| Doc #: 102001UA   Part #: 07M3060/V24-A   B DIGITAL BRIDGE   3060/V24   (CTS MD-V.24/TCB)   INSTALLATION AND OPERATIONS MANUAL   January 4, 2000   An ISO-9001   Certified Company   Copyright © 2000 Patton Electronics Co., All Rights Reserved.   Download from Www.Somanuals.com. All Manuals Search And Download.   INSTALLATION AND OPERATIONS MANUAL   PATTON ELECTRONICS CO.   3060/V24   102001UA   EMISSION REQUIREMENTS   FCC CLASS A   Warning: Changes or modifications to this unit not expressly approved by the party   responsible for compliance could void the user’s authority to operate the equipment.   NOTE: This equipment has been tested and found to comply with the limits for a Class A   digital device, pursuant to Part 15 of FCC rules. These limits are designed to provide   reasonable protection against harmful interference when the equipment is operated in a   commercial environment. This equipment generates, uses, and can radiate radio frequency   energy and, if not installed and used in accordance with the instruction manual, may cause   harmful interference to radio communications. Operation of this equipment in a residential   area is likely to cause harmful interference in which case the user will be required to correct   the interference at his own expence.   CANADIAN EMISSIONS   This digital apparatus does not exceed the Class A limits for noise emmissions from a   digital apparatus set out in the Radio Interference Regulations of the Canadian Department   of Communications.   Le present appareil numerique n’emet pas de bruits redioelectriques depassant les limites   applicables aux appareils numeriques de la Class A prescites dans le Reglement sur le   brouillage redioelectrique edicte par le ministere des Communications du Canada.   ii   Download from Www.Somanuals.com. All Manuals Search And Download.   PATTON ELECTRONICS CO.   3060/V24   INSTALLATION AND OPERATIONS MANUAL   102001UA   Contents   CHAPTER 1 - OPERATION   Channel Clocking............................................................................................................................... 1-1   Fallback Clocking............................................................................................................................... 1-1   Channel Interface .............................................................................................................................. 1-1   Anti-streaming.................................................................................................................................... 1-2   Channel Selection Modes ................................................................................................................. 1-3   Channel Tail Circuits ......................................................................................................................... 1-4   Interface Connections ....................................................................................................................... 1-4   Front Panel LEDs .............................................................................................................................. 1-4   Channel Enable / Disable Switches .................................................................................................. 1-4   Power Supply..................................................................................................................................... 1-4   CHAPTER 2 - SETUP AND INSTALLATION   Power Connection ............................................................................................................................. 2-1   Factory Configuration Switch Settings .............................................................................................. 2-1   Disassembly ...................................................................................................................................... 2-2   Installation.......................................................................................................................................... 2-2   Equipment Grounding (SW21-8)....................................................................................................... 2-2   RTS To CTS Delay (SW22-1,2,3) ..................................................................................................... 2-3   Anti-Streaming (SW21-1,2,3) ............................................................................................................ 2-3   Receive Data Mode (SW23-4) .......................................................................................................... 2-3   Control Turn-Off Delay in "DATA" Switching Mode (SW23-1,2) ...................................................... 