3.0 INSTALLATION
Also, the flat braided grounding wire(s) on the Model 57x should
be attached to the grounded metal frame of the device being protect-
ed. If it is not possible to attach it to the equipment being protected,
contact Patton Technical Support (See Section 1.1).
Model’s 57x and 58x surge protectors are easy to install and are
designed to operate transparently to your network. This section
describes cohnnection procedures for both models.
3.1 PRODUCT APPLICATIONS
3.1.2 BARRIER APPLICATION (MODEL 58x)
Both Models 57x and 58x protect all eight pins on the modular
RJ-45 Cat-5 interface, and work in environments with data rates up to
100 Mbps. The following descriptions will give you a general guideline
for installing the units in your Cat-5 environment.
The Model 58x is a more robust protector than the Model 57x,
and is designed for use as a barrier protector on LAN equipment in
campus networks. Applications include: cable runs between buildings;
cable runs between floors on multi-story structures; and as a higher
capacity replacement for the Model 57x.
3.1.1 POINT-OF-USE APPLICATION (MODEL 57x)
The Model 58x is also well suited for use in severe lightning areas,
heavy industrial environments, and situations where heavy machinery
is in the direct vicinity of sensitive LAN equipment and cabling. Figure
2 (below) shows a typical application for the Model 58x. For best
results, the braided grounding strap(s) on the Model 58x should be
attached to the grounded metal frame of the device being protected.
When installation is made at a barrier, such as an external wall, the
braided strap must be connected to a nearby electrical ground. If a
nearby electrical ground cannot be located, contact Patton Technical
Support (See Section 1.1).
The Model 57x is designed for installation on LAN equipment in a
typical office environment, as in Figure 1, below. For best results, the
Model 57x should be connected as close as possible to the communi-
cation port of the device to be protected.
Exterior Wall
Typical RS-422/485 Application
Electrical Panel
Model 570
To Other
or 580
Building or
Wall
Exterior Wall
Electrical Panel
To Other
Building or
Wall
Model 57x or 58x
Model 580
Typical 100Base-T Application
Model 570 or 580
Workstation
Workstation
Model 57x or 58x
Local Hub
57x or 58x
Figure 2. Barrier Application for 58x
Workstation
Controller
Model 570 or 580
Figure 1. Model 57x58x Point of Use Application
4
3
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2 INSTALLATION PROCEDURES
3.2.2 Connecting the Model 58x at a Barrier (Wall,
Building, Entrance, etc.)
In order to operate as designed, the Model 57x and 58x must be
connected correctly to your Cat-5 network. For the safest installation,
please read all the instructions below and follow them very carefully.
1. Disconnect the UTP cable from the wall jack or patch panel jack.
3.2.1 Connecting the Model 57x or 58x to an I/O Port
2. Install the Model 58x between the UTP line and the jack. This
installation requires a straight through Cat-5 patch cable with
modular RJ-45 male connectors.
1. Turn off equipment power and disconnect the existing connection
between the UTP cable and the equipment’s I/O port.
Note: It doesn’t matter which port the UTP cable plugs into on the
rack, ss long as the input is directly above or below the correspon-
ding output.
2. Install the surge protector between the incoming UTP line
and the protected equipment, as in Figure 3, below. This
installation requires a straight through Cat-5 patch cable with
modular RJ-45 male connectors . Use shortest length possible.
3. Connect the ground braid(s) to the rack frame according to Figure
4 connected to earth ground. Do not lengthen the ground strap
or section describes connection procedures for both models.
Connection
to chassis
ground
Cat. 5 patch
cable to pro-
tected
4. Connect the rack structure frame directly to the earth ground if it is
not already connected. The best way to make this ground con-
nection is to attach a thick braided metal strap earth ground to a
metal panel, a wall plate screw or an electrical panel or subpanel,
using a hex nut or ground screw. Pay close attention to the impor-
tant note in Figure 4. If you cannot locate a nearby electrical
ground, contact Patton Electronics Technical Service (see Section
1.1)
equipment
Cat. 5 input
from network
Figure 3. Installation of Model 57x /58x Surge Protectors.
