U Line Refrigerator CLR1215 User Manual

QUICK START GUIDE  
1000 Series CLR1215 115 V / 60 Hz  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
Contents  
1
Model List  
2
Safety and Warning  
Environmental Requirements  
Water Hookup  
Drain  
2
3
5
7
Door Swing  
8
General Installation  
Control Operation  
First Use  
9
9
9
Ice  
10  
11  
Sabbath Mode  
Warranty  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
Model List  
This guide provides the basics to get you started. Looking for more information? Visit u-line.com to view detailed User Guides  
for all U-Line products.  
Clear Ice  
U-CLR1215S-00A  
U-CLR1215S-40A  
U-CLR1215INT-00A  
U-CLR1215INT-40A  
U-CLR1215B-00A  
U-CLR1215B-40A  
U-CLR1215W-00A  
U-CLR1215W-40A  
Outdoor Series  
U-CLR1215RSOD-00A  
U-CLR1215RSOD-40A  
scan this QR code to view all user guides online.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
Safety and Warning  
Environmental Requirements  
This unit is designed to operate between 50°F (10°C) and  
100°F (38°C). Higher ambient temperatures may reduce  
the unit’s ability to reach low temperatures and/or reduce  
ice production on applicable models.  
NOTICE  
PLEASE READ all instructions before installing,  
operating, or servicing the appliance.  
Use this appliance for its intended purpose only and follow  
these general precautions with those listed throughout this  
guide:  
For best performance, keep the unit out of direct sunlight  
and away from heat generating equipment.  
In climates where high humidity and dew points are  
present, condensation may appear on outside surfaces.  
This is considered normal. The condensation will  
evaporate when the humidity drops.  
SAFETY ALERT DEFINITIONS  
Throughout this guide are safety items labeled with a  
Danger, Warning or Caution based on the risk type:  
DANGER  
!
CAUTION  
!
Danger means that failure to follow this safety  
statement will result in severe personal injury or  
death.  
Damages caused by ambient temperatures of  
40°F (5°C) or below are not covered by the  
warranty.  
WARNING  
!
Warning means that failure to follow this safety  
statement could result in serious personal injury  
or death.  
CAUTION  
!
Caution means that failure to follow this safety  
statement may result in minor or moderate  
personal injury, property or equipment damage.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
Do not use Teflon tape or joint compound on the  
water fitting. The rubber washer provides an  
adequate seal. Other materials could cause  
blockage of the valve.  
Water Hookup  
INDOOR MODELS  
PREPARE PLUMBING  
Please use the braided stainless steel water supply line  
which comes attached. The water line is fitted with a  
standard 1/4" (6.35 mm) compression fitting.  
Failure to follow recommendations and  
instructions may result in damage and/or harm,  
flooding or void the product warranty.  
WARNING  
!
CAUTION  
!
Prior to installation, determine if this product  
contains a gravity style drain or factory installed  
drain pump. Products without a drain pump may  
only use a gravity style drain. Failure to connect  
water supply or drain line connections properly  
may result in water leakage, personal injury,  
and/or property damage. Disconnect power and  
turn off water to the unit before attempting to  
alter these connections. These connections are  
the responsibility of the owner and must be  
connected per local plumbing code. If you are  
uncertain of how to safely and properly install  
this product, contact a licensed plumber.  
Turn off water supply and disconnect electrical  
supply to unit prior to installation.  
1. Turn off water supply and disconnect electrical supply  
to product prior to attempting installation.  
2. Locate the desired cold water supply location.  
3. Locate braided stainless steel  
water supply line and  
connect to your cold water  
supply. The water line should  
be looped into 2 coils. This  
will allow the unit to be  
Water Supply Connection  
CAUTION  
!
removed for cleaning and  
servicing. However, make  
certain that the tubing is not pinched or damaged  
during installation.  
Review, obey, and understand the local  
plumbing codes before you install your unit.  
Connect to the cold water supply. The water  
pressure should be between 20 and 120 psi. The  
water line MUST have a shut-off valve on the  
supply line.  
4. Turn on water and check for leaks.  
CAUTION  
!
