Reset.........................................................................6
Specifications ..........................................................7
Precautions..............................................................7
About Oregon Scientific .........................................8
EU-Declaration of conformity.................................8
FCC Statement.........................................................8
Smart Weather Station
With auto-rotating screen
Model: BAR610P / BAR610PA /
BAR610PU
USER MANUAL
CONTENTS
Overview...................................................................2
Front view ..............................................................2
Back view...............................................................2
Remote sensor ......................................................3
Getting started.........................................................3
Main unit installation ..............................................3
Remote sensor installation ....................................3
Clock.........................................................................4
Clock reception......................................................4
Manually set clock .................................................5
Alarm ........................................................................5
Weather forecast .....................................................6
Temperature ............................................................6
Projection.................................................................6
Auto-rotating screen ...............................................6
Backlight ..................................................................6
1
BAR610P_M_EN_R3.indd
1
12/9/08 17:55:32
Download from Www.Somanuals.com. All Manuals Search And Download.
flip projected image 180°
10. °C / °F: Select temperature unit
11. Battery compartment
12. RESET: Reset unit to default settings
13. AC/DC Adaptor socket
GETTING STARTED
MAIN UNIT INSTALLATION
For continuous use of projector, install adapter.
•
Plug AC/DC adaptor into socket. Make sure the
adapter is not obstructed and is easily accessible
to the unit.
14. Wall mount holes
REMOTE SENSOR
To completely disconnect from power, the adapter
should be disconnected from the main unit.
FRONT VIEW
BACK VIEW
NOTE The main unit and adapter should not be
exposed to wet conditions. No objects filled with liquid,
such as vases, should be placed on the main unit and
adapter.
5
6
1
2
Insert batteries:
1. Remove the battery compartment cover.
2. Insert the batteries, matching the polarities.
3
4
NOTE Batteries should not be exposed to excessive
heat such as sunshine or fire.
1. RESET: Reset unit to default settings
2. EU / UK Switch (RTHN318D sensor only)
3. Channel Switch
4. Double sided adhesive tape
5. Wall mount hole
REMOTE SENSOR INSTALLATION
1. Slide open the battery door.
2. Slide channel switch to channel 1.
3. Select EU/UK. (RTHN318D only)
4. Insert the battery, matching the polarities (+ / -).
5. Press RESET after each battery change.
6. Close the battery door.
6. Battery compartment
7. Press and hold UP and DOWN on main unit
3
BAR610P_M_EN_R3.indd
3
12/9/08 17:55:44
Download from Www.Somanuals.com. All Manuals Search And Download.
to initiate search and start receiving time and
temperature data from the sensor.
The sensor reception icon shows the status:
For best results:
•
•
•
Place the sensor within 30 m (100 ft) of the main
unit.
Place the sensor out of direct sunlight and
moisture.
Position the sensor so that it faces the main unit,
minimizing obstructions such as doors, walls and
furniture.
ICONS
MEANING
Main unit is searching
for sensor(s)
A
sensor channel
•
•
Place the sensor in a location with a clear view to
the sky, away from metallic / electronic objects.
Position the sensor close to the main unit during
cold winter months as below-freezing temperatures
may affect battery performance and signal
transmission.
has been found and
logged on
No sensor found
NOTE After every sensor initialisation, the main unit
may take up to 30 minutes to receive the time from
the sensor.
TIP The transmission range may vary depending
on many factors. You may need to experiment with
various locations to get the best results.
NOTE Use alkaline batteries for longer usage and
consumer grade lithium batteries in temperatures
below freezing.
8. Secure the sensor in the desired location using the
wall mount hole or double sided adhesive tape.
CLOCK
CLOCK RECEPTION
This product is designed to synchronize its clock
automatically with
a
clock signal received from
provided remote sensor.
To enable / disable signal reception:
Press and hold UP to enable or DOWN to disable
signal reception.
4
BAR610P_M_EN_R3.indd
4
12/9/08 17:55:46
Download from Www.Somanuals.com. All Manuals Search And Download.
US (BAR610PA only) set the clock to:
NOTE Reception takes 2-10 minutes. If the signal is
weak, it can take up to 24 hours to get a valid signal.
0 for Pacific time
+2 for Central time
+1 for Mountain time
+3 for Eastern time
Clock signal reception indicator:
STRONG SIGNAL
WEAK / NO SIGNAL
ALARM
To set the alarm:
1. Slide ALARM ON-OFF switch to ON.
2. Press and hold ALARM SET.
3. Press UP / DOWN to change the settings.
4. Press ALARM SET to confirm.
NOTE Clock reception is dependent on the successful
transmission of data from remote sensor. If is
displayed, press RESET on sensor and press UP and
DOWN together on the main unit and ensure sensor
has been successfully logged.
indicates alarm is on.
To activate / deactivate alarm:
•
Slide ALARM ON-OFF switch to ON / OFF.
MANUALLY SET CLOCK
To silence the alarm:
To set the clock manually, disable the clock signal
reception first.
1. Press and hold CLOCK SET.
2. Press UP / DOWN to change the settings.
3. Press CLOCK SET to confirm.
•
Press SNOOZE to silence it for 8 minutes
OR
•
Press any key to turn the alarm off and activate it
again after 24 hours.
The settings order is: time zone, 12/24 hr format, hour,
minute.
BAR610P / BAR610PU: Time zone offset sets the
clock +/- 23 hours from the received clock signal time.
NOTE If you enter + 1 in the time offset setting, this will
give you your local time plus one hour. If you are in the
5
BAR610P_M_EN_R3.indd
5
12/9/08 17:55:47
Download from Www.Somanuals.com. All Manuals Search And Download.
To deactivate projection:
Slide PROJECTION switch to OFF mode.