Caution: Surge energy may run both directions on the ground
strap. To provide the best protection, it is essential that the sup-
plied ground strap on the 57x/58x is connected to the chassis
ground of the protected device. Do not lengthen the ground strap
or connect to a ground other than a chassis ground unless
instructed to do so by Patton Technical Support.
Note: The ports are bidirectional. Therefore, the input cable must
be directly across from the output cable.on the Model 57/58x.
3. Locate a metal chassis ground. This is often a hex screw on a D-
shell or an AUI connector. Sometimes, a metal backpanel is
attached with screws, one of which can be used with chassis
grounding. If you cannot locate a chassis ground equipment on
your equipment, contact Patton Technical Support (See Section
1.1) to discuss an alternate grounding solution.
4. Connect the braided ground strap directly to chassis ground con-
nection you have located (see Figure 3, above). The best way to
make this ground connection is to attach the braided metal strap
using a hex nut or screw on your protected device.
Caution: Surge energy may run both directions on the ground
strap. To provide the best protection, it is essential that the sup-
plied ground strap on the Model 57x/58x is connected to the chas-
sis ground of the protected device. Do Not lengthen the ground
strap or connect to a ground other than chassis ground unless
instructed to do so by Patton Technical Support.
5
6
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX A
SPECIFICATIONS
APPENDIX B
INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) COM-
PLIANCE
Environment: Category-5 Interfaces that utilize the RJ-45
connector, including RS-422, 423, 10Base-
T, Token Ring, Fast Ethernet, 100Base-T,
100Base-T4 and ATM
Meets IEC standards 801.2, 801.4 and 801.5 (CE Mark)
Effective January 1996 the European Economic Community will
require that all electronic devices be tested and comply with all appli-
cable International standards relating to the product type and category
of use. Electromagetic Compatibility Directive 89/336/EEC specifically
addresses communication line surge protection devices, since con-
formity to immunity standard EN50082-1:1992 is mandatory. The
EN50082-1:10992 standard incorporates International Organization for
Standardization (ISO) publications 801.2 and 801.4, which describe
Electrostatic Discharge and Electrical Fast Transient requirements.
ISO 801.5 describes Surge Immunity Requirements and is expected to
be adopted as a mandatory requirement under EN50082-1 by the
Technical Committee. in 1996. Any protector sold into the international
community must meet these standards. This device has been tested*
and found to comply with these standards as evidenced by its CE
mark.
Connectors: RJ-45 Female
Response Time: Clamped to 13V after 0.1µS
Characteristic Impedance: 100 Ohms
NEXT Loss (worst pair): Better than -40 dB at 100 MHz
Surge Clamping Voltages: Model 57x: 13 V max with 1 KV Input;
Model 58x: 15 V max with 2 KV Input
Surge Rating: IEC 801.5 Standard Level
DC Clamping Voltages: Common Mode to Gnd, 7.5 V (each line)
@ 50 mA; Differential mode, 8.1 V (per
pair) @ 50 mA
IEC 801-5 Threat Levels as a Function of Class
Sym. Lines Coupling Mode
Class
Insertion Loss: Less than 0.4 dB (including connector) at all
Line-GND, Zs=42 Ohms
frequencies
1
2
3
4
5
1.0 kV
24 A
1.0 kV
24 A
2.0 kV
48 A
(n/a)
(n/a)
4.0 Kv
95 A
Return Loss: Better than 14 dB on both models
Group Delay: None, 1 MHz to 100 MHz
Series Resistance: Less than 400 milliohms
Grounding: External ground strap provides separate
unit-ground to chassis-ground contact
Wave
Forms
(1.2 x 50 µs)
(1.2 x 50 µs)
PC Board Dimensions: 7.0” x 3.0”
Figure B-1. IEC Threat Levels as a Function of Class.
Actual Panel Dimensions: 3.47” x 19.0” x 1.1”
Standard Temperatures: 0 - 500C/32 - 1220F
Flame Retardance: Plastic cases meet UL 94-V0 standard
*Note:
All test results are for the Model 57x/58x alone, not including
any external patch cables that are connected to the unit.