Do not use any plastic water supply line. The line  
is under pressure at all times. Plastic may crack  
or rupture with age and cause damage to your  
home.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
5. Route water supply line in cable clamp and secure with  
screw.  
Water Supply Connection  
CAUTION  
!
Review, obey, and understand the local  
plumbing codes before you install your unit.  
Connect to the cold water supply. The water  
pressure should be between 20 and 120 psi. The  
water line MUST have a shut-off valve on the  
supply line.  
CAUTION  
!
Do not use any plastic water supply line. The line  
is under pressure at all times. Plastic may crack  
or rupture with age and cause damage to your  
home.  
Do not use Teflon tape or joint compound on the  
water fitting. The rubber washer provides an  
adequate seal. Other materials could cause  
blockage of the valve.  
OUTDOOR MODELS  
PREPARE PLUMBING  
The water valve in this unit uses a standard 1/4"  
(6.35 mm) compression fitting.  
Failure to follow recommendations and  
instructions may result in damage and/or harm,  
flooding or void the product warranty.  
WARNING  
!
Prior to installation, determine if this product  
contains a gravity style drain or factory installed  
drain pump. Products without a drain pump may  
only use a gravity style drain. Failure to connect  
water supply or drain line connections properly  
may result in water leakage, personal injury,  
and/or property damage. Disconnect power and  
turn off water to the unit before attempting to  
alter these connections. These connections are  
the responsibility of the owner and must be  
connected per local plumbing code. If you are  
uncertain of how to safely and properly install  
this product, contact a licensed plumber.  
CAUTION  
!
Turn off water supply and disconnect electrical  
supply to unit prior to installation.  
Use caution when handling back panel. The  
edges could be sharp.  
1. Turn off water supply and disconnect electrical supply  
to product prior to attempting installation.  
2. Remove the grille/access panel in the front and the  
back panel.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
3. Locate water  
valve in the front  
of the unit and  
thread water  
supply line  
8. Install retaining clip.  
through.  
NOTICE  
Route the water  
supply line  
through the unit  
so it does not come into contact with any  
internal components other than the solenoid  
valve. Normal operation creates some vibration.  
A water supply line contacting an internal  
component or cabinet wall can cause excessive  
noise during operation or damage to the line.  
4. On the back panel,  
break away filler feature  
in bushing, with flat  
screwdriver.  
Drain  
Models ending in (-00A, -01A) will not be equipped with  
factory installed drain pump.  
Remove  
ZLWKꢀɠDWꢀ  
screwdriver  
Models ending in (-40A, -41A) will have the factory  
installed drain pump.  
5. Thread water line  
through back panel hole  
(with bushing).  
DRAIN CONNECTION  
CAUTION  
!
If your U-Line unit did not come with a factory  
installed drain pump you must use a gravity  
style drain connection. For assistance in  
determining if your unit has a pump please  
contact U-Line. The floor drain must be large  
enough to accommodate drainage from all  
attached drains. Follow these guidelines when  
installing drain lines to prevent water from  
flowing back into the ice maker storage bin and/  
or potentially flowing onto the floor, which may  
result in personal injury or property damage.  
6. Turn on water supply and check for leaks.  
7. Reinstall back panel and grille/front access panel.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
NOTICE  
CAUTION  
!
Drain can NOT be located directly below the unit.  
Unit has a solid base that will not allow the unit  
to drain below itself.  
Failure to connect water supply or drain line  
connections properly can result in personal  
injury and property damage. Gravity drain  
connections must be routed downward from the  
rest of the unit at the rate of 1/4" per foot (1 cm  
per 50 cm).  
There is a possibility that hose connections may  
have loosened during shipment.  
Verify all connections and fittings are free from  
leaks.  
FACTORY INSTALLED DRAIN PUMP  
If your drain line will run up to a stand pipe, disposal or  
spigot assembly, or does not otherwise meet the  
requirements for a gravity drain, you may have ordered a  
pre-installed U-Line P60 drain pump.  
GRAVITY DRAIN  
Normal  
Proper Drain  
See below for typical installations requiring a drain pump.  
