IMPORTANT!  
CAUTION: Please read this entire manual before you install and use your new room heater. For your safety, follow these  
installation, operation and maintenance instructions exactly, without deviation. Failure to follow these instructions may  
result in property damage, bodily injury, or even death. If this appliance is not properly installed, a house fire may result.  
Contact your local building or fire officials about restrictions and installation inspection requirements in your area.  
1. If using an older chimney, it must be inspected for adequate serviceability. Refer to Chimney Inspection on page 11 of  
this manual.  
2. The minimum clearances must be maintained for all combustible surfaces and materials, including furniture, carpet,  
drapes, clothing, wood, papers, etc. Do not store firewood within this clearance space. Failure to maintain clearances to  
all combustible materials may result in a house fire.  
3. This appliance requires non-combustible floor protection as outlined in this manual (see Floor Protection on page 9 for  
additional information).  
4. Minimum ceiling height must be 7 feet (213 cm) (measured from base of appliance to ceiling).  
5. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE THAT IS CONNECTED TO ANOTHER APPLIANCE.  
6. Do not connect this appliance to air ducts or any air distribution system.  
7. PREVENT CREOSOTE FIRE: Inspect and clean chimney frequently. Under certain conditions of use, creosote build-  
up can occur rapidly. Inspect chimney connector and chimney twice monthly and clean if necessary. Using green or in-  
adequately seasoned wood can greatly increase creosote build-up. Use dry wood only to minimize creosote build-up.  
8. USE SOLID WOOD FUEL ONLY: This appliance is approved for burning dry, seasoned, natural wood only. CAU-  
TION: BURN UNTREATED WOOD ONLY. DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS, SUCH AS  
GASOLINE, NAPHTHA OR ENGINE OIL.  
9. Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen  
up” a fire in this heater. Keep all such liquids well away from heater while it is in use.  
10. DO NOT OVERFIRE: If heater or chimney connector glows, you are overfiring. Overfiring this appliance could cause  
a house fire. Overfiring is a condition where the appliance is operated at temperatures above its design capabilities.  
Overfiring can be caused by improper installation, improper operation, lack of maintenance or improper fuel usage.  
Damage caused from overfiring is NOT covered under the manufacturer’s limited warranty.  
11. NEVER LEAVE AN UNATTENDED WOODSTOVE BURNING ON HIGH. Operation of the woodstove with the  
primary air control at its highest burn rate setting for extended periods can cause dangerous overfiring conditions. The  
primary air control should only be positioned at the highest setting during start-up procedures and for short durations.  
If leaving the woodstove unattended, ensure that the primary air control is set to the low or medium low range.  
12. Use the metal ash drawer only to dispose of ashes.  
13. IN THE EVENT OF A COMPONENT FAILURE, USE ONLY COMPONENTS PROVIDED BY THE MANUFAC-  
TURER AS REPLACEMENT PARTS.  
14. Burning any kind of fuel uses oxygen from the dwelling. Be sure that you allow an adequate source of fresh air into the  
room where the woodstove is operating (see Ventilation and Fresh Air on page 9).  
15. CAUTION: HOT WHILE IN OPERATION. An appliance hot enough to warm your home can severely burn anyone  
touching it. Keep children, clothing and furniture away. Contact may cause skin burns. Do not let children touch the  
appliance. Train them to stay a safe distance from the unit.  
16. Do not operate this appliance without the firebox baffle brick properly installed.  
17. Build fires directly upon the brick surface inside the woodstove. Do not use grates, irons or any other method to elevate  
the fire.  
SAVE THESE INSTRUCTIONS.  
See the listing label located on the back of woodstove (or see Safety on page 18).  
It is highly recommended to install a smoke detector in the home when installing a wood stove.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
Congratulations on the purchase of your new woodstove manufactured by Wolf Bavaria in  
Germany.  
When you purchased your new woodstove, you joined the ranks of thousands of concerned individuals whose answer to  
their home heating needs reflects their concern for aesthetics, efficiency and our environment. We extend our continued  
support to help you achieve the maximum benefit and enjoyment available from your new German woodstove.  
It is our goal at Wolf Bavaria to provide you, our valued customer, with an appliance that will provide you with years of  
trouble-free warmth and pleasure.  
Thank you for selecting a Wolf Bavaria Products woodstove as the answer to your home heating needs.  
Sincerely,  
All of us at Wolf Bavaria  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
TABLE OF CONTENTS  
1.  
Planning Your Installation  
7
1.1  
1.2  
1.3  
1.4  
1.5  
1.6  
1.7  
Questions to Ask Local Building Officials  
Smoke Detectors  
7
7
7
8
9
9
9
Selecting a Location  
Clearance from Combustible Walls  
Floor Protection  
Ventilation  
Fresh Air  
2.  
Installation  
10  
2.1  
2.2  
2.3  
2.4  
2.5  
2.6  
2.7  
2.8  
Installing Marble Accents  
Baffle Bricks  
10  
10  
11  
11  
11  
12  
12  
14  
Types of Chimneys  
Acceptable Connector Pipe for Installations  
Chimney Inspection  
Chimney Height Requirements  
Draft Requirements  
Combustible Wall Chimney Connector Pass-Throughs  
3.  
