TURBOPOWER® OIL ꢂ PACKAGED WATER HEATER
POLYSHIELD® POLYMER-LINED STORAGE TANK
TANK SERIES 125 GALLONS HORIZONTAL
Dimensions
(inches)
Blower
Motor
Recovery gph ꢀ
Shipping
Weight
lbs
Model
Number
Input
Btu/h
Gph
#2 Oil
40°- 120°F 40°- 140°F
A
B
J ꢁ
HP
Volt/Ph/Amps
250 PHE 125A-TPO
500 PHE 125A-TPO
750 PHE 125A-TPO
1000 PHE 125A-TPO
1250 PHE 125A-TPO
1500 PHE 125A-TPO
250
500
200
400
199,000
399,000
1.4
2.8
4.3
5.7
7.2
8.6
24
24
27
27
27
27
4
5
6
8
8
8
17
17
17
17
17
17
1/3
1/2
1/2
1/2
1/2
1/2
970
990
115/1∅/8
115/1∅/10
115/1∅/10
115/1∅/10
115/1∅/10
115/1∅/10
750
600
600,000
1070
1110
1350
1360
1000
1250
1500
800
800,000
1000
1200
1,000,000
1,200,000
ꢀ Recoveries based on 83% thermal efficiency. ASHRAE 90.1 compliant for efficiency and standby loss.
ꢁ "J" dimension is for the burner housing only.
Dimensions are in inches unless otherwise specified.
For standard and optional equipment, see form PV 6006.
VENTING REQUIREMENTS
STANDARD ELECTRICAL REQUIREMENTS
-.02" TO -.06" W.C. (NEGATIVE PRESSURE)
CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS.
MOTOR VOLTAGE:
ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED
UPON THE VENT CONNECTION DIAMETER EXCLUSIVELY.
FOR PROPER SIZING, CONSULT VENTING SUPPLIER.
208V, 230V, AND 460V MOTORS ARE AVAILABLE BUT WILL
REQUIRE A SEPARATE 120V/2 amps CONTROL CIRCUIT OR
AN OPTIONAL CONTROL CIRCUIT TRANSFORMER.
PVI RESERVES THE RIGHT TO CHANGE THE DESIGN
AND SPECIFICATION WITHOUT NOTICE.
PVI INDUSTRIES, LLC
FORT WORTH, TEXAS 76111
Product is patented in the U.S., Canada, and Mexico.
PV 5458 04/05