Using the BayStack
Ethernet Fiber Media
Adapters
Bay Networks, Inc. Corporate Headquarters
4401 Great America Parkway
Santa Clara, CA 95054
8 Federal Street
Billerica, MA 01821
March 1996
*893-862-B*
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
This guide describes the Bay Networks 10BASE-FL (fiber link)
and single-mode fiber media adapters for the BayStack
10BASE-T Hubs, and provides instructions for installing,
connecting, and configuring the adapters in the hub.
Each BayStack fiber media adapter provides one nonredundant
single- or multimode fiber port for flexible backbone
connectivity to your BayStack 10BASE-T Hub. Both adapters
employ 10BASE-FL signaling technology.
The BayStack 10BASE-T Hub provides two Media Adapter
LEDs to indicate the status of the hub media adapter ports A and
B. For more information about interpreting media adapter LEDs,
refer to Chapter 1, “Quick Reference Information,” in Using the
BayStack 10BASE-T Hubs.
This guide contains the following sections:
•
•
•
•
BayStack 10BASE-FL Media Adapter
BayStack Single Mode Fiber Media Adapter
Fiber Optic Cable Length Limitations
Installing a Media Adapter in a BayStack Hub
For more information about how the media adapter operates in
the hub, refer to Using the BayStack 10BASE-T Hubs (Bay
Networks Part number 893-839-B).
893-862-B
1
Download from Www.Somanuals.com. All Manuals Search And Download.
BayStack 10BASE-FL Media Adapter
The BayStack 10BASE-FL Media Adapter is a modular
10BASE-FL fiber link port. It is designed to be installed in either
media adapter slot of a BayStack 10BASE-T Hub.
The port is compatible with the IEEE 802.3 10BASE-FL
specification for Ethernet running over 62.5/125 µm or 50/125
µm multimode fiber optic cable.
TX
RX
10BASE-FL
5956
Connection is made to the port using two straight-tip (ST)
connectors (Tx and Rx).
For more information about multimode fiber optic cable
connection and limitations, see “Fiber Optic Cable Length
Limitations” later in this guide.
2
893-862-B
Download from Www.Somanuals.com. All Manuals Search And Download.
BayStack Single Mode Fiber Media Adapter
The BayStack Single Mode Fiber Media Adapter is a modular
port supporting 10BASE-F signaling. It is designed to be
installed in the media adapter slot of any BayStack 10BASE-T
Hub.
The port conforms to Bay Networks proprietary standards for
Ethernet running over 9/125 µm single-mode fiber optic cable.
No IEEE or other international standards exist for this
configuration at this time.
TX
RX
Single Mode Fiber
6770
Connection is made to the port using two straight-tip (ST)
connectors (Tx and Rx).
For more information about single-mode fiber optic cable
connection and limitations, see “Fiber Optic Cable Length
Limitations” next in this guide.
893-862-B
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Fiber Optic Cable Length Limitations
The 10BASE-F standard permits you to use fiber optic cables up
to 2000 meters long. However, the fiber connection must meet:
•
•
Optical power budget
Ethernet repeater rules
For more information about simple rules for Ethernet network
compliance, refer to Using the BayStack 10BASE-T Hubs.
BayStack 10BASE-FL Media Adapter
The optical power budget for the 10BASE-FL media adapter is
shown in Table 1. Power loss in the link cannot exceed the value
for the type of fiber optic cable you are using.
Table 1. 10BASE-FL Optical power budget
Parameter
62.5/125 µm
–20.0 dBm
–32.5 dBm
12.5 dB
50/125 µm
–25.7 dBm
–32.5 dBm
6.8 dB
Transmitted power (average)
Receiver sensitivity (average)
Optical power budget
Only in-line fiber-to-fiber connections (a connection between
two fibers terminated with fiber connectors, using a fiber-to-fiber
connector) count against the optical power budget. The loss in a
fiber connection at the ends of the link is included in the optical
power budget and does not count as an in-line connection.
4
893-862-B
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 2 lists the most common cable and connector combinations
for the 10BASE-FL media adapter, assuming the maximum
permitted attenuation with ST connectors. The table lists the
maximum (total) distance allowed in the fiber connection.
However, your fiber connection may have to be shorter to meet
the optical power budget and Ethernet repeater rules.
Table 2. 10BASE-FL cable and connector combinations
Number of in-line
fiber-to-fiber
62.5/125-µm
cable
50/125-µm
cable
connections
0
1
2000 m (6560 ft)
2000 m (6560 ft)
2000 m (6560 ft)
2000 m (6560 ft)
2000 m (6560 ft)
2000 m (6560 ft)
1750 m (5740 ft)
1500 m (4920 ft)
1250 m (4100 ft)
1000 m (3280 ft)
750 m (2460 ft)
500 m (1640 ft)
250 m (820 ft)
0
2000 m (6560 ft)
2000 m (6560 ft)
2000 m (6560 ft)
1710 m (5620 ft)
1430 m (4690 ft)
1140 m (3750 ft)
860 m (2810 ft)
570 m (1870 ft)
290 m (940 ft)
0
2
3
4
5
6
7
8
9
10
11
12
13
893-862-B
5
Download from Www.Somanuals.com. All Manuals Search And Download.
BayStack Single Mode Fiber Media Adapter
The optical power budget for the single-mode fiber media
adapter is shown in Table 1. Power loss in the link cannot exceed
the value for the type of fiber optic cable you are using.