User’s Guide  
Hand Protection  
Technical Data and Dimensions  
Delivery  
Unpacking  
Acceptable Fuel  
15  
3.1  
3.2  
3.3  
3.4  
3.5  
15  
15  
17  
17  
18  
4.  
5.  
Safety (Please read, very important!!!)  
Fresh Air Supply  
Operating Your Woodstove  
Regulating the Heat  
Door  
18  
19  
20  
20  
21  
6.  
6.1  
6.2  
7.  
Heating Operation  
First Use  
Starting a Fire  
Environmentally Safe Heating  
Adding Wood  
Maximum Fuel Supply  
Putting the Fire Out  
Heating During Transition Periods  
22  
7.1  
7.2  
7.3  
7.4  
7.5  
7.6  
7.7  
22  
22  
23  
23  
23  
23  
23  
8.  
8.1  
8.2  
Cleaning and Maintenance  
Door Gasket Seal  
Cleaning the Woodstove  
24  
24  
24  
9.  
Troubleshooting  
25  
9.1  
9.2  
9.3  
Poor Draft Conditions  
25  
25  
25  
Woodstove does not give off enough heat  
Woodstove gives off too much heat  
10. Important  
11. Fire Safety (Please read – VERY IMPORTANT!!!)  
25  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
12. Warranty  
13. Replacement Parts List  
13.1 Replace Tiles  
25  
26  
26  
13.2 Replace Glass  
26  
26  
27  
28  
13.2.1  
13.2.2  
13.2.3  
Replace glass and door handle on Etna, Vesuv and Elbrus  
Replace glass and door handle on Meru  
Replace baffel bricks on Etna, Vesuv, Elbrus and Meru  
Testing/Listing  
Appliance Type: Solid Fuel Room Heater  
U.S. Test Standard: UL 1482  
Canadian Test Standard: CAN/ULC-S627  
EPA Exemption Certification  
Packaging List  
(1) Installation / Operation / Instruction Manual  
(1) Warranty  
(1) Set of Baffle Bricks  
(1) Set of Tiles or Soap Stone  
(1) Glove  
(1) Lever for Secondary Air  
Using this Manual  
Please read and carefully follow all of the instructions found in this manual. Please pay special attention to the safety  
instructions provided in this manual. The Homeowner’s Care and Operation Instructions included here will assure  
that you have many years of dependable and enjoyable service from your appliance.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
1. Planning Your Installation  
1.1 Questions to Ask Local Building Officials  
A correct installation is critical and imperative for reducing fire hazards and perilous conditions that can arise when wood  
burning appliances are improperly installed. The installer must follow all of the manufacture’s instructions.  
The installation of a wood burning appliance must conform to local codes and applicable state and federal requirements.  
Familiarity with these requirements before installation is essential. Important considerations to discuss with local building  
officials include:  
Local restrictions?  
Is a permit required – cost?  
(You may wish to contact your insurance company to ask if they require this.)  
Is outside combustion air required?  
Rooms where the installation is not allowed?  
1.2 Smoke Detectors  
Since there are always several potential sources of fire in any home, we recommend installing smoke detectors. If possible,  
install the smoke detector in a hallway adjacent to the room (to reduce the possibility of occasional false activation from the  
heat produced by the woodstove). If your local code requires that a smoke detector be installed within the same room, you  
must follow the requirements of your local code. Check with your local building department in your area.  
Note – This appliance is NOT approved for installation in a manufactured (mobile) home.  
1.3 Selecting a Location  
The design of your home and where you place your woodstove will determine its value as a source of heat. A woodstove  
depends primarily on air circulation (convection) to disperse its heat. Therefore, a central location is often best. There are  
other practical considerations, which must be considered before a final selection of location is made.  
?
?
?
?
?
?
?
Existing Chimneys  
Wood Storage  
Aesthetic Considerations  
Roof Design (Rafter Locations & Roof Pitch)  
Room Traffic  
Proximity to Combustibles  
Electrical Wiring  
The installation of this stove will require some research. Once your options are determined, consult with your local building  
department as to the necessary installation requirements for your area (Is a building permit required, Rooms where installa-  
tion may not be allowed, etc.).  
Warning: Check all local building and safety codes before installation. The installation instructions and  
appropriate code requirements must be followed exactly and without compromise. Alterations to the  
stove are not allowed. Do not connect the stove to a chimney system serving another stove, appliance, or  
any air distribution duct. Failure to follow these instructions will void the manufacturer’s warranty.  
If you plan to vent your woodstove into an existing masonry chimney, have it inspected by a local fire marshal or qualified  
installer. Remember that a woodstove’s performance is heavily influenced by the chimney and its location on the roof. An  
oversized flue may not provide effective draw, and a flue liner may be required (see Draft Requirements, page 12). Consult  
your dealer or qualified installer before final selection is made.  
This woodstove requires pre-installation, including the preparation of the floor and appropriate hearth pad for acceptance of  
outside air (if applicable), and modifications for flue and chimney.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
1.4 Clearance from Combustible Walls  
WARNING: IT IS VERY IMPORTANT THAT YOU OBSERVE THE MINIMUM CLEARANCES.  
There are listed clearances for your stove which were determined in a laboratory test, using various “classes” of stove pipe  
or chimney. Minimums are first established for the stove itself and then increased, based on how much heat is transferred  
by each class of pipe.  
