| Jump starter & Dc Power source   Models: PSJ-2212 One 22-Ah Battery   12V   PSJ-3612 Two 18-Ah Batteries 12V   PSJ-4424 Two 22-Ah Batteries 12/24V   InstRuctIon Manual   THIS PRODUCT HAS A SEALED LEAD-ACID BATTERY INSIDE THAT SHOULD BE KEPT AT FULL CHARGE FOR LONGER LIFE.   RECHARGE WHEN FIRST RECEIVED, AFTER EACH USE AND EVERY 3 MONTHS.   IMPORTANT SAFETY INSTRUCTIONS   Save These Instructions   NOTE: When the voltage on the clips exceeds 15 volts, the audio   important safety instructions   alarm will beep four times. If the cables are connected to a 24-volt   Someone should be within range of your voice or close enough to   system when the switch is in the 12V position, the audio alarm   come to your aid when you are working near a lead-acid battery.   will sound continuously. TURN off the jump starter immediately   Have plenty of fresh water and soap nearby in case battery acid   contacts skin, clothing, or eyes. If acid enters the eye area, rinse   with cold water for at least 10 minutes and get medical help   immediately.   or internal battery damage will occur.   NOTE: If the switch is in the 12V or 24V position or the jump   starter is connected to a battery for more than 5 minutes, four   beeps will sound. This is a reminder to turn the jump starter off   and/or disconnect from battery when it is not in use.   Do not smoke, or use matches or cigarette lighters, or allow any spark   or flame near the battery or engine.   10. After the engine starts, turn the rotary switch to the o (off)   position. Then disconnect the black clamp (-) and then the red   clamp (+) in that order. Store the clamps in the compartments   located on the sides of the case.   Never operate the power source unit if it has damaged lead wire or   clamps. Have the lead wire replaced by a qualified technician.   Wear complete eye and clothing protection when working with lead-   acid batteries.   11. Recharge the jump starter as soon as possible after use.   *NOTE: In the rare case of jump-starting a vehicle that has   a positive-grounded vehicle electrical system, connect the   NEGATIVE black clamp (-) to the negative terminal (-) of the   vehicle battery. Then connect the PoSITIVE red clamp (+) to an   unpainted and unmoving part of the vehicle chassis or engine   block. If you are unsure of the nature of the vehicle’s electrical   grounding system, check the owner’s manual of the vehicle. To   disconnect clamps, reverse order.   Do not permit internal battery in the jump starter to freeze. Never   charge a frozen battery.   handling warning   WARNING: Handling the cord on this product or cords associated with   this product, may expose you to lead, a chemical known to the State   of California to cause cancer and birth defects or other reproductive   harm. Wash hands after handling.   operating instructions   digitial display   Warning: Failure to follow instructions may cause   damage or an explosion. Read entire instruction manual   before use.   The display can be used to indicate a battery’s voltage when   connected to a battery or the percentage of charge in the jump   starter’s internal battery.   1. Turn ignition off before making cable connections.   With the switch in the off position, connect the clamps to the   vehicle’s battery and its voltage is displayed. Turn the jump starter’s   rotary switch to 12V, (or, for Model PSJ-4424, 12V or 24V) and the   combination of both internal and external batteries are shown.   2. Use in a well-ventilated area.   3. Keep clear of fan blades, belts, pulleys and other parts that may   cause injury.   4. Make sure the rotary power switch on the front panel is in the o   (off) position until clamps are connected to the vehicle battery.   If plugged into an 110V AC wall outlet, disconnect.   To read the internal battery’s charge status: Press the display button   to read the percentage of charge left in the internal battery. A fully   charged battery will read 100%.   5. To prevent sparking, NEVER allow clamps to touch together or   to contact the same piece of metal.   charging of internal battery with built-in 3-amp, automatic   charger.   6. Clamp the red clamp (+) to the positive terminal of the battery.   After removing the jump starter from the carton, charge it for a   minimum of 8 hours before using.   (for a negative grounded system.)*   7. Clamp the black clamp (-) to an unpainted and unmoving part   of the chassis or engine block. The 3-digit display will show the   voltage of the battery.   1. Make sure the rotary power switch on the front panel is in the o   (off) position.   8. If you have connected the clamps backwards, an audio alarm   will sound. Do NoT turn your jump starter on. This could cause   serious damage. Reverse the connections, and the audio alarm   will stop.   2. Plug extension cord into charger plug on the left side of the   jump starter. (Extension cord not included; must be purchased   separately.)   3. Plug the extension cord into 110V AC electrical wall outlet.   9. If no audio alarm sounds, turn the rotary switch to the 12V position.   (or, for Model PSJ-4424, switch to 12V or 24V.) The clamps are   now powered. Crank the engine. If the engine does not start within   5 – 8 seconds, stop cranking and wait at least 1 minute before   attempting to start vehicle again. (This permits the battery to cool   down.)   4. Charging of the internal battery could take up to 48 hours due to   age and condition of the battery. At full charge, the charger will   automatically drop into a float mode and maintain the battery at   full charge without damaging the battery. The jump starter can   be left plugged into the 110V wall outlet indefinitely to maintain   full power.   00-99-000686/0906   Download from Www.Somanuals.com. All Manuals Search And Download.   |