| 	
		 ® 
					Combat AT-Series   
					Indirect-Fired Air Turnover Units   
					Dimension and   
					Selection Guide   
					1.800.828.7450   
					
					™ 
					Quality in Any Language   
				AT-Series Heating Unit with Filtration   
					K 
					DA   
					DA   
					DA   
					DA   
					H 
					J 
					F 
					F 
					LIFTING   
					ANGLES   
					CONTROL   
					PANEL   
					D 
					INSPECTION   
					AND RELIEF   
					PORT   
					E 
					SPLIT   
					FOR   
					SHIPMENT   
					C 
					G 
					RA   
					RA   
					RA   
					RA   
					L 
					N 
					L 
					M 
					B 
					M 
					A 
					FRONT VIEW   
					END VIEW   
					DIMENSIONS   
					LEGEND   
					AT-136 AT-148 AT-154 AT-236 AT-242 AT-248 AT-254 AT-260 AT-272   
					DA = Discharge Air   
					A 
					B 
					C 
					60   
					50   
					75   
					72   
					60   
					75   
					85   
					72   
					86   
					90   
					50   
					60   
					100   
					55   
					66   
					116   
					60   
					66   
					145   
					72   
					72   
					160   
					84   
					72   
					165   
					90   
					76   
					RA = Return Air   
					75 - 53   
					75 - 53 100 - 53   
					100 - 53 125 - 72   
					125 - 72 150 - 72   
					175 - 72   
					D 
					53   
					53   
					65   
					53   
					90   
					96   
					96   
					IMPORTANT NOTES:   
					• All dimensions are subject to change   
					without notice.   
					• Due to height of unit, additional support is   
					recommended on top of the unit.   
					• Dimension "F" is flue diameter. Flue located   
					on left side of unit for 1,000 MBH heat   
					exchanger and smaller; flue located on right   
					side of unit for 1,250 MBH heat exchanger   
					and larger.   
					• Dimensions "D" and "F" may vary depending   
					on heat exchanger size (ex. 45 = 450 MBH   
					heat exchanger).   
					• All dimensions are in inches.   
					E 
					F 
					35   
					35   
					35   
					35   
					35   
					35   
					35   
					35   
					35   
					45 - 6   
					75 - 6   
					45 - 6   
					75 - 6   
					45 - 6   
					75 - 6   
					45 - 6   
					75 - 6   
					75 - 6 175 - 12 300 - 14 300 - 14   
					70 - 6 100 - 8 100 - 8 225 - 12 450 - 16 450 - 16   
					100 - 8 100 - 8 100 - 8 100 - 8 125 - 10 125 - 10 300 - 14   
					125 - 10   
					175 - 12   
					G 
					H 
					J 
					K 
					L 
					3 
					24   
					48   
					.75   
					.75   
					6 
					3 
					24   
					48   
					.75   
					.75   
					6 
					3 
					3 
					24   
					48   
					.75   
					.75   
					6 
					3 
					30   
					48   
					.75   
					.75   
					6 
					3 
					4 
					36   
					48   
					.75   
					.75   
					6 
					4 
					36   
					48   
					.75   
					.75   
					6 
					4 
					40   
					48   
					.75   
					.75   
					6 
					36   
					48   
					.75   
					.75   
					6 
					30   
					48   
					.75   
					.75   
					6 
					M 
					N 
					3 
					3 
					3 
					3 
					3 
					3 
					3 
					3 
					3 
					3 
				AT-Series Cooling Unit with Filtration   
					H 
					DA   
					DA   
					DA   
					DA   
					F 
					D 
					LIFTING   
					ANGLES   
					M 
					SPLIT   
					FOR   
					G 
					SHIPMENT   
					C 
					RA   
					RA   
					RA   
					RA   
					L 
					E 
					J 
					J 
					K 
					A 
					K 
					B 
					FRONT VIEW   
					END VIEW   
					DIMENSIONS   
					LEGEND   
					AT-136 AT-148 AT-154 AT-236 AT-242 AT-248 AT-254 AT-260 AT-272   
					DA = Discharge Air   
					A 
					B 
					C 
					D 
					E 
					F 
					G 
					H 
					J 
					60   
					50   
					75   
					48   
					6 
					72   
					60   
					85   
					48   
					6 
					85   
					72   
					95   
					48   
					6 
					90   
					50   
					85   
					48   
					6 
					100   
					55   
					85   
					48   
					6 
					116   
					60   
					95   
					48   
					6 
					145   
					72   
					90   
					48   
					6 
					160   
					84   
					90   
					48   
					6 
					165   
					90   
					90   
					48   
					6 
					RA = Return Air   
					24   
					24   
					36   
					10   
					.75   
					.75   
					6 
					24   
					10   
					.75   
					.75   
					6 
					30   
					16   
					.75   
					.75   
					6 
					30   
					6 
					.75   
					.75   
					6 
					36   
					36   
					40   
					10   
					.75   
					.75   
					6 
					IMPORTANT NOTES:   
					• All dimensions are in inches.   
