Panasonic Oxygen Equipment FV 05 11VKL1 User Manual

INSTALLATION INSTRUCTIONS  
Ventilating Fan  
Model No.  
FV-05-11VKSL1  
FV-05-11VKL1  
FV-11-15VKL1  
Contents  
Representative models:  
2-3  
GENERAL SAFETY INFORMATION  
PLEASE READ PRIOR TO INSTALLING THIS FAN  
DESCRIPTION  
3-4  
4
4
UNPACKING  
5
SUPPLIED ACCESSORIES  
5
DIMENSIONS  
5
WIRING DIAGRAM  
FEATURE  
6
FV-05-11VKSL1 FV-05-11VKL1  
INDICATION (PLUG ‘N PLAY FUNCTION DEVICES)  
MOTION (PLUG ‘N PLAY FUNCTION DEVICES)  
INSTALLATION (PLUG ‘N PLAY FUNCTION DEVICES)  
INSTALLATION (NEW CONSTRUCTION)  
INSTALLATION (RETROFIT)  
6-7  
7
8
8-10  
10  
MAINTENANCE  
MAINTENANCE  
(CLEANING)  
11  
(REPLACEMENT OF LAMP)  
11  
PRACTICAL GUIDE TO INSTALLATION  
SPECIFICATIONS  
BACK COVER  
BACK COVER  
BACK COVER  
PRODUCT SERVICE  
FV-11-15VKL1  
READ AND SAVE THESE INSTRUCTIONS  
Thank you for purchasing this Panasonic product.  
Please read these instructions carefully before attempting to install, operate or service  
the Panasonic product. Failure to comply with instructions could result in personal injury  
or property damage. Please explain to users how to operate and maintain the product  
after installation, and this booklet should be presented to users.  
Please retain this booklet for future reference.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GENERAL SAFETY INFORMATION CONTINUED  
WARNING  
When this product is no longer being operated, please remove the product to prevent the  
possibility of falling.  
Ceiling joist must be subjected to static load more than five times the weight of the product.  
Do not install with a method which is not approved in the instructions.  
Do not use this fan with any solid-state speed control device. Solid state controls may cause  
harmonic distortion which can cause motor humming noise.  
This product must be properly grounded.  
CAUTION  
Do not install this ventilating fan where interior room temperature may  
exceed 104°F(40°C).  
Prohibited  
Make sure that the electric service supply voltage is AC 120V, 60Hz.  
Follow all local electrical and safety codes, as well as the National  
Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA).  
Prohibited  
Always disconnect the power source before working on or near the fan,  
motor, light fixture or junction box.  
Protect the supply wiring from sharp edges, oil, grease, hot surfaces,  
Prohibited  
chemicals or other objects.  
Adaptor  
Do not kink the supply wiring.  
Prohibited  
Provide make up air for proper ventilation.  
For general ventilating use only. Do not use to exhaust hazardous or  
explosive materials and vapors.  
(Cooking area)  
Do not install above or  
inside this area  
Do not install the unit where ducts are configured as shown  
in Fig.A.  
Not for use in cooking area. (Fig.B)  
Floor  
Cooking  
equipment  
The special-purpose or dedicated parts, such as mounting  
fixtures, must be used if such parts are provided.  
