| INSTRUCTION MANUAL   5 series   Blood Pressure Monitor   Model BP742   Download from Www.Somanuals.com. All Manuals Search And Download.   INTRODUCTION   ® ® Thank you for purchasing the OMRON BP742 IntelliSense Automatic Blood   Pressure Monitor.   Fill in for future reference.   DATE PURCHASED: __________________   SERIAL NUMBER: ____________________   • Staple your purchase receipt here   • Register your product on-line at   Your new digital blood pressure monitor uses the oscillometric method of blood   pressure measurement. This means the monitor detects your blood’s movement through   your brachial artery and converts the movements into a digital reading. An   oscillometric monitor does not need a stethoscope so the monitor is simple to use.   The BP742 comes with the following components:   • Monitor • Standard Adult Arm Cuff • 4 “AA” Alkaline Batteries   • Instruction Manual printed in English and Spanish • Quick Start Guide   ® The BP742 IntelliSense Automatic Blood Pressure Monitor is intended for home use.   SAVE THESE INSTRUCTIONS   Download from Www.Somanuals.com3. All Manuals Search And Download.   SAFETY INFORMATION   To assure the correct use of the product, basic safety measures should always be   followed including the warnings and cautions listed in this instruction manual.   SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL   Indicates a potentially hazardous situation which, if not avoided,   could result in death or serious injury.   WARNING   Indicates a potentially hazardous situation which, if not avoided,   may result in minor or moderate injury to the user or patient or   damage to the equipment or other property.   CAUTION   OPERATING THE DEVICE   Contact your physician for specific information about your blood pressure.   Self-diagnosis and treatment using measured results may be dangerous. Follow the   instructions of your physician or licensed healthcare provider.   The monitor is not intended to be a diagnostic device.   If battery fluid should get in your eyes, immediately rinse with plenty of clean   water. Contact a physician immediately.   Read all of the information in the instruction manual and any other literature in the   box before operating the unit.   This device is intended for use in measuring blood pressure and pulse rate in the   adult population. Do not use this device on infants or persons who cannot express   their intentions.   Read the Special Conditions section of the instruction manual if your systolic   pressure is known to be more than 220 mmHg. Inflating to a higher pressure than   necessary may result in bruising where the cuff is applied.   Operate the device only as intended. Do not use the device for any other purpose.   Dispose of the device, components and optional accessories according to applicable   local regulations. Unlawful disposal may cause environmental pollution.   Download from Www.Somanuals.com. All Manuals Search And Download.   4 SAFETY INFORMATION   Do not use a cellular phone near the device. It may result in an operational failure.   Use only Omron authorized parts and accessories. Parts and accessories not   approved for use with the device may damage the unit.   Use only 1.5 V “AA” alkaline batteries with this device. Do not use other types of   batteries. This may damage the unit   CARE AND MAINTENANCE   Do not subject the monitor to strong shocks, such as dropping the unit on the floor.   Do not submerge the device or any of the components in water.   Store the device and the components in a clean, safe location.   Changes or modification not approved by the manufacturer will void the user   warranty. Do not disassemble or attempt to repair the unit or components.   Download from Www.Somanuals.com5. All Manuals Search And Download.   BEFORE TAKING A MEASUREMENT   To ensure a reliable reading follow these recommendations:   1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes   before taking a measurement. Rest for at least 15 minutes before taking the   measurement.   2. Stress raises blood pressure. Avoid taking measurements during stressful times.   3. Measurements should be taken in a quiet place.   4. Remove tight-fitting clothing from your left arm.   5. Sit on a chair with your feet flat on the floor. Rest your left arm on table so that the   cuff is at the same level as your heart.   6. Remain still and do not talk during the measurement.   7. Wait 2-3 minutes between measurements. The wait time allows the arteries to return   to the condition prior to taking the blood pressure measurement. You may need to   increase the wait time depending on your individual physiological characteristics.   8. Keep a record of your blood pressure and pulse readings for your physician. A   single measurement does not provide an accurate indication of your true blood   pressure. You need to take and record several readings over a period of time. Try to   measure your blood pressure at the same time each day for consistency.   Download from Www.Somanuals.com. All Manuals Search And Download.   