Residential Standard (not approved for manufactured [mobile] homes)  
Using single wall pipe connector to the top of the woodstove.  
Clearances – USA & Canada (inches / millimeters)  
A:  
B:  
18 / 460  
15 / 380  
C:  
D:  
18 / 460  
15 / 380  
E:  
18 / 460  
B
C
D
A
E
D
PROTECTED WALL CLEARANCE  
If the woodstove is installed adjacent to a protected wall system, the variance must be approved by your local building  
official. Normally, the protected wall system is defined as a non-combustible material, with a minimum of 1” air space  
behind it. Check your local building codes or consult a qualified installer (Ref. NFPA 211).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
1.5 Floor Protection  
This appliance requires a non-combustible floor protection to protect against burning embers. If the floor is to be stone, tile,  
brick, etc., it must be mortared or grouted to form a continuous, non-combustible surface. If a chimney connector extends  
horizontally over the floor, protection must cover the floor under the connector and at least 2” (51 mm) to either side.  
The floor protection must extend completely beneath the woodstove and to the front, sides, and rear as indicated.  
USA REQUIREMENTS  
16” minimum to the front of the glass door  
8” (203 mm) minimum beyond the sides of the door opening  
0” minimum to the back of the stove body  
CANADA REQUIREMENTS  
18” (457 mm) minimum to the front of the glass door  
8” (203 mm) minimum beyond the sides of the door opening  
8” (203 mm) minimum to the back of the stove body  
1.6 Ventilation  
(Residential homes which do not require an outside air inlet). Ventilation is essential when using a solid fuel woodstove.  
The combustion process uses oxygen from inside the home, and it may be necessary to open a window or install a vent to  
provide fresh air in a house that is well insulated.  
1.7 Fresh Air  
In all manufactured homes and in many site-built residences (subject to local code), a woodstove may require outside air for  
combustion. A Ø120 mm outside air floor duct is available through your dealer.  
This woodstove can take in outside air directly through the base. This type of installation requires a hole through the floor  
protector and the use of an outside air floor duct to penetrate into the air space below the home.  
The possible effects of room air starvation, icing, exhaust fans, etc. and the need for adequate ventilation.  
The following is not mandatory, but may be included for information. Provision for outside combustion air may be neces-  
sary to ensure that fuel-burning appliances do not discharge combustion products into the house. Guidelines to determine  
the need for additional combustion air may not be adequate for every situation. If in doubt, it is advisable to provide addi-  
tional air.  
a) Outside combustion air may be required if:  
1. The solid-fuel-fired appliance does not draw steadily, smoke rollout occurs, fuel burns poorly, or back-drafts oc-  
cur, whether or not there is combustion present.  
2. Existing fuel-fired equipment in the house, such as fireplaces or other heating appliances, smell, do not operate  
properly, suffer smoke roll-out when opened, or back-draft, whether or not there is combustion present.  
3. Opening a window slightly on a calm (windless) day alleviates any of the above symptoms.  
4. The house is equipped with a well-sealed vapor barrier and tight fitting windows and/or has any powered devices  
that exhaust house air.  
5. There is excessive condensation on windows in the winter.  
6. A ventilation system is installed in the house.  
If these or other indications suggest that infiltration air is inadequate, additional combustion air should be provided from the  
outdoors. Outside combustion air can be provided to the appliance by the following means:  
1. Direct connection: appliances can only use direct connection of outside combustion air if they are certified for this  
type of installation. Installations shall comply with the manufacturer's instructions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
2. Indirect method: for an appliance not certified for direct connection of outside combustion air, the outside air is  
ducted to a point no closer than (12 in.) 300 mm from the appliance to avoid an adverse effect on the performance  
of the appliance.  
3. A mechanical ventilation system: if the house has ventilation system (air exchange or heat recovery):  
a. The ventilation system may be able to provide sufficient combustion make-up air for the solid-fuel-fired appli-  
ance.  
b. The household owner should be informed that the ventilation system might need to be re-balanced by a ventila-  
tion technician after installation of the appliance.  
NOTE: Because the base sits 1” (25.4 mm) off the floor, the outside air floor duct can be positioned along the front to rear  
center line under the pedestal, but as close to the opening in the base as location permits. The outside air floor duct opening  
must be protected from any possible obstructions, including loose floor insulation.  
2. Installation  
2.1 Installing Marble Accents  
Marble is a natural product, and, therefore, each piece will have its own unique characteristics. Marble can be scratched, so  
care should be taken to avoid putting heavy or rough objects (trivet/steamers) on the surface. If the marble should become  
scratched, the scratch may be removed or diminished by polishing it with jeweler’s rouge (which can be purchased at many  
hardware stores). Do not install the marble before allowing the paint to cure.  
The marble set consists of 2 pieces, a large piece which fits onto the stove top and a smaller piece which fits onto the ash  
lip, which is located below the fuel door.  
Install the marble gasket and marble as follows:  
1. Install gasket on stove top as shown in the illustration. The ceramic fiber blanket and strips (cerawool) which come  
with each unit must be placed under the marble to insulate it from high temperatures on top of the firebox. Do not  
place the marble directly on the top metal surface of the stove, or it will crack.  
2. Place top marble piece onto the gasket on stove top  
3. Place ash lip marble into recessed area on the stove ash lip (located below the fuel door).  
2.2 Baffle Bricks  
The baffle bricks are preinstalled by the manufacturer.  
