| PFD1/PFS1 – OPERATING INSTRUCTIONS   PUMP   PFD1/PFS1   OPERATING INSTRUCTIONS   SAINT-GOBAIN PERFORMANCE PLASTICS ASTI SAINT-GOBAIN PERFORMANCE PLASTICS ASTI   (Headquarters)   (Factory)   E.A.D.A.C. des Berthilliers   F-71850 CHARNAY LES MACON   Tel: 33. (0) 3.85.20.27.00   41, boulevard des Bouvets   F-92741 NANTERRE CEDEX   Tel: 33. (0) 1.55.68.59.59   Fax: 33. (0) 1.55.68.59.68   Fax: 33. (0) 3.85.29.18.48   SAINT-GOBAIN PERFORMANCE PLASTICS   7301 Orangewood Avenue   GARDEN GROVE, CA 92841   Phone: 1 (714) 630 5818   Fax: 1 (714) 688 2416   INDEX   03   DATE   27/09/01   N°   DC01020US   Download from Www.Somanuals.com. All Manuals Search And Download.   PFD1/PFS1 – OPERATING INSTRUCTIONS   Thank you for selecting a SAINT-GOBAIN PERFORMANCE PLASTICS ASTI model PFD1 AstiPure™   pump, series 2 (or PFS1: slurry applications).   I – General   I.1 – Introduction   The Model PFD/PFS is a pneumatically operated TEFLON® pump. There are no internal or external   metal parts.   The pump is designed for handling corrosive, inflammable and sterile fluids. It meets the requirements of   the semiconductor, pharmaceutical and chemical industries.   I.2 – Materials   All wetted parts are manufactured in TEFLON® PFA HP and PTFE.   Other parts are made of high-tech plastics such as PVDF, PEEK etc.   There are no metal parts.   I.3 – Operation   The pump is pneumatically operated; two bellows joined by a central shaft reciprocate horizontally. The   suction and delivery strokes alternate from one side of the pump to the other.   The pump is self-priming and has four balls, which seat on lip seals (check valves).   The pumping frequency of a bellows pump is much slower than an equivalent diaphragm pump and   results in an extended life for the bellows.   Pulsation dampers with wetted parts in TEFLON® PFA and PTFE are available as an option. This   dampens the pulse by approximately 65 to 80%. The pulsation damper for the PFD1/PFS1 pump is   AMC1/AMS1.   I.4 – Pump Data   Flow rate   2.5 GPM (600 l/h)   Discharge pressure   Suction head   58 PSI max. (4 bar)   10 feet water column (3 m)   Max. air consumption   Connections   Air connection   6 SCFM (10 m³/h) NTP   3/8”x1/2” or 10x13 mm TEFLON® flared tube or 1/2” MNPT thread.   1/4" I/D gas female thread   Tubing Æ3/32”x5/32” (2.5x4 mm) maximum   10 feet (3 m) < length < 20 feet (6 m)   4.5 lbs (2 kg)   Weight   Also available three larger capacity pumps with optional pulsation dampers:   PFD2/PFS2   PFD3/PFS3   PFD4/PFS4   Flow rate 5 US GPM (20 l/min)   Flow rate 12.5 US GPM (50 l/min)   Flow rate 25 US GPM (100 l/min)   AMC2/AMS2   AMC3/AMS3   AMC4/AMS4   II – Quick checklist   II.1 – Shipment   Pumps are cleaned and assembled in our clean room, then double sealed in plastic bags to ensure they   are not contaminated in transit. They are then packed in cartons with Polyethylene protection.   2/11   INDEX   03   DATE   27/09/01   N°   DC01020US   Download from Www.Somanuals.com. All Manuals Search And Download.   PFD1/PFS1 – OPERATING INSTRUCTIONS   II.2 – Reception   Upon receipt of the pump, please check that:   · · · The carton has not been damaged in transit. If there is any visible damage, immediately contact the   carrier.   The pump is not damaged. If there are signs of damage, you should report this immediately to   SGPPL ASTI or your local distributor.   An operating instruction manual has been included in each package. Please request another copy if   it has not been included.   III – Installation and Operation   III.1 – Testing   All pumps are tested with DI water at the factory in our clean room for:   · · · · Maximum flow rate with no back pressure   Minimum flow rate with no back pressure   Flow rate with 58 PSI (4 bar) discharge pressure   Checked for leakage   III.2 – Set up   The pump must be installed horizontally as shown on general arrangement drawing (see appendix   “APP 1 EXT”). This drawing also shows the overall dimensions of the pump etc.   