					• All dimensions are subject to change   
					without notice.   
					.75   
					.75   
					6 
					.75   
					.75   
					6 
					.75   
					.75   
					6 
					.75   
					.75   
					6 
					K 
					L 
					M 
					• Due to height of unit, additional support is   
					recommended on top of the unit.   
					3 
					3 
					3 
					3 
					3 
					3 
					3 
					3 
					3 
					N/A   
					N/A   
					N/A   
					N/A   
					N/A   
					N/A   
					50   
					50   
					50   
					4 
				AT-Series Heating and Cooling Unit with Filtration   
					K 
					DA   
					DA   
					DA   
					H 
					DA   
					E 
					LIFTING   
					ANGLES   
					F 
					F 
					CONTROL   
					PANEL   
					D 
					P 
					INSPECTION   
					AND   
					RELIEF PORT   
					Q 
					SPLIT   
					LIFTING   
					ANGLES   
					FOR   
					J 
					SHIPMENT   
					C 
					G 
					RA   
					RA   
					RA   
					RA   
					L 
					N 
					L 
					A 
					B 
					M 
					M 
					FRONT VIEW   
					END VIEW   
					DIMENSIONS   
					LEGEND   
					AT-136 AT-148 AT-154 AT-236 AT-242 AT-248 AT-254 AT-260 AT-272   
					DA = Discharge Air   
					A 
					B 
					C 
					60   
					50   
					75   
					72   
					60   
					85   
					85   
					72   
					95   
					90   
					50   
					85   
					100   
					55   
					85   
					116   
					60   
					95   
					145   
					72   
					90   
					160   
					84   
					90   
					165   
					90   
					90   
					RA = Return Air   
					75 - 53   
					75 - 53 100 - 53   
					100 - 53 125 - 72   
					125 - 72 150 - 72   
					175 - 72   
					D 
					53   
					53   
					65   
					53   
					90   
					48   
					96   
					48   
					96   
					48   
					IMPORTANT NOTES:   
					• All dimensions are subject to change   
					without notice.   
					• Due to height of unit, additional support   
					is recommended on top of the unit.   
					• Dimension "F" is flue diameter. Flue   
					located on left side of unit for 1,000 MBH   
					heat exchanger and smaller; flue located   
					on right side of unit for 1,250 MBH heat   
					exchanger and larger.   
					• Dimensions "D" and "F" may vary   
					depending on heat exchanger size   
					(ex. 45 = 450 MBH heat exchanger).   
					• All dimensions are in inches.   
					E 
					F 
					48   
					45 - 6   
					75 - 6   
					48   
					45 - 6   
					75 - 6   
					48   
					45 - 6   
					75 - 6   
					48   
					45 - 6   
					48   
					48   
					75 - 6   
					75 - 6 175 - 12 300 - 14 300 - 14   
					75 - 6 100 - 8 100 - 8 225 - 12 450 - 16 450 - 16   
					100 - 8 100 - 8 100 - 8 100 - 8 125 - 10 125 - 10 300 - 14   
					125 - 10   
					175 - 12   
					G 
					H 
					J 
					K 
					L 
					M 
					N 
					P 
					Q 
					6 
					24   
					6 
					24   
					6 
					36   
					10   
					.75   
					.75   
					6 
					3 
					N/A   
					35   
					6 
					24   
					10   
					.75   
					.75   
					6 
					3 
					N/A   
					35   
					6 
					30   
					16   
					.75   
					.75   
					6 
					6 
					30   
					6 
					.75   
					.75   
					6 
					6 
					36   
					6 
					36   
					6 
					40   
					10   
					.75   
					.75   
					6 
					3 
					50   
					35   
					.75   
					.75   
					6 
					3 
					N/A   
					35   
					.75   
					.75   
					6 
					3 
					N/A   
					35   
					.75   
					.75   
					6 
					3 
					50   
					35   
					.75   
					.75   
					6 
					3 
					50   
					35   
					3 
					3 
					N/A   
					35   
					N/A   
					35   
					5 
				AT-Series Estimated Shipping Weights   
					ESTIMATED SHIPPING WEIGHTS - BURNERS (ALL MODELS)   
					IMPORTANT NOTES:   
					• All weights are in pounds.   
