Read and Understand this Catalog
Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have any
questions or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or
other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
NS12-V2 NS10-V2 NS8-V2
12-inch Model
10-inch Model
8-inch Model
NS5-V2 NSH5
5-inch Model
5-inch Hand-held Model
Programmable Terminals
NS-CXDC1-V1
LIMITATIONS OF LIABILITY
Ver. 1
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT,
WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
NS-series Screen Creation Software
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
Installing a Navigator: A Totally New Concept in
Programmable Terminals
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS
UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND
MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the
product in the customer's application or use of the product.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be
used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY
RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your
OMRON representative at any time to confirm actual specifications of purchased product.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a
warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements.
Actual performance is subject to the OMRON Warranty and Limitations of Liability.
Printed on 100%
Recycled Paper
Note: Do not use this document to operate the Unit.
OMRON ELECTRONICS LLC
OMRON Corporation
Authorized Distributor:
1 East Commerce Drive, Schaumburg,
IL 60173 U.S.A.
Control Devices Division H.Q.
Shiokoji Horikawa, Shimogyo-ku,
Tel:(1)847-843-7900/Fax:(1)847-843-8568
Kyoto, 600-8530
Japan
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue,
#11-01, UE Square,
Tel:(81)75-344-7109
Fax:(81)75-344-7149
Singapore 239920
Tel:(65)6835-3011/Fax:(65)6835-2711
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD Hoofddorp
The Netherlands
Tel:(31)2356-81-300/
Fax:(31)2356-81-388
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120 China
Tel:(86)21-5037-2222/Fax:(86)21-5037-2200
NSH5
NS5-V2
5-inch Model
NS8-V2
NS10-V2
10-inch Model
NS12-V2
12-inch Model
5-inch
8-inch Model
Hand-held
Model
Cat. No. V078-E1-09
Printed in Japan
0206-1M
Note: Specifications subject to change without notice.
NS Series
Download from Www.Somanuals.com. All Manuals Search And Download.
We are always trying to
provide solutions that will
give the highest added
value to your system.
We strive to solve on-site
problems with our
Make it More Simple
Seamless
The NS is moving to the next stage, from a touch screen
to an advanced machine management tool.
solutions instead of just
providing touch screen
functions. That is what
OMRON is focused on.
It's convenient
but…
Machine Management
Touch Screen Operation
Switch Operation
Smart
Turning switches into Touch Screens brings
enhancements, such as minimum wiring,
space savings, and improved local operation
efficiency. Moreover, OMRON works to
minimize the customer's energy expenditure
from machine design to troubleshooting.
OK!
It's convenient
but…
Previous PT
Previous zone
New zone
NS Enters a New Zone
From PLC Memory Allocation
to Device Access
NS Series
The NS Series achieves
flexible data access to a
variety of devices. It
enables operators to reach
the devices on the network
including Special I/O Units,
intelligent devices, and
PLCs.
Previous PTs shared data that was
allocated in advance to specific words in
the CPU Unit, and they were used to
assist with device operations, and to
display error locations, and
countermeasures.
Special I/O Units
PLC
PT
CPU Unit
PLC
Network
Example: DeviceNet
It's time for
switch inspection.
Allocated data
Sharing allocated
data with CPU Unit
Intelligent devices
Example: DRT2-series Smart Slave
The cylinder
speed is strange.
Smart Active Parts
(Functional software parts)
Example: Monitoring maintenance information
for various DeviceNet Smart Slave models
2
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Don't you have these problems?
PTs as a Machine Navigator
NS-series PTs navigate all areas of machine operation,
from daily operation to error recovery.
The Smart Active Parts are the solution.
Previous
Using all of the device-specific
personal computer tools at startup is
Various device-specific tools
okay, but using the personal
computer tools for error recovery
during operation is overly difficult.
Peripheral Devices for PLC
Network control
Temperature settings and
monitoring tools
Personal computer tools
Setting tool for position control
Wouldn't it be simpler to use the PT instead?
With an NS-series PT, just drag and drop Smart Active Parts to customize the interface
for your machine.
NS-series PTs provide Smart Active Parts that allow direct data access
to a variety of devices.
Only with NS!
PLC System Objects
The PT is traditionally a
terminal that exchanges data in
Previously
a CX-Programmer
was required.
Just
attach to
a screen.
allocated areas with the PLC's CPU
Unit. The internal and external control
of a PLC with only this type of data
exchange is, however, difficult.
A NS-series PT, however, uses
communications functions and Smart
Active Parts to incorporate
software computer functions to
operate as a Device Navigator.
Position Control Objects
Ensures easy
screen settings
in the NCF.
NS Series
Previous
Example: RS-232C
Colors and
sizes can be
changed.
NS Series
Device operations
Example: Ethernet
PT
NS: Device Navigator
Displaying device error locations
DeviceNet Objects
Devices accessed without a program.
Previously
Example: DeviceNet
a DeviceNet
Personal computer tool
Configurator was
required.
Displaying countermeasures
Internal device monitoring
and resetting
(Supporting recovery methods)
Temperature Controller Parts
ThermoTool was
required in the
With version 2 PTs (V2 suffix in model number), hardware functions are upgraded.
past.
Large Capacity
NS8-V2/NS10-V2/NS12-V2: 60 MB
(-V1: 20 MB, same as before)
NS5-V2: 20 MB
Increased Visibility
NS8-V2: Increased from 8.0 to 8.4 inches
NS5-V2(STN)/NS12: Wider field of vision
Refer to page 15 of this catalog to see the wide variety of Smart
Active Parts.
The Smart Active Parts are accessed by selecting Tools
Use Library from the menu bar of the CX-Designer.
Note: The NS5-V1 has a capacity of 6 MB.
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Multi-language Terminal
Do you have the following problems when starting
Machine Localization with PTs
the system or when errors occur?
Previous
A Multi-language Input Environment
Using Excel
No special PT tools are required for translation
operations.
Translations can be requested using e-mail
attachments.
Label Switching Function for Up to
16 Languages
Devices can be started with Japanese-language
screens, and then operated with screens in other
languages.
When an Error Occurs during Operation
When the System is Started
PT used for operation
after startup.
There is no way for
the PT to recover
following an error.
(Creating a screen
is quite
An error occurs,
and…
The languages can be switch to the one preferred by
the device operators.
troublesome.)
Data exchange is the main function.
English and Japanese
screen data
Japanese-language
screen
English-language
screen
Dual-language
screen data
Either a single screen
Error
Previous
data file was divided
between Japanese
and English screens,
or else multiple
screen data files
had to be created.
NS project
Because multiple labels can be
set, screen data needs to be set
only once. Multi-language
capability is simply a matter of
switching labels.
Chinese screen data
Special personal
computer tool
Chinese-language
screen
Use a dedicated computer, and you
have to wade through functionality
that is not being used or that does
not need to be reset.
Recovery can only be performed by a
specialist (i.e., an engineer).
A PT mainly exchanges data with a PLC.
Dedicated PC software is required to
gain access to other devices.
You can get multi-language support in Excel. Switching to as many as 16 languages is as
easy as switching labels.
Dual-language input in Excel by translation
companies and local
companies
Language A screen
data
Language A
Excel data
With the Smart Active Parts
NS project
CSV
Attachment
CSV
The PT can be customized according to the specifications of the device manufacturer to optimize
operation as a tool. This enables equipment maintenance by personnel other than engineers.
Language A and B
Excel data
Dual-language
screen data
Minor maintenance
Customizing and optimizing PT
can be performed on
the PT during operation.
Simply paste one of
the Smart Active
Parts! Then make only
a few device node
settings.