With Trap  
Poor Drainage, Water Will Back Up  
Stand Pipe  
P60 Pump Required  
With Trap and Vent  
Proper Drain  
Waste  
6KXWꢁ2ɞ  
Valve  
A gravity drain may be used if:  
Cold  
Water  
Hot  
Water  
Drain line has at least a 1" drop per 48" (approximately  
2 cm drop per 100 cm) of run.  
Drain line does not create traps and is vented per local  
code.  
Waste  
1. Cut the pre-installed drain tube to length.  
2. Connect to your local plumbing per the local code.  
3. If necessary, insulate drain line to prevent  
condensation.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
Disposal Assembly  
P60 Pump Required  
Door Swing  
Air Gap  
(Optional Hook-Up)  
Wall  
Wall  
1/4" Min.  
(6 mm)  
2-1/8" Min.  
(54 mm)  
Waste  
Cold  
Water  
Hot  
Water  
6KXWꢁ2ɞ  
Valve  
90°  
90°  
Door Swing  
Door Swing  
Y-Branch Tailpiece  
P60 Pump Required  
Air Gap  
(Optional Hook-Up)  
Units have a zero clearance for the door to open 90°,  
when installed adjacent to cabinets.  
Waste  
6KXWꢁ2ɞ  
Stainless Steel and black and white models require 2-1/8"  
(54 mm) door clearance to accommodate the handle if  
installed next to a wall.  
Valve  
Cold  
Water  
Hot  
Water  
Integrated models require 1/4" (6 mm) clearance if  
installed next to a wall. Allow for additional space for any  
knobs or pulls installed on the integrated panel/frame.  
NOTICE  
The maximum lift for the P60 drain pump is  
10 feet. This must be done as close to the rear of  
the unit as possible.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
INSTALLATION  
General Installation  
1. Open the water supply valve in the main water source.  
LEVELING INFORMATION  
1. Use a level to  
confirm the unit is  
level. Level should  
be placed along top  
edge and side edge  
as shown.  
2. Plug in the power cord.  
3. Gently push the unit into position. Be careful not to  
kink the water supply line, the drain line, or entangle  
the power cord.  
4. Re-check the leveling, from front to back and side to  
side. Make any necessary adjustments. The unit’s top  
surface should be approximately 1/8" (3 mm) below  
the countertop.  
1
2. If the unit is not level, adjust the feet on the corners of  
the unit as necessary.  
Turn Foot to Adjust  
3. Confirm the unit is level after each adjustment and  
repeat the previous steps until the unit is level.  
INSTALLATION TIP  
If the room floor is higher than the floor in the cut-out  
opening, adjust the rear feet to achieve a total unit rear  
height of 1/8" (3 mm) less than the opening’s rear height.  
Shorten the unit height in the front by adjusting the front  
feet. This allows the unit to be gently tipped into the  
opening. Readjust the front feet to level the unit after it is  
correctly positioned in the opening.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
Control Operation  
Alert  
Up Down  
Light Power Clean LED  
CONTROL FUNCTION GUIDE  
FUNCTION  
COMMAND  
Press and release  
DISPLAY/OPTIONS  
ON/OFF  
Unit will immediately turn ON or OFF.  
Adjust ice thickness  
See “Ice” section  
The display will flash and then toggle from set point  
to temperature in unit.  
View temperature in unit Press  
together and release  
for five seconds  
and  
and  
Toggle between F/C  
Sabbath Mode  
Hold  
The display will beep and display unit temperature.  
See “Sabbath Mode” section  
Silent Mode (ice  
production suspended for Hold  
3 hours)  
and  
Display will show “OFF”.  
Clean Mode  
Hold  
for five seconds  
First Use  
Ice  
All U-Line controls are preset at the factory. Initial startup  
requires no adjustments.  
ICE CUBE THICKNESS ADJUSTMENT  
NOTICE  
Ice thickness adjustment should only be made  
one increment at a time. Allow ice maker  
production to stabilize for 24 hours before  
rechecking ice thickness.  
