Powerware P93 (9330-20) UPS
Features
Ideal applications
Ī iSeries 870 and 890
Ī pSeries 655, 670 and 690
Ī Enterprise Storage Server Model 800
Ī Cluster Server 1650
P93 features
Ī UPS is pre-architected, tested and
optimized for eServer and storage
applications
Ī Pre-installation site evaluation*
Ī Includes UPS installation and
start-up service*
Ī Output distribution with breakers,
cables and receptacles
Ī ProActive 1-year service plan
Ī Exclusive 5-year onsite warranty
offered through IBM with
IBMSERV coordination
UPS benefits
Ī Maximum availability – with true
double-conversion online design,
the proven technology that is
used for the most mission-critical
applications in the world
Designed specifically to meet the high-availability
needs of critical 24x7 applications for small to
medium-size business, the Powerware P93 delivers
enhanced system reliability and the highest
efficiency ratings of any online UPS in the 20 kVA
range. The P93 also contains high-end features and
benefits that only existed in larger capacity UPS,
until now.
Superior cooling design
The superior cooling design of the Powerware P93
draws from Powerware’s extensive, almost 40 years
of industry and product development experience.
This design, which features redundant fans, ensures
that more thermally sensitive areas are cooled first.
Ī Maximum efficiency – the
Powerware P93’s advanced design
features efficiency of up to 93%,
the highest for a double-conver-
sion online UPS in its kVA range
Comprehensive communications and user
interface
Ī Maximum performance – the
Powerware P93 delivers the high-
est performance by using digital
signal processing, true pulse-
width-modulation and maximum
IGBT responsiveness. This
The advanced features of the Powerware P93
include:
A large display, mimic and control panel is
ergonomically situated for operator interface with
the unit. The soft keypad helps guide the operator
through all menus and setups. A dedicated
micro-processor had been designed and engineered
to provide full-featured monitoring and extensive
alarm history. It allows for additional communica-
tion options like Internet accessibility, Ethernet,
network links, and modems.
Digital signal processing and pulse-width
modulation
True pulse-width modulation is achieved through
the use of digital signal processing, which enables
the IGBTs to works at their highest capacity,
increasing system reliability and ensuring perfect
power on the output.
provides easy setup, drift-free
operation and a pristine output
*When purchased with Powerware Field
Installation, PN 103003671, IBM PN 97P3604
Internal battery
Built-in control area network (CAN)
The Powerware P93 comes with internal batteries
that provide up to 17 minutes of backup at full
load. The batteries are easily accessible and main-
tained through front access slide-out trays. DC
Expert Plus™ internal battery management system
significantly enhances battery life.
An integral internal and external Control Area
Network (CAN) is incorporated into the Powerware
P93 that assists in seamlessly integrating peripherals
and options, controllable from the control panel.
It also reduces the internal wiring connections
required therefore increasing overall system reliability.
Download from Www.Somanuals.com. All Manuals Search And Download.
DC Expert Plus™ Built-in Battery Monitoring
Real-world business applications require a complete range of battery management and testing features, including battery runtime remaining, lifetime remaining,
battery health, and notification, to help make critical decisions, from scheduling preventive maintenance to load shedding. Advances in firmware, digital
technology and battery monitoring techniques enable the Powerware P93 to offer sophisticated battery management features, previously available only in
expensive add-on systems. By ensuring optimal battery health and availability, DC Expert Plus raises the reliability of the Powerware P93 far beyond any other
UPS in this kVA range.
DC Expert Plus advanced features include:
Ī
Powerware Battery Lifetime Monitor uses measures of chronological time, number of battery discharges, battery temperature, and system loading
to determine battery lifetime remaining.
Ī
Ī
Battery Runtime Remaining Monitor uses system loading plus internal sensing points for voltage and current data to calculate runtime remaining.
Advanced Battery Management (ABM®) uses patented three-stage charging technique that not only increases battery service life, but also optimizes
recharge time.
Ī
Ī
Ī
Battery Circuit Test (BCT) performs a periodic test of the battery string to ensure that there are no open circuits that would jeopardize battery
performance and system availability.
Temperature Compensated Charging (TCC) monitors the battery temperature and through sophisticated algorithms adjusts the rate of charge,
compensating for the ambient temperature to prolong the life of the battery.
Intelligent Battery Protection (IBP) automatically adjusts the shutdown voltage of the batteries based on the length of the AC outage. This prevents
severe battery discharge if the system is lightly loaded.