CSV or
Unicode
text
Attachment
CSV
NS project
Smart Active Parts
Note: Windows 2000 or XP is required
for multi-language support.
NS Series
16 languages max.
Label 15
Improved efficiency in creating maintenance screen
Setting specified
Multi-Language PT
Asian Languages
Japanese, Simplified Chinese (see note
1), Korean, and Traditional Chinese
(see note 2)
Label 0
Label 1
parameters and checking status
Only with NS!
European Languages
English, French, German, Italian,
Portuguese, Spanish, Swedish, Dutch,
Finnish, Norwegian,
Smart Active Parts
access data without
any special
Support for 17 languages
Switching to as many as
16 languages by simply
switching the labels
Basque, Catalan, and Danish
programming.
No ladder program
Multi-language conversion has become much easier!
Error Recovery Screen Example
Text and BMP files can be directly specified, so
operations such as correcting contents for recovery and
replacing diagrams and photographs can be executed
without requiring any special tools. For example, if the
recovery operation procedure is changed by system
improvements, screens can be changed by simply
replacing text and BMP files, allowing for rapid
implementation of improvements and countermeasures.
Note: Transfer tools must be used for transfers.
Create a screen like this as
a device troubleshooter.
Creating Chinese, Korean, or Other Language
Screens in Any Language Version of Windows
Multi-language CSV data
When an error occurs, rapid recovery
is critical. With the NS Series, the
following type of screen can be easily
prepared to guide on-site workers to
carry out the operations required for
recovery.
Multi-language Input (When Windows 2000 or XP is Used)
When Windows 2000 or XP is being used, Simplified
Chinese (see note),
Notification that an error
has occurred
Import
Traditional Chinese (see
note), Korean, and other
Display explanations of error
contents and methods for recovery.
(Text file direct specification)
Use diagrams to show error
locations and methods for recovery.
(Bit map file direct specification)
Display only the buttons required for
recovery operations.
language text can be input in
CX-Designer. Select the
Convenient!
desired language with Global
IME to input a different
language.
When importing screen data, the text
attributes of user-specified labels can be
applied to all other imported text. With this
function, entire Japanese text attributes
(e.g., MS Gothic in blue or other colors) can
be used in Chinese labels. Furthermore, by
using the just-fit function, long labels in
English will fit within the frame limits after
automatic font adjustment.
1
2
3
Error contents and
recovery methods are
displayed.
Error location and
Recovery operation screen
is displayed. (Only the
buttons required for
explanations of recovery
methods can be further
displayed by bit maps.
operations are shown.)
Note: Simplified Chinese: Chinese with partially simplified characters, mostly used in
Mainland China.
Note: In addition to the Troubleshooter for the machine above, there is a PLC troubleshooter for CS/CJ-series PLCs. Contact your OMRON representative for information on Troubleshooters.
Traditional Chinese: Chinese with traditional characters, mostly used in Hong
Kong and Taiwan.
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.
New functionality added in Ver. 6 extends
the ease of use of the NS-series PTs.
PT System
Ver. 6 or Higher
PT System
Ver. 6 or Higher
Improved Data Logging
Smart Active Parts greatly reduce the number of drawing and programming steps.
Number of logging points greatly increased.
Past logs can be seen.
Tool Functions Provided with Smart Active Parts
For example, the PT can log data at 2-second
intervals 24 hours a day (for a 43,200-point log).
You may want to see logs saved in the past in a
Memory Card on the screen. This is possible with
the NS Series.
Log data in a Memory Card can be read on the screen with the read
file button. A list of files with time stamps will appear on the screen.
By selecting the desired file, the past log in the Memory Card can be
read.
All you need to do is select the required Smart Active
Part in the CX-Designer and drag & drop it on the
screen see page 5).
Smart Active Parts not only reduce the number of
screen drawing and ladder programming steps, but
they also eliminate the need to debug.
Software functions are achieved on the screen
without software such as the CX- Programmer,
CX-Position, and DeviceNet Configurator.
Want to check an error or adjust
settings without any software
tools. But realization of Touch
screen and PLC program are
really time consuming.
Also, it is dangerous to use
software tools since they can do
anything. Isn't it possible to
show or set one only part of the
information?
The number of Always Log points has increased from 1,000 to 50,000
max. per line.
Drastically reduce
your programming
and development
time.
The total number of Always Log points increased from 5,000 to 50,000.
Example:
Logging 1 word and 1 address at 1-second intervals:
50,000 points, with 50,000 logging points per line.
Logging 1 word and 3 addresses at 1-second intervals:
50,000 points, with 16,666 logging points per line.
The log data files in the Memory Card
appear as shown below when the read file
button is pressed.
Make PID settings for temperature
control without connecting software.
As a setting
device for
temperature
control
The number of logging points for one line depends on the number of
logging words and the number of logging addresses. For details, refer to
the manual.
See the error log of the PLC without
connecting software.
Logging continues.
Read file button
As an error
monitor
For example, you may want to log data at
2-second intervals 24 hours a day (a 302,400-point
log). This is possible with the NS Series.
When the logging data reaches the number of preset logging points,
the logging data can be automatically saved in a Memory Card in CSV
format. After automatic saving, the logging data will be cleared.
Therefore, it will be possible to continue logging. (The Memory Card
can hold a maximum of 1,000 files.)
Standard data can be displayed in the data log.
You may want to save the present log data as
standard data in the Memory Card. This is
possible with the NS Series.
By pressing the save to file button, the displayed log data can be
saved in the Memory Card in CSV format. The saved log data can be
overlapped as standard data on the screen by pressing the read file
button. By turning the log start address ON and OFF, logged data can
be controlled to enable/disable logging.
OMRON's
Temperature
Controller
Only three parts are on the screen!
Only one single part is on the screen!
(Direct Connection)
Refer to page 15 of this catalog to see the wide variety of Smart Active Parts.
PT System
Ver. 6 or Higher
Example:
Easy screen transfer from anywhere at higher speed.
Example: Logging 1 word and 1 address at 2-second intervals with
the number of logging points set to
43,200 (i.e., at 2-second intervals for 24 hours a day).
Log start address
Standard data
Data can be transferred over USB through a single
LOG001.CSV 04/06/04 10:00
LOG002.CSV 04/06/05 10:00
LOG003.CSV 04/06/06 10:00
LOG004.CSV 04/06/07 10:00
LOG005.CSV 04/06/08 10:00
LOG006.CSV 04/06/09 10:00
LOG007.CSV 04/06/10 10:00
Memory
Card
It is possible to
make a one-week
log by
automatically
saving the data
seven times.
cable between the computer and PT. No devices for
serial RS-232C and USB conversion are required.
Moreover, USB allows high-speed screen transfer by
just connecting the cable.
Auto-
High-speed screen
transfer through
matically
saved
Most computers now have an
USB port, and no serial
RS-232C ports are provided.
USB.
You may want to transfer
screens more easily at higher
speeds.
Logging data for each
day (43,200 points) is
saved in the Memory
Card in CSV format.
Suffixes are automatically
added to file names set in
the CX-Designer.
Save to file button
Read file button
Note: Lot number 0325 or later is required
for USB screen transfer with NS-V1
models.
Screen transfers
equivalent to
Ethernet.
NS-V2 Hardware Means High Quality, High Performance, and High Capacity
Screen transfers using Memory Cards are possible
from the maintenance menu. No physical switch
operations are required on the rear panel.
Furthermore, easy operation is ensured with no wear
and tear of hardware, including the switch.
Screen transfers
using Memory
Cards are possible
High definition
USB port compatibility with commercially available printers
It is very convenient to make
backups without using a
Displays image data (BMP and JPG) beautifully.
Hard copies of screens can be printed out in color by USB-
computer. It is, however,
NS-V2: 32,000 colors
compatible printers.