2-4   Switch on Data / Control (SW25-1,2,3,4,5,6)....................................................................................2-4   Internal Baud Rates (SW22-4,5,6,7) ................................................................................................. 2-4   Fallback Clock Enable (SW-23-5) ..................................................................................................... 2-5   Fallback Clocking From Sub-Channel 6 (SW22-4,5,6)..................................................................... 2-5   Fallback Mode Selection (SW23-6)................................................................................................... 2-5   TX Clock Source Selection (SW21-4,5,6).........................................................................................2-5   TX Clock Pin Selection (SW21-7) ..................................................................................................... 2-5   RX Clock Source Selection (SW24-1,2,3) ........................................................................................ 2-6   Tail Circuit Buffers (SW22-8) ............................................................................................................ 2-6   Port DCE/DTE Selection (SW7 thru SW20) ..................................................................................... 2-6   Test Voltage Enable Pins 9 & 10 (JP4 & JP5) .................................................................................. 2-7   DTR / DSR Forced Active (JP6 thru JP12) ....................................................................................... 2-7   FACTORY Test Jumpers (JP1, JP2 and JP3) .................................................................................. 2-8   APPENDIX   Typical Application............................................................................................................................ A-1   Typical Tail Circuit Configuration ..................................................................................................... A-1   Interface Pins Supported .................................................................................................................. A-1   Master DTE / Sub-Channel DTE Interface Flow Diagram ............................................................... A-2   Master DTE / Sub-Channel DCE Interface Flow Diagram .............................................................. A-2   Master DCE / Sub-Channel DTE Interface Flow Diagram .............................................................. A-3   Master DCE / Sub-Channel DCE Interface Flow Diagram .............................................................. A-3   TECHNICAL SPECIFICATIONS ...................................................................................................... A-4   iii   Download from Www.Somanuals.com. All Manuals Search And Download.   PATTON ELECTRONICS CO.   3060/V24   INSTALLATION AND OPERATIONS MANUAL   102001UA   CHAPTER 1 - OPERATION   The Patton 3060/V24 (MD-V.24/TCB) is a network enhancement accessory intended for high   speed synchronous or asynchronous RS-232 modem, or port sharing applications. The 3060/   V24 (MD-V.24/TCB) allows for immediate expansion of a system without the requirement of   additional communication lines. The 3060/V24 (MD-V.24/TCB) allows any combination of up   to six RS-232 DCE or DTE devices to share a single RS-232 DCE or DTE high speed link in   a point-to-point or multi-point polled network.   Channel Clocking   The Patton 3060/V24 (MD-V.24/TCB) is protocol transparent and operates in synchronous   and asynchronous environments at data rates up to 76,800bps, depending on cable length   and attached equipment. Clocking can be derived from the Master Port clock, (pins 15 or 24   for TXC and 17 for RXC), the internal clock generator or any Sub-Channel clock, (pins 15 or   24 for TXC and 17 for RXC).   Fallback Clocking   In the event of loss of an externally provided clock or optionally Sub-Channel 1 DCD becoming   inactive, the 3060/V24 (MD-V.24/TCB) has the ability to automatically fall back to the   predetermined internal baud rate clock or the Sub-Channel 6 RX Clock (pin 17).   Channel Interface   The 3060/V24 (MD-V.24/TCB) has seven DB-25 female connectors located on the rear of the   unit. Each port is DCE/DTE selectable, which eliminates the need for crossover cables. DSR   or DTR can additionally be forced to the active state individually on each Sub-Channel by   Jumpercontrol.   OPERATION   1-1   Download from Www.Somanuals.com. All Manuals Search And Download.   