6 KNOW YOUR UNIT   Main Unit:   Display   Battery compartment   START/STOP button   Air Jack   USER ID   Selection Switch   AC adapter Jack   Up/Down (   ) buttons   Date/Time setting (   button   ) Components:   Automatic   Blood Pressure Monitor   5 series   Air tube   Air plug   Model BP742   5 Series Arm Blood Pressure   Monitor   BP742   Instruction   Manual   Quick Start   Guide   Standard Adult Arm Cuff   UNIT DISPLAY   Systolic blood pressure   Diastolic blood pressure   Heartbeat symbol /   Memory symbol   (Displayed when viewing   values stored in memory)   Movement error symbol   Hypertension Indicator   Pulse display   Deflation symbol   User ID symbol (A/B)   Irregular Heartbeat symbol   Date/Time Display   Battery low indicator   Download from Www.Somanuals.com7. All Manuals Search And Download.   DISPLAY SYMBOLS   IRREGULAR HEARTBEAT SYMBOL (   ) When the monitor detects an irregular rhythm two or more times during the   measurement, the Irregular Heartbeat Symbol (   measurement values.   ) will appear on the display with the   An irregular heartbeat rhythm is defined   Normal Heartbeat   as a rhythm that is more than 25%   Pulse   slower or 25% faster from the average   rhythm detected while the monitor is   Blood   pressure   measuring the systolic and diastolic   blood pressure.   Irregular Heartbeat   If the irregular heartbeat symbol (   displays with your measurement results,   ) Short Long   Pulse   we recommend you consult your   Blood   pressure   physician. Follow the directions of your   doctor.   MOVEMENT ERROR SYMBOL (   ) The Movement Error Symbol (   ) is displayed if you move your body during the   measurement. Please remove the arm cuff, and wait 2-3 minutes. Reapply the arm cuff   and take another measurement.   HEARTBEAT SYMBOL/HYPERTENSION INDICATOR (   TAKING A MEASUREMENT   ) The Heartbeat Symbol ( ) flashes on the display during the measurement. The   Heartbeat Symbol ( ) flashes at every heartbeat.   When the measurement is complete, the Heartbeat Symbol ( ) flashes on the   display with your blood pressure and pulse rate if the reading is above 135 for the   Systolic Blood Pressure value and/or above 85 for the Diastolic Blood Pressure   value.   USING THE MEMORY FUNCTION   The Heartbeat Symbol ( ) flashes when the blood pressure reading stored in the   memory is above 135 for the Systolic Blood Pressure value and/or above 85 for the   Diastolic Blood Pressure value.   Download from Www.Somanuals.com. All Manuals Search And Download.   8 DISPLAY SYMBOLS   The American Heart Association recommends the following guideline for upper limit   of normal for home blood pressure readings:   AHA Home Guideline for Upper Limit of Normal BP   Systolic Blood Pressure   Diastolic Blood Pressure   135 mmHg   85 mmHg   This is a general guideline because blood pressure depends on age and morbidity.   The AHA recommends a lower home blood pressure goal for certain patients,   1 including diabetic patients, pregnant women, and patients with renal failure .   WARNING   The monitor is not intended to be a diagnostic device.   WARNING   Contact your physician for specific information about your blood pressure.   Self-diagnosis and treatment using measured results may be dangerous.   Follow the instructions of your physician or licensed healthcare provider.   Omron Healthcare recommends you contact your physician if the Heartbeat Symbol  ( ) flashes on the display with your measurement values.   1American Heart Association Scientific Statement 2004   Download from Www.Somanuals.com9. All Manuals Search And Download.   BATTERY INSTALLATION   CAUTION   Use only 1.5V “AA” alkaline batteries with this device.   1. Press the indicator on the battery cover and �   slide the cover off in the direction of the arrow.   2. Install 4 “AA” size batteries so the + (positive) and - (negative) polarities match the polarities of �   the battery compartment as indicated.   3. Replace the battery cover.   Download from Www.Somanuals.com. All Manuals Search And Download.   10   BATTERY INSTALLATION   BATTERY REPLACEMENT   Low Battery Indicator   When the Low Battery Indicator appears on the display, turn the monitor off and   remove all the batteries. Replace with four new batteries at the same time. Long-life   alkaline batteries are recommended.   WARNING   If battery fluid should get in your eyes, immediately rinse with   plenty of clean water. Contact a physician immediately.   NOTES: • Turn the unit off before replacing the batteries. If the batteries are removed   while the unit is still on, the date and time will be reset to that of the   previous use. However, the measurement results are not deleted.   • When the batteries are replaced, you may need to reset the date and time. If   “-:--” appears on the display, refer to “Setting the Date and Time”.   • The supplied batteries may have a shorter life.   CAUTION   Dispose of the device, components and optional accessories according to   applicable local regulations. Unlawful disposal may cause environmental   pollution.   Download from Www.Somanuals.co1m1. All Manuals Search And Download.   