					• All weights are subject to change   
					without notice.   
					• To determine total unit weight, add   
					the appropriate burner weight to the   
					appropriate base unit weight   
					(as listed in performance information   
					tables).   
					300 -   
					625   
					626 -   
					938   
					939 -   
					1250   
					1251 -   
					1875   
					1876 -   
					2500   
					2501 -   
					3125   
					3126 -   
					5000   
					Input MBH   
					GAS   
					BURNER   
					Weight   
					155   
					190   
					230   
					290   
					300   
					340   
					340   
					22.1 -   
					36   
					2.5 -   
					4.5   
					4.6 -   
					6.7   
					6.8 -   
					8.9   
					220   
					939 -   
					1250   
					6.8 -   
					8.9   
					9.0 -   
					13.4   
					220   
					1251 -   
					1875   
					9.0 -   
					13.4   
					13.5 -   
					17.9   
					310   
					1876 -   
					2500   
					13.5 -   
					17.9   
					18 -   
					22   
					Input GPH   
					Weight   
					#2 OIL BURNER   
					125   
					300 -   
					625   
					2.5 -   
					4.5   
					125   
					626 -   
					938   
					4.6 -   
					6.7   
					360   
					2501 -   
					3125   
					18 -   
					22   
					385   
					3126 -   
					5000   
					22.1 -   
					36   
					Input MBH   
					COMBINATION   
					GAS / #2 OIL   
					BURNER   
					Input GPH   
					Weight   
					200   
					240   
					270   
					360   
					400   
					450   
					500   
					AT-Series Selection Guide   
					To create a complete air turnover unit, choose one base unit and one burner/manifold package using the tables on the   
					following pages. Prices apply for natural gas or LPG units.   
					1. Choosing A Base Unit Package   
					Base Unit Package choice is based on model choice. First locate the correct set of tables on the following pages which corresponds to the required   
					type of unit. Locate CFM and MBH requirements on the appropriate set of tables to determine the unit model. If more than one model is applicable,   
					choose the smaller model.   
					Btu/h Output Required = CFM * 1.08 * Temperature Rise   
					MBH = Btu/h / 1,000   
					2. Choosing A Burner/Manifold Package   
					Choose Burner/Manifold Package based on input, burner type and insurance requirements. Choose a Burner/Manifold Package that can fulfill the   
					maximum output of the model. Note that burner INPUTS are listed rather than outputs.   
					Burner Input = Burner Output / .8   
					Tables A: Air Turnover Heating Unit Performance Information   
					(Additional configurations are available upon request.)   
					AT-136   
					AT-248   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					Temp. Rise   
					Range (°F)   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					CFM   
					Motor (HP)   
					4,500 1 (1 motor)   
					9,000 2 (1 motor)   
					12,000 3 (1 motor)   
					240   
					240   
					240   
					450   
					450   
					450   
					49 to 93   
					25 to 46   
					19 to 35   
					2,225   
					2,280   
					2,305   
					22,000 3 (2 motors)   
					35,000 5 (2 motors)   
					45,000 5 (2 motors)   
					45,000 5 (2 motors)   
					240   
					520   
					560   
					560   
					750   
					10 to 32   
					14 to 26   
					12 to 26   
					12 to 31   
					5,990   
					6,145   
					6,270   
					6,270   
					1,000   
					1,250   
					1,500   
					AT-148   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					3,255   
					3,300   
					AT-254   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					7,670   
					8,060   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					10,000 3 (1 motor)   
					16,000 3 (1 motor)   
					240   
					240   
					450   
					750   
					22 to 42   
					14 to 43   
					40,000 5 (2 motors)   
					60,000 7.5 (2 motors)   
					65,000 7.5 (2 motors)   
					560   
					600   
					600   
					1,750   
					2,250   
					2,500   
					13 to 41   
					9 to 35   
					9 to 36   
					AT-154   
					8,310   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					3,880   
					3,940   
					4,115   
					4,220   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					AT-260   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					10,870   
					11,135   
					11,135   
					14,000 3 (1 motor)   
					22,000 5 (1 motor)   
					30,000 7.5 (1 motor)   
					30,000 7.5 (1 motor)   
					240   
					240   
					520   
					560   
					450   
					750   
					1,000   
					1,250   
					16 to 30   
					10 to 32   
					16 to 31   
					17 to 39   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					54,000 5 (2 motors)   
					61,000 7.5 (2 motors)   
					74,000 7.5 (2 motors)   
					600   
					720   
					720   
					3,000   
					4,000   
					4,000   
					10 to 51   
					11 to 61   
					9 to 50   