PATTON ELECTRONICS CO.   3060/V24   INSTALLATION AND OPERATIONS MANUAL   102001UA   Anti-streaming   A typical problem often encountered is a “STREAMING” remote terminal. The streaming   problem can tie up an entire circuit until the offending device has recovered or is powered   down. A streaming condition occurs when a Sub-Channel remains active, disrupting the   polling sequence. The 3060/V24 (MD-V.24/TCB) provides two user selectable modes of   controlling a streaming condition, an automatic anti-streaming Abort Timer with eight   selectable block lengths and a setting to disable anti-streaming for large data block transfers,   and a manual Operator Control mode (front panel push button switch).   Automatic Anti-Streaming - Automatic Anti-streaming will block the asserted control signal   from the Sub-Channel Port, releasing the 3060/V24 (MD-V.24/TCB) to accept requests from   any other Sub-Channel that has not been locked out due to a streaming condition. When a   Sub-Channel is locked out for streaming, a visual indication, by Sub-Channel, is provided on   the front panel. The Sub-Channel will no longer receive data or CTS from the Master Port.   Any data sent to the Master Port by the streaming device will be lost. Once a Sub-Channel is   locked out due to streaming, the Sub-Channel will remain locked out until the attached device   removes the streaming condition. If RTS is held active, RTS must become inactive, if   continuous data transitions have triggered the Anti-Stream logic, the transitions must stop   before the 3060/V24 (MD-V.24/TCB) will clear the Anti-Stream logic to that Sub-Channel.   Removing the Sub-Channel via the front panel disable switch will not clear the Anti-stream   logic for a Sub-Channel once it has been activated.   Manual Anti-Stream - A streaming condition caused by one of the attached terminals can be   quickly corrected by the Patton 3060/V24 (MD-V.24/TCB) via the associated front panel   locking switches. A switch is provided for each Sub-Channel and permits the rapid removal of   a streaming terminal without having to disconnect any cables or power down the offending   terminal. Terminals may be selectively removed for self-test and maintenance without affecting   the remaining Sub-Channels. Once the streaming condition has been corrected, the front   panel switch is simply depressed to the locked (Enable) position (Green indicator ON) to re-   establish normal operation. Removing a Sub-Channel with the front panel switch will block   data from the Sub-Channel going to the Master Port but will not block data going from the   Master Port to the Sub-Channel as the Automatic Anti-Stream option did.   OPERATION   1-2   Download from Www.Somanuals.com. All Manuals Search And Download.   PATTON ELECTRONICS CO.   3060/V24   INSTALLATION AND OPERATIONS MANUAL   102001UA   Channel Selection Modes   The Patton 3060/V24 (MD-V.24/TCB) provides two selectable Sub-Channel service modes of   operation, the Scanning Mode and Priority Mode. Depending on system requirements, either   mode may be selected by internal DIP switch settings. Both modes switch on activity from the   Sub-Channel.   In the Scanning Mode the Patton 3060/V24 (MD-V.24/TCB) scans each Sub-Channel, in   sequence, beginning with Sub-Channel 1. This rotational sequence is repeated continually   with each attached Sub-Channel having equal access to the communications link. When data   or control lines from a Sub-Channel become active that Sub-Channel is switched through to   the master port by the 3060/V24 (MD-V.24/TCB). All remaining Sub-Channels are locked out   until the first device becomes inactive. When the Sub-Channel device becomes inactive, the   3060/V24 (MD-V.24/TCB) will resume scanning the Sub-Channels for another active signal.   When configured for Priority Mode operation, the Patton 3060/V24 (MD-V.24/TCB) monitors   all Sub-Channels simultaneously with Sub-Channel 1 having the highest priority. When a Sub-   Channel becomes inactive, the 3060/V24 (MD-V.24/TCB) will automatically default to the   highestpriority(lowestnumber)Sub-Channelwithactivity.   Contention for the Master port is accomplished by asserting RTS (Request to Send) if the   Sub-Port is configured as a DCE, DCD (Data Carrier Detect) if the Sub-Port is configured as   a DTE or Data Transitions from the attached Sub-Channel devices in either configuration. The   active interface lead, RTS or DCD, as well as selection of contention mode, “Data Transitions”   or “Interface Lead” activation, can be selected on an individual basis for each Sub-Channel.   Once a Sub-Channel asserts an active control signal the control signal will be passed through   to the Master Port, depending on DTE / DCE configuration of the Sub-Channel and Master   Port. This control will be passed without delays. If the Master Port is configured as a DTE the   signal will be passed as RTS. The CTS returned to the Master will have an optional delay   added before the signal is returned to the Sub-Channel port.   