| Electric Wall Fin   Model EWFB — Electric Wall Fin   October 2001   FIN-PRC003-EN   Download from Www.Somanuals.com. All Manuals Search And Download.   Contents   Features and Benefits   Dimensional Data   2 4 Wiring Diagrams   9 Mechanical Specifications   14   DBCT — Bottom Inlet (Top Discharge)   DBCF — Front Inlet (Top Discharge)   5" Deep x 7" High — 10-Gauge Extruded   Aluminum Front and Grille   RDBT-PD Architectural Draft Barrier   6" Deep x 5" High — 12-Gauge Extruded   Pedestal Mount   ASHDB — 8 through 20   5 1/2" Deep x 8" thru 20" High   Front Cover 16-Gauge Steel with   12-Gauge Extruded Aluminum Grille   FIN-PRC003-EN   3 Download from Www.Somanuals.com. All Manuals Search And Download.   Dimensional   Data   Model EWFB   Type DBF Wall Mounted (Bottom Louver)   15' (4.57 M) Length DBF and DBT Only Wall Mounted   Architectural Pedestal Heaters   Series DBT and DBF   100-250 Watt Per Foot   4 FIN-PRC003-EN   Download from Www.Somanuals.com. All Manuals Search And Download.   Dimensional   Data   Model EWFB   Type CB Wall Mounted   Typical Installation   Pedestal Heaters – Series CB   250 Watts Per Foot – Element Pedestals   FIN-PRC003-EN   5 Download from Www.Somanuals.com. All Manuals Search And Download.   Dimensional   Data   Model EWFB   Type DBCT and DBCF (Bottom Louver) Wall Mounted   NOTE:   Front covers available as standard through 15’.   Backplate available as option through 15’.   Typical Installation   Architectural Pedestal Heaters   Series DBCF, DBCT   6 FIN-PRC003-EN   Download from Www.Somanuals.com. All Manuals Search And Download.   Dimensional   Data   Model EWFB   Model RDBT-PD Pedestal Floor Mounted   Unit Length   Dimension “A”   Feet   Dimension “A”   Meters   0.61   2 Ft.   3 Ft.   0.91   4 Ft.   1.22   5 Ft.   1.52   6 Ft.   1.83   7 Ft.   2.13   8 Ft.   2.44   9 Ft.   2.74   10 Ft.   3.05   FIN-PRC003-EN   7 Download from Www.Somanuals.com. All Manuals Search And Download.   Dimensional   Data   Model EWFB   Type ASHDB-8 thru 20 Wall Mounted   Knockouts and Mounting Holes   Typical Installation   *Architectural Pedestal Heaters –   Series ASHDB-8 8” High   100-500 Watts Per Foot   *8" high ASHDB unit is the only size that can be mounted on pedestals.   8 FIN-PRC003-EN   Download from Www.Somanuals.com. All Manuals Search And Download.   Wiring   Diagrams   Model EWFB   Field Wiring With Integral Controls   When heaters are furnished with   controls, make certain that the heater or   heaters do not exceed the lowest   amperage rating of the controls   furnished. For example, if a thermostat   and disconnect are furnished, the   thermostat is rated at 25 amps 240 and   277, the disconnect is rated 20 amps 240   and 277. Therefore, the combination of   heaters should not exceed 20 amps at   277 or 240.   Controls   Description — Single Pole   Catalog Number – DBF-ITS, DBT-ITS,   CDF-ITS, CDT-ITS   Rated 25 amps at 120-277 VAC. 50-110°F   temperature range. Tamperproof and   adjustable through discharge louver.   Integral thermostats: wire entry from   • either end.   Disconnect switch: right hand wire   • • • • entry.   Thermostat and disconnect: right hand   wire entry.   Relays: right hand wire entry – control   section.   Description – Double Pole Thermostat   Catalog Number – DBF-ITD, DBT-ITD,   CDF-ITD, CDT-ITD   Thermostat – disconnect and relay:   right hand wire entry – control section.   Rated 25 amps at 120-277 VAC. 50-110°F   temperature range. Tamperproof and   adjustable through discharge louver.   Description – Disconnect Switch   Catalog Number – DBF-IDS, DBT-IDS,   CDF-IDS, CDT-IDS   Double pole rated 20 amps at 120-277   VAC.   Wiring Diagrams   Wiring Diagrams – Control Section   FIN-PRC003-EN   9 Download from Www.Somanuals.com. All Manuals Search And Download.   Wiring   Diagrams   Model EWFB   Field Wiring With Integral Controls   When heaters are furnished with   controls, make certain that the heater or   heaters do not exceed the lowest   amperage rating of the controls   furnished. For example, if a thermostat   and disconnect are furnished, the   thermostat is rated at 25 amps 240 and   277, the disconnect is rated 20 amps 240   and 277 VAC. Therefore, the combination   of heaters should not exceed 20 amps at   277 or 240 VAC.   