NOTICE  
U-Line recommends discarding the ice produced  
during the first two to three hours of operation  
to avoid possible dirt or scale that may dislodge  
from the water line.  
Ice cubes in any given batch will vary, so it is necessary  
to choose cubes from the sample area for comparison  
when making adjustments.  
When plugged in, the unit will begin operating under the  
factory default settings. If the unit was turned off during  
installation, simply press  
and the unit will immediately  
switch on. To turn the unit off, press  
seconds and release.  
and hold for 5  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
The ice cube thickness is factory set for best overall  
performance. The factory setting “0” is designed to  
maintain an ice bridge of approximately 1/16" to 1/8"  
(1.6 mm to 3.2 mm) under normal conditions, resulting in  
a dimple of approximately 1/4" to 1/2" (6.4 mm to  
12.7 mm) in depth. A fuller cube with less of a dimple  
results in a thicker ice bridge. As the ice bridge becomes  
thicker, the tendency for the cubes to stay together as a  
slab increases. A bridge thicker than 1/8" (3.2 mm) may  
cause cubes to overfill the ice bucket.  
Adjust ice thickness as follows:  
1. Press  
and hold for 5 seconds (display will show  
current settings).  
2. Press  
thinner.  
to make cube thicker or  
to make cube  
The total range of adjustment is -5 (thinest) to +5  
(thickest). If further adjustments are desired, repeat  
steps 1 and 2.  
DIMPLES  
L
Sabbath Mode  
ICE BRIDGE  
Power  
Ice Bridge and Dimples  
Cube Types  
U-Line Clear Ice Machine models are Star-K certified and  
can be used during the Sabbath. View a full list of Star-K  
1/4" TO 1/2"  
(6.4 mm to 12.7 mm)  
DIMPLE  
1/16" TO 1/8"  
(1.6 mm to 3.2 mm)  
ICE BRIDGE  
To prepare the unit for the Sabbath:  
1. Press  
and hold until the unit turns off.  
2. No new ice will form when the unit is off, but previously  
made ice will still be accessible/present for over 24  
hours. Pump equipped models will continue to remove  
water as needed even if the unit is off.  
THIN BRIDGE  
THICK BRIDGE  
LITTLE OR  
NO DIMPLE  
DEEP DIMPLE  
Sabbath Mode remains active until  
and the unit turns on.  
is pressed again  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
unit is completed and mailed back or electronically  
Warranty  
submitted to U-Line. This 30 day warranty does not  
apply to cosmetic damages. A proof of purchase may  
be required.  
U-LINE CORPORATION LIMITED WARRANTY  
1. U-Line Corporation (“U-Line”) warrants each U-Line  
product to be free from defects in materials and  
workmanship for a period of one year (two years on  
Modular 3000 Series) from the date of purchase.  
U-Line further warrants the sealed system (consisting  
of the compressor, condenser, evaporator, hot gas  
bypass valve, dryer, and connecting tube) in each  
U-Line product to be free from defects in materials and  
workmanship for a period of five years from the date of  
purchase.  
4. The following conditions are excluded from this limited  
warranty: use of cleaners other than the recommended  
stainless steel cleaners and U-Line Clear Ice Maker  
cleaner; installation charges; damages caused by  
disasters or acts of God, such as fire, floods, wind and  
lightning; damages incurred or resulting from shipping,  
improper installation, unauthorized modification, or  
misuse/abuse of the product; customer education  
calls; food loss and spoilage; door and water level  
adjustments (except during the first 30 days from the  
date of installation); defrosting the product; adjusting  
the controls; door reversal; and cleaning the  
condenser.  
2. During the initial one year warranty period (two years  
on Modular 3000 Series) for all U-Line products U-Line  
shall: (1) repair any product or replace any part of a  
product; and (2) for all Marine, RV and Domestic  
U-Line products sold and serviced in the United States  
(including Alaska and Hawaii) and Canada, U-Line  
shall be responsible for the labor costs performed by a  
U-Line authorized service company, incurred in  
connection with the replacement of any defective part.  