					AT-236   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					3,945   
					3,990   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					AT-272   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					11,720   
					12,185   
					12,185   
					Temp. Rise   
					Range (°F)   
					9,000 1 (2 motors)   
					18,000 2 (2 motors)   
					24,000 3 (2 motors)   
					240   
					240   
					520   
					450   
					750   
					1,000   
					25 to 46   
					12 to 39   
					20 to 39   
					CFM   
					Motor (HP)   
					4,115   
					62,000 5 (2 motors)   
					88,000 10 (2 motors)   
					100,000 10 (2 motors)   
					600   
					720   
					720   
					3,000   
					4,500   
					4,500   
					9 to 45   
					8 to 47   
					7 to 42   
					AT-242   
					Output   
					(MBH)   
					Output   
					(MBH)   
					Temp.   
					Rise   
					Base Unit   
					Weight   
					(lbs.)   
					CFM   
					Motor (HP)   
					Minimum Maximum Range (°F)   
					21,000 2 (2 motors)   
					31,000 3 (2 motors)   
					31,000 3 (2 motors)   
					240   
					520   
					560   
					750   
					1,000   
					1,250   
					11 to 33   
					16 to 30   
					17 to 37   
					4,990   
					5,115   
					5,240   
					6 
				Tables B: Air Turnover Heating Unit with Filtration Performance Information   
					(Additional configurations are available upon request.)   
					AT-136   
					AT-248   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					Temp. Rise   
					Range (°F)   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					CFM   
					Motor (HP)   
					4,500 1 (1 motor)   
					9,000 3 (1 motor)   
					12,000 5 (1 motor)   
					240   
					240   
					240   
					450   
					450   
					450   
					49 to 93   
					25 to 46   
					19 to 35   
					2,425   
					2,505   
					2,520   
					22,000 3 (2 motors)   
					35,000 5 (2 motors)   
					45,000 7.5 (2 motors)   
					45,000 7.5 (2 motors)   
					240   
					520   
					560   
					560   
					750   
					10 to 32   
					14 to 26   
					12 to 26   
					12 to 31   
					6,190   
					6,345   
					6,575   
					6,730   
					1,000   
					1,250   
					1,500   
					AT-148   
					Output   
					(MBH)   
					Minimum Maximum   
					240   
					240   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					3,455   
					3,470   
					AT-254   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					7,870   
					8,310   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					10,000 3 (1 motor)   
					16,000 5 (1 motor)   
					450   
					750   
					22 to 42   
					14 to 43   
					40,000 5 (2 motors)   
					60,000 10 (2 motors)   
					65,000 10 (2 motors)   
					560   
					600   
					600   
					1,750   
					2,250   
					2,500   
					13 to 41   
					9 to 35   
					9 to 36   
					AT-154   
					8,560   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					4,080   
					4,140   
					4,210   
					4,420   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					AT-260   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					11,070   
					11,335   
					11,385   
					Temp. Rise   
					Range (°F)   
					14,000 3 (1 motor)   
					22,000 5 (1 motor)   
					30,000 10 (1 motor)   
					30,000 10 (1 motor)   
					240   
					240   
					520   
					560   
					450   
					750   
					1,000   
					1,250   
					16 to 30   
					10 to 32   
					16 to 31   
					17 to 39   
					CFM   
					Motor (HP)   
					54,000 5 (2 motors)   
					61,000 7.5 (2 motors)   
					74,000 10 (2 motors)   
					600   
					720   
					720   
					3,000   
					4,000   
					4,000   
					10 to 51   
					11 to 61   
					9 to 50   
					AT-236   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					4,145   
					4,240   
					AT-272   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					9,000 1 (2 motors)   
					18,000 3 (2 motors)   
					24,000 5 (2 motors)   
					240   
					240   
					520   
					450   
					750   
					1,000   
					25 to 46   
					12 to 39   
					20 to 39   
					7.5 (2 mo-   
					tors)   
					62,000   
					600   
					3,000   
					9 to 45   
					12,160   
					4,270   
					88,000 10 (2 motors)   
					100,000 15 (2 motors)   
					720   
					720   
					4,500   
					4,500   
					8 to 47   
					7 to 42   
					12,385   
					12,515   
					AT-242   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					21,000 3 (2 motors)   
					31,000 5 (2 motors)   
					31,000 5 (2 motors)   
					240   
					520   
					560   
					750   
					1,000   
					1,250   
					11 to 33   
					16 to 30   
					17 to 37   
					5,240   
					5,270   
					5,445   
					Tables C: Air Turnover Cooling Unit with Filtration Performance Information   
					(For cooling applications, consult factory. Base Unit Weights do not account for inclusion of cooling coils or exclusion of heat exchanger.   
