DS30/Station Port Adapter
Installation Guide
• • • • • • • • • • • • • • • • • • •
Download from Www.Somanuals.com. All Manuals Search And Download.
1
DS30/STATION PORT ADAPTER
REGULATORY APPROVAL
Table 1. Regulatory Approvals
TYPE COUNTRY
SPECIFICATION
PROCEDURE
Radiated Canada
Emissions US
UK
ICES-003/CISPR22 Class B
FCC Part 15/CISPR22 Class B ANSI C63.4
ANSI C63.4
EN55022
ICES-003/CISPR22 Class B
ANSI C63.4
ANSI C63.4
Conducted Canada
Emissions United States FCC Part 15/CISPR22 Class B ANSI C63.4
UK
EN 55022
ANSI C63.4
EN50082-1
Safety
Canada
US
UK
CSA C22.2 No. 950-95 (CUL)
UL 1950 edition 3
EN 60950
International IEC 950 edition 2
NOTE
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. The limits are designed
to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses and can radiate radio frequency energy, and if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the
interference at his own expense.
WARNING
Use only UL CSA/cUL approved Class 2 Wall Mount
Power Supply with a rated output of 12VAC.
DS30/Station Port Adapter
Installation Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2
PRODUCT DESCRIPTION
Table 2. Product Description
CONNECTOR RJ-45 Jacks
INTERFACES
DS-30 Fiber
Two RJ-45 jacks each accepting up to
four TCM Loops
One female DS-30
Connector
Power
Connector
fiber optic connector pair
One barrel jack for internal
power supply to wall mounted 12 VAC
power source
SIZE
Approx. 9.75” (248 mm) x 5.06” (129 mm) x 1.22”
(36mm)
WEIGHT
POWER
Estimated 20 ounces (567 grams) includes bezel and
PCB but not wall-mounted power supply
Country
Output/Input Rating
North America
United Kingdom
Australia
12VAC @ 600mA/110VAC
12VAC @ 600mA/240VAC
12VAC @ 600mA/240VAC
RELIABILITY Mean time before failure (MTBF) target is greater than
20 years using Mil-Std-217F method TBD reliability
calculations.
FUNCTIONAL Multiplexes up to eight Nortel Norstar TCM Loops
DESCRIPTION (up to 16 voice paths) into one DS-30 fiber optic
line. Each TCM Loop may include up to two active
voice/data paths as well as a control signaling path.
TCM
Loop
RJ-45 Connectors
TCM
TCM
Loops Loops
1-4 5-8
Status
LEDs (8) Connector
AC Power DS30 Fiber
Connector
1 4 7
2 5 8
3 6
FIBER
DS - 30
KSU 1 - 4 KSU 5 - 8
LINE POWER FIBER OPTIC
Fiber Line Status LED
Figure 1. DS-30/Station Port Adapter
Installation Guide DS30/Station Port Adapter
Download from Www.Somanuals.com. All Manuals Search And Download.
3
INSTALLATION
1. Connect the TCM Loops from the KSU to a male RJ-45 connector
using the wiring scheme in Figure 2 below. Connect up to 8 TCM
Loops with TCM Loops 1 to 4 in RJ-45 connector 1 and TCM Loops 5
to 8 in RJ-45 connector 2.
2. Insert KSU RJ-45 male connector(s) into the appropriate female RJ-45
connector in the adapter.
3. Insert DS-30 fiber connector of fiber line from Applications Module
into DS-30 Fiber Connector of adapter.
4. Plug power cord into AC Power Connector.
5. Plug the adapter power into anAC wall outlet. WARNING: Use only UL
CSA/cUL approved Class 2 Wall Mount Power Supply with a rated
output of 12VAC.
To Adapter
RJ-45
To Adapter
RJ-45
Connector
Connector
Female RJ-45
JP1
Female RJ-45
JP1
TCM Loops 1-4
TCM Loops 5-8
8
7
6
5
4
3
2
1
Pins 1-8
8
7
6
5
4
3
2
1
Pins 1-8
Loops 1-4
4- 3- 2- 1- 1+ 2+ 3+ 4+ Loops 5-8
8- 7- 6- 5- 5+ 6+ 7+ 8+
To Norstar KSU
To Norstar KSU
Figure 2. TCM Loop RJ-45 Pinout Connections
DS-30/Station Port Adapter
Fiber
Spool
1
2
3
4
5
6
7
8
FIBER
DS
-
30
KSU
1
-
4
KSU
5
-
8
LINE POWER FIBER OPTIC
Norstar KSU
Applications Module
Figure 3. Installation Diagram
DS30/Station Port Adapter
Installation Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
4
TROUBLESHOOTING
Table 3. Troubleshooting Guide
SITUATION
Fiber Line LED light is
flashing
INDICATION LINK
ACTION
Power on
Invalid Check fiber
connection between
units
Fiber Line LED light is off
Fiber Line LED light is on
No Power
Power on
Invalid Check power source
Valid
None
None
TCM Loop LED port light
is on
TCM Loop LED port light
is off
Active port
connection
Inactive port
connection
Valid
Invalid Check corresponding
port connection
NOTE: Timing master uses highest numbered TCM Loop connected
port to synchronize DS-30 link.
The DS30/Station Port Adapter is compatible with ACCESS 2.6
ver. 6.52 and higher within application products running on the
NAM II platform. Systems with previous versions of ACCESS
should obtain an appropriate upgrade.
TCM Loop 1
1 4 7
Fiber Line
2 5 8
FIBER
LINE
3 6
Figure 4. Close-upView of LEDs
Installation Guide
DS30/Station Port Adapter
Download from Www.Somanuals.com. All Manuals Search And Download.
|