Fig. B  
PLEASE READ PRIOR TO INSTALLING THIS FAN  
Spot and Continuous Ventilation: These fans are designed to run continuously ensuring a healthy  
environment at low CFM levels 24 hours a day. By utilizing the optional CustomVent Multi-Speed module  
the fans are built to run continuously at a pre-set lower level (FV-05-11VKSL1 and FV-05-11VKL1: 0, 30,  
40, 50, 60, 70, 80, 90, 100 CFM; FV-11-15VKL1: 0, 50, 60, 70, 80, 90, 100, 110, 120 CFM). The setting is  
dependent on the size of the house and the individual wishes of the homeowner. It is crucial that the  
installer pre-set the lower setting during the installation. Please refer to the chart below and the  
switch indication on page 6.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
PLEASE READ PRIOR TO INSTALLING THIS FAN CONTINUED  
CustomVent Multi-Speed module (Lower Setting). ASHRAE 62.2-2010  
(sq.feet)  
Two Bedrooms Three Bedrooms Four Bedrooms Five Bedrooms  
33  
38  
43  
48  
53  
58  
63  
68  
73  
78  
83  
88  
93  
40  
45  
50  
55  
60  
65  
70  
75  
80  
85  
90  
95  
100  
<1,000  
1,500  
2,000  
2,500  
3,000  
3,500  
4,000  
4,500  
5,000  
5,500  
6,000  
6,500  
7,000  
48  
53  
58  
63  
68  
73  
78  
83  
88  
93  
98  
103  
108  
55  
60  
65  
70  
75  
80  
85  
90  
95  
100  
105  
110  
These fans are also built to take care of the homeowner’s spot ventilation needs when the room is  
occupied. The basic fan models allow a choice of three speeds. When fans are equipped with the optional  
Multi-Speed module, these models kick up to a maximum level of 150 CFM for the FV-11-15VKL1 and 110  
CFM for the FV-05-11VKSL1 and FV-05-11VKL1 either when the switch is turned on or activated by the  
optional Condensation Sensor module or the optional Motion Sensor module.  
A High/Low Delay Timer, located inside the fan unit, is utilized to return the fan back to the pre-set  
Continuous ventilation mode. The installer needs to consult with the homeowner for the desired  
setting on the timer (0 - 60 minutes) and make the adjustments during the installation.  
DESCRIPTION  
These products are listed by UL under UL file No. E78414.  
These products use a sirocco fan driven by a DC motor powered by an integral transformer. The motor is  
designed to have long operating life, high dynamic response, higher speed ranges with saving energy.  
The grille covering the fan body is a spring-loaded, quick remove type. A damper for preventing air counter  
flow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level.  
The lighting unit is an energy-saving LED lighting device that uses two 7W LED lamps and produces almost  
the same illumination as a standard 60W incandescent lamp.  
FCC Note: This equipment has been tested and found to comply with the limits for a Class B digital device,  
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against  
harmful interference in a residential installation. This equipment generates, uses and can radiate radio  
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful  
interference to radio communications. However, there is no guarantee that interference will not occur in  
a particular installation. If this equipment does cause harmful interference to radio or television reception,  
which can be determined by turning this product on and off, the user is encouraged to try to correct the  
interference by one of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect equipment into outlet on a circuit different from that to which the receiver is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
Warning: This equipment must be installed by qualified person in accordance with the provided installation  
instructions; and all applicable codes and standards. Also, any changes or modifications not expressly  
approved by the party responsible for compliance could void the user’s authority to operate this equipment.  
DoC Responsible Party:  
Panasonic Corporation of North America  
Two Riverfront Plaza, Newark, NJ 07102  
1-866-292-7299  
Customer Call Support:  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:  
(1) This device may not cause harmful interference, and (2) this device must accept any interference  
received, including interference that may cause undesired operation.  
Risk of Fire: Type IC-Inherently Protected, Only Use LED Lamp, Max 7W, Type GU24.  
UNPACKING  
Unpack and carefully remove the unit from carton.  
Refer to the Supplied Accessories list to verify that all parts are present.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SUPPLIED ACCESSORIES  
Part name  
Part name  
Appearance  
Quantity  
Appearance  
Quantity  
2
Installation  
instructions  
Grille  
1
Warranty  
sheet  
1
4
4
Flex-Z FastTM  
bracket  
1
2
Tapping screw  
(ST4.2X20)  
7W  
LED lamp  
Self-drilling  
screw  
DIMENSIONS  
Unit: inches (mm)  
FV-11-15VKL1  
1 1/2 (38)  
1 (26)  
4
5/8 (116)  
13  
FV-05-11VKL1  
FV-11-15VKL1  
6
3/8 (163)  
7
3/8 (190)  
15  
14  
14  
FV-11-15VKL1  
FV-05-11VKSL1  
No.  
1
No.  