					Additional configurations are available upon request.)   
					AT-136   
					AT-248   
					CFM   
					Motor (HP)   
					Base Unit Weight (lbs.)   
					CFM   
					Motor (HP)   
					Base Unit Weight (lbs.)   
					4,500   
					9,000   
					12,000   
					1 (1 motor)   
					3 (1 motor)   
					5 (1 motor)   
					2,425   
					2,505   
					2,520   
					22,000   
					35,000   
					45,000   
					45,000   
					3 (2 motors)   
					5 (2 motors)   
					7.5 (2 motors)   
					7.5 (2 motors)   
					6,190   
					6,345   
					6,575   
					6,730   
					AT-148   
					AT-254   
					CFM   
					Motor (HP)   
					Base Unit Weight (lbs.)   
					CFM   
					Motor (HP)   
					Base Unit Weight (lbs.)   
					10,000   
					16,000   
					3 (1 motor)   
					5 (1 motor)   
					3,455   
					3,470   
					40,000   
					60,000   
					65,000   
					5 (2 motors)   
					10 (2 motors)   
					10 (2 motors)   
					7,870   
					8,310   
					8,560   
					AT-154   
					CFM   
					Motor (HP)   
					Base Unit Weight (lbs.)   
					AT-260   
					14,000   
					22,000   
					30,000   
					30,000   
					5 (1 motor)   
					5 (1 motor)   
					10 (1 motor)   
					10 (1 motor)   
					4,080   
					4,140   
					4,210   
					4,420   
					CFM   
					Motor (HP)   
					Base Unit Weight (lbs.)   
					54,000   
					61,000   
					74,000   
					5 (2 motors)   
					7.5 (2 motors)   
					10 (2 motors)   
					11,070   
					11,335   
					11,385   
					AT-236   
					AT-272   
					CFM   
					Motor (HP)   
					Base Unit Weight (lbs.)   
					CFM   
					Motor (HP)   
					Base Unit Weight (lbs.)   
					9,000   
					18,000   
					24,000   
					2 (1 motors)   
					3 (2 motors)   
					5 (2 motors)   
					4,145   
					4,240   
					4,270   
					62,000   
					88,000   
					100,000   
					7.5 (2 motors)   
					10 (2 motors)   
					15 (2 motors)   
					12,160   
					12,385   
					12,515   
					AT-242   
					CFM   
					Motor (HP)   
					Base Unit Weight (lbs.)   
					21,000   
					31,000   
					31,000   
					3 (2 motors)   
					5 (3 motors)   
					5 (3 motors)   
					5,240   
					5,270   
					5,445   
					7 
				Tables D: Air Turnover Heating/Cooling Unit with Filtration Performance Information   
					(For cooling applications, consult factory. Base Unit Weights do not account for inclusion of cooling coils or exclusion of heat exchanger.   
					Additional configurations are available upon request.)   
