I m p o r t a n t S a f e g u a r d s  
3
IMPORTANT SAFEGUARDS  
Do not operate this equipment without first reading and understanding this manual.  
Should you be unable to understand the warnings, cautions and instructions,  
contact our technical support or your local dealer before attempting to use this  
equipment– otherwise injury or damage may result.  
Important information is highlighted by these terms:  
WARNING– Notices as used in the manual apply to hazards or unsafe practices which  
could result in serious bodily harm.  
CAUTION–  
Notices as used in this manual apply to hazards or unsafe practices, which  
could result in minor personal injury or property damage.  
NOTES–  
Highlight procedures and contain information which assist the operator in  
understanding the information contained in this manual.  
NOTE– The information contained in this document is subject to change without notice.  
SAVE THESE INSTRUCTIONS AND KEEP WITH EASYTRACK AT ALL TIMES.  
The Easytrack System and its accessories are intended to be used as an assistive  
device for transferring a person between the posts. The Easytrack system is only  
to be used with the Guardian Voyager Portable lift.  
USE ONLY AS INTENDED - This product may cause serious injury if not installed and  
operated according to the instruction manual.  
Failure to observe warnings listed below could result in serious injury.  
This instruction manual is for the installation of the Easytrack Wall Mount only. For more  
information about the Easytrack system, please refer to the Easytrack user manual.  
Before you Install the Easytrack Wall Mount  
If you are unsure of the strength or stability of your wall, do not install the wall  
mount; consult you local supplier.  
Do not install on a wall with water damage.  
Do not drop product; may cause breakage.  
Do not completely submerge in water.  
Do not attempt to over-extend the rail past the locking point.  
When the Easytrack is in Use  
Do not use the Easytrack system as a swing.  
Refrain from swinging patient sideways of rail.  
Wall Mount Assembly  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
A s s e m b l y I n s t r u c t i o n s  
1
ASSEMBLY INSTRUCTIONS  
36-40"  
(915-1020mm)  
REQUIREMENTS  
16-18"  
(400-460mm)  
Failure to meet requirements listed below could result in serious bodily harm.  
Wall mount should be installed by a skilled tradesperson. Installation of the wall  
mount by someone unskilled will void Sunrise warranty and may cause serious injury  
or damage.  
Every month a maintenance check should be done to ensure the rail is level (see  
“Maintenance” in this manual).  
Protect the Easytrack System and its accessories during transport.  
Wall Requirements:  
WOOD STRUCTURE – minimum 2” X 3” Studs  
2
3
CONCRETE STRUCTURE  
Do no install if wall does not meet requirements.  
Do not install on a wall with a steel structure.  
BEFORE YOU BEGIN  
53"  
(1340mm)  
Read “Requirements” and “Important Safeguards” before attempting to assemble  
the Easytrack System.  
1. Survey the room where you plan to install the Easytrack Wall Mount. Make sure the  
room meets all the specifications outlined in “Requirements.  
2. Use the measurements below to determine the best place to put the Easytrack System:  
a. Over a bed – approx. 36-40” (915-1020 mm) from the head of the bed (Figure 1).  
b. Over a tub – approx. 16-18” (400-460 mm) from the end of the tub (Figure 1).  
c. Allow 36” (915 mm) of open area for transfer working space (Figure 2).  
d. Allow a minimum of 53” (1340 mm) from the bottom of the rail to the top of any  
object to be transferred over (Figure 3).  
4
20"  
(510mm)  
80.2-130"  
(2040-3300mm)  
84-108"  
(2130-2745mm)  
3. Transfers should only take place under the Easytrack rail (Figures 4 & 5).  
4. The Wall Mount may be installed on either a concrete wall or wood-framed wall. For  
wood, the wall mount must be attached to a minimum of three (3) 2" X 3" studs. DO  
NOT attempt to install the wall mount on less than 3 studs (Figure 6).  
5. Wall Mount must be positioned on the wall to ensure the angle between the wall and  
the rail will be more than 30° (Figure 7).  
