SERIES
FX-301
Digital Fiber Sensor
Superior performance and
advanced user-friendly
multi-functionality
enables expert usage on
the very first day
* Passed the UL 991 Environment Test
* UL 61010C-1 compatible, Passed the UL 991 Environment Test based on SEMI S2-0200.
[Category applicable for semiconductor manufacturing: TWW2, Process Equipment]
[Applicable standards: UL 61010C-1]
[Additional test / evaluation standards as per intended use: UL 991, SEMI S2-0200]
Long-range sensing made possible with built-in optical lens
Stable long-term sensing
Enhanced worksite-friendly installability
For the first time in the industry, an
optical ‘double coupling lens’ has been
incorporated directly into the fiber
sensor itself. This lens maximizes the
light emission efficiency, resulting in a
tremendous improvement in the
sensing range. Sensing ranges with
small diameter fibers and ultra-small
diameter fibers, which have become
very popular in recent years due to the
miniaturization of chip components,
have been increased by 50 % over
previous values achieved with other
amplifiers.
The newly developed four-chemical
Our new fiber cutter utilizes a specially
developed two-in-one fiber attachment
that now makes it possible to cut two
fibers simultaneously to exactly the
same length. Also, since the fibers can
be attached to the amplifier while
being fixed in position in the two-in-one
fiber attachment, sensitivity changes
due to variation in the amount of fiber
insertion do not occur.
emitting element that uses the FX-301
(red LED type) suppresses changes
over long periods of time as much as
possible, so that a stable light emitting
level is maintained. There is very little
element deterioration so that stable
and accurate sensing can be
maintained over long periods.
Selectable response time
We offer 4 selectable levels to
correspond with various applications:
the response time 150 !s FAST mode,
the LONG mode, perfect for adverse
environments, and the S-D mode,
especially made for minute detection.
68
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
Optical communication function lets
multiple sensors be adjusted all at once
4 types of light sources available
Equipped with each type of timer
In addition to our red LED (four-chemical
emitting element) type, the blue, green,
and infrared LED types are also provided
to correspond to your specific application.
The optical communication function
allows the data that is currently set to
be copied and saved all at once for all
amplifiers connected together from the
right side. This greatly reduces
troublesome setup tasks and makes
setup much smoother.
These sensors are equipped with 3
types of timers, ON-delay, OFF-delay,
and ONE SHOT, for compatibility to
variegated environments.
Ⅵ ON-delay timer
This function is useful for sensing only
objects taking a long time travel.
Ⅵ OFF-delay timer
This function is useful when the
connected device has a slow response
time.
Ⅵ ONE SHOT timer
This function is useful when the input
specifications of the connected device
require a signal of fixed width.
Easy code input setting
Every function can be directly set merely by the input of a four digit code (numbers) from the code table. This convenient
feature is easy to set up.
In the event that settings are accidentally changed at the operating site, merely entering the correct code can restore the
original settings. This results in easy and quick maintenance.
Invertible digital display
Selectable cable length
The digital display can be inverted as per its orientation once mounted onto the amplifier.
Made available are 3 lengths, 1 m 3.281 ft,
2 m 6.562 ft, and 5 m 16.404 ft, to suit
your application requirements. This helps
reduce the waste caused by cutting cables
and lightens the installation workload.
70
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
Optional units for greater freedom and control when installing
Sensor-PLC connection system
Bank selection unit
SC SERIES
FX-CH SERIES
This wire-saving system enables the
collective connection of up to 16 I/O
devices with an MIL connector.
Scattered installation is also possible
with the help of a sensor separate
unit.
Without directly manipulating the
sensor itself, you can simultaneously
switch up to 16 fiber sensors’ settings
using an external emitted signal.
(Load and save)
mAlso possible with the FX-301 series’ databank
function
APPLICATIONS
Workpieces detection
Sensing semi-transparent stickers
Sensing register marks
The blue LED type greatly reduces the
dampening rate, making it ideal for delicate
sensing.
This standard type of FX-301 using red light
has a four-chemical emitting element for
stable sensing over long periods.
The green LED type can accurately
discriminate between red and yellow, that
cannot be easily detected using red LED
type.
Sensing film meandering
Detecting chip component
Detecting register marks on a
transparent sheet
When detecting registration marks on
transparent film with a thru-beam type, the
S-D (reduced light intensity) mode will
enable minute light intensity fluctuation
sensing.
Infrared LED type is ideal for sensing
environments with light restrictions, such as
places where light-sensitive film is being
handled. (The emission peak wavelength:
940 nm 0.037 mil.) It includes full-auto
teaching function which allows sensitivity to
be set without stopping the workpiece line.
Because of low light intensity fluctuations
when detecting minute moving objects,
decrease the hysteresis in PRO mode and
accurate sensing will be possible in high-
speed mode. This method is optimal for chip
component verification in taping equipment.
71
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
ORDER GUIDE
Quick-connection cable is not supplied with the amplifier. Please order it separately.
Amplifiers
Type
Appearance
Model No.
Emitting element
Output
Red LED
FX-301
Blue LED
FX-301B
FX-301G
FX-301H
FX-301P
FX-301BP
FX-301GP
FX-301HP
NPN open-collector
transistor
Green LED
Infrared LED
Red LED
N
D
Blue LED
PNP open-collector
transistor
Green LED
Infrared LED
P
Quick-connection cable is not supplied with the amplifier. Please order it separately.
Quick-connection cables
Main cable
• CN-73-CⅪ
Type
Model No.
Description
Length: 1 m 3.281 ft
Length: 2 m 6.562 ft
Length: 5 m 16.404 ft
Length: 1 m 3.281 ft
Length: 2 m 6.562 ft
Length: 5 m 16.404 ft
CN-73-C1
CN-73-C2
CN-73-C5
CN-71-C1
CN-71-C2
CN-71-C5
0.15 mm2 3-core cabtyre cable, with connector on one end
Cable outer diameter: "3.0 mm "0.118 in
Main cable
Sub cable
• CN-71-CⅪ
0.15 mm2 1-core cabtyre cable, with connector on one end
Cable outer diameter: "3.0 mm "0.118 in
Sub cable
End plates are not supplied with the amplifier. Please order separately when the amplifiers are mounted in cascade.
End plates
Appearance
Model No.
Description
When cascading multiple amplifiers, or when it
moves depending on the way it is installed on a
DIN rail, these end plates ensure that all
amplifiers are mounted together in a secure and
fully connected manner.
MS-DIN-E
Two pcs. per set
OPTIONS
Amplifier mounting bracket
• MS-DIN-2
Designation
Model No.
Description
Amplifier mounting
bracket
Mounting bracket for amplifier
MS-DIN-2
10 sets of 2 communication window seals and 1 connector seal
Communication window seal:
It prevents malfunction due to transmission signal from another
amplifier, as well as, prevents effect on another amplifier.
Connector seal:
It prevents contact of any metal, etc., with the pins of the quick-
connection cable.
Fiber amplifier
protective seal
Fiber amplifier protective seal
• FX-MB1
FX-MB1
72
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
LIST OF FIBERS
Standard fibers [Thru-beam type (one pair set)]
:LONG
:STD
:FAST
:S-D
Min. sensing object Fiber cable Allowable
Sensing range (mm in ) (Note 1)
Shape of fiber head
(mm in)
under the optimum
condition (Note 2)
length
bending
radius
Type
Model No.
Red LED
Blue LED Green LED Infrared LED
:
Free-cut
19,500 767,715
With lens
5,400 212.598 2,800
2.400 94.488
"0.4 mm
"0.016 in
opaque object
14,000 551.180 2,700 106.299
110.236 1,200 47.244
FT-FM10L
10 m
32.808 ft
10,000 393.700 1,900 74.803 1,400 55.118
3,800 149.606
1,600 62.992
900 35.433
מ 1,000 39.370
מ (Note 3)
מ With lens
400 15.748
200 7.874
130 5.118
מ 155 6.102
77 3.031
55 2.165
מ "0.02 mm
"0.0008 in
opaque object
800 31.496
580 22.835
280 11.024
200 7.874
100 3.937
65 2.559
מ a
FT-SFM2L
FT-B8
2 m
6.562 ft
R25 mm
R0.984 in
1,100 43.307
Lens mountable
220 8.661
110 4.331
75 2.953
מ 100 3.937
50 1.969
30 1.181
מ "0.04 mm
"0.0016 in
opaque object
530 20.866
400 15.748
110 4.331
55 2.165
40 1.575
מ 2 m
6.562 ft
180 7.087
L
1,000 39.370
200 7.874
100 3.937
70 2.756
מ 90 3.543
45 1.772
28 1.102
מ "0.03 mm
"0.0012 in
opaque object
480 18.898
360 14.173
168 6.614
100 3.937
50 1.969
35 1.378
מ FT-NB8
2 m 6.562 ft
(Note 4)
Lens mountable
R25 mm
R0.984 in
FT-FM2
Sleeve 90 mm 3.543 in
Sleeve 40 mm 1.575 in
Fiber
FT-FM2S
FT-FM2S4
FT-T80
R25 mm
R0.984 in
Sleeve
R10 mm
R0.394 in
780 30.709
400 15.748
280 11.024
130 5.118
150 5.906
75 2.953
40 1.575
מ 50 1.969
25 0.984
18 0.709
מ "0.03 mm
"0.0012 in
opaque object
70 2.756
35 1.378
24 0.945
מ 2 m
6.562 ft
Lens mountable
R25 mm
R0.984 in
FT-SFM2
FT-N8
700 27.559
360 14.173
250 9.843
126 4.961
140 5.512
70 2.756
40 1.575
מ 45 1.772
22 0.866
17 0.669
מ "0.03 mm
"0.0012 in
opaque object
R25 mm
R0.984 in
66 2.598
33 1.299
22 0.866
מ 2 m 6.562 ft
(Note 4)
R25 mm
R0.984 in
FT-NFM2
FT-NFM2S
FT-NFM2S4
FT-SNFM2
FT-R80
Sleeve 90 mm 3.543 in
Sleeve 40 mm 1.575 in
Fiber
R25 mm
R0.984 in
Sleeve
270 10.630
50 1.969
25 0.984
16 0.630
מ 16 0.630
"0.025 mm
"0.0010 in
opaque object
140 5.512
100 3.937
49 1.929
24 0.945
12 0.472
8
5
0.315
0.197
מ 2 m
6.562 ft
8
0.315
מ R10 mm
R0.394 in
R25 mm
R0.984 in
530 20.866
230 9.055
Lens mountable
85 3.346
42 1.654
28 1.102
מ 32 1.260
16 0.630
12 0.472
מ "0.04 mm
"0.0016 in
opaque object
44 1.732
22 0.866
16 0.630
מ R25 mm
R0.984 in
2 m
6.562 ft
150 5.906
80 3.150
2,000 78.740
400 15.748
200 7.874
130 5.118
מ 150 5.906
75 2.953
40 1.575
מ "0.05 mm
"0.0019 in
opaque object
1,000 39.370
800 31.496
350 13.780
200 7.874
100 3.937
65 2.559
מ FT-V10
2 m
6.562 ft
400 15.748
200 7.874
140 5.512
70 2.756
80 3.150
40 1.575
28 1.102
מ 30 1.181
15 0.591
12 0.472
מ 40 1.575
20 0.787
14 0.551
מ FT-SFM2SV2
FT-V22
Sleeve part cannot be bent.
Sleeve part cannot be bent.
Sleeve part cannot be bent.
R25 mm
R0.984 in
390 15.354
180 7.087
125 4.921
63 2.480
50 1.969
25 0.984
16 0.630
מ 44 1.732
22 0.866
15 0.591
מ "0.02 mm
"0.0008 in
opaque object
1 m
3.281 ft
26 1.024
13 0.512
8
0.315
מ 175 6.890
28 1.102
14 0.551
10 0.394
מ 10 0.394
80 3.150
60 2.362
27 1.063
14 0.551
5
3
0.197
0.118
מ FT-V41
2 m
6.562 ft
7
5
0.276
0.197
Notes: 1) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the infrared
type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can fluctuate.
Notes: 2) The minimum sensing object size is the value for red LED type. Please contact our office for information on the minimum sensing object size if using
amplifiers other than red LED type.
The optimum condition is the condition when the sensitivity is set so that the sensing output just changes to light incident operation in the object absent
condition.
Notes: 3) Sensing range for a 2 m 6.562 ft long fiber. A 10 m 32.808 ft long fiber will cause damping of the beam and cannot be used.
Notes: 4) The fiber cutter is not supplied as an accessory with FT-NB8 and FT-N8. Please order it separately.
73
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
LIST OF FIBERS
Sharp bending fibers / Flexible fibers [Thru-beam type (one pair set)]
:LONG
:FAST
:S-D
Fiber cable
length
Min. sensing object
under the optimum
condition (Note 2)
Allowable
bending
radius
Sensing range (mm in) (Note 1)
Shape of fiber head
(mm in)
:STD
Type
Model No.
Red LED
Blue LED Green LED Infrared LED
:
Free-cut
Wide area sensing
2,400 94.488 1,200 47.244
800 31.496
400 15.748
240 9.449
מ 3,500 137.795
3,500 137.795
3,500 137.795
3,500 137.795
(Note 3)
"0.3 mm
"0.012 in
opaque object
1,200 47.244
700 27.559
מ 600 23.622
350 13.780
מ Sensing width
32 mm
R1 mm
R0.039 in
FT-WA30
2 m
6.562 ft
1.260 in
W5
ן H69
ן D20
W0.197
ן H2.717
ן D0.787
Wide area sensing
3,500 137.795
1,500 59.055
1,100 43.307
600 23.622
300 11.811
220 8.661
מ 300 11.811
150 5.906
110 4.331
מ 220 8.661
110 4.331
80 3.150
מ Sensing width
"0.25 mm
"0.010 in
opaque object
W
R1 mm
R0.039 in
11 mm
FT-WA8
2 m
6.562 ft
0.433 in
W4.2
W0.165
ן H31ן D13.5 750 29.528
ן H1.220
ן D0.531
Easy mounting ⅐ Top sensing
400 15.748
200 7.874
140 5.512
מ 200 7.874
100 3.937
70 2.756
מ 180 7.087
90 3.543
65 2.559
מ 2,500 98.425
1,200 47.244
"0.08 mm
"0.003 in
opaque object
W3 H8 D12 W0.118 H0.315 D0.472
ן ן ן ן FT-WZ8H
FT-WZ8E
FT-WZ8
850 33.465
410 16.142
Easy mounting ⅐ Side sensing
240 9.449
120 4.724
80 3.150
מ 120 4.724
60 2.362
40 1.575
מ 100 3.937
50 1.969
30 1.181
מ 1,500 59.055
700 27.559
"0.05 mm
"0.0020 in
opaque object
W3 H12 D8 W0.118 H0.472 D0.315
ן ן ן ן R1 mm
R0.039 in
2 m
6.562 ft
500 19.685
210 8.268
Easy mounting ⅐ Front sensing
80 3.150
40 1.575
25 0.984
מ 40 1.575
20 0.787
13 0.512
מ 36 1.417
18 0.709
12 0.472
מ 700 27.559
330 12.992
"0.04 mm
"0.0016 in
opaque object
W8.5 H12 D3 W0.335 H0.472 D0.118
ן ן ן ן 240 9.449
120 4.724
Side-view type with small light
dispersion
1,700 66.929
700 27.559
300 11.811
150 5.906
100 3.937
מ 160 6.299
80 3.150
60 2.362
מ 150 5.906
75 2.953
45 1.772
מ "0.06 mm
"0.0024 in
opaque object
R1 mm
R0.039 in
FT-WKV8
FT-WS8L
2 m
6.562 ft
600 23.622
300 11.811
With lens ⅐ Long sensing range
1,200 47.244
600 23.622
240 9.449
120 4.724
90 3.543
מ 120 4.724
60 2.362
40 1.575
מ 110 4.331
55 2.165
35 1.378
מ "0.02 mm
"0.0008 in
opaque object
R1 mm
R0.039 in
2 m
6.562 ft
420 16.535
210 8.268
"0.03 mm
Lens mountable
"0.0012 in
opaque object
"0.05 mm
"0.0020 in
opaque object
"0.03 mm
FT-W8
570 22.441
290 11.417
90 3.543
45 1.772
30 1.181
מ 56 2.205
28 1.102
20 0.787
מ 42 1.654
21 0.827
15 0.591
מ R1 mm
R0.039 in
FT-WS3
FT-WS8
2 m
6.562 ft
200 7.874
100 3.937
"0.0012 in
opaque object
16 0.630
10 0.394
8
4
0.315
0.157
160 6.299
80 3.150
"0.02 mm
"0.0008 in
opaque object
FT-W4
8
5
0.315
0.197
מ 5
3
0.197
0.118
מ R1 mm
R0.039 in
2 m
6.562 ft
2.5 0.098
55 2.165
FT-WS4
מ 28 1.102
מ מ מ מ מ מ מ מ מ מ מ מ 90 3.543
40 1.575
30 1.181
"0.02 mm
"0.0008 in
opaque object
R1 mm
R0.039 in
FT-WV42
FT-Z8H
FT-Z8E
FT-Z8
2 m
6.562 ft
Sleeve part cannot be bent. 15 0.591
Easy mounting ⅐ Top sensing
560 22.047
280 11.024
200 7.874
מ 200 7.874
100 3.937
65 2.559
מ 180 7.087
90 3.543
65 2.559
מ 2,700 106.299
W3 H8 D12 W0.118 H0.315 D0.472
ן ן ן ן 1,400 55.118
1,000 39.370
490 19.291
Easy mounting ⅐ Side sensing
400 15.748
200 7.874
140 5.512
מ 200 7.874
100 3.937
65 2.559
מ 140 5.512
70 2.756
50 1.969
מ 1,600 62.992
800 31.496
600 23.622
280 11.024
"0.03 mm
"0.0012 in
opaque object
W3 H12 D8 W0.118 H0.472 D0.315
ן ן ן ן R4 mm
R0.157 in
2 m
6.562 ft
Easy mounting ⅐ Front sensing
120 4.724
60 2.362
40 1.575
מ 60 2.362
30 1.181
22 0.866
מ 46 1.811
23 0.906
16 0.630
מ 800 31.496
W8.5 H12 D3 W0.335 H0.472 D0.118
ן ן ן ן 400 15.748
300 11.811
140 5.512
130 5.118
65 2.559
45 1.772
מ 70 2.756
35 1.378
25 0.984
מ 56 2.205
28 1.102
20 0.787
מ Lens mountable
Lens mountable
650 25.591
320 12.598
230 9.055
FT-P80
FT-P60
FT-P40
FT-P2
"0.04 mm
"0.0016 in
opaque object
110 4.331
R4 mm
R0.157 in
2 m
6.562 ft
50 1.969
25 0.984
18 0.709
מ 26 1.024
13 0.512
20 0.787
10 0.394
400 15.748
190 7.480
140 5.512
80 3.150
8
0.315
מ 7
0.276
מ 32 1.260
16 0.630
12 0.472
מ 18 0.709
14 0.551
250 9.843
100 3.937
75 2.953
9
7
0.354
0.276
מ 7
5
0.276
0.197
מ 2 m
6.562 ft
35 1.378
20 0.787
10 0.394
18 0.709
280 11.024
120 4.724
90 3.543
36 1.417
18 0.709
14 0.551
מ "0.02 mm
"0.0008 in
opaque object
1 m
3.281 ft
9
7
0.354
0.276
מ R4 mm
R0.157 in
8
0.315
מ 42 1.654
80 3.150
40 1.575
30 1.181
17 0.669
14 0.551
6
3
2
0.236
0.118
0.079
מ 14 0.551
500 mm
7
4
0.276
0.157
מ 7
4
0.276
0.157
מ FT-PS1
19.685 in
Notes: 1) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the infrared
type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can fluctuate.
Notes: 2) The minimum sensing object size is the value for red LED type. Please contact our office for information on the minimum sensing object size if using amplifiers other than red LED
type. The optimum condition is the condition when the sensitivity is set so that the sensing output just changes to light incident operation in the object absent condition.
Notes: 3) The fiber cable length practically limits the sensing range to 3,500 mm 137.795 in long.
74
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
LIST OF FIBERS
Special use fibers [Thru-beam type (one pair set)]
:LONG
:STD
:FAST
:S-D
Min. sensing object Fiber cable Allowable
Sensing range (mm in) (Note 1)
Red LED
Shape of fiber head
(mm in)
under the optimum
condition (Note 2)
length
bending
radius
Type
Model No.
Blue LED Green LED Infrared LED
:
Free-cut
3,500 137.795 2,400 94.488 1,200 47.244
800 31.496
400 15.748
240 9.449
מ Sensing width
32 mm
"0.3 mm
"0.012 in
opaque object
3,500 137.795 1,200 47.244
600 23.622
350 13.780
מ R10 mm
R0.394 in
2 m
6.562 ft
3,500 137.795
3,500 137.795
(Note 3)
700 27.559
מ 1.260 in
FT-A30
W5
ן H69ן D20 W0.197
ן H2.717ן D0.787
Sensing width
3,500 137.795
600 23.622
300 11.811
220 8.661
מ 300 11.811
150 5.906
110 4.331
מ 220 8.661
110 4.331
80 3.150
מ "0.25 mm
"0.010 in
opaque object
11 mm
1,500 59.055
R10 mm
R0.394 in
W
W0.44.233 Hin31
2 m
6.562 ft
FT-A8
1,100 43.307
D13.5
ן ן 750 29.528
650 25.591
330 12.992
W0.165 H1.220 D0.531
ן ן Top sensing
Horizontal:
120 4.724
60 2.362
40 1.575
מ 60 2.362
30 1.181
20 0.787
מ 48 1.890
24 0.945
18 0.709
מ W5 H15 D15 W0.197 H0.591 D0.591
ן ן ן ן "0.025 mm
FT-AFM2
FT-AFM2E
FT-K8
"0.0010 in
opaque object
Vertical:
"0.45 mm
"0.018 in
220 8.661
115 4.528
y
R25 mm
R0.984 in
a
2 m
6.562 ft
Side sensing
590 23.228
120 4.724
60 2.362
40 1.575
מ 60 2.362
30 1.181
20 0.787
מ 48 1.890
24 0.945
18 0.709
מ W5 H15 D15 W0.197 H0.591 D0.591
ן ן ן ן 290 11.417
200 7.874
100 3.937
opaque object
2,000 78.740
1,000 39.370
800 31.496
400 15.748
200 7.874
130 5.118
מ 200 7.874
100 3.937
65 2.559
מ 150 5.906
75 2.953
40 1.575
מ "0.06 mm
"0.0024 in
opaque object
R25 mm
R0.984 in
2 m
6.562 ft
Side-view
Side-view
350 13.780
FT-KV8
FT-KV1
FT-E12
FT-E22
FT-P81X
500 19.685
80 3.150
35 1.378
10 0.394
מ מ מ מ מ מ מ מ מ "0.02 mm
"0.0008 in
opaque object
W2
ן H1.5 ן D20 W0.079
ן H0.059
ן D0.787
250 9.843
180 7.087
100 3.937
R10 mm
R0.394 in
2 m
6.562 ft
"
"
Beam diameter: 0.125 mm 0.005 in
18 0.709
3
2
1
0.118
0.079
0.039
מ 1
0.039
מ מ מ 4
2
0.157
0.079
10 0.394
8 0.315
3 0.118
500 mm
19.685 in
1.5 0.059
"0.02 mm
"0.0008 in
opaque object
מ Sleeve part cannot be bent.