IMPORTANT: The baffle bricks require periodic inspection and replacement for proper operation. If  
the baffle bricks are fractured or crumbling, they should be replaced. Do not operate this appliance  
without the baffle bricks being properly installed.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
2.3 Types of Chimneys  
The chimney is a vital part of your woodstove installation. A properly built masonry chimney or a properly installed, fac-  
tory built chimney will provide a consistent draft under a variety of weather conditions (a smoking woodstove is usually  
caused by a chimney problem). The minimum stove flue size is 6 inches (152 mm) in diameter, which is approximately 28  
square inches (711 square mm). The maximum flue size should be no more than three times the cross sectional area, or the  
size of the stove flue collar. In this case, that would be no larger than a 10 inch (254 mm) diameter stack, or approximately  
85 square inches (216 square cm) maximum.  
All chimneys must be installed as specified by local building codes and according to the chimney manufacturer’s instruc-  
tions (in the case of a factory built chimney). See the chimney manufacturer’s instructions for exact specifications. Factory  
built chimneys must comply with UL 103HT or ULC S629.  
2.4 Acceptable Connector Pipe for Installations  
For Standard Residential Clearances: 6” (152 mm) minimum, single wall, 25 gage minimum thickness, stove pipe is  
acceptable. Three (3) pre-drilled holes are provided in the flue collar for fastening the pipe securely to the woodstove. Use  
sheet metal screws for each section when connecting to the manufacturer’s transition piece, usually called a dripless con-  
nector, to join single wall pipe to the factory built chimney section.  
Minimum Flue Size: The required minimum diameter and area required for the flue size is 6” / 152 mm diameter, which is  
approximately 28 square inches / 711 square mm. The maximum flue size should be no more than three times the cross  
sectional area of the size of the 6” / 152 mm diameter flue collar. In this case, that would be no larger than 10” (254 mm) in  
diameter (area = approx. 85 sq. inches [216 sq. cm]).  
Connection To A Factory Built Chimney: This space heater is to be connected to a factory-built chimney, conforming to  
CAN / ULC – S629 Standard for 650°C Factory-Built Chimneys.  
2.5 Chimney Inspection  
Existing chimneys must be inspected before installing your woodstove. Consult your local building department for chimney  
code requirements. A masonry chimney must have a code approved liner. This liner must not have broken or missing  
pieces. Some non-code masonry chimneys may be brought up to code by being relined.  
(Consult your dealer or qualified chimney sweep). Factory built chimneys should also be inspected, first for creosote depos-  
its (which should be removed), and then for integrity of the stainless steel liner. Look for obvious bulges in the lining which  
may indicate the need to replace that section (use a bright flashlight). Also, inspect the attic to see that the chimney has  
proper clearance to combustible framing members. For interior masonry chimneys and most factory built chimneys, this  
must be a 2” (51 mm) air space clearance, which must not be filled with insulation or any other material. An exterior ma-  
sonry chimney must have a 1” (25.4 mm) air space clearance.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
Vapor Barrier At Chimney Penetration  
Install all venting components according to the vent manufacturer’s installation instructions. Ensure that there is an effec-  
tive vapor barrier at the location where the chimney penetrates the exterior of the structure. This can be accomplished by  
applying a non-hardening, waterproof sealant to the following components:  
?
?
?
Around the chimney at the point where the storm collar will meet the chimney, just above the flashing.  
Along the vertical seam of the chimney pipe, where it is exposed to the weather.  
On each nail head on the flashing.  
NOTE:  
On a flat or tarred and graveled roof, nail and seal the flat roof flashing to the roof on all sides with roofing com-  
pound. Do not put screws through the flashing into the chimney pipe.  
2.6 Chimney Height Requirements  
The chimney must be 3 feet (914 mm) above the level of the roof penetration and a minimum of 2 feet (610 mm) higher  
than any roof surface within 10 feet (305 cm) (see below). Check with your local building officials for any additional re-  
quirements for your area.  
Due to prevailing winds, local terrain, adjacent tall trees, a hill or ravine near the home, or adjacent structures, additional  
chimney height or a special chimney cap may be required to ensure optimum performance.  
To achieve a stable draft, the total flue height required (from the appliance to termination) is 12 to 15 feet (366 to 457 cm)  
minimum.  
2.7 Draft Requirements  
The stove appliance is merely one component of a larger system. The other equally important component is the venting  
system. This is necessary for achieving the required flow of combustion air into the forechamber and for safely removing  
unwanted combustion byproducts from the appliance. If the venting system’s design does not promote these ends, the sys-  
tem may not function properly. A poorly functioning venting system may create performance problems, as well as safety  
hazards (i.e. an oversized chimney may result in less than optimum performance. Installations into a large, masonry chim-  
ney may require a liner to improve performance). A draft test should read greater than .04” W.C. (inches water column) and  
less than .08” W.C.  
