Vulcan Hart Oven VULCAN 36ESB User Manual

SERVICE MANUAL  
SALAMANDER ELECTRIC  
BROILER  
VULCAN -  
36ESB  
- NOTICE -  
This Manual is prepared for the use of trained Vulcan Service  
Technicians and should not be used by those not properly  
qualified.  
This manual is not intended to be all encompassing. If you have  
not attended a Vulcan Service School for this product, you should  
read, in its entirety, the repair procedure you wish to perform to  
determine if you have the necessary tools, instruments and skills  
required to perform the procedure. Procedures for which you do  
not have the necessary tools, instruments and skills should be  
performed by a trained Vulcan Service Technician.  
The reproduction, transfer, sale or other use of this Manual,  
without the express written consent of Vulcan, is prohibited.  
This manual has been provided to you by ITW Food Equipment  
Group LLC ("ITW FEG") without charge and remains the property  
of ITW FEG, and by accepting this manual you agree that you will  
return it to ITW FEG promptly upon its request for such return at  
any time in the future.  
A product of Vulcan-Hart  
3600 North Point Blvd Baltimore, MD 21222  
F45545 (0315)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SALAMANDER ELECTRIC BROILER - GENERAL  
GENERAL  
NOTE: Using accessory options, Salamander  
broilers can be mounted to the wall, over a range or  
placed onto an appropriate table top by using 4" legs.  
INTRODUCTION  
This manual is for the Vulcan and Wolf Electric  
Salamander Broilers. Procedures in this manual will  
apply to all models unless specified. Pictures and  
illustrations will be of model 36ESB unless otherwise  
noted.  
GRID POSITION AND HEAT  
CONTROL SETTING  
For detailed information refer to OPERATING THE  
BROILER and GRID ADJUSTMENT in the Installation  
& Operation Manual.  
All of the information, illustrations and specifications  
contained in this manual are based on the latest  
product information available at the time of printing.  
MODELS  
INSTALLATION, OPERATION AND  
CLEANING  
Vulcan  
36ESB-208  
36ESB-240  
36ESB-480  
For detailed installation, operation and cleaning  
instructions, refer to Installation & Operation Manual  
sent with each unit. The manual is also available  
SPECIFICATIONS  
3 PHASE MACHINE INFORMATION  
NOMINAL AMPS PER LINE WIRE  
240V  
OHMS per  
Element  
Model  
Total KW  
208V  
Y
480V  
Y
X
11.0  
Z
X
Y
Z
X
Z
4.9  
36ESB-208  
36ESB-240  
36ESB-480  
4.5  
4.5  
4.5  
18.9 11.0  
19.2  
25.6  
9.4 16.4 9.4  
4.9  
8.4  
102.4  
1. Values in the table are nominal. Tolerance is +5/-10%.  
2. Voltage values are @ 60Hz.  
NOTES:  
3. Resistance values (ohms) are @ 77° F.  
4. 2.25KW per element assembly (left or right).  
1 PHASE MACHINE INFORMATION  
NOMINAL AMPS PER LINE WIRE  
Model  
Total KW  
OHMS per Element  
208V  
21.6  
240V  
36ESB-208  
36ESB-240  
4.5  
4.5  
19.2  
25.6  
18.8  
1. Values in the table are nominal. Tolerance is +5/-10%.  
2. Voltage values are @ 60Hz.  
NOTES:  
3. Resistance values (ohms) are @ 77° F.  
4. 2.25KW per element assembly (left or right).  
Page 3 of 14  
F45545 (0315)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
SALAMANDER ELECTRIC BROILER - GENERAL  
TOOLS  
Standard  
Standard set of hand tools  
VOM with ability to measure micro amp current.  
VOM with minimum of NFPA-70E CAT III 600V,  
UL/CSA/TUV listed. Sensitivity of at least 20,000  
ohms per volt. Meter leads must also be rated at  
CAT III 600V.  
Clamp on type amp meter for measuring heating  
element current draw.  
