner off automatically after a period of six   hours.   Note   If you wish to switch the unit off at a specific time, refer to   page 17.   1 2 Make sure that you have selected COOL mode.   Press the   button one or more times until   appears on the   remote control.   Result: ◆ The indoor unit beeps.   ◆ The air conditioner will be controlled as indicated in the   illustrations below.   Cooling The desired temperature is   increased by 1°C every hour.   When it has been increased   by 2°C (after two hours), the   temperature is maintained for   four hours.   To Cancel the Sleep Timer   If you no longer wish to use the Sleep Timer that you have set, you   can cancel it at any time.   Press the   Result:   button.   ◆ ◆ ◆ The indoor unit beeps.   The   is no longer displayed.   The air conditioner operates normally.   E-18   Operating Recommendations   Here are a few recommendations that you should follow when using   your air conditioner.   Topic   Recommendation   Power failure   If a power failure occurs when the air   conditioner is operating, the unit is switched off.   When the power returns, the air conditioner   starts up again automatically.   Temperature and Humidity Ranges   The following table indicates the temperature and humidity ranges within which the air conditioner can be used.   If the air conditioner is used at...   Then...   High temperatures   The automatic protection feature may be triggered and the air conditioner stopped.   Low temperatures   A water leak or some other malfunction may occur if the heat exchanger freezes.   Water may condense on and drip from the surface of the indoor unit if it is used for long periods.   High humidity levels   Mode   Outdoor Temperature   Indoor Temperature   Indoor Humidity   Cooling   Drying   21°C to 43°C approx.   18°C to 43°C approx.   18°C to 32°C approx.   18°C to 32°C approx.   80% or less   - ◆◆ If the cooling operation is used at over 33°C(indoor temperature) then, it does not cool at its full capacity.   E-19   Operating Your Air Conditioner Without the Remote Control   Your air conditioner can be operated directly from the indoor unit if   the remote control is lost or broken.   1 2 Slide the lower front grille down.   To switch the air conditioner on, press the ON/OFF switch on the right   side of the indoor unit.   Result: ◆ The OPERATION indicator on the indoor unit comes on.   ◆ The indoor unit beeps.   ◆ The air conditioner starts up in the most suitable mode for   the room temperature:   Room Temperature   Operating Mode Temperature Setting   Cool 24°C approx.   21°C or above   3 To switch the air conditioner off, press the ON/OFF switch again.   Note   Even if the air conditioner has been switched on via the   ON/OFF switch, operations can still be controlled using the   remote control as usual.   E-20   Solving Common Problems   Before contacting the after-sales service, perform the following simple checks.   They may save you the time and expense of an unnecessary call.   Problem   Explanation/Solution   The air conditioner does not   operate at all   ◆ Check that the breaker used for the air conditioner is switched on.   ◆ Check that the operation indicator on the indoor unit is on;   if necessary press the   (On/Off) button on the remote control.   ◆ Check whether the TIMER indicator on the indoor unit is switched on.   If so:   - Wait until the switch-on time is reached and the air conditioner starts   up automatically   - Cancel the timer (see pages 16 and 17 for further details)   The air conditioner does not   operate with the remote control   ◆ Check that there are no obstacles between you and the indoor unit.   ◆ Check the remote control batteries.   ◆ Check that you are close enough to the indoor unit (seven meters/   yards or less).   No beep is heard when you press   ◆ Check that you are pointing the remote control at the remote control   sensor in the right of the indoor unit.   the   (On/Off) on the remote   control   ◆ Replace the remote control batteries if necessary.   The air conditioner does not cool   ◆ Check that the correct operating mode has been selected (AUTO,   COOL).   ◆ The room temperature may be too low.   ◆ Dust may be blocking the air filter guard; refer to page 22 for cleaning   instructions.   ◆ Check that there is no obstacle in front of the outdoor unit.   The fan speed does not change   ◆ Check that the operating mode is set to COOL or FAN ; in the   AUTO mode, the fan speed changes automatically and in the   DRY mode, it is set to AUTO.   when you press the   button   The air flow direction does not   change when you press the   button   ◆ Check that the air conditioner has been switched on; if necessary,   press the   (On/Off) button on the remote control.   The timer is not correctly triggered   ◆ Check that the timer has been programmed correctly; see pages 16   and 17.   Odours are permeated in the room ◆ Air the room.   during air conditioning   E-21   Cleaning Your Air Conditioner   To get the best possible use out of your air conditioner, you must   clean it regularly to remove the dust that accumulates on the air filter.   Before cleaning your air conditioner, ensure that you   have switched off the breaker used for the unit.   IMPORTANT   1 2 3 Slide the lower front grille down.   Open the upper front grille by pulling right and left sides of the grille.   Lift out the bottom edge of the air filters and pull down to release them.   Upper front   grille   Hook   4 5 Remove all dust on the air filters with a vacuum cleaner or brush.   Body   groove   When you have finished, insert the top part of the filters into their slot   and push down on the bottom edge until they click into place.   6 Clean the front grille with a damp cloth and mild detergent (do NOT use   benzene, solvents or other chemicals).   Note ◆◆ If you have not used the air conditioner for a long period of time, set the fan   going for three to four hours to dry the inside of the air conditioner thoroughly.   Lower   front   grille   Body groove   Hook   Cleaning Deodorizing and Bio-Green filters (Option)   ◆◆07/09◆◆   To remove minute dust particles and odors, deodorizing and Bio-Green   filters are installed in the air conditioner. You should clean the filters   every 3 months.   Deodorizing filter   1 Open the upper front grille by pulling right and left sides of the grille.   2 Pull out the deodorizing and Bio-Green filters.   Bio-Green Filter   ◆◆12/14/18/24◆◆   3 4 Wash the filters with clean water, then dry them in the shade.   Insert the filters into the original position.   Bio-Green Filter   Note   You can change the position of filters with each other.   5 Close the front grille.   Deodorizing filter   E-22   Technical Specifications   Model Indoor unit   Power Supply   AS07S8GE   AS07SBGE   AS09S8GE   AS09SBGE   AS12SBGE   AS12SGGE   AS18S0GE   AST24S6GE   220-240V~, 50Hz   AS07S8GB   AS09S8GB   AS12SGGB   AS14SGGB   AS18S0GB   AS24S6GB   220V~, 60Hz   E-23   THIS AIR CONDITIONER IS MANUFACTURED BY:   ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR:   CE CLIMATISEUR EST FABRIQUE PAR:   QUESTO CONDIZIONATORE D’ARIA È PRODOTTO DA:   ESTE APARELHO DE AR CONDICIONADO É FABRICADO POR:   DIESE KLIMAANLAGE IST FABRIZIERT VON:   AYTH H ™Y™KEYH KATA™KEYA™THKE A¶O:   ELECTRONICS   |