Intelligent Communications
The intelligent communications capability of the Powerware P93 family of UPS means improved reliability, easier network power management and expanded
network communications. With both hardware and software communications options, Powerware provides the right communications solution for your specific
situation.
LanSafe
LanSafe version 5 delivers comprehensive support including graceful, remote shutdown of UPS systems and network monitoring tools via serial, USB, and network
connectivity options. LanSafe's exclusive SafetyNet Technology provides Network Shutdown functionality and enables network administrators to shut down the
most critical equipment last.
Powerware Extensions for IBM Director
Powerware Extensions for IBM Director provide seamless integration of Powerware UPSs into the Director management system. The Extensions for IBM Director
simplify network management tasks for critical elements of server power protection. System administrators can easily monitor, diagnose, configure, set alarms,
schedule self-tests, check battery, gather inventory information, and control Powerware UPSs network wide from a single console within IBM Director.
PowerVision®
PowerVision power management software can monitor up to 64 network devices, provide data archiving and analysis to pre-
vent power problems, and offers sophisticated notification, plus Modbus® connectivity. Through its easy-to-use graphical user
interface, PowerVision provides critical information about the power, network-wide, in real time.
FORESEER®
FORESEER environmental monitoring software puts an end to worries about risks to your critical foundation equipment and
systems. From air conditioners to water cooling systems, generators to UPS, FORESEER gives you up-to-the-minute information about any system or device
that is fundamental to your system availability. Plus, with its unique data archiving capabilities, FORESEER can identify potential problems before they occur,
and notify you so you can implement a solution before a crisis.
ConnectUPS Adapters
Powerware’s ConnectUPS-X and communications adapters provide a self-contained link between the UPS and the Ethernet
LAN/WAN. Using HTTP, Telnet or SNMP, you can easily monitor, manage, and shut down or reboot remote UPS-protected
servers, routers, hubs and other key network devices in a controlled manner. These adapters are also compatible with many
third-party network management software packages.
Connectivity - what you need by application
Solution
zSeries
iSeries
pSeries
xSeries
Storage
Networking
LanSafe software
x
x
x
x
x
x
x
x
LanSafe software & ConnectUPS MultiServer card, IBM FC 2933
NetWatch software & ConnectUPS Web/SNMP card, IBM FC 2934
IBM Director Snap-in
PowerVision software
FORESEER Software
x
LPARS1
x
x
x
x
x
x
x
x
x
x
x
x
ConnectUPS relay card & AS400 cable, IBM FC 2936
x
NOTE: One (1) X-Slot relay card and interface cable included with P93. 1. Use ConnectUPS Web/SNMP/xHub card, IBM FC 2934 to support LPAR (POWER 4 Chip Set) servers. For pSeries configurations: each LPAR
needs a network connection and will install Powerware provided NetWatch or LanSafe V software.
Download from Www.Somanuals.com. All Manuals Search And Download.
P93 Options
ProActive service – additional year(s) plan description
Ī 7x24 corrective maintenance coverage
Ī 7x24 annual performance check
Ī Annual power protection audit
Ī 7x24 remote monitoring advance response
Ī Monthly UPS performance report with web access to account information and site service activity
Powerware
Part Number
155102012-001
155102013-001
IBM
Feature Code
7001
IBM
Part Number
97P2657
Per P93
Minimum
Maximum
Concurrent with UPS purchase
Non-concurrent to UPS purchase
0
0
4
4
7002
97P2658
Connectivity
ConnectUPS X-Slot Web/SNMP/xHub card (10/100Mb)
The ConnectUPS-X Web/SNMP/xHub card provides real-time UPS monitoring and control of power throughout both 100Mb and 10Mb networks. When used
in conjunction with NetWatch Client software, it also provides graceful shutdown of the operating system of up to 255 computers powered by a single UPS.
The advanced features of the ConnectUPS-X include:
Ī Real-time, enterprise-wide monitoring provides valuable information for analysis of critical power conditions and problem identification
Ī Supports 100Mb and 10Mb Ethernet networks
Ī Built-in three ports switching hub adds three 10/100Mb network connections with no additional expense
Ī Monitoring via Web using computer (through standard Web Browsers, e.g. Internet Explorer and Netscape). PDA or cell phone provides easy, anywhere,
anytime access
Ī Monitoring via SNMP using Network Management Software packages (e.g. Tivoli, CA Unicenter and HP Openview)
Ī Analysis of chronic power problems and determination of trends through data logging and sophisticated graphic tools
ConnectUPS MultiServer Card
The ConnectUPS MultiServer card is an X-Slot connectivity device that provides serial connection to up to five computers for unattended, graceful shutdown
and power monitoring. The card operates in conjunction with LanSafe software (included with UPS). The advanced features of the MultiServer card include:
Ī Real-time monitoring of critical power parameters
Ī Graceful, unattended shutdown of multiple computers
Ī Maximizes uptime of more critical loads through operation in tandem with load segment feature of UPS
Ī Supports simple signaling (relay contacts) through additional DB-9 port
Relay Interface Card
The Powerware Relay Interface card is an X-Slot connectivity device that provides monitoring of UPS status through isolated, dry contact, Form-C relays.
