IVB 3-H/5-H/7-H
a
u
to
auto
a
u
to
auto
auto
Operating Instructions
Betriebsanleitung
Notice d’utilisation
Gebruiksaanwijzing
Istruzioni sull’uso
Driftsinstruks
Driftsvejledning
Käyttöohje
Kezelési utasítás
Ðóêîâîäñòâî ïî ýêñïëóàòàöèè
Instrucciones de manejo
Instruções de operação
Οδηγίες λειτουργίας
Ýþletme kýlavuzu
Navodilo za uporabo
Uputstvo za rad
Prevádzkový návod
Provozní návod
Instrukcja obsługi
Bruksanvisning
302002027 C
Download from Www.Somanuals.com. All Manuals Search And Download.
IVB 3-H
IVB 5-H
IVB 7-H
english
Contents
1 Important safety
instructions
............................................................................................2
2 Description
2.1 Purpose................................................................................5
2.2 Operating elements..............................................................5
3 Before start-up
4 Operation
3.1 Assembling the cleaner........................................................6
4.1 Connections .........................................................................6
4.1.1 Connecting the suction hose................................................6
4.1.2 Electrical connection ............................................................6
4.1.3 Connecting electrical appliances..........................................7
4.2 Switching on the vacuum cleaner.........................................7
4.2.1 Switch position “I”.................................................................7
4.2.2 Switch position „auto“...........................................................7
4.2.3 Suction power control...........................................................7
4.3 Check volume flow monitor ..................................................7
4.4 Acoustic warning..................................................................8
4.5 Cleaning the filter element (IVB 3-H)....................................8
4.6 Cleaning the filter element (IVB 5-H/7-H).............................8
5 Applications and
techniques
5.1 Techniques ...........................................................................9
5.1.1 Picking up dry substances....................................................9
5.1.2 Picking up liquids..................................................................9
6 After finishing work
7 Maintenance
6.1 Switching the vacuum cleaner off and storage...................10
7.1 Maintenance plan...............................................................10
7.2 Maintenance work..............................................................11
7.2.1 Replacing the waste bag....................................................11
7.2.2 Replacing the filter bag.......................................................11
7.2.3 Replacing filter element „H“ (IVB 3-H)................................12
7.2.4 Replacing filter element „H“ (IVB 5-H/7-H).........................12
7.2.5 Emptying dirt tank (IVB 3-H/5-H)........................................13
7.2.6 Emptying dirt tank (IVB 7-H) ..............................................13
8 Troubleshooting
..........................................................................................14
9 Further information
9.1 Recycling the vacuum cleaner ...........................................15
9.2 Guarantee ..........................................................................15
9.3 Tests and approvals............................................................15
9.4 Technical data ....................................................................16
9.5 Accessories........................................................................16
9.6 EC declaration of conformity ..............................................16
01
Download from Www.Somanuals.com. All Manuals Search And Download.
IVB 3-H
IVB 5-H
IVB 7-H
english
1 Important safety instructions
Symbols used to mark
instructions
Before using the
vacuum cleaner,
always read the
This symbol is
used to mark
safety
instruc-
operating
structions
in-
and
tions that must
be observed to
keep them read-
prevent damage
ily available.
to the vacuum cleaner and its
performance.
This symbol is
used to mark
safety instructions
This symbol in-
dicates tips and
instructions
to
that must be ob- simplify work and to ensure safe
served to prevent operation.
damage to persons.
For your own safety
Only allow the vacuum cleaner lations. Besides the operating
to be used by persons who have instructions and the binding
been trained in its use and who accident prevention regulations
have been explicitly authorized valid in the country of use, ob-
to use it.
serve recognized regulations for
safety and proper use.
Despite its simple handling the
vacuum cleaner is not suitable Do not use any unsafe work
for children.
techniques.
The use of the vacuum cleaner
is subject to valid national regu-
Purpose and intended use
The vacuum cleaners described
in this operating manual are
suitable for
– commercial use, e.g. in
hotels, schools, hospitals,
factories, shops, offices and
rental businesses.
rettes, hot ash, etc.)
-
-
flammable, explosive, ag-
gressive liquids (e.g. petrol,
solvents, acids, alkalis, etc.)
flammable, explosive dust
(e.g. magnesium or alumini-
um dust, etc.)
– for separation of any kind
of dust with exposure limits, When dust removers are used,
including carcinogenic dust the rate at which air is ex-
and hazardous dust (dust changed in the room must be
class H).
adequate if the exhaust air from
the vacuum cleaner is blown into
Permanent filters should be the room (please observe regu-
replaced by a specialist only in lations valid in your country).
suitable rooms (e.g. contamina-
tion stations).
Before starting work, the operat-
ing staff must be informed on
The following materials should
not be picked up by the vacuum
cleaner:
-
-
use of the vacuum cleaner
risks associated with the ma-
terial to be picked up
-
safe disposal of the picked
up material.
-
hot materials (burning ciga-
02
Download from Www.Somanuals.com. All Manuals Search And Download.
IVB 3-H
IVB 5-H
IVB 7-H
english
Dust Class H (high). The ums for Dust Class H are tested
dusts which belong to in their entirety and have a max-
this class are: dusts with imum degree of permeability of
OEL values, all carcinogenic 0.005%. The disposal must be
dusts and dusts which are mixed dust free.
with pathogenic agents. Vacu-
Precautions and safety
regulations when using the
vacuum cleaner
Before start-up
Electrical components
Inspect power cord regularly Check the rated voltage of the
to detect signs of damage, e.g. vacuum cleaner before con-
cracks or ageing.
necting it to the mains supply
system. Ensure that the voltage
If the power cord is damaged, it shown on the rating plate cor-
must be replaced by Nilfisk-Ad- responds to the voltage of the
vance-Service or an electrician local mains power supply.
to avoid danger before use of
the vacuum cleaner is contin- If you are using an extension
ued.
cord, use only those specified
by the manufacturer or higher
Use only the type of power quality ones (see section 9.4
cord specified in the operating „Technical data“).
manual.
It is recommended that the
Do not damage the power cord vacuum cleaner should be con-
(e.g. by moving over it or pulling nected via a residual current
or crushing it).
circuit breaker. This stops the
supply of electricity if the leak-
Disconnect the power cord by age current to earth exceeds 30
pulling the plug only (do not pull mA for 30 ms or it has an earth
or tug the power cord).
tester circuit.
Inspect the vacuum cleaners to When using an extension lead,
ensure that they are in proper check the minimum cross-sec-
condition. Plugs and couplings tions of the cable:
in power cords must at least
Cable length
m