Controls   Description – Single Pole   Catalog Number – CB-ITS   Rated 25 amps at 120-277 VAC. 50-110°F   temperature range. Tamperproof and   adjustable through discharge louver.   Integral thermostats: wire entry from   • either end.   Disconnect switch: mount either end.   • Thermostat and disconnect: mount   • either end.   Relays: control section.   Thermostat – disconnect and relay:   control section   • • Description – Double Pole Thermostat   Catalog Number – CB-ITD   Rated 25 amps at 120-277 VAC. 50-110°F   temperature range. Tamperproof and   adjustable through discharge louver.   Note: Control section is attached on   either side.   Description – Disconnect Switch   Catalog Number – CB-IDS   Double pole rated 20 amps at 120-277   VAC.   Wiring Diagrams   Wiring Diagrams – Control Section   10   FIN-PRC003-EN   Download from Www.Somanuals.com. All Manuals Search And Download.   Wiring   Diagrams   Model EWFB   When heaters are furnished with   controls, make certain that the heater or   heaters do not exceed the lowest   amperage rating of the controls   furnished. For example, if a thermostat   and disconnect are furnished, the   thermostat is rated at 25 amps 240 and   277, the disconnect is rated 20 amps 240   and 277. Therefore, the combination of   heaters should not exceed 20 amps at   277 or 240.   Field Wiring With Integral Controls   Controls   Description – Single Pole   Catalog Number – DBCF-ITS, DBCT-ITS   Rated 25 amps at 120-277 VAC. 50-110°F   temperature range. Tamperproof and   adjustable through discharge louver.   Integral thermostats: wire entry from   • either end.   Disconnect switch: right hand wire   • • • • entry.   Thermostat and disconnect: right hand   wire entry.   Description – Double Pole Thermostat   Catalog Number – DBCF-ITD, DBCT-ITD   Rated 25 amps at 120-277 VAC. 50-110°F   temperature range. Tamperproof and   adjustable through discharge louver.   Relays: right hand wire entry – control   section.   Thermostat – disconnect and relay:   right hand wire entry – control section.   Description – Disconnect Switch   Catalog Number – DBCF-IDS, DBCT-IDS   Double pole rated 20 amps at 120-277   VAC.   Wiring Diagrams   Wiring Diagrams – Control Section   FIN-PRC003-EN   11   Download from Www.Somanuals.com. All Manuals Search And Download.   Wiring   Diagrams   Model EWFB   When heaters are furnished with   controls, make certain that the heater or   heaters do not exceed the lowest   amperage rating of the controls   furnished. For example, if a thermostat   and disconnect are furnished, the   thermostat is rated at 25 amps 240 and   277 VAC, the disconnect is rated   Field Wiring With Integral Controls   Controls   Description – Single Pole   Catalog Number – RDBT-ITS   Rated 25 amps at 120-277 VAC. 50-110°F   temperature range. Tamperproof and   adjustable through discharge louver.   Integral thermostats: wire entry from   • either end.   Disconnect switch: right hand wire   • • • • entry.   Thermostat and disconnect: right hand   wire entry.   Relays: right hand wire entry – control   Description – Double Pole Thermostat   Catalog Number – RDBT-ITD   Rated 25 amps at 120-277 VAC. 50-110°F   temperature range. Tamperproof and   adjustable through discharge louver.   20 amps 240 and 277 VAC. Therefore, the   combination of heaters should not   exceed 20 amps at 277 or 240 VAC.   section.   Thermostat – disconnect and relay:   right hand wire entry – control section.   Description – Disconnect Switch   Catalog Number – RDBT-IDS   Double pole rated 20 amps at 120-277   VAC.   Wiring Diagrams   Wiring Diagrams – Control Section   12   FIN-PRC003-EN   Download from Www.Somanuals.com. All Manuals Search And Download.   Wiring   Diagrams   Model EWFB   Catalog Number ASHDB   Heaters Over 5' (1.52 M) Long May Have Two Heating Elements   Wiring Diagram – Heater Only   Wiring Diagrams   Wiring Diagrams – Control Section   FIN-PRC003-EN   13   Download from Www.Somanuals.com. All Manuals Search And Download.   Mechanical   Specifications Model EWFB   Heater Design: Units are of modern   square design, constructed of specified   materials and contain totally enclosed   junction boxes at both ends, aluminum   fin tube element(s), thermal overload   and a 1/2" (13 mm) EMT prewired   40 ampere wireway. Heater lengths   furnished in 2 foot (0.6 M) through   10 foot (3.0 M) in 1 foot (0.3 M)   lengths to 15 feet (4.6 M). Front panel   snap fit to the back panel with out   fasteners for two-piece construction.   