					AT-136   
					AT-248   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					Temp. Rise   
					Range (°F)   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					CFM   
					Motor (HP)   
					4,500 1.5 (1 motor)   
					240   
					240   
					240   
					450   
					450   
					450   
					49 to 93   
					25 to 46   
					19 to 35   
					2,425   
					2,505   
					2,520   
					22,000 5 (2 motors)   
					35,000 7.5 (2 motors)   
					45,000 10 (2 motors)   
					45,000 10 (2 motors)   
					240   
					520   
					560   
					560   
					750   
					10 to 32   
					14 to 26   
					12 to 26   
					12 to 31   
					6,190   
					6,345   
					6,575   
					6,730   
					9,000   
					5 (1 motor)   
					1,000   
					1,250   
					1,500   
					12,000 5 (1 motor)   
					AT-148   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					3,455   
					3,470   
					AT-254   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					10,000 5 (1 motor)   
					16,000 7.5 (1 motor)   
					240   
					240   
					450   
					750   
					22 to 42   
					14 to 43   
					40,000 5 (2 motors)   
					60,000 10 (2 motors)   
					65,000 15 (2 motors)   
					560   
					600   
					600   
					1,750   
					2,250   
					2,500   
					13 to 41   
					9 to 35   
					9 to 36   
					7,870   
					8,310   
					8,560   
					AT-154   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					AT-260   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					11,070   
					11,335   
					11,385   
					Temp. Rise   
					Range (°F)   
					14,000 5 (1 motor)   
					22,000 7.5 (1 motor)   
					30,000 10 (1 motor)   
					30,000 10 (1 motor)   
					240   
					240   
					520   
					560   
					450   
					750   
					1,000   
					1,250   
					16 to 30   
					10 to 32   
					16 to 31   
					17 to 39   
					4,080   
					4,140   
					4,210   
					4,420   
					CFM   
					Motor (HP)   
					54,000 7.5 (2 motors)   
					61,000 10 (2 motors)   
					74,000 15 (2 motors)   
					600   
					720   
					720   
					3,000   
					4,000   
					4,000   
					10 to 51   
					11 to 61   
					9 to 50   
					AT-236   
					AT-272   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					9,000 1.5 (2 motors)   
					18,000 5 (2 motors)   
					24,000 5 (2 motors)   
					240   
					240   
					520   
					450   
					750   
					1,000   
					25 to 46   
					12 to 39   
					20 to 39   
					4,145   
					4,240   
					4,270   
					62,000 7.5 (2 motors)   
					88,000 15 (2 motors)   
					100,000 15 (2 motors)   
					600   
					720   
					720   
					3,000   
					4,500   
					4,500   
					9 to 45   
					8 to 47   
					7 to 42   
					12,160   
					12,385   
					12,515   
					AT-242   
					Output   
					(MBH)   
					Minimum Maximum   
					Output   
					(MBH)   
					Base Unit   
					Weight   
					(lbs.)   
					Temp. Rise   
					Range (°F)   
					CFM   
					Motor (HP)   
					21,000 5 (2 motors)   
					31,000 7.5 (2 motors)   
					31,000 7.5 (2 motors)   
					240   
					520   
					560   
					750   
					1,000   
					1,250   
					11 to 33   
					16 to 30   
					17 to 37   
					5,240   
					5,270   
					5,445   
					Installation Code and Annual Inspections:   
					All installations and service of ROBERTS GORDON® equipment must be performed by a contractor qualified in the installation and ser-   
					vice of equipment sold and supplied by Roberts-Gordon and conform to all requirements set forth in the ROBERTS GORDON® manuals   
					and all applicable governmental authorities pertaining to the installation, service and operation of the equipment. To help facilitate   
					optimum performance and safety, Roberts-Gordon recommends that a qualified contractor annually inspect your ROBERTS GORDON®   
					equipment and perform service where necessary, using only replacement parts sold and supplied by Roberts-Gordon.   
					Further Information: Applications, engineering and detailed guidance on systems design, installation and equipment performance is   
					available through ROBERTS GORDON® representatives. Please contact us for any further information you may require, including the   
					Installation, Operation and Service Manual.   
					This product is not for residential use.   
					This document is intended to assist licensed professionals in the exercise of their professional judgement.   
					Roberts-Gordon, LLC   
					1250 William Street   
					P.O. Box 44   
					Buffalo, NY 14240-0044 USA   
					Telephone: 716.852.4400   
					Fax: 716.852.0854   
					European Office:   
					Roberts Gordon Europe Limited   
					Telephone: +44(0)121 506 7700   
					Fax: +44(0)121 506 7701   
					Toll Free: 800.828.7450   
					
					© 2007 Roberts-Gordon, LLC All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form   
					or by any means – graphic, electronic, or mechanical, including photocopying, recording, taping, or information   
					storage and retrieval systems – without written permission of Roberts-Gordon, LLC.   
					Printed in U.S.A.   
					CATDSGNA   
					2M 1107 Orig   
				 |