5
6
7
84.8-134.5"  
(2155-3415mm)  
studs  
wall mount plate  
Maximum angle  
30°  
30°  
Wall Mount Assembly  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A s s e m b l y I n s t r u c t i o n s  
5
EASYTRACK WALL MOUNT KIT  
CONTENTS & PART NUMBERS (Figure 8)  
8
1
2
Description  
Part #  
Qty  
1
2
Wall mount plate  
Pivoting rail  
attachment  
900-1085  
1
3
900-1087  
1
Includes:  
4
3
4
5
6
7
Round blue cap  
900-1072  
N/A  
N/A  
N/A  
900-0409  
1
1
1
1
1
Pivot wall mount  
Fixation wall mount  
Back plate  
6
7
M 10 X025 screw  
5
ASSEMBLY OF WALL MOUNT ASSEMBLY  
Tools required:  
standard rail  
9a  
9b  
10  
11  
12  
Step ladder  
Tape measure  
1 1/8"  
(28mm)  
6 concrete 3/8” anchors or 6 3/8” lag bolts  
Drill  
Wrench with a 9/16” socket  
Someone to assist you  
Stud finder  
pivoting rail  
1. Refer to Figures 9A and 9B for the distance required between the ceiling and where  
the top of the wall mount must be installed. Please note that when the wall bracket  
will have the pivoting rail of a 3 post system attached, the mounting point must be  
lower than with a standard rail.  
2. Insert the pivoting rail attachment into the wall plate. Refer to Figure 10 to insure  
that the bracket is placed properly.  
3. Install the wall plate on the wall. The wall plate must be installed on a concrete wall  
with six (6) 3/8 in. concrete anchors or on three (3) 2x3 (minimum size) wooded studs  
with two (2) 3/8" diameter (M10), 4 in. long lag bolts on each stud (Figure 11).  
Wood studs– Use a stud finder to find the center of each stud. It is necessary to pre-  
drill holes into each stud before screwing the lag bolt to prevent the wood from  
cracking.  
5 1/4"  
(133mm)  
ceiling  
NOTE– Make sure the rail is level before securing wall mount to wall.  
bottom  
Follow drill size recommendation for lag bolt:  
LAG BOLT  
M10  
3/8 "  
PRE-DRILL SIZE 6.5 mm 1/4 "  
Pre-drilled holes must be in the center of the stud. If holes are not properly  
centered, serious damage or injury may occur.  
DO NOT install into steel stud, reinforcement may be required.  
Maximum angle  
CAUTION– Avoid drilling close to any electrical wiring or plumbing. Please, make sure you know what  
is behind the wall you are drilling in before doing any modifications to it. Failure to do so  
may cause serious injury.  
4. See “Before you start” for suggested position. Slide the pivoting rail attachment into its  
final position. For the 3 post assembly, the bracket must be placed in a way that the rail  
won’t, when turning, generate an angle beyond the maximum allowed (Figure 12).  
5. Tighten the four bolts on pivoting rail attachment. The rail can now be attached to  
wall mount.  
30°  
30°  
Wall Mount Assembly  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
M a i n t e n a n c e  
MAINTENANCE  
Failure to follow maintenance instructions below when indicated could result in  
injury or damage.  
Periodic inspection should be performed by a person who is suitably and properly qualified  
and well acquainted with the design, use and care of the Easytrack System. Contact your  
local dealer/distributor.  
Inspection should be carried out both routinely (at least as often as specified) and, as nec-  
essary. If any damage to the system is detected through routine inspections, do not use  
the system and immediately contact your supplier.  
Upon receipt of your Easytrack Wall Bracket:  
1. Make sure you received all components listed in Figure 8.  
2. Inspect all parts for possible damage in transit.  
3. Ensure all components are in working order.  
4. Repair/replacement of any faulty parts.  
5. Keep a log of any repair/replacement required.  
Before each time you use the Easytrack Wall Bracket:  
1. Clean the outside and inside of the rail and wipe out any water in the rail. Failure to  
do so for a long period of time can cause corrosion that will weaken the rail.  
2. Check that the rail is secure in place. Press the rail upwards to make sure that the  
rail is locked onto the post.  
3. Check if there is any appearance of damage. If there is any appearance of damage,  
do not use the Easytrack System.  