It also provides the interface for AS/400 computers as well as many industrial applications. The advanced features of the Relay Interface card include:
Ī Isolated, dry contact, Form-C relays for “utility failure”, “low battery”, “UPS alarm /OK” or “on bypass”
Ī User-selectable “normally open” or “normally closed” contacts
Ī Remote shutdown of UPS through integrated shutdown function
Ī Hot-swappable – UPS maintains power to critical applications while changing cards
Powerware
Part Number
103002974-5501
05146447-3901
103003564
IBM
Feature Code
2934
IBM
Part Number
53P4619
04N7027
97P3886
Per P93
Minimum
Maximum
ConnectUPS X-Slot Web/SNMP card
ConnectUPS X-Slot MultiServer card
ConnectUPS Relay Interface card & cable
0
0
0
2*
2*
2*
2933
2936
*Maximum combination of FC 2933, 2934, 2936 and other ConnectUPS X-Slot card options is two. ConnectUPS cards are installed onsite and concurrently with P93 startup by
Powerware Service Technician. Customer responsible for software installation.
Output connections
Three (3) NEMA non or locking receptacles (outlets) with breakers and connectors. Each connector shall be on a cord with maximum length of 50 feet.
Choose from:
pSeries
pSeries
zSeries
Feature Code
5-15R duplex
5-20R duplex
L5-15R
IBM Plug Type
iSeries Feature Code
1412, 1413, 2960 + 9082
Part Number
86G7648
Feature Code
Part Number
31L7061, 2, 4
4
-
7
9800
-
-
-
-
-
-
2960 + 9083, + 9082
31L7067, 8
L5-20R
-
-
-
-
-
L5-30R
6-15R
L6-15R
6-20R
L6-20R
L6-30R
-
5
10
29
11
12
-
1410, 1403, 1411, 1451, 1452, 1457, 2961 & 9082
1414, 1416, 1453, 1454, 1458
1400, 1401, 1423
-
-
-
-
183576, 4, 3
186G7878, 9
9909, 9833
-
-
-
-
31L7070, 1
-
-
-
-
-
1404, 1406, 1428
1424, 1426
11F0113, 4
Powerware
Part Number
103003673
IBM
Feature Code
9881
IBM
Part Number
97P2660
Per P93
Minimum
Maximum
Output power cords (NEMA)
0
6*
*Hardware installed onsite and concurrent to P93 installation.
Download from Www.Somanuals.com. All Manuals Search And Download.
Extended Battery Cabinets
Powerware offers a full line of battery cabinets for the Powerware P93.
Ī
Battery cabinets may be daisy-chained together for extended battery runtimes,
(up to 2).
Ī
Ī
Ī
Ī
Slide trays and modular battery packaging makes periodic servicing easy.
Cabinets are UL 1778 listed.
Ī
Ī
Integral configuration, which line up and match, is standard.1
Flame retardant batteries meet UL 94V2 for computer room installations.
Wiring installation.2
Front-access-only enhances servicing and installation.
Manufacturer-supplied wiring with quick disconnects provides
plug-and-play capability for line-up and match configurations.
A DC rated circuit breaker in each battery cabinet allows
multiple battery strings to be serviced independently of each
other, assuring back up power is always available to the UPS
Quick disconnects between battery tray assemblies reduce
battery maintenance time.
Removable battery slide-out tray assembles provide “front
access only” and reduce battery maintenance time.
1. Battery cabinets can be configured as line up and match or
remotely located. Customer must provide wiring for remotely
located cabinets. 2. If concurrent to P93 Field Installation,
Powerware PN 103003671, IBM PN 97P3604.
