| Undercounter Dishwasher   PRODUCT MODEL NUMBERS   OVERALL DIMENSIONS   RUD6050R   24" (61 cm)*   23-7/8" (60.6 cm)   Electrical: 120-volt, 60 Hz, AC-only, 15 or   20 amp. electrical supply. Use copper wire only. A   time-delay fuse or circuit breaker and separate   circuit is recommended.   33-7/8"   (86 cm) min.   Water: A hot water line with 20-120 psi   (138-862 kPa) water pressure. Water temperature   must be 120°F (49°C) at dishwasher. Use 3/8" O.D.   copper tubing with compression fitting (1/2"   minimum plastic tubing is optional but not   recommended). Use a 90° elbow with 3/8" N.P.T.   external pipe threads on one end to connect to   water inlet valve. Do not solder within 6" (15.2 cm)   from water inlet valve.   * to front of   door frame   20-3/4"   (52.7 cm)   CABINET OPENING DIMENSIONS   Drain: Use the new drain hose supplied with your   dishwasher. If this is not suitable, use a new drain   hose with a maximum length of 12 feet (3.7 m)   that meets all current AHAM/IAPMO test   standards, is resistant to heat and detergent, and   fits the drain connector of the dishwasher. Must   have a high drain loop 20 inches (50.8 cm) above   the subfloor or floor. Connect drain hose to waste   tee or disposer inlet above drain trap in house   plumbing and 20 inches (50.8 cm) minimum   above the floor. An air gap must be used if the   drain hose is connected to house plumbing lower   than 20 inches (50.8 cm) above subfloor or floor.   Use 1/2" minimum I.D. drain line fittings.   24" (61 cm)**   *Measured from the lowest point on the   underside of countertop. May be reduced   to 33-7/8" (86 cm) by removing wheels   from dishwasher.   **Minimum, measured from narrowest point   of opening.   24" (61 cm)   34" (86.4 cm) min.*   Corner location: Requires a 2" (5.1 cm)   minimum clearance between the side of the   dishwasher door and wall or cabinet.   6"(15.2 cm)   4" (10.2 cm)   6"(15.2 cm)   A side panel kit is available from your dealer for   installing your dishwasher at end of cabinet.   4"   4"   (10.2 cm)   (10.2 cm)   Do not install dishwasher over carpeted floor.   10"   2-1/2"   (6.4 cm)   2-1/2"   (25.4 cm)   (6.4 cm)   2"   (5.1 cm)   5" (12.7 cm)   5" (12.7 cm)   2"   (5.1 cm)   Water line entering through the   left side of opening in shaded   areas makes connection easier.   Minimum 1/2" (12,7 mm) hole.   Drain hose and power supply line entering through the right   side of opening in shaded areas makes connection easier.   Drain hose size: 1-1/2" (3.8 cm)   Power supply line hole-direct wired: 3/4" (1.9 cm)   Power supply line hole-with plug: 1-1/2" (3.8 cm)   CUSTOM FRONT PANEL DIMENSIONS (Framed)   Cut door panel to clear access panel when   These panels fit only models with frames around the door and access panels.   door is in open position ạ.   7/32"   (5.6 mm)   door closed   door panel (front view)   side view   ạ door pivot   NOTE: Access panel is wider than door panel.   door panel   (side view)   3/8"   (9.5 mm)   door opened   23 5/16" (59.2 cm)   18 21/32"   (47.4 cm)   access panel   (front view)   access panel   1"   4 7/16"   (11.3 cm)   (25.4 mm)   7/32" (5.6 mm) thick   All edges routed to 7/32" (5.6 mm) thickness.   22 31/32"   (58.3 cm)   top view   7/32"   (5.6 mm)   1/4"   (6.4 mm) min.   access panel frame   Because Whirlpool Corporation policy includes a continuous commitment to improve   our products, we reserve the right to change materials and specifications without notice.   Dimensions are for planning purposes only. For complete details, see Installation   Instructions packed with product. Specifications subject to change without notice.   Ref. 8535436   02-02-06   Download from Www.Somanuals.com. All Manuals Search And Download.   |