Port Enable / Disable, front panel switches must be pushed in (GREEN indication) for a Sub-   Channel to access the Master Port regardless of the mode of operation selected.   OPERATION   1-3   Download from Www.Somanuals.com. All Manuals Search And Download.   PATTON ELECTRONICS CO.   3060/V24   INSTALLATION AND OPERATIONS MANUAL   102001UA   Channel Tail Circuits   A buffer is built into the unit for tail circuit (DCE to DCE) applications. An 8 bit centered ring   buffer is used to correct the clock phasing errors generated between the Modem on the   Master Port and the Sub-Channel port for the data transferred from the Sub-Channel to the   Master Port. If the unit is operated in an asynchronous environment the buffer must be   bypassed. This is accomplished by moving the SYNC/ASYNC switch to ASYNC.   Interface Connections   All connections are made via industry standard EIA RS-232 DB-25 female connectors located   on the rear of the unit. The Following interface leads are implemented, Chassis (1), TXD (2),   RXD (3), RTS (4), CTS (5), DSR (6), Sig Gnd (7), DCD (8), Plus Unreg (9), Minus Unreg (10),   TXC (15), RXC (17), DTR (20), XTXC (24). Pins 9 & 10 can be disabled by Jumpers on the   PCB.   Front Panel LEDs   Front panel LEDs are provided to indicate power is applied, RXD and TXD activity from the   Master Port, Sub-Channel activity of each individual Port, Anti-Stream condition of each Sub-   Channel and an indication of clock Fallback condition.   Channel Enable / Disable Switches   Front panel switches allow operator intervention to remove an individual Sub-Channel from   accessing the Master Port. Positive latching type switches are provided for each Sub-   Channel port for isolating or removing a streaming terminal. The Sub-Channel is activated by   pushing the switch until it is in the “IN” position. The switch will indicate GREEN in color. To   disable a Sub-Channel push the switch until it locks in the “OUT” position, the switch will   indicate BLACK in color. Disabling a Sub-Channel with the front panel does not prevent the   Sub-Channel from receiving data from the Master Port only from sending data to the Master   Port.   Power Supply   A linear power supply is located internally, an external 110/220VA switch is located on the rear   of the unit. If chassis ground and signal ground need to be tied together this can also be   accomplished by switch selection. The unit is Rackmountable for 19" or 23" cabinets, by   ordering an optional Rackmount Kit. Safety approvals granted are UL, CSA and TÜV as well   as emission approval for FCC Class A.   OPERATION   1-4   Download from Www.Somanuals.com. All Manuals Search And Download.   PATTON ELECTRONICS CO.   3060/V24   INSTALLATION AND OPERATIONS MANUAL   102001UA   Caution, Disconnect the POWER Before Removing The Cover   Vorsicht, Befor Deckung Abnehmen Mach Strom Zu.   CHAPTER 2 - SETUP AND INSTALLATION   Power Connection   Before connecting the 3060/V24 (CTS MD-V.24/TCB) to a AC power source the top cover   must be installed and secured with the supplied #8-32 screws. The unit is supplied with a 110/   220VA voltage switch, turn the switch with a   110 / 220VA Switch   coin or screw driver to the appropriate   Fuse Drawer   voltage for your country. EXAMPLE: In the   W AR N IN G : F OR C O N TIN U E D PR O T EC TIO N   110   AG AINS T RISK O F FIRE, REPLAC E O N LY   W IT H S AM E TYP E A N D R AT IN G F USE.   United States of America; set to 110VA.   The unit is supplied with a IEC power   PORT   4 MASTER DTE/ DCE   connector next to the voltage select   switch, plug the power cord into the   connector until it is firmly seated. You   may now connect the power cord into   yourACoutlet.   IEC Power Connector   Factory Configuration Switch Settings   The 3060/V24 (CTS MD-V.24/TCB) is configured prior to shipment with the switches set to the   followingdefaultpositions:   Switch 21 - 1,2,3 and 8 to OFF, 4, 5, 6 and 7 to ON.   Anti-Stream timer = 2 M bits   TX Clock Source = Master pin 15   Chassis Ground not connected to Signal Ground   Switch 22 - 4 and 5 to OFF, 1, 2, 3, 6, 7 and 8 to ON.   CTS Delay = 0   Internal Baud Rate = 9600   Sync Mode   Switch 23 - 1, 2, 3 and 4 to OFF, 5 and 6 to ON.   No Data Time Out = 2048 bits   Anti-Stream = Disabled   Broadcast Data to Sub-Channels   Fallback Clock = Disabled   Fallback Clock Source = Data Transitions   SETUP & INSTALLATION   2-1   Download from Www.Somanuals.com. All Manuals Search And Download.   