| NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET   Typical Charge Characteristics   HHR450A   Cylindrical L-fat A size (HR 18/67)   2.0   1.9   1.8   1.7   1.6   1.5   1.4   1.3   1.2   1.1   1.0   0.9   0.8   Dimensions (with Tube)   (mm)   Charge: 1500mA- V=10mV   18.2+-0   0.7   (+)   0˚C   20˚C   45˚C   0 20 40 60 80 100 120 140 160 180 200 220   Charge Time (minutes)   67.0+-0   1.5   Typical Discharge Characteristics   1.8   Charge: 2000mA dT/dt=1.0˚C/min,20˚C   Disharge Temperature: 20˚C   1.7   1.6   1.5   1.4   1.3   1.2   1.1   1.0   0.9   0.8   ( ) Specifications   mm   18.2+0/-0.7   67.0+0/-1.5   Grams   inch   900mA(0.2 It)   0.72+0/-0.03   2.64+0/-0.06   Ounces   Diameter   Height   0 1 2 3 4 5 6 Discharge Time (hours)   Approximate   Weight   60   2.12   Nominal Voltage   1.2V   1.8   1.7   1.6   1.5   1.4   1.3   1.2   1.1   1.0   0.9   0.8   Average**   4500 mAh   4200 mAh   Discharge   Capacity*   Charge: 2000mA dT/dt=1.0˚C/min,20˚C   Disharge Temperature: 20˚C   Rated (Min.)   Approx. Internal impedance   at 1000Hz at charged state.   25mΩ   Standard   420mA (0.1It) x 16hrs.   2000mA dT/dt   Charge   Rapid***   F ˚ C ˚ Standard   Charge   0˚C to 45˚C   0˚C to 40˚C   32˚F to 113˚F   32˚F to 104˚F   14˚F to 149˚F   -4˚F to 95˚F   -4˚F to 113˚F   -4˚F to 131˚F   Rapid   Discharge   < 1 year   2000mA(0.44 It)   4500mA(1 It)   -10˚C to 65˚C   -20˚C to 35˚C   -20˚C to 45˚C   -20˚C to 55˚C   0 20   40   60   80   100   120   140   Discharge Time (minutes)   Storage   < 3 months   < 1 month   * After charging at 0.1It for 16 hours, discharging at 0.2It.   ** For reference only.   *** For rapid charge: use dT/dt charge termination method. Refer to the   Nickel Metal Hydride “Charge Methods” section for further details.   Battery performance and cycle life are strongly affected by how they   are used. In order to maximize battery safety, please consult Panasonic   when determining charge / discharge specs, warning label contents   and unit design.   Note: [It] was previously expressed as [C]. [It] is an IEC standard expression   for the amount of charge or discharge current and is expressed as:   It(A) = Cn (Ah)/1h.   • [It] is the reference test current in ampres   • [Cn] is the rated capacity of the cell or battery in Ampere-hours.   n = the time base [hours] for which the rated capacity is declared   AUGUST 2005   NICKEL METAL HYDRIDE HANDBOOK   modification without notice. Contact Panasonic for the latest information.   This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to   Download from Www.Somanuals.com. All Manuals Search And Download.   |