During years two through five of the warranty period  
for the sealed system, U-Line shall: (1) at U-Line’s  
option repair or replace any part of the sealed system;  
and (2) for all Marine, RV and Domestic U-Line  
products sold and serviced in the United States  
(including Alaska and Hawaii) and Canada, U-Line shall  
be responsible for the labor costs incurred in  
5. U-Line products are designed to operate in ambient  
temperatures between 50°F and 100°F unless  
otherwise noted in the product manual. Exposure to  
temperatures outside this range may cause  
degradation of performance and issues such as lower  
ice production or spoiled contents that are not covered  
under the terms of this warranty as a result of that  
exposure. U-Line product may not be subjected to  
temperatures below 40°F without following the  
winterization and vacation shutdown procedures in the  
user guide.  
connection with the replacement of any defective part  
of the sealed system. All other charges, including  
transportation charges for replacements under this  
warranty and labor costs not specifically covered by  
this warranty, shall be the responsibility of the  
6. U-Line’s Outdoor Limited Warranty, set forth in this  
Paragraph 6, shall apply to U-Line models deemed  
suitable for outdoor use by Underwriters Laboratory  
(“UL”) as noted in the U-Line Product Catalog, U-Line’s  
website and/or on the serial tag located inside the  
product.  
purchaser. This warranty extends only to the original  
purchaser of the U-Line product. The Product  
Registration Card included with the product should be  
promptly completed by you and mailed back to U-Line  
A. Outdoor product may come into contact with rain by  
virtue of outdoor use. Exposure to other sources of  
water shall also cause this warranty to be void,  
3. The warranty listed above does not apply to floor  
display models. The warranty for these models shall  
be 30 days from the date of retail purchase and only if  
U-Line’s Product Registration Card included with the  
including flooding of the area in proximity of the unit  
greater than 1/8" deep in water, hurricanes, splashing  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK START GUIDE  
u-line.com  
of pool water, or directing a spray from a hose or  
similar device into and around the unit.  
7. If a product defect is discovered during the applicable  
warranty period, you must promptly notify either  
U-Line at 8900 N. 55th Street, Milwaukee, Wisconsin  
53223 USA or at +1.800.779.2547 or the dealer from  
whom you purchased the product. In no event shall  
such notification be received later than 30 days after  
the expiration of the applicable warranty period. U-Line  
may require that defective parts be returned, at your  
expense, to U-Line’s factory in Milwaukee, Wisconsin,  
for inspection. Any action by you for breach of  
warranty must be commenced within one year after  
the applicable warranty period.  
8. THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL  
OTHER WARRANTIES, EXPRESS OR IMPLIED,  
INCLUDING ANY IMPLIED WARRANTY OF  
MERCHANTABILITY OR IMPLIED WARRANTY OF  
FITNESS FOR A PARTICULAR PURPOSE, ALL OF WHICH  
ARE DISCLAIMED. U-Line’s sole liability and your  
exclusive remedy under this warranty are set forth in  
the paragraphs above. U-Line shall have no liability  
whatsoever for any incidental, consequential or special  
damages arising from the sale, use or installation of  
the product or from any other cause whatsoever,  
whether based on warranty (express or implied) or  
otherwise based on contract, tort or any other theory  
of liability.  
Some states do not allow limitations on how long an  
implied warranty lasts or the exclusion or limitation of  
incidental or consequential damages, so the above  
limitations may not apply to you. This warranty gives you  
specific legal rights, and you may also have other rights  
which vary from state to state.  
Warranty 6/2014 Rev.G  
Copyright © 2014 U-Line Corporation. All Rights Reserved.  
Publication Number 30421 8/2014 Rev.A  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Teledex Conference Phone Pearl S User Manual
Thule Automobile Accessories 899xt User Manual
Toshiba Projection Television 50HX81 User Manual
Tripp Lite TV Cables S502 20N User Manual
Uniden Conference Phone FP203 User Manual
Viking Convection Oven VGSO100 User Manual
Viking Food Warmer F21200 EN User Manual
Vornado Electric Heater PVH User Manual
VTech Two Way Radio VT 1311 User Manual
Wagan Power Supply ower Inverter User Manual