Beam diameter: 0.25 mm 0.010 in
R5 mm
R0.197 in
"
"
80 3.150
14 0.551
6
3
2
0.236
0.118
0.079
מ 10 0.394
7
4
0.276
0.157
מ 5
3
0.197
0.118
מ 1 m
3.281 ft
50 1.969
36 1.417
15 0.591
Sleeve part cannot be bent.
Lens mountable
650 25.591
130 5.118
64 2.520
45 1.772
מ 64 2.520
32 1.260
22 0.866
מ 130 5.118
64 2.520
45 1.772
מ "0.05 mm
"0.0020 in
opaque object
320 12.598
230 9.055
110 4.331
1 m
3.281 ft
R10 mm
R0.394 in
Notes: 1) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the
infrared type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can
fluctuate.
Notes: 2) The minimum sensing object size is the value for red LED type. Please contact our office for information on the minimum sensing object size if using
amplifiers other than red LED type.
The optimum condition is the condition when the sensitivity is set so that the sensing output just changes to light incident operation in the object absent
condition.
Notes: 3) The fiber cable length practically limits the sensing range to 3,500 mm 137.795 in long.
75
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
LIST OF FIBERS
Environment resistant fibers [Thru-beam type (one pair set)]
:LONG
:STD
:FAST
:S-D
Min. sensing object
under the optimum
condition (Note 2)
Allowable
bending
radius
Fiber cable
length
Sensing range (mm in) (Note 1)
Red LED
Shape of fiber head
(mm in)
Type
Model No.
Blue LED Green LED Infrared LED
:
Free-cut
350 ЊC 662 ЊF
Lens mountable
R25 mm
R0.984 in
FT-H35-M2
550 21.654
280 11.024
200 7.874
100 3.937
50 1.969
35 1.378
מ 50 1.969
25 0.984
18 0.709
מ 420 16.535
210 8.268
160 6.299
מ "0.04 mm
"0.0016 in
opaque object
2 m
6.562 ft
Fiber
R25 mm
R0.984 in
Sleeve
350 ЊC 662 ЊF
Sleeve 60 mm 2.362 in
90 3.543
FT-H35-M2S6
FT-H20W-M1
FT-H20W-M2
FT-H20-M1
R10 mm
R0.394 in
Allows flexible wiring
200 ЊC 392 ЊF
Lens mountable
1 m
3.281 ft
310 12.205
140 5.512
44 1.732
22 0.866
14 0.551
מ 22 0.866
11 0.433
220 8.661
110 4.331
70 2.756
מ "0.02 mm
"0.0008 in
opaque object
R10 mm
R0.394 in
100 3.937
7
0.276
מ 50 1.969
2 m
6.562 ft
200 ЊC 392 ЊF
Lens mountable
550 21.654
280 11.024
200 7.874
90 3.543
100 3.937
50 1.969
35 1.378
מ 50 1.969
25 0.984
18 0.709
מ 420 16.535
210 8.268
160 6.299
מ "0.04 mm
"0.0016 in
opaque object
1 m
3.281 ft
R25 mm
R0.984 in
130 ЊC 266 ЊF
Lens mountable
880 34.646
440 17.323
300 11.811
155 6.102
72 2.835
36 1.417
26 1.024
מ 32 1.260
16 0.630
10 0.394
מ 70 2.756
35 1.378
25 0.984
מ "0.06 mm
"0.0024 in
opaque object
FT-H13-FM2
2 m
6.562 ft
Easy mounting ⅐ Rectangular head
SEMI S2 compliant
W7 H15 D13
ן ן 320 12.598
160 6.299
120 4.724
מ 160 6.299
80 3.150
60 2.362
מ 320 12.598
160 6.299
120 4.724
מ 3,500 137.795
"4 mm
"0.157 in
opaque object
W0.276 H0.591 D0.512
ן ן R25 mm
1,500 59.055
2 m
6.562 ft
FT-Z802Y
1,000 39.370
530 20.866
R0.984 in
3,500 137.795
1,500 59.055
1,000 39.370
160 6.299
80 3.150
50 1.969
מ 160 6.299
80 3.150
50 1.969
מ 400 15.748
200 7.874
150 5.906
מ FT-L8Y
FT-V8Y
FT-6V
"0.08 mm
"0.003 in
opaque object
530 20.866
800 31.496
400 15.748
280 11.024
140 5.512
2 m
R30 mm
Side-view
6.562 ft R1.181 in
(Note 3)
120 4.724
60 2.362
35 1.378
מ 80 3.150
40 1.575
25 0.984
מ 75 2.953
38 1.496
24 0.945
מ Lens mountable
470 18.504
100 3.937
50 1.969
30 1.181
מ 46 1.811
23 0.906
16 0.630
מ 70 2.756
35 1.378
22 0.866
מ 230 9.055
165 6.496
R200 mm
R7.874 in
"0.02 mm
"0.0008 in
opaque object
80 3.150
1 m
3.281 ft
220 8.661
100 3.937
75 2.953
35 1.378
36 1.417
18 0.709
12 0.472
מ 18 0.709
28 1.102
14 0.551
10 0.394
מ 9
6
0.354
0.236
מ R30 mm
R1.181 in
FT-60V
Notes: 1) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the infrared
type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can fluctuate.
Notes: 2) The minimum sensing object size is the value for red LED type. Please contact our office for information on the minimum sensing object size if using amplifiers other than red
LED type. The optimum condition is the condition when the sensitivity is set so that the sensing output just changes to light incident operation in the object absent condition.
Notes: 3) The allowable cutting range is 500 mm 19.685 in from the end that the amplifier inserted.
The vacuum type fiber must be used with the following products as a set.
FT-J6: Fiber at atmospheric side (one pair set) FV-BR1: Photo-terminal (one pair set)
Semi-standard fibers (Custom made per order)
The fiber cable length or sleeve length of the standard fibers can be modified at your request. Select the fiber cable length (symbol ଁ ) or the sleeve length
(symbol f ) from the table below.
Correlation between sensing
range attenuation coefficient and
fiber cable length
Fiber cable length
(Unit: m ft)
ଁ
Sleeve length
(Unit: cm in)
f
Basic model No.
Type
The longer the fiber cable, the shorter the
sensing range.
Standard threaded
head (free-cut)
3 9.843, 4 13.123, 5 16.404, 10 32.808,
15 49.213, 20 65.617,25 82.021, 30 98.425
FT-FM ଁ
2
6.562 (Note),
3
9.843,
4
13.123,
5
16.404, 1 0.394, 2 0.787, 3 1.181, 4 1.575, 5 1.969, 6 2.362,
With sleeve
FT-FM ଁ -S f
FT-FM ଁ L
10 32.808, 15 49.213, 20 65.617, 25 82.021, 30 98.425 7 2.756, 8 3.150, 9 3.543, 10 3.937, 11 4.331, 12
4.724
With large diameter lens
20 65.617, 30 98.425
Small diameter threaded
head with sleeve (free-cut)
FT-NFM2-S f
1 0.394, 2 0.787, 3 1.181, 4 1.575, 5 1.969, 6 2.362,
7 2.756, 8 3.150, 9 3.543, 10 3.937, 11 4.331, 12
4.724
FT-WA30- ଁ
FT-WA8- ଁ
FT-A30- ଁ
FT-A8- ଁ
Wide beam
5 16.404
200ЊC 392ЊF heat-resistant
350ЊC 662ЊF heat-resistant
Chemical-resistant
2 6.562, 3 9.843
3 9.843
FT-H20-M ଁ
FT-H35-M ଁ
FT-Z80 ଁ Y
5 16.404, 7 22.966
Note: The standard fiber has a 2 m 6.562 ft fiber cable length and a 4 cm 1.575 in or 9 cm 3.543 in sleeve length.
76
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
LIST OF FIBERS
Standard fibers (Reflective type)
:LONG
:STD
:FAST
:S-D
Min. sensing object
at the maximum
sensitivity (Note 3)
Allowable
bending
radius
Fiber cable
length
Sensing range (mm in ) (Note 1, 2)
Shape of fiber head
(mm in)
Type
Model No.
Red LED
Blue LED Green LED Infrared LED
:
Free-cut
480 18.898
220 8.661
160 6.299
80 3.150
40 1.575
26 1.024
מ 42 1.654
21 0.827
14 0.551
מ 26 1.654
13 0.827
a
"0.02 mm
"0.0008 in
gold wire
FD-B8
2 m
6.562 ft
9
0.551
מ 75 2.953
L
Coaxial
310 12.205
46 1.811
23 0.906
15 0.591
מ 24 0.945
12 0.472
90 3.543
45 1.772
30 1.181
מ 500 mm
19.685 in
140 5.512
100 3.937
47 1.850
R25 mm
R0.984 in
FD-5
8
0.315
מ "0.02 mm
"0.0008 in
gold wire
310 12.205
46 1.811
23 0.906
15 0.591
מ 24 0.945
12 0.472
20 0.787
10 0.394
140 5.512
100 3.937
47 1.850
FD-FM2
FD-FM2S
FD-FM2S4
FD-T80
2 m
6.562 ft
8
0.315
מ 7
0.276
מ Sleeve 90 mm 3.543 in
Sleeve 40 mm 1.575 in
Fiber
R25 mm
R0.984 in
Sleeve
R10 mm
R0.394 in
270 10.630
46 1.811
23 0.906
15 0.591
מ 24 0.945
12 0.472
20 0.787
10 0.394
"0.02 mm
"0.0008 in
gold wire
110 4.331
85 3.346
39 1.535
2 m
6.562 ft
8
0.315
מ 7
0.276
מ 270 10.630
46 1.811
23 0.906
15 0.591
מ 24 0.945
12 0.472
20 0.787
10 0.394
110 4.331
85 3.346
39 1.535
8
0.315
מ 7
0.276
מ Small diameter
90 3.543
16 0.630
8
4
2
0.315
0.157
0.079
מ 6
3
2
0.236
0.118
0.079
מ "0.02 mm
"0.0008 in
gold wire
8
5
0.315
0.197
מ R25 mm
R0.984 in
45 1.772
35 1.378
16 0.630
2 m
6.562 ft
FD-T40
270 10.630
260 10.236
46 1.811
23 0.906
15 0.591
מ 24 0.945
12 0.472
20 0.787
10 0.394
110 4.331
FD-S80
8
0.315
מ 7
0.276
מ 85 3.346
39 1.535
46 1.811
23 0.906
15 0.591
מ 24 0.945
12 0.472
20 0.787
10 0.394
120 4.724
85 3.346
42 1.654
FD-N8
8
0.315
מ 7
0.276
מ "0.02 mm
"0.0008 in
gold wire
2 m
6.562 ft
(Note 4)
R25 mm
R0.984 in
75 2.953
38 1.496
28 1.102
13 0.512
16 0.630
8
4
2
0.315
0.157
0.079
מ 4
2
0.157
0.079
8
5
0.315
0.197
מ FD-N4
1.5 0.059
מ R25 mm
R0.984 in
FD-NFM2
FD-NFM2S
FD-NFM2S4
FD-SNFM2
FD-R80
Sleeve 90 mm 3.543 in
Sleeve 40 mm 1.575 in
Fiber
R25 mm
R0.984 in
Sleeve
90 3.543
45 1.772
35 1.378
16 0.630
16 0.630
8
4
2
0.315
0.157
0.079
מ 6
3
2
0.236
0.118
0.079
מ "0.02 mm
"0.0008 in
gold wire
8
5
0.315
0.197
מ 2 m
6.562 ft
R10 mm
R0.394 in
R25 mm
R0.984 in
185 7.283
32 1.260
16 0.630
10 0.394
מ 16 0.630
10 0.472
"0.02 mm
"0.0008 in
gold wire
85 3.346
60 2.362
30 1.181
8
5
0.315
0.197
מ 5
3
0.197
0.118
מ R25 mm
R0.984 in
2 m
6.562 ft
100 3.937
45 1.772
32 1.260
16 0.630
14 0.551
7
0.276
4
0.157
מ מ מ 7
4
0.276
0.157
מ 3.5 0.138
מ מ FD-SFM2SV2
FD-V41
"0.02 mm
"0.0008 in
gold wire
Sleeve part cannot be bent.
Small diameter
R25 mm
R0.984 in
2 m
6.562 ft
55 2.165
6
3
0.236
0.118
מ 3
0.118
מ מ מ מ מ מ מ 25 0.984
17 0.669
9 0.354
מ Sleeve part cannot be bent.
Notes: 1) The sensing range is specified for white non-glossy paper (FD-B8, FD-5, FD-FM2, FD-FM2S, FD-FM2S4, FD-N8, FD-T80, FD-S80 and FD-R80:
400
ן 400 mm 15.748ן 15.748 in, FD-T40, FD-N4, FD-NFM2, FD-NFM2S, FD-NFM2S4, FD-SNFM2, FD-SFM2SV2 and FD-V41: 200ן 200 mm 7.874
ן 7.874 in) as the object. Notes: 2) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the
infrared type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can
fluctuate.
Notes: 3) The minimum sensing object size is the value for red LED type at maximum sensitivity. Please contact our office for information on the minimum sensing
object size if using amplifiers other than red LED type.
Also, note that the corresponding setting distance is different from the rated sensing distance.
Notes: 4) The fiber cutter is not supplied as an accessory with FD-N8 and FD-N4. Please order it separately.
77
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
LIST OF FIBERS
Sharp bending fibers / Flexible fibers (Reflective type)
:LONG
:STD
:FAST
:S-D
Allowable
bending
radius
Min. sensing object
at the maximum
sensitivity (Note 3)
Fiber cable
length
Sensing range (mm in) (Note 1, 2)
Red LED
Shape of fiber head
(mm in)
Type
Model No.
Blue LED Green LED Infrared LED
:
Free-cut
Long sensing range ⅐ Rectangular head
20 to 480 0.787 to 18.898
20 to 230 0.787 to 9.055
20 to 170 0.787 to 6.693
מ מ מ מ מ מ מ מ מ מ מ מ a
"0.3 mm
"0.012 in
copper wire
R1 mm
R0.039 in
FD-WKZ1
2 m
6.562 ft
25 to 100 0.984 to 3.937
L
190 7.480
90 3.543
60 2.362
32 1.260
23 0.906
11 0.433
14 0.551
11 0.433
5.5 0.217
7
4
0.276
0.157
מ R1 mm
R0.039 in
FD-W8
8
0.315
מ 3
0.118
מ Sleeve 40 mm 1.575 in
Fiber
R1 mm
30 1.181
15 0.591
12 0.472
5 0.197
5
0.197
3
0.118
2
1
0.079
0.039
מ R0.039 in
2.5 0.098
1.5 0.059
מ 1.5 0.059
FD-W44
1
0.039
מ Sleeve
R10 mm
R0.394 in
מ "0.02 mm
"0.0008 in
gold wire
2 m
6.562 ft
FD-WT8
FD-WS8
FD-WT4
FD-WG4
FD-WSG4
FD-WL41
FD-WL42
FD-WV42
FD-P80
190 7.480
90 3.543
60 2.362
23 0.906
11 0.433
14 0.551
11 0.433
5.5 0.217
7
4
0.276
0.157
מ 8
0.315
מ 3
0.118
מ 32 1.260
R1 mm
R0.039 in
30 1.181
5
0.197
3
0.118
2
1
0.079
0.039
מ 2.5 0.098
1.5 0.059
מ 1.5 0.059
15 0.591
12 0.472
5 0.197
1
0.039
מ מ Small spot for sensing minute objects
Coaxial ⅐ Lens mountable
65 2.559
11 0.433
6
3
2
0.236
0.118
0.079
מ 5
0.197
"0.02 mm
"0.0008 in
gold wire
5
3
0.197
0.118
מ 2.5 0.098
1.5 0.059
מ 32 1.260
25 0.984
11 0.433
R2 mm
R0.079 in
2 m
6.562 ft
For sensing minute objects ⅐ Coaxial
Glass substrate detection
6.5 to 14 0.256 to 0.551 (Convergent point 8 0.315)
7 to 12 0.276 to 0.472 (Convergent point 8 0.315)
7.5 to 12 0.295 to 0.472 (Convergent point 8 0.315)
מ מ מ מ מ מ מ מ מ מ מ מ "1.9 mm
"0.075 in
metal pipe (gray)
W24 H21 D4
ן ן W0.945 H0.827 0.157
ן ן Cannot use
R1 mm
R0.039 in
2 m
6.562 ft
Specular object detection
0.6 to 3.5 0.024 to 0.138 (Convergent point 2 0.079)
0.9 to 2.7 0.035 to 0.106 (Convergent point 2 0.079)
1 to 2.5 0.039 to 0.098 (Convergent point 2 0.079)
מ מ מ מ מ מ מ מ מ מ מ מ "0.08 mm
"0.003 in
gold wire
W15 H19 D3
ן ן W0.591 H0.748 0.118
ן ן Cannot use
15 0.591
7 0.276
מ מ מ מ מ מ מ מ מ מ מ מ "0.02 mm
"0.0008 in
gold wire
R1 mm
R0.039 in
2 m
6.562 ft
5 0.197
Cannot use
Sleeve part cannot be bent.
220 8.661
100 3.937
40 1.575
20 0.787
13 0.512
מ 20 0.787
10 0.394
18 0.709
9
6
0.354
0.236
מ 7
0.276
מ 70 2.756
35 1.378
FD-P60
20 0.787
10 0.394
10 0.394
8
4
0.315
0.157
90 3.543
45 1.772
5
3
0.197
0.118
מ 6
0.236
מ 2.5 0.098
30 1.181
2 m
6.562 ft
מ "0.02 mm
"0.0008 in
gold wire
16 0.630
R4 mm
R0.157 in
FD-P50
36 1.417
18 0.709
5
0.197
3
0.118
2
1
0.079
0.039
מ 2.5 0.098
1.5 0.059
מ 1.5 0.059
FD-P40
1
0.039
מ 14 0.551
מ 6 0.236
50 1.969
25 0.984
8
4
0.315
0.157
4
2
0.157
0.079
7
0.276
3.5 0.138
1 m
3.281 ft
FD-P2
2.5 0.098
1.5 0.059
2
0.079
מ 19 0.748
מ מ 9 0.354
Notes: 1) The sensing range is specified for white non-glossy paper [100
ן 100 mm 3.937ן 3.937 in (FD-WKZ1, FD-W8, FD-WT8, FD-WS8 and FD-P80: 400
ן 400 mm 15.748ן 15.748 in, FD-WG4, FD-WSG4, FD-P60 and FD-P50: 200ן 200 mm 7.874ן 7.874 in, FD-WL41: glass substrate 100
ן 100ן t 2 mm 3.937ן 3.937ן t 0.472 in)] as the object. Notes: 2) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the
infrared type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can
fluctuate.
Notes: 3) The minimum sensing object size is the value for red LED type at maximum sensitivity. Please contact our office for information on the minimum sensing
object size if using amplifiers other than red LED type.
Also, note that the corresponding setting distance is different from the rated sensing distance. However, with the fixed-focus reflective type, when the
sensitivity is at MAX., it is only possible to detect the minimum size of the sensing object at a distance corresponding to the convergent point.
78
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
LIST OF FIBERS
Special use fibers (Reflective type)
:LONG
:STD
:FAST
:S-D
Min. sensing object
at the maximum
Blue LED Green LED Infrared LED
sensitivity (Note 3)
Allowable
bending
radius
Fiber cable
length
Sensing range (mm in) (Note 1, 2)
Shape of fiber head
(mm in)
Type
Model No.
Red LED
:
Free-cut
W7 H15 D30 W0.276 H0.591 D1.181
200 7.874
150 5.906
100 3.937
ן ן ן ן 25 0.984
15 0.591
מ מ מ מ מ מ מ מ מ "0.02 mm
"0.0008 in
gold wire
R25 mm
R0.984 in
FD-A15
2 m
6.562 ft
50 1.969
מ W
Top sensing
W5 H20 D20
ן ן 220 8.661
110 4.331
78 3.071
FD-AFM2
FD-AFM2E
FD-G4
40 1.575
20 0.787
13 0.512
מ 18 0.709
12 0.472
y
"0.02 mm
"0.0008 in
gold wire
W0.197 H0.787 D0.787
ן ן R25 mm
R0.984 in
a
9
5
0.354
0.197
מ 6
4
0.236
0.157
מ 2 m
6.562 ft
Side sensing
W5 H20 D20
A
39 1.535
ן ן W0.197 H0.787 D0.787
ן ן Coaxial ⅐ Lens mountable
Coaxial ⅐ Lens mountable
Coaxial ⅐ Lens mountable
110 4.331
22 0.866
11 0.433
12 0.472
7
0.276
55 2.165
42 1.654
19 0.748
6
4
0.236
0.157
מ 3.5 0.138
2 m
6.562 ft
8
0.315
2
0.079
"0.02 mm
"0.0008 in
gold wire
מ מ R25 mm
R0.984 in
FD-G6
38 1.496
18 0.709
14 0.551
6 0.236
6
3
2
0.236
0.118
0.079
מ 3
0.118
10 0.394
1.5 0.059
5
3
0.197
0.118
מ FD-EG1
FD-EG2
FD-EG3
FD-E12
1
0.039
מ Coaxial ⅐ Lens mountable
25 0.984
12 0.472
9 0.354
5
2
1
0.197
0.079
0.039
מ 2
1
0.079
0.039
מ 6
3
2
0.236
0.118
0.079
מ 500 mm
19.685 in
"0.04 mm
"0.0016 in
gold wire
5 0.197
מ R10 mm
R0.394 in
Coaxial ⅐ Lens mountable
15 0.591
8 0.315
2
1
0.079
0.039
מ 1
1
3
0.039
מ 3
0.118
1.5 0.059
5 0.197
3 0.118
מ 1
0.039
מ מ מ 11 0.433
6 0.236
4 0.157
1 0.039
2
1
0.079
0.039
מ 0.039
מ 1
0.039
מ R10 mm
R0.394 in
מ מ מ מ מ Sleeve part cannot be bent.
1 m
3.281 ft
Coaxial
45 1.772
23 0.906
17 0.669
6
3
2
0.236
0.118
0.079
מ 0.118
6
3
2
0.236
0.118
0.079
מ 1.5 0.059
FD-E22
1
0.039
"0.02 mm
"0.0008 in
gold wire
7 0.276
מ Sleeve part cannot be bent.