Battery runtimes (in minutes)
iSeries
890
pSeries
670
Storage
2105
Cluster
870
655
690
1350 1600
with
expansion
8 way 32 way standard enclosure
3 I/O 32 way 1 I/O 3 I/O
7 kW 10.5 kW 14 kW 6.8 kW 4.9 kW 8.3 kW 3.2 kW 6.4 kW 9.6 kW 6.5 kW 3.2 kW 10.5 kW 6.4 kW 13.8 kW
CEC + CEC + CEC +
I/O I/O I/O
10 kVA 15 kVA 20 kVA 16 way 16 way 32 way 1 I/O 2 I/O
1
2
3
node nodes nodes up to
Contact
Powerware
Internal battery
(1) External
battery cabinet
(2) External
45
90
26
65
90
17
48
75
48
98
79
31
75
110
240
400
50
27
70
96
49
110
240
400
26
65
90
50
17
48
75
150
240
110
180
108
172
110
180
battery cabinets 155
166
130
Contact Powerware for runtime, application or configuration assistance.
Calculating runtime - a guide
Typical runtime is 15 minutes
Formula (runtime in minutes) = [business + (2 x system shutdown) + safety]
Business = _____
Shutdown ____ x 2 = _____
Safety = _____
Total = _____
Powerware
Part Number
A13031
IBM
Feature Code
6635
IBM
Part Number
97P2663
Per P93
Minimum
Maximum
External Battery Cabinet
0
2
Additional options
Ī
Ī
Ī
Ī
Input/output galvanic isolation
Voltage matching transformers
Remote status panel
Remote EPO button
Download from Www.Somanuals.com. All Manuals Search And Download.
Powerware P93 Specifications
Options
Cabinet
ProActive
Service
X-Slot
X-Slot
X-Slot
Relay
P93
EBC
Web/SNMP Multi Server
Output power cords
9880 9881
IBM feature code
IBM part number
Input Voltage
Output voltage
Input/output frequency
Input voltage range
Minimum
Maximum
Rectifier input
Bypass input
Nominal amps
AC output
Nominal
10 minutes
Battery
6635
7001
7002
2934
2933
2936
97P2653 97P2654
97P2663
97P2657 97P2658
53P4619
04N7027
97P3886
97P2659 97P2660
Volts
Volts
Hz
208
208
50/60
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Volts
Volts
Amps
177
228
52
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Quantity
(2) 60 A,
3-phase,
Amps
55.5
-
-
-
-
-
-
-
4-wire,
IEC-309,
460R9W
with
Quantity
(3). See
FC 9881
Amps
Amps
55.5
69.4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
description.
breakers
and
connec-
tors.
Nominal voltage
Max. charge
voltage @ 25°C
Charge current
Nominal discharge current Amps
Total cell count
Volts
288
-
288
-
-
-
-
-
Volts
Amps
340
7
52
-
-
-
-
340
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
144
144
System efficiency
@100% load
@75% load
@50% load
%
%
%
92.4
92.7
92.9
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Maximum heat dissipation
BTU/hr. (x1000)
kcal/hr.
3.9
990
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Inverter efficiency
(full load)
%
94
-
-
-
-
-
-
-
Physical attributes (max.)
Width
Height
Depth
Weight installed
in/cm
in/cm 45/114
in/cm 31/79
22/56
17/52
45/114
38/97
200/90
4 @
17/52
45/114
31/79
600/272
6 @
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
50 ft. (maximum cord)
20 lb. each connector
lb/kg 958/435
.5/.2
.5
.5/.2
6 @
Point loading
Min/max qty per P93
lb/kg 160/73
-
50/230
1/1
145/100
0/2
N/A
0/4
N/A
0/4
N/A
0/2
N/A
0/2
N/A
0/2
-
-
1/1
0/6
Powerware
WORLDWIDE HEADQUARTERS
8609 Six Forks Road
Raleigh, NC 27615 U.S.A.
Toll Free: 1.800.925.4426
EUROPE/MIDDLE EAST/AFRICA
Denmark: 45.3677.7910
Finland: 358.9.452.661
France: 33.1.60.12.74.00
Germany: 49.7841.6660
Italy: 39.02.66.04.05.40
ASIA PACIFIC
Australia/NZ: 612.9878.5000
China: 86.21.6350.0606
HK/Korea/Taiwan: 852.2745.6682
India: 91.11.2649.9414 to 18
Singapore/SEA: 65.6829.8888
LATIN AMERICA
Argentina: 5411.4343.6323
Brazil: 55.11.3616.8500
México: 5255.9171.7777
CANADA
Ontario: 416.798.0112
Norway: 47.23.03.65.50
Sweden: 46.8.598.940.00
United Kingdom: 44.1753.608.700
Revised 01/04
Reprint 01/04
Download from Www.Somanuals.com. All Manuals Search And Download.
|