Back panel is pre-punched for easy   installation and is suitable for mullion to   mullion installation for wall mounted   heaters only.   Specifications   Natural convection heavy-duty electric   wall fin are furnished to meet the   specified wattage, voltage and size. Units   installed and wired in accordance with   the manufacturer’s recommendations   and applicable national and local codes.   Extended Enclosures: Are manufactured   with solid metal grilles and extends the   enclosure length another 6" (152 mm),   12" (305 mm), 18" (457 mm), 24" (610   mm), 30" (762 mm), 36" (914 mm), 42"   (1067 mm), 48" (1219 mm), 54" (1372   mm) and 60" (1524 mm). Heater and   Extended Enclosure are furnished as a   one piece unit. Used to factory mount 6"   (152 mm) and 12" (305 mm) Control   Sections. Left or right hand mounting of   the Control Section must be specified.   Maximum Length with Extended   Mounting: Electric wall fin heaters   designed to be securely attached to the   wall (or optional floor mounted on   pedestals) per manufacturer’s   instructions. Heaters are wired for either   right or left hand entry where there are   no controls, otherwise entry will be in   the junction box containing controls.   increments.1/2" (13 mm) and 3/4   " (19 mm) knockouts are provided on the   side and rear of the heaters junction box   to allow end to end wiring for wall   mounted units and in the bottom of the   junction box only for floor mounted   heaters.   Heaters with bottom air intake and top   air exit and front air intake (inlet grille)   and top air exit (both wall and pedestal   styles) must be mounted a minimum of   3" (76 mm) off the finished floor.   Enclosure front panel are of one piece   construction suitable for architectural,   commercial and industrial use, with   1 /4" (6.4 mm) pencil-proof top air   discharge and or front air intake louvers.   Louvers discharge heated air at a 15   degree angle for cleaner operation. The   one-piece front panel is extruded for   maximum strength and is available in   Enclosures are 15 feet (4.6 M) for heater   models DBT, DBF and CB, 12 feet (3.7 M)   for heater models DBCT, DBCF and   RDBT-PD and 10 feet (3.04 M) for heater   model ASHDB.   Heaters with front air intake (inlet grille)   and top air exit can be wall mounted at   the finished floor level and are approved   for zero clearance at the bottom.   14   FIN-PRC003-EN   Download from Www.Somanuals.com. All Manuals Search And Download.   Mechanical   Specifications Model EWFB   Model RDBT-PD – Pedestal mounted   Enclosure Models and Type:   Model CB – Wall mounted (bottom air   • • (bottom air intake and top air outlet)   enclosure are rounded with a flat top   air discharge, 5" (127 mm) high x   6" (152 mm) deep manufactured from   12-gauge (2.7 mm) thick extruded   aluminum. Extrusion is .100" (2.5 mm)   thick heat treated to T-5 hardness.   Pedestals are 2" (51 mm) high for   overall height of 7" (178 mm) from the   floor to the top of the enclosure.   Maximum wattage is 300 watts per   foot (984 watts per meter).   inlet and top air outlet) are snap fit   two-piece construction, 4 1/2" (114 mm)   high x 2 5/8" (67 mm) deep   Model DBT – Wall mounted (bottom air   • inlet and top air outlet) are snap fit two-   piece construction, 6" (152 mm) high x   3 1/2" (89 mm) deep manufactured from   12-gauge (2.7 mm thickness) extruded   aluminum. Extrusion are .100" (2.5   mm) thick 6063 aluminum heat treated   to T-5 hardness. Backplates are 12-   gauge (2.7 mm thickness) extruded   aluminum. Maximum wattage is 300   watts per foot (984 watts per meter).   manufactured from 14-gauge (1.9 mm   thickness) extruded aluminum.   Extrusion is .70" (1.8 mm) thick 6063   aluminum heat treated to T-5 hardness.   Backplates are 14-gauge (1.9 mm   thickness) extruded aluminum.   Maximum wattage is 250 watts per   foot (820 watts per meter).   Model DBCT – Wall mounted (bottom   air inlet and top air outlet) are snap fit   two-piece construction, 7" (178 mm)   high x 5" (127 mm) deep manufactured   from 10-gauge (3.4 mm thickness)   extruded aluminum. Extrusion is .100"   (2.5 mm) thick 6063 aluminum heat   treated to T-5 hardness. Backplates are   10-gauge (3.4 mm thickness) extruded   aluminum. Maximum wattage is 750   watts per foot (2460 watts per meter).   • • Model DBF – Wall mounted (bottom   • Model ASHDB – Wall mounted   • front air inlet grille and top air outlet) is   snap fit two-piece construction,   6" (152 mm) high x 3 1/2" (89 mm) deep   manufactured from 12-gauge (2.7 mm   thickness) extruded aluminum.   Extrusion is .100" (2.5 mm) thick 6063   aluminum heat treated to T-5 hardness.   Backplates are 12-gauge (2.7 mm   thickness) extruded aluminum for zero   clearance mounting. Maximum   wattage is 250 watts per foot (820   watts per meter).   (bottom air inlet and top air outlet) are   available in 8" (203 mm), 10" (254 mm),   12" (305 mm), 14" (356 mm), 16" (406   mm) 18" (457 mm) and 20" (508 mm)   heights in a 5 1/2" (140 mm) depth.   Enclosure front and back panel are   manufactured from 16-gauge (1.5 mm   thickness) steel and is snap fit two-   piece construction. Discharge grille is   12-gauge (2.7 mm thickness) one piece   continuous extruded aluminum,   .100" (2.5 mm) thick 6063 aluminum   heat treated to T-5 hardness.   Model DBCF – Wall mounted (front air   inlet grille and top air outlet) are snap   fit two-piece construction, 7" (178 mm)   high x 5" (127 mm) deep manufactured   from 10-gauge (3.4 mm thickness)   extruded aluminum. Extrusion is .100"   (2.5 mm) thick 6063 aluminum heat   treated to T-5 hardness. Backplates are   10-gauge (3.4 mm thickness) extruded   aluminum. Maximum wattage is 650   watts per foot (2133 watts per meter).   Maximum wattage is 500 watts per   foot (1640 watts per meter).   FIN-PRC003-EN   15   Download from Www.Somanuals.com. All Manuals Search And Download.   Mechanical   Specifications Model EWFB   Control Options: Built-in thermostat and   Heating Elements: Element(s) consist of   high quality nickel chromium alloy   resistance wire embedded and   completely surrounded by magnesium   oxide, enclosed and swaged in an   aluminum sheath. Aluminum fins are   mechanically bonded to the sheath for   efficient heat transfer. The element   fin temperature will not exceed   330°F (166°C) to help assure long   element life. The heating element is   center anchored and free floating at each   end on nylon bushings for quiet   operation.   ATR – Transformer relay single pole,   • disconnect are rated for 20 amps, 120-   rated 25 amp 120-277 VAC contacts   277 VAC. Transformer relay are rated 25   rated up thru 277 volt and must be   amp, 120-277 VAC and power relays   specified. Coils are 24 volt and 120 volt   rated for 18 amps. They are factory   and must be specified.   installed with one device per junction   PR 208/24, 18 amp power relay   contactor.   • box or a 6" (152 mm) long or 12" (305   mm) long control section can be used   PR 240/24, 18 amp power relay   contactor.   due to the heaters size or more than two   controls are required per heater.   • • • PR 277/24, 18 amp power relay   contactor.   ITS – Single pole thermostat, 20 amp,   • is adjustable thru discharge grille   factory mounted and wired in left hand   junction box.   ATR – Transformer relays and all   PR-power relays require a control   section and a 12" (305 mm) long   extended enclosure for installation.   Thermal Overload: A full length tubular   automatic reset thermal overload   disconnects the heating element(s) in the   event normal operating temperatures   are exceeded.   ITD – Double pole thermostat, 20 amp,   • is adjustable thru discharge grille   factory mounted and wired in left hand   junction box.   IDS – Double pole disconnect switch,   • Volts/Phase: All models available in the   following volts and phase 208/1, 240/1,   277/1 or 120/1.   20 amp, is adjustable thru discharge   grille factory mounted and wired in   right hand junction box.   Watts/Foot   Watts Per Foot   (Single Element Heaters)   93, 125, 141, 188, 250 & 282   Watts Per Foot   (Double Element Heaters)   282   Models   DBT &   RDBT   DBF &   CB   93, 125, 141, 188 & 250   None   DBCF &   ASHDB   DBCT   93, 125, 141, 188, 250, 282,   333 & 375   93, 125, 141, 188, 250, 282,   282, 376, 438 & 500   282, 376, 438, 500, 564, 625,   666 & 750   333 & 375   16   FIN-PRC003-EN   Download from Www.Somanuals.com. All Manuals Search And Download.   