American National Standard Institute ANSI/NFPA 211-92, draft 1-7: A chimney or vent shall be so designed and con-  
structed to develop a flow sufficient to completely remove all flue and vent gases to the outside atmosphere. The venting  
system shall satisfy the draft requirements of the connected appliance in accordance with the manufacturer’s instructions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
2.8 Combustible Wall Chimney Connector Pass-Throughs  
Method A. 12” (305 mm) Clearance to Combustible Wall Member: Using a  
minimum thickness of 3.5” (90 mm) brick and a 5/8” (16 mm) minimum  
wall thickness clay liner, construct a wall pass-through. The clay liner must  
conform to ASTM C315 (Standard Specification for Clay Fire Linings) or  
its equivalent. Keep a minimum of 12” (305 mm) of brick masonry between  
the clay liner und wall combustibles. The clay liner shall run from the brick  
masonry outer surface to the inner surface of the chimney flue liner but not  
past the inner surface. Firmly grout or cement the clay liner in place to the  
chimney flue liner.  
Method B. 9” (229 mm) Clearance to Combustible Wall Member: Using 6”  
(152 mm) inside diameter, listed, factory-built Solid-Pak chimney section  
with insulation of 1” (25.4 mm) or more, build a wall pass-through with a  
minimum 9” (229 mm) air space between the outer wall of chimney length  
and wall combustibles. Use sheet metal supports fastened securely to wall  
surfaces on all sides, to maintain the 9” (229 mm) air space. When fastening  
support to chimney length, do not penetrate the chimney liner (the inside  
wall of the Solid-Pak chimney). The inner end of the Solid-Pak chimney  
section shall be flush with the inside of the masonry chimney flue and  
sealed with a non-watersoluble, refractory cement. Use this cement to also  
seal to the brick masonry penetration.  
Method C. 6” (152 mm) Clearance to Combustible Wall Member: Starting  
with a minimum 24 gage (.024 inch [.61 mm]), 6” metal chimney connec-  
tor, and a minimum 24 gage ventilated wall thimble which has two air  
channels of 1” ( 25.4 mm) each, construct a wall pass-through. There shall  
be a minimum 6” (152 mm) separation area containing fiber glass insula-  
tion, from the wall thimble, and cover its opening with a 24-gage minimum  
sheet metal support. Maintain the 6” (152 mm) space. There should also be  
a support sized to fit and hold the metal chimney connector. See that the  
support is fastened securely to wall surfaces on all sides. Make sure fasten-  
ers used to secure the metal chimney connector do not penetrate chimney  
flue liner.  
Method D. 2” (51 mm) Clearance to Combustible Wall Member: Start with  
a Solid-Pak listed factory built chimney section, at least 12” (305 mm) long,  
with insulation of 1” (25.4 mm) or more, and an inside diameter of 8” (2”  
[51 mm] larger than the 6” [152 mm] chimney connector). Use this as a  
pass-through for a minimum 24 gage single wall steel chimney connector.  
Keep Solid-Pak section concentric with and spaced 1” (25.4 mm) off the  
chimney connector by wall of steel metal support plates at both ends of  
chimney section. Cover opening with and support chimney section on both  
sides with 24 gage minimum sheet metal supports. See that the supports are  
fastened securely to wall surfaces on all sides. Make sure fasteners used to  
secure chimney section do not penetrate chimney flue liner.  
NOTES:  
1. Connectors to a masonry chimney, except for method B, shall extend in one continuous section through the wall  
pass-through system and the chimney wall, up to but not past the inner liner face.  
2. A chimney connector shall not pass through an attic or roof space, closet or similar concealed space, or a floor or  
ceiling.  
3. Where passage through a wall or partition of combustible construction is desired, the installation shall conform to  
CAN/CSA-B365.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
3. User’s Guide  
3.1 Hand Protection  
Please use a protective glove when opening the doors!!! You can then add wood while the handle is hot  
3.2 Technical Data and Dimensions  
VESUV  
ETNA  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
ELBRUS  
MERU  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
Heat Output  
Dimensions  
h x w x d  
Flue Diameter  
Center Height  
rear design  
Weight  
Area Heated  
(inner)  
Model  
(kW)  
8
(mm)  
(mm)  
150  
(mm)  
1250  
(kg)  
285  
(m3 )  
180  
1478 x 828x 636  
VESUV  
8
8
8
1478 x 992x 636  
1478 x 702x 619  
1024 x 598 x 473  
150  
150  
150  
1250  
1250  
858  
260  
290  
180  
180  
180  
ETNA  
ELBRUS  
MERU  
160 (ceramic)  
190 (stone)  
Chimney Data  
Average Wood Use – Single Load  
3-4 pieces of wood, 15-20% moisture  
Draft  
(Pa)  
10  
Average  
(cm2)  
Flue Gas  
(g/s)  
Flue Gas Heat  
(oC)  
(kg/h)  
2.6  
225  
7,41  
350  
Note: We reserve the right to make modifications in the interest of technical advances!  
Room Heating Capacity  
The room heating capacity has a nominal value of 8 kW and is to be calculated as follows, according to DIN 18 893, for  
rooms that do not have insulation that complies with the Heat Insulation Ordinance:  
For favorable heating conditions – calculated according to DIN 4701  
At less favorable heating conditions - 145 m³  
At unfavorable heating conditions - 98 m³  
For interval heating, with interruptions of more than 8 hours, the heating capacity is reduced by 25%.  
3.3 Delivery  
Damage can occur to the product during transport, even though the packaging appears to be undamaged upon visual inspec-  
tion. Therefore, it is important that you inspect the stove itself very carefully and report all damages within one week. In  
the event of obvious visual damage to the product or its packaging, make a note of this on the shipping papers before ac-  
cepting the merchandise.  
