| INSTALLATION INSTRUCTIONS   Rotary Flat Mount   Model: RFM   AUSTRALIA, NEW ZEALAND, OCEANIA   EUROPE   Swallow House,   NORTH AMERICA   3130 East Miraloma Avenue   Anaheim, CA 92806 USA   USA and Canada –   (DISTRIBUTOR)   P.O. Box 295   Shilton Industrial Estate,   Shilton, Coventry, England CV79JY   Phone: +44 (0) 2476 614700   Fax: +44 (0) 2476 614710   Mordialloc Victoria 3195   Australia   Phone: 039586 6330   Phone: 800-368-9700   Fax: 800-832-4888   Other Locations – Phone: (001)-714-632-7100; Fax: (001)-714-632-1044   ©Premier Mounts 2008   9531-009-041-03   Download from Www.Somanuals.com. All Manuals Search And Download.   RFM   Parts List   This mount is shipped with all installation hardware and components. Make sure that none of these parts are   missing and/or damaged before beginning installation. If there are parts missing and/or damaged, please stop and   contact Premier Mounts (800) 368-9700.   Universal Mounting Brackets (Qty 2)   Rotating Universal Bracket Bar (Qty 1)   5/16” x 3” Lag Bolts - wooden studs   only (Qty 6)   5/16” Flat Washers   (Qty 6)   M6 Knurl Knob   (Qty 1)   Griplate™ (Qty 8)   Installation Tools   Phillips Head Screw Driver   Pencil   Soft Material/Blanket   Tape Measure   1/2” Socket and Wrench   Drill Gun   Level (Supplied)   M5 Allen Wrench (Supplied)   5/32” Allen Wrench (Supplied)   1/4” Drill Bit (Pilot Holes)   Thread Depth Indicator (Supplied)   Masonry Drill Bit (Concrete Applications - Commercially Available)   Installation Instructions   Page 3   Download from Www.Somanuals.com. All Manuals Search And Download.   RFM   (Qty 8)   (Qty 8)   M4 x 16   M4 x 25   M6 x 20   (Qty 8)   (Qty 8)   M6 x 30   M6 x 45   (Qty 8)   M5 x 12   M5 x 16   (Qty 8)   (Qty 8)   M8 x 20   M8 x 25   (Qty 8)   (Qty 8)   M5 x 20   M5 x 25   M5 x 50   (Qty 8)   (Qty 8)   (Qty 8)   M8 x 30   (Qty 8)   (Qty 8)   M6 x 16   (Qty 8)   M8 x 35   M8 x 45   (Qty 8)   M8 x 70   (Qty 4)   Page 4   Installation Instructions   Download from Www.Somanuals.com. All Manuals Search And Download.   RFM   The nylon spacers may be stacked to achieve proper spacing.   9/16" Nylon spacers   (Qty 8)   1/4" Nylon spacers   (large)   (Qty 8)   1/2" Nylon spacers   (large)   Nylon sleeves   (Qty 8)   (Qty 12)   5/16" Flat washers   (metal)   (Qty 8)   1" Nylon Spacers   (Qty 8)   1/4" Nylon spacers   (small)   (Qty 8)   Installation Instructions   Page 5   Download from Www.Somanuals.com. All Manuals Search And Download.   RFM   Thread Depth Indicator   1. Insert the thread depth indicator (supplied) through the thread inserts found on the back of the flat panel to make sure the inserts   measure the same full depth and mark it (Figure 1).   2. Locate the correct diameter screw for the thread insert. Compare your marking to the screws (supplied).   3. If your selected screw is longer than the marking on the thread depth indicator, DO NOT USE this screw.   4. The screw length must not bypass the marking. Select another screw size (Figure 2 and 3), until you find one that comes closest to   your mark without going past.   Inverted Flat   Panel Display   Marking the   Depth   Thread Insert   Thread Depth   Indicator   Screw   Screw   Marking   Marking   Thread Depth   Indicator   Thread Depth   Indicator   Page 6   Installation Instructions   Download from Www.Somanuals.com. All Manuals Search And Download.   RFM   Mount Installation   Step 1   Step 2   Step 3   Determine where the mount lo-   cation will be. Use a stud finder   to locate the nearest wall stud.   Once the stud has been located, use a pencil   to mark the spot.   Using a 1/4” drill bit, drill the upper mount-   ing hole where the mark was made.   For ease of installation, it is recommended that two people perform the installation. One person should hold the   mount while the other person installs the lag bolt and washer. Making sure that the mount is level, the person not   holding the mount must mark and drill the second mounting hole and secure the second lag bolt and washer.   Step 6   Step 5   Step 4   Insert two (2) 5/16” x 3” lag bolts   and washers into the mounting holes   and tighten (see WARNING: below   Place a level (supplied) on the top   rail and make sure that the mount is   level. Once the mount is level, Drill   pilot holes in the lower mounting   slots and install two (2) 5/16” x 3”   lag bolts and washers into the mount-   ing holes and tighten.   After the holes have been pre-drilled,   line up the mounting slot openings   with the pre-drilled holes.   Do NOT over-tighten lag bolts when attaching the mount to the wall. Improper installation may result in personal   injury or damage to property.   If the studs are 12” (304.8mm) apart, use three (3) 3” (76.2mm) lag bolts for the top rail and three (3) 3” (76.2mm)   lag bolts for the lower rail. If the studs are 16”(406.4mm), 18” (457.2mm) or 24” (609.6mm) apart, use two (2) 3”   lag bolts for the top rail and two (2) 3” lag bolts for the lower rail.   Installation Instructions   Page 7   Download from Www.Somanuals.com. All Manuals Search And Download.   RFM   Concrete Mounting   Concrete anchors must be used for concrete installation. They can be purchased at your local hardware store. The   mounting surface must be a minimum 6” thick.   1.   2.   3.   4.   5.   6.   7.   8.   Begin by placing the mount into position against the wall, keeping it level.   Mark off four holes to be used for securing the mount.   Next, drill holes using a masonry bit for your anchors (recommended masonry bit).   