Temperature tester (thermocouple type)  
F45545 (0315)  
Page 4 of 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SALAMANDER ELECTRIC BROILER - REMOVAL AND REPLACEMENT OF PARTS  
REMOVAL AND REPLACEMENT OF PARTS  
FRONT PANEL  
Disconnect the  
electrical power to the machine and  
follow lockout / tagout procedures.  
1. Remove screws that secure front panel to broiler.  
from front panel.  
3. Reverse procedure to install.  
Fig. 2  
4. Remove screws securing left side panel. Slide  
panel toward the front of broiler until panel clears  
front mounting area then remove the panel.  
Fig. 1  
LEFT SIDE PANEL  
Disconnect the  
electrical power to the machine and  
follow lockout / tagout procedures.  
1. Remove crumb tray.  
2. Remove FRONT PANEL.  
3. Position the rack assembly to access panel  
screws in the broiler opening area.  
Fig. 3  
5. Reverse procedure to install.  
Page 5 of 14  
F45545 (0315)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
SALAMANDER ELECTRIC BROILER - REMOVAL AND REPLACEMENT OF PARTS  
RIGHT SIDE PANEL  
Disconnect the  
electrical power to the machine and  
follow lockout / tagout procedures.  
1. Remove crumb tray.  
2. Remove FRONT PANEL.  
3. Remove screws securing plate stop to broiler.  
Fig. 5  
6. Remove screws securing right side panel to  
broiler. Slide panel toward the front of broiler until  
panel clears front mounting area then remove the  
panel.  
Fig. 4  
4. Pull knob off the handle on rack positioning  
bracket then remove plate stop.  
5. Position the rack assembly to access panel  
screws in the broiler opening area. Remove  
screws from this area and the front of panel.  
Fig. 6  
7. Reverse procedure to install.  
INFINITE SWITCH / 3 HEAT SWITCH  
Disconnect the  
electrical power to the machine and  
follow lockout / tagout procedures.  
1. Remove knob from switch.  
F45545 (0315)  
Page 6 of 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
SALAMANDER ELECTRIC BROILER - REMOVAL AND REPLACEMENT OF PARTS  
2. Remove washer nut securing switch to front  
panel.  
3. Loosen nuts to remove any remaining tension on  
springs.  
4. Access the bottom of broiler and remove springs  
from the lower arm casting and eye bolt.  
Fig. 7  
4. Note wire locations then disconnect wires from  
switch being replaced.  
Fig. 9  
5. Reverse procedure to install.  
HEATING ELEMENTS  
Disconnect the  
electrical power to the machine and  
follow lockout / tagout procedures.  
1. Remove crumb tray from broiler.  
2. Adjust rack assembly to the center position.  
Fig. 8  
5. Reverse procedure to install.  
6. Check for proper operation.  
3. Pull rack assembly out and access the rack stops  
on the left and right sides of the rack assembly.  
Allow enough clearance at the rear of rack  
assembly to rotate the rack stops to a horizontal  
position. If the rack assembly is pulled all the way  
out the rack assembly will engage the rack stops  
and prevent removal.  
RACK SPRINGS  
NOTE: Springs should be replaced in pairs for proper  
operation of the rack lift assembly.  
1. Remove crumb tray to access tension  
adjustment nuts from the front of broiler.  
2. Raise the rack lift assembly to its highest position  
on stop plate to relieve spring tension.  
Page 7 of 14  
F45545 (0315)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
SALAMANDER ELECTRIC BROILER - REMOVAL AND REPLACEMENT OF PARTS  
Fig. 13  
Fig. 10  
7. Note wire locations and disconnect wires from  
heating element.  
4. Grasp the rack assembly near the broiler, rotate  
both the rack stops horizontally and pull the rack  
assembly out enough for the rack assembly  
frame to clear the rack stops.  
Fig. 11  
5. Grasp the rack assembly and drip tray on each  
side to support the tray and remove from broiler.  