PATTON ELECTRONICS CO.   3060/V24   INSTALLATION AND OPERATIONS MANUAL   102001UA   Switch 24 - All to ON   RX Clock Source = Master   Contention Mode = Priority   Switch 25 - All to ON   Sub-ChannelActivityIndicatedbyInterfaceControl(RTS/DCD)   If the system application requires one or more of the default settings to be changed, it will be   necessary to remove the top cover of the enclosure to access and change the DIP switches   located on the printed circuit board.   Disassembly   Remove the top cover by removing the phillips head screws located on the left and right sides   of the 3060/V24 (CTS MD-V.24/TCB). DTE/DCE switches SW7 through SW20, interface   Jumpers J4 through J12 and configuration switches SW21 through SW25 are located on the   PCB as indicated on the strapping guide in the Appendix of this manual. After the switch   selection activity is completed, re-install the top cover BEFORE connecting to a AC   power source.   Installation   Select an appropriate location accessible to and within six feet of an AC power outlet, the   outlet must have a ground pin receptacle for product warranty. The DCE-to-DTE cabling   between each attached device and the 3060/V24 (CTS MD-V.24/TCB) should be “Straight   Through”, shielded and terminated with male connectors. Sub-Channels are marked PORT 1   through PORT 6, the Master Port is marked, MASTER DCE/DTE. If any terminal has a priority   service mode, ensure it is connected to the port connector designated "PORT 1" on the rear   panel of the 3060/V24 (CTS MD-V.24/TCB). Secure other terminals or Modems to be   serviced to the remaining “PORT” connectors. Connect the MODEM or TERMINAL to the   connector designated “MASTER DTE/DCE”.   Equipment Grounding (SW21-8)   Switch SW21-8 provides for grounding interconnection in those systems requiring a   connection between (Frame Ground) and (Signal Ground). Connect ONLY if required.   SETUP & INSTALLATION   2-2   Download from Www.Somanuals.com. All Manuals Search And Download.   PATTON ELECTRONICS CO.   3060/V24   INSTALLATION AND OPERATIONS MANUAL   102001UA   RTS To CTS Delay (SW22-1,2,3)   If a CTS delay is desired, set SW22-1, 2 and 3 to the required value as indicated below.   SW22-1 SW22-2 SW22-3   Time   No Delay   1mS   ON   OFF   ON   ON   ON   ON   ON   OFF   OFF   ON   ON   2mS   OFF   ON   ON   4mS   OFF   OFF   OFF   OFF   9mS   OFF   ON   ON   18mS   36mS   72mS   OFF   OFF   OFF   Anti-Streaming (SW21-1,2,3)   The maximum data block size is user selectable via switch SW21- 1, 2 and 3. As shown   below eight block sizes are provided to the user. To disable anti-streaming set SW23-3 to the   OFF position. The maximum block size is normally defined at the time of installation.   SW21-1 SW21-2 SW21-3 CLOCKS   ON   OFF   ON   ON   ON   ON   ON   1024   2048   4096   16 K   OFF   OFF   ON   ON   OFF   ON   ON   OFF   OFF   OFF   OFF   64 K   OFF   ON   ON   256 K   1 MEG   2 MEG   OFF   OFF   OFF   Receive Data Mode (SW23-4)   Setting switch SW23-4 to ON sets the 3060/V24 (CTS MD-V.24/TCB) into the Gated Mode.   Only the Sub-Channel that is currently active will receive the data from the master port. Setting   position 4 to OFF enables the Broadcast mode. Receive Data from the Master Port is sent to   allSub-Channels.   SETUP & INSTALLATION   2-3   Download from Www.Somanuals.com. All Manuals Search And Download.   PATTON ELECTRONICS CO.   3060/V24   INSTALLATION AND OPERATIONS MANUAL   102001UA   Control Turn-Off Delay in "DATA" Switching Mode (SW23-1,2)   When configured to switch on DATA, switch SW23-1 and 2 set the Sub-Channel release time   in clocks. The value selected is the number of clocks at the current baud rate that must occur   without any data transitions on the Sub-Channel to indicate that Sub-Channel has completed   its transmission and the 3060/V24 (CTS MD-V.24/TCB) can resume servicing the other Sub-   Channels. The following table should be used to set this time period.   SW23-1 SW23-2 CLOCKS   ON   ON   ON   OFF   ON   16   64   OFF   OFF   256   2048   OFF   Switch on Data / Control (SW25-1,2,3,4,5,6)   Each sub-channel is independently selectable for switch on data or switch on an active   interface control lead. Set SW25 pos 1 to OFF if sub-channel 1 switch on Data is required.   Set pos 1 to ON if switch on interface control lead is desired. Position 2 thru 6 are associated   withsub-channels2thru6.   Internal Baud Rates (SW22-4,5,6,7)   Switch SW22-4, 5, 6 and 7 select the master clock rate when Internal Clock Source is selected   on TX Clock Source or RX Clock Source. In addition the Fallback clock rate is also selected   with this option. When Fallback clocking is required, the RX Clock Source and TX Clock   Source should not be set to INTERNAL. Selecting CHAN 6 RXC allows Fallback clocks to   originate from Sub-Channel 6 pin 17. The following table shows the available rates. If CHAN   6 RXC is selected, SW22-7 can be in either position.   