Safety Precautions
The following safety precautions must be taken when using your air conditioner.
Risk of electric shock. • Can cause injury or death. • Disconnect all
WARNING
remote electric power supplies before servicing, installing or cleaning.
• This must be done by the manufacturer or its service agent or a similar
qualified person in order to avoid a hazard.
Users of this product are cautioned not to attempt repair of this product at their
own discretion. Instead, they are requested to directly contact a designated
service center or the outlet at which the product was purchased.
DURING OPERATION
Never spill any kind of liquid into the unit. Should this happen, unplug or main
switch off the unit and contact an authorized service center.
Do not insert anything between the air outlet blades because the inner fan may
be damaged and could cause injury. Keep children away from the unit.
Do not place any obstacles in front of the unit.
Do not spray liquid of any kind into the indoor unit. Should this happen, switch off
the breaker used for your air conditioner and contact your installation specialist.
Make sure that the unit is correctly ventilated at all times:
Do not place clothing or other materials over it.
If the wireless remote control will not be used for a long time, remove the
batteries. (If applicable)
When using a wireless remote control, the distance should not be more than 7
meters from the air conditioner. (If applicable)
The air conditioner must be plugged into its own specific power source, which
must be installed in compliance with national wiring,earthing and safety
regulations.
If the power cord is damaged in any way, it must be replaced by the manufacturer
or its service agent or a similarly qualified person in order to avoid a hazard.
This device must be installed according to the national electrical rules.
The appliance must be installation that the plug should be easily accessible
after installation.
If the fuse on PC board is broken please change it with the type of T 3.15A 250V.
The breaker of the air conditioner should be all-pole switch; and the distance
between its two contacts should be no less than 3.5mm. Such means for
disconnection must be incorporation in the fixed wiring.
Before throwing out the device, it is necessary to pull back the battery cells and
get rid of them safely for recycling reasons.
DISPOSING OF THE UNIT
When you need to dispose of the unit, consult your dealer. If pipes are removed
incorrectly, refrigerant may blow out and come into contact with your skin,causing
injury. Releasing refrigerant into the atmosphere also damages the environments.
Please recycle or dispose of the packaging material for this product in an
environmentally responsible manner.
Never store or ship the air conditioner upside down or sideways to avoid damage
to the compressor.
OTHERS
The appliance is not intended for use by young children or infirm persons without
supervision: Young children should be supervised to ensure that they do not play
with the appliance.
Max current is measured according to IEC standard for safety and current is
measured according to ISO standard for energy efficiency.
E-2
Air Conditioning Unit - Main Parts and Control Panel
◆ The design and shape are subject to
change, depending on the model.
Inner air flow blades
(right/left orientation)
Outer air flow blades
(up/down orientation)
Air inlet(Inside)
Air filter(Inside)
Air inlet (Outside)
Ventilation lever
Power Cable
BLUE BROWN YELLOW/GREEN
◆◆Power cable connection
should be committed to
an installation engineer.
Main Power Earth
Cooling lamp
Operating
mode
selection dial
Temperature
control dial
Air flow blade swing switch
E-4
Getting Started
You have just purchased a window-type room air conditioner and it has been installed
by your installation specialist.
Your Owner’s Instructions contain much valuable information on using your air conditioner.
Please take the time to read them as they will help you take full advantage of the unit’s features.
The booklet is organized as follows.
◆ The illustration on page 4 shows the air conditioning unit;
it indicates the location and purpose of the main parts and controls on the unit.
◆◆In the main part of the document, you will find a series of step-by-step
procedures for each function available.
The illustrations in the step-by-step procedures use four different symbols:
◆
◆
PRESS
PUSH
IMPORTANT
NOTE
E-5
Cooling Your Room
You must select the Cool mode if you wish to lower the temperature
in your room. You can also set the fan speed.
Select the operating mode and fan speed.
1
To cool your room
with a...
Set the operating mode
selection dial to...
High fan speed
Mid fan speed
Low fan speed
HI COOL
MID COOL
LOW COOL
Result: ◆◆The air conditioner starts up in Cool mode.
◆◆The fan starts up at the speed selected.
You can change modes at any time.
◆
2
To adjust the temperature, turn the temperature control dial
to the desired position.
27˚C ~ 23˚C
Possible temperatures: Between 18°C and 29°C inclusive.
27˚C
~ 29C
23˚C
~ 18˚C
Result: The air conditioner is started cooling as turn on the
cooling lamp, if room temperature is higher than selected
temperature.
3
To control the direction of the air flow, refer to page 8.
E-6
Airing Your Room
If the atmosphere in your room is stale, you can air it using
the Fan feature and if necessary, evacuate the stale air outside.