Table 3. Single-mode fiber optical power budget
Parameter
9/125 µm
–29.0 dBm
–35.5 dBm
6.5 dB
Transmitted power (average)
Receiver sensitivity (average)
Optical power budget
Only in-line fiber-to-fiber connections (a connection between
two fibers terminated with fiber connectors, using a fiber-to-fiber
connector) count against the optical power budget. The loss in a
fiber connection at the ends of the link is included in the optical
power budget and does not count as an in-line connection.
NOTE: Your fiber connection must meet the optical
power budget and the Ethernet repeater rules for your
network.
6
893-862-B
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing a Media Adapter in a BayStack Hub
A BayStack 10BASE-FL media adapter is installed in a slot on
the front of the BayStack 10BASE-T Hub.
To install a media adapter, follow these steps:
1. Unplug the BayStack 10BASE-T Hub power cord from
the AC power source.
2. Remove the filler panel from the media adapter slot on
the front panel of the hub.
3. Install the media adapter into the media adapter slot.
a. Align the media adapter with the card guides and gently
slide in the media adapter until you feel it align with the
connector on the hub motherboard.
b. Firmly push the media adapter into the connector.
CAUTION: Do not force or overtighten the
captive retaining screw on the media adapter.
c. Tighten the captive retaining screw on the media adapter
by turning the screw clockwise.
4. Reconnect the power cord.
The hub powers up and performs a self-test.
5. Make appropriate cable connections.
For cabling information, see the section earlier in this guide
that refers to the media adapter you are installing.
893-862-B
7
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Verify the installation for the media adapter.
Observe for the installed media adapter that the respective
Media Adapter LEDs on the front panel of the hub light
according to Table 4.
Table 4. Media adapter status LEDs
Hub media
Media adapter status
adapter LEDs
Green
Amber
Off
Link status is good, port not partitioned.
Link status is good, port is partitioned.
Link status is bad or connection is not
present.
For more information about interpreting media adapter
LEDs, refer to Chapter 1, “Quick Reference Information,” in
Using the BayStack 10BASE-T Hubs.
8
893-862-B
Download from Www.Somanuals.com. All Manuals Search And Download.
Bay Networks, Inc. One-year Limited Hardware Warranty
Bay Networks warrants this hardware product will be free from defects in material
and workmanship for a period of one (1) year under normal operating conditions
from the date of original purchase.
Should you discover a defect in material or workmanship within this warranty
period, Bay Networks will repair or replace the defective product when it is
returned to Bay Networks, shipping prepaid. Replacement Products may be
refurbished or contain refurbished materials. If you purchased this product through
a Bay Networks reseller, please contact that reseller for return instructions. Prior to
returning any Product, you or the reseller must obtain a Return Materials
Authorization (RMA) number from Bay Networks. If Bay Networks, by its sole
determination, is unable to repair or replace the defective product, it will refund the
purchase price of the product. For products repaired or replaced by Bay Networks
under this warranty, the warranty will continue to apply for the unexpired period of
the original one (1) year warranty or for ninety (90) days following delivery of the
repaired or replacement product to you, whichever is longer.
This warranty does not apply if, in the judgment of Bay Networks, the Product fails
due to damage from shipment, handling, storage, accident, abuse or misuse, or if it
has been used or maintained in a manner not conforming to product manual
instructions, has been modified in any way, or has had any serial number removed
or defaced. Repair by anyone other than Bay Networks or an approved agent will
void this warranty. The maximum liability of Bay Networks under this warranty is
limited to the purchase price of the product covered by the warranty.
EXCEPT AS SPECIFICALLY PROVIDED IN THIS AGREEMENT OR AS
REQUIRED BY LAW, THE WARRANTIES AND REMEDIES STATED ABOVE
ARE EXCLUSIVE AND IN LIEU OF ALL OTHERS, ORAL OR WRITTEN,
EXPRESS OR IMPLIED. ANYANDALL OTHER WARRANTIES, INCLUDING
IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE AND NONINFRINGEMENT OF THIRD PARTY
RIGHTS ARE EXPRESSLY EXCLUDED. BAY NETWORKS SHALL NOT
UNDER ANY CIRCUMSTANCES BE LIABLE TO ANY PERSON FOR ANY
SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES,
INCLUDING, WITHOUT LIMITATION, DAMAGES RESULTING FROM USE
OR MALFUNCTION OF THE PRODUCTS, LOSS OF DATA, LOSS OF
PROFITS OR REVENUES OR COSTS OF REPLACEMENT GOODS, EVEN IF
INFORMED IN ADVANCE OF THE POSSIBILITY OF SUCH DAMAGES.
893-862-B
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Electromagnetic Emissions
Meets requirements of:
FCC Part 15, Class A Digital Devices
VCCI Class 1 ITE
EN 55 022 (CISPR 22, Class B)
General License Vfg 243 (Class B)
Compliance with the VCCI regulation is dependent upon the use of shielded AC
power cables. The user is responsible for procuring the appropriate cables.
Compliance with Class B regulations is dependent upon the use of shielded cables.
The user is responsible for procuring the appropriate cables.
For the complete electromagnetic emissions statements and declaration of
conformance, see Using the BayStack 10BASE-T Hubs (Bay Networks part number
893-839-A).
Bay Networks Customer Support
For information about a wide range of customer support services, call
1-800-2LANWAN.
10
893-862-B
Download from Www.Somanuals.com. All Manuals Search And Download.
|