USB port included as
standard equipment
troublesome to operate a DIP
switch on the back of the PT
from the
maintenance
NS5
NS8
4,096 colors
32,768 colors
General printer compatible
with USB port
Not
Supported
each time backups are required.
NS5
You may want to make backups
USB cable
Supported
NS8
periodically, but worry because
menu.
Memory
Card
NS10 32,768 colors
NS12 32,768 colors
Supported
Supported
the DIP switch pins may break.
NS10
NS12
Manufacturer: EPSON or Canon
Recommended models
Select from
the system menu.
Start downloading/
uploading.
EPSON: PM-2200C, PM-930C, PM-870C,
PM-740C, PM-900C, PM-D600,
EPSON and Canon
printers supported.
Note: NS5-SQ0 (B)-V2: STN models have 4,096 colors.
NS5-TQ0 (B)-V2: TFT models have 32,768 colors.
PM-G720, PM-G730, PX-A650,
PM-G730, PM-D600, PX-A650
Canon: BJ-M70, BJ-M40, PIXUS550i, 50i, 80i,
IP2000, IP3100, IP4100, IP4100R, IP90
The screens can be transferred from a computer in an
office through modems. The maintenance of
the screens is possible without touching the device.
Therefore, no training or engineer visits are required.
Faster drawing speed
Large-capacity image data
Even a single screen change in
a shipped machine involves a
risk, because a screen sent by
High-speed screen switching
Three times the image data capacity for standard models
See note.
Yes
NS5
V 1
V 2
e-mail needs to be transferred
Screen transfer
through modems is
RS-232C
Modem
to a person familiar with
NS8
NS5
NS8
6 MB 20 MB
20 MB 60 MB
operation. Training workers to
Yes
NS8/10/12-V1
20 MB
NS10
NS12
NS8/10/12-V2
60 MB
understand operation is a hard
now possible.
job. Or service personnel need
Yes
200-MHz RISC CPU
High-speed graphics controller
NS10 20 MB 60 MB
NS12 20 MB 60 MB
to visit the site to change
screens.
Note: The NS5
Modem
uses a different
graphic controller
from other models.
10
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Powerful Networking
The NS Series is more beautiful and user-friendly.
More beautiful
More user-friendly
Exchanging Data with a PLC over a Network (Multihost)
You can partially replace text and pictures from
your computer.
You can make beautiful screens with simple operations.
Communicating with a PLC via NT Link,
using Ethernet without Special PLC Programming
FTP (File Transfer Protocol) has been
added! Texts, lists, and recipes can be
replaced with the put/get command from
your computer! You can even replace
BMP files from your computer easily.
Using Data Links between the PT and the PLC
Beautiful BMP Parts Collection has
been newly added. Simply select
the desired part, paste it on your
Ethernet Communications without
Programming
Controller Link Interface Unit
The Controller Link is an FA network that can send and
receive large data packets flexibly and easily among
OMRON PLCs and IBM PC/AT or compatible computers. The
NS12 and NS10 PTs can be connected to the Controller Link
network easily via a Controller Link Interface Unit. When a
Controller Link network is used, data can be transferred
between multiple PLCs and NS12/NS10 PTs without writing
ladder programming to manage the communications.
Windows fonts can be used for
NS-series PTs can communicate with a CS/CJ-
series PLC (equipped with an Ethernet Unit)
through “program-free” communications just
like NT Link communications. Data is transferred
through Ethernet through a simple PLC address
and initial communications setup.
screen, and make your screens
switches and lamps Ver.5
Screens, bitmaps, text, recipe data
neat!
Auto font resizing function Ver.5
Automatically resizes fonts to the
object size.No need to adjust font
sizes manually anymore!
Furthermore, just-fit font size
adjustments have been possible
since version 6.
Personal
computer
32,768-color display
The color variation displays
pictures brilliantly!
Ethernet
Direct access
NS-series
PT
More strength in applications
CS/CJ-series
PLC
The following models, which have an RS-485 communications port and
support CompoWay/F communications, can be connected to the NS.
The NS can be connected to a Board PC. The NS can also be directly
Unit
Series and Models
Unit
Series and Models
connected to an OMRON Temperature Controller.
Modular Temperature Controllers
Temperature Controllers
E5AN/EN
Series
E5ZN
E5ZN-SCT24S
(Terminal Unit)
E5AN-
E5AN-
E5EN-
E5EN-
E5AN-
E5AN-
E5EN-
E5EN-
E5CN-
E5CN-
E5CN-
E5CN-
E5GN-
E5GN-
TC Thermocouple input
Temperature-resistance input
TC Thermocouple input
A Memory Link has been added
P
to the communications method.
It allows the NS to communicate
ControllerLink
Digital Controllers
E5AR
E5ER
E5AR- 03 -FLK
E5ER- 03 -FLK
P
T
L
T
L
Temperature-resistance input
Temperature input
Analog input
with a Board PC.
Memory link
CompoWay/F
Temperature input
Analog input
Direct access
Direct access
Direct access
Direct access
TC Thermocouple input
E5CN
Host Link CS/CJ-series,
CVM1/CV-series,
or C-series PLC
Series
P
T
L
Temperature-resistance input
Temperature input
Analog input
The NS can be directly
connected to the OMRON
CS/CJ-series PLC
NS-series PT
NS-series
PT
Temperature Controllers listed
on the right.
TC Thermocouple input
Temperature-resistance input
E5GN
Series
P
OMRON Temperature
Control Unit
PLC
NS-series
PT
System Configurations
CS/CJ-series
PLC
CS/CJ-series
PLC
Direct access
Various connections, such as 1:1, 1:2, 1:N, and M:N, are supported with Ethernet or serial connections.
PT:PLC = 1:2
PT:PLC = 1:1
SPMA (Single Port Multi Access) Function
Screen data can be transferred through the PLC from the CX-Designer to the PT connected to the PLC in series or via a network.
NS-series PT
NS-series PT
You may want to transfer screens to a PT through the PLC without changing
computer connections or to transfer a ladder program to the PLC through the PT
by using the Ethernet or Controller Link.
RS-232C
RS-232C
Communications without
programming
Communications without
programming
Communications without
programming
RS-232C
Ladder programs can be monitored or transferred from the CX-Programmer through the NS-series PT to PLCs connected to the PT
in series or via a network.
(1:1 NT Link, 1:N NT Link,
or Host Link)
To use the SPMA function through the PLC, the following
*
software and hardware versions are required.
NS-series PT: System version 3.0 or higher
NS Designer: Version 3.0 or higher or
CX-Designer: Version 1.0 or higher
CX-Programmer: Version 3.1 or higher
Screen data or Data in Memory Card
(From CX-Designer through PLC to NS-series PT)
CS/CJ-series PLC
C200HX/HG/HE PLC
SPMA
PT:PLC = M:N
PLC: Lot No. 030201 and later (Refer to the following table.)
PLC
Ladder program
(From CX-Programmer through NS-series PT to PLC)
PLC series
CPU model
CJ1H-CPU65H
CJ1H-CPU66H
CJ1G-CPU42H
CJ1G-CPU43H
CJ1G-CPU44H
CJ1G-CPU45H
CJ1M-CPU11
CJ1M-CPU12
CJ1M-CPU13
CJ1M-CPU21
CJ1M-CPU22
CJ1M-CPU23
CS1H-CPU63H
CS1H-CPU64H
CS1H-CPU65H
CS1H-CPU66H
CS1H-CPU67H
CS1G-CPU42H
CS1G-CPU43H
CS1G-CPU44H
CS1G-CPU45H
CS1D-CPU42S
CS1D-CPU44S
CS1D-CPU65S
CS1D-CPU67S
Lot number
NS-series PT
PT:PLC = 1:N
Computer
RS-232C
PLC
NS-series PT
NS-series PT
Ethernet
CJ Series
CS/CJ-
series
PLC
Peripheral
(or RS-232C)
030201
NS-series PT
NS-series PT
CS/CJ-series PLC
NS-series PT
Serial
Communications without
programming
Peripheral
bus
(Tool bus)
Ethernet
Computer
(1:N NT Link)
Serial
Serial
RS-232C
NT Link
NT Link
NS-AL002 Converter
(Converts between
RS-232C and RS-422A.)