SETTING THE DATE AND TIME   Set the monitor to the current date and time before taking a measurement for the first   time. If the date and time has not been set, the measurement values are stored without   any date or time information.   1. TO START THE SETTING   Press the Date/Time Setting button ( ) to adjust the date and time.   The year flashes on the display   . 2. SETTING THE YEAR   The year can be set between 2010 and 2040. When the   display reaches 2040, it will return to 2010.   Press the Up button ( ) to advance by increments of one   year.   Press the Date/Time Setting button ( ) to set the current   year.   The month flashes on the display.   NOTES: • Press the Down button ( ) to decrease the   date and time values by increments of one.   • Press and hold the button to increase or   decrease the date and time values faster.   Download from Www.Somanuals.com. All Manuals Search And Download.   12   SETTING THE DATE AND TIME   3. SETTING THE MONTH   Press the Up button ( ) to advance by increments of one month.   Press the Date/Time Setting button ( ) to set the current   month.   The day flashes on the display.   4. SETTING THE DAY   Press the Up button ( ) to advance by increments of   one day.   Press the Date/Time Setting button ( ) to set the current   day.   The hour flashes on the display.   5. SETTING THE HOUR   The time is set using AM or PM.   Press the Up button ( ) to advance by increments of   one hour.   Press the Date/Time Setting button ( ) to set the current   hour.   The minute flashes on the display.   6. SETTING THE MINUTE   Press the Up button ( ) to advance by increments of one   minute.   Press the Date/Time Setting button ( ) to set the minute setting.   7. TO TURN THE MONITOR OFF   Press the START/STOP button.   NOTE: The monitor will automatically turn off five minutes after the minute has   been set.   Download from Www.Somanuals.co1m3. All Manuals Search And Download.   APPLYING THE ARM CUFF   CAUTION   Read all of the information in the instruction manual and any other   literature in the box before operating the unit.   CAUTION   This device is intended for use in measuring blood pressure and   pulse rate in the adult population. Do not use this device on infants   or persons who cannot express their intentions.   APPLYING THE CUFF ON THE LEFT ARM   1. Make sure the air plug is securely inserted   in the main unit.   2. Remove tight-fitting clothing from your upper   arm.   Download from Www.Somanuals.com. All Manuals Search And Download.   14   APPLYING THE ARM CUFF   3. Apply the cuff to your left upper arm so  Left Arm   1/2 inch (1 - 2 cm)   the arrow is centered on the inside of your arm  and aligned with your middle finger.  The air tube runs down the inside of your arm.  The bottom of the cuff should be  Arrow   Air Tube   approximately 1/2 “ above your elbow.   4. Wrap the cuff firmly in place around your  arm using the cloth fastening.   APPLYING THE CUFF ON THE RIGHT ARM   When taking a measurement using the right arm, use this instruction for Step 3.   Right Arm   Apply the cuff to your right upper arm so the   arrow and the air tube runs along the inside   of your arm. The bottom of the cuff should be  approximately 1/2 “ above your elbow.   Arrow   NOTE: Be careful not to rest your arm on the air tube. This will restrict the flow of air   to the cuff.   Download from Www.Somanuals.co1m5. All Manuals Search And Download.   TAKING A MEASUREMENT   1. Press the START/STOP button to turn the monitor on.   All symbols appear on the display.   2. Select your USER ID (A or B).   3. Sit on a chair with your feet flat on the floor.   Place your arm on a table so the cuff is level   with your heart.   Keep still and do not talk during measurement.   4. Press the START/STOP button.   The cuff starts to inflate automatically. As the cuff inflates, the monitor automatically   determines your ideal inflation level.   Remain still and do not move your arm until the entire measurement process is completed.   NOTE: To stop the inflation or measurement, push the START/STOP button. The   monitor will stop inflating, start deflating, and will turn off.   Download from Www.Somanuals.com. All Manuals Search And Download.   16   TAKING A MEASUREMENT   5. Inflation stops automatically and the measurement is started.   As the cuff deflates, decreasing numbers appear on the display and the Heartbeat   Symbol ( ) flashes.   6. When the measurement is complete, the arm cuff completely   deflates. Your blood pressure and pulse rate are displayed.   7. Press the START/STOP button to turn the monitor off.   NOTE: The monitor will automatically turn off after   five minutes.   Download from Www.Somanuals.co1m7. All Manuals Search And Download.   TAKING A MEASUREMENT   SPECIAL CONDITIONS   CAUTION   Inflating to a higher pressure than necessary may result in bruising where   the cuff is applied.   If your systolic pressure is known to be more than 220 mmHg, press and   hold the START/STOP button until the monitor inflates 30 to 40 mmHg   higher than your expected systolic pressure.   