3.4 Unpacking  
All cardboard and synthetic materials are recyclable. Please dispose of these at your local  
recycling center. None of the wooden parts have been surface treated, and they can be used  
as heating materials for your woodstove. Very carefully open the packaging so that you do  
not damage anything. Prior to installation, make sure that the base construction can support  
the weight of the stove! Use only proper lifting aids with adequate support capacities to  
move your woodstove.  
Please do not stand on top of your woodstove; it is not designed to be used as a ladder or  
scaffolding.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18  
3.5 Acceptable Fuel  
Acceptable fuel sources are pieces of wood with a length of 30 cm (12”) and a diameter of 10 cm (4”), as well as wood  
briquettes.  
Only air-dried wood should be used. The burning of waste materials, in particular synthetic materials, is not permit-  
ted, according to federal laws regulating emissions. In addition, this causes damage to the fireplace and chimney. Air-  
dried wood will achieve a maximum water content of 30% after at least 1 year (soft woods) and/or 2 years (hard woods).  
Wood is not designed for continuous burning, i.e. heating the fireplace overnight with wood is not possible.  
4. Safety (Please read, very important!!!)  
?
?
?
Check on a regular basis to make sure that the woodstove has been attached to the chimney in compliance with  
all regulations.  
Carefully read the User’s Guide before you use your woodstove for the first time. This will provide you with  
information about how to safely operate your stove.  
During operation, the woodstove’s surface will become very hot. Pay attention, in particular, to children playing  
in the vicinity of the stove, as they are most likely to be at risk of injury. Keep small children away from the  
stove.  
?
?
Make sure that no combustible material is located in the vicinity of or on top of the woodstove.  
Keep the door to the fireplace closed at all times, even if the woodstove is not in operation (with the exception of  
the initial heating up cycle).  
?
?
?
?
Avoid overloading your woodstove by adding too much fuel at one time.  
Never use alcohol, gasoline or other illegal, fire accelerators to start your fire.  
No combustible elements should be located within the heat radiation area of your woodstove.  
Empty the ash drawer on a regular basis so that it never completely fills up with ashes. Otherwise, the air sup-  
ply to the woodstove will be blocked.  
?
?
?
Always slide the ash drawer all the way to the back, up to the stop position.  
Be sure to provide an adequate supply of fresh air to the woodstove. The stove consumes oxygen.  
Do not forget that a kitchen fan that is located in the same or an adjacent room can cause a vacuum situation,  
which results in a smoke build-up within the room. Make sure that you have a sufficient supply of fresh air.  
Never remove hot ashes. Store the ashes in a container that is fire-proof and not combustible.  
Always use the protective glove when operating the woodstove. Do not touch the stove with your bare hand  
when it is in operation.  
?
?
?
Do not store any combustible liquids in the vicinity of your woodstove!  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
5. Fresh Air Supply  
The woodstove can only be installed in rooms with a sufficient supply of fresh air intake for combustion purposes. This is  
true of rooms that have at least one exterior door or one window that can be opened. Rooms that are connected to the same  
fresh air network, i.e. rooms within the same residence or common areas, are also appropriate for installation.  
The woodstove requires  
approx. 40m³ fresh air per hour for combustion.  
With newer, well-insulated houses, and particularly with houses using  
mechanical air circulation, it is important to supply a sufficient amount of  
fresh air. Models ETNA, VESUV, ELBRUS and MERU have a central air  
intake that directly supplies sufficient air into the combustion process.  
Therefore, you can supply air through a connecting pipe. Fresh air that is  
supplied in this manner can be regulated on the woodstove with the primary  
or secondary air control levers.  
Central air connector  
with diameter of Ø  
120 mm; capable of  
withstanding tempera-  
tures up to 80o C.  
Important!  
Read the User’s Guide before you use your woodstove / fireplace for the first time, and do not forget to have your  
installation inspected by the local authorities before its first fire. Consult your local authorities for any regulations  
and other information.  
The location that is used to support the base of the woodstove must be horizontal and without any uneven spots.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20  
6. Operating Your Woodstove  
Etna, Elbrus und Vesuv  
6.1 Regulating the Heat  
Draft controls to regulate secondary air are located under the door on the  
right and left sides respectively. Pull the control towards you to open.  
.
1) Secondary Draft Control  
ash  
drawer  
1
MERU:  
Close  
Open  
Pull = Open  
Press = Close  
1
The secondary draft control lever regulates the amount of air that is needed to reburn exhaust gases that are produced in  
the fireplace during the wood burning process. A portion of this secondary air circulates from the top to the door and helps  
to keep the glass window clean.  
The fire intensity can be regulated with the secondary draft control lever.  
Creosote - Formation and Need for Removal - When wood is burned slowly, it produces tar and other organic vapors,  
which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue  
of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. If ignited, this creosote creates an ex-  
tremely hot fire. Burning wood, the chimney connector and chimney should be inspected at least once every two months  
during the heating season to determine if a creosote buildup has occurred.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21  
6.2 Door  
Caution: Use protective glove!!!  