CS/CJ-series
PLC
CS Series
030201
Controller Link
PLC
CS/CJ-series PLC
Ethernet Unit
Screen transfer
from the
Controller Link
is supported
from version 6.
Host Registration Function
It is possible to register two or more PLCs as hosts and communicate with the PLCs by specifying the host ID and address when connected via Ethernet or
Controller Link.
Serial
NT Link
CS/CJ-series PLC
NS-series PT
NS-series PT
12
13
Download from Www.Somanuals.com. All Manuals Search And Download.
The NS monitors machine status for who and how machines
are managed to help speed recover from problems.
Monitoring and Setting PLC Data
Using Video Inputs
Easily Displaying the Status of
Particular Bits in Ladder Programs
when Errors Occur
Solve with the Switch Box
function
For Operators
The NS-CA002 has joined the NS-CA001 Video Input Unit.
You may want to input moving images
from a video camera or the image
output from a Vision Sensor, arrange
them on the PT screen, and capture
(save) the images or display the capture
data on the PT.
Saving Displayed Video Images to a Memory
Card in BMP Format
Display machine
status simply.
Switch Box Function
The Switch Box Function has been added to the
NS-series Programmable Terminals. The Switch
Box Function can be used to monitor the status
of each bit in a word or a combination of user-
selected bits organized like a ladder program
section. The Switch Box Function makes it
possible to perform basic troubleshooting on
the factory floor even without a computer.
Image Capture Function
Do not want to be aware of
ladder programs and PLC
memory areas.
Only want to display I/O
comments and I/O status.
When necessary, the displayed image can be captured and
saved in a Memory Card in BMP format. The saved image
can then be uploaded from remote personal computer via
Ethernet or Serial connection.
The number of images that can be saved depends on the
capacity of Memory Card. As an example, about 50 images
from a 640x480 display (about 600 Kbytes each) can be
saved in a 30-Mbyte Memory Card.
Solve with the Device Monitor
function
Monitoring PLC I/O Data for
the Purpose of Device Debugging
and Maintenance
Display PC Screens with the NS-CA002
NS-CA002 RGB/Video Input Unit
(Supported by the NS12-V /NS10-V /NS8-V .)
PT System
Image capture data read function
Ver. 6 or Higher
Display PLC memory
areas without using tools.
An analog RGB input terminal is provided in addition to two
video input interface terminals. A single video or analog
RGB display is possible on the NS-series PT. In that case,
video display is possible in user-defined positions and sizes.
Touch switches and parts, such as lamps, can be
overlapped on the video display. The display of parts will
not disappear.
Device Monitor Function
BMP data captured and saved in a Memory Card can be
read on the PT. BMP data displayed in thumbnails
can be selected and displayed on the captured data display
screen that will appear for the command button.
The Device Monitor Function is a standard feature
in the NS-series Programmable Terminals. Data in
the PLC’s I/O memory can be accessed directly
(read and written.) The Device Monitor provides
functions that can significantly reduce the time
needed to set up the system, such as displaying a
block of consecutive PLC data area addresses and
inputting/verifying parameters in CPU Bus Units
and Special I/O Units.
Want to display and change the
PLC memory areas without
showing the PLC program.
If an error occurs, the image when the error occurred can be displayed
on the NS screen. This is useful for on-site error analysis.
Solve with the Ladder Monitor
function
Monitoring Execution of
the PLC's Ladder Program
Ladder Monitor Function
(NS12-V /NS10-V /NS8-V
)
Display program
The Ladder Monitor Software provided with the
CX-Designer can be used to monitor states,
search for addresses and instructions, and
monitor multiple I/O points at the same time in
CS/CJ-series PLCs ladder programs via a serial,
Controller Link, or Ethernet connection. Copy
the Ladder Monitor software to a Memory Card
and install the Memory Card in the NS-series PT
to enable these monitoring and searching
operations. It is also possible to display I/O
comments created with the CX-Programmer
using an I/O Comment Extract Tool.
without using tools
Want to identify the fault location
by checking the actual PLC
program.
Want to change part of the
program, a timer/counter, without
connecting tools.
RGB
Console
Camera
From CX-Designer version 1.0, the Ladder Monitor software is
stored in the following folder on the CD-ROM. Copy it to a Memory
Card (sold separately) to use it.
Note: Two video signals cannot be simultaneously input to a
For Experts
single screen.
CX-One Disk 3: \Utility\CX-Designer\English\
LadderMonitorFunc.
CX-Designer CD-ROM: \Utility\English\LadderMonitorFunc.
NS-CA001 Video Input Unit
(Supported by the NS12-V /NS10-V /NS8-V .)
Four video input interfaces are provided, so four video or
CCD cameras can be connected. Up to four images can be
displayed simultaneously if the image size is 320x240
pixels.
Facilitate Equipment Maintenance
Integrating Special Unit Functions or Component Peripheral Tool Functions into PTs
Smart Active Parts
The following Smart Active Parts are provided and can be installed on the NS-Designer (version 6 or higher).
For CS/CJ AND CS1D CPU Unit
For Inverters (See note.)
Error Log Monitor, Online Battery Change Button, etc.
For Serial Communications Boards/Units
Communications Status Displays (Error Monitor), Ports Settings, etc.
For Ethernet Units/CLK Units
Rotation Speed/Monitoring Output Frequency, Other Parameter
Settings, etc.
For DeviceNet
DRT2 Maintenance/Status Information, IN/OUT Information, etc.
For Temperature Controllers (E5 R, E5ZN, E5 N and
Network Status Displays (Error Monitor and Network Node Status), etc.
For MC/MCH Unit
JOG Running, Search Zero Position, Program Running, Error Displays,
I/O Status Monitor, PV Monitor, etc.
CJ1W-TC)
Run Monitor, PID Settings SP Settings, Alarm Settings, Input
Correction Settings, etc.
Console
For NC/NCF Unit
For Sensors (E3X-DRT)
JOG Running, Direct Running, Memory Running (NC Only), Error
Displays I/O Status Monitor, PV Monitor, etc.
Threshold Settings, Monitoring Light Reception Levels, Etc.
For the SmartSlice GRT1 Series
Communications Unit Status, Warning/Alarm Flags, Network
Joining/Leaving Status
Wireless Terminals for WT30
Monitoring Slave Operating Status in a Wireless Environment
Camera
For Servo (R88D-WT, R7D-AP) (See note.)
PV Monitor, Parameter Settings, Error Displays, Driver Information
Displays, I/O Status Monitor, etc.
Note: Smart Active Parts require a Serial Communications Units/Boards
(version 1.2 or later).
14
15
Download from Www.Somanuals.com. All Manuals Search And Download.
High-reliability and Advanced Functions in
the Industry’s Slimmest PT
Super-thin 48.5-mm Body for a Slimmer Control Panel
Using a Personal Computer to Check PT Operation
This thin-profile model has few protrusions so it can be incorporated easily into a panel or machine.
The PT can help save space when space is at a premium.