7
8
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX C
APPENDIX C (continued)
EIA/TIA TSB-40A COMPLIANCE
TSB-40A COMPLIANCE TESTING RESULTS
TYPICAL ATTENUATION MEASUREMENT
The Model 57x/58x series surge protectors have been designed to
conform to stringent EIA/TIA TSB-40 standards as required for all
Category-5 connecting hardware. These standards specify the capaci-
tance and near end cross-talk (N.E.X.T) to insure proper operation of
ALL connected equipment. Specific test results are shown in the
tables on the following pages*.
Freq
MHz
Pins: 1-2
dB
Pins: 3-6
dB
Pins: 4-5
dB
Pins:7-8 Spec
dB
dB
1
4
8
10
16
20
25
35.25
62.5
100
0.0
0.1
0.0
0.0
0.1
0.1
0.0
0.0
0.2
0.4
0.0
0.1
0.1
0.0
0.1
0.1
0.0
0.1
0.1
0.3
0.0
0.1
0.1
0.1
0.1
0.2
0.1
0.2
0.3
0.4
0.1
0.0
0.1
0.0
0.0
0.0
0.0
0.0
0.0
0.3
0.1
0.1
0.1
0.1
0.2
0.2
0.2
0.2
0.3
0.4
TSB-40A COMPLIANCE TESTING RESULTS
TYPICAL NEAR-END CROSSTALK MEASUREMENT
SOURCE/VICTIM PAIRS
FREQ
MHz
1-2/3-6
dB
1-2/4-5
dB
1-2/7-8
dB
3-6/4-5
dB
3-6/7-8
dB
4-5/7-8
dB
SPEC
dB
Figure C-3. Attenuation Measurements for Patton Model 57x
1
4
8
10
16
20
25
31.25
62.5
100
82.0
74.0
69.0
85.0
77.0
71.0
85.0
85.0
83.0
83.0
79.0
78.0
77.0
75.5
74.0
57.0
78.0
68.0
62.8
61.0
56.0
57.0
53.0
52.0
44.5
40.5
84.0
73.0
67.0
66.0
61.0
66.0
58.0
54.6
46.0
42.0
82.0
71.0
64.0
63.0
59.0
56.0
56.0
53.0
47.0
49.0
>65
>65
62
60
56
54
52
50
44
67.0 69.0
63.0 66.0
65.5 64.0
62.0 62.0
62.0
Freq
MHz
Pins: 1-2
dB
Pins: 3-6
dB
Pins: 4-5
dB
Pins:7-8 Spec
dB
dB
56.1
46.0
56.0
45.0 48.0
40
1
4
8
10
16
20
25
35.25
62.5
100
0.1
0.1
0.0
0.1
0.1
0.1
0.0
0.0
0.1
0.4
0.0
0.1
0.1
0.1
0.1
0.2
0.1
0.1
0.2
0.3
0.1
0.0
0.0
0.1
0.1
0.0
0.1
0.0
0.1
0.4
0.1
0.1
0.1
0.1
0.1
0.2
0.1
0.1
0.2
0.3
0.1
0.1
0.1
0.1
0.2
0.2
0.2
0.2
0.3
0.4
Figure C-1. N.E.X.T. measurements for Patton Model 57x
SOURCE/VICTIM PAIRS
FREQ
MHz
1-2/3-6
dB
1-2/4-5
dB
1-2/7-8
dB
3-6/4-5
dB
3-6/7-8
dB
4-5/7-8
dB
SPEC
dB
1
4
8
10
16
20
25
31.25
62.5
100
77.0
70.0
67.0
85.0
76.0
70.0
85.0
85.0
85.0
85.0
83.0
73.0
72.0
81.0
68.0
54.0
79.0
68.0
62.1
61.0
57.0
58.0
53.2
51.0
45.0
42.0
83.0
73.0
67.0
66.0
61.0
63.0
58.0
55.0
46.0
41.4
81.0
70.0
64.0
62.0
58.0
56.0
55.0
53.0
48.0
49.0
>65
>65
62
60
56
54
52
50
44
Figure C-4. Attenuation measurements for Patton Model 58x
67.0 68.0
62.0 65.0
69.0 65.0
59.0 62.0
61.0
57.0
44.0 45.0
57.0
51.5
40
Figure C-2. N.E.X.T. measurements for Patton Model 58x
*Note: All test results are for the Model 57x/58x alone, not including any
external patch cables that are connected to the unit.
