Sylvania Table Top Game F075615 User Manual

Safety  
SHOCK HAZARD!  
Only qualified individuals should install this heater and related controls.  
Follow all applicable electrical codes and use proper wiring.  
BURN HAZARD!  
Avoid contact with the heater nozzle during or soon after operation.  
EXPLOSION HAZARD!  
Heater produces extremely high temperatures. Do not use in  
hazardous environments, and/or near explosive or reactive gases,  
or combustible materials.  
OSRAM SYLVANIA  
131 Portsmouth Avenue  
Exeter, NH 03833 USA  
+
800-258-8290  
+
603-772-4331  
,: 603-772-1072  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
06/01/2008  
Heater Models and Parts List  
SKORPION™ AIR HEATERS  
REPLACEMENT PARTS  
1” NPT  
adaptor  
plate  
Heating  
Element  
Temp  
Control  
SSR Power  
Blower  
Nozzle  
Tube  
Control  
Complete Unit with Blower  
F205526  
F205502  
F205614  
F205499  
F205499  
F205499  
F205486  
F205486  
F205486  
F205513  
F205512  
F205604  
N/A  
N/A  
N/A  
F205494  
F205494  
F205494  
F075615 1.5kW 120V~ 1 Ø 12.5A  
F075616 3.0kW 230V~ 1 Ø  
F076008 4.5kW 230V~ 1 Ø  
13A  
20A  
Complete Unit without Blower*  
F205526  
F205526  
F205614  
F205499  
F205499  
F205499  
F205486  
F205486  
F205486  
N/A  
N/A  
N/A  
F205549  
F205549  
F205549  
F205494  
F205494  
F205494  
F075869 1.5kW 120V~ 1 Ø 12.5A  
F075835 3.0kW 230V~ 1 Ø 13A  
F076029 4.5kW 230V ~ 1 Ø 20A  
*SKORPION Models without Blower are supplied with a 1” NPT adaptor plate for separate  
air source connection (<5 PSI).  
ACCESSORIES  
F075744  
F075745  
F075746  
High Flow Nozzle  
Standard Flare  
Wide Flare  
21mm (1”) diameter  
150mm x 12mm (6”x0.5”)  
300mm x 4mm (12”x 0.16”)  
OSRAM SYLVANIA  
131 Portsmouth Avenue  
Exeter, NH 03833 USA  
+
+
800-258-8290  
603-772-4331  
,: 603-772-1072  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
06/01/2008  
General Information  
Environmental Conditions  
Ambient Temperature  
Humidity  
0°C to 38°C (32°F to 100°F)  
0% to 90% R.H.  
Ambient Pressure  
0.8 to 1.2 Bar (11.8 psia to 17.6 psia)  
Ventilation  
Use in a well-ventilated area away from excess dust, dirt, and moisture.  
Cleaning  
With unit OFF and unplugged, exterior surfaces  
may be wiped clean using a damp cloth.  
Attaching 230V (European style) plugs  
(see diagram):  
NOTE: Use plug appropriate for local area and codes.  
Only qualified personnel should perform wiring.  
Overcurrent protection should be provided external  
to the heater unit within plug type shown or similar fusing.  
Protective Earthing  
The yellow and green ground wire in the power cable is attached directly to the aluminum  
base plate inside the heater via a dedicated screw terminal. Additional protective earthing  
can be attached to the aluminum base plate if desired.  
Basic Operation  
1. Turn SKORPION air heater ON using two switches:  
1.1. Switch S1 (blower) sends power to the blower and to heater switch S2.  
1.2. Switch S2 (heater) sends power to the heater control circuit.  
1.3. Note, for heater safety, S2 (heater) cannot turn ON without S1 (blower) ON.  
2. Adjust airflow via a rotational air damper at the blower inlet.  
3. Adjust temperature set point with the UP/DOWN arrows on the temperature controller.  
Heater will ramp to temperature.  
3.1. The process temperature is measured with an internal type “K” thermocouple located at  
the end of an element inside the stainless housing.  