SW22-4 SW22-5 SW22-6 Pos 7=ON Pos 7=OFF   ON   OFF   ON   ON   ON   ON   ON   76,800   38,400   19,200   9,600   4,800   2,400   1,200   57,600   28,800   14,400   7,200   3,600   1,800   900   OFF   OFF   ON   ON   OFF   ON   ON   OFF   OFF   OFF   OFF   OFF   ON   ON   OFF   OFF   OFF   CHAN 6 RXC   SETUP & INSTALLATION   2-4   Download from Www.Somanuals.com. All Manuals Search And Download.   PATTON ELECTRONICS CO.   3060/V24   INSTALLATION AND OPERATIONS MANUAL   102001UA   Fallback Clock Enable (SW-23-5)   If Clock Fallback is required when the primary clock fails, set switch SW23-5 to OFF. If   Fallback is not required set SW23-5 to ON. The Fallback clock rate is selected with the   internal baud rate option. When the Fallback is activated the FBC LED will illuminate.   Fallback Clocking From Sub-Channel 6 (SW22-4,5,6)   To use the Sub-Channel 6 RX Clock as the Fallback clock set SW22-4, 5 and 6 to OFF. Any   other position will select some internal clock rate as called out in the Internal Clock Rate   selection section.   Fallback Mode Selection (SW23-6)   If Fallback is required, two modes are available via switch SW23-6. To Fallback when the   transitions from the primary clock source stop, set SW23-6 to ON. To Fallback when DCD on   Sub-Channel 1 becomes inactive, set SW23-6 to OFF.   NOTE: Both TX and RX Clock Source Select MUST Be Set !!!!   TX Clock Source Selection (SW21-4,5,6)   TX Clock Source is selected by switch SW21-4, 5 and 6. The following table indicates the   source options provided by the 3060/V24 (CTS MD-V.24/TCB). When using the unit in Async   Mode, the INTERNAL clock source must be selected.   SW21-4 SW21-5 SW21-6   Source   Master   Port 1   Port 2   Port 3   Port 4   Port 5   Port 6   Internal   ON   OFF   ON   ON   ON   ON   ON   OFF   OFF   ON   ON   OFF   ON   ON   OFF   OFF   OFF   OFF   OFF   ON   ON   OFF   OFF   OFF   TX Clock Pin Selection (SW21-7)   The primary transmit clock can be derived from either pin 15 or 24. If pin 15 is to be the   source for primary TX Clock, set SW21-7 to ON. If pin 24 is to be the source for primary TX &   RX Clock, set SW21-7 to OFF.   SETUP & INSTALLATION   2-5   Download from Www.Somanuals.com. All Manuals Search And Download.   PATTON ELECTRONICS CO.   3060/V24   INSTALLATION AND OPERATIONS MANUAL   102001UA   RX Clock Source Selection (SW24-1,2,3)   RX Clock Source is selected by SW24-1, 2 and 3. The following table indicates the source   options provided by the 3060/V24 (CTS MD-V.24/TCB). If the TXC source is pin 24, both   RXC and TXC will be sourced from pin 24. When the unit is used in an Async network select   INTERNAL as the source of the RX Clock.   SW24-1 SW24-2 SW24-3   Source   Master   Port 1   Port 2   Port 3   Port 4   Port 5   Port 6   Internal   ON   OFF   ON   ON   ON   ON   ON   OFF   OFF   ON   ON   OFF   ON   ON   OFF   OFF   OFF   OFF   OFF   ON   ON   OFF   OFF   OFF   Tail Circuit Buffers (SW22-8)   The 3060/V24 (CTS MD-V.24/TCB) has a Tail Circuit Buffer that is automatically selected   when a Sub-Channel is set as a DTE. The buffer will provide clock synchronization of the data   from the Sub-Channel to the Master Port for Tail Circuit operations. The buffer is de-activated   when the Sub-Channel is configured as a DCE. When operating in an asynchronous   environment the Buffer must be bypassed. To bypass the buffer in a synchronous or   asynchronous application, set switch SW22-8 to OFF (ASYNC). For normal operation in a   synchronous environment set SW22-8 to ON (SYNC). When using a tail circuit modem with   the 3060/V24 (CTS MD-V.24/TCB), the modem connected to the Sub-Channel, should be set   to External Transmit Clocking. The modem at the remote end of the connection should be set   to RX-TX Clocking or Slaved TX Clock. This will insure the same clock is present throughout   the network and clock slippage will not occur.   Port DCE/DTE Selection (SW7 thru SW20)   Slide switches SW7 through SW20 are used to configure DTE/DCE for each port. Slide Both   switches associated with a port to the same position. Example: If connecting a modem (DCE   Device) to the PORT, then the port should be configured as a DTE interface. Slide both   switches to the DTE position toward the interface connector. If connecting a terminal (DTE) to   the Sub-Channel, the port should be configured as a DCE. Slide both switched to the DCE   position away from the interface connector. The port is always configured opposite to the   interface that is to be connected to it. When a port is selected as a DCE, pin 9 and 10 test   voltages are provided to the interface connector if JP4 and JP5 are installed. If the port is   SETUP & INSTALLATION   2-6   Download from Www.Somanuals.com. All Manuals Search And Download.   