State Industries Water Heater Commercial Electric Water Heater User Manual |
C O M M E R C I A L
™
PATRIOT
LIGHT-DUTY
COMMERCIAL ELECTRIC WATER HEATERS
Designed for use as recovery heaters for
light-duty hot water supply service.
Patriot PCE water heaters are available
with tank capacities from 6 through 119
gallons. They can be installed for non-
simultaneous and single element operation
(maximum input up to 6 KW), or for
simultaneous dual-element operation
(maximum input up to 12 KW).
• Manual reset high temperature cutoff
per element (dual-element models)
™
• Factory wired for non-simultaneous
operation; easily converted to simulta-
neous operation
Glass-Lined Tank with
Anode Rod
• Provides long-lasting protection against
corrosion
Zinc-Plated Copper Sheath
Heating Elements Standard
Maximum Hydrostatic Working
Pressure: 150 psi
• Medium watt density design disperses
element temperature over larger
surface contact area to minimize scale
buildup, maximize efficiency and pro-
long element life
Meets or exceeds the thermal
efficiency and/or standby loss
requirements of the U.S.
Department of Energy and current
edition of ASHRAE/IESNA 90.1
• Element options from 1.5 KW to 6
KW (non-simultaneous or simultane-
ous operation), recoveries from 6 gph
to 49 gph at 100°F rise
Other Patriot™ PCE
Series Features
Standard Voltages for
Easy Installation
• Simplified, color-coded circuitry for
ease of service
• 120V, 277V single-phase, and 208V,
240V and 480V unbalanced 3-phase
delta
• Bonderized undercoat on cabinet with
baked enamel finish
• Top inlet and outlet openings
• Foam insulation
• Easily converted to single-phase at ter-
minal block (except for 208V with
6000 watt elements
• Drain valve
• Single-element heater, single-phase only
(see chart for dual-element options)
• UL-approved field conversion program
Factory-Installed
Terminal Block
Three-Year Limited Tank
Warranty
• Provides electrical service to heater and
connects to block
• Consult written warranty shipped with
water heater, or contact State for
complete information
Factory-Wired Controls
• Temperature control (adjustable from
110°F to 170°F on single-element;
120°F to 180°F on dual-element models)
For more information on State® contact:
State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800-365-0024 Toll-free USA
SCESS00106
August 2008R
Page 1 of 4
©2007 State Water Heaters Company
Download from Www.Somanuals.com. All Manuals Search And Download.
TOP VIEW
PCE 6 10MSA, PCE 10 10MSA
PCE 17 10MSA, PCE 20 10MSA
ALTERNATE OUTLET
OUTLET
3/4" (FEMALE) NPT
3/4"(FEMALE)
NPT*
3/4" NPT
RELIEF VALVE
OPENING
A
B
C
ELECTRICAL
CONNECTION
INLET
3/4" (FEMALE)
NPT
FRONT VIEW
PCE 6 10MSA, PCE 10 10MSA
PCE 17 10MSA, PCE 20 10MSA
OUTLET
3/4" (FEMALE)
NPT
OUTLET
3/4" (FEMALE)
NPT
INLET
3/4" (FEMALE)
NPT
INLET
3/4" (FEMALE)
NPT
“D”
“D”
3/4" NPT
RELIEF VALVE
OPENING
2 1/2"
JUNCTION
BOX
JUNCTION
BOX
2 1/2"
TOP VIEW
PCE 30 20LSA, PCE 40 20LSA,
PCE 50 20LSA
TOP VIEW
“B”
“B”
3/4" NPT
RELIEF VALVE
OPENING
“A”
“A”
“C”
DRAIN
VALVE
BRASS
DRAIN
VALVE
3 3/4"
3 3/4"
FRONT VIEW
PCE 30 20RTA – PCE 120 20RTA
FRONT VIEW
PCE 30 20LSA, PCE 40 20LSA,
PCE 50 20LSA
Page 3 of 4
©2008 State Water Heaters Company
SCESS00106
August 2008R
Download from Www.Somanuals.com. All Manuals Search And Download.
C O M M E R C I A L
SUGGESTED SPECIFICATION
The water heater(s) shall be State Patriot™ Model(s) ________, rated at _______ KW, _______ volts, _______ -phase, 60
cycle AC. Water heater(s) shall be listed by Underwriters Laboratories and meet or exceed the thermal efficiency and/or standby
loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1 shall be ________ gallon
capacity with a recovery capacity of ______ GPH at a temperature rise of ______°F with ______/______ upper/lower element
wattage. Heater(s) shall have 150 psi working pressure and be equipped with extruded high-density anode rod. All internal
surfaces of the heater(s) exposed to water shall be glass-lined with an alkaline borosilicate composition that has been fused to
steel by firing at a temperature of 1600°F. Electric heating elements shall be medium watt density with zinc-plated copper sheath
or Incoloy sheath _______________.
Each element shall be controlled by an individually mounted thermostat and high-temperature cutoff switch. The outer jacket
shall be a baked enamel finish and provided with a full-size control compartment for performance of service and maintenance
through a hinged front panel and shall enclose the tank with foam insulation.
Electrical junction box with heavy-duty terminal block shall be provided (except on 120V and 277V [no junction box on
PCE 6 10MSA thru PCE 20 10 MSA]). The drain valve shall be located in the front for ease of servicing. Heater tank shall
have a 3-year limited warranty as outlined in the written warranty. Fully illustrated instruction manual will be included.
For more information on State® contact:
State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015
800-365-0024 Toll-free USA
Page 4 of 4
©2008 State Water Heaters Company
SCESS00106
August 2008R
Download from Www.Somanuals.com. All Manuals Search And Download.
|