5 0.197
מ מ מ מ מ מ מ מ מ מ מ מ R25 mm
R0.984 in
500 mm
19.685 in
3 0.118
FD-EN500S1
2 0.079
Cannot use
Sleeve part cannot be bent.
Coaxial
38 1.496
18 0.709
14 0.551
6 0.236
6
3
2
0.236
0.118
0.079
מ 3
0.118
4
2
0.157
0.079
1 m
3.281 ft
1.5 0.059
FD-ENM1S1
FD-L43
1
0.039
1.5 0.059
מ מ Sleeve part cannot be bent.
GSlEasMs sIuSbs2tracteodmetpeclitiaonnt
R4
R0.157
0 to 20 0 to 0.787
מ מ מ (LCD glass)
W17 H29 D3.8
ן H1.142ן D0.150 W0.669
ן ן GWla2ss4subsHtra2te1detecDtio4n
2.5 to 18 0.098 to 0.709 (Convergent point 8 0.315)
3 to 16 0.118 to 0.630 (Convergent point 8 0.315)
3.5 to 15 0.138 to 0.591 (Convergent point 8 0.315)
מ מ מ מ מ מ מ מ מ מ מ מ "0.06 mm
"0.0024 in
gold wire
ן ן ן FD-L41
W0.945 H0.827 D0.157
ן Cannot use
Specular object detection
2 m
6.562 ft
0.5 to 4 0.020 to 0.157 (Convergent point 2 0.079)
1 to 3.8 0.039 to 0.150 (Convergent point 2 0.079)
1.3 to 3.5 0.051 to 0.138 (Convergent point 2 0.079)
מ מ מ מ מ מ מ מ מ מ מ מ "0.03 mm
"0.0012 in
gold wire
W15 H19 D3
R10 mm
R0.394 in
ן ן FD-L42
W0.591 H0.748 D0.118
ן ן Cannot use
2.5 to 18 0.098 to 0.709 (Convergent point 6 0.236)
4 to 12 0.157 to 0.472 (Convergent point 6 0.236)
4.5 to 11 0.177 to 0.433 (Convergent point 6 0.236)
4.8 to 9.5 0.189 to 0.374 (Convergent point 6 0.236)
W6 H18 D14
ן ן 4.5 to 9.5 0.177 to 0.374
5
to
9
8
0.197 to 0.354
0.217 to 0.315
מ 4.5 to 9.5 0.177 to 0.374
מ מ "0.02 mm
"0.0008 in
gold wire
5
to
9
8
0.197 to 0.354
0.217 to 0.315
מ 5.5 to
W0.236 H0.709 D0.551
ן ן FD-L4
5.5 to
מ מ Contact type
"6 "0.236
Protective tube
R40 mm R1.575 in
Fiber
FD-F8Y
(Liquid)
2 m 6.562 ft
(Note 4)
R15 mm R0.591 in
Mountable on pipe
Standard
2 m
Applicable pipe diameter:
Outer dia. "6 to "26 mm "0.236 to "1.024 in transparent pipe
FD-F41
FD-F91
FD-F4
FD-F9
6.562 ft
W25 H13 D20
ן ן 5 m
16.404 ft
[PVC, fluorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in]
W0.984 H0.512 D0.787
ן ן R10 mm
R0.394 in
(Liquid)
Mountable on pipe ⅐ For PFA, wall
2 m
6.562 ft
Applicable pipe diameter:
Outer dia. "6 to "26 mm "0.236 to "1.024 in transparent pipe
[PFA (fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in]
thickness 1 mm 0.039 in pipe
W25 H13 D20
ן ן 5 m
16.404 ft
W0.984 H0.512 D0.787
ן ן 185 7.283
32 1.260
16 0.630
10 0.394
מ 16 0.630
30 1.181
15 0.591
10 0.394
מ 1 m
3.281 ft
80 3.150
60 2.362
35 1.378
8
5
0.315
0.197
מ FD-P81X
FD-G6X
"0.02 mm
"0.0008 in
gold wire
R10 mm
R0.394 in
Small spot for sensing minute objects
90 3.543
22 0.866
11 0.433
12 0.472
18 0.709
45 1.772
35 1.378
20 0.787
6
4
0.236
0.157
מ 9
5
0.354
0.197
מ 1 m 3.281 ft
(Note 4)
6
0.236
מ Coaxial ⅐ High precision
Notes: 1) The sensing range is specified for white non-glossy paper [100
FD-AFM2, FD-AFM2E, FD-P81X: 400 400 mm 15.748
glass substrate 100 100 t 2 mm 3.937 3.937 t 0.079 in)] as the object.
ן 100 mm 3.937
15.748 in, FD-L43: glass substrate 76
ן 3.937 in (FD-A15, FD-G4, FD-G6X: 200
ן 200 mm 7.874
ן 7.874 in, ן ן ן 52 t 1.1 mm 2.992
ן ן 2.047 t 0.043 in, FD-L41:
ן ן ן ן ן Notes: 2) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the
infrared type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can
fluctuate.
Notes: 3) The minimum sensing object size is the value for red LED type at maximum sensitivity. Please contact our office for information on the minimum sensing
object size if using amplifiers other than red LED type.
Also, note that the corresponding setting distance is different from the rated sensing distance. However, with the fixed-focus reflective type, when the
sensitivity is at MAX., it is only possible to detect the minimum size of the sensing object at a distance corresponding to the convergent point.
Notes: 4) Following is the allowable cutting range from the end that the amplifier is inserted FD-F8Y: 1,000 mm 39.370 in, FD-G6X: 700 mm 27.559 in.
79
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
LIST OF FIBERS
Environment resistant fibers (Reflective type)
:LONG
:STD
:FAST
:S-D
Allowable
bending
radius
Min. sensing object Fiber cable
Sensing range (mm in) (Note 1, 2)
Red LED
Shape of fiber head
(mm in)
length
Type
at the maximum
sensitivity (Note 3)
Model No.
Blue LED Green LED Infrared LED
:
Free-cut
350 ЊC 662 ЊF ⅐ Coaxial
R25 mm
R0.984 in
FD-H35-M2
2 m
6.562 ft
Fiber
R25 mm
R0.984 in
Sleeve
350 ЊC 662 ЊF ⅐ Sleeve 60 mm 2.362 in
270 10.630
270 10.630
310 12.205
36 1.417
18 0.709
12 0.472
מ 20 0.787
10 0.394
140 5.512
70 2.756
45 1.772
מ "0.02 mm
"0.0008 in
gold wire
140 5.512
100 3.937
47 1.850
FD-H35-M2S6
FD-H20-M1
FD-H35-20S
FD-H20-21
FD-H30-L32
FD-H18-L31
FD-H13-FM2
FD-6V
7
0.276
מ R10 mm
R0.394 in
200 ЊC 392 ЊF ⅐ Coaxial
R25 mm
R0.984 in
1 m
3,281 ft
Fiber
R25 mm
R0.984 in
Sleeve
R10 mm
R0.394 in
350 ЊC 662 ЊF ⅐ Sleeve 90 mm 3.543 in
160 6.299
80 3.150
57 2.244
26 1.024
22 0.866
11 0.433
12 0.472
80 3.150
40 1.575
28 1.102
מ "0.02 mm
"0.0008 in
gold wire
6
4
0.236
0.157
מ 1 m
3,281 ft
7
0.276
מ 200 ЊC 392 ЊF ⅐ Coaxial
36 1.417
18 0.709
12 0.472
מ 20 0.787
10 0.394
140 5.512
70 2.756
45 1.772
מ "0.02 mm
"0.0008 in
gold wire
R25 mm
R0.984 in
140 5.512
100 3.937
47 1.850
1 m
3,281 ft
7
0.276
מ 300 ЊC 572 ЊF ⅐ Glass substrate detection
Fixed-focus reflective type
2 m
6.562 ft
W19 H27 D5
ן ן מ מ מ מ מ מ מ מ מ מ מ מ 0 to 15 0 to 0.591
0 to 10 0 to 0.394
1 to 8 0.039 to 0.315
2 to 6 0.079 to 0.236
W0.748 H1.063
ן "0.02 mm
"0.0008 in
gold wire
D0.197
ן R25 mm
R0.984 in
180 ЊC 356 ЊF ⅐ Glass substrate detection
Fixed-focus reflective type
W19 H27 D5
ן ן 2 m
6.562 ft
W0.748 H1.063
ן D0.197
ן 130 ЊC 266 ЊF
20 0.787
11 0.433
20 0.787
11 0.433
25 0.984
12 0.472
"0.02 mm
"0.0008 in
gold wire
R25 mm
R0.984 in
140 5.512
100 3.937
47 1.850
2 m
6.562 ft
7
0.276
מ 7
0.276
מ 8
0.315
מ 165 6.496
26 1.024
13 0.512
14 0.551
21 0.827
10 0.394
"0.02 mm
"0.0008 in
gold wire
R200 mm
R7.874 in
1 m
3,281 ft
7
4
0.276
0.157
מ 75 2.953
52 2.047
26 1.024
9
0.354
מ 6
0.236
מ Notes: 1) The sensing range is specified for white non-glossy paper [400
ן 400 mm 15.748ן 15.748 in (FD-H30-L32, FD-H18-L31: glass substrate 50ן 50 mm 1.969ן 1.969 in)] as the object. Notes: 2) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. In addition, the infrared
type is easily affected by humidity, so contact our office if using these sensors in environments with high humidity or where humidity levels can fluctuate.
Notes: 3) The minimum sensing object size is the value for red LED type at maximum sensitivity. Please contact our office for information on the minimum sensing
object size if using amplifiers other than red LED type. Also, note that the corresponding setting distance is different from the rated sensing distance.
The vacuum type fiber must be used with the following products as a set.
FT-J6: Fiber at atmospheric side (one pair set)
FV-BR1: Photo-terminal (one pair set)
Semi-standard fibers (Custom made per order)
The fiber cable length or sleeve length of the standard fibers can be modified at your request. Select the fiber cable length (symbol ꢀ ) or the sleeve length
(symbol f ) from the table below.
Correlation between sensing
range attenuation coefficient and
fiber cable length
Fiber cable length
(Unit: m ft)
ꢀ
Sleeve length
(Unit: cm in)
f
Basic model No.
FD-FM ꢀ
Type
The longer the fiber cable, the
shorter the sensing range.
Standard threaded
head (free-cut)
3
9.843,
4
13.123,
5
16.404,
10 32.808, 15 49.213, 20 65.617
2 6.562 (Note), 3 9.843, 4 13.123, 1 0.394, 2 0.787, 3 1.181, 4 1.575,
5 16.404, 10 32.808, 15 49.213, 5 1.969, 6 2.362, 7 2.756, 8 3.150,
With sleeve
FD-FM ꢀ -S f
20 65.617
9 3.543, 10 3.937, 11 4.331, 12 4.724
Small diameter
threaded head with
sleeve (free-cut)
1 0.394, 2 0.787, 3 1.181, 4 1.575,
5 1.969, 6 2.362, 7 2.756, 8 3.150,
9 3.543, 10 3.937, 11 4.331, 12 4.724
FD-NFM2-S f
200ЊC 392ЊF heat-resistant
2 6.562, 3 9.843
3 9.843
FD-H20-M ꢀ
350ЊC 662ЊF heat-resistant
FD-H35-M ꢀ
Note: The standard fiber has a 2 m 6.562 ft fiber cable length and a 4 cm 1.575 in or 9 cm 3.543 in sleeve length.
Accessories (attached with fibers)
Fiber cutter
Fiber attachment
• FX-CT2
• FX-AT2
• FX-AT3
• FX-AT4
(for "1 mm "0.039 in fiber)
• FX-AT5
(for "1.3 mm "0.051 in fiber)
• FX-AT6
(for fixed-length fiber)
for "2.2 mm
(
)
"0.087 in fiber
for "1 mm "0.039 in and "1.3 mm
"0.051 in mixed fiber
)
(
Notes: 1) Fiber cutter is not supplied as accessory along with FT-NB8, FT-N8, FD-N8 and FD-N4. Please order it separately.
Notes: 2) The fiber attachment is not attached with FT-N8/NB8/P80 and FD-N8/P80. The previous FX-AT10 attachment is attached with FD-N4.
80
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
FIBER OPTIONS
Lens (For thru-beam type fiber)
Designation Model No.
Description
Increases the sensing range by 5 times or
more.
Sensing range (mm) [Lens on both sides] (Note 2)
Mode
LONG
STD
FAST
S-D
Fiber
FT-B8
• Ambient temperature:
מ 60 to ם 350 ЊC מ 76 to ם 662 ЊF (
)
3,500 Note 3 2,500
2,000
2,500
2,500
1,600
2,000
2,500
1,500
2,500
1,500
900
1,000
1,300
1,300
800
1,000
1,100
900
1,100
750
500
(
)
)
)
(
)
)
FT-FM2
FT-T80
FT-R80
FT-W8
FT-P80
FT-P60
FT-P81X
FT-H35-M2
3,500 Note 3
3,500 Note 3
(
(
3,500 Note 3
3,500 Note 3
Expansion
(
3,500 Note 3 2,300
lens
(Note 1)
FX-LE1
(
)
3,500 Note 3 2,900
(
)
)
)
)
(
)
)
)
3,500 Note 3
3,500 Note 3
(
(
3,500 Note 3
3,500 Note 3
(
(
3,500 Note 3
3,500 Note 3
(
3,500 Note 3 2,000
(
)
FT-H20W-M1 1,600 Note 3 1,300
FT-H20W-M2 2,600 1,300
900
500
(
)
(
)
FT-H20-M1
1,600 Note 3
1,600 Note 3
1,100
900
Tremendously increases the sensing
range with large diameter lenses.
Sensing range (mm) [Lens on both sides] (Note 2)
Mode
LONG
3,500 Note 3
STD
3,500 Note 3
FAST
3,500 Note 3
S-D
3,500 Note 3
Fiber
FT-B8
• Ambient temperature:
מ 60 to ם 350 ЊC מ 76 to ם 662 ЊF (
)
)
)
)
)
)
)
)
)
)
)
)
(
)
)
)
)
)
)
)
)
)
)
)
)
(
)
)
)
)
)
)
)
)
)
(
)
)
)
)
)
)
)
)
(
(
(
(
FT-FM2
FT-R80
FT-W8
FT-P80
FT-P60
FT-P81X
FT-H35-M2
FT-H20W-M1 1,600 Note 3
FT-H20W-M2 3,500 Note 3
FT-H20-M1
FT-H13-FM2
3,500 Note 3
3,500 Note 3
3,500 Note 3
3,500 Note 3
(
(
(
(
3,500 Note 3
3,500 Note 3
3,500 Note 3
3,500 Note 3
Super-
expansion
lens
(
(
(
(
3,500 Note 3
3,500 Note 3
3,500 Note 3
3,500 Note 3
FX-LE2
(
(
(
(
3,500 Note 3
3,500 Note 3
3,500 Note 3
3,500 Note 3
(
(
(
(
3,500 Note 3
3,500 Note 3
3,500 Note 3
3,500 Note 3
(Note 1)
(
(
(
(
3,500 Note 3
3,500 Note 3
3,500 Note 3
3,500 Note 3
(
(
(
(
3,500 Note 3
3,500 Note 3
3,500 Note 3
3,500 Note 3
(
(
(
1,600 Note 3
1,600 Note 3
1,500
1,500
1,600 Note 3
(
(
3,500 Note 3
3,000
1,600 Note 3
(
(
(
)
)
(
)
)
1,600 Note 3
1,600 Note 3
(
(
(
(
3,500 Note 3
3,500 Note 3
3,500 Note 3
3,500 Note 3
Beam axis is bent by 90 Њ.
Sensing range (mm) [Lens on both sides] (Note 2)
Mode
• Ambient temperature:
מ 60 to ם 300 ЊC מ 76 to ם 572 ЊF LONG
STD
FAST
S-D
Fiber
FT-B8
1,100
1,200
1,200
900
1,200
650
1,200
550
310
530
600
600
450
600
300
600
280
140
140
280
400
440
440
330
440
200
440
200
100
100
200
186
210
210
160
210
130
200
90
FT-FM2
FT-T80
FT-W8
FT-P80
FT-P60
Side-
view
lens
FX-SV1
FV-LE1
FT-P81X
FT-H35-M2
FT-H20W-M1
FT-H20W-M2
FT-H20-M1
50
50
90
310
550
Sensing range increases by 15 times or
more.
Expansion
lens for
vacuum
fiber
Sensing range (mm) [Lens on both sides] (Note 2)
Mode
LONG
3,500 Note 3
STD
2,700
FAST
1,800
S-D
940
Fiber
• Ambient temperature:
מ 40 to ם 120 ЊC מ 40 to ם 248 ЊF (
)
FT-6V
FT-60V
2,800
1,450
1,000
490
(Note 1)
Notes: 1) Be careful when installing the thru-beam type fiber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is difficult.
Especially when installing a fiber with many cores (sharp bending fibers and heat-resistant glass fiber) please be sure to use it only after you have adjusted it sufficiently.
Notes: 2) The sensing ranges are the values for red LED type amplifier. Please contact our office for details on sensing ranges for other types of amplifiers.
Notes: 3) The fiber cable length practically limits the sensing range to 3.500 mm 137.795 in long (FT-H20W-M1 and FT-H20-M1: 1,600 mm 62.992 in).
Lens (For reflective type fiber)
Designation Model No.
Description
Pinpoint spot of "0.5 mm "0.020 in. Enables detection of minute objects or small marks.
Pinpoint
spot lens
FX-MR1
• Applicable fibers: FD-WG4, FD-G4
• Distance to focal point: 6
ע 1 mm 0.236 ע 0.039 in • Ambient temperature:
מ 40 to ם 70 ЊC מ 40 to ם 158 ЊF The spot diameter is adjustable from "0.7 mm Sensing range (Note 1)
"0.028 in to "2 mm "0.079 in according to
how much the fiber is screwed in.
Screw-in depth Distance to focal point
Spot diameter
"18.5 mm approx.
"27 mm approx.
"43 mm approx.
"0.7 mm
"1.2 mm
"2.0 mm
7 mm
12 mm
14 mm
FX-MR2
Zoom lens
• Applicable fibers: FD-WG4, FD-G4
•
Ambient temperature:
מ 40 to
ם 70 ЊC
מ 40 to
ם 158 ЊF • Accessory: MS-EX-3 (mounting bracket)
Extremely fine spot of "0.3 mm "0.012 in approx. Sensing range (Note 1)
achieved.
Fiber
FD-EG3
Distance to focal point
Spot diameter
"0.15 mm approx.
"0.2 mm approx.
"0.3 mm approx.
"0.5 mm approx.
•
Applicable fibers: FD-WG4, FD-G4, FD-EG1,FD-EG2,
7.5
ע 0.5 mm 7.5
ע 0.5 mm 7.5
ע 0.5 mm 7.5
ע 0.5 mm Finest spot
lens
FX-MR3
FD-EG2
FD-EG3, FD-G6X, FD-G6
FD-EG1
FD-WG4/G4/G6X/G6
•
Ambient temperature:
מ 40 to
ם 70 ЊC
מ 40 to
ם 158 ЊF Extremely fine spot of "0.1 mm "0.004 in approx. Sensing range (Note 1)
achieved.
Fiber
FD-EG3
Distance to focal point
Spot diameter
"0.1 mm approx.
"0.15 mm approx.
"0.2 mm approx.
"0.4 mm approx.
•
Applicable fibers: FD-WG4, FD-G4, FD-EG1,FD-EG2,
7
ע 0.5 mm 7
ע 0.5 mm 7
ע 0.5 mm 7
ע 0.5 mm Finest spot
lens
FX-MR6
FD-EG2
FD-EG3, FD-G6X, FD-G6
FD-EG1
FD-WG4/G4/G6X/G6
•
Ambient temperature:
מ 20 to
ם 60 ЊC
מ 4 to
ם 140 ЊF Sensing range (Note 1)
FX-MR2 is converted into a side-view type and
can be mounted in a very small space.
• Applicable fibers: FD-WG4, FD-G4
Zoom lens
Screw-in depth Distance to focal point
Spot diameter
"0.5 mm
"0.8 mm
Side-view
type
FX-MR5
8 mm
10 mm
14 mm
13 mm approx.
15 mm approx.
30 mm approx.
(
)
•
Ambient temperature:
מ 40 to
ם 70 ЊC
מ 40 to
ם 158 ЊF "3.0 mm
Note: The sensing ranges are the values when used in combination with red LED type amplifier. Please contact our office for details on sensing distances for other types of amplifier.
81
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
FIBER OPTIONS
Others
Protective tube
• FTP-Ⅺ
• FDP-Ⅺ
Designation
Model No.
Description
FT-B8
FT-N8
FT-P80
FT-P60
FTP-500 (0.5 m 1.640 ft)
FTP-1000 (1 m 3.281 ft)
FTP-1500 (1.5 m 4.921 ft)
FTP-N500 (0.5 m 1.640 ft)
FTP-N1000 (1 m 3.281 ft)
For
M4
thread
FT-NB8
FT-FM2
FT-FM2S
FT-FM2S4
FT-H13-FM2
Fiber bender
• FB-1
Protective tube
For thru-beam
FT-T80
FT-P40
FD-T40
FD-P40
(
)
type fiber
For
M3
thread
The protective
tube, made of
non-corrosive
stainless steel,
protects the
inner fiber cable
from any
FT-NFM2
FT-NFM2S
FT-NFM2S4
FTP-N1500 (1.5 m 4.921 ft
FDP-500 (0.5 m 1.640 ft)
FDP-1000 (1 m 3.281 ft)
)
e
FD-B8
FD-P80
FD-H13-FM2
Universal sensor mounting stand
• MS-AJ1-F
• MS-AJ2-F
Using the arm which enables adjustment
in the horizontal direction, sensing can
also be done from above an assembly line.
For
M6
thread
FD-FM2
FD-FM2S
FD-FM2S4
FD-N8
external forces.
Protective tube
For reflective
FDP-1500 (1.5 m 4.921 ft)
FDP-N500 (0.5 m 1.640 ft)
FDP-N1000 (1 m 3.281 ft)
FD-T80
FD-N4
FD-NFM2
FD-NFM2S
FD-NFM2S4
(
)
type fiber
For
M4
thread
FDP-N1500 (1.5 m 4.921 ft
)
The fiber bender bends the sleeve part of the fiber head at the
proper radius. (Note 1)
Fiber bender
FB-1
Universal sensor
mounting stand
(Note 2)
Horizontal mounting type
MS-AJ1-F
MS-AJ2-F
FX-CT2
Mounting stand assembly for fiber
(For M3, M4 or M6 threaded head fiber)
Vertical mounting type
The free-cut type fiber can be easily cut.