8
Part name  
Part name  
Connector cover  
Base PCB box  
Pick-A-Flow switch  
Lighting unit  
LED lamp  
Blade  
Grille  
Lens  
13 (330)  
2
3
9
10  
11  
12  
13  
14  
Motion sensor location  
(FV-MSVK1 not included)  
4
5
6
Junction box  
Adaptor  
Fan body  
Damper  
Multi-Speed module  
3 7/8 (100)  
7
(FV-05-11VKSL1 only,  
15  
Flex-Z FastTM bracket  
10 1/4 (260)  
3 7/8 (100)  
other models not included)  
WIRING DIAGRAM  
Junction box  
Fan body  
Switch for power  
(114°C Fuse)  
Live (Fan)  
Neutral  
Black  
DC-Motor  
(Power supply)  
AC120V 60Hz  
Thermally  
protected  
White  
Multi-Speed module  
(FV-05-11VKSL1  
only, other models  
not included)  
Hi/Low switch: When plug in  
Multi-Speed module;  
On/Off switch: When plug in  
other Plug ‘N Play modules.  
Red  
Red  
Plug ‘N Play module slot  
(Non-powered control wires)  
Plug ‘N Play module slot  
Green  
Earth ground  
Green  
Switch for power  
LED  
lamp  
Live (Light)  
Neutral  
Black  
(Power supply)  
AC120V 60Hz  
White  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
FEATURE  
[For models of: FV-05-11VKSL1, FV-05-11VKL1, FV-11-15VKL1.]  
The WhisperGreen Select Line of ventilation fans employs innovative, state-of-the-art technologies that  
provide a number of customizable unique features that lead to improved indoor air quality. Please  
read the installation manual first in order to realize the benefits of this customizable, modular fan.  
Optimum Ventilation Performance:  
Duct length, elbows and other factors increase static pressure which can hinder the performance of most  
ventilation fans. This fan utilizes SmartFlow microchip technology that monitors the static pressure in the  
system and speeds up or slows down the rpm of the fan depending upon the amount of resistance within  
the ducts. This feature allows the fan to perform as rated and avoid potential installation issues.  
Outstanding Energy Savings:  
The WhisperGreen Select Line of fans are built using DC motor technology. The DC motor is 30% - 70%  
more energy efficient than the minimum ENERGY STAR requirements.  
Pick-A-Flow Feature  
All the WhisperGreen Select base models of fans come with Pick-A-Flow  
speed options. The Pick-A-Flow switch on the face of all WhisperGreen  
Select fans allows the option to choose 50 – 80 – 110 CFM for the  
FV-05-11VKL1, FV-05-11VKSL1 or 110 – 130 – 150 CFM for the  
FV-11-15VKL1. These fans can run continuously or intermittently,  
depending upon the needs of the owner.  
Air volume type (CFM)  
Factory setting  
(
)
AIR VOLUME CFM  
05-11 50  
Pick-A-Flow  
switch  
80 110  
FV-05-11VKSL1  
FV-05-11VKL1  
MODEL  
50  
80  
110  
80 CFM  
11-15  
FV-11-15VKL1 110 130 150  
130 CFM  
MODEL110130150  
INDICATION (PLUG ‘N PLAY FUNCTION DEVICES)  
PLUG ‘N PLAY Modular Component Accessories  
Sold Separately, Not Included With Base Model Fan  
FV-VS15VK1 Multi-Speed module allows the fan to run continuously  
at lower speeds to maintain ventilation standards to meet Indoor  
Air Quality and then boost up to high speed to meet intermittent  
needs for ‘Spot’ or ‘Point Source’ exhaust needs. The FV-VS15VK1  
Modular Component will operate for both the FV-05-11VKL1 and the  
FV-11-15VKL1 matching the appropriate Multi-Speed setting shown  
below. The FV-05-11VKSL1 comes with the FV-VS15VK1 Multi-Speed  
module. It is not necessary to purchase this component.  