Every month:  
1. Clean inside of rail with a damp cloth to ensure there is no dust or grease build-up  
inside of rail.  
2. Check to ensure you still have all your original parts. If any parts are missing they  
should be replaced before using the Easytrack Wall Bracket again.  
3. Check for the appearance of rust. If rust is starting to appear, simply scrub the piece  
clean.  
4. Examine all joints and pieces for wear and fatigue. Replace any part that looks dam-  
aged or worn. Document inspection and any repairs.  
Follow guidelines in your portable lift manual for maintenance and procedures on  
the lift.  
Wall Mount Assembly  
Download from Www.Somanuals.com. All Manuals Search And Download.  
W a r r a n t y  
7
WARRANTY  
This warranty is extended only to the original purchaser/user of Sunrise products.  
Sunrise Medical Inc. warrants its products to be free from defects in material under normal  
use and service and will, within the periods stated below, from the date of purchase. If  
within such warranty period any such product shall be proven to be defective, such product  
shall be repaired or replaced at Sunrise Medical's option. This warranty does not include  
any labor or shipping charges incurred in replacement part installation or repair of any such  
product. Sunrise Medical's sole obligation and your exclusive remedy under this warranty  
shall be limited to such repair and/or replacement.  
Lifter including hydraulics  
Accessories on Lifter  
Slings  
1 year  
1 year  
1 year  
Batteries  
3 months  
1 year  
Easytrack System  
For warranty service, please contact the provider from whom you purchased the Sunrise  
Medical product. In the event that you do not receive satisfactory warranty service, please  
contact Sunrise Medical customer service at 1-800-333-4000.  
Do not return products to our factory without prior authorization. Sunrise Medical will issue  
a Return Merchandise Authorization (RMA) Number. C.O.D. shipments will be refused; all  
shipments to Sunrise Medical must be prepaid. For this warranty to be valid, the purchaser  
must present its original proof of purchase at the moment of the claim. The defective unit,  
assembly or part must be returned to Sunrise Medical for inspection. The part or compo-  
nents repaired or replaced are guaranteed for the remaining period of the initial warranty.  
Limitations and Exclusions:  
The above warranty does not apply to serial numbered products if the serial number has  
been removed or defaced.  
No warranty claim shall apply where the product or any other part thereof has been altered,  
varied, modified, or damaged; either accidentally or through improper or negligent use and  
storage. Warranty does not apply to products modified without Sunrise Medical's express  
written consent, (including but not limited to products modified with unauthorized parts or  
attachments); products damaged by reason of repairs made to any component without the  
specific consent of Sunrise Medical, or to products damaged by circumstances beyond  
Sunrise Medical's control. Evaluation of warranty claim will be solely determined by Sunrise  
Medical. The warranty does not apply to problems arising from normal wear or failure to  
adhere to the instructions in this manual. Sunrise Medical Inc. slings are void of warranty  
if not laundered as per instructions on the Sling Label.  
Sunrise Medical Inc. shall not be liable for damages losses or inconveniences caused by a  
carrier.  
This warranty replaces any other warranty expressed or implicit and constitutes Sunrise  
Medical Inc.'s only obligation towards the purchaser. Sunrise Medical shall not be liable for  
any consequential or incidental damages whatsoever.  
Wall Mount Assembly  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Manufactured for:  
Sunrise Medical  
7477 East Dry Creek Parkway  
Longmont, Colorado 80503  
(800) 333-4000  
In Canada (800) 263-3390  
Printed in Canada  
© 2002 Sunrise Medical 5.02  
900-0690 Rev. A  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Server Technology Switch CDUCW 16V MX User Manual
Sharp Cash Register ER A440S User Manual
Sharp Flat Panel Television LC 26D7U User Manual
Sony Camera Accessories BRS 200 User Manual
Sony Cassette Player XR CA630X User Manual
Sony Computer Monitor CPD L181 User Manual
Sony Laptop C1VPK User Manual
Sony Speaker SRS D511 User Manual
Spalding Fitness Equipment M8660411 User Manual
Swisher Log Splitter LS12534D LS622 LS57525 LS928 LS11534 User Manual