WEATHER FORECAST
•
This product forecasts the next 12 to 24 hours of
weather within a 30-50 km (19-31 mile) radius with a
75% accuracy.
To rotate image:
Turn PROJECTION DIRECTION wheel.
•
To flip projected image by 180°:
Press SNOOZE twice.
Sunny
•
Partially Cloudy
Cloudy
To focus image:
Turn FOCUS wheel.
•
NOTE If projection is illuminated, do not look directly
into the projector.
Rainy
AUTO-ROTATING SCREEN
TEMPERATURE
This special feature gives the user the choice of placing
the unit horizontally or vertically (3 dimensional options)
to suit user’s living environment and accommodate
individual style.
To toggle temperature unit:
•
Press °C / °F.
PROJECTION
BACKLIGHT
This unit projects time and outdoor temperature
information for your convenience.
To activate backlight:
•
Press SNOOZE.
For continuous projection:
•
Slide PROJECTION switch to ON when adaptor is
connected, to enable / disable.
RESET
Press RESET to return to the default settings.
To project time and temperature:
•
Press SNOOZE when PROJECTION switch is in
OFF mode.
6
BAR610P_M_EN_R3.indd
6
12/9/08 17:55:49
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
MAIN UNIT
PRECAUTIONS
•
Where there is excess electrostatic discharge, the
unit may reset itself to default settings. User will be
required to set the unit again.
TYPE
DESCRIPTION
•
•
•
•
•
•
•
•
Do not subject the unit to excessive force, shock,
dust, temperature or humidity.
Do not cover the ventilation holes with any items
such as newspapers, curtains etc.
Do not immerse the unit in water. If you spill liquid
over it, dry it immediately with a soft, lint-free cloth.
Do not clean the unit with abrasive or corrosive
materials.
Do not tamper with the unit’s internal components.
This invalidates the warranty.
Only use fresh batteries. Do not mix new and old
batteries.
Images shown in this manual may differ from the
actual display.
When disposing of this product, ensure it is
collected separately for special treatment and not
as normal household waste.
L x W x H
194 x 136 x 49 mm
(7.71 x 5.35 x 1.93 in)
Weight
Power
670g (23.63 oz) without battery
6V AC adaptor
3 x UM-4 (AAA) 1.5V batteries
REMOTE RF CLOCK THERMO SENSOR
TYPE
DESCRIPTION
L x W x H
64 x 25 x 98 mm
(2.52 x 0.98 x 3.86 in)
Weight
80 g (2.8 oz) without battery
Temperature range -20°C to 60°C (-4°F to 140°F)
•
Placement of this product on certain types of
wood may result in damage to its finish for which
Oregon Scientific will not be responsible. Consult
the furniture manufacturer’s care instructions for
information.
The contents of this manual may not be reproduced
without the permission of the manufacturer.
Do not dispose old batteries as unsorted municipal
waste. Collection of such waste separately for
special treatment is necessary.
Resolution
0.1°C (0.2°F)
433 MHz
Signal frequency
Transmission range 30 m (98 ft) unobstructed
•
•
No. of channels
Power
5
1 x UM-3 (AA) 1.5 V batteries
7
BAR610P_M_EN_R3.indd
7
12/9/08 17:55:49
Download from Www.Somanuals.com. All Manuals Search And Download.
•
Please note that some units are equipped with
a battery safety strip. Remove the strip from the
battery compartment before first use.
COUNTRIES RTTE APPROVAL COMPLIED
NOTE The technical specifications for this product and
the contents of the user manual are subject to change
without notice.
All EU countries, Switzerland CH
N
and Norway
NOTE Features and accessories will not be available
in all countries. For more information, please contact
your local retailer.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired
operation.
ABOUT OREGON SCIENTIFIC
more about Oregon Scientific products. If you’re in
the US and would like to contact our Customer Care
department directly, please visit:
www2.oregonscientific.com/service/support.asp
For international inquiries, please visit:
WARNING Changes or modifications not expressly
approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
www2.oregonscientific.com/about/international.asp
NOTE This equipment has been tested and found
to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against
harmful interference in a residential installation.
EU-DECLARATION OF CONFORMITY
Hereby, Oregon Scientific, declares that this Smart
Weather Station With auto-rotating screen (Model:
BAR610P / BAR610PA / BAR610PU) is in compliance
with the essential requirements and other relevant
provisions of Directive 1999/5/EC. A copy of the signed
and dated Declaration of Conformity is available on
request via our Oregon Scientific Customer Service.
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
8
BAR610P_M_EN_R3.indd
8
12/9/08 17:55:50
Download from Www.Somanuals.com. All Manuals Search And Download.
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment
off and on, the user is encouraged to try to correct
the interference by one or more of the following
measures:
With auto-rotating screen
IDT Technology Limited
Block C, 9/F, Kaiser Estate,
Phase 1, 41 Man Yue St.,
Hung Hom, Kowloon,
Hong Kong
Manufacturer:
Address:
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment
and receiver.
is in conformity with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received,
including interference that may cause undesired
operation.
•
•
Connect the equipment into an outlet on
circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio / TV
technician for help.
a
DECLARATION OF CONFORMITY
The following information is not to be used as contact
for support or sales. Please visit our website at www2.
oregonscientific.com/service for all enquiries.
We
Name:
Address:
Oregon Scientific, Inc.
19861 SW 95th Ave.,Tualatin,
Oregon 97062 USA
Telephone No.:
1-800-853-8883
declare that the product
Product No.:
BAR610P / BAR610PA /
BAR610PU
Product Name:
Smart Weather Station
9
BAR610P_M_EN_R3.indd
9
12/9/08 17:55:50
Download from Www.Somanuals.com. All Manuals Search And Download.
|