The pump must be positioned on its feet. If not, the check valves will not seat correctly and the pump   may malfunction.   III.3 – Connections   III.3.1 – Air/Nitrogen connection   The pump must be connected to a clean dry air or nitrogen supply. On no account should the air/nitrogen   supply be lubricated, oil or water droplets will cause the shuttle valve to malfunction.   Minimum and maximum supply pressure must be between 29 and 72.5 PSI (2 and 5 bar).   For optimum pump operation, we recommend a supply pressure of 51 PSI (3.5 bar).   The ID of the tube supplying the dry air/nitrogen should not exceed 3/32” (2.5 mm). The tube length   between the pump and on/off valve should be between 10 feet minimum (3 m) and 20 feet maximum   (6 m).   When in aggressive conditions (acid vapors), it is advised to canalize outlet with a tube of minimum   ID 1/4” (6 mm).   The pneumatic on/off valve must be 3-way to ensure the shuttle valve on the pump resets itself when the   pump is switched off. The flow control valve must be positioned before the 3-way on/off valve   (see appendix “APP 1 CAB”).   A remote control box with on/off switch and needle valve (P/N 21 000 04) is available as an optional   extra.   3/11   INDEX   03   DATE   27/09/01   N°   DC01020US   Download from Www.Somanuals.com. All Manuals Search And Download.   PFD1/PFS1 – OPERATING INSTRUCTIONS   III.3.2 – Fluid connections   The pump is self-priming. The inlet is at the bottom and the outlet at the top.   Two optional fittings are available:   · PFD1 210 or PFS1 210: pump is supplied with flared fittings suitable for 3/8”x1/2” (10x13 mm)   TEFLON® tube. The tube needs to be flared prior to fitting using SGPPL ASTI forming tool   (P/N MF11013).   · PFD1 221 or PFS1 221: pump is supplied with 1/2” MNPT male threads on the inlet and outlet. We   recommend using TEFLON® tape when connecting female tube fittings to the PFD/S1 221 pump.   Both the inlet and outlet fittings can be rotated through 180 degrees if necessary, by loosening the nuts   on the inlet and outlet fittings. Then, retighten the nuts.   III.4 – Initial Tests and Adjustments   Before commissioning the pump, we recommend to test it dry with a supply pressure of 72.5 PSI   (5 bar) to ensure the system works correctly (See III.3.1 for the correct connections).   If the pump is cycling too quickly reduce the speed by adjusting the needle valve.   Before using the pump with chemicals please check:   · · · The body rings (P/N 2706, Mark L) and manifolds are tight,   The air/nitrogen supply is dry, clean and between 29 and 72.5 PSI (2 and 5 bar),   The inlet and outlet fluid connections are correctly fitted and tight.   IV – Applications   IV.1 – Chemical compatibility   All PFD/PFS pump wetted parts are manufactured in TEFLON® PTFE and PFA and are suitable for   pumping even the most corrosive concentrated chemicals: H2SO4, HNO3, HF, H3PO4, HCl, NH4OH, KOH,   NaOH, CH3COOH, TMAH, H2O2...   The viscosity of the liquids must be less than 1000 cpo.   PFD pumps can pump liquids containing particles up to 0.02” (0.5 mm).   Very abrasive liquids are not recommended.   Please call either the factory or your local distributor if you require information on chemical compatibility.   IV.2 – Contamination   The “all plastic” construction of the PFD/PFS pump ensures no ionic contamination of the chemical, even   if there is a bellows failure.   Due to the low frequency and amplitude of the bellows pump, SGPPL ASTI guarantees a lower level of   particle contamination when compared to a diaphragm pump.   IV.3 – Temperature range   The pump can handle liquids from 32°F (0°C) up to +212°F (100°C).   