PATTON ELECTRONICS CO.   3060/V24   INSTALLATION AND OPERATIONS MANUAL   102001UA   configured as a DTE, pins 9 and 10 are open. JP4 and JP5 control Plus Unreg and Minus   Unreg to all Sub-Channels, therefore it is not possible to have test power on one DCE without   having it on all DCE Sub-Channels.   Test Voltage Enable Pins 9 & 10 (JP4 & JP5)   Pin 9 and Pin 10 unregulated power is provided on each DB-25 connector configured as a   DCE if JP4 and JP5 are installed. Pin 9 and 10 unregulated power is not provided to any   connector configured as a DTE regardless of JP4 and JP5 installation.   DTR / DSR Forced Active (JP6 thru JP12)   DTR is tied to DSR on each of the Sub-Channel ports. If the device connected does not   supply a DTR but requires DSR (DTE) or does not supply DSR but requires DTR (DCE),   installing the forced DTR/DSR jumper (JP6-JP12) for the appropriate Sub-Channel will solve   this problem. The line is forced to +8V via an 820Ω resistor, providing isolation to any driver   that might be on the interface.   Channel Jumper Channel   Jumper   JP10   Master   JP6   JP7   JP8   JP9   4 5 6 1 2 3 JP11   JP12   SETUP & INSTALLATION   2-7   Download from Www.Somanuals.com. All Manuals Search And Download.   PATTON ELECTRONICS CO.   3060/V24   INSTALLATION AND OPERATIONS MANUAL   102001UA   FACTORY Test Jumpers (JP1, JP2 and JP3)   The three test jumpers JP1, 2 and 3, must be installed for the unit to properly function. These   jumpers are used in the manufacture and test of the product prior to shipment.   SETUP & INSTALLATION   2-8   Download from Www.Somanuals.com. All Manuals Search And Download.   PATTON ELECTRONICS CO.   3060/V24   INSTALLATION AND OPERATIONS MANUAL   102001UA   APPENDIX   RS-232   RS-232   Leased   Leased   or   or   Dial Line   Dial Line   RS-232 MODEM   RS-232 MODEM   RS-232   RS-232   Leased   or   Dial Line   RS-232 MODEM   3060/V24   Typical Application   Modem   Modem   External   Slave   Host   TX Clocking   TX Clocking   XTXC-24   Modem   Data   Data   Data   Data   TXC-15   Data   TXC-15 RXC-17   XTXC-24   RXC-17   RXC-17   Slave   XTXC-24   TX Clocking   Internal   RXC-17   Terminal   TXC-15   TX Clocking   Modem   Buffer   Data   Data   3060/V24   Typical Tail Circuit Configuration   DB-25 RS-232   Shield (common)   2 Transmit Data (from DTE)   1 14   15   16   17   18   19   20   21   22   23   24   25   Transmit Clock (from DCE)   Receive Clock (from DCE)   3 4 5 6 7 8 9 Receive Data (from DCE)   Request to Send (from DTE)   Clear To Send (from DCE)   Data Set Ready (from DCE)   Signal Ground (common)   Data Terminal Ready (from DTE)   External Transmit Clock (from DTE)   Data Carrier Detect (from DCE)   + Voltage   10 - Voltage   11   12   13   Interface Pins Supported   APPENDIX   A-1   Download from Www.Somanuals.com. All Manuals Search And Download.   PATTON ELECTRONICS CO.   3060/V24   INSTALLATION AND OPERATIONS MANUAL   102001UA   Master Port is a DTE   Channel Port is a DTE   Pin 3 RXD   Pin 2 TXD   Pin 4 RTS   Pin 5 CTS   Pin 6 DSR   Pin 8 DCD   Pin 2 TXD   Buffer   Pin 3 RXD   +8v   Clk Out   Clk In   Pin 4 RTS   Pin 5 CTS   Pin 6 DSR   Switch Control   Pin 8 DCD   Master TX Clock   Selection Logic   Pin 20 DTR   Pin 15 TXC   Pin 20 DTR   Pin 15 TXC   Pin 17 RXC   Pin 17 RXC   Master RX Clock   Selection Logic   Pin 24 ETXC   Pin 24 ETXC   Master DTE / Sub-Channel DTE Interface Flow Diagram   Master Port is a DTE   Channel Port is a DCE   Pin 3 RXD   Pin 2 TXD   Pin 4 RTS   Pin 5 CTS   Pin 6 DSR   Pin 8 DCD   Pin 20 DTR   Pin 3 RXD   Pin 2 TXD   Switch Control   Pin 4 RTS   Pin 5 CTS   Pin 6 DSR   Pin 8 DCD   Pin 20 DTR   Master TX Clock   Selection Logic   Pin 15 TXC   Pin 15 TXC   Pin 17 RXC   Pin 17 RXC   Master RX Clock   Selection Logic   Pin 24 ETXC   Pin 24 ETXC   Master DTE / Sub-Channel DCE Interface Flow Diagram   APPENDIX   A-2   Download from Www.Somanuals.com. All Manuals Search And Download.   PATTON ELECTRONICS CO.   3060/V24   INSTALLATION AND OPERATIONS MANUAL   102001UA   Master Port is a DCE   Pin 2 TXD   Channel Port is a DTE   Pin 2 TXD   Pin 3 RXD   Buffer   Pin 3 RXD   +8v   Clk Out   Clk In   Pin 4 RTS   Pin 4 RTS   Pin 5 CTS   Pin 6 DSR   Pin 8 DCD   Pin 20 DTR   Pin 5 CTS   Pin 6 DSR   Switch Control   +8v   Pin 8 DCD   Pin 20 DTR   Pin 15 TXC   Master TX Clock   Selection Logic   Pin 15 TXC   Pin 17 RXC   Pin 17 RXC   Master RX Clock   Selection Logic   Pin 24 ETXC   Pin 24 ETXC   Master DCE / Sub-Channel DTE Interface Flow Diagram   Master Port is a DCE   Channel Port is a DCE   Pin 2 TXD   Pin 3 RXD   Pin 3 RXD   Pin 2 TXD   Switch Control   Pin 4 RTS   Pin 5 CTS   Pin 4 RTS   Pin 5 CTS   Pin 6 DSR   Pin 8 DCD   Pin 6 DSR   +8v   Pin 8 DCD   +8v   Master TX Clock   Selection Logic   Pin 20 DTR   Pin 15 TXC   Pin 20 DTR   Pin 15 TXC   Pin 17 RXC   Pin 17 RXC   Master RX Clock   Selection Logic   Pin 24 ETXC   Pin 24 ETXC   Master DCE / Sub-Channel DCE Interface Flow Diagram   APPENDIX   A-3   Download from Www.Somanuals.com. All Manuals Search And Download.   