Note the options on the face of the FV-VS15VK1 Multi-Speed module  
to choose appropriate levels of airflow (CFM) and time delay before  
returning back to low speed (TIME). Choosing the Pick-A-Flow setting  
automatically adjusts the Multi-Speed setting accordingly. As an  
example, if the Pick-A-Flow Multi-speed setting is 80 CFM, the  
Multi-Speed settings adjust automatically to be 0, 30, 40, 50, 60 or 70  
CFM at the lower speeds. The fan will ‘boost’ to the 80 CFM speed as  
the high speed setting. Selecting a particular TIME option will cause  
the fan to run for the selected amount of time before returning to  
the lower speed setting chosen on the CFM dial.  
Note that there is ONLY ONE  
Plug ‘N Play slot to insert the  
Multi-Speed module within the  
base model fan. There are TWO  
interchangeable Plug ‘N Play  
slots to insert the Condensation  
Sensor module, Motion Sensor  
module or Nite-GloTM LED Night  
Light module within the base  
model fan.  
Multi-Speed Air volume (CFM)  
Pick-A-Flow (CFM)  
50  
80  
110  
110  
130  
150  
0
0
0
0
0
0
30  
30  
30  
50  
50  
50  
40  
40  
40  
60  
60  
60  
40  
50  
50  
70  
70  
70  
40  
60  
60  
80  
80  
80  
40  
70  
70  
40  
70  
80  
40  
70  
90 100  
40  
70  
FV-05-11VKSL1,  
FV-05-11VKL1  
(plug-in FV-VS15VK1)  
90 100 100 100  
90 100 110 110  
90 100 110 120  
FV-11-15VKL1  
(plug-in FV-VS15VK1)  
Delay Time (min)  
45  
Factory setting: 20 minutes.  
Delay Time position “0“ : Manual wall switch control is 0 minute;  
without manual wall switch control is 0.5 minute.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
INDICATION (PLUG ‘N PLAY FUNCTION DEVICES) CONTINUED  
PLUG ‘N PLAY Modular Component Accessories  
Sold Separately, Not Included With Base Model Fan  
FV-CSVK1 Condensation Sensor module turns the base fan on or  
boosts to higher speed when humidity is detected when used in  
combination with the FV-VS15VK1. The Condensation Sensor works  
based on calculations from the Psychrometric Chart, or combination  
of Relative Humidity (RH) and Temperature. This allows the fan to  
anticipate the formation of condensation and automatically turn on  
when needed to expel humid air. The Condensation Sensor is pre-set  
to run for 20 minutes; it will then check the RH and Temperature to  
detect if the fan needs to run for another 20 minutes cycle.  
FV-MSVK1 Motion Sensor module turns the base fan on or boosts  
to higher speed when motion is detected when using in combination  
with the FV-VS15VK1. The Motion Sensor is pre-set to run for 20  
minutes; it will then re-check for movement; if detected the fan will  
run for another 20 minutes cycle. The Motion Sensor detects within  
the range shown below.  
The distance that motion  
can be detected is limited  
to 10 feet (3m). The field  
of view of the sensor is 90°.  
(Room temperature is 25 C).  
FV-NLVK1 Nite-GloTM LED Night Light module automatically turns on  
when ambient light levels are met. Turning the dial on the Modular  
Nite-Glo Component to ‘DARK’ is ideal if the fan is in an isolated room  
with little ambient light from nearby rooms. Turning the dial to  
‘BRIGHT’ is ideal if there is light spill from nearby rooms. (Note that it is  
necessary to connect wall switch when only plug in FV-NLVK1, fan can  
operate on high speed with wall switch control, fan can also operate  
on low speed when used in combination with the FV-VS15VK1.)  
MOTION (PLUG ‘N PLAY FUNCTION DEVICES)  
PLUG ‘N PLAY Modular  
Components used in  
Combinations  
PLUG ‘N PLAY Modular Component Accessories  
Sold Separately, Not Included With Base Model Fan  
FV-CSVK1 + FV-MSVK1  
Turns the fan on for 20 minutes when either  
motion or excess humidity is detected.  