Using a Personal Computer to Check the
Test Mode Window
Virtual PLC address
Operation of Created Functional Objects
NS12, NS10
Simulation via the “Test Function”
When a test is started, a test screen and virtual PLC will be
Memory Card interface
displayed on the computer.
Virtual
Test mode
PLC address
CX-Designer
1
Set values:
300
300
Present values: 500
500
Operating (clicking with the mouse) the functional objects
on the test screen will change the corresponding address in
the virtual PLC. Conversely, changing the content of a
virtual PLC address will change the corresponding
functional objects. It is also possible to confirm pop-up
screens. This function can be used to confirm the actual
operation of a screen during the editing.
Start of Test
Memory Card
Note: Colors shown in photographs and product
names may differ from actual colors and
names.
9999
9999
Set value:
Created screen
Present values:
Expansion interface
Battery
The test function enables debugging screens without NS
and PLC Hardware.
Transferring Screen Data to the PT On-site from a Memory Card
RS-232C serial port A
RS-232C serial port B
Memory Card: Upload/Download Function
It is possible to download the screen data and system
program to Memory Card and upload the same data from
the Memory Card. It is also possible to automatically
upload the data from the Memory Card to CX-Designer or
automatically download the data from Memory Card to PT
when the power of PT is turned ON.
CX-Designer
Screen data
Automatic transfer
NS-series PT
Screen data
when power of PT
is turned ON.
A bar code reader can be connected
Memory
Card
Power Supply (24 VDC)
USB HOST (for printer)
Ethernet (10Base-T or 100Base-TX)
USB SLAVE (For screen data transfer)
to the serial port.
Recommended bar code reader: V520-RH21-6
Memory Card
NS8
Memory Card interface
NS-series PT
Using General Software
Setting Functional Object Properties in Excel
Using Excel to Analyze Data, Such as the Alarm/Event
History, Operation Log, and Error Log, and to Create
Daily Reports
CSV File Input/Output
Expansion interface
The property settings for each functional object can be
exported in CSV format. The settings data can be imported
again after it has been edited with a program such as Excel.
Memory Card
Note: Colors shown in photographs and product
names may differ from actual colors and
names.
Memory Card: Data Logging Function
Logging data (trend data, up to 50,000 points with a
sampling cycle of 0.5 or 1 to 86,400 s/group) can be stored
in the Memory Card in CSV format.
Editing Text and Bitmap File with Your
Favorite Text Editor
Battery
Logging of
trend data
Editor Specifying Function
The user can select the editor when editing text or bitmap
files.
RS-232C serial port A
RS-232C serial port B
Creating System-related Documents
A bar code reader can be connected
to the serial port.
Power
Supply
(24 VDC)
Memory Card
Recommended bar code reader: V520-RH21-6
Outputting Project Information in RTF
Ethernet
(10Base-T or 100Base-TX)
Data such as screen information and object information can
be output in an RTF file. The RTF file can be read into Word
Processor to produce a system manual.
USB SLAVE (For screen data transfer)
Using Excel to Analyze Time-series Data and
to Create Daily Reports
Example of an RTF File Read into Word Processor
USB HOST (for printer)
Pasted Screen Data as
RTF Data
Object Properties as
RTF Data
Memory Card: History Storage Function
The following data can be saved to the Memory Card in
CSV format.
Alarm/Event History (Alarm/ Event history data)
Operation Log (Screen operation history data)
Error Log (Error log data recorded during macro program
execution)
Built-in Expansion Interface
The NS-series PTs have a built-in Expansion Interface for
future expandability.
USB Ports
A printer can be connected to the USB HOST port.
Refer to Printer Support on page 10 for recommended
printers.
16
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions
NS5
Memory Card interface
NS12/10 PT Units: mm
NS8 PT Units: mm
177
165 188
140 241
227 249
15.5
180
232
5
39 (min.)
42 (max.)
48.5
49
Memory Card
Note: Colors shown in photographs and product names
may differ from actual colors and names.
15.5
264
315
323
7.5
39 (min.)
42 (max.)
48.5
49
Expansion interface
220
301
Ethernet (10Base-T or 100Base-TX)
USB SLAVE (For screen data transfer)
RS-232C serial port A
Recommended
Panel Cutout Dimensions
Battery
SW
RESET
Recommended
Panel Cutout Dimensions
Power Supply
(24 VDC)
+0.5
165.5
24V
DC
–0
PORT
B
PORT
A
120.5
107.6
HOST
SLAVE
ETHERNET
RS-232C serial port B
SW
19.1
+0.5
–0
RESET
220.5
A bar code reader can be connected
to the serial port.
Recommended bar code reader: V520-RH21-6
+1
–0
228
121
134
24V
DC
PORT
B
PORT
A
26.6 9.6
HOST
SLAVE
ETHERNET
44.1 50.1
63.4
+1
–0
302
13.7
49.9
90.4
Optional Products
3.8
23
RS-422A Adapter
CJ1W-CIF11
Video Input Unit
RGB/Video Input Unit
Controller Link Interface Unit
NS-CLK21 (with Cover)
NS-CA001(with Cover)
NS-CA002 (with cover)
NS5 PT Units: mm
NS5 Hand-held PT Units: mm
39.83
16.5
195
223
70.5
ÇqÇtÇm
153.3
27.3
44.55
142
130.5
176
15.5
145
206.3
5
34 (min.)
38 (max.)
90
53.8
54.8
Protective Cover/Anti-reflection
Sheet for NS-series PT
NS -KBA0(N)
RS-232/RS-422A Conversion
Communications Cable
XW2Z-S002
USB Serial Conversion Cable
CS1W-CIF31
Unit
NT30/NT31C-KBA05(N)
NS-AL002
183.5
Recommended
Panel Cutout Dimensions
ÇrÇv
1
2
3
4
OFF
5
6
OFF
OFF
OFF
OFF
OFF
PORT
B
PORT
A
+0.5
–0
131
68.48
RESET
ETHERNET
21
51.7
+0.5
–0
184
19.5
77
Note: Colors shown in photographs and product names may differ from actual colors and names.
NS-CA001 Video Input Unit
NS-CA002 Video Input Unit
NS-CLK21
Units: mm
Units: mm
Controller Link Interface Unit
Units: mm
81.3
81.3
(102.7)
(102.7)
151.5
(183)
9.6
21.4
9.6
21.4
164
5
5
(169)
164
(169)
(1.9)
(1.9)
127.3
(22.3)
20.4
11
9.7
31.5
(22.3)
20.4
11
9.7
11.1
39.3
57.3
82.8
118.3
164
5
10.6
(169)
50.3
68.3
86.3
104.3
(1.9)
10.8
(33.9)
32
11
95.6
18
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance/Specifications
General Specifications
NS12/NS10/NS8/NS5-V2
Display Element Specifications
Characteristics
Display Specifications
Communications Specifications
Serial Communications
Item
Specification
Item
NS12-V2
NS10-V2
NS8-V2
NS5-V2/NSH5-V2
Item
Specifications
Item
Specification
Raster font
Displayable characters
Base size
TFT color LCD
STN color LCD
Monochrome LCD
Rated power supply voltage 24 VDC
Alphanumeric characters
or Japanese katakana
1 x 1, 1 x 2, 2 x 1,
2 x 2, 3 x 3, 4 x 4, 8 x 8
Conforms to EIA RS-232C.
D-Sub female 9-pin connector
5-V output (250 mA max.) through pin 6 (See note.)