Accessory. Does not attach with the FT-N8/NB8 or the
FD-N8/N4. (Note 3)
Fiber cutter
FX-CT1
Attachment for fixed-
length fiber
This is the attachment for the fixed length fiber. (Accessory
)
FX-AT2
FX-AT3
Attachment for "2.2 mm
"0.087 in fiber
This is the attachment for the "2.2 mm "0.087 in fiber.
Note: The above figure is MS-AJ1-F.
The mounting base of MS-AJ2-F
has a different shape.
(Accessory. Does not attach with the FT-N8/NB8/P80 or the FD-N8/P80.)
Attachment for "1 mm
"0.039 in fiber
This is the attachment for the "1 mm "0.039 in fiber
(Accessory. Does not attach with the FD-N4.) (Note 4)
FX-AT4
FX-AT5
Fiber cutter
• FX-CT2
Attachment for "1.3 mm
"0.051 in fiber
This is the attachment for the "1.3 mm "0.051 in fiber (Accessory)
Attachment for "1 mm
"0.039 in / "1.3 mm
"0.051 in mixed fiber
This is the attachment for the "1 mm"0.039 in / "1.3 mm
"0.051 in mixed fiber. (Accessory)
FX-AT6
Notes: 1) Do not bend the sleeve part of any side-view type fiber or ultra-small diameter head type fiber.
Notes: 2) Refer to p.332l for details of the universal sensor mounting stand.
Notes: 3) A conventional FX-CT1 fiber cutter is attached with the FT-P80 and the FD-P80.
Notes: 4) The conventional FX-AT10 fiber attachment is attached with the FD-N4.
• FX-CT1
Fiber attachment
It’s possible to simultaneously cut two fibers to the same length
Each fiber (with some exceptions) has a newly developed two-in-one fiber attachment (FX-AT3/AT4/AT5/AT6) which enables two fibers to be cut simultaneously
to the same length with the new fiber cutter (FX-CT2). Also, since the fibers can be attached to the amplifier while being fixed in position in the two-in-one fiber
attachment, sensitivity changes resulting from variation in the amount of fiber insertion do not occur.
FX-AT2
FX-AT3
FX-AT4/AT5/AT6
82
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
SPECIFICATIONS
Amplifiers
NPN output
Blue LED Green LED Infrared LED Red LED
FX-301B FX-301G FX-301H FX-301P
PNP output
Type
Model No.
Red LED
Blue LED
Green LED Infrared LED
FX-301GP FX-301HP
Item
FX-301
FX-301BP
Supply voltage
12 to 24 V DC
ע 10 % Ripple P-P 10 % or less <Blue LED / Green LED type>
<Red LED / Infrared LED type>
Normal operation: 960 mW or less
Normal operation: 720 mW or less
Current consumption 40 mA or less at
Current consumption 30 mA or less at
24 V supply voltage
ECO mode: 430 mW or less
(
)
)
(
)
)
Power consumption
24 V supply voltage
ECO mode: 600 mW or less
Current consumption 25 mA or less at 24 V
Current consumption 18 mA or less at 24 V
supply voltage
(
(
supply voltage
PNP open-collector transistor
NPN open-collector transistor
• Maximum source current: 100 mA
Maximum sink current:100 mA
•
50 mA, if five, or more, amplifiers
are connected in cascade.
50 mA, if five, or more, amplifiers
are connected in cascade.
Applied voltage: 30 V DC or less (between output and 0 V)
Residual voltage: 1.5 V or less
(
)
(
)
Output
•
Applied voltage: 30 V DC or less (between output and
ם V) •
•
• Residual voltage: 1.5 V or less
at 100 mA (at 50 mA, if five, or more,
amplifiers are connected in cascade)
source current.
at 100 mA (at 50 mA, if five, or more,
amplifiers are connected in cascade)
sink current.
Utilization category
Output operation
DC-12 or DC-13
Selectable either Light-ON or Dark-ON, with jog switch
Incorporated
Short-circuit
protection
Response time
65 !s or less (ultra high speed), 150 !s or less (FAST), 250 !s or less [STD / S-D (Red LED type only)], 2 ms or less (LONG) selectable with jog switch
2-level teaching / Limit teaching / Manual adjustment / Full auto-teaching (excluding red LED type)
Orange LED (lights up when the output is ON)
Sensitivity setting
Operation indicator
Stability indicator
Green LED (lights up under stable light received condition or stable dark condition)
RUN: Green LED, TEACH ⅐ ADJ ⅐ L/D ON ⅐ TIMER ⅐ PRO:Yellow LED
4 digit red LED display
MODE indicator
Digital display
Incorporated
Fine sensitivity adjustment function
Timer function
Incorporated with variable ON-delay / OFF-delay / ONE SHOT timer, switchable either effective or ineffective. (timer period: 0.5 to 500 ms approx.)
Incorporated (Up to four sets of fiber heads can be mounted close together) (Note 1)
3 (Industrial environment)
Automatic interference prevention function
Pollution degree
מ 10 to ם 55 °C ם 14 to ם 131 °F If 4 to 7 units are connected in cascade:
מ 10 to ם 50 °C ם 14 to ם 122 °F, (
)
Ambient temperature
if 8 to 16 units are connected in cascade:
מ 10 to ם 45 °C ם 14 to ם 113 °F (No dew condensation or icing allowed),
Storage:
מ 20 to ם 70 °C מ 4 to ם 158 °F 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient humidity
Sunlight: 10,000?x at the light-receiving face, Incandescent light: 3,000?x at the light-receiving face
Ambient illuminance
Red LED type: EN 50081-2, EN 50082-2, EN 60947-5-2
Blue / green / infrared LED type: EN 60947-5-2
EMC
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Emitting element (modulated)
Material
1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 2)
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 2)
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each
Red LED
Blue LED
Green LED
Infrared LED
Red LED
Blue LED
Green LED
Infrared LED
Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, Switch: Acrylic
Connecting method
Cable extension
Connector (Note 3)
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
25 g approx.
Weight
Notes: 1) When the power supply is switched on, the emission timing are automatically set for interference prevention.
Notes: 2) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
Notes: 3) The cable for amplifier connection is not supplied as an accessory. Make sure to use the optional quick-connection cable given below.
Main cable (3-core): CN-73-C1 (cable length 1 m 3.281 ft), CN-73-C2 (cable length 2 m 6.562 ft), CN-73-C5 (cable length 5 m 16.404 ft)
Sub cable (1-core): CN-71-C1 (cable length 1 m 3.281 ft), CN-71-C2 (cable length 2 m 6.562 ft), CN-71-C5 (cable length 5 m 16.404 ft)
83
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
SPECIFICATIONS
Fibers
Type
Item
Standard
Flexible
Allowable bending radius
Bending durability
R25 mm R0.984 in or more [Sleeve of a head with sleeve:R10 mm R0.394 in or more (Note 1)]
R4 mm R0.157 in or more
1 million times or more (at R10 mm R0.394 in, FT-P40/P2 and FD-P40/P2: at R4 mm R0.157 in)
מ 40 to ם 70 °C מ 40 to ם 158 °F מ 40 to ם 70 °C מ 40 to ם 158 °F FT-SFM2SV2:
מ 20 to ם 70 °C
20 to
40 to
מ 4 to
60 °C
60 °C
ם 158 °F
4 to
40 to
Ambient temperature
(
מ FT-4Z08Ⅺto,ם FT6-P06°0C, Fמ T-4P0St1o, ם FD1-P4600°,FFD-P50: FT-V22, FD-SFM2SV2:
FT-V41, FD-V41, FT-V10:
מ ם מ ם 140 °F
)
(
)
מ ם מ ם 140 °F Ambient humidity
Fiber core
35 to 85%RH (No dew condensation or icing allowed)
Acrylic
Sheath
Polyethylene (FT-V22: Polyolefin)
Vinyl chloride (FT-PS1: Polyethylene, FD-P2: Vinyl chloride and Polyurethane)
i
Brass (Nickel plated)
Stainless steel (SUS)
FT/FD-P80, FT-P60: Brass (Nickel plated)
Case of FT-Z8Ⅺ: Polycarbonate
Lens of FT-Z8H/Z8E, Front film of FT-Z8: Polyester
FT-SFM2L/T80/SFM2/SNFM2/SFM2SV2/V22/V41,
FD-T80/T40/S80/SNFM2/SFM2SV2/V41 and Sleeve: Stainless steel (SUS)
FT-FM10L: ABS, Lens of FT-FM10L/SFM2L/V10: Acrylic
FT-V10: Stainless steel (SUS) and Polycarbonate
Fiber head
All fibers (except for FT-NB8/N8 and FD-N8/N4): 1 fiber attachment set
Free-cut type fibers (except for FT-NB8/N8 and FD-N8/N4): FX-CT2 (fiber cutter) 1 pc.
Threaded head fibers: Nuts 2 pcs. (thru-beam type: 4 pcs.) and toothed lock washer
1 pc. (thru-beam type: 2 pcs.)
All fibers: 1 fiber attachment set. (except for FT-P80 and FD-P80)
Free-cut type fibers: FX-CT2 (fiber cutter) 1 pc. (FT/FD-P80: FX-CT1 1 pc.)
Threaded head fibers: Nuts 2 pcs. (thru-beam type: 4 pcs.) and toothed lock
washer 1 pc. (thru-beam type: 2 pcs.), FT-Z8Ⅺ: 1 set of mounting screw
Accessories (Note 2)
Notes: 1) Sleeve part of side-view fiber cannot be bent.
Notes: 2) The five types of attached fiber attachments (FX-AT2/AT3/AT4/AT5/AT6) described in this catalog are for use only with the FX-301/311 series. Refer to
p.82 for details ‘FIBER OPTIONS’. Fiber attachment accessories are also supplied along with conventional amplifiers. Please contact our office for more
details on these accessories.
Type
Item
Sharp bending
Allowable bending radius
Ambient temperature
Ambient humidity
Fiber core
R1 mm R0.039 in or more (FD-WG4/WSG4: R2 mm R0.079 in or more, Sleeve of FD-W44: R10 mm R0.394 in or more)
מ 40 to ם 60 °C מ 40 to ם 140 °F (FT-WA30/WA8/WKV8: מ 40 to ם 55 °C מ 40 to ם 131 °F) 35 to 85 %RH (No dew condensation or icing allowed)
Acrylic
Sheath
Polyethylene
Stainless steel (SUS) (including sleeve)
FT-W8/W4, FD-W8/W44/WG4: Brass (Nickel plated)
Case of FT-WA30/WA8/WZ8Ⅺ, Lens of FT-WS8L and Resin part of FT-WKV8: Polycarbonate, Lens of FT-WA30: Norbornene resin
Lens of FT-WA8: Polyolefin, Lens of FT-WZ8H/WZ8E, Reflector of FT-WZ8E and Prism of FT-WKV8: Acrylic,
Reflector of FT-WZ8: Polycarbonate, FD-WL41: Heat-resistant ABS, Front film of FD-WL41: Polyester,
FD-WL42: Aluminum (Black ALMITE), Lens of FD-WKZ1: Optical lens
Fiber head
(
)
All fibers: 1 fiber attachment set and FX-CT2 (fiber cutter) 1 pc.
Threaded fibers: Nuts 2 pcs. (thru-beam type: 4 pcs.) and toothed lock washer 1 pc. (thru-beam type: 2 pcs.)
FT-WA30: 0.5
ן 32 mm 0.020ן 1.260 in seal type slit mask 2 pcs. FT-WA8: 0.5
ן 12 mm 0.020ן 0.472 in seal type slit mask 2 pcs. and 1ן 12 mm 0.039ן 0.472 in seal type slit mask 2 pcs. FT-WZ8Ⅺ: 1 set of mounting screw
Accessories (Note)
FD-WKZ1: mounting bracket 1 pc.
Note: The five types of attached fiber attachments (FX-AT2/AT3/AT4/AT5/AT6) described in this catalog are for use only with the FX-301/311 series. Refer to p.82 for details ‘FIBER
OPTIONS’. Fiber attachment accessories are also supplied along with conventional amplifiers. Please contact our office for more details on these accessories.
Type
Special use
Item
Wide beam
Array
Narrow beam
High precision
FT-A30/A8: R10 mm R0.394 in or more
FD-A15: R25 mm R0.984 in or more
R25 mm R0.984 in or more
(FT-KV1: R10 mm R0.394 in or more) FD-G4/G6/EG1: R25 mm R0.984 in or more
FD-EG2/EG3: R10 mm R0.394 in or more
Allowable bending radius
R25 mm R0.984 in or more
מ FD-G4:
FD-G6:
20 to
ם 60°C
מ 4 to
ם 140 °F
FT-A30, FD-A15:
מ 40 to
ם 60 °C
מ 40 to
158 °F
ם 140 °F מ 40 to ם 70 °C מ 40 to ם 60 °C מ 40 to
40 to
ם 70 °C
60 °C
מ 40 to 40 to
ם 158 °F 140 °F
Ambient temperature
(
)
FT-A8:
מ 40 to ם 70 °C
מ 40 to
ם מ 40 to ם 158 °F מ 40 to ם 140 °F מ ם מ ם Ambient humidity
Fiber core
35 to 85 %RH (No dew condensation or icing allowed)
Acrylic
Sheath
Polyethylene
Polyolefin (FD-G4/G6: Polyethylene)
Polycarbonate
Stainless steel (SUS), Polycarbonate
Brass (Nickel plated)
Lens of FT-A30, FD-A15: Norbornene resin
Brass (Nickel plated)
Lens: Norbornene resin
Fiber head
[FD-G6: Stainless steel (SUS)]
(
)
)
(
Lens of FT-A8: Polyolefin
Lens of FT-KV1: Polycarbonate, Prism of FT-KV8: Acrylic
All fibers: 1 fiber attachment set and
FX-CT2 (fiber cutter) 1 pc.
FT-A30: 0.5
ן 32 mm 0.020ן 1.260 in All fibers: 1 fiber attachment set
Free-cut type fibers: FX-CT2 (fiber cutter) 1 pc.
Threaded head fibers: Nuts 2 pcs. and toothed lock washer 1 pc.
FT-A8: 0s.5e
ן al type slit mask 2 pcs. 12 mm 0.020
ן 0.472 in Accessories (Note)
1
ן 12 mm 0.039
seal type slit mask
ן 2 0p.c4s7. 2anidn seal type slit mask 2 pcs.
Note: The five types of attached fiber attachments (FX-AT2/AT3/AT4/AT5/AT6) described in this catalog are for use only with the FX-301/311 series. Refer to p.82 for details ‘FIBER
OPTIONS’. Fiber attachment accessories are also supplied along with conventional amplifiers. Please contact our office for more details on these accessories.
84
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
SPECIFICATIONS
Fibers
Special use
Type
Item
Ultra-small diameter
Fixed-focus reflective
Tough flexible
FT-E12/E22: R5 mm R0.197 in or more (Note 1)
FD-E12: R10 mm R0.394 in or more (Note 1)
FD-E22/EN500S1/ENM1S1: R25 mm R0.984 in or more (Note 1)
R10 mm R0.394 in or more
(FD-L43: R4 mm R0.157 in or more)
Allowable bending radius
R10 mm R0.394 in or more
FT-E12/E22, FD-E22:
מ 40 to
ם 70 °C
מ 40 to
ם 4 to
ם 158 °F FD-L43: 0 to
ם 70 °C ם 32 to ם 158 °F 140 °F FD-L41/L42:
140 °F FD-L4: 40 to
מ 40 to
ם 60 °C מ 40 to ם 140 °F Ambient temperature
FD-E12:
מ 40 to
ם 60 °C
20 to
מ 40 to
מ 40 to
ם ם 60 °C
מ 40 to
ם 140 °F
(FD-P81X:
מ 40 to
ם 70 °C
מ 40 to
ם 158 °F) FD-EN500S1/ENM1S1:
מ ם 60 °C
מ ם מ 70 °C
מ 40 to
ם 158 °F Ambient humidity
Fiber core
35 to 85 %RH (No dew condensation or icing allowed)
Acrylic
Polyethylene [FT-P81X: Vinyl chloride,
Protective tube: Stainless steel (SUS)]
Sheath
Polyolefin
Polyethylene (FD-L42: Vinyl chloride)
i
FD-L43/L41: Heat-resistant ABS
FD-L4: ABS
M
Brass (Nickel plated)
[Sleeve: Stainless steel (SUS)]
FT-P81X, FD-P81X: Brass (Nickel plated)
FD-G6X: Stainless steel (SUS)
Fiber head
FD-L42: Aluminum (Black ALMITE)
Lens of FD-L43/L4: Acrylic
(
)
Front film of FD-L41: Polyester
All fibers: 1 fiber attachment set and
All fibers: 1 fiber attachment set , nuts 2
pcs. (thru-beam type: 4 pcs.) and toothed
All fibers: 1 fiber attachment set
Threaded head fibers: Nuts 2 pcs. and
toothed lock washer 1 pc.
FX-CT2 (fiber cutter) 1 pc.
FD-L4: M2.6 (length 12 mm 0.472 in) lock washer 1 pc. (thru-beam type: 2 pcs.)
screws with washers 2 pcs. and nuts 2 pcs. FD-G6X: FX-CT2 (fiber cutter) 1 pc.
Accessories (Note 2)
Notes: 1) Sleeve part cannot be bent.
Notes: 2) The five types of attached fiber attachments (FX-AT2/AT3/AT4/AT5/AT6) described in this catalog are for use only with the FX-301/311 series. Refer to p.82 for details ‘FIBER
OPTIONS’. Fiber attachment accessories are also supplied along with conventional amplifiers. Please contact our office for more details on these accessories.
Special use
Liquid level sensing
Type
Item
Model No.
FD-F8Y
FD-F4Ⅺ/F9Ⅺ
Protective tube: R40 mm R1.575 in or more
Fiber: R15 mm R0.591 in or more
R10 mm R0.394 in or more
Allowable bending radius
מ 40 to ם 100 °C מ 40 to ם 212 °F (Note 1) Ambient temperature
Ambient humidity
Fiber core
מ 40 to ם 125 °C מ 40 to ם 257 °F (Note 1) 35 to 85 %RH (No dew condensation or icing allowed)
Polycarbonate
Polyethylene
Sheath
Polypropylene
(Protective tube: Fluorine resin)
Polyetherimide
(Lens: Polycarbonate)
Fiber head
1 fiber attachment set, FX-CT2 (fiber cutter) 1pc.
Tying bands 4 pcs., anti-slip tubes 2 pcs.
1 fiber attachment set
FX-CT2 (fiber cutter) 1 pc.
Accessories (Note 2)
Notes: 1) With the liquid sensing fiber, make sure that the temperature of the liquid is also within the ambient temperature range.
Notes: 2) The five types of attached fiber attachments (FX-AT2/AT3/AT4/AT5/AT6) described in this catalog are for use only with the FX-301/311 series. Refer to p.82 for details ‘FIBER
OPTIONS’. Fiber attachment accessories are also supplied along with conventional amplifiers. Please contact our office for more details on these accessories.
Environment resistant
Type
Heat-resistant
Chemical-resistant
Vacuum
Item
350 °C 662 °F type 300°C 572°F type 200°C 392°F type 180°C 356°F type 130°C 266°F type
R25 mm R0.984 in or more
(FT-H20W-Ⅺ: R10 mm R0.394 in or more, Sleeve of a head with sleeve: R10 mm R0.394 in or more)
R30 mm R1.181 in or more R200 mm R7.874 in or more
(FT-Z802Y: R25 mm R0.984 in or more) (FT-60V: R30 mm R1.181 in or more)
Allowable bending radius
מ 60 to ם 350 °C מ 60 to ם 300 °C מ 60 to ם 200 °C מ 60 to ם 180 °C מ 40 to ם 115 °C מ 40 to ם 120 °C מ 60 to ם 130 °C מ 76 to ם 266 °F Ambient temperature
מ 76 to ם 662 °F מ 76 to ם 572 °F מ 76 to ם 392 °F מ 76 to ם 356 °F מ 40 tם o ם 239 °F מ 40 to ם 248 °F (Note 1, 2)
(Note 1, 2, 3) (Note 2)
(Note 2, 4)
(FT-Z802Y: 0 to
60 °C
ם 14 to ם 140 °F) Ambient humidity
Fiber core
35 to 85 %RH (No dew condensation or icing allowed)
Multi-component glass (Note 3)
Silicone
Silicone Acrylic
Quartz glass (Note 3)
Fluorine resin
Inside stainless steel
(SUS) spiral tube
FD-H20-21:
Sheath
Fluorine resin
Stainless steel (sus)
FT-H20W-Ⅺ:
Fluorine resin
Stainless steel (SUS)
Protective tube: Fluorine resin
Sheath: Polypropylene
(Sheath of FT-Z802Y: Fluorine resin)
Brass (Nickel plated)
FD-H20-21: Stainless steel (sus)
Fiber head
Stainless steel (SUS) Brass (Nickel plated)
Aluminum
FT-H20W-Ⅺ, FD-H18-L31 and FT-H13-FM2: 1 fiber attachment set
Free-cut type fibers: FX-CT2 (fiber cutter) 1 pc.
Threaded head fibers: Nuts 2 pcs. (thru-beam type: 4 pcs.) and toothed lock washer 1 pc. (thru-beam type: 2 pcs.)
Nuts 2 pcs. (thru-beam type: 4
pcs.) and toothed lock washer
1 pc. (thru-beam type: 2 pcs.)
Accessories (Note 5)
1 fiber attachment set
FX-CT2 (fiber cutter) 1 pc.
Notes: 1) If the fiber is used below
the allowable maximum temperature drops to
Notes: 2) The ambient temperature of heat-resistant 350 °C 662 °F type, 300 °C 572 °F type, 200 °C 392 °F type and 180 °C 356 °F type fibers are the value in dry
מ 30 °C מ 22 °F, its maximum resistable temperature drops to
ם 200° C
ם 392 °F. If the side-view lens FX-SV1 is put on the fiber head,
ם 300 °C 572 °F. (The ambient temperature range of FX-SV1 is from
ם מ 60 to 300 °C 76 to 572 °F.)
ם מ ם condition. In humid environment, the ambient temperature differs. (For a high humidity of 85 %RH, the ambient temperature is 0 to
Notes: 3) If the fiber material is quartz glass or multi-component glass, keep it away from vibration or impact.
ם 40 °C
ם 14 to 104 °F.) Notes: 4) The normal temperature for continuous usage or storage should be
מ 60 to ם 150 °C מ 76 to ם 302 °F. Notes: 5) The five types of attached fiber attachments (FX-AT2/AT3/AT4/AT5/AT6) described in this catalog are for use only with the FX-301/311 series. Refer to p.82 for details ‘FIBER
OPTIONS’. Fiber attachment accessories are also supplied along with conventional amplifiers. Please contact our office for more details on these accessories.