Fig. 14  
8. Reverse procedure to install.  
9. Check for proper operation.  
Fig. 12  
6. From inside broiler cooking area, remove screws  
securing heating element to broiler.  
F45545 (0315)  
Page 8 of 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SALAMANDER ELECTRIC BROILER - SERVICE PROCEDURES AND ADJUSTMENTS  
SERVICE PROCEDURES AND ADJUSTMENTS  
Certain procedures in this section require electrical test or measurements while  
power is applied to the machine. Exercise extreme caution at all times and follow Arc Flash  
procedures. If test points are not easily accessible, disconnect power and follow Lockout/Tagout  
procedures, attach test equipment and reapply power to test.  
1. Remove FRONT PANEL.  
INFINITE SWITCH TEST (208V/  
2. Reconnect power to machine.  
240V)  
3. Check input voltage at L3 and L2 on the switch  
terminals.  
Disconnect the  
4. Check for the correct output voltage at the output  
terminals for all knob settings of the switch.  
electrical power to the machine and  
follow lockout / tagout procedures.  
L3 Input -  
L2 Input -  
Knob Settings  
Output at  
Terminal(s)  
Output at  
Terminal(s)  
NOTE: Refer to AI3829 in WIRING DIAGRAMS for  
switch terminal locations.  
High  
Med  
Low  
1 & 3  
2
2
3
1. Remove FRONT PANEL.  
1
1
2. Connect a voltmeter to the output terminals H1  
and H2.  
5. If the voltages are not correct, replace the switch  
as outlined under INFINITE SWITCH / 3 HEAT  
3. Reconnect power to machine.  
4. Turn knob to the desired setting.  
5. Compare the percentage of ON time to OFF time.  
NOTE: ±7.5% tolerance allowable.  
RACK SPRING TENSION  
ADJUSTMENT  
Knob  
Setting  
Seconds  
on  
Seconds  
off  
% on Time  
1. Access the springs on the bottom of broiler.  
Hi  
100  
48  
37  
28  
7
ALL  
15  
8
0
2. Tighten nut to adjust rack spring tension. Adjust  
both springs equally so there is approximately  
3/4" of thread above the nut. If additional rack  
spring tension is required, tighten each nut an  
additional 2-3 turns.  
Med.  
15  
14  
24  
33  
Low  
Med. Low  
Very Low  
7
3
3. Check for proper operation.  
6. If the percentage is not correct, replace the  
switch as outlined under INFINITE SWITCH / 3  
3 HEAT SWITCH TEST (480V)  
Disconnect the  
electrical power to the machine and  
follow lockout / tagout procedures.  
NOTE: Refer to AI3830 in WIRING DIAGRAMS for  
switch terminal locations.  
Page 9 of 14  
F45545 (0315)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
SALAMANDER ELECTRIC BROILER - SERVICE PROCEDURES AND ADJUSTMENTS  
1) If both measured values are  
approximately the same as listed in the  
machine information table, then  
heating elements are functioning  
properly.  
2) If one or both of the measured values  
do not agree with the values listed in  
the machine information table, then  
heating element is malfunctioning.  
Turn broiler control switches OFF.  
Disconnect the  
electrical power to the machine and  
follow lockout / tagout procedures.  
Fig. 15  
HEATING ELEMENTS TEST  
a. Install a replacement heating  
element then proceed to step 2.  
C. If unable to check current draw, a resistance  
check (ohms) at heating element terminals  
may indicate a malfunctioning element.  
Disconnect the  
electrical power to the machine and  
follow lockout / tagout procedures.  
1) Remove lead wires from the heating  
element and check resistance. See  
machine information tables under  
resistance values at room  
NOTE: On 208V/240V broilers, the two heat controls  
are Infinite load switches; On 480V broilers, the two  
heat controls are 4 Position 3 Heat switches.  
1. Access the HEATING ELEMENTS.  
2. Reconnect power to machine.  
temperature.  
a. If resistance is incorrect, install a  
replacement heating element.  