FV-CSVK1 + FV-VS15VK1  
Cycles the fan to high speed from low speed  
for the amount of time selected on the Control  
Dial based upon detection of excess humidity.  
FV-MSVK1 + FV-VS15VK1  
Cycles the fan to high speed from low speed  
for the amount of time selected on the Control  
Dial based upon motion within the room.  
Fan  
Time delay  
operation  
Motion  
Human  
active  
operation  
FV-CSVK1 only  
Fan  
ON/OFF  
20 minutes  
time delay  
When motion or  
excess humidity is  
detected, fan runs the delay time has  
at high speed. passed.  
Remains running  
at high speed until  
FV-MSVK1 only  
Fan  
active  
At low  
speed  
Depend on  
FV-VS15VK1 Time  
delay setting  
FV-CSVK1 + FV-VS15VK1  
FV-MSVK1 + FV-VS15VK1  
Fan  
Hi/Low speed  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION (PLUG ‘N PLAY FUNCTION DEVICES)  
You can purchase the specified Plug ‘N Play devices that are explained on page 6-7 and install them in positions  
2
3
,
and  
. Position  
can only be used with Multi-Speed module (model FV-05-11VKSL1 already have  
and can be used for any of the other optional control modules.  
this control installed), position  
2
3
1. Remove the connector cover from position  
, 2 or 3 .  
2. Plug in the specified devices to Base PCB box and fix to the slot, till hear the sound installed in place.  
Connector  
cover  
Base PCB box  
Slot  
2
2
3
3
Clasp  
Squeeze tabs on the Clasp to  
remove. Squeeze, insert and  
release the tabs on Clasp to replace.  
INSTALLATION (NEW CONSTRUCTION)  
The fan position between joists from 16" to 24"  
on center can be adjusted flexibly.  
Adaptor  
Machine screw  
(M4X6)  
CAUTION  
Please wear gloves during the installation  
work as follow.  
Fig.1  
Fan body  
1. Disconnet plug connector from receptacle and  
remove adaptor from fan body by removing the  
machine screw (M4X6) before installation. (Fig.1)  
Joist  
IMPORTANT:  
Remove the tape from damper and adaptor  
before installation. As shown below:  
Bend down  
4 tabs  
Adaptor  
Damper  
2 Tapping screws  
(ST4.2X20)  
Fig.2  
Tape  
Joist  
2. Bend down 4 tabs for positioning, install the  
Flex-Z FastTM bracket to joists by using 2 tapping  
screws (ST4.2X20) (Please prepare the screws and  
put on Flex-Z FastTM bracket before Flex-Z FastTM  
bracket is installed on joist). (Fig.2)  
3. Adjust the length of Flex-Z FastTM bracket as the  
spacing between joists, and install to joists by  
using 2 tapping screws (ST4.2X20). (Fig.3)  
4. Remove junction box cover and secure conduit  
or stress relief to junction box knock-out hole.  
(Fig.4)  
2 Tapping screws  
(ST4.2X20)  
Fig.3  
Circular duct  
Mastic or  
approved  
foil tape  
Conduit  
5. Install a circular duct and secure it with clamps,  
or ties and seal it with mastic or approved foil tape.  
4 inch 6 inch circular duct is needed to connect to  
relevant part of common adaptor. (Fig.4)  
6. Install the adaptor to Flex-Z FastTM bracket by  
using 2 self-drilling screws. (Fig.4)  
Knock-out  
hole  
Junction box  
cover  
2 Self-drilling screws  
Fig.4  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION (NEW CONSTRUCTION) CONTINUED  
7. Refer to wiring diagram on page 5.  
Follow all the local electrical safety codes as well  
as the National Electrical Code (NEC).  