When the fluid temperature is greater than 140°F (60°C) you must frequently check that the body rings   (P/N 2706, Mark L) and manifolds are fully tight and that supply pressure is less than 43.5 PSI (3 bar).   For special applications call SGPPL ASTI or your local distributor.   4/11   INDEX   03   DATE   27/09/01   N°   DC01020US   Download from Www.Somanuals.com. All Manuals Search And Download.   PFD1/PFS1 – OPERATING INSTRUCTIONS   IV.4 – Applications   The PFD/PFS pump is a volumetric pump. The stroke volume is dependent on the flow rate and   discharge pressure.   In order to know the precise flow rate of the pump, a paddle wheel flow transmitter can be fitted on outlet.   For PFD1/PFS1 the part number of the flow transmitter is DP11013.   · Part number marked K (PFD1 210K or PFS1 210K) indicates that the pump will be supplied with   KALREZ® manifold (P/N 2745K, Mark G) and body O.rings (P/N 2739K, Mark H).   PFS1 pumps are equipped with valve seats without lip (P/N 2711A, Mark I) and bellows with rounded   spires (P/N 2613S, Mark F) in order to pump abrasive products (slurry).   Common applications are:   · Semiconductor Industry:   Transfer of ultrapure and corrosive chemicals.   Pump filter recirculation systems.   · Pharmaceuticals and Chemicals: Chemical injection and sampling.   IV.5 – Limitations of use   The standard pumping speed of the PFD1/PFS1 is about 135 strokes/min.   The following should NOT be part of the system:   · · · · Do not connect the pump inlet or outlet with air, nitrogen or liquid under pressure,   Lubricated and/or wet air/ nitrogen,   Air supply tubing greater than 3/32” (2.5 mm) ID,   Air line length between the pump and control valve less than 10 feet (3 m) and more than   20 feet (6 m),   · · · · · Air pressure less than 29 PSI (2 bar) or greater than 72.5 PSI (5 bar),   Inlet connection less than 3/8” (9 mm) ID,   Restricted suction side (valves, filters...),   Exceed the recommended liquid temperatures,   Pumping too viscous or abrasive liquids.   Any of the above may be detrimental to the normal operation and life expectancy of the pump and may   invalidate the warranty.   If the pump is being used with very corrosive chemicals or if it is left for extended periods not in use, we   recommend the system is emptied and flushed.   V – Maintenance   V.1 – Trouble Shooting   If the pump stops for any reason check:   · · The air/nitrogen supply,   That all valves in the chemical lines are open.   Before dismantling the pump, ensure the shuttle valve is in the correct position. Depress the manual   override on the shuttle valve (P/N 2701, Mark A) to re-position the shuttle.   5/11   INDEX   03   DATE   27/09/01   N°   DC01020US   Download from Www.Somanuals.com. All Manuals Search And Download.   PFD1/PFS1 – OPERATING INSTRUCTIONS   If the pump starts, check that the following was not the cause:   · · · The air/nitrogen connections (See III.3.1),   The air/nitrogen quality,   Has the pump been serviced correctly? (See V.2 Preventive maintenance).   Before dismantling the pump check the following:   · · · · The air/nitrogen supply is “OFF”,   The chemical and discharge lines are empty and there is no pressure,   All in line valves are closed,   You follow your local Health and Safety Regulations with regard to particular chemicals.   V.2 – Preventive Maintenance   V.2.1 – Continuous Operation   When the pump is used continuously, it is necessary to replace the following parts every year:   · · Shaft composite rings   Central shaft   Important: these parts should always be replaced together.   P/N 7135F   P/N 2615   During routine maintenance checks, examine the following parts and change them if necessary:   · · · · · · · · · Bellows   P/N 2613 (PFD) or 2613S (PFS)   P/N 2701   P/N 2725   P/N 2739   P/N 2745   P/N 2711 (PFD) or 2711A (PFS)   P/N 7220   P/N 7185   P/N 2712   Shuttle valve   Viton bellow O.ring   Body O.ring   Manifold O.ring   Lip seal   PTFEsleeves   Silencers   Ball valves   V.2.2 – Intermittent operation   If the pump is used intermittently, it is advised to replace all wearing parts every 18 months (shaft   composite rings and central shaft) and to check other parts (bellows, shuttle valve, lip seal...).   