3. Set broiler heat control switches to the highest  
setting.  
b. If resistance is correct, heating  
element has tested okay. If  
4. Measure the voltage at the heating element  
terminals and verify it against the data plate  
voltage.  
heating element is still suspect,  
5. Check broiler for proper operation.  
A. If voltage is incorrect, see  
B. If voltage is correct, check current draw  
(amps) through the heating element lead  
wires at the X and Z phases on the outlet  
side of the broiler terminal block. The X  
phase value is the current draw for the left  
element and the Z phase value is the current  
draw for the right element.  
See machine information tables under  
values and the appropriate 208/240V -  
connections.  
NOTE: Checking current draw is the preferred  
method over a resistance check when a clamp on type  
amp meter is available.  
F45545 (0315)  
Page 10 of 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SALAMANDER ELECTRIC BROILER - ELECTRICAL OPERATION  
ELECTRICAL OPERATION  
COMPONENT FUNCTION  
Infinite Load Switch . . . Two switches independently control the left and right heating elements on 208V and 240V  
models. Depending on switch setting, provides a range of ON time from 7% to 100%.  
3 Heat, 4 Position  
Two switches independently control the left and right heating elements on 480 volt  
Switch . . . . . . . . . . . . . . . models. Provides approximately 100% of total available power of 4.5 KW with both  
switches set to HI position, 50% at MED position, 25% at LO position, and 0% at the OFF  
position.  
Heating Element  
Provides heat for broiling food product. There are 2 element assemblies per broiler.  
Assemblies . . . . . . . . . .  
Terminal Block . . . . . . . Provides connections for supply voltage to the broiler.  
SEQUENCE OF OPERATION  
NOTE: On 208V/240V broilers, the two heat controls are Infinite load switches; On 480V broilers, the two heat  
controls are 4 Position 3 Heat switches.  
1. Conditions  
A. Broiler connected to correct supply voltage.  
B. Building circuit breakers ON (power to machine).  
C. Broiler heat control switches are OFF.  
D. Broiler at room temperature.  
2. Broiler heat control switches are turned to desired heat setting.  
A. Power to heating elements.  
3. Broiler heat control switches reach desired heat setting.  
A. Power removed from heating elements.  
4. Broiler heat control switches drop below desired heat setting.  
A. Broiler heat control switches will continue to cycle until turned to OFF or power is removed from broiler.  
Page 11 of 14  
F45545 (0315)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
SALAMANDER ELECTRIC BROILER - ELECTRICAL OPERATION  
208/240V - WIRING DIAGRAM  
Fig. 16  
F45545 (0315)  
Page 12 of 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SALAMANDER ELECTRIC BROILER - ELECTRICAL OPERATION  
480V - WIRING DIAGRAM  
Fig. 17  
Page 13 of 14  
F45545 (0315)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SALAMANDER ELECTRIC BROILER - TROUBLESHOOTING  
TROUBLESHOOTING  
TROUBLESHOOTING  
SYMPTOM  
POSSIBLE CAUSES  
1. No power to broiler.  
2. Infinite (208V/240V) or 3 heat switches (480V) are OFF or  
malfunctioning.  
No heat.  
3. Heating elements inoperative or malfunctioning.  
Cooking problems (product not done/  
overdone).  
1. Refer to Installation & Operation Manual for recommended grid  
position and heat control switch settings .  
F45545 (0315)  
Page 14 of 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   

Taylor Thermometer 1446 User Manual
Thermador Cooktop GGN30 User Manual
Tiger Robotics PMS280C User Manual
Toastmaster Coffeemaker TCM4B User Manual
Toshiba Automobile Parts LF470 User Manual
Toshiba CRT Television 26HF66 User Manual
Tricity Bendix Electric Pressure Cooker RE50GC User Manual
Tripp Lite Power Supply SUPT80KX User Manual
Uniden Scanner BC250D User Manual
Wagner SprayTech Paint Sprayer GA 250AL User Manual