Display device
High-definition TFT color LCD
Rough
8 x 8
Port A
Allowable voltage range
Power consumption
20.4 to 27.6 VDC (24 VDC ±15%)
Alphanumeric characters
or Japanese, Chinese
(Simplified, Traditional)
or Korean
800 dot horizontal x
600 dot vertical
320 dot horizontal x
240 dot vertical
25 W max. (15 W max. for the NS5)
Number of dots
Display color
640 dot horizontal x 480 dot vertical
256 colors
Font
name
Standard
8 x 16 1 x 1, 1 x 2, 2 x 1,
16 x 16 2 x 2, 3 x 3, 4 x 4, 8 x 8
Conforms to EIA RS-232C.
D-Sub female 9-pin connector
5-V output (250 mA max.) through pin 6 (See note.)
Ambient operating temperature 0 to 50°C (See notes 1 and 4.)
Display
text
Port B
Storage temperature
–20 to 60°C (See note 2.)
Width 246.0 mm x Width 215.2 mm x Width 170.9 mm x
Width 117.2 mm x
height 88.4 mm
(5.7 inches)
TFT: Left/right 70°,
Top 70°, bottom 50°
STN: Left/right 50°,
Top 45°, bottom 50°
Monochrome:
Display
panel
Effective
display area
Alphanumeric characters
or Japanese katakana
Japanese kanji
height 184.5 mm
(12.1 inches)
height 162.4 mm
(10.4 inches)
height 128.2 mm
(8.4 inches)
16 x 32 1 x 1, 1 x 2, 2 x 1,
32 x 32 2 x 2, 3 x 3, 4 x 4, 8 x 8
Fine
35% to 85% (0 to 40°C) with no condensation
35% to 60% (40 to 50°C) with no condensation
Note: The 5-V outputs of serial ports A and B cannot be used at the same time.
Ambient operating humidity
Operating environment
Noise immunity
No corrosive gases.
Vector font
(text objects only)
Can be specified in CX-Designer.
Font, style, and size can be specified.
Controller Link (Wired-type) Specifications
Left/right ±60°,
Left/right ±60°,
Left/right ±65°,
Conforms to IEC61000-4-4, 2 kV (power lines)
Field of vision
Service life
Top 45°, bottom 75° Top 35°, bottom 65° Top 50°, bottom 60°
Item
Specification
(See note 1.)
Color
256 colors
Conforms to JIS C0040.
Baud rate
2M/1M/500K
Shielded twisted-pair cable (special cable)
Left/right 45°,
Top 20°, bottom 40°
Vibration resistance
(during operation)
10 to 57 Hz, 0.075 mm amplitude, 57 to 150 Hz,
Font style (only when
vector font is specified)
2
Transmission path
Bold or italic
9.8 m/s 30 min each in X, Y, and Z directions
Text
attributes
TFT, STN: 75,000
hours min. (See
note 2.)
Monochrome:
50,000 hours min.
(See note 2.)
Shock resistance
(during operation)
Conforms to JIS C0041.
147 m/s 3 times each in direction of X, Y, and Z.
Vertical alignment
Horizontal alignment
Functional
Top, center, or bottom
2
Ethernet Specifications
50,000 hours min. (See note 2.)
Left-justified, centered, or right-justified
NS12: 2.5 kg max.; NS10: 2.3 kg max.;
NS8: 2.0 kg max.; NS5: 1.0 kg max.
Weight
Item
Specification
Conforms to IEEE 802.3/Ethernet (10Base-T/100Base-T).
Backlight
(See note
5.)
Up to 10 types can be registered.
The flicker speed and flicker range can be set.
Objects
objects
Front operating panel: IP65F and NEMA4 compliant
(See note 3.)
Conformance standards
Enclosure rating
Brightness
adjustment
Backlight error
detection
that can
Flicker
There are 3 levels that can be set with the touch panel. (See note 3.)
Fixed
flicker
Select from 3 types.
objects
The flicker speed and flicker range are fixed.
5 years (at 25°C) Replace battery within 5 days
after the battery runs low (indicator lights orange).
Error is detected automatically, and the RUN
indicator flashes green as notification. (See note 4.)
Battery life
Video Input Specifications
Numeral units and scale settings 1,000 max.
Item
NS-CA001
NS-CA002
Applicable standards
cULus and EC directives
Note 1: The bottom angle is 55° for V1 models.
Alarm/event settings
Display colors
5,000 max.
2: This is the estimated time before brightness is reduced by half at room temperature
and humidity. It is not a guaranteed value. The service life will be drastically shortened
if PT is used at low temperatures. For example, using the PT at temperatures of 0°C
will reduce the service life to approximately 10,000 hours (reference value).
3: The brightness cannot be adjusted much.
4: This function does not indicate that the service life has been reached. It detects when
the backlight is not lit due to a disconnection or other errors. Backlight error detection
indicates that all backlights (2) are OFF.
Resolution
Input signal
320 x 240, 640 x 480, or 800 x 600 dots
NTSC composite video or PAL
User-defined size
Note 1: The operating temperature is subject to the following restrictions according to the mounting
angle.
256 colors max. (32,768 colors for BMP)
NTSC composite
video or PAL
Mounting angle of 0 to 30° to the horizontal: Operating temperature range of 0 to 45°C
When a Video Input Unit or a Controller Link Interface Unit is mounted, the ambient operating
temperature is 0 to 35°C.
CX-One Operating Environment
2 cameras + RGB
Cameras
Number of cameras: 4 max.
Mounting angle of 30 to 90° to the horizontal: See note 4.
Windows 98 SE, Me, NT 4.0 (Service Pack 6a), 2000 (Service
Compatible OS
Note 2: Operate the PT within the temperature and humidity ranges shown in the following diagram.
Pack 3 or higher), or XP (See note 1.)
5: Contact your nearest OMRON representative to replace the backlight.
Humidity (%)
95% 80%
USB Specifications
Pentium II 333 MHz or faster processor (Pentium III 1 GHz or
faster recommended.)
Recommended CPU
Storage
Operating Specifications
Item
Specifications
60%
60
Operation
Recommended memory 256 Mbytes min. (See note 2.)
90°
Item
Specification
Resistive membrane
USB rating
Connector
USB1.1
Type A (Host), Type B (Slave)
50
Approx. 1.8 GB or more available space is required to install
Hard disk free space
40%
Method
the complete CX-One package.
Temperature (°C)
30
40
35%
20%
NS12-V2
1,900 (50 horizontal x 38 vertical) 16 x 16 dots for each switch.
1,200 (40 horizontal x 30 vertical) 16 x 16 dots for each switch.
768 (32 horizontal x 24 vertical) 20 x 20 dots for each switch.
300 (20 horizontal x 15 vertical) 16 x 16 dots for each switch.
CD-ROM drive
Display
Required for installation
30°
20
10
Number
of
switches
Touch
panel
(Matrix
type)
0
NS10-V2
SVGA (800 x 600) or better high-resolution display with 256 colors min.
10%
Horizontal
(0°)
NS8-V2
Note 1: CX-One OS precaution
—20
0
10 20 30 40 50 60 70 80
Temperature (°C)
The CX-One will not run on Microsoft Windows 95 or any other OS not listed above.
If such an OS is being used on the client computer, the OS must be upgraded before installing the
CX-One. System requirements and hard disk space may vary with the system environment.
2: The amount of memory required varies the Support Software applications used in CX-One.
Refer to use documentation for Individual Support Software for details.
NS5-V2/NSH5
Note 3: May not be applicable in locations with long-term exposure to oil.
Note 4: •NS12/NS10/NS5
Compatible OMRON PLCs
Input
Pressure-sensitive
Mounting angle of 30° to 90° or less to the horizontal: Operating temperature range of 0 to 50°C
•NS8
Mounting angle of 30° to less than 90° to the horizontal: Operating temperature range of 0 to 45°C
Mounting angle of 90° to the horizontal: Operating temperature range of 0 to 50°C
Service life
1,000,000 touch operations.