FV-05-11VKSL1  
FV-05-11VKL1  
FV-11-15VKL1  
Conduit  
Earth ground to green  
Wire nut  
Using UL approved wire nuts, connect house  
power wires to ventilating fan wires. (Fig.5)  
Junction  
box  
Live to black  
(Fan)  
Netural to  
white  
Netural to white  
CAUTION  
Two red wires (Connect  
to a general manual  
Live to black  
(Light)  
Mount junction box cover carefully so that  
lead wires are not pinched.  
wall switch)  
Fig.5  
8. Insert fan body and slide into adaptor assy with some  
strength, untill the flange overlaps the Flex-Z FastTM  
bracket. Secure the fan body to Flex-Z FastTM bracket  
by using 2 self-drilling screws, plug connector to  
receptacle and secure the fan body to adaptor by  
using machine screw (M4X6). (Fig.6)  
Joist  
CAUTION  
Plug connector  
Receptacle  
Machine  
Secure machine screw (M4X6) to the suitable  
hole and not touch the Flex-Z FastTM bracket.  
Please fix the screw carefully to avoid screw  
slip teeth.  
screw  
(M4X6)  
2 Self-drilling  
screws  
Fig.6  
9. Finish ceiling work. Ceiling hole should be aligned  
with the inside edge of the flange. (Fig.7)  
Ceiling  
Unit: inches (mm)  
10. Remove the tapes from louver and springs before  
installation. Remove screw (M4X8) and light cover.  
(Fig.8)  
IMPORTANT:  
Replace the sensor cover before the installation  
(only for plug-in Motion sensor module FV-MSVK1).  
As shown below:  
After finishing the ceiling job, fill gap between flange  
and ceillng with caulk or other sealant to prevent air  
leakage  
Keep on pressing the clasps when removing the ornamental cover.  
Gloves  
Fig.7  
Remove screw  
(M4X8)  
Tapes  
Ornamental  
cover  
Fig.8  
Fig.9  
Light cover  
Insert the sensor cover (attachment for FV-MSVK1) into slot.  
Sensor  
cover  
LED lamp  
Secure  
screw  
(M4X8)  
11. Install the LED lamps. (Fig.9)  
12. Install light cover. (Fig.10)  
13. Insert the grille mounting spring on the wiring side  
into the slot and insert the plug connector into the  
housing of the lighting unit. (Fig.11 of page 10)  
Fig.10  
Light cover  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION (NEW CONSTRUCTION) CONTINUED  
Ceiling  
Mounting spring  
Plug  
CAUTION  
Motion sensor  
connector  
(FV-MSVK1 only)  
Before turn on the light, make sure the  
connector at the correct position. If not,  
Clasp  
Gloves  
Lighting  
unit  
the lighting can’t work.  
The claw of connector must latch the rib  
completely.  
LED night light  
(FV-NLVK1 only)  
Rib  
Inser plug  
connector  
14. Plug in the specified devices as your choice  
(refer to installation on page 8). Insert the  
motion sensor (FV-MSVK1 only) or LED night  
light (FV-NLVK1 only) into slot of the grille.  
Fix the lead wire into the clasp (Fig.11).  
Fig.11  
Claw  
Ceiling  
Grille  
15. Adjust Pick-A-Flow switch; if used, adjust the  
FV-VS15VK1 Multi-Speed module. (Fig.12)  
Refer to indication on page 6.  
16. Insert the other mounting spring into the slot  
as shown and mount grille to fan body. (Fig.13)  
Fig.12  
Ceiling  
Mounting spring  
CAUTION  
Gloves  
Mount grille carefully so that lead wire of  
lighting unit is not pinched.  
Grille  
Fig.13  
INSTALLATION (RETROFIT)  
Unit: inches (mm)  
Joist  
Conduit  
Circular duct  
WARNING  
Disconnect power source before working  
on unit.  
4 Tapping  
screws (ST4.2x20)  
1. Remove the existing fan and cut ceiling openning.  
Secure the Flex-Z FastTM bracket to joists by using 4  
tapping screws (ST4.2x20) (Please prepare the  
screws and put on Flex-Z FastTM bracket before  
Flex-Z FastTM bracket is installed on joist).  