If you wish to evacuate stale air outside, push the ventilation lever on the front
of the unit to the right and the open position ( ).
1
Result: The air inside the room circulates and stale air is evacuated outside.
Otherwise, push the ventilation lever to the left and the closed position (
Result: The air simply circulates inside the room.
).
2
Set the operating mode selection dial to the HI FAN, MID FAN or LOW FAN
position.
HI FAN : The fan turns high speed.
MID FAN : The fan turns mid speed.
LOW FAN : The fan turns low speed.
◆
Result:
The air conditioner starts up in Fan mode.
To control the direction of the air flow, refer to page 8.
3
Switching the Air Conditioner Off
You can switch the air conditioner off whenever you want.
To switch the unit off, simply set the operating mode selection dial
to the OFF position.
1
Result:
The air conditioner stops operating.
E-7
Adjusting the Air Flow Direction Horizontally
Depending on the position of the unit in your room, you can adjust the
orientation of the inner air flow blades on the right-hand side of the
unit, thus increasing the efficiency of the air conditioner.
Set the air flow blade swing switch to the ON position.
Result: The inner blades swing automatically left and right.
1
2
To stop the blades moving left and right, set the air flow blade swing switch
to the OFF position.
To stop the blades in a specific position and orient the air flow in the
corresponding direction, simply set the switch to the OFF position
◆
when the blades are in the desired position.
Adjusting the Air Flow Direction Vertically
Again depending on the position of the unit in your room, you can
adjust the orientation of the outer air flow blades on the right-hand
side of the unit.
RECOMMENDATION When...
Adjust the blades to face...
Cooling
Upwards.
Adjust the air flow blades to the desired position, by pushing them
upwards or downwards.
If you orient the air flow blades downwards and the unit operates
in Cool mode for long periods of time, dew may:
◆
◆◆◆Form on the surface of the blades
◆◆◆Drip from the blades
E-8
Operating Recommendation
Here is a recommendations that you should follow when using your air
conditioner.
Topic
Recommendation
Power failure If a power failure occurs when the air conditioner is operating,
the unit is switched off. When the power returns,
the air conditioner starts up again automatically.
Temperature and Humidity Ranges
The following table indicates the temperature and humidity ranges,
within which the air conditioner can be used.
Mode
Outdoor
Indoor
Indoor Humidity
Temperature
Temperature
Cooling
21°C to 54°C approx.
21°C to 32°C approx.
80% or less
If the air conditioner is used at...
Then...
Higher temperature
The automatic protection feature may be triggered
and the air conditioner stopped.
Lower temperature
A water leakage or some other malfunction may happen
if the heat exchanger freezes.
Higher humidity levels
Water may condense on and drip from the surface of the unit
if it is used for long periods.
E-9
Cleaning Your Air Conditioner
Be sure to clean the air filter periodically two weeks to maintain the air con-
ditioner in the best condition for a long period of time.
When cleaning the air conditioner, turn it off and pull out
the power plug.
IMPORTANT
1
Hold the air filter handle, slightly pull it to the left side and open the front grille.
Note
The removal of the front grille makes it easier to clean the air
conditioner. Open the grille as much as possible.
CAUTION
Removal and Reassembly of the Front Grille
For user's safety, a safety clip has been installed in the front grille.
1
Grasp the lower part of the
front grille and the air filter
handle, then open the grille.
Safety clip
2
3
Remove the safety clip and
the front grille.
When reassembling the front
grille, you should install the
safety clip again.
2
3
Pull the air filter to the right side.
Remove all dust on the air filter with a vacuum cleaner or brush.
4
5
When you have finished, insert the air filter back into its original position.
Wipe the surface of the unit with a neutral detergent and then wipe it again
with dry cloth.
(Be sure not to use benzene, solvent or other chemical products.)
If you...
Then...
◆
Will not be using the
air conditioner for a
long period of time
◆◆Set the fan going for three to four hours
to dry the inside of the air conditioner
thoroughly.
◆◆Switch the air conditioner off and
unplug it from the wall socket.
◆◆Clean the filter and outer surfaces.
Have not used the air
conditioner for a long
period of time
Set the fan going for a few hours to
dry the inside of the air conditioner
thoroughly.
E-10
Solving Common Problems
Before contacting the after-sales service, perform the following simple checks.
They may save you the time and expense of an unnecessary call.
PROBLEM
EXPLANATION / SOLUTION
◆◆ Check that the circuit breaker used for the air conditioner
The air conditioner does not
operate at all
has not been triggered.
◆
◆
Check that the power cable is plugged into a wall socket and the
socket is switched on, if necessary.
Check that the correct operating mode has been selected
(cooling or airing).
◆◆◆Check that the correct operating mode has been selected.