If the pump is left standing full of chemical for long periods all the Viton O.rings should be replaced.   V.3 – Comments   If the pump is used to pump hot chemicals in excess of 140°F (60°C) the preventive maintenance   schedule time scale should be divided by 2:   · · Every 6 months check as for continuous operation,   Every 9 months check as for intermittent operation.   The above is based on SGPPL ASTI's experience.   SGPPL ASTI cannot be held responsible for premature failures if the pump is misused or   damaged due to an incorrect application.   VI – Dismantling and Repair   Attention: Part numbers quoted in this manual are those used on a “standard” PFD/PFS pump. Before   ordering, please check the spare parts list, the section view of the pump and the part numbers table (see   encl. documents).   6/11   INDEX   03   DATE   27/09/01   N°   DC01020US   Download from Www.Somanuals.com. All Manuals Search And Download.   PFD1/PFS1 – OPERATING INSTRUCTIONS   VI.1 – How to dismantle   Before dismantling the pump, refer to the Maintenance schedule V.1, and proceed as follows:   · · · · Disconnect the air/nitrogen supply,   Remove the inlet and outlet connections (beware of any chemical droplets remaining on the inside),   Rinse the outside of the pump in DI water to remove all trace of chemicals,   Remove pump support screws.   VI.2 – Examination   To comply with your local Health and Safety Regulations it is essential the pump and all parts are   thoroughly cleaned both on the inside and outside.   See V.2 for the Preventive Maintenance Schedule.   To repair the pump, refer to schedules V.1 and V.2.1.   VI.3 – Stripping and assembling the pump   The SGPPL ASTI design ensures that the pumps are easy to strip and assemble.   The only tools required are a screwdriver to replace the shuttle valve (see VI.3.1) and a strap wrench to   remove body rings (P/N 2706, Mark L). All other items can be removed and replaced by hand. A tools kit   for the whole maintenance is available (P/N KPFD1), as well as maintenance kits   (P/N AIR PFD1, LIQ PFD1, and MEC PFD1), and a preventive maintenance box (P/N PM PFD1 or PM   PFS1). For more details on these kits, please report to appendix documents.   Please refer to drawing “APP 1 REF” to visualize marks and part numbers quoted hereafter.   VI.3.1 – Replacing the shuttle valve   The valve is easily removed from the outside:   1) Unscrew the 2 fastening screws – take care not to damage them,   2) Replace with a new factory assembled shuttle valve (P/N 2701, Mark A),   3) Carefully tighten the 2 fastening screws. Do not overtighten,   4) Test with compressed air/nitrogen. Re-tighten if necessary.   VI.3.2 – Replacing the bellows   To replace the bellows proceed as follows:   1) Remove shuttle valve (P/N 2701, Mark A) (see VI.3.1),   2) Unscrew exhaust silencers (P/N 7185),   3) Unscrew the 4 manifold nuts and remove the 4 balls valves (P/N 2712) – take care not to lose them,   4) Remove the 4 manifold O.rings (P/N 2745, Mark G),   5) Position the pump into a bench vice (tighten only over the core P/N 2708),   6) Unscrew the body ring (P/N 2706, Mark L) with a strap wrench while holding the PFA body,   7) Remove the pump body (P/N 7145, Mark K),   8) Now unscrew the bellows (P/N 2613 or 2613S, Mark F) from the central shaft (P/N 2615,   Mark D),   9) Replace with new bellows – moderately hand tighten,   10) To re-assemble follow the above but in reverse order from 8) to 1).   All TEFLON® PTFE and PFA parts are soft; please handle with care to avoid damage. Do not put them   down on their sealing surfaces.   