85
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
I/O CIRCUIT AND WIRING DIAGRAMS
NPN output type
I/O circuit diagram
Wiring diagram
Note: The quick-connection sub cable does not have brown lead wire
and blue lead wire.
Terminal arrangement diagram
Notes: 1) The quick-connection sub cable does not have
Notes: 2) 50 mA max., if five amplifiers, or more, are connected together.
ם V (brown) and 0 V (blue). Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : NPN output transistor
PNP output type
I/O circuit diagram
Wiring diagram
Note: The quick-connection sub cable does not have brown lead wire
and blue lead wire.
Terminal arrangement diagram
Notes: 1) The quick-connection sub cable does not have
Notes: 2) 50 mA max., if five amplifiers, or more, are connected together.
ם V (brown) and 0 V (blue). Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : PNP output transistor
86
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
SENSING CHARACTERISTICS (TYPICAL)
Parallel deviation
FT-FM10L
FT-SFM2L
FT-B8
FT-NB8
Thru-beam type
Thru-beam type
Thru-beam type
Thru-beam type
FT-FM2 FT-FM2S FT-FM2S4
FT-T80 FT-SFM2
FT-NFM2 FT-NFM2S
FT-N8
FT-R80
Thru-beam type
Thru-beam type
Thru-beam type
Thru-beam type
FT-NFM2S4 FT-SNFM2
L
FT-V10
FT-SFM2SV2
Thru-beam type
Thru-beam type
Horizontal direction
Vertical direction
Horizontal direction
Vertical direction
FT-V22
FT-V41
Thru-beam type
Thru-beam type
Horizontal direction
Vertical direction
Horizontal direction
Vertical direction
87
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
SENSING CHARACTERISTICS (TYPICAL)
Parallel deviation
FT-WA30
FT-WA8
FT-A8
Thru-beam type
Thru-beam type
FT-A30
Horizontal direction
Vertical direction
Horizontal direction
Vertical direction
L
FT-WZ8H
FZ-WZ8E
Thru-beam type
Thru-beam type
Vertical direction
Vertical direction
Horizontal direction
Horizontal direction
FT-WZ8
FT-WKV8
Thru-beam type
Thru-beam type
Vertical direction
Horizontal direction
FT-W8
FT-W4
FT-WS8L
FT-WS3
Thru-beam type
Thru-beam type
Thru-beam type
Thru-beam type
FT-WS8
FT-WS4
88
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
SENSING CHARACTERISTICS (TYPICAL)
Parallel deviation
FT-WV42
FT-Z8H
FT-Z8E
Thru-beam type
Thru-beam type
Thru-beam type
Horizontal direction
Vertical direction
FT-Z8
FT-P80
FT-P60
FT-P40
Thru-beam type
Thru-beam type
Thru-beam type
Thru-beam type
FT-P2
FT-PS1
FT-AFM2
Thru-beam type
Thru-beam type
Thru-beam type
Horizontal direction
Vertical direction
FT-AFM2E
FT-K8
Thru-beam type
Thru-beam type
Horizontal direction
Vertical direction
L
89
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
SENSING CHARACTERISTICS (TYPICAL)
Parallel deviation
FT-KV1
Thru-beam type
Horizontal direction
Vertical direction
FT-KV8
FT-E12
FT-E22
Thru-beam type
Thru-beam type
Thru-beam type
Horizontal direction
Vertical direction
FT-H35-M2
FT-H20W-M1
FT-H20W-M2
FT-P81X
FT-H20-M1
Thru-beam type
Thru-beam type
Thru-beam type
Thru-beam type
FT-H35-M2S6
FT-H13-FM2
FT-L8Y
FT-V8Y
Thru-beam type
Thru-beam type
Thru-beam type
Horizontal direction
Vertical direction
90
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
SENSING CHARACTERISTICS (TYPICAL)
Parallel deviation
FT-Z802Y
FT-6V
FT-60V
Thru-beam type
Thru-beam type
Thru-beam type
Parallel deviation with FX-LE1 (expansion lens) applied on both sides
FT-B8
FT-W8
FT-P80
FT-H35-M2
Thru-beam type
Thru-beam type
Thru-beam type
Thru-beam type
Thru-beam type
FT-H20W-M2
FT-H20-M1
Thru-beam type
Parallel deviation with FX-LE2 (super-expansion lens) applied on both sides
FT-B8
FT-W8
FT-P80
FT-H35-M2
Thru-beam type
Thru-beam type
Thru-beam type
Thru-beam type
91
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
SENSING CHARACTERISTICS (TYPICAL)
Parallel deviation with FX-LE2 (super-expansion lens) applied on both sides
FT-H20W-M2
FT-H20-M1
FT-H13-FM2
Thru-beam type
Thru-beam type
Thru-beam type
Parallel deviation with FX-SV1 (side-view lens) applied on both sides
FT-B8
FT-W8
Thru-beam type
Thru-beam type
Horizontal direction
Vertical direction
Horizontal direction
Vertical direction
FT-P80
FT-H35-M2
Thru-beam type
Thru-beam type
Horizontal direction
Vertical direction
Horizontal direction
Vertical direction
FT-H20W-M2
FT-H20-M1
Thru-beam type
Thru-beam type
Horizontal direction
Vertical direction
Horizontal direction
Vertical direction
92
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
SENSING CHARACTERISTICS (TYPICAL)
Sensing fields
FD-T40 FD-NFM2
FD-5
FD-FM2
FD-T80 FD-S80
FD-NFM2S FD-NFM2S4
FD-SNFM2
FD-B8
Reflective type
Reflective type
Reflective type
Reflective type
FD-FM2S FD-FM2S4
FD-N8
FD-N4
FD-R80
Reflective type
Reflective type
Reflective type
FD-SFM2SV2
FD-V41
Reflective type
Reflective type
Horizontal direction
Vertical direction
Horizontal direction
Vertical direction
FD-W8 FD-WT8
FD-WS8
FD-W44
FD-WT4
FD-WKZ1
Reflective type
Reflective type
Reflective type
Horizontal direction
Vertical direction
93
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
SENSING CHARACTERISTICS (TYPICAL)
Sensing fields
FD-WG4
FD-WV42
FD-P80
Reflective type
Reflective type
Reflective type
FD-WSG4
Horizontal direction
Vertical direction
FD-P60
FD-P50
FD-P40
FD-P2
Reflective type
Reflective type
Reflective type
Reflective type
FD-AFM2
FD-A15
Reflective type
Reflective type
FD-AFM2E
Horizontal direction
Vertical direction
Horizontal direction
Vertical direction
FD-G4
FD-G6
FD-EG1
FD-EG2
Reflective type
Reflective type
Reflective type
Reflective type
94
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
SENSING CHARACTERISTICS (TYPICAL)
Sensing fields
FD-EG3
FD-E12
FD-P81X
FD-H35-20S
FD-6V
FD-E22
FD-EN500S1
Reflective type
Reflective type
Reflective type
Reflective type
Reflective type
Reflective type
Reflective type
Reflective type
Reflective type
Reflective type
Reflective type
Reflective type
Reflective type
Reflective type
FD-H35-M2
FD-ENM1S1
FD-H20-M1
FD-H13-FM2
FD-G6X
FD-H35-M2S6
FD-H30-L32
FD-H18-L31
FD-H20-21
95
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
PRECAUTIONS FOR PROPER USE
Amplifier
Cascading amplifiers
This product is not a safety sensor. Its use is not
intended or designed to protect life and prevent body
injury or property damage from dangerous parts of
machinery. It is a normal object detection sensor.
•
•
Make sure that the power supply is off while cascading or removing the amplifier.
Make sure to check the allowable ambient temperature, as it
depends on the number of amplifiers connected in cascade.
In case two, or more, amplifiers are connected in cascade,
make sure to mount them on a DIN rail.
When connecting in cascade, mount the amplifiers close to each other, fitting
them between the optional end plates (MS-DIN-E) mounted at the two ends.
•
•
Mounting
How to mount the amplifier
1Fit the rear part of the amplifier on
• When the amplifiers move on the DIN rail depending on
the attaching condition, fitting them between the optional
end plates (MS-DIN-E) mounted at the two ends.
• Up to maximum 15 amplifiers can be added (total 16
amplifiers connected in cascade.)
• When connecting more than two amplifiers in cascade,
use the sub cable (CN-71-CⅪ) as the quick-connection
cable for the second amplifier onwards.
• Between the FX-301B(P)/G(P)/H(P) and the FX-301(P),
the setting status copy function via communication signal
cannot be used. If coupling these, please arrange
identical models one at a time.
a 35 mm 1.378 in width DIN rail.
2
Press down the front part of the
mounting section of the amplifier on
the 35 mm 1.378 in width DIN rail.
35 mm 1.378 in width DIN rail
How to remove the amplifier
1Push the amplifier forward.
2Lift up the front part of the
amplifier to remove it.
Note: Take care that if the front part is lifted without pushing the amplifier
forward, the hook on the rear portion of the mounting section is likely to
break.
How to connect the fiber cables
Cascading method
1
2
Snap the fiber lock lever down.
Insert fiber cables slowly into the
inlets until they stop. (Note 1)
1Mount the amplifiers, one by
one, on the 35 mm1.378 in
width DIN rail.
3Return the fiber lock lever
to the original position, till
it stops.
Notes: 1) In case the fiber cables are not inserted to a position where they
stop, the sensing range reduces.
Notes: 2) With the coaxial reflective type fiber, such as, FD-G4 or FD-FM2,
insert the single-core fiber cable into the beam-emitting inlet and
the multi-core fiber cable into the beam-receiving inlet. If they are
inserted in reverse, the sensing accuracy will deteriorate.
1
2
(For details, refer to ‘Mounting’.)
Slide the sub units next to the
main unit, and connect the
quick-connection cables.
3
Mount the optional end plates
(MS-DIN-E) at both the ends to
hold the amplifiers between
their flat sides.
4Tighten the screws to fix the
Connection
end plates (MS-DIN-E).
• Make sure that the power supply is off while connecting
or disconnecting the quick-connection cable.
Dismantling
1Loosen the screws of the end
Connection method
plates (MS-DIN-E).
2
3
Remove the end plates (MS-DIN-E).
Slide the sub units and remove
them one by one.
1Holding the connector of the
quick-connection cable, align its
projection with the groove at
the top portion of the amplifier
connector.
3
(For details, refer to ‘Mounting’.)
2Insert the connector till a click
is felt.
Operation procedure
• When the power supply is switched on, communication
self-check is carried out and normal condition is
displayed [MODE indicator / RUN (green) lights up and
the digital display shows incident light intensity].
Disconnection method
1
Pressing the projection at the top of
the quick-connection cable connector,
pull out the connector.
•
When MODE key is pressed, the mode changes as per the diagram below.
Note: Take care that it the connector is pulled out
without pressing the projection, the projection
may break. Do not use a quick-connection
cable whose projection has broken.
Note: Further, do not pull by holding the cable, as
this can cause a cable-break.
Part description
When jog switch is pressed, the setting is confirmed.
When MODE key is pressed for 2 sec., or more, the sensor returns to the RUN mode.
Cancellation is possible by pressing MODE key during setting.
96
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
PRECAUTIONS FOR PROPER USE
Amplifier
Teaching
In case of limit teaching
•
The threshold values can be set by 2-level teaching, limit teaching or full-
auto teaching, when the MODE indicator / TEACH (yellow) lights up.
•
This is the method of setting the threshold value by teaching
only the object absent condition (stable incident light
condition). This is used for detection in the presence of a
background body or for detection of small objects.
In case of 2-level teaching
•
This is the method of setting the threshold value by teaching two levels, corresponding to
the object present and object absent conditions. Normally, setting is done by this method.
Step
Description
Display
Step
Description
Display
Set the fiber within the sensing
range.
Press MODE key to light up
MODE indicator / TEACH
(yellow).
Set the fiber within the sensing
range.
Press MODE key to light up
MODE indicator / TEACH
(yellow).
1
1
Press jog switch in the object absent condition.
If the teaching is accepted, the read incident light
intensity blinks in the display.
Press jog switch in the object present condition.
If the teaching is accepted, the read incident light intensity blinks in the digital display.
Thru-beam type
Reflective type
Thru-beam type
Reflective type
2
3
2
MODE indicator / TEACH (yellow) blinks.
Press jog switch in the object absent condition.
MODE indicator / TEACH (yellow) blinks.
Turn jog switch to the ‘
ם ’ side or ‘מ ’ side. Thru-beam type
Reflective type
3
If jog switch is turned to the ‘
ם ’ side, ‘ ’ scrolls
(twice) the display from right to left, and the threshold
level is shifted to a value approx. 15 %
higher (lower sensitivity) than that set
at 2. (Note 1)
If the teaching is accepted, the read incident light intensity
blinks in the digital display and the threshold value is set
at the mid-value between the incident light intensities in
the object present and the object absent conditions. After
this, the judgment on the stability of sensing is displayed.
This is used in case of reflective type fibers.
If jog switch is turned to the ‘
מ ’ side, ‘ ’ scrolls
(twice) the display from left to right, and the threshold
level is shifted to a value approx. 15 %
lower (higher sensitivity) than that set
at 2. (Note 1)
4
4
• In case stable sensing is possible: ‘
Stability indicator (green) blinks.
’ is displayed.
This is used in case of thru-beam type
fibers.
• In case stable sensing is not possible: ‘
Stability indicator (green) is off.
’ blinks.
5
6
The threshold value is displayed.
‘
’ blinks in the digital display.
The incident light intensity appears in the digital
display and the setting is complete.
7
Note: Do not move or bend the fiber cable after the sensitivity setting. Detection may become unstable.
After this, the judgment on whether the setting shift
amount can be shifted or not is displayed.
FX-301B(P)/G(P)/H(P) only
In case of full auto-teaching
5
• In case shifting is possible: ‘
• In case shifting is not possible: ‘
’ blinks.
’ blinks.
•
Full auto-teaching is used when it is desired to set the threshold value
without stopping the assembly line, with the object in the moving condition.
6
7
The threshold value is displayed.
Step
Description
Display
‘
’ blinks in the digital display.
Set the fiber within the sensing
range.
Press MODE key to light up
MODE indicator / TEACH
(yellow).
The incident light intensity appears in the digital
display and the setting is complete.
8
1
Notes: 1) The approx. 15% amount of shift is the initial value. The amount of
shift can be changed in the PRO mode from approx. 5 to 80 %
(5 % step). Refer to the ‘Fiber Sensor Guide Book’ or ‘SUNX fiber
pertaining to setting instructions.
Notes: 2) Do not move or bend the fiber cable after the sensitivity setting.
Detection may become unstable.
Press the jog switch continuously for 0.5 sec. or more
with the object moving on the assembly line. (The
incident light intensity is displayed during sampling.)
2
3
‘
’ is displayed on the digital display. Release the
jog switch when the object has passed.
If the teaching is accepted, the read incident light intensity
blinks in the digital display and the threshold value is set
at the mid-value between the incident light intensities in
the object present and the object absent conditions. After
this, the judgment on the stability of sensing is displayed.
4
• In case stable sensing is possible: ‘
Stability indicator (green) blinks.
• In case stable sensing is not possible: ‘
Stability indicator (green) is off.
’ is displayed.
’ blinks.
Notes: 1) The threshold value’s shift amount can be selected in PRO mode.
sensor.com) for more details pertaining to setting instructions.
(Increments of 5 % between –45 and 45 % for setting possible. 0 %
default.)
5
6
The threshold value is displayed.
‘
’ blinks in the digital display.
The incident light intensity appears in the digital
display and the setting is complete.
Notes: 2) Do not move or bend the fiber cable after the sensitivity setting.
Detection may become unstable.
7
97
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
PRECAUTIONS FOR PROPER USE
Amplifier
Threshold value fine adjustment
Key-lock function
• With the FX-301B(P)/G(P)/H(P), if jog switch and MODE
key are pressed for more than 3 sec. at the same time in
‘RUN’ mode condition, the key operations are locked, and
only the threshold value confirmation function or the adjust
function (valid only when the adjust lock function is
canceled) is valid.
Step
Description
Display
Press MODE key to light up
MODE indicator / ADJ (yellow).
1
• To cancel the lock function, press both the keys for more
than 3 sec. once again.
In case the threshold value is to be increased
(sensitivity to be reduced), turn the jog
switch to the ‘
ם ’ side to increase the threshold value slowly.
If the jog switch is turned continuously
to the ‘
ם ’ side, the threshold value increases rapidly.
In case the threshold value is to be
decreased (sensitivity to be
increased), turn the jog switch to the
‘
מ ’ side to decrease the threshold value slowly. If the jog switch is turned continuously to
the ‘
מ ’ side, the threshold value decreases rapidly. Wiring
• Make sure that the power supply is off while wiring.
• Verify that the supply voltage variation is within the rating.
2
or
• Take care that if a voltage exceeding the rated range is
applied, or if an AC power supply is directly connected, the
sensor may get burnt or damaged.
• If power is supplied from a commercial switching regulator,
ensure that the frame ground (F.G.) terminal of the power
supply is connected to an actual ground.
When jog switch is pressed,
the threshold value is confirmed.
2
• In case noise generating equipment (switching regulator,
inverter motor, etc.) is used in the vicinity of this product,
connect the frame ground (F.G.) terminal of the equipment
to an actual ground.
Output operation setting
• Take care that short-circuit or wrong wiring of the load may
burn or damage the sensor.
Step
Description
Display
Press MODE key to light up
MODE indicator / L/D ON
(yellow).
• Do not run the wires together with high-voltage lines or
power lines or put them in the same raceway. This can
cause malfunction due to induction.
1
Displays
present setting
• Ensure that an isolation transformer is utilized for the DC
power supply. If an auto transformer is utilized, the main
amplifier or power supply may be damaged.
If the jog switch is turn to the
‘
ם ’ or ‘מ ’ direction, the output operation setting will change.
Light state
2
3
• Make sure to use the optional quick-connection cable for
the connection of the amplifier. Extension up to total
100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
However, in order to reduce noise, make the wiring as
short as possible.
Dark state
When jog switch is pressed,
the threshold value is confirmed.
Displays
selected setting
Others
• Do not use during the initial transient time (0.5 sec.
approx.) after the power supply is switched on.
Timer operation setting
• The setting for whether the timer is used or not can be
done when MODE indicator / TIMER (yellow) lights up.
• Take care that the sensor is not directly exposed to
fluorescent light from a rapid-starter lamp or a high
frequency lighting device, as it may affect the sensing
performance.
• 10 ms OFF-delay (initial value) timer is automatically set
when the timer is set to be used.
• This sensor is suitable for indoor use only.
• Further, an OFF-delay (initial value) which is useful when
the response of the connected device is slow, etc., an ON-
delay which is useful to detect only objects taking a long
time to travel, and ONE SHOT, which is useful when the
input specifications of the connected device require a
signal of a fixed width, are possible with the FX-301
series. Refer to the ‘Fiber Sensor Guide Book’ or ‘SUNX
the setting method of the OFF-delay, ON-delay and ONE
SHOT timer intervals.
• Avoid dust, dirt, and steam.
• Take care that the product does not come in direct contact
with water, oil, grease, or organic solvents, such as,
thinner, etc.
• This sensor cannot be used in an environment containing
inflammable or explosive gasses.
• Never disassemble or modify the sensor.
(Note)
Note: The OFF-delay timer interval set in the PRO mode is displayed.
Refer to the ‘Fiber Sensor Guide Book’ or ‘SUNX fiber sensor home
98
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
PRECAUTIONS FOR PROPER USE
Amplifier
PRO mode
• Refer to the ‘Fiber Sensor Guide Book’ for more details
pertaining to the PRO mode settings and procedures.
• The above can also be download from ‘SUNX fiber sensor
homepage’ (http://www.fiber-sensor.com)
• PRO settings can be done when MODE indicator / PRO
(yellow) lights up.
Table for PRO mode settings
99
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
PRECAUTIONS FOR PROPER USE
Fiber
Mounting
Mounting array fiber
• The tightening torque must not exceed the values given
below.
• Using M3 screws, the tightening
torque should be 0.58 N⅐m or less.
Mounting with a nut (threaded head type)
Tightening torque
M3
M4
0.39 N·m
0.58 N·m
350 °C 662 °F heat-resistant fiber and
FT-H20W-MⅪ: 0.98 N⅐m,
FD-H35-20S: 0.58 N⅐m
(
)
Mounting FD-L4
0.98 N·m
350 °C 662 °F heat-resistant
fiber: 1.96 N⅐m
M5
M6
• Using M2.6 (length
12 mm 0.472 in)
screws with washers
(accessory), the
tightening torque
should be 0.3 N⅐ m
or less.
(
)
M14
1.47 N⅐m
Mounting with a set screw
Tightening torque: 0.29 N⅐m or less
Mounting FD-WL41 / FD-L41 and FD-WL42 / FD-L42
FT-SFM2L: 0.19 N⅐m
FT-H20W-MⅪ: 0.49 N⅐m
(
)
• Using M3 counter-
<FD-WL41 / FD-L41>
sunk head screws,
the tightening torque
should be 0.3 N⅐ m
or less.
• Fibers for which the tightening section has been specified
should be fixed at ?mm from the tightening section tip.
However, for FT-K8, FT-KV8, FT-WKV8 and FT-V10 ‘?’
(
)
indicates the range over which tightening cannot be done.
? (mm in) Tightening torque
<FD-WL42 / FD-L42>
FT-PS1
FD-E12
3 0.118
0.1 N⅐m
4 0.157
(Note 1)
0.29 N⅐m
FT-V22
FT-41, FD-V41
FT-SFM2SV2
<FT-K8, FT-KV8, FT-WKV8, FT-V10>
10 0.394
0.19 N⅐m
FD-EG1
10 0.394
15 0.591
7 0.276
0.29 N⅐m
0.29 N⅐m
0.34 N⅐m
Mounting FD-L43
FT-WV42
FD-WV42
• Using M3 counter-
sunk head screws,
the tightening torque
should be 0.3 N⅐ m
or less.
FD-SFM2SV2
FT-KV8, FT-WKV8
FT-V10
13 0.512
12 0.472
0.3 N⅐m
FT-K8
Notes 1): Excluding the sleeve.
Notes 2): When installing, make sure to use
screws smaller than the fiber
diameter.
100
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
PRECAUTIONS FOR PROPER USE
Fiber
Mounting FT-Z8Ⅺ and FT-WZ8Ⅺ
<FT-Z8H / FT-WZ8H (Top sensing type)>
In case of tapping the mounting section
• Mount the fiber head by using the enclosed set of screws.
The tightening torque should be 0.15 N⅐m or less
• If the fiber head is mounted in places subject to vibrations
or shocks, use a screw-locking adhesive, etc.
• Mount each fiber head as given below.