Mechanical   Specifications Model EWFB   Control Sections:   Pedestals – Pedestal brackets are   available for floor mounting in lobbies   and in front of windows for all models   except ASHDB 10" (254 mm), 12" (305   mm), 14" (356 mm), 18" (457 mm) and   20" (508 mm) high heaters. Factory   installed to the bottom of the unit for   field furnished power wiring to be run   through the center of the pedestal into   the bottom of the units junction box for   connection to the heater.   Color Finish Options   • • - Clear Anodized   6" (152 mm) long control section for   • - Bronze Anodized   - Black Anodized   - Beige Baked Enamel* 2-7-2894   - White Baked Enamel* 2-1-5098   - Brown Baked Enamel* 2-7-3894   - Black Baked Enamel* 2-6-5054   factory mounting of 1 or 2 controls.   Right or left side mounting are   available with right side being   standard. Requires one foot (0.3048 M)   of extended enclosure for installation.   Control sections are field wired to the   heater.   *Colors per Electric Wall Fin Color   Selection Chart FIN-S-3.   12" (305 mm) long control section for   • factory mounting of 1, 2 or 3 controls.   Right or left side mounting are   available with right side being   standard. Requires one foot (0.3048 M)   of extended enclosure for installation.   Control sections are field wired to the   heater.   Anodized colors available for all   models except Model ASHDB.   • The knockouts that are provided in the   side and rear of each heaters junction   box and the back panel mounting   holes for wall mounting of units are   not furnished when pedestals are   ordered.   Hydronic Heating Units   Blank enclosure sections for use with   hydronic heating elements are modified   to have the air outlet grille and bottom   air inlet or bottom front air inlet grille in   the same configuration as listed above   for each model electric heater.   2' to 6' (0.6 to 1.83 M) heaters require   two pedestals, 6' to 8' (1.83 to 2.44 M)   heaters require three pedestals,   9' (2.74 M) and 10' (3.05 M) heaters   require four pedestals.   Accessories: Accessories are approved   as 40 ampere wireways and are of the   same material and compatible design   as the heater section.   Maximum Element Fin Size per Model   Model Maximum Fin Size   DBT & 23/4" x 4"   and 31/4" x 31/4   " Inside corners 90 - 180 degrees.   • Finished Back Panels – Finished back   panels either painted or anodized in   the same color as the heater are   available for pedestal floor mounted   heaters to be installed in front of   windows and in lobbies.   • • DBCT   70 mm x 102 mm   and 83 mm x 83 mm   Outside corners 180 - 270 degrees.   DBF & 23/4" x 4"   and 23/4" x 3"   and 70 mm x 76 mm   • DBCF   70 mm x 102 mm   End caps left or right hand.   • ASHDB 41/4" x 41/4   " 2" (51 mm) and 6" (152 mm) wall trims.   1 1/2" (38 mm) splice plates.   108 mm x 108 mm   • Note:   31/4" (83 mm) x 51/4" (133 mm) fin size and   23/4" (70 mm) x 5" (127 mm) fin size cannot be used with   these size enclosures.   • 1 / 4" (6.4 mm) wire mesh factory   Blank enclosure sections manufactured   of solid metal grilles and are   • installed under outlet grille on   enclosure and blank enclosure sections   and extended enclosure sections.   independent pieces of enclosure not   joined to the heater and are fully   enclosed to allow branch circuit wiring.   Available in 1 foot (0.3048 M) through   10 foot (3.048 M) lengths in 1 foot   (0.3048 M) increments. Can be   modified for use with hydronic heating   elements for models DBT, DBF, DBCT,   DBCF and ASHDB only.   FIN-PRC003-EN   17   Download from Www.Somanuals.com. All Manuals Search And Download.   Download from Www.Somanuals.com. All Manuals Search And Download.   Download from Www.Somanuals.com. All Manuals Search And Download.   FIN-PRC003-EN   Literature Order Number   File Number   PL-TD-FIN-000-PRC003-EN-1001   FIN-DS-5 0798   Supersedes   The Trane Company   An American Standard Company   La Crosse   Stocking Location   For more information contact   your local sales office or   e-mail us at [email protected]   Since The Trane Company has a policy of continuous product and product data improvement, it reserves the   right to change design and specifications without notice.   Download from Www.Somanuals.com. All Manuals Search And Download.   |