To re-assemble the PFA bodies, hand tighten the body rings (P/N 2706, Mark L), and block them up by   giving 1/8 further turn with the strap wrench. Check that bodies are well positioned so that manifolds are   tight.   7/11   INDEX   03   DATE   27/09/01   N°   DC01020US   Download from Www.Somanuals.com. All Manuals Search And Download.   PFD1/PFS1 – OPERATING INSTRUCTIONS   VI.3.3 – Replacing the central shaft and shaft composite rings   Follow the same steps described in V1.3.2 until 8) then:   9) Remove the central shaft (P/N 2615, Mark D),   10) Remove the plastic caps (P/N 1028),   11) Remove the C-PEEK plate screws (P/N 2729) and the rings (P/N 1720),   12) Remove the 4 shaft composite rings (P/N 7135F) from plates (P/N 2709 and 2728, Marks B and C),   13) Clean the plates and the core (P/N 2708) by removing the dust from previous wear by O.rings,   14) Insert 4 new composite rings with tools from our tool kit (P/N KPFD1) as follows:   · Each of the 4 shaft rings (P/N 7135F) is composed of two parts: one O.ring and one sleeve   (Figure 1):   O.ring   Sleeve   7135F   Inner side   Outer side   Figure 1   · O.rings can be installed with the O.ring positioning tool P/N 1641.   To install the ring on the inner side of the plate (Figure 2), insert the longer side of the tool in the   plates (P/N 2709 and 2728, Marks B and C), as shown in the drawing. Then place the ring against   the O.ring positioning tool (P/N 1641) and insert it in the groove.   To install the ring on the outer side (Figure 3), insert the shorter side of the O.ring positioning tool   through the inner side of the plate, and place the ring against the positioning tool. Then insert the   ring in its groove.   Long   1641   Short   Short   Long   Inner side   Outer side   Figure 2   Figure 3   8/11   INDEX   03   DATE   27/09/01   N°   DC01020US   Download from Www.Somanuals.com. All Manuals Search And Download.   PFD1/PFS1 – OPERATING INSTRUCTIONS   · Squeeze the sleeve into a “bean” shape, then insert it in the sleeve insertion tool P/N 2680   (Figure 4):   Step 3   2680   Step 2   Step 1   Figure 4   · While holding the O.ring positioning tool (P/N 1641) against the plate, place the sleeve insertion tool   (P/N 2680) into the other side and use the push-button to release the sleeve free on the O.ring   (Figures 5 & 6):   1641   Outer side   2680   Inner side   Push   Figure 5   Figure 6   9/11   INDEX   03   DATE   27/09/01   N°   DC01020US   Download from Www.Somanuals.com. All Manuals Search And Download.   PFD1/PFS1 – OPERATING INSTRUCTIONS   · Use the pick (P/N 1643) to correctly position the sleeve in its groove. Be careful not to damage the   sleeve (Figure 7):   1643   Figure 7   · Repeat this operation for the 4 sets of rings.   15) Fit the plates and the body rings (P/N 2706, Mark L) on the core (tighten moderately the screws   P/N 2729), insert first the O.ring (P/N 1720) under the screw head,   16) Fit new plastic caps (P/N 1028) so that tightness between the core and the plates is ensured,   17) Important: lightly wipe the central shaft and shaft composite rings with silicon grease (Molykote   111) before re-assembly. Then insert the central shaft without turning it when threaded part reaches   the O.rings,   18) To re-assemble follow the above instructions but in reverse order.   VI.3.4 – Replacing the PTFE sleeves   Follow the same procedure as for VI.3.3 until 14); after replacing the composite rings, remove the PTFE   sleeves (P/N 7220) from the groove with a blunt pointed instrument. Clean and re-assemble the new part.   A pump that was not originally fitted with PTFE sleeves can be equipped with sleeves. In this case, you   need to change the plates (P/N 2709 and 2728, Marks B and C).   