CPU Units (1:1 NT Link Connection)
Model number
CQM1-CPU41-V1/CPU42-V1/CPU43-V1/CPU44-V1
CQM1H-CPU21/CPU51/CPU61
Specifications
PLC model name
C-series CQM1
Data Capacity Specification
Series Display device model
NSH5-SQROOB-V2
With RS-232C connector (9-pin type)
V 1
V 2
C-series CQM1H
C-series CPM1
Item
Specification
MQ (monochrome)
TQ (TFT)
20 MB
20 MB
20 MB
20 MB
60 MB
60 MB
60 MB
CPM1-10/20CDR- + CPM1-CIF01
Rated power supply voltage
Allowable voltage range
24 VDC
NS5
Connect to peripheral port.
CPM1A-10/20/30/40CD
CPM2A-30/40/60CD
CPM2C-10/20
-
+ CPM1-CIF01
+ CPM1-CIF01
C-series CPM1A
C-series CPM2A
C-series CPM2C
C-series C200HS
C-series C200HE (-Z)
C-series C200HG (-Z)
C-series C200HX (-Z)
20.4 to 26.4 VDC (24 VDC –15%/+10%)
10 W max.
SQ (STN)
SQ (STN)
TV (TFT)
6 MB
-
Connect to RS-232C or peripheral port.
Power consumption
NSH5
NS8
-
(See note 1.)
Ambient operating temperature
Storage temperature
0 to 40°C
20 MB
20 MB
20 MB
C200HS-CPU21/CPU23/CPU31/CPU33
–20 to 60°C
NS10
NS12
TV (TFT)
C200HE-CPU32(-Z) (See note 2.) /CPU42(-Z)
With RS-232C connector (9-pin type)
Ambient operating humidity
Operating environment
35% to 85% with no condensation
No corrosive gases.
TS (TFT)
C200HG-CPU33(-Z) (See note 2.) /CPU43(-Z) /CPU53(-Z) (See note 2.) /CPU63(-Z)
C200HX-CPU34(-Z) (See note 2.) /CPU44(-Z) /CPU54(-Z) (See note 2.) /CPU64(-Z) /CPU65-Z/CPU85-Z
External Interface Specifications
Common mode: 1,000 Vp-p (between power
supply terminals and panel)
Normal mode: 300 Vp-p
CVM1/CV-series
CVM1 or CV500/
CV1000/CV2000
Item
Specifications
CV500/1000/2000-CPU01-V1
CVM1-CPU01-V2/CPU11-V2/CPU21-V2
Noise immunity
With RS-232C connector (switching/9-pin type)
Memory card
interface
One ATA-Compact Flash interface slot.
Used to transfer and store screen data and to store history data.
Pulse width: 100 ns to 1 µs, Rise time: 1-ns pulse
Note 1: Use an Adapter Cable (CPM2C-CN111 or CS1W-CN114/118), CPM1-CIF01 RS-232C Adapter, or CPM1-CIF11 RS-422A Adapter to connect.
Vibration resistance
(during operation)
Conforms to JIS C0911.
2: A C200HW-COM02(-V1), C200HW-COM04(-V1), C200HW-COM05(-V1), or C200HW-COM06(-V1) Communications Board is required.
Expansion
interface
For Expansion Interface Units
CPU Units (1:N NT Link Connection)
Shock resistance
(during operation)
Conforms to JIS C0912.
Model number
CS1G-CPU42H/CPU43H/CPU44H/CPU45H
CS1H-CPU63H/CPU64H/CPU65H/CPU66H/CPU67H
CS1D-CPU65H/CPU67H
Specifications
PLC model name
CS-series CS1G
CS-series CS1H
CS-series CS1D
CJ-series CJ1G
CJ-series CJ1G
Weight
1 kg max.
Enclosure rating
Ground
IP65 compliant
Ground to 100 Ω or less.
UL508 and EC directives
Applicable standards
CJ1G-CPU42H/CPU43H/CPU44H/CPU45H (See note 1.)
CJ1G-CPU42P/CPU43P/CPU44P/CPU45P
CJ1H-CPU65H/CPU66H/CPU67H (See note 1.)
CJ-series CJ1H
With RS-232C connector (9-pin type)
CJ1M-CPU11/CPU12/CPU13/CPU21/CPU22/CPU23 (See note 1.)
CJ-series CJ1M
C-series CQM1H
C-series C200HE(-Z)
C-series C200HG(-Z)
C-series C200HX(-Z)
CQM1H-CPU61/51 with a CQM1H-SCB41 Serial Communications Board
C200HE-CPU32(-Z) (See note 2.) /CPU42(-Z)
C200HG-CPU33(-Z) (See note 2.) /CPU43(-Z) /CPU53(-Z) (See note 2.) /CPU63(-Z)
C200HX-CPU34(-Z) (See note 2.) /CPU44(-Z) /CPU54(-Z) (See note 2.) /CPU64(-Z) /CPU65-Z/CPU85-Z
Note 1: The CJ1W-SCU21/SCU41 Serial Communications Unit can also be connected.
2: A C200HW-COM02/COM04/COM05/COM06(-V1) Communications Board is required.
21
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Connections through CPU Unit/Host Link
Options
Superior environmental resistance
meets IP65F standards.
Flush surface construction is used for superior
environmental resistance and the enclosure rating for
the front of the PT is IP65F compliant.
IP International Protection
Model number
Specifications
RS-232C or RS-422A adapter connected to peripheral port
RS-232C connector (9-pin)
PLC model name
C Series: CPM1
Model name
Specifications
Model number
NS-CA001
CPM1-10CDR/20CDR- /CPM1A-10CD/20CD/30CD/40CD
CPM2A-30CD/40CD/60CD
-
Inputs: 4 channels
Signal type: NTSC/PAL
-
C Series: CPM2A
C Series: CPM2C
Video Input
Unit
Input channels: 2 video
channels and 1 RGB
channel (See note.)
Communications connectors include both a peripheral port and
RS-232C port (branching possible through CPM2C-CN111
Conversion Cable).
Used as separate peripheral and RS-232C ports through CS1W-
CN114/118 Conversion Cable.
NS-CA002
CPM2C-10/20
-
Signal mode: NTSC/PAL
6
Dust and dirt will not enter interior.
(Enclosure protects against foreign objects.)
There are no adverse effects from a water stream
from any direction.
(Enclosure protects against water intrusion.)
There are no harmful effects from oil droplets or
spray from any direction. (Enclosure protects
against oil intrusion.)
F150-VKP (2m)
F150-VKP (5m)
Special Cable for the Console
RS-232C connector (9-pin)
CQM1-CPU21/CPU41-V1/CPU42-V1/CPU43-V1/CPU44-V1
CQM1H-CPU11/CPU21/CPU51/CPU61
C Series: CQM1
RS-232C connector (9-pin) (Only peripheral port for CQM1H-CPU11)
C Series: CQM1H
C Series: C200HS
C Series: C200HE (-Z)
C Series: C200HG (-Z)
C Series: C200HX (-Z)
CS Series: CS1G
5
Controller Link
Interface Unit
For Controller Link
Communications
NS-CLK21
C200HS-CPU21/CPU23/CPU31/CPU33
C200HE-CPU32(-Z)(See note.)/CPU42(-Z)
Transmission distance:
500 m total length
Note: Use this model when
connecting PT models without a V
suffix.
Note: PT models with a suffix of V
can also be connected.
