Sigma Portable Generator BSG26N User Manual

SIGMA  
STAND ALONE NTSC BLACK SIGNAL  
GENERATOR  
BSG26N  
OPERATOR'S MANUAL  
P.O. BOX 448  
1027 COMMERCIAL AVENUE  
EAST PETERSBURG, PA 17520-0448  
(717) 569-2681  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SIGMA ELECTRONICS, INC.  
BSG-26 SERIES  
INSTRUCTION MANUAL  
WARNING: To reduce the risk of fire or electric shock, do not  
expose this apparatus to rain or moisture.  
GENERAL:  
The BSG-26N and BSG-26P are Black Signal Generators which provide six (6) blackburst signal outputs. The  
outputs are driven from the same internal source to ensure system synchronization. The design of the units provides  
suitable operation for applications from complex total system timing to laying black on tape. The blackburst signal is  
digitally derived from a temperature compensated oscillator. These units provide a stable output and do not require  
any adjustments during operation. The outputs are present when power is applied.  
Superblack operation is selective via J1. With J1 jumper shorted across pins 1 and 2, the module will produce  
superblack on all outputs. Superblack can be used when building a Multi-Pass special effect. The superblack signal,  
approximately -7.5 IRE, provides a noiseless background that can be laid down on the tape for this application.  
The BSG-26N, NTSC version, provides outputs per RS-170A / SMPTE 170M standards. The BSG-26P, PAL  
version, provides outputs per CCIR 624-4 standards. Specifications are provided in the SPECIFICATIONS section.  
POWER:  
The BSG-26 Series accommodates a wide range of line voltage from 90 VAC minimum to 255 VAC maximum.  
The line frequency range is 50 to 60 Hz. The units utilize an IEC 320 inlet to accommodate the proper power cord set  
for the line voltage connectors used in any geographical area. The combination of the wide voltage range and  
universal inlet contributes to the diversity of applications where the BSG-26 will supply a dependable source of black  
signal. The module internally regulates the bus voltage to +5 VDC (U8) and -5 VDC (U9). Circuit protection is provided  
by an externally accessible fuse (Figure 1).  
FRAMES:  
The BSG-26 units are assembled in a stand-alone box. The metal enclosure provides desirable shielding from  
external EMI / RFI noise sources. See the section on SPECIFICATIONS for recommended operational conditions. The  
units are capable of rack mounting with the optional RMK-26 Rack Mount Kit. This 1RU rack mount does not require  
blank panels for unused portions. A total of three (3) Series 26 units may be mounted with a single RMK-26.  
CONNECTIONS:  
The connectors are located on the rear panel. BNC connectors are used for the six outputs. Each of the  
outputs are designed to drive a 75 Ohm load. The outputs must be terminated by a single end of line 75 Ohm  
termination to ensure proper signal level. Unused outputs do not require a 75 Ohm terminating resistor.  
1
2
3
4
5
6
FUSE  
T40mA  
100-240V~  
50-60Hz  
6W  
OUTPUTS  
CAUTION  
RISK OF ELECTRIC SHOCK  
DO NOT OPEN  
250V  
U
L
C
US  
BSG-26  
SIGMA ELECTRONICS, INC.  
REAR PANEL  
Figure 1  
2 of 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
JUMPERS:  
Jumpers are provided for custom configuration. No jumper changes for normal Black Signal operation. See the  
Service Manual for jumper details. Note: Jumpers selection to be performed by qualified personnel only.  
ADJUSTMENTS:  
Adjustments are provided for custom configuration. No adjustments are required for normal Black Signal  
operation. Note: Adjustments to be performed by qualified personnel only.  
SPECIFICATIONS  
OUTPUTS:  
BSG-26N: ........................................... (6) Blackburst, per RS-170A (NTSC), SMPTE 170M  
BSG-26P: ........................................... (6) Blackburst, per CCIR 624-4 (PAL)  
LEVELS: ............................................ In accordance with standards specified.  
SCH PHASE: ..................................... 0° ±5°  
SCH JITTER: ................................. < 2° p-p  
SETUP & SUPERBLACK: ................. Jumper Selection, +7.5, 0, -7.5 IRE  
MASTER CRYSTAL STABILITY: ......  
17.734475 MHz TCXO (PAL)  
14.318180 MHz TCXO (NTSC)  
Initial ....................  
vs. Time ...............  
vs. Temperature ...  
1 PPM  
1 PPM/Year  
1 PPM, 0° C to +50° C  
CONNECTORS: ................................. BNC  
POWER:  
VOLTAGE RANGE: ........................... 100 to 240 VAC (-10%,+6%) (90 to 255 VAC)  
LINE FREQUENCY: ........................... 50 to 60 (±5%, 47 to 63 Hz)  
POWER CONSUMPTION: ................ 6 Watts nominal (9 Watts max.)  