(275)  
10 7/8  
Fig.14  
Ceiling (already existed)  
Conduit  
Circular duct  
Existing ductwork and wiring left in place. (Fig.14)  
Mastic or  
approved  
foil tape  
2. Follow the step 1, 4, 5 on page 8 and step 7 on  
page 9. (Before connect the circular duct to the  
adaptor, should pull down the circular duct from  
the ceiling)  
3. Install the adaptor to Flex-Z FastTM bracket by using  
2 self-drilling screws. (Fig.15)  
Joist  
Knock-out  
hole  
Junction box  
cover  
2 Self-drilling screws  
4. Secure the fan body to Flex-Z FastTM bracket by  
using 2 self-drilling screws, plug connector to  
receptacle and secure the fan body to adaptor  
by using machine screw (M4X6). (Fig.16)  
Ceiling  
Joist  
Fig.15  
CAUTION  
Secure machine screw (M4X6) to the suitable  
hole and not touch the Flex-Z FastTM bracket.  
Please fix the screw carefully to avoid screw  
slip teeth.  
Ceiling  
Flange  
Machine screw (M4X6)  
2 Self-drilling screws (Fix the  
5. Follow the step 10 to 16 on page 9 to 10.  
Fig.16  
TM  
flange and Flex-Z Fast bracket through the ceiling)  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE (CLEANING)  
WARNING  
Gloves  
Disconnect power source before working on unit.  
Fig.17  
CAUTION  
Ceiling  
Routine maintenance must be done every year.  
Please wear gloves during the cleaning work.  
Never use gasoline, benzene, thinner or any other  
such chemicals for cleaning the ventilating fan.  
Vacuum  
cleaner  
Do not immerse motor in water when cleaning.  
Do not soak resin parts in water over 140 F (60 C).  
Fig.18  
1. Clean grille. (Don’t put into hot water. Use non-abrasive  
kitchen detergent, wipe dry with clean cloth) (Fig.17)  
2. The grille should be dry after cleaning.  
3. Remove dust and dirt from fan body using a vacuum  
cleaner. (Fig.18)  
Ceiling  
4. Using a cloth dampened with kitchen detergent, remove  
any dirt from fan body. Wipe dry with clean cloth. (Fig.19)  
5. Reinstall grille.  
Gloves  
Fig.19  
MAINTENANCE  
(REPLACEMENT OF LAMP)  
Mounting spring  
Ceiling  
WARNING  
Motion sensor  
Plug  
(FV-MSVK1 only)  
connector  
Disconnect power source before working on unit.  
Clasp  
The lamp’s glass is fragile, be careful when the lamp  
Gloves  
is replaced.  
Make sure the temperature of lens and lighting  
unit has cooled down before maintenance  
(cleaning) or replacement of lamp.  
LED night light  
(FV-NLVK1 only)  
Remove  
Grille  
CAUTION  
Rib  
Claw  
Lighting  
unit  
plug  
connector  
Fig.20  
Remove dust and dirt from light cover and lens,  
before replace the lamps.  
The LED lamps should be replaced as the specified  
type. The supplied LED lamps are not intended for  
other use.  
Remove screw  
(M4X8)  
1. Remove grille by pulling down one mounting spring  
(Fig.20). Remove plug connector then pull down the other.  
(For models plug-in FV-MSVK1 or FV-NLVK1: Pull down the  
mounting spring that without lead wire passed side, and  
remove motion sensor or LED night light as shown in Fig.20)  
(Squeeze mounting spring and pull down carefully)  
Light cover  
Fig.21  
Fig.22  
2. Remove the screw as shown in step  
Remove the light cover as shown in step  
of Fig.21.  
of Fig.21.  
Lens  
3. Replace the LED lamps (CX-GU24-H-B, 7W) as shown in  
step 1 and step 2 of Fig.22.  
4. Install the LED lamps (CX-GU24-H-B, 7W) as shown in  
step 1 and step 2 of Fig.9 (Page 9).  
LED lamp  
5. Install light cover. (Fig.10 of page 9)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRACTICAL GUIDE TO INSTALLATION  
Properly insulate the area around the fan to 4 inches or 6 inches roof jack, wall cap,  
or soffit vent with backdraft damper  
minimize building heat loss and gain. (Fig.23)  
Loose fill or batt insulation can be placed  
directly over the fan housing in the attic.  