4. When turning the heater off the heater power (S2) may be turned off and the blower (S1)  
left on to cool the heater housing assembly. This is suggested to prevent burn injury of  
personnel around the heater but is not necessary for safety of the heater element.  
OSRAM SYLVANIA  
131 Portsmouth Avenue  
Exeter, NH 03833 USA  
+
+
800-258-8290  
603-772-4331  
,: 603-772-1072  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
06/01/2008  
Detailed Operation  
Heater Voltage is regulated by a Solid State Relay (SSR), which is turned ON and OFF  
rapidly according to the temperature controller DC OUT signal. A “zero cross” type SSR  
is used to minimize electrical noise.  
Heater Element is protected with a resistive photo detector and a thermal resistor  
(thermistor) mounted at the heater inlet. These sensors are connected in parallel with the  
DC input signal going to the SSR.  
o
o
o
If the element overheats (bright orange color) the photo detector resistance  
decreases which reduces the control signal which, in turn, limits power to the  
heater.  
If the air temperature in the housing reaches an unsafe level, the thermistor  
resistance decreases which reduces the control signal, which in turn, limits power  
to the heater.  
A small fixed resistor in series with the control signal sets element and air  
temperature limits.  
The large black dots on the wiring diagram represent connections that are made on the  
internal terminal strip. The terminal strip allows the customer easy access to remove and  
replace the heater element and blower if necessary.  
OSRAM SYLVANIA  
131 Portsmouth Avenue  
Exeter, NH 03833 USA  
+
+
800-258-8290  
603-772-4331  
,: 603-772-1072  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
06/01/2008  
Performance  
Without  
blower*  
Heater Model  
1.5kW 120V  
3.0kW 230V  
4.5kW 230V  
MAXIMUM AIR TEMP  
with exit restriction  
1000°F  
(540°C)  
1400°F  
(760°C)  
1400°F  
(760°C)  
Open ended/flare  
High flow nozzle  
*see note  
*see note  
1300°F  
(730°C)  
1400°F  
(760°C)  
1400°F  
(760°C)  
MAXIMUM FLOW RATE  
no restriction, 60Hz power.  
25 SCFM  
(708 SLPM)  
25 SCFM  
(708 SLPM)  
45 SCFM  
(1274 SLPM)  
At 20°C (68°F)  
*see note  
*see note  
12 SCFM  
(340 SLPM)  
12 SCFM  
(340 SLPM)  
22 SCFM  
(623 SLPM)  
At 750°C (1400°F)  
* FOR SKORPION models without Blower (external air source):  
A) The maximum temperature capability of heater will depend entirely on the airflow rate  
produced by external air source. Higher airflow rates than those produced by the standard  
SKORPION blower will yield lower maximum temperatures.  
B) External air supply must be turned ON prior to turning heater ON  
C) For best flow conditions, use min. ” NPT size incoming air line.  
D) Do not exceed 5 psi (.34 BAR) or air leaks will be noticeable in the heater.  
OSRAM SYLVANIA  
131 Portsmouth Avenue  
Exeter, NH 03833 USA  
+
+
800-258-8290  
603-772-4331  
,: 603-772-1072  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
06/01/2008  
Replacement Procedures  
I. Replacing the Heating Element  
1. Turn heater/blower switches OFF, and disconnect from power source.  
2. Use a flat screwdriver to remove (pry open) the wiring cover under the stainless nozzle  
tube.  
3. Remove the stainless nozzle by removing the two mounting screws, and the thru-bolt  
which passes through the plastic support tower and threads into the nozzle flange.  
4. Disconnect the KTC+ (Yellow), KTC- (Red), HTR1, HTR2 connections from the wiring  
terminal as shown. Total of four wires.  
5. Remove the old element, pulling the KTC and HTR wires through the plastic support  
tower.  
6. Install new element by reversing steps 2-5.  
II. Replacing the Temperature Controller  
1. Turn heater/blower switches OFF, and disconnect from power source.  
2. Remove the four screws which secure the black plastic top cover plate.  
3. Remove the four screws which attach the aluminum base plate to the main heater plastic  
structure.  
4. With the top cover plate and the aluminum plate removed, you now have access to the  
top and bottom mounting tabs on the temperature controller.  