<FT-Z8 / FT-WZ8 (Front sensing type)>
In case of tapping the mounting section
In case of using attached screw and nut
In case of using attached screw and nut
Mounting FT-Z802Y
• Using M3 pan head
screws, the tightening
torque should be
0.3 N⅐m or less.
<FT-Z8E / FT-WZ8E (Side sensing type)>
In case of tapping the mounting section
Mounting FD-WKZ1
<If not using the attached mounting brackets>
• Use M3 or less set screws (cup point), and affix the head
within 15 mm 0.591 in from the tip of the fiber head. Do
not exceed a torque of 0.3 N⅐m when tightening.
In case of using attached screw and nut
<If using the attached mounting brackets>
• The head can be affixed even without using the set
screws.
• If using the set screws, use M3 set screws (cup point) to
affix and do not exceed a torque of 0.05 N⅐ m when
tightening.
Mounting FD-A15
• Using M3 screws, the tightening torque should be 0.3 N⅐m
or less.
Mounting FD-H30-L32 / FD-H18-L31
• Using M3 screws, the tightening torque should be 3 N⅐m
or less.
101
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
PRECAUTIONS FOR PROPER USE.
Fiber
Connection with reflective coaxial type fiber
Narrow beam type fiber mounting
• With reflective coaxial type fiber, insert the center fiber
cable (single-core) into the beam-emitting inlet and the
outer fiber cable (multi-core) into the beam-receiving inlet.
•
Take care that, since the aperture angle of this product is very
narrow, the beam may not be received depending upon the setting.
At the time of installation, determine a reference plane, as shown in
the figure below, and taking sufficient care against beam
misalignment or tilt, install the emitting and receiving fibers so that
they are parallel.
FD-H35-M2 or FD-H20-M1 is marked ‘P’ on the beam-
emitting fiber cable and ‘D’ on the beam-receiving fiber cable.
FD-WG4, FD-WSG4 and FD-G4, FD-G6, FD-G6X are
composed of beam-emitting and beam-receiving fiber
cables that are different in diameter.
<FT-K8>
FD-G500, FD-EG1, FD-EG2, FD-EG3, FD-E22,
FD-H20-21 and FD-ENM1S1 are marked P on the
beam-emitting fiber cable.
<FT-KV8 / FT-WKV8>
Notes: 1) In case the fiber cables are not inserted to a position where they
stop, the sensing range reduces.
Notes: 2) Before connecting fiber cables to the amplifier, mount the fiber
attachments on their ends.
Fiber cable bending radius
•
If the fiber cable is bent at a smaller bending radius than allowable
bending radius, the sensing range decreases due to beam attenuation.
Thru-beam type wide beam fiber mounting
• Take care that, since the aperture angle of this product is
very narrow, the beam may not be received depending
upon the setting.
At the time of installation, determine a reference plane, as
shown in the figure below, and taking sufficient care
against beam misalignment or tilt, install the beam-
emitting and receiving fibers so that they are parallel.
For a allowable bending radius of 25 mm (0.984 in)
Note: Please note that the 350 °C 662 °F
heat-resistant fibers, vacuum-
resistant and chemical-resistant
fibers cannot bend less than the
allowable bending radius.
How to bend sleeve
• The bending radius must be R10 mm R0.394 in or more.
Please bend gradually using the fiber bender (FB-1) or a
round bar of "20 mm "0.787 in or more.
• Install the fiber using M3
countersunk head screws.
The tightening torque should
be 0.3 N⅐m or less.
Note: Do not bend the sleeve of side-view type, narrow beam type, narrow-
view type and ultra-small diameter type fiber.
Further, when using the fiber
at places having intense
vibrations, use a screw-
locking adhesive, etc.
Use of heat-resistant type fiber
• Use by keeping 150 mm 5.906 in, or more, of the heat-
resistant fiber cable part at normal temperature.
• If mineral oil or solvent containing mineral oil component
adheres to the sensing surface, the lens may be
deformed. Take sufficient care to handle them.
Method of fixing fiber cable
•
If fixing the fiber cable in position, make sure that it is set in
a manner as shown below, so that no load is applied on the
fiber. (Excluding FT-H35-M2, FT-H35-M2S6, FD-H35-M2
and FD-H35-M2S6)
• Protect the amplifier from heat radiation or hot air.
• With the 350 ЊC 662 °F heat-resistant type fiber, the
surface of the fiber head or the spiral may be discolored
by heat. However, this does not affect its performance.
102
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
PRECAUTIONS FOR PROPER USE.
Fiber
Fiber attachments (FX-ATⅪ)
Mounting
<FX-AT2>
Product outline
1
Mount the plug part of the fiber cables in FX-AT2, as shown
in the figure below. (The resin plug
•
When the beam-emitting and beam-receiving fiber cables are
inserted into the fiber sensor amplifier (FX-301/302/303/311
series etc.), the enclosed fiber attachment
(FX-AT2/AT3/AT4/AT5/AT6) facilitates insertion of the fiber
cables and reduces the possibility of incorrect fiber cable
insertion.
has a groove to hold it in place.)
2Connect the fiber cables, in
condition 1, to the fiber sensor
amplifier.
<FX-AT3>
Cautions
1Confirm that the fiber lock button
of FX-AT3 is in unlock side.
2Insert the fiber cables one by one,
in condition 1.
•
Take care that FX-AT2, FX-AT3, FX-AT4, FX-AT5 and FX-AT6
cannot be used with fiber sensor amplifiers having a pitch,
between the beam-emitting and the beam-receiving fiber
cables, other than 7 mm 0.276 in. In case of fiber sensor
amplifiers having a pitch other than 7 mm 0.276 in, please use
attachments FX-AT10 or FX-AT13. (accessory)
3
After inserting, press down the fiber
lock button. The fiber cables are fixed
at the desired position. (In order to
unlock the fiber cables, press the fiber
lock button towards unlock direction
from the opposite side.)
Component description
<FX-AT2>
Attachment for fixed-length fiber: orange
4
5
Insert the fiber cables into the
holes for 2.2 mm 0.087 in fiber
"
"
cables of the fiber cutter (FX-CT2)
from the direction shown in the
figure right.
Cut both fiber cables simultaneously. (At this time, place
the attachment without any gap against the fiber cutter.
The fiber cables will be cut at a position approx. 10.5 mm
0.413 in from the tip of the fiber cable.)
<FX-AT3>
Attachment for 2.2 mm 0.087 in fiber: clear
"
"
orange
6After cutting, connect the fiber cables to the fiber sensor
<FX-AT4>
amplifier immediately.
Attachment for 1 mm 0.039 in fiber: black
"
"
<FX-AT4, FX-AT5, FX-AT6>
1Mount the holders on the gland lightly.
Notes: 1) If both long holders and short holders are enclosed with the
fiber, use the short holders.
1Notes: 2) In case of FX-AT6, match the colors of the holders and the
<FX-AT5>
Attachment for 1.3 mm 0.051 in fiber: gray
gland. The black color is for 1.0 mm 0.039 in fiber cable and
"
"
"
"
the gray color is for 1.3 mm 0.051 in fiber cable.
"
"
2Insert the fiber cables into the holders, in condition 1.
3
4
Tighten the holders to fix the fiber cables at the desired length.
Insert the fiber cables, in
condition
3
, into the holes for
1.0 mm 0.039 in or 1.3 mm
"
"
"
<FX-AT6>
0.051 in fiber cables of the fiber
"
Attachment for 1 mm / 1.3 mm 0.039 in /
"
"
"
cutter (FX-CT2) from direction
shown in the figure right.
Cut both fiber cables simultaneously.
(At this time, insert the attachment to
a position at which it stops. The fiber
cables will be cut at a position approx. 0.5 mm 0.020 in from the holder.)
0.051 in mixed fiber
"
for 1 mm 0.039 in fiber: black,
"
"
5
(
)
for 1.3 mm 0.051 in fiber: gray
"
"
<FX-AT10>
Attachment for 1 mm 0.039 in fiber: black
"
"
6After cutting, insert the fiber cables to the fiber sensor
amplifier immediately.
<FX-AT10, FX-AT13>
1
Thread the fiber cable through the
gland and holder separately, and
screw the gland into the holder
clockwise.
This is enclosed by FX-AT4.
2
Insert the fiber cables one by one
into the holes for 1.0 mm 0.039 in
<FX-AT13>
Attachment for 1.3 mm 0.051 in fiber: gray
"
"
"
"
or 1.3 mm 0.051 in fiber cable of
"
"
the fiber cutter (FX-CT2) from the
direction shown in the figure right. (At
this time, insert the attachment to a
position at which it stops. The fibers
will be cut at a position approx. 0.5
mm 0.020 in from the holder.)
This is enclosed by FX-AT5.
103
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
PRECAUTIONS FOR PROPER USE.
Fiber
Fiber cutter (FX-CT2)
Vacuum type fiber
Configuration
•
To cut the fiber cables, insert them from the direction shown below.
(Fiber cable insertion direction)
How to use fiber cutter (FX-CT2)
A
1Slide part
of the fiber cutter fully upward till it stops.
2Insert the fiber cables, mounted in the attachment, till
they stop.
Take care that there are separate fiber insertion cable
holes for 2.2 mm 0.087 in and 1.0 mm 0.039 in or
"
"
"
"
(
)
1.3 mm 0.051 in fiber cables.
"
"
A
3Slide part
of the fiber cutter down to cut the fibers.
Leakage: 1.33
ן 10–10 Pa⅐m3/sec. [He] or less Mounting
1Make two holes on the vac-
uum tank wall (chamber
wall or flange).
Note: The hole diameter must be from
"5.5 to "6.0 mm "0.217 to
"0.236 in.
Notes: 1) The fiber cables should be cut in one stroke.
Notes: 2) Once a fiber cable is cut off at a hole, do not use the hole again. If
used, it degrades the cut surface quality and the detectability may
deteriorate.
Notes: 3) The blade cannot be replaced. Please purchase an additional fiber
cutter, if required.
Notes: 4) Note that the sensing range may be reduced by up to 20 %
depending on the cut condition. Hence, decide the setting distance
by taking sufficient margin.
2Mount the FV-BR1 photo-terminal on the vacuum tank
wall.
Notes: 1) The attached O-ring must be mounted.
Notes: 2) The O-ring must be used at the atmospheric side.
Notes: 3) The tightening torque should be 0.58 N⅐m or less.
Seal type slit mask for FT-WA30/A30, FT-WA8/A8
• Two types of slit masks are enclosed. (one type for
FT-A30 and FT-WA30) Apply the enclosed slit mask when
detecting small objects or as measures not to saturate the
emitted light amount for short-range sensing.
However, the sensing range is reduced when the slit mask
is mounted.
As the slit mask is seal type, stick it by aligning the
projection of the slit mask with the upper portion of the
fiber head, as shown in the figure below.
3Mount the FT-J6 atmospheric side fibers on the
atmospheric side of the FV-BR1 photo-terminals.
Notes: 1) The fixing nuts must be tightened securely. If not, the sensing
range may decrease.
Notes: 2) The tightening torque should be 0.58 N⅐m or less.
Slit masks
Mounting
4Mount the vacuum type fibers on the vacuum side of the
FV-BR1 photo-terminals.
Notes: 1) The fixings rings of the vacuum type fibers must be tightened
securely. If not, the sensing range may decrease.
Notes: 2) The tightening torque should be 0.58 N⅐m or less.
5Fix the fiber head of the vacuum type fiber.
Note: The maximum tightening torque should be as given below.
Tightening torque
0.29 N⅐m
M2.6
Sensing range when mounting slit mask [with FX-301(P)]
M4
M6
0.58 N⅐m
FT-WA30/A30: 2,500 mm 98.425 in (LONG) / 1,000 mm 39.370 in
(STD) / 600 mm 23.622 in (FAST) / 200 mm 7.874 in
(S-D)
FT-WA8/A8: 400 mm 15.748 in (LONG) / 200 mm 7.874 in (STD) / 140 mm
5.512 in (FAST) / 70 mm 2.756 in (S-D) (0.5
ן 12 mm
0.020
ן 0.472 in slit mask) FT-WA8/A8: 800 mm 31.496 in (LONG) / 400 mm 15.748 in (STD) /
280 mm 11.024 in (FAST) / 140 mm 5.512 in (S-D)
(1
ן 12 mm 0.039ן 0.472 in slit mask) 104
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
PRECAUTIONS FOR PROPER USE.
Fiber
FT-L8Y/V8Y chemical-resistant type fiber
• Do not use it in the following chemicals:
Dissolved alkali metals (Natrium, Potassium or Lithium),
Fluorine gas (F2), CIF3, OF2 (including gaseous state).
• The beam axis mark is indicated on the side-view fiber.
Perform the beam alignment with the beam axis marks, on
the receiver and the emitter, facing each other.
Mounting
• Use a commercial Fluorine resin
joint to mount the fiber.
•
The bending radius of the protective
jacket should be R30 mm 1.181 in
or more. It will be damaged under
the value.
• The bending radius of the bear
fiber should be R25 mm R0.984 in
or more. The sensing range will be
shortened under the value.
• Do not subject the fiber under tension.
• Although the chemical-resistant type fiber is rated for use
up to
ם 115 °C ם 239 °F, place 100 mm 3.937 in or more of the fiber in the normal temperature area to protect the
amplifier.
FD-F8Y liquid level sensing fiber
Mounting
• Use a commercially available fluorine resin joint, etc., to
install FD-F8Y.
Cautions
• Take care that unclear liquid may not be sensed stably.
• Take care that the tube may stretch by maximum 2 % of
the total length if it is used at a high temperature.
• Do not scratch the fiber jacket while cutting the fluorine
resin tube.
105
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
PRECAUTIONS FOR PROPER USE.
Fiber
FD-F4Ⅺ and FD-F9Ⅺ liquid level sensing fiber
Cautions
Mounting
• Liquid in a pipe which is not transparent cannot be sensed
correctly.
• Mount the fiber head on a pipe with the attached tying
bands and anti-slip tubes as shown in the figure below.
Make sure that the release lever is retracted (position as in
the fig.) before mounting.
Fasten two tying bands, as shown, and cut off the excess
portions.
• Unclear or viscous liquid may not be sensed.
• Fit the fiber head to the pipe securely, otherwise the
operation may be erroneous.
• Take care that no dew condenses on the pipe’s sensing
surface or the pipe’s inside wall and no bubble attaches on
the pipe’s inside wall, since it can affect the operation.
• Neither the FD-F4Ⅺ or the FD-F9Ⅺ is waterproof or
chemical-resistant. Installation should be avoided at any
place where it could come in direct contact with water or
chemicals.
• Do not apply excessive tensile force to the fiber cable.
Cautions for FX-MR2 zoom lens usage
• The spot diameter and the sensing range are adjustable
by the screw-in depth as follows.
A
• If other tying bands are to be used, the dimension shown
in the figure below should be 2.5 mm 0.098 in or less.
• In case of mounting using the two mounting holes, use M3
screws, plain washers, and spring washers.
The tightening torque should be 0.5 N⅐m or less.
Please arrange the M3 screws, plain washers, and
spring washers separately.
(
)
• In case of mounting on the pipe with tying bands, the fiber
position can be easily adjusted.
• After FX-MR2 is set on the fiber
head at the desired depth, tighten
the attached nut securely.
Adjustment
1Unlock the release lever
(in the direction of the
arrow).
• To mount FX-MR2 with a set screw,
use a M3 set screw (cup point). The
tightening torque should be 0.29
N⅐m or less.
2Press the movable
center holders forward
to loosen the tying
bands and adjust the
position.
Caution for FX-MR3, FX-MR6 finest spot lens usage
• Screw FX-MR3, FX-MR6 on the fiber head until the fiber is
fully inserted.
The tightening torque should be 0.29 N⅐m or less.
3Lock the release lever
to its original place.
Notes: 1) Whenever the mounting position is changed, adjust the sensitivity again.
Notes: 2) The lever mechanism must be used only to adjust the position, and
not for tightening the tying bands. If tying bands are tightened while
the lever is open, and then the lever is locked, the fiber may be
damaged.
106
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
PRECAUTIONS FOR PROPER USE.
Fiber
Cautions for FX-MR5 side-view zoom lens usage
Others
• The spot diameter and the sensing range are adjustable
by the screw-in depth as follows.
• Do not use the fiber at places having intense vibrations, as
this can cause malfunction.
• Keep the fiber head surface
intact. If it is scratched or
spoiled, the detectability will
deteriorate.
• Do not expose the fiber cable
to any organic solvents.
Excluding
resistant type fiber
chemical-
(
)
• Do not use the fiber head in places where it may come in
direct contact with water. A water drop on the fiber head
deteriorates the sensing.
•
After FX-MR5 is set on the fiber
head at the desired depth, tighten
the attached nut NT-FX-MR5
securely.
• Ensure that any strong extraneous light is not incident on
the receiving face of the fiber head.
• Do not apply excessive tensile force to the fiber cable.
• Take care that the sensor is not directly exposed to
fluorescent light from a rapid-
starter lamp or a high frequency
lighting device, as it may affect the
sensing performance.
• The tightening torque should be 0.5 N⅐m or less when
tightening FX-MR5 with a screw.
Fitting protective tube
• The threaded head free-cut fiber can be fitted with a
protective tube.
• Since the sensing portion of the wide beam or narrow
beam fiber is concave shaped, take care that dust or dirt
does not collect on it.
Fitting
• In case it does collect, wipe it with a dry soft cloth.
1Insert the fiber cable into the protective tube from the
sleeve side.
2Turn the fiber head to screw it on the inner thread of the
sleeve.
Mounting
• The maximum tightening torque should be as given below.
<Sleeve part>
Tightening torque:
0.58 N⅐m or less
<Threaded part>
Tightening torque:
0.58 N⅐m or less
Note: The fiber cable must be longer than the protective tube by 30 mm
1.181 in or more to connect it to the amplifier. Make sure to measure
the length required before cutting.
107
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
DIMENSIONS (Unit: mm in)
FX-301Ⅺ
Amplifier
FX-301ⅪP
CN-73-C1 CN-73-C2
CN-71-C1 CN-71-C2
CN-71-C5
Main cable (Optional)
Sub cable (Optional)
CN-73-C5
• Length (L)
• Length (L)
Model No. Length (mm in)
Model No. Length (mm in)
CN-73-C1
CN-73-C2
CN-73-C5
1,000 39.370
2,000 78.740
5,000 196.850
CN-71-C1
CN-71-C2
CN-71-C5
1,000 39.370
2,000 78.740
5,000 196.850
MS-DIN-2
MS-DIN-E
Amplifier mounting bracket (Optional)
End plate (Optional)
Material: Cold rolled carbon steel (SPCC)
(Uni-chrome plated)
Material: Polycarbonate
108
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
DIMENSIONS (Unit: mm in)
Thru-beam type fibers
FT-FM10L
FT-SFM2L
Free-cut
Free-cut
Free-cut
Free-cut
Free-cut
Free-cut
Free-cut
With FX-AT3
With FX-AT3
With FX-AT3
With FX-AT5
With FX-AT3
Toothed lock washer "23 "0.906
FT-B8
FT-NB8
Free-cut
Free-cut
Free-cut
Free-cut
Free-cut
FT-FM2S
FT-FM2
FT-T80
FT-N8
With FX-AT3
FT-FM2S4
Toothed lock washer "8.5 "0.335
FT-SFM2
FT-NFM2
FT-SNFM2
With FX-AT3
With FX-AT4
FT-NFM2S
With FX-AT4
With FX-AT4
FT-NFM2S4
(20)
(0.787)
109
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
DIMENSIONS (Unit: mm in)
Thru-beam type fibers
FT-R80
FT-V10
Free-cut
With FX-AT3
Free-cut
Free-cut
Free-cut
With FX-AT3
With FX-AT3
With FX-AT4
With FX-AT3
With FX-AT5
Details of screw
tightening range
FT-SFM2SV2
FT-V22
FT-WA30
FT-WZ8H
FT-V41
With FX-AT2
With FX-AT3
With FX-AT5
15
0.591
FT-WA8
Free-cut
Free-cut
FT-WZ8E
Free-cut
Free-cut
FT-WZ8
FT-WKV8
Free-cut
With FX-AT5
Free-cut
With FX-AT3
Note: The emiter and receiver are symmetric.
110
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
DIMENSIONS (Unit: mm in)
Thru-beam type fibers
FT-WS8L
FT-W8
Free-cut
Free-cut
Free-cut
Free-cut
Free-cut
Free-cut
With FX-AT3
With FX-AT3
With FX-AT3
With FX-AT4
With FX-AT5
Free-cut
Free-cut
Free-cut
Free-cut
Free-cut
Free-cut
With FX-AT3
Details of
sensing part
FT-WS3
FT-WS8
With FX-AT3
With FX-AT4
With FX-AT5
With FX-AT5
With FX-AT5
Details of sensing part
Details of sensing part
FT-W4
FT-WS4
Details of
sensing part
Details of
sensing part
FT-WV42
FT-Z8E
FT-P80
FT-Z8H
FT-Z8
Note:The emitter and receiver
are symmetric.