CONNECTOR: ................................... Power; IEC 320  
ENVIRONMENTAL:  
OPERATIONAL TEMPERATURE: ...  
+32° to +131° F (0° to +50° C)  
MECHANICAL:  
DIMENSIONS: ................................... 1.75” H x 5.5” W x 8.5” D (44.5 x 140 x 216 mm)  
SHIPPING WEIGHT: ......................... 4 lb. (1.8 kg)  
TECHNICAL MANUAL:  
Technical Manual is available upon request. See the Service Manual  
WARRANTY:  
Sigma Electronics, Inc. warrants that it’s products are free from defective material and workmanship at the  
time of shipment from Sigma Electronics. The products will possess the electrical characteristics as set forth in the  
specifications for a warranty period of five years. This warranty does not include any Sigma Electronics product or part  
thereof which have been subjected to misuse, neglect, improper installation, use in violation of instructions furnished,  
or accident. It does not extend to products that have been modified from original design outside the factory. Nor does it  
extend to units from which the serial number has been removed, defaced, or changed. Nor does it extend to  
accessories not of Sigma Electronics, Inc. manufacture.  
3 of 4  
All specifications, drawings, dimensions, weights and other details are subject to change without  
notification. Information is intended to give a general performance and operation guideline of the product.  
Sigma Electronics, Inc.; P.O.Box 448; 1027 Commercial Avenue; East Petersburg, PA 17520-0448  
Main Office: Tel: (717) 569-2681 Fax: (717) 569-4056  
REV6 DEC98  
BSG-26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SIGMA ELECTRONICS, INC.  
BSG-26 SERIES  
SERVICE MANUAL  
CAUTION  
These servicing instructions are for use by qualified personnel only. To reduce the risk of  
electric shock do not perform any servicing other than that contained in the operating instructions  
unless you are qualified to do so. Refer all servicing to qualified service personnel.  
Explanation of symbols used. The following symbols appear on the product.  
DANGER  
ATTENTION  
Protective Ground  
Fuse Replacement  
AC  
High Voltage  
Refer to Manual  
(earth) Terminal RISK OF FIRE REPLACE  
FUSE AS MARKED  
Power  
Read the IMPORTANT SAFETY INSTRUCTIONS before installing or operating this equipment. Keep this  
information in an accessible location for reference by all users. Follow all instructions in this manual for safe operation.  
JUMPERS:  
The following jumpers are located on the PCB inside the enclosure. They are provided for custom  
configuration of the BSG-26N and BSG-26P. The modules should not require any adjustments for normal Black Signal  
operation.  
J1 Superblack/Black Select, Default position, Pins 2-3 (Black), Optional position, Pins 1-2 (Superblack).  
J2 Setup On/Off, Default position 1-2 (Setup On, NTSC, BSG-26N), Position 2-3 (Setup Off, PAL, BSG-26P)  
J3 Subcarrier Phase Select, 0° or 180°, Default position is 0°, Opposite position is 180°  
ADJUSTMENTS:  
The following adjustments are located on the PCB inside the enclosure. They are provided for custom  
configuration of the BSG-26N and BSG-26P. The modules should not require any adjustments for normal Black Signal  
operation.  
C31 Subcarrier center frequency.  
R7 Sync./Setup Gain, Set per standards specified.  
R14 Subcarrier Null, Minimizes residual subcarrier on output signal.  
R20 Burst Gain, Set per standards specified.  
R22 Variable Subcarrier Phase Adjust, 180° SCH Phase adjust, See “JUMPER” section, jumper 3 options.  
R25 Subcarrier Symmetry, Provides minimum difference in duty cycle between 0° and 180° setting of J3  
DISASSEMBLY:  
NOTE: REMOVE THE POWER BEFORE DISASSEMBLY OF THE UNIT.  
Disassembly is not necessary for normal Black Signal operation.  
Tools needed:  
#1 Phillips head screw driver.  
Procedure: 1st, remove the four rear panel Phillips head machine screws, one per corner. 2nd, remove the  
electrical assembly by pulling the rear panel from the enclosure; the PCB is attached to the rear panel.  
TECHNICAL MANUAL:  
A manual including schematics, circuit description, parts list and setup guide is available upon request. This  
information is intended for the service of the unit. The units should be serviced by qualified personnel only. Sigma  
Electronics, Inc. recommends service to be performed by the Factory Service Center.  
4 OF 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Computer Monitor PN L601B User Manual
Shindaiwa Welder DGW400DM 380A User Manual
Smooth Fitness Treadmill FX4 User Manual
Snapper Lawn Aerator 4570 User Manual
Snapper Lawn Mower ZF2101DKU User Manual
Sterling Wheelchair AF XXX User Manual
Studio RTA Indoor Furnishings 402875 User Manual
Superior Indoor Fireplace sddv 35 40 User Manual
SV Sound Speaker PB13 User Manual
Sylvania TV VCR Combo 6724FDF User Manual