9
10
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX C (continued)
Appendix C (continued)
TSB-40A COMPLIANCE TESTING RESULTS
TYPICAL RETURN LOSS MEASUREMENT
TSB-40A Compliance Testing Results
TYPICAL INSERTION LOSS MEASUREMENT
Pin Number:
DC Resistance
Milliohms
Freq
MHz
Pins: 1-2
dB
Pins: 3-6
dB
Pins: 4-5
dB
Pins:7-8 Spec
dB
dB
1
2
3
4
5
6
7
8
180
190
180
190
180
120
190
180
1
4
8
10
16
20
25
31.25
62.5
100
34.0
38.0
39.0
38.0
34.0
33.7
31.0
28.1
21.0
17.0
28.0
38.0
41.0
41.0
35.0
33.0
30.0
27.0
22.0
21.0
28.0
45.0
42.0
39.0
33.0
31.0
34.0
28.0
22.0
18.2
29.0
43.8
42.0
39.5
33.0
31.6
30.0
27.8
22.0
17.8
23
23
23
23
23
23
14
14
14
14
Figure C-7. Patton Model 57x Series Insertion Loss Measurement
Figure C-5. Return Loss Measurements for Patton Model 57x
Pin Number:
DC Resistance
Milliohms
Freq
MHz
Pins: 1-2
dB
Pins: 3-6
dB
Pins: 4-5
dB
Pins:7-8 Spec
dB
dB
1
2
3
4
5
6
7
8
180
180
180
190
190
120
180
160
1
4
8
10
16
20
25
31.25
62.5
100
28.0
38.0
39.0
38.0
35.0
33.0
31.0
29.0
21.8
17.2
28.0
38.4
43.8
44.0
38.0
34.0
31.0
28.0
22.0
19.3
29.0
47.0
41.0
38.0
30.0
31.0
29.0
27.0
21.0
16.7
30.0
44.5
41.2
38.7
33.4
31.0
28.3
28.0
21.0
17.3
23
23
23
23
23
23
14
14
14
14
Figure C-8.Patton Model 58x Series Insertion Loss Measurement
Figure C-6. Return Loss measurements for Patton Model 58x
11
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Dear Valued Customer,
Thank you for purchasing Patton Electronics products! We do
appreciate your business. I trust that you find this user manual helpful.
We manufacture one of the widest selections of data communica-
tions products in the world including CSU/DSU's, network termination units,
powered and self-powered short range modems, fiber optic modems, interface
converters, baluns, electronic data switches, data-line surge protectors, multi-
plexers, transceivers, hubs, print servers and much more. We produce these
products at our Gaithersburg, MD, USA, facility, and can custom manufacture
products for your unique needs.
We would like to hear from you. Please contact us in any of the fol-
lowing ways to tell us how you like this product and how we can meet your
product needs today and in the future.
Web:
(301) 975-1000
Sales E-mail:
Support E-mail:
Phone - Sales
Phone - Support (301) 975-1007
Fax:
(301) 869-9293
Mail:
Patton Electronics Company
7622 Rickenbacker Drive
Gaithersburg, MD 20879 USA
We are committed to a quality product at a quality price. Patton
Electronics is BABT and ISO 9001 certified. We meet and exceed the highest
standards in the industry (CE, UL, etc.).
Please contact us and let us know how we may provide you with the
answers to your needs.
Thank you.
Burton A.Patton
Executive Vice President
P.S. Please tell us where you purchased this product.
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
_________________________________________________________
13
Download from Www.Somanuals.com. All Manuals Search And Download.
|