FT-P60
Details of
sensing part
Details of
sensing part
111
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
DIMENSIONS (Unit: mm in)
Thru-beam type fibers
FT-P40
FT-P2
Free-cut
With FX-AT4
With FX-AT2
With FX-AT3
With FX-AT3
With FX-AT3
With FX-AT2
With FX-AT2
With FX-AT3
With FX-AT3
With FX-AT3
With FX-AT4
With FX-AT2
Details of
sensing part
Details of
sensing part
FT-PS1
FT-A30
Free-cut
Free-cut
Free-cut
Free-cut
Details of
sensing part
FT-A8
FT-AFM2E
FT-KV8
FT-AFM2
Free-cut
Free-cut
Free-cut
FT-K8
FT-KV1
FT-E22
Details of screw
tightening range
FT-E12
112
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
DIMENSIONS (Unit: mm in)
Thru-beam type fibers
FT-P81X
FT-H35-M2
FT-H35-M2S6
FT-H20-M1
FT-Z802Y
FT-V8Y
With FX-AT2
19.5
0.768
Details of sensing part
Toothed lock washer"8.5 "0.335 [Stainless steel (SUS)]
FT-H20W-M1
FT-H20W-M2
With FX-AT2
With FX-AT3
With FX-AT3
FT-H13-FM2
Free-cut
Free-cut
With FX-AT3
15
0.591
FT-L8Y
Free-cut
Free-cut
With FX-AT3
FT-6V
FT-60V
113
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
DIMENSIONS (Unit: mm in)
Reflective type fibers
FD-B8
FD-5
Free-cut
Free-cut
Free-cut
Free-cut
Free-cut
Free-cut
With FX-AT3
With FX-AT3
With FX-AT5
With FX-AT5
With FX-AT10
With FX-AT4
With FX-AT2
With FX-AT3
With FX-AT4
Details of sensing part
Details of
sensing part
FD-FM2S
FD-FM2
Free-cut
Free-cut
Free-cut
Free-cut
Free-cut
FD-FM2S4
Details of
sensing part
Details of
sensing
part
FD-T80
FD-T40
Details of
sensing part
Details of
sensing part
FD-S80
FD-N8
Details of
sensing part
Details of
sensing part
FD-N4
FD-NFM2
With FX-AT4
Details of
sensing part
Details of
sensing part
FD-NFM2S
FD-SNFM2
With FX-AT4
FD-NFM2S4
Details of sensing part
Details of sensing part
114
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
DIMENSIONS (Unit: mm in)
Reflective type fibers
FD-R80
FD-V41
Free-cut
Free-cut
Free-cut
Free-cut
Free-cut
Free-cut
With FX-AT3
With FX-AT3
With FX-AT3
With FX-AT5
With FX-AT4
With FX-AT6
Free-cut
Free-cut
Free-cut
Free-cut
Free-cut
Free-cut
With FX-AT4
Details of
sensing part
Details of
sensing part
"4
"0.157
FD-SFM2SV2
FD-WKZ1
With FX-AT3
With FX-AT4
With FX-AT5
With FX-AT6
With FX-AT4
Details of
sensing part
FD-W44
FD-W8
Details of
sensing part
Details of
sensing part
FD-WT8
FD-WS8
Details of
sensing part
Details of
sensing part
FD-WT4
FD-WG4
Details of sensing part
Details of
sensing part
FD-WSG4
FD-WL41
Details of sensing part
115
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
DIMENSIONS (Unit: mm in)
Reflective type fibers
FD-WL42
FD-WV42
Free-cut
Free-cut
Free-cut
With FX-AT4
Free-cut
With FX-AT4
With FX-AT5
With FX-AT4
With FX-AT3
With FX-AT3
With FX-AT6
FD-P80
Details of sensing part
FD-P60
Details of sensing part
Free-cut
12
0.472
FD-P50
Details of sensing part
FD-P40
With FX-AT5
With FX-AT2
With FX-AT3
With FX-AT6
Free-cut
Free-cut
Free-cut
Free-cut
Details of sensing part
FD-P2
FD-A15
Details of sensing part
FD-AFM2
FD-AFM2E
Free-cut
FD-G4
FD-G6
Free-cut
Details of sensing part
Details of sensing part
116
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
DIMENSIONS (Unit: mm in)
Reflective type fibers
FD-EG1
FD-EG2
With FX-AT2
With FX-AT2
With FX-AT2
With FX-AT2
Details of sensing part
FD-E12
Details of sensing part
Details of
sensing part
FD-E22
FD-EG3
With FX-AT2
Details of
sensing part
("3.2) ("0.126) Model No. tube (PVC)
FD-EN500S1
15
15
Details of sensing part
0.591 0.591
Details of sensing part
FD-ENM1S1
FD-L43
Free-cut
With FX-AT5
Details of sensing part
117
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
DIMENSIONS (Unit: mm in)
Reflective type fibers
FD-L41
FD-L42
Free-cut
With FX-AT4
Free-cut
With FX-AT4
FD-F41 FD-F91
FD-F4 FD-F9
FD-L4
FD-F8Y
FD-P81X
Free-cut
With FX-AT4
With FX-AT3
With FX-AT2
Free-cut
With FX-AT4
Free-cut
FD-G6X
Free-cut
With FX-AT6
Toothed lock washer "11 "0.433
Details of sensing part
Details of sensing part
118
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
DIMENSIONS (Unit: mm in)
Reflective type fibers
FD-H35-M2
FD-H35-M2S6
Details of
Details of sensing part
sensing part
FD-H20-M1
Details of sensing part
FD-H30-L32
FD-H18-L31
FX-LE1
FD-H20-21
Details of sensing part
FD-H35-20S
Free-cut
With FX-AT3
Details of
sensing part
FD-H13-FM2
Free-cut
With FX-AT3
Details of sensing part
FD-6V
Expansion lens (Optional)
Details of sensing part
Material: Enclosure ......Brass (Nickel plated)
Lens ..............Glass
119
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
DIMENSIONS (Unit: mm in)
FX-LE2
FX-SV1
Super-expansion lens (Optional)
Side-view lens (Optional)
Material: Enclosure ......Stainless steel (SUS303)
Lens ..............Glass
Material: Enclosure ......Brass (Nickel plated)
Lens ..............Glass
FV-LE1
FV-BR1
Expansion lens (For vacuum type fiber ⅐ Optional
)
Photo-terminal (For vacuum type fiber ⅐ Optional)
Mounting hole
Material: Enclosure ......Aluminum alloy (A6061-T6)
Lens ..............BK-7
FT-J6
FX-MR1
Fiber at atmospheric side (For vacuum type fiber ⅐ Optional)
Pinpoint spot lens (Optional)
Photo-terminal side
Amplifier side
Mounting drawing
with FD-G4
Note: In order to obtain a "0.5 mm
"0.02 in spot, it is necessary to
keep ‘?’, in the above figure,
within the specified range.
Material: Enclosure ......Aluminum (Black ALMITE)
Lens ..............Glass
FX-MR2
FX-MR3
Zoom lens (Optional)
Finest spot lens (Optional)
Mounting drawing with FD-EG1
Material: Enclosure ......Aluminum (Black ALMITE)
Material: Lens ..............Glass
#
Notes: 1) In order to obtain a "0.3 mm "0.012 in spot, it is necessary for ‘ ’,
in the above figure, to be 28.5 mm 1.122 in.
Notes: 2) When inserting the fiber, insert it fully till it stops.
Material: Enclosure ......Aluminum (Black ALMITE)
Lens ..............Glass
FX-MR5
FX-MR6
Zoom lens (Optional)
Finest spot lens (Optional)
Mounting drawing with FD-EG3
Material: Enclosure ......Aluminum (Black ALMITE)
Lens ..............Acrylic
Material: Enclosure ......PBT (Black)
Lens ..............Glass
#
Notes: 1) In order to obtain a "0.1 mm "0.004 in spot, it is necessary for ‘ ’,
in the above figure, to be 29.5 mm 1.161 in.
Notes: 2) When inserting the fiber, insert it fully till it stops.
NT-FX-MR5 (exclusive nut) is attached.
120
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301
DIMENSIONS (Unit: mm in)
FTP-Ⅺ
Mounting bracket for FX-MR2
(Accessory for FX-MR2)
MS-EX-3
Protective tube (Optional)
FDP-Ⅺ
FTP-Ⅺ, FDP-NⅪ
16
0.630
Material: Brass (Nickel plated)
FTP-NⅪ
Mounting bracket
for FD-WKZ1
Accessory for FD-WKZ1
FDP-NⅪ
Material: SPCC-SD (Zinc chromate plated)
FB-1
Fiber bender (Optional)
Model No.
Length L (mm in)
ם 10 ם 0.394 FTP-500, FTP-N500, FDP-N500, FDP-500
500
19.685
39.37
0
0
ם 10 ם 0.394 FTP-1000, FTP-N1000, FDP-N1000, FDP-1000 1,000
0
0
ם 10 ם 0.394 FTP-1500, FTP-N1500, FDP-N1500, FDP-1500 1,500
59.055
Material: PP (Containing steel blade)
0
0
Attachment for fixed-length fiber
(Accessory for fixed-length fiber)
FX-CT2
FX-AT2
Fiber cutter (Accessory for free-cut type fiber)
FX-CT2 is not attached
with the FT-NB8/N8/P80
or the FD-N8/N4/P80
A conventional FX-CT1 fiber
cutter is attached with the
FT-P80 and the FD-P80.
Material: POM
Material: ABS
Attachment for "1 mm "0.039 in fiber
FX-AT3
FX-AT4
Attachment for"2.2 mm "0.087 in fiber (Accessory)
(Accessory for "1 mm "0.039 in fiber)
FX-AT3 is not attached
with the FT-NB8/N8/P80,
FD-N8/P80
FX-AT4 is not
attached with
the FD-N4
Material: Polycarbonate
Materials: Holder..........PA (Nylon66)
Ground ........POM
Attachment for "1.3 mm "0.051 in fiber
Attachment for "1 mm / "1.3 mm "0.039 in / "0.051 in mixed fiber
FX-AT5
FX-AT6
(Accessory for "1.3 mm "0.051 in fiber)
(Accessory for "1 mm / "1.3 mm "0.039 in / "0.051 in fiber)
Materials: Holder..........PA (Nylon66)
Ground ........POM
Materials: Holder..........PA (Nylon66)
Ground ........POM
121
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301-F
Digital Fiber Sensor for Leak Detection /
Liquid Detection Fibers Only
Easy operation even for
beginners!
Optimum settings can
be realized with simple
operations
* Passed the UL 991 Environment Test
* UL 61010C-1 compatible, Passed the UL 991 Environment Test based on SEMI S2-0200.
[Category applicable for semiconductor manufacturing: TWW2, Process Equipment]
[Applicable standards: UL 61010C-1]
[Additional test / evaluation standards as per intended use: UL991, SEMI S2-0200]
For use with leak detection or liquid detection fiber only
Easy to operate with individual / collective teaching mode
Easy maintenance, as main and sub units are identical
FX-301-F is designed specifically for use
with the leak detection fiber (FD-F7 series)
or the liquid detection fiber (FT-F9 series).
You can easily set the optimum conditions.
Both main and sub units utilize the
same amplifier body. This feature
allows for easy mounting in the side-
by-side configuration. The main and
sub unit functions are distinguished
only by the proper use of 3-core main
cable and the 1-core sub cable.
Moreover, by utilizing the same body
for both main and sub units, inventory
management and maintenance is
simplified.
Individual teaching mode (TEACH)
After you select the FD-F7 series or the
FT-F9 series with the jog switch, the
optimum threshold level is automatically
set by just pressing the jog switch.
Collective teaching mode (ALL)
You can set the optimum sensitivity for
all cascaded units in one step by the
optical communications function.
Moreover, since the settings are also
copied to all units, the time involved is
considerably reduced.
Long life and stable operational settings
assure dependable performance
Flashing function incorporated
When the leak detection fiber is
connected (F7 mode), if a leak is
detected, you will recognize which fiber
detects the leak at a single glance
because the emitter will start flashing.
FX-301(P)-F incorporates our newly
developed ‘four-chemical emitting
element’, which eliminates such LED
performance deterioration. This new
element results in stable incident light
levels that can be maintained almost
indefinitely.
518
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301-F
Wiring- and labor-saving design allows side-
by-side configuration for up to sixteen units
Easy operation with MODE NAVI
Simple operation with easy access to advanced functions
Up to sixteen amplifiers can be connected in a side-by-
side configuration. As the sub cable contains only one
output line, a great amount of wiring and space can be
saved. Also, special ‘sliding’ connectors have been
provided for all main and sub cables, which can be
detached merely by releasing the lock and pulling directly
back, without having to slide the main amplifier body to
the side. Using this connector system, only a minimal
amount of space is required for regular maintenance.
MODE NAVI uses six indicators to
display the amplifier’s basic opera-
tions.
The current operating mode can be
confirmed at a glance, so even a first
time user can easily operate the
amplifier without becoming confused.
Each mode can be selected using the
large MODE key. Detailed functions
and settings can be chosen using the
large jog switch. Each setting mode
can be easily confirmed by viewing the
MODE indicator display.
The advanced features available in
each mode can be easily viewed and
smoothly selected from the digital
display.
Two switches with distinct functions
Only two switches, the large jog switch and the large MODE key, are required for operation. Depressing the large MODE key
sets the ‘mode selection’ and ‘mode cancel’ functions. The large jog switch is used to select from the detailed functions
available within each mode, as well as to change numerical values after the mode has been chosen. The use of only two
switches makes for very simple operations and easy maintenance.
ORDER GUIDE
Quick-connection cable is not supplied with the amplifier. Please order it separately.
Amplifiers
Type
Appearance
Model No.
FX-301-F
FX-301P-F
Emitting element
Output
NPN output
PNP output
NPN open-collector transistor
PNP open-collector transistor
Red LED
Quick-connection cable is not supplied with the amplifier. Please order it separately.
Main cable
Quick-connection cables
• CN-73-CⅪ
Type
Model No.
Description
Length: 1 m 3.281 ft
Length: 2 m 6.562 ft
Length: 5 m 16.404 ft
Length: 1 m 3.281 ft
Length: 2 m 6.562 ft
Length: 5 m 16.404 ft
CN-73-C1
CN-73-C2
CN-73-C5
CN-71-C1
CN-71-C2
CN-71-C5
0.15 mm2 3-core cabtyre cable, with connector
on one end
Cable outer diameter: 3.0 mm 0.118 in
Main cable
"
"
Sub cable
• CN-71-CⅪ
0.15 mm2 1-core cabtyre cable, with connector
on one end
Sub cable
"
"
Cable outer diameter: 3.0 mm 0.118 in
519
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301-F
ORDER GUIDE
End plates are not supplied with the amplifier. Please order it separately when the amplifiers are mounted in cascade.
End plates
Appearance
Model No.
Description
When cascading multiple amplifiers, or when it moves depending
on the way it is installed on a DIN rail, these end plates ensure
that all amplifiers are mounted together in a secure and fully
connected manner.
MS-DIN-E
Two pcs. per set
OPTIONS
Amplifier mounting Fiber sensor amplifier
Designation
Model No.
Description
bracket
protection seal
• MS-DIN-2
• FX-MB1
Mounting bracket for amplifier
Amplifier mounting bracket
MS-DIN-2
10 sets of 2 communication window seals and 1 connector seal
Communication window seal:
It prevents malfunction due to transmission signal from another
amplifier, as well as, prevents effect on another amplifier.
Connector seal:
Fiber sensor amplifier
protection seal
FX-MB1
It prevents contact of any metal, etc., with the pins of the quick-
connection cable.
SPECIFICATIONS
Type
Model No.
NPN output
PNP output
FX-301P-F
FX-301-F
Item
Applicable fibers
FD-F7 series, FT-F9 series
Supply voltage
12 to 24 V DC
ע 10 % Ripple P-P 10 % or less Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
Power consumption
Output
NPN open-collector transistor
PNP open-collector transistor
• Maximum sink current: 100 mA (50 mA, if five, or more,
amplifiers are connected in cascade.)
• Maximum source current: 100 mA (50 mA, if five, or
more, amplifiers are connected in cascade.)
•
•
Applied voltage: 30 V DC or less (between output and 0 V)
Residual voltage: 1.5 V or less [at 100 mA (50 mA, if five, or
more, amplifiers are connected in cascade.) sink current]
•
•
Applied voltage: 30 V DC or less (between output and
ם V) Residual voltage: 1.5 V or less [at 100 mA (50 mA, if five, or
more, amplifiers are connected in cascade.) source current]
Output operation
Short-circuit protection
Response time
Leak setting (F7 mode): OFF with detection of leak, Liquid setting (F9 mode): Using the jog switch, choose the signal OFF condition between absence of liquid and presence of liquid.
Incorporated
250!s or less (Note 1)
Sensitivity setting
Operation indicator
Model indicator
Individual teaching / Collective teaching
Orange LED (lights up when the output is ON)
Green LED [lights up during liquid setting (F9 mode)]
RUN: Green LED, TEACH ꢀ ALL ꢀ ADJ ꢀ DISP ꢀ OUT:Yellow LED
4 digit red LED display
MODE indicator
Digital display
Fine sensitivity adjustment function
Timer function
Incorporated
Delay timer [used only for liquid setting (F9 mode)] (Timer setting selectable from 10 ms, 100 ms, 1,000 ms, and none)
0 to
ם 50 ЊC ם 32 toם 122 ЊF (If 8 to 16 units are connected in cascade: 0 toם 45 ЊC ם 32 toם 113 ЊF (No dew condensation), Storage:
מ 20 toם 70 ЊC מ 4 toם 158 ЊF Ambient temperature
Ambient humidity
Ambient illuminance
EMC
35 to 85 % RH, Storage: 35 to 85 % RH
Sunlight: 10,000 ?x at the light-receiving face, Incandescent light: 3,000 ?x at the light-receiving face
EN 50081-2, EN 50082-2, EN 60947-5-2
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Emitting element
Material
1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 2)
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 2)
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each
Red LED (modulated)
Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, Switch: Acrylic
Connector (Note 3)
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Connecting method
Cable extension
Weight
20 g approx.
Notes: 1) When detecting leak (output OFF) during leak setting (F7 mode), since the sensor flashes the emitted light, only the response action for turning the signal back to ON is delayed (1 sec. approx.).
Notes: 2) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
Notes: 3) The cable for amplifier connection is not supplied as an accessory. Make sure to use the optional quick-connection cable given below.
Main cable (3-core): CN-73-C1 (cable length 1 m 3.281 ft), CN-73-C2 (cable length 2 m 6.562 ft), CN-73-C5 (cable length 5 m 16.404 ft)
Sub cable (1-core): CN-71-C1 (cable length 1m 3.281 ft), CN-71-C2 (cable length 2 m 6.562 ft), CN-71-C5 (cable length 5 m 16.404 ft)
520
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301-F
Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : NPN output transistor
Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : PNP output transistor
521
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301-F
PRECAUTIONS FOR PROPER USE
Cascading amplifiers
This product is not a safety sensor. Its use is not
intended or designed to protect life and prevent body
injury or property damage from dangerous parts of
machinery. It is a normal object detection sensor.
• Make sure that the power supply is off while cascading or
removing the amplifiers.
• Make sure to check the allowable ambient temperature, as it
Mounting
depends on the number of amplifiers connected in cascade.
• In case two, or more, amplifiers are connected in cascade, make
sure to mount them on a DIN rail.
How to mount the amplifier
1
Fit the rear part of the mounting
section of the amplifier on a
• When connecting in cascade, mount the amplifiers close to each
other, fitting them between the optional end plates (MS-DIN-E)
mounted at the two ends.
35 mm
width DIN rail.
1.378 in
2
Press down the front part of the
mounting section of the amplifier on
the 35 mm 1.378 in width DIN rail.
• When the amplifiers move on the DIN rail depending on the
attaching condition, fitting them between the optional end plates
(MS-DIN-E) mounted at the two ends.
• Up to maximum 15 amplifiers can be added (total 16 amplifiers
connected in cascade.)
How to remove the amplifier
1
Push the amplifier forward.
• When connecting more than two amplifiers in cascade, use the
sub cable (CN-71-CⅪ) as the quick-connection cable for the
second amplifier onwards.
2
Lift up the front part of the amplifier
to remove it.
Note: Take care that if the front part is lifted
up without pushing the amplifier
forward, the hook on the rear portion
of the mounting section is likely to
break.
• Since the model setting gets changed if collective teaching is
done for the amplifiers in Leak setting (F7 mode) and in Liquid
setting (F9 mode) mounted in cascade, note that collective
teaching should not be done for amplifiers with different model
settings mounted in cascade.
How to connect the fiber cables
• Since the communication function of this amplifier and that of
the fiber sensor FX-301/311 series is different, if these models
are mounted in cascade, do not use the communication
function.
• Make sure to fit the fiber attachment (FX-AT4), enclosed with
the fiber, to the fibers.
Please refer to the instruction manual of the fiber attachment for
the fitting method.
• In case of cascading, wait for 10 minutes, or more, to use the
teaching function after the power is switched on.
1
2
Snap the fiber lock lever down.
Cascading method
Insert the fiber cables slowly into
the inlets until they stop. (Note)
1
Mount the amplifiers, one by one,
on the 35 mm 1.378 in width DIN
rail.
3
Return the fiber lock lever to the
original position, till it stops.
(For details, refer to ‘Mounting’.)
Note: In case the fiber cables are not
inserted to a position where they stop,
the sensing becomes unstable.
2
3
Slide the sub units next to each
other, and connect the quick-
connection cables.
Mount the optional end plates
(MS-DIN-E) at both the ends to
hold the amplifiers between their
flat sides.
Connection
• Make sure that the power supply is off while connecting or
disconnecting the quick-connection cable.
4
Tighten the screws to fix the end
plates (MS-DIN-E).
Connection method
1
Holding the connector of the quick-
connection cable, align its projec-
tion with the groove at the top
portion of the amplifier connector.
Dismantling method
1
Loosen the screws of the end
plates (MS-DIN-E).
2
3
Remove the end plates (MS-DIN-E).
Slide the sub units and remove
them one by one.
2
Insert the connector till a click is
felt.
(For details, refer to ‘Mounting’.)
Disconnection method
1
Pressing the projection at the top of
the quick-connection cable connec-
tor, pull out the connector.
Note: Take care that if the connector is
pulled out without pressing the
projection, the projection may break.
Do not use a quick-connection cable
whose projection has broken.
Further, do not pull by holding the
cable, as this can cause a cable-
break.
522
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301-F
PRECAUTIONS FOR PROPER USE
Part description
Individual teaching mode
• The sensitivity selection function is set to the automatic
sensitivity setting ( ) at the time of factory shipment. In
case sensitivity selection setting is done, make sure to carry
out ‘teaching’ after the sensitivity selection setting.
• For the sensitivity selection setting, refer to ‘Sensitivity
selection function’ on p.525.
• When MODE indicator / TEACH (yellow) lights up, threshold value
can be set on a single unit.
1
2
3
Operation indicator (Orange)… Lights up when output is ON.
Model indicator (Green)… Lights up during liquid setting (F9 mode).
MODE indicators…
Step
Description
Display
RUN (Green) : Lights up during normal sensing
operation.
TEACH (Yellow): Lights up when the individual
teaching mode is selected.
ALL (Yellow) : Lights up when the collective
teaching mode is selected.
ADJ (Yellow) : Lights up when the threshold value
fine adjustment mode is selected or
the sensitivity switching function is
activated.
DISP (Yellow): Lights up when the digital display
setting mode is selected or the timer
Insert Leak detection fiber
(FD-F7Ⅺ) or Liquid
detection fiber (FT-F9Ⅺ).
Press MODE key to light
1
up MODE indicator
TEACH (yellow).
/
Turn the jog switch to ‘
ם ’ or ‘
מ ’ side to set to either Leak (F7) mode (
(F9) mode (
) or Liquid
2
3
).
In case Liquid (F9) mode
is set, the model
(
)
indicator (Green) lights up.
Press Jog switch in no-leak
condition with Leak detection
fiber (FD-F7Ⅺ) or no-liquid
condition with Liquid detection
function is activated.
OUT (Yellow) : Lights up when the forced output
mode is selected or the NO / NC
switching function is activated.
fiber (FT-F9Ⅺ). Then, ‘
’ on
4
5
Jog switch... Moving this switch in the ‘
ם ’ or ‘מ ’ direction, allows different items to be viewed for selection
and pressing the switch then confirms the selected
setting.
MODE key... This key is used to select operating modes and to
cancel settings during the configuration process.
the display moves from left to
right.
When teaching is accepted, the result of threshold
value setting is displayed.