VI.3.5 – Replacing the bellow and body O.rings   After removing the bellows (see V1.3.2, step 8), remove the bellow Viton O.rings (P/N 2725) and the   body O.rings (P/N 2739, Mark H). Then carefully replace the new ones without scratching the surface   of the bellows (P/N 2613 or 2613S, Mark F) or housing (P/N 7145, Mark K).   VI.3.6 – Replacing the manifold O.rings   Follow point VI.3.2, steps 3) and 4). Carefully replace the manifold O.rings (P/N 2745, Mark G). Take   care as these parts are fragile, especially the elbow connectors.   10/11   INDEX   03   DATE   27/09/01   N°   DC01020US   Download from Www.Somanuals.com. All Manuals Search And Download.   PFD1/PFS1 – OPERATING INSTRUCTIONS   VI.3.7 – Replacing other parts   When dismantling the pump or control unit for service, components found damaged should be   replaced. Alternatively, the pump/control unit can be returned to your distributor or SGPPL   ASTI for examination, estimate, and repair.   Important: Please indicate what chemical was handled, the frequency of use, and the reason for   returning the pump.   A receipt note “Conditions of use” is at your disposal. Do not hesitate to ask for it when needed.   An estimate for repair will be proposed to you and the pump will be returned to you within one week from   date of its acceptance.   VII – Warranty   SGPPL ASTI pumps and accessories are warranted for all parts and labor against faulty workmanship   (return to factory) for one year from delivery date (9000 hours of use).   SGPPL ASTI is not responsible for damage to its products through improper installation, maintenance,   use or attempts to operate them beyond their mechanical capacity, intentionally or otherwise, or for   unauthorized repair.   SGPPL ASTI shall not be liable for any indirect, special, incidental or consequential damages resulting   from the use, failure or malfunction of any product.   ® Du Pont's registered trademarks   ™ Saint-Gobain Performance Plastics Asti trademark   11/11   INDEX   03   DATE   27/09/01   N°   DC01020US   Download from Www.Somanuals.com. All Manuals Search And Download.   PFD1/PFS1 – SPARE PARTS LIST   SAINT-GOBAIN PERFORMANCE PLASTICS ASTI   41 boulevard des Bouvets   F- 92000 NANTERRE   Tel: +33 (0) 1.55.68.59.59   Fax: +33 (0) 1.55.68.59.68   PUMPS PFD1 (SERIES 2) & PFS1   PART   DESIGNATION   QUANTITY   NUMBER   PFD1 210   PFD1 221   PFS1 210   PFS1 221   1028   1720   CAP   4 4 2 2 4 4 4 4 2 2 4 4 FLAT PLATE O RING   2559A   2559AZ   2560A   2560AZ   2613   2613S   2615   2701   2701F   2706   2706T   2708   2709   2711   PFD1 MANIFOLD TUBE 1/2”   PFD1Z MANIFOLD TUBE 1/2”   PFD1 MANIFOLD PIPE THREAD 1/2 MNPT   PFD1Z MANIFOLD PIPE THREAD 1/2 MNPT   PFD1 BELLOW WITH INSERT   PFS1 BELLOW ROUNDED SPIRES WITH INSERT   CENTRAL SHAFT   SHUTTLE VALVE   SHUTTLE VALVE PE UHMW SHUTTLE   BODY RING   2 2 2 2 2 2 2 1 1 1 2 2 1 1 2 1 1 1 2 2 1 1 1 1 1 2 2 1 1 4 1 1 1 2 2 1 1 4 ETFE BODY RING   CORE   BLADED PLATE   PFD1 LIP SEAL   2711A   2712   2725   2728   2729   2739   2739K   2745   2745K   7135F   7139   PFS1 SLURRY VALVE SEAT   BALL VALVE Æ10   VITON BELLOW O.RING   TAPPED PLATE   C-PEEK 5x50 PLATE SCREW   FEP BODY O.RING   KALREZ BODY O.RING   FEP MANIFOLD O.RING   KALREZ MANIFOLD O.RING   SHAFT COMPOSITE O.RING   VITON PNEUMATIC O.RING   PFA BODY   1/4” EXHAUST SILENCER   PTFE SLEEVE   PVDF NUT TUBING 1/2” OD   4 4 2 1 4 2 2 4 4 4 6 2 2 2 2 4 4 2 1 4 2 2 4 4 4 6 2 2 2 2 4 2 1 4 2 2 4 4 4 6 2 2 2 2 4 2 1 4 2 2 4 4 4 6 2 2 2 2 7145   7185   7220   MS11013   INDEX   03   DATE   27/09/01   N°   DC01020US   Download from Www.Somanuals.com. All Manuals Search And Download.   