Insert a commercially available concrete anchor into each hole (recommended 3/8” wedge anchors).   If necessary, a hammer can be used to lightly tap each anchor into place so that they are flush with the wall.   Once all of the anchors are in place, move the wall bracket into position.   Attach the nut onto the threaded shaft that is protruding from the wall.   Do not tighten until all nuts are in place.   Universal Mounting Bracket Assembly   1.   2.   Place the universal bracket bar and the universal brackets on a flat surface.   Slide the universal brackets onto the universal bracket bar (as shown below) with the set screws facing up. At this   time, do not tighten the set screws that are located on the universal bracket.   3.   4.   Place the display on a soft, flat surface, face-down. Next, place the universal bracket assembly on the back of the   display, with the universal brackets resting directly over the display mounting points.   Once the desired position has been determined, place the Griplate™ washers over each mounting point and secure   them using the appropriate hardware (see Page 5).   For the two upper mounting points, the Griplate™ flat side must be facing up. For the two lower mounting points, the   Griplate™ flat side must be facing down.   5.   At this time, center the universal bracket bar and tighten the set screws that are located on the universal brackets.   M8   M5   Universal Mounting Brackets   M6   M4   Set Screw   Universal Bracket Bar   Griplate™   Griplate™   IT WILL TAKE TWO PEOPLE TO COMPLETE THE NEXT INSTALLATION STEP.   Page 8   Installation Instructions   Download from Www.Somanuals.com. All Manuals Search And Download.   RFM   6.   Lower the universal bracket bar with attached   display into the cradle (as shown to the left).   Nylon   Sleeve   After loosening the tension bolts, be sure that the   nose piece is held together tightly before rotating.   Knurl Knob Mounting Point/M6 x 12mm Security Head and   M6 Lock Washer Mounting Point.   7.   Insert an M6 Knurl Knob/M6 x 12mm Security   Head and M6 Lock Washer into the knurl knob/   security screw mounting point and tighten.   To access the knurl knob/security screw   location while the display is attached, the   RFM must be rotated to the “portrait”   position (vertical position   8.   Tighten the two (2) Phillips head screws (located   on the side of the mounting block) once the final   position is attained.   Installation Instructions   Page 9   Download from Www.Somanuals.com. All Manuals Search And Download.   RFM   Display Orientation   The RFM will allow the user to adjust the display a full 360°.   BEFORE ROTATING THE RFM, MAKE SURE THAT THE M6 KNURL KNOB IS SECURELY FASTENED   TO THE RFM. ALSO, PLEASE MAKE SURE YOU ALLOW ENOUGH CABLE AND WIRE CLEARANCE   FOR FULL ROTATION.   M6 Knurl Knob   1.   To adjust the RFM, rotate the display either   clockwise or counter-clockwise.   2.   Tighten   the   two   Phillips   head locking screws (see Step 8,   Page 10).   Technical Specifications   All measurements are in inches (mm).   Page 10   Installation Instructions   Download from Www.Somanuals.com. All Manuals Search And Download.   RFM   Warranty   PREMIER MOUNTS   LIMITED LIFETIME WARRANTY   What and Who is Covered by this Limited Warranty and for How Long   Premier Mounts warrants this product to be free from defects in material and workmanship for the lifetime of   the original owner of this product. The limited warranty is valid only for the original purchaser of the product.   What Premier Mounts Will Do   At the sole option of Premier Mounts, Premier Mounts will repair or replace any product or product part that is   defective. If Premier Mounts chooses to replace a defective product or part, a replacement product or part will   be shipped to you at no charge, but you must pay any labor costs.   What is Not Covered; Limitations   PREMIER MOUNTS DISCLAIMS ANY LIABILITY FOR DAMAGE TO MOUNTS, ADAPTERS,   DISPLAYS, PROJECTORS, OTHER PROPERTY, OR PERSONAL INJURY RESULTING, IN   WHOLE OR IN PART, FROM IMPROPER INSTALLATION, MODIFICATION, USE OR MISUSE   OF ITS PRODUCTS.   PREMIER MOUNTS DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, IN-   CLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR-   POSE. PREMIER MOUNTS IS NOT RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL   DAMAGES, INCLUDING BUT NOT LIMITED TO, INABILITY TO USE ITS PRODUCTS OR LA-   BOR COSTS FOR REMOVING AND REPLACING DEFECTIVE PRODUCTS OR PARTS. SOME   STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE-   QUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO   YOU.   What Customers Must Do for Limited Warranty Service   If you discover a problem that you think may be covered by the warranty you MUST REPORT it in writing to   the address below within thirty (30) days. Proof of purchase (an original sales receipt) from the original con-   sumer purchaser must accompany all warranty claims. Warranty claims must also include a description of the   problem, the purchaser’s name, address, and telephone number. General inquiries can be addressed to Premier   Mounts Customer Service at 1-800-368-9700. Warranty claims will not be accepted over the phone or by fax.   Premier Mounts   Attn: Warranty Claim   3130 E. Miraloma Avenue   Anaheim, CA 92806   How State Law Applies   THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER   RIGHTS WHICH VARY FROM STATE TO STATE.   Installation Instructions   Page 11   Download from Www.Somanuals.com. All Manuals Search And Download.   |