Mechanically connect duct to termination  
and seal with mastic or approved foil  
faced tape  
Our fans and fan/light combination units do  
2-3 ft straight run before elbow  
not create excessive heat that is a common  
In attic installation,  
problem with recessed light fixtures or some  
caulk box to drywall  
competitor’s fan/light combination. Our  
efficient, cool-running motors and our LED  
lighting unit do not create enough ambient  
heat to be subjected to these limitations.  
Short piece of flexible duct helps  
alignment and absorbs sound.  
Clamps plus mastic or approved  
foil faced tape at all flex joints  
Insulation  
Foil tape tightly covers all metal  
duct joints (glue PVC joints)  
3
SPECIFICATIONS  
Specifications for Base Model fans  
Duct  
Air volume  
Power (W)  
Lighting  
Air  
direction  
Voltage Frequency  
Noise  
(sones)  
Speed  
(rpm)  
Weight  
lb.  
diameter at 0.1"WG  
(inches)  
Model No.  
(V)  
(Hz)  
Fan  
(CFM)  
unit  
<0.3  
<0.3  
0.4  
<0.3  
<0.3  
0.6  
50  
80  
110  
110  
130  
150  
750  
825  
965  
650  
680  
730  
3.6  
6.0  
11.0  
8.5  
12.0  
16.5  
FV-05-11VKSL1  
FV-05-11VKL1  
Exhaust  
Exhaust  
4 or 6  
11.5(5.2)  
11.7(5.3)  
14  
14  
FV-11-15VKL1  
HVI Certified performance based on HVI Procedures 915, 916, and 920.  
Specifications for Multi Speed fans  
Duct  
Air volume  
Power (W)  
Air  
direction  
Voltage Frequency  
(V) (Hz)  
Noise  
(sones)  
Speed  
(rpm)  
Weight  
lb.  
diameter at 0.1"WG  
(inches)  
Model No.  
Lighting  
unit  
Fan  
(CFM)  
100  
90  
80  
70  
60  
50  
40  
30  
0
120  
110  
100  
90  
80  
70  
<0.3  
<0.3  
<0.3  
<0.3  
<0.3  
<0.3  
<0.3  
<0.3  
8.7  
7.0  
6.0  
4.7  
3.9  
3.6  
2.8  
2.5  
915  
865  
825  
795  
770  
750  
FV-05-11VKSL1,  
FV-05-11VKL1  
(Plug-in  
FV-VS15VK1)  
11.5(5.2)  
11.7(5.3)  
Exhaust  
Exhaust  
14  
14  
730  
725  
<0.3  
<0.3  
<0.3  
<0.3  
<0.3  
<0.3  
<0.3  
<0.3  
9.5  
8.5  
6.9  
5.7  
5.0  
4.3  
4.0  
3.2  
665  
650  
645  
640  
635  
630  
FV-11-15VKL1  
(Plug-in  
FV-VS15VK1)  
60  
50  
625  
620  
0
Reference performance based on HVI Procedures 915, 916, and 920. [( ) Standby wattage.]  
*
PRODUCT SERVICE  
Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only.  
Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit  
require service or parts, call Panasonic Call Center at 1-866-292-7299 (USA) or 1-800-669-5165 (Canada).  
Panasonic Corporation of North America  
Two Riverfront Plaza, Newark, NJ 07102  
Panasonic Canada lnc.  
5770 Ambler Drive, Mississauga, Ontario L4W 2T3  
Panasonic corporation 2014  
Printed in China  
X0114-2024 11KSL1420B  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miller Electric Welding System 185 DX User Manual
MTD Snow Blower K Style User Manual
Nady Systems Microphone UHF 10 User Manual
NewAir Electric Heater AH 450 User Manual
Nexstar Computer Drive CB SATAU3 User Manual
Olivetti Printer PG L2028 User Manual
Optoma Technology Projector H77 User Manual
Oregon Marine Radio SL 103 User Manual
Oster Waffle Iron CKSTWF2502 2500 User Manual
Panasonic Network Card MALT062H User Manual