When adding wood, pull the door handle up. The door can also be opened  
sideways so that you can clean the glass window. To do this, pull and re-  
lease the lever on the lower right side. After you have finished, remember to  
securely lock the door again by pressing it back in.  
Warning: Be careful in using the door. Never operate a stove with a  
broken glass door!!!  
MERU:  
A torsion spring is used to automatically close this door. This spring  
should never be disabled (refer to DIN 18891, Type 1). The door  
must be locked manually.  
door handle  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22  
6.3. Ash Drawer  
The ashes will fall down into the ash drawer after you pull on the grate lever  
several times. Do not forget that ashes will remain hot for several days in  
the ash drawer. Only use sheet metal ash containers to empty ashes out!  
A fire should never be started in the woodstove if the ash drawer is not  
in its proper position!  
ash drawer  
Disposal of Ashes - Ashes should be placed in a metal container with a  
tight fitting lid. The closed container of ashes should be placed on a  
noncombustible floor or on the ground, well away from all combustible  
materials, pending final disposal. If the ashes are disposed of by burial  
in soil or otherwise locally dispersed, they should be retained in the  
closed container until all cinders have thoroughly cooled.  
7. Heating Operation  
7.1 First Use  
Your new woodstove should not be used until after you have obtained approval from the proper authorities regarding its  
proper installation and conditions of use.  
The woodstove is designed to burn only wood, i.e. pieces of wood or wood briquettes.  
The wood must be dry (moisture ? 20%) and untreated. The burning of any other materials, such as chipboard, painted,  
laminated, impregnated, or synthetic coated wood, garbage, etc. is prohibited and causes irresponsible damage to the envi-  
ronment, as well as damage to your complete fireplace system.  
?
?
?
?
Have you removed all accessories from the ash pan and the fireplace?  
Check to make sure that no objects are located on top of the woodstove.  
Are the conventional / standard openings free and accessible?  
Keep the door to the fireplace partially open during the first lighting of your woodstove, as long as the fire has not gone  
out. The same applies to the ash pan. A special, heat-treated paint was used on your stove, and its hardening process is  
not completely “burned in” until after the first lighting. By keeping the door and ash pan partially open, this will pre-  
vent the gasket seals from adhering to the paint.  
Unpleasant smells that occur during the first lighting are normal. Provide good air ventilation to your room to re-  
move these odors.  
(!!! Heat until peak temperature is reached !!!)  
7.2 Starting a Fire  
It is important to engage the wood in a trouble-free combustion process as quickly and safely as possible. In order to ac-  
complish this, the wood should be layered in the woodstove as follows:  
Never use alcohol, gasoline or similar substances, including glossy paper, to light the fire. It does not burn properly,  
and its printed colors produce highly toxic elements in the fumes.  
?
Place newspaper or a solid fire starter, along with some kindling wood, in the fireplace. Stack the wood in a criss-  
crossed pile. Open the primary and secondary draft controls as far as possible. As long as the fire has not started burn-  
ing completely, you can leave the ash pan slightly opened. This will warm up the glass window and prevent soot coat-  
ing.  
?
?
As soon as the fire gets going, close the ash pan.  
For the next supply of fuel, spread out the burning embers in even layers and add approximately three (3) larger pieces  
of wood. After the wood starts to burn, you can close the primary draft control. The secondary draft control remains  
open.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
23  
?
?
After a period of time, as soon as the fire is burning well, it might seem as if the heat output is less. Regulate the burn-  
ing process first by the amount of wood in the stove. At the same time, the secondary draft can be reduced.  
The air supply for burning and for heat output is dependent upon the fireplace draft, moisture and size of wood.  
7.3 Environmentally Safe Heating  
Too much wood can result in an overheating situation. In this case, there is too much stress on the woodstove, and poor flue  
gas values result. If there is not enough wood, then the stove will not reach the required operating temperature. As a result,  
the wood does not burn up cleanly, and soot is built up on the glass and the fireclay walls. Therefore, fill your woodstove  
about halfway with wood pieces and replenish on a regular basis. Your woodstove is not a garbage burning incinerator. Use  
only wood or wood briquettes for fuel.  
7.4 Adding Wood  
Do not add wood until the flames have stopped blazing.  
First, open the draft controls completely, then slowly open the doors and add wood. Be sure to open the doors slowly to  
avoid a possible flame-up.  
Close the doors after you have added the wood. If the fire was almost burned out before you added more wood, keep the  
draft controls in a fully open position for approx. 5-10 minutes. Then move the controls to the center position for normal  
operation. After heating up and the addition of wood, soot can accumulate on the fireclay parts and glass window, but this  
will burn itself off again with the increase in fireplace temperature. If wet wood is used, a large amount of soot will accu-  
mulate on your woodstove. Therefore, do not burn wood with a moisture content of more than 20%.  
7.5 Maximum Fuel Supply  
The woodstove is designed for a maximum fuel supply, per load, of 2.5 kg of split wood or 1.5 kg of wood briquettes. If  
these maximum levels are exceeded, this may result in damage to your stove.  
7.6 Putting the Fire Out  
As soon as the fire has burned down and the wood is no longer glowing, close the primary and secondary draft air supplies.  
If the air supply controls are closed while the fire is still burning or the wood is still glowing, the resultant exhaust  
gas buildup in the woodstove can cause an explosion which breaks the glass window. The woodstove will continue to  
give off heat for some time. Otherwise, the stove will cool faster, due to the supply of fresh (cold) air, i.e. the thermal en-  
ergy escapes out the chimney.  