NOTES: • Do not apply more pressure than necessary.   • The monitor will not inflate above 299 mmHg.   When the measurement is complete, the arm cuff completely deflates.   Your blood pressure and pulse rate are displayed.   Download from Www.Somanuals.com. All Manuals Search And Download.   18   USING THE MEMORY FUNCTION   The monitor is designed to store the blood pressure and the pulse rate in the memory   for two people (USER A and USER B) every time a measurement is completed.   The monitor automatically stores up to 30 sets of measurement values (blood pressure   and pulse rate) for each user (A and B). When 30 sets of measurement values are   stored, the oldest record is deleted to save the most recent values.   TO DISPLAY THE MEASUREMENT VALUES   1. Press the START/STOP button to turn the monitor on.   2. Select your USER ID (A or B).   3. Press the Up button ( ) to display the most recent set of measurement values on   the screen.  Press the Down button ( ) to display the oldest set of measurement values.   Download from Www.Somanuals.co1m9. All Manuals Search And Download.   USING THE MEMORY FUNCTION   NOTES: • The measurement value number is displayed   briefly in the Pulse Display area when you press   the Up/Down buttons (   ).   • The date and time are alternately displayed with   the measurement values.   • If the date and time are not set, “-:--” is displayed   with the measurement values.   • Press the button repeatedly to display the next   values.   • Press and hold the button to display the values   faster.   Alternating   display   TO DELETE ALL VALUES STORED IN THE MEMORY   The values stored in the memory are deleted by USER ID.   You cannot partially delete values stored in the memory. All values for   the user you select will be deleted.   1. Press the START/STOP button to turn the monitor on.   2. Select your USER ID (A or B).   3. While holding the Down button ( ), press the START/STOP button down for   more than five seconds until the display appears as it does in the following   illustration.   4. Press the START/STOP button to turn the monitor off.   NOTE: The monitor will automatically turn off after five minutes.   Download from Www.Somanuals.com. All Manuals Search And Download.   20   CARE AND MAINTENANCE   To keep your digital blood pressure monitor in the best condition and protect the unit   from damage, follow the directions listed below:   Do not forcefully bend the arm cuff or air tube. Do not fold tightly.   Clean the monitor with a soft dry cloth.   Do not use any abrasive or volatile cleaners.   Do not attempt to clean the cuff.   CAUTION   Do not submerge the device or any of the components in water. Do   not subject the monitor to extreme hot or cold temperatures,   humidity or direct sunlight.   CAUTION   Store the device and the components in a clean, safe location.   CAUTION   Do not subject the monitor to strong shocks, such as dropping the unit on the floor.   Remove the batteries if the unit will not be used for three months or longer. Always   replace all the batteries with new ones at the same time.   Use the unit consistent with the instruction provided in this manual.   Use only authorized parts and accessories.   Use the unit in a manner consistent with the instructions provided in this manual.   CAUTION   Use only Omron authorized parts and accessories. Parts and accessories   not approved for use with the device may damage the unit.   CAUTION   Changes or modification not approved by the manufacturer will void the user   warranty. Do not disassemble or attempt to repair the unit or components.   Download from Www.Somanuals.co2m1. All Manuals Search And Download.   ERROR INDICATORS   SYMBOL   CAUSE   CORRECTION   Take another measurement and   remain still until the measurement   is complete.   Monitor could not   detect pulse wave.   Cuff under-inflated.   Cuff not applied   correctly.   Remove the arm cuff.   Read “Taking a Measurement”.   Wait 2-3 minutes.   Cuff over-inflated.   Device error.   Take another measurement.   Contact Customer Service.   Movement during �   measurement.   Keep still and take another   measurement.   Remove the arm cuff. Wait 2-3   minutes and then take another   measurement. Repeat the steps in   section “Applying the Arm Cuff.”   If this error continues to appear,   contact your doctor.   Irregular or weak pulses are detected.   Replace the four batteries.   Refer to “Battery Installation.”   Batteries are exhausted.   Download from Www.Somanuals.com. All Manuals Search And Download.   22   TROUBLESHOOTING TIPS   PROBLEM   CAUSES AND SOLUTIONS   Replace all four batteries with new ones.   Check the battery installation for proper placement   of the battery polarities.   No power.   No display appears on the unit.   Blood pressure varies constantly. Many factors   including stress, time of day, how you wrap the   cuff, may affect your blood pressure.  Measurement values appear too   high or too low.   Review the sections “Before Taking a   Measurement” and “Taking a Measurement”.   