5. While lifting the top and bottom white plastic mounting tabs, gently push the temperature  
controller halfway out of the faceplate.  
6. Using masking tape or other method, mark each wire going to the back of the controller  
with a number 1-9, corresponding to its terminal location. This is CRITICAL to ensure  
proper wiring to the new controller.  
7. Using a small screwdriver, loosen and remove the wires from the terminals at the rear of  
the temperature controller.  
8. Remove temperature controller completely from the faceplate.  
9. Install new temperature controller halfway into faceplate.  
10. Reconnect the wires according to the terminal number and ID marking from step #4.  
11. Press controller into faceplate while engaging the white mounting tab securely.  
12. Replace the black plastic top cover plate and reattach mounting screws.  
OSRAM SYLVANIA  
131 Portsmouth Avenue  
Exeter, NH 03833 USA  
+
+
800-258-8290  
603-772-4331  
,: 603-772-1072  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
06/01/2008  
III. Replacing the Power Controller  
NOTE: Thermally conductive compound (“heat sink grease”) is required to mount new SSR.  
1. Turn heater/blower switches OFF, and disconnect from power source.  
2. Remove the four screws which secure the black plastic top cover plate.  
3. Remove the four wires connecting to the four terminals on the solid state relay. Be sure  
to mark the wires clearly for re-installation.  
4. Remove the two screws holding the Solid State Relay from the aluminum base plate and  
remove the SSR.  
5. Carefully wipe off the old white heat sink putty from the base plate and apply new heat  
sink putty on the back of the new SSR.  
6. Mount SSR onto aluminum base plate with the mounting screws and reconnect wires.  
7. Replace the black plastic top cover plate and reattach mounting screws.  
IV. Replacing the Blower  
1. Turn heater/blower switches OFF, and disconnect from power source.  
2. Use a flat screwdriver to remove (pry open) the wiring cover under the stainless nozzle  
tube.  
3. Remove the blower by removing the three mounting bolts. One of these bolts passes  
through the plastic support tower and threads into the nozzle flange.  
4. Disconnect the GND, FAN1, and FAN2 connections from the wiring terminal as shown.  
Total of three wires.  
5. Remove the blower, GND, FAN1, FAN2 wires through the plastic support tower.  
6. Install new blower by reversing steps 2-5.  
OSRAM SYLVANIA  
131 Portsmouth Avenue  
Exeter, NH 03833 USA  
+
+
800-258-8290  
603-772-4331  
,: 603-772-1072  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
06/01/2008  
SKORPION™ (1.5kW/3.0kW)  
OSRAM SYLVANIA  
131 Portsmouth Avenue  
Exeter, NH 03833 USA  
+
+
800-258-8290  
603-772-4331  
,: 603-772-1072  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
06/01/2008  
SKORPION™ (4.5kW)  
OSRAM SYLVANIA  
131 Portsmouth Avenue  
Exeter, NH 03833 USA  
+
+
800-258-8290  
603-772-4331  
,: 603-772-1072  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
06/01/2008  
SKORPION™ Without Blower (1.5kW/3.0kW/4.5kW)  
OSRAM SYLVANIA  
131 Portsmouth Avenue  
Exeter, NH 03833 USA  
+
+
800-258-8290  
603-772-4331  
,: 603-772-1072  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
06/01/2008  
OSRAM SYLVANIA  
131 Portsmouth Avenue  
Exeter, NH 03833 USA  
+
800-258-8290  
+
603-772-4331  
,: 603-772-1072  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sennheiser Marine Radio SK 3063 U User Manual
Sony Car Stereo System XR C7500R User Manual
Sony TV Cables HXCU D70 User Manual
Sony Wireless Office Headset MDRAS600BT B User Manual
SOYO Computer Hardware mother board fc pga socket 370 pocessor supported User Manual
Speco Technologies Portable Speaker SP 5AWD T User Manual
Star Manufacturing Cooktop 502D User Manual
Sunbeam Coffeemaker SPR 101006 User Manual
Sylvania CRT Television TVK139V User Manual
TANDBERG Computer Monitor 770 MXP User Manual