7.7 Heating during Transition Periods  
During transition periods (Spring / Fall), outside temperatures of over 16°C can cause a smoke buildup in the woodstove. If  
sufficient draft cannot be created with a startup fire at this temperature (i.e., rapid generation of high heat by quick burning  
of newspaper), so that the fumes are not completely removed, then you should abandon your plans for a fire. Use newspa-  
per as fuel for a startup fire. Add less wood during transition periods or wait longer before adding more wood.  
The fireplace should be filled with less fuel (wood) and operated at a higher setting of the primary draft control lever so that  
the existing fuel burns faster (in flames), which will stabilize the chimney draft. In addition, the wait time between adding  
wood for reheating should be extended. To avoid resistance in the fired, ashes should be carefully scraped off on a regular  
basis.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
24  
8. Cleaning and Maintenance  
Very important:  
All cleaning and maintenance work must only be performed on a compla2 l 531ool ondown firTj 23.732 0 TD (e.0362 Tc 0 Tw (c  
Top and bottom seals are  
fastened  
with  
three  
screws to bracket.  
Side seal is glued in  
with special stove  
cement.  
25  
9. Troubleshooting  
9.1 Poor Draft Conditions  
?
?
?
?
Is the chimney too short?  
Is the chimney or flue leaking?  
Is the flue protruding out from the chimney?  
Is the door from another fireplace that is connected to the same chimney, open?  
9.2 Woodstove does not give off enough heat  
?
?
?
?
?
?
Is the room too large?  
Are there too many ashes on the grate?  
Is the ash pan full?  
Is the flue obstructed?  
Are the primary and secondary draft air control levers closed?  
Is the connection between the stove and the chimney sealed or leaking?  
9.3 Woodstove gives off too much heat  
?
?
?
?
Are the primary and secondary draft air control levels open too far?  
Is the stove door closed properly? Is the ash pan completely closed?  
Is the chimney too tall?  
Have you added too much wood?  
10. Important  
Damages that occur as a result of improper operation are not covered under warranty.  
11. Fire Safety (Please read – VERY IMPORTANT!!!)  
Teach your children about fire safety, and, in particular, keep them as far away as possible from the woodstove while it is in  
operation. The heating process causes the top surface of the woodstove, as well as its operating elements, including the  
window and flue, to become extremely hot. Do not touch any of these parts without appropriate protective gear or tools,  
e.g. heat protection gloves. Never put laundry or other objects on the stove to dry. Objects that are not heat-resistant should  
never be placed on top of the woodstove or in the vicinity of the stove. Drying racks for drying clothing or similar items  
must be set up at a sufficient distance away from the heating device. Never heat and/or store flammable or explosive mate-  
rials, such as empty spray cans and similar objects, in or around the immediate fireplace area as this can cause an explosion.  
Do not wear loose or easily combustible clothing when starting the fire or adding wood. As long as your woodstove is in  
operation, do not work with easily combustible or explosive materials in the same or adjacent rooms.  
12. Warranty  
It is important for you to read the attached Warranty Statement before operating your woodstove. It con-  
tains information about the duties and responsibilities that must be met before a warranty claim can be  
made.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
26  
13. Replacement Parts List  
13.1 Replace Tiles  
13.2 Replace Glass  
13.2.1 Replace glass and door handle on Etna, Vesuv and Elbrus  
Glass Dimensions:  
Height:  
Width:  
Thickness:  
486.0mm  
394.4mm  
4.0mm  
Radius:  
420.0mm  
IMPORTANT: Replace glass only with glass from the manufacturer or distributor  
of this appliance.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
27  
13.2.2 Replace glass and door handle on Meru  
Glass Dimensions:  
Height:  
Width:  
Thickness:  
Radius:  
550.0mm  
350.0mm  
4.0mm  
504.0mm  
IMPORTANT: Replace glass only with glass from the manufacturer or distributor  
of this appliance  
Download from Www.Somanuals.com. All Manuals Search And Download.  
28  
13.2.3 Replace baffel bricks on Etna, Vesuv, Elbrus and Meru  
IMPORTANT: Replace baffel bricks only with baffel bricks from the manufac-  
turer or distributor of this appliance.  
We sincerely hope that your Wolf Bavaria woodstove provides you with many cozy  
hours of warmth and enjoyment.  
Manufactured by:  
Imported by:  
Frohnhof 9  
PO Box 120  
91580 Petersaurach  
Germany  
Pound Ridge, NY  
USA  
T: ++49 9802 951473  
F: ++ 49 9802 9589909  
T: 914 764 5679  
F: 614 764 0465  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Westinghouse Outdoor Ceiling Fan MR 72161 User Manual
Whirlpool Ice Maker 2180913 User Manual
Whirlpool Oven GY396LXPB02 User Manual
Whirlpool Oven R8700PXS User Manual
Whirlpool Washer 6LA932OXTWO User Manual
White Outdoor Tiller 217 310 190 User Manual
Wolf Griddle AGE24 User Manual
Xantrex Technology Battery Charger XC1524 User Manual
Zanussi Washer Dryer ZKH 2105 User Manual
Zebra Technologies Printer P110I User Manual