Download from Www.Somanuals.co2m3. All Manuals Search And Download.   FCC STATEMENT   Note:   POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only)   This product has been tested and found to comply with the limits for a Class B digital   device, pursuant to part 15 of the FCC rules.   These limits are designed to provide reasonable protection against harmful interference   in a residential installation. The product generates, uses, and can radiate radio   frequency energy and, if not installed and used in accordance with the instructions,   may cause harmful interference to radio communications. However, there is no   guarantee that interference will not occur in a particular installation. If the product does   cause harmful interference to radio or television reception, which can be determined by   turning the product on and off, the user is encouraged to try to correct the interference   by one or more of the following measures:   • Reorient or relocate the receiving antenna.   • Increase the separation between the product and the receiver.   • Connect the product into an outlet on a circuit different from that to which the   receiver is connected.   • Consult the dealer or an experienced radio/TV technician for help.   POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for Canada only)   This digital apparatus does not exceed the Class B limits for radio noise emissions   from digital apparatus as set out in the interference-causing equipment standard entitled   “Digital Apparatus”, ICES-003 of the Canadian Department of Communications.   Cet appareil numérique respecte les limites de bruits radioeléctriques applicables aux   appareils numériques de Clase B prescrites dans la norme sur le materiel brouilleur:   “Appareils Numériques”, ICES-003 édictée par le minister des communications.   Changes or modifications not expressly approved by the party responsible for   compliance could void the user’s authority to operate the equipment.   Download from Www.Somanuals.com. All Manuals Search And Download.   24   LIMITED WARRANTIES   ® Y our BP742 IntelliSense Automatic Blood Pressure Monitor, excluding the arm cuff, is   warranted to be free from defects in materials and workmanship appearing within 2 years from   the date of purchase, when used in accordance with the instructions provided with the monitor.   The arm cuff is warranted to be free from defects in materials and workmanship appearing   within one year from the date of purchase when the monitor is used in accordance with the   instructions provided with the monitor. The above warranties extend only to the original retail   purchaser.   We will, at our option, repair or replace without charge any monitor or arm cuff covered by the   above warranties. Repair or replacement is our only responsibility and your only remedy under   the above warranties.   To obtain warranty service contact Customer Service by calling 1-800-634-4350 for the address   of the repair location and the return shipping and handling fee.   Enclose the Proof of Purchase. Include a letter, with your name, address, phone number, and   description of the specific problem. Pack the product carefully to prevent damage in transit.   Because of possible loss in transit, we recommend insuring the product with return receipt   requested.   THE FOREGOING IS THE SOLE WARRANTY PROVIDED BY OMRON IN   CONNECTION WITH THIS PRODUCT, AND OMRON HEREBY DISCLAIMS ANY   OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING IMPLIED   WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR   PURPOSE. IMPLIED WARRANTIES AND OTHER TERMS THAT MAY BE   IMPOSED BY LAW, IF ANY, ARE LIMITED IN DURATION TO THE PERIOD OF   THE ABOVE EXPRESS WARRANTY.   OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER SPECIAL,   INCIDENTAL, CONSEQUENTAIL OR INDIRECT COSTS, EXPENSES OR   DAMAGES.   This warranty provides you with specific legal rights, and you may have other rights that vary by   jurisdiction. Because of special local requirements, some of the above limitations and exclusions   may not apply to you.   FOR CUSTOMER SERVICE   Visit our web site at:   Call toll free:   1-800-634-4350   Download from Www.Somanuals.co2m5. All Manuals Search And Download.   SPECIFICATIONS   Model:   Display:   Measurement Range:   Accuracy/Calibration:   Inflation:   Deflation:   Rapid Air Release:   Measurement Method:   Power Source:   Battery Life:   Operating Temperature   /Humidity:   Storage Temperature   /Humidity/Air Pressure:   Main Unit Weight:   Main Unit Dimensions:   Cuff Size:   Cuff Circumference:   Memory:   Contents:   Download from Www.Somanuals.com. All Manuals Search And Download.   26   SPECIFICATIONS   Optional Accessories:   NOTE: These specifications are subject to change without notice.   Download from Www.Somanuals.co2m7. All Manuals Search And Download.   Omron Healthcare, Inc.   1200 Lakeside Drive   Bannockburn, IL 60015   www.omronhealthcare.com   Copyright © 2010 Omron Healthcare, Inc.   Made in China   5329417-5A   Download from Www.Somanuals.com. All Manuals Search And Download.   |