• In case stable sensing is possible: ‘
display blinks three times.
• In case stable sensing is not possible: ‘
the display blinks. (Note 1)
’ on the
4
5
’ on
Setting items
If the teaching result is ‘
’, the sensor returns to
RUN mode automatically and the incident light
intensity is shown on the display.
MODE indicator / RUN (green) lights up.
The setting is complete.
Notes: 1) For details, refer to ‘Error indication’ on p.526.
Notes: 2) The initial setting at the time of factory shipment is Liquid (F9)
mode ( ).
Notes: 3) Do not move or bend the fiber cable after the sensitivity setting.
Detection may become unstable.
RUN Mode
•
When MODE indicator / RUN (green) lights up, the display setting or the
sensitivity select setting can be checked. Refer to ‘Sensitivity selection
function’ on p.605 for further details of sensitivity select setting.
How to change to ‘percent display’
•
When Jog switch is pressed for 2 sec., or more, the display
changes as per the diagram below.
How to check the sensitivity state
•
If Jog switch is turned to ‘
ם ’ or ‘מ ’ side, the present sensitivity state can be confirmed. After 2 sec., the display returns to ‘digit display’ or ‘percent display’.
523
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301-F
PRECAUTIONS FOR PROPER USE
Collective teaching mode
Threshold value fine adjustment mode
• When MODE indicator / ALL (yellow) lights up, a threshold value
• When MODE indicator / ADJ (yellow) lights up, the set threshold
can be collectively set to amplifiers mounted in cascade.
value can be fine adjusted.
Step
Description
Display
Step
Description
Display
Insert Leak detection fiber
Press MODE key to light up
(FD-F7Ⅺ) or Liquid
detection fiber (FT-F9Ⅺ).
Press MODE key to light
up MODE indicator / ALL
(yellow).
MODE indicator
(yellow).
/
ADJ
1
1
Turn the jog switch to ‘
ם ’ or Turn Jog switch to the ‘
ם ’ side, to increase the threshold value.
Turn Jog switch to the ‘
מ ’ side, to decrease the threshold value.
‘
מ ’ side to set to either Leak (F7) mode (
(F9) mode (
) or Liquid
2
).
2
In case Liquid (F9) mode
is set, the model
(
)
indicator (green) lights up.
Press Jog switch in no-leak
condition with Leak detection
fiber (FD-F7Ⅺ) fitted or no-liquid
condition with Liquid detection
fiber fitted (FT-F9Ⅺ).
When Jog switch is pressed,
the changed threshold value
blinks 3 times and is confirmed.
3
4
3
Then, ‘
’ on the display
When MODE key is pressed 3 times, or for 2 sec., or
more, the sensor returns to the RUN mode and the
incident light intensity is shown in the display.
MODE indicator / RUN (green) lights up.
The setting is complete.
moves from top left to top right
and from bottom right to bottom
left (twice).
When teaching is accepted, the result of threshold
value setting is displayed.
Note: The adjustable area is limited as shown below. In order to adjust the
threshold the outside the adjustable area, confirm it within the area
once and then adjust it again.
• In case stable sensing is possible: ‘
display blinks three times.
• In case stable sensing is not possible: ‘
the display blinks. (Note 1)
’ on the
4
5
’ on
If the teaching result is ‘
’, the sensor returns to
RUN mode automatically and the incident light
intensity is shown on the display.
MODE indicator / RUN (green) lights up.
The setting is complete.
Notes: 1) For details, refer to ‘Error indication’ on p.526.
Notes: 2) In collective teaching, only an instruction of the teaching operation
is transmitted, the threshold value is not copied. The threshold
value taught at the respective amplifier is set.
Notes: 3) When the collective teaching is done, the setting conditions are
copied. In case an individual setting condition is desired to be set,
set it individually after the collective teaching.
Notes: 4) Do not move or bend the fiber cable after the sensitivity setting.
Detection may become unstable.
Digital display setting mode
•
When MODE indicator / DISP (yellow) lights up, the digital display can
be switched to the light-up mode, the eco mode or the inverse mode.
Step
Description
Display
:
:
g Copied
ן Not copied Press MODE key to light
up MODE indicator / DISP
(yellow).
Digit display
Percent display
Digital display Sensitivity
setting
NO / NC selection
Timer function
Mode
Model setting
g
selection function
function
1
Leak (F7)
mode
ן ן g
g
g
g
g
g
Liquid (F9)
mode
g
g
g
When Jog switch is turned to the ‘
side, the mode in the digital display changes.
ם ’ side or ‘מ ’ Notes: 5) The collective teaching transmits the information only in the
direction of the arrow shown on the amplifier operation panel.
The collective teaching is also possible from the middle of the
amplifiers mounted in cascade. Check the direction of the
transmission before collective teaching is done.
:
:
This is the light-up mode in the
digital display.
The digital display always lights up.
This is the eco mode. After
confirmation, if key operation has not
been done for 8 sec., or more, ‘
’
2
flashes, and then the digital display is turned off.
When a key operation is done after the display is turned
off or when the collective teaching is carried out, the
digital display lights up.
:
This is the inverse mode of the digital display.
In the normal display condition, the display changes
to the inverse display and in the inverse condition,
the display changes to the normal display.
When Jog switch is pressed, the
set display blinks 3 times and is
confirmed.
3
4
Notes: 6) Since the model setting is also transmitted, do not carry out
When MODE key is pressed twice or for 1 sec., or
more, the sensor returns to RUN mode and the
incident light intensity is displayed.
collective teaching when the amplifiers in Leak (F7) mode (
and in Liquid (F9) mode ( ) are mixed in cascade connection.
Notes: 7) Do not move or bend the fiber cable after the sensitivity setting.
Detection may become unstable.
)
• MODE indicator / RUN (green) lights up.
• The setting is complete.
Note:The initial setting at the time of factory shipment is the light-up mode
(
).
524
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301-F
PRECAUTIONS FOR PROPER USE
Forced output mode
Timer function [Liquid (F9) mode only]
•
When MODE indicator / OUT (yellow) lights up, the output can be
compulsory changed to ON or OFF regardless of the incident light intensity.
• The timer setting can be done by pressing the jog switch for 3
sec., or more, when Liquid (F9) mode ( ) has been set and
MODE indicator / DISP (yellow) lights up. In case of Leak (F7)
mode ( ), the display does not change to the timer function.
Step
Description
Display
Press MODE key to light up
For the selection method of Leak (F7) mode / Liquid (F9) mode,
refer to ‘Individual teaching mode’ on p.523 or ‘Collective
teaching mode’ on p.524.
• This product incorporates a delay timer which reduces the effect
of air bubbles, etc.
MODE indicator
(yellow).
/
OUT
1
(Present output state is
displayed.)
When Jog switch is turned to the
‘
ם ’ side or ‘מ ’ side, the output is compulsory changed to ON or
OFF.
Since the emitting element of the
amplifier blinks, it is possible to
check the fiber connected to the
amplifier.
2
When the output is compulsory
changed to ON, the operation
indicator (orange) lights up.
Press MODE key to return
the sensor to step 1.
3
4
When MODE key is pressed, the sensor returns to RUN
mode and the incident light intensity is displayed.
MODE indicator / RUN (green) lights up.
The setting is complete.
Sensitivity selection function
•
If Jog switch is pressed for 3 sec., or more, when MODE indicator /
ADJ (yellow) lights up, the sensitivity can be fixed to low sensitivity
or high sensitivity, or set to automatic sensitivity.
Step
Description
Display
Confirm if the sensor is in Liquid (F9) mode
(
)
in
1
‘Individual teaching mode’ or ‘Collective teaching
mode’.
Step
Description
Display
Press MODE key to light up
Press MODE key to light up
MODE indicator
(yellow).
/
ADJ
MODE indicator
(yellow).
/
DISP
1
2
2
3
Press Jog switch for 3 sec. or
more.
The sensor goes into the sen-
sitivity setting condition.
MODE indicator / RUN (green)
blinks.
Press Jog switch for 3 sec., or
more.
(
(
The sensor goes into the timer
(
(
setting condition.
MODE indicator / RUN (green)
blinks.
When Jog switch is turned to the
When Jog switch is turned to the
‘
ם ’ side or ‘מ ’ side, the display ‘
ם ’ side or ‘מ ’ side, the display and MODE indicator
/
RUN
and MODE indicator
/
RUN
(green) blinks, and the sensitivity
can be selected.
(green) blinks, and the timer
period can be chosen.
:
Automatic sensitivity setting
After selecting the auto-
matic sensitivity, the opti-
mum sensitivity is set by
carrying out teaching.
4
3
: Without timer
: 10 ms timer
: 100 ms timer
: 1,000 ms timer
: Low sensitivity setting
: High sensitivity setting
When Jog switch is pressed,
setting display blinks 3 times and
is confirmed.
When Jog switch is pressed, the
setting display blinks 3 times and
is confirmed.
5
6
7
4
5
The sensor returns to step 2.
MODE indicator / TEACH (green) lights up and
‘
’ or ‘
’ is displayed.
When MODE key is pressed twice or for 1 sec., or
more, the sensor returns to RUN mode and the
incident light intensity is displayed.
MODE indicator / RUN (green) lights up.
The setting is complete.
After sensitivity selection, carry out the teaching.
For the setting method of teaching, refer to
‘Individual teaching mode’ on p.603.
Note: The initial setting at the time of factory shipment is the automatic
sensitivity setting
(
).
Note: The initial setting at the time of factory shipment is the without timer
condition.
(
)
525
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301-F
PRECAUTIONS FOR PROPER USE
NO / NC selection function [Liquid (F9) mode only]
Wiring
• The NO / NC selection can be done by pressing the jog switch for
• Make sure that the power supply is off while wiring.
• Verify that the supply voltage variation is within the rating.
• Take care that if a voltage exceeding the rated range is applied, or
if an AC power supply is directly connected, the sensor may get
burnt or damaged.
• In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this product, connect the
frame ground (F.G.) terminal of the equipment to an actual
ground.
3 sec., or more, when Liquid (F9) mode (
) has been set and
MODE indicator / DISP (yellow) lights up. In case of Leak (F7)
mode (
), the display does not change to NO / NC selection
function.
For the selection method of Leak (F7) mode / Liquid (F9) mode,
refer to ‘Individual teaching mode’ on p.603 or ‘Collective
teaching mode’ on p.604.
Step
Description
Display
• If power is supplied from a commercial switching regulator, ensure
that the frame ground (F.G.) terminal of the power supply is
connected to an actual ground.
Confirm if the sensor is in Liquid (F9) mode
1
(
) in ‘Individual teaching mode’ or
‘Collective teaching mode’.
• Make sure to use an isolation transformer for the DC power
supply. If an auto-transformer (single winding transformer) is used,
this product or the power supply may get damaged.
• In case a surge is generated in the used power supply, connect a
surge absorber to the supply and absorb the surge.
• Take care that short-circuit or wrong wiring of the load may burn
or damage the sensor.
• Do not run the wires together with high-voltage lines or power
lines or put them in the same raceway. This can cause
malfunction due to induction.
Press MODE key to light up
MODE indicator
(yellow).
/
OUT
2
3
Press Jog switch for 3 sec., or
more.
(
The sensor goes into the NO /
NC setting condition.
MODE indicator / RUN (green)
blinks.
(
• Make sure to use the optional quick-connection cable for the
connection of the amplifier. Extension up to total 100 m 328.084 ft
is possible with 0.3 mm2, or more, cable. However, in order to
reduce noise, make the wiring as short as possible.
When Jog switch is turned to the ‘
ם ’ side or ‘
מ ’ side, the display and MODE indicator / RUN (green) blinks,
and NO / NC can be chosen.
4
5
: Normally closed (OFF in
liquid absent condition.)
: Normally open (OFF in liquid
present condition.)
Others
• Do not use during the initial transient time (0.5 sec. approx.) after
the power supply is switched on.
• Take care that the sensor is not directly exposed to fluorescent
light from a rapid-starter lamp or a high frequency lighting device,
as it may affect the sensing performance.
When Jog switch is pressed,
setting display blinks 3 times and
is confirmed.
• Avoid dust, dirt, and steam.
• When the fiber head gets dusty or dirty etc. the sensitivity
deteriorates. To keep stable detection, wipe the fiber head to
remove dust or dirt etc. and carry out sensitivity teaching
periodically.
• This sensor is suitable for indoor use only.
• Take care that the product does not come in direct contact with
6
7
The sensor returns to the step 2.
When MODE key is pressed, the sensor returns to RUN
mode and the incident light intensity is displayed.
MODE indicator / RUN (green) lights up.
The setting is complete.
water, oil, grease, or organic solvents, such as, thinner, etc.
• This sensor cannot be used in an environment containing
Note: The initial setting at the time of factory shipment is the normal close
) setting.
(
inflammable or explosive gases.
• Never disassemble or modify the sensor.
Error indication
• When an error is displayed, remedy as follows.
Error indication
Cause
Remedy
Excessive current
flows due to a short-
circuit.
Switch off the power supply
and check the load.
Check the installation condition
of the fiber, or whether the
fiber has come out, and then
do teaching again.
Press MODE key to cancel
‘
’. After the cancellation,
the sensor operates at the set
value conditions before the
error. However, in case the
sensitivity selection function
has been set to the automatic
The teaching is ab-
normal.
sensitivity setting (
), the
sensor operates at optimum
sensitivity.
Check if the amplifiers
mounted in cascade are
disconnected. After the
confirmation, do the teaching
again.
The communication is
abnormal.
526
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-301-F
527
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
SERIES
FX-305
Digital Fiber Sensor
Digital Fiber Sensor
with 2 independent
outputs
APC circuit
Four-chemical
emitting element
Double coupling lens
New Advanced sensor with Visible Indicator
Industry’s largest display 9999
Industry first! Light-emitting amount selection function
If the light-receiving level becomes saturated during close-range sensing or when
sensing transparent or ultra-small objects, you can adjust the light-emitting amount
of the sensor to stabilize sensing without needing to change the response time.
Sensing that previously required the response time or fibers to be changed can now
be set much more easily using this function.
Industry’s largest display with 4 digits (9999). With a greater difference in digit value
than previous models, threshold values can be set in units of 1 digit up to maximum
9999. Threshold setting can now be done more easily and accurately.
● Digit difference comparison
[Light-receiving level saturated]
[Stable sensing]
Example
object A
object B
and
Digit difference between
Actual digit difference: 3000
Upper display limit
(12000)
9999
Previous models
4000
FX-305
9999
Actual digit difference: 3000
9000
(During STDF, LONG
and U-LG modes)
6000
3000
Saturated digit
difference: 999
Light-emitting
amount
changed
Digit difference: Small
Digit difference: Large
● Comparison of saturation remedies
[Conventional models]
[FX-305]
Independent dual outputs
Response time: Mode selection
Affects positioning precision
Industry
First
Two independent output channels are provided, so that one sensor can be used for
control tasks that previously required two sensors. In addition, the second output
channel can be used for simple self-diagnosis and alarm output, so that ease of
maintenance is improved.
Variable light
amount function
Makes steps such
as those at left
unnecessary.
Changing fiber: Change to thinner fiber to reduce light amount
Man-hour and cost inefficiencies
Changing setting position: Increase sensing range
Space and man-hour inefficiencies
Example
Sensing meandering of sheets
ON
Too far left
Twice
OUT1
as fast as
before
High-speed response 65µs
OFF
ON
OK
High-speed response that is about twice as fast as before has been achieved. Even
small objects moving at high speeds can be sensed. In addition, interference
between two units is prevented in high-speed mode (H-SP).
OUT2
OFF
Too far right
Stable sensing over long and short periods
Conventional
models
2 sensors needed
[
]
In addition to a ‘four-chemical emitting element’
● Stable sensing comparison
FX-305
which suppresses changes in the light-emitting
[FX-305]
1 sensor is enough!
Actual position
Meandered position
Short-term stability
Three-chemical
element over time so that a stable level of light
emitting
Deviation
element,
No APC
emission can be maintained over long periods, a
new ‘Auto Power Control (APC) circuit’ has also
been adopted. Because fluctuations over short
periods of time have also been suppressed,
stable sensing is possible very quickly once the
power is turned back on after setup changes.
Largest number in the industry! Automatic interference
prevention of up to 16 units
Can be used even in places where fibers need to be installed close together.
Long-term stability
Time
122
Download from Www.Somanuals.com. All Manuals Search And Download.
08/2005
FX-305
SPECIFICATIONS
I/O CIRCUIT
FX-305
Type
NPN output
PNP output
NPN output type
Color code of quick-connection cable
Model No.
FX-305
FX-305P
Item
Terminal No.
Thru-beam type (FT-B8): 1,700 (U-LG), 1,100 (LONG), 730 (STDF)
530 (STD), 400 (FAST), 200 (H-SP)
Reflective type (FD-B8): 600 (U-LG), 480 (LONG), 280 (STDF)
D
(Brown)
ם V (Note 1) Sensing range
(mm)
1
3
Load
(Black) Output 1
Tr1
220 (STD), 160 (FAST), 85 (H-SP)
ם מ Load
12 to 24 V DC
10 %
50 mA max. (Note 2)
(White) Output 2
ע Tr2
ZD1
Supply voltage
12 to 24 V DC
ע 10 % Ripple P-P 10 % or less 4
50 mA max. (Note 2)
(Blue) 0 V (Note 1)
ZD22
Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
S
Power consumption
Internal circuit
Users’ circuit
NPN open-collector transistor
PNP open-collector transistor
•
Maximum sink current: each 50 mA (Note1)
•
Maximum source current: each 50 mA (Note1)
Notes: 1) The quick-connection sub cable does not have
ם V (brown) and 0 V (blue). Output
(Output 1, Output 2)
• Applied voltage: 30 V DC or less
(between output and 0 V)
• Residual voltage: 1.5 V or less
• Applied voltage: 30 V DC or less
The power is supplied from the connector of the main cable.
2) 25 mA max., if five amplifiers, or more, are connected together.
(between output and
ם V) • Residual voltage: 1.5 V or less
Symbols … D: Reverse supply polarity protection diode
ZD1, ZD2: Surge absorption zener diode
Tr1, Tr2: NPN output transistor
[at each 50 mA (Note 1) sink current]
[at each 50 mA (Note 1) source current]
Output operation Selectable either Light-ON or Dark-ON, with jog switch
Short-circuit protection
Incorporated
Response time
(Note 2)
H-SP: 65 !s or less, FAST 150 !s or less, STD: 250 !s or less, STDF: 700 !s or less,
LONG: 2.5 ms or less, U-LG: 4.5 ms or less selectable with jog switch
FX-305P
PNP output type
Color code of quick-connection cable
Digital display
4-digit red LED display
Terminal No.
Normal mode: 2-level teaching / Limit teaching / Full-auto teaching /
Max. sensitivity teaching / Manual adjustment
Window comparator mode: Teaching (1-level / 2-level / 3-level) /
Manual adjustment
(Brown)
ם V (Note 1) 1
ZD1
50 mA max. (Note 2)
Sensitivity setting
3
ם מ 12 to 24 V DC
10 %
Tr1
(Black) Output 1 50 mA max. (Note 2)
ZD2
ע 4
2
Load
Fine sensitivity adjustment function
Incorporated
Tr2
(White) Output 2
Load
Incorporated with variable ON-delay
/
OFF-delay
/
ONE-SHOT
/
ON-delay⅐OFF-
(Blue) 0 V (Note 1)
Users’ circuit
D
delay / ON-delay⅐ONE-SHOT timer, switchable either effective or ineffective
(Timer period Output 1: 0.5 ms, 1 to 9999 ms, Output 2: 0.5 ms, 1 to 500 ms)
Timer function
Internal circuit
Notes: 1) The quick-connection sub cable does not have
ם V (brown) and 0 V (blue). Automatic interference prevention
function (Note 2) (Note 3)
Incorporated [Up to 4 sets of fiber heads can be mounted close together
(However, U-LG mode is 8 sets, H-SP mode is 2 sets.)]
The power is supplied from the connector of the main cable.
2) 25 mA max., if five amplifiers, or more, are connected together.
מ 10 to ם 55 °C ם 14 to ם 131 °F Symbols … D: Reverse supply polarity protection diode
ZD1, ZD2: Surge absorption zener diode
Tr1, Tr2: PNP output transistor
If 4 to 7 units are connected in cascade:
מ 10 to ם 50 °C ם 14 to ם 122 °F, Ambient temperatu-
re
(
)
if 8 to 16 units are connected in cascade:
מ 10 to ם 45 °C ם 14 to ם 113 °F (No dew condensation or icing allowed),
Storage:
מ 20 to ם 70 °C מ 4 to ם 158 °F Ambient humidity
Emitting element
35 to 85 % RH, Storage: 35 to 85 % RH
Red LED (modulated)
DIMENSIONS (Unit: mm in)
FX-305
Enclosure: Heat-resistant ABS, Transparent cover: Polycarbonate
Press switches: Acrylic, Jog switch: Heat-resistant ABS
Material
Amplifier
FX-305P
Connecting method
Cable extension
Weight
Connector (Note 4)
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
20 g approx.
48.2 1.898
12
0.472
26.3 1.035
0.7
0.028
8.3
0.327
2.5
0.098
Notes: 1) 50 mA per output. 25 mA if five, or more, amplifiers are connected
in cascade.
Output 1 operation indicator
(Orange)
MODE key
Jog switch
2) When the interference prevention function ‘
’ is set, the number
Output 2 operation indicator
(Orange)
of mountable fibers becomes double. Furthermore, take care that
the response time also becomes double.
Digital display (Red)
64.5 2.539
3) When the power supply is switched on, the light emission timing is
automatically set for interference prevention.
4) The cable for amplifier connection is not supplied as an accessory.
Make sure to use the optional quick-connection cables given below.
Main cable (4-core): CN-74-C1 (cable length 1 m 3.281 ft), CN-74-C2 (cable length 2 m 6.562 ft)
CN-74-C5 (cable length 5 m 16.404 ft)
Sub cable (2-core): CN-72-C1 (cable length 1 m 3.281 ft), CN-72-C2 (cable length 2 m 6.562 ft)
3
10
3.3 0.13
0.118
0.394
27.8 1.094
Communication
window
7 0.276
Beam-
emitting
part
CN-72-C5 (cable length 5 m 16.404 ft)
□
□
CN-73-C and CN-71-C cannot be used.
30
3
1.181
0.118
7 0.276
7 0.276
Beam-
receiving
part
10.5 0.413
PRECAUTIONS FOR PROPER USE
3.95
0.156
13.5
0.531
36.5
1.437
Suitable for 35 mm 1.378 in
width DIN rail
This product is not a safety sensor. Its use is not intended or designed
to protect life and prevent body injury or property damage from
dangerous parts of machinery. It is a normal object detection sensor.
All information is subject to change without prior notice.
123
Download from Www.Somanuals.com. All Manuals Search And Download.