RS-232C connector (9-pin, selectable)
F
C200HG-CPU33(-Z)(See note.)/CPU43(-Z)/CPU53(-Z)(See note.)/CPU63(-Z)
C200HX-CPU34(-Z)(See note.)/CPU44(-Z)/CPU54(-Z)(See note.)/CPU64(-Z)/CPU65-Z/CPU85-Z
CS1G-CPU42(-V1)/CPU43(-V1)/CPU44(-V1)/CPU45(-V1)
NS-AL002
RS-232C connector (9-pin)
RS-422A
Adapter
Note: May not be applicable in environments with long-term exposure to water or oil.
CS Series: CS1H
CS1H-CPU63(-V1)/CPU64(-V1)/CPU65(-V1)/CPU66(-V1)/CPU67(-V1)
Transmission distance:
50 m total length
Note: Only PT models with a suffix
of V are connectable. Use the
NS-002 to connect models without
a V suffix.
CVM1/CV Series:
CV500/1000/2000 or
CVM1
CV500-CPU01-V1/CV1000-CPU01-V1/CV2000-CPU01-V1/
CVM1-CPU01-V2/CPU11-V2/CPU21-V2
RS-232C connector (9-pin, selectable)
Meets International Standards and
Exports are Not Restricted
The PTs conform to UL standards (cULus) and EC
Directives.
In addition, there are no export restrictions on the PTs.
cULus certification is scheduled for the near future for
the NSH5 5-inch Hand-held PT.
CJ1W-CIF11
Note: The C200HW-COM02, C200HW-COM04, C200HW-COM05, or C200HW-COM06(-V1) Communications Board is required.
NS12/10
NS12-KBA04
NS7-KBA04
Anti-reflection Sheets
(5 surface sheets)
NS8
NS5
NT30-KBA04
NS12-KBA05
NS7-KBA05
Standard Models
NS12/10
NS8
Protective Covers
(5 pack)
(anti-reflection coating)
Sheet/Cover
Model
Specifications
Model number Standards
Model name
Specifications
Model number
CXONE-AL01C-E
Ethernet Case color
name
NS5
NT31C-KBA05
NS12-KBA05N
NS7-KBA05N
NT31C-KBA05N
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CU, CE
CE,
The CX-One is an integrated
tool package that provides
programming and monitoring
software for OMRON PLCs and
components. The CX-One runs
on any of the following
operating systems:
Windows 98 SE, Me, NT 4.0
(Service Pack 6a), 2000 (Service
Pack 3 or higher), or XP.
CX-Designer version 1. is
included in the CX-One.
Refer to the CX-One catalog
(R134) for details.
Ivory
NS12-TS00-V2
NS12-TS00B-V2
NS12-TS01-V2
NS12-TS01B-V2
NS10-TV00-V2
NS10-TV00B-V2
NS10-TV01-V2
NS10-TV01B-V2
NS8-TV00-V2
No
1 license
NS12/10
NS8
Protective Covers
(5 covers included)
(Transparent)
Black
12-inch TFT
800 x 600 dots
NS12
Ivory
Yes
3 licenses
CXONE-AL03C-E
NS5
Black
(NT625C/631/631C Series to NS12/10 Series)
(NT625C/631/631C Series to NS12/NS10 Series) (Black)
(NT610C Series to NS12/10 Series)
(NT620S/620C/600S Series to NS8 Series)
(NT600M/600G/610G/612G Series to NS8 Series)
30 MB
CX-One
NS12-ATT01
Ivory
FA Integrated
Tool Package
Ver. 1.1
No
10 licenses CXONE-AL10C-E
NS12-ATT01B
NS12-ATT02
Black
10-inch TFT
640 x 480 dots
NS10
NS8
Ivory
Yes
NS8-ATT01
NS8-ATT02
HMC-EF372
HMC-EF672
30 licenses CXONE-AL30C-E
50 licenses CXONE-AL50C-E
Black
Ivory
No
(See note 2.)
Black
NS8-TV00B-V2
NS8-TV01-V2
Memory Card
8-inch TFT
640 x 480 dots
64 MB
Ivory
The CX-Designer can also be ordered individually using the following model number.
Yes
Memory Card Adapter
Battery
HMC-AP001
CJ1W-BAT01
Black
NS8-TV01B-V2
NS5-SQ00-V2
NS5-SQ00B-V2
NS5-SQ01-V2
NS5-SQ01B-V2
NS5-TQ00-V2
NS5-TQ00B-V2
NS5-TQ01-V2
NS5-TQ01B-V2
NS5-MQ00-V2
NS5-MQ00B-V2
NS5-MQ01-V2
NS5-MQ01B-V2
OS: Window 98 SE, Me, NT 4.0
(Service Pack 6a),
2000 (Service Pack 3 or
higher), or XP.
Ivory
No
CX-Designer
Ver. 1.
Bar Code Reader
(Refer to the Catalog for details.)
1 license
NS-CXDC1-V1
XW2Z-S002
V520-RH21-6
Black
5-inch STN
320 x 240 dots
The Ladder Monitor Software
is included.
Ivory
Note: One screen cannot display two video inputs simultaneously.
Yes
Black
Screen transfer cable for DOS/V
Ivory
USB Host Cable, cable length: 5 m
USB Host Cable, cable length: 2 m
NS-US52 (5 m)
NS-US22 (2 m)
Related Products
No
Black
5-inch TFT
320 x 240 dots
Cable
(See note 1.)
NS5
Ivory
NS Series
USB-RS-232C Conversion Cable,
cable length: 0.5 m
Yes
WS02-NSFC1-EV2 Face Plate
Auto-Builder for NS
Significantly reduces the engineering time required by
combining LCB/LCU and the NS Series.
CS1W-CIF31
Black
Created screens are
easily transferred to the
NS by means of a
Memory Card or over
the network.
Ivory
RS-422A cable (loose wires)
Cable length: 10 m
No
NSH5-422CW-10M
NSH5-232CW-3M
5-inch
monochrome
320 x 240 dots
Black
RS-232C cable (loose wires)
Cable length: 3 m
Ivory
NSH5 Cables
Yes
Black
Automatic generation of control screens and tuning screens. Automatic
generation of NS screen data by the software from tag information created with
CX-Process Tool.
NS communications address allocation, ladder programs, etc., are completely
unnecessary.
Data that has been generated can be freely edited and processed by
CX-Designer (NS screen creation software).
RS-232C cable (loose wires)
Cable length: 10 m
NSH5-232CW-10M
5-inch STN
320 x 240 dots
NS5
Hand-held
CU
(approval
pending)
No
Black
NSH5-SQR001B-V2
Length: 2 m
Length: 5 m
XW2Z-200T
XW2Z-500T
NSH5-ATT02
SYSMAC CS1 +LCB/LCU
PT-to-PLC
Connecting Cable
PT connection: 9 pins
PLC connection: 9 pins
NSH5 Wall-mounting Bracket
CX-Designer
(NS screen creation software)
CSV tag file for
LCB/LCU
NS project file
Note 1: Use an OMRON USB Host Cable to connect an NS-series PT to a printer.
2: Site licenses are also available for users that need to use the CX-One on many computers.
Ask your OMRON representative for details.
Editing created data
Creation of other required screens
NS Faceplate Auto-Builder upgraded to version 2.0.
Maximum number of automatically generated loops
increased from 32 to 100.
Automatic generation from the CX-Process projects
that use multiple nodes.
Automatic generation of detailed setting screens for
Line Segment programs.
CX-Process Tool
(LCB/LCU programming software)
Face Plate
Auto-Builder for NS
LCB/LCU program creation
(function block method)
CSV tag file output
Specifications
Product name
Specifications
Model number
Face Plate Auto-Builder for NS
CSV tag files for LCB/LCU used in Face Plate Auto-Builder for NS
WS02-NSFC1-EV2
22
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Cat. No. V078-E1-09
2007.3
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Download from Www.Somanuals.com. All Manuals Search And Download.
|