The air conditioner does not
cool
◆◆◆The room temperature may be too low.
◆◆◆Dust may be blocking the air filter;
refer to page 10 for cleaning instructions.
◆◆◆Check that there is no obstacle blocking the air flow into or out of the unit.
◆◆◆Check that the air conditioner has been switched on;
if necessary, turn the operating mode selection dial.
The air flow direction does not
change when you set the air flow
blade swing switch to the ON
position
◆◆◆Air the room.
Odours are permeated in the
room during air conditioning
Technical Specifications
Design and specifications are subject to change without notice.
Model
Power Supply
AWT24F1ME
AWT24F1MEB/EC
AWT18F1ME
AWT18F1MEA/EB/EC
AWT19F1MEA
220-240V~, 50Hz
AWT24F1MB
AWT24F1MBA/BC
AWT20F1MB
220V~, 60Hz
AWT20F1MBA
AWT18F1MBB/BC
E-11
Method of Installation
Before installation, be sure to check the installation area
for the air conditioner, and installation method of the drain hose.
Checkpoints prior to installation
1 Check the cabinet and front grille of the unit for any harmful defects
such as scratches.
2 Be sure to check the power supply.
- Refer to the specifications on the label attached to the unit.
Installation Conditions
1 As the unit is heavy, the wall or window of the installation area should
have sufficient strength and durability for operation of the air conditioner,
and for prevention of any vibration or noise.
If it is weak, reinforcement work should be performed separately.
2 It is advisable to install the air conditioner in the north or west side to
prevent the effect of direct sunlight.
When installing it in the south or east side due to unavoidable
circumstances, it is advisable to install the sunshade to prevent the
direct sunlight.
In this case, take care not to cause any hindrance to the flow of outside air.
3 When installing the air conditioner, be sure to obtain sufficient space on
the rear side of the unit for smooth flow of air.
When operating the air conditioner in closed areas such as inner building
with cooling operation, and result in trouble with the unit.
See the illustration below.
Awning
75mm
min.
300mm
240mm
500mm
Fence, wall
or other
obstacle
500mm
500mm
Approx.3
˚
750mm
150mm min.
Note
◆◆If the wall is greater than 150mm thick,
cut the wall back on a 45˚ angle if possible.
Outdoor side
Indoor side
45˚
45˚
100mm or more
E-12
Method of Installation
Installation of the Drain Tube
Rear
Fix the drain tube as shown in the figure.
Rubber cap
Gasket
Drain Tube
Screws(2EA)
Installation of the Drain Pan
The procedure for installing the drain pan should be determined by the
condition of the installing area.
◆◆In the case of an area where the drain pan can not be directly
installed on the rear side of the unit after installing the air conditioner.
Example: High storage
Open the front grille.
1
Safety clip
CAUTION
Removal and Reassembly of the Front Grille
For user's safety, a safety clip has been installed in the front grille.
1
Grasp the lower part of the front grille and the air filter handle, then
open the grille.
2
3
Remove the safety clip and the front grille.
When reassembling the front grille, you should install the safety
clip again.
Remove the front panel.
2
2-1 Press both sides of the cabinet in the direction of the arrow
as shown in the figure.
2-2 Pull the lower part of the front panel slightly forward.
(below three inches)
2-3 Lift the front panel upward.
Applying excessive force to remove the front panel
Front panel
◆
may cause damage to the tab ; be sure not to use
excessive force.
Remove two screws on the lower, right and left sides of the unit.
3
E-13
Method of Installation
Remove the chassis from the cabinet.
4
5
6
Drain Pan
Rear
Remove the rubber cap inserted into the basepan.
Fix the drain pan as shown in the figure, and then connect the drain hose.
(You can use any commercially-available drain hose.)
Rubber cap
Drain Hose
Screw
7
Install the cabinet at the specified area after installing the drain pan,
and then re-assemble it in the original condition.
Bottom-Side View with
Drain Pan and Hose in Place
◆◆When assembling the front panel be sure to fix with a supplied screw.
(TH 2S 4X10)
◆◆In the case of an area where the drain pan can be directly installed
on the rear side of the unit after installing the air conditioner.
Screw
Follow steps 5 and 6 only.
1
E-14
Memo
E-15
THIS AIR CONDITIONER IS MANUFACTURED BY:
|
Mitsubishi Electronics Msz A26yv User Manual
Monarch Portable 1071 4860 122 User Manual
Ricoh Aficio Ld127 User Manual
Samsung Acc2800c User Manual
Samsung Aw1801m User Manual
Sanyo Cr14500 User Manual
Sharp Air Cleaner Fp A28u User Manual
Toshiba Ras 16gavp E User Manual
Trane Tcont800as11aa User Manual
Xerox 6250 User Manual