PATTON ELECTRONICS CO.   3060/V24   INSTALLATION AND OPERATIONS MANUAL   102001UA   TECHNICAL SPECIFICATIONS   Applications   Sub-Channel Interface   Multiple RS-232 Sync or Async DCE or DTE   devices sharing one RS-232 DCE or DTE link   EIA RS-232 female connectors (DB-25)   Master Interface   Capacity   EIA RS-232 female connector (DB-25)   Front Panel   One to Six RS-232 Sync or Async DTE or DCE   devices One RS-232 DCE or DTE Master Channel   Data Format   Indicators: . Power, Send Data, Receive Data, Clock   Fallback, Sub-Channel Active, Sub-   Channel Stream   Data transparent at all data rates   Data Rates   Switches: .. Enable/Disable each Sub-Channel   Power Source   Up to 76,800bps   Timing   100-120/200-240 Vac, 50 to 60 Hz, 0.16/0.08 A,   Switch Selectable   Environmental   Internal:   Normal:   External:   DIP switch selectable   From Modem   Clock provided on any Sub-Channel   Operating Temp: .. 32° to 122°F (0° to 50°C)   Relative Humidity: 5 to 90% non-condensing   Altitude:................. 0 to 10,000 feet   Anti-streaming   Dimensions   Automatic:Selectable timeout intervals or disable   Height: .... 1.75 inches (4.44 cm)   Width: ..... 17.00 inches (43.18 cm)   Length: ... 11.00 inches (18.93 cm)   Terminal Service Modes   Scanning Mode: .. Channels are continuously   scanned for activity on a   Weight   sequential basis.   Priority Mode: ...... Channels are simultaniously   monitored channel one has   highest access   4.5 lbs (2.1 Kg)   APPENDIX   A-4   Download from Www.Somanuals.com. All Manuals Search And Download.   JP6 Thru JP12 Force DTR (20) / DSR(6) Active on the Master or Associated Port   Port 5   Master   Port 1   Port 4   Port 2   Port 3   Port 6   RX Clock Source SW24   1 2 3 Source   Master   SW 7   SW 8   SW 9   SW 10   SW 11   SW 12   SW 13   SW 14   SW 15   SW 16   O N   OFF   O N   O N   O N   OFF   O N   O N   O N   O N   OFF Port   OFF Port   Port   Port   Port   1 2 3 4 5 6 OFF OFF   O N   OFF   O N   O N   O N   OFF OFF Port   SW 17 SW 18 SW 19 SW 20   JP6   OFF OFF OFF Internal   JP9   JP8   JP7   JP10   JP11   JP12   Port 2   Port 1   Port 3   Master   TX Clock Source SW21   SW22   SW21   Port 4   Port 6   Port 5   4 5 6 Source   NOTE: Both TX & RX   Clk Source MUST   be Selected   O N   OFF   O N   O N   O N   OFF   O N   O N   O N   O N   OFF   OFF   Master   Anti-Stream Timer SW21   Port   Port   Port   Port   Port   Port   1 2 3 4 5 6 CTS Delay SW22   CTS Delay Time   1 2 3 Count   1024   2048   4096   16K   Anti-Stream Timer Select   O N   OFF   O N   O N   O N   OFF   O N   O N   O N   O N   1 2 3 Delay   OFF OFF   O N   OFF   O N   O N   O N   OFF   O N   O N   O N   O N   OFF   OFF   No Delay   O N   OFF   O N   O N   O N   OFF OFF   TX Clock Source   1 2 4 9 mS   mS   mS   mS   Internal Baud Rate Selection   OFF OFF   TXC Source Pin 15 = ON / Pin 24 = OFF   Chassis Gnd Connected to Signal Gnd= ON   O N   OFF   O N   O N   O N   OFF 64K   OFF 256K   OFF OFF   OFF OFF OFF   Internal   Sync   = ON   / Async   = OFF   O N   OFF   O N   O N   O N   OFF ON   OFF OFF   OFF OFF OFF   1 2 Meg   Meg   OFF ON   18 mS   36 mS   72 mS   JP5 JP4   OFF OFF   OFF OFF OFF   SW23   Minus Test Voltage   Enable / Disable   Plus Test Voltage   Enable / Disable   No Data Time Out Count   Anti-Stream Enable = ON / Disable = OFF   Data To Channels Gated = ON / Broadcast = OFF   Fallback Disable = ON / Enable = OFF   Internal Baud Rate SW22   No Data Time Out SW23   4 O N   OFF   O N   5 6 Pos 7=ON Pos 7=OFF   1 2 T O Count   O N   O N   OFF   O N   O N   O N   O N   OFF   OFF   76800   38400   19200   9600   4800   2400   57600   28800   14400   7200   3600   1800   900   Fallback Source, CLK Trans = ON / Chan 1 DCD = OFF   O N   O N   OFF   O N   OFF   O N   16   64   256   2048   OFF ON   SW25   JP3   JP2   JP1   OFF OFF   SW24   Channel 1   Channel 2   Channel 3   Channel 4   Channel 5   Channel 6   Factory Test Jumpers   Must Be INSTALLED   For Unit to OPERATE   OFF OFF   O N   OFF   O N   O N   O N   OFF OFF   Channel Activity Indicated By   Control = ON / Data = OFF   RX Clock Source   1200   Chan   6 RXC   OFF OFF OFF   Priority Mode = ON / Scan Mode = OFF   Not Used   Not Used   OFF ON   OFF ON   Sub-Channel Active   Anti-Stream   P W R TXD RXD   Clock Fall Back   1 2 3 4 5 6 1 2 3 4 5 6 Port Enabled = GREEN   Download from Www.Somanuals.com. All Manuals Search And Download.   B 7622 Rickenbacker Drive   Gaithersburg, MD 20879   Sales: 301 975-1000   Support: 301 975-1007   Download from Www.Somanuals.com. All Manuals Search And Download.   |