PFD1/PFS1 – MAINTENANCE KITS   SAINT-GOBAIN PERFORMANCE PLASTICS ASTI   41 boulevard des Bouvets   F- 92000 NANTERRE   Tel : +33 (0)1.55.68.59.59   Fax : +33 (0)1.55.68.59.68   PUMP PFD1 (SERIES 2) – MAINTENANCE KITS   PART   DESIGNATION   QUANTITY   NUMBER   AIR PFD1 LIQ PFD1 MEC PFD1 PM PFD1   1028   1720   2613   2615   2701   2711   2712   2725   2729   2739   2745   7135F   7139   7185   7220   CAP   4 2 FLAT PLATE O RING   PFD1 BELLOW WITH INSERT   CENTRAL SHAFT   SHUTTLE VALVE   LIP SEAL   2 2 1 1 4 4 2 2 2 4 4 6 2 2 1 1 4 4 2 BALL VALVE Æ10   VITON BELLOW O.RING   C-PEEK 5x50 PLATE SCREW   FEP BODY O.RING   FEP MANIFOLD O.RING   SHAFT COMPOSITE O.RING   VITON PNEUMATIC O.RING   1/4” EXHAUST SILENCER   PTFE SLEEVE   2 4 4 2 2 PUMP PFS1 – MAINTENANCE KIT P/N “PM PFS1”   PART   DESIGNATION   QUANTITY   NUMBER   1028   1720   2613S   2615   2701   2711A   2712   2725   2729   2739   2745   7135F   7139   7185   7220   CAP   4 2 2 1 1 4 4 2 2 2 4 4 6 2 2 FLAT PLATE O RING   PFS1 BELLOW ROUDED SPIRES WITH INSERT   CENTRAL SHAFT   SHUTTLE VALVE   VALVE SEAT   BALL VALVE Æ10   VITON BELLOW O.RING   C-PEEK 5x50 PLATE SCREW   FEP BODY O.RING   FEP MANIFOLD O.RING   SHAFT COMPOSITE O.RING   VITON PNEUMATIC O.RING   1/4” EXHAUST SILENCER   PTFE SLEEVE   INDEX   03   DATE   27/09/01   N°   DC01020US   Download from Www.Somanuals.com. All Manuals Search And Download.   2x E   4x 7135F   B 4x 1028   2x M   2x L   2x 7185   2x 7220   2708   D C 4x 2712   4x 2729   2 x 2725   4x 1720   4x G   4xI   2x J   2x F   A 6x 7139   2x H   Dessiné par :   Vérifié par :   En date du :   j.Be   2x K   En date du :   24/09/01   DESIGNATION   SAINT-GOBAIN PERFORMANCE PLASTICS ASTI   41 Boulevard des Bouvets   ASTIPURE Pump 1   REFERENCE   92000 Nanterre - France   Tel: +33 (0)1 55 68 59 59   INDICE   TM   Fax: +33 (0)1 55 68 59 68   pure   APP 1 REF   03   Download from Www.Somanuals.com. All Manuals Search And Download.   PART NUMBERS TABLE   Connec-   tion   Piloting   PF (standard)   PR   Fluid   Size   1 Sealing   Option   A B C D E F G H I J K L M 2701   2709   2826   2826   2728   2827   2827   2615   2828   2828   2613   2745   2739   2711   7145   2706   MS11013   1 1 2829   2829   PO   D S 1 1 2613S   2711A   210   221   2559A   2560A   K 2745K 2739K   Z F P/N + "Z"   2706T   2701F   IMPORTANT:   The following reference combination is not relevant:   PO - 1 --- - F   A : Shuttle valve   B : Bladed plate   C : Tapped plate   D : Central shaft   E : Stopper   F : Bellow   1 210 F   PR S   K G : Manifold O.Ring   H : Body O.Ring   I : Lip seal   J : Manifold   Piloting:   Fluid:   Option:   K : Pump body   L : Body ring   M : Nut   F Standard   R Recirculation   O No piloting   D S Standard   Slurry   Z F TEFZEL nut   HF shuttle valve   Sealing:   Connection:   - FEP   210 Flare Fitting Ø 10x13 or 3/8"x1/2"   K Kalrez   221 Pipe thread Ø 1/2" MNPT   Date: 27/09/01   Index: 02   APP 1 REF   Download from Www.Somanuals.com. All Manuals Search And Download.   260.4mm   10.25"   7mm   Ø .28"   90mm   3.54"   120mm   4.72"   FM   Dessiné par:   Validé par:   DATE:02/05/00   SGPPL ASTI   DESIGNATION   41 Boulevard des Bouvets   F-92741 Nanterre Cedex   FRANCE   Pump ASTIPURE 1   REFERENCE   INDICE   Tel: +33 (0)1 55 68 59 59   Fax: +33 (0)1 55 68 59 68   00   APP 1 EXT   Download from Www.Somanuals.com. All Manuals Search And Download.   AstiPure™ PFD1 / PFS1 pump flow rate characteristics   4,5   4 Air supply 5 bar   3,5   3 Air supply 4 bar   Air supply 3 bar   2,5   2 1,5   1 Air supply 2 bar   0,5   0 50   150   250   350   450   550   650   750   Flow rate (l/h)   Download from Www.Somanuals.com. All Manuals Search And Download.   REFOULEMENT FLUIDE   FLUID OUTLET   Air 2 à 5 Bar   2m Max   VANNE DE REGLAGE   VALVE   VANNE D' ARRET   STOP   Ø2.5x4mm Max - 6m Max   ASPIRATION FLUIDE   FLUID INLET   FM   Dessiné par:   Validé par:   DATE:09/05/00   SGPPL ASTI   DESIGNATION   41 Boulevard des Bouvets   F-92741 Nanterre Cedex   FRANCE   ASTIPURE Pump 1   REFERENCE   INDICE   Tel: +33 (0)1 55 68 59 59   Fax: +33 (0)1 55 68 59 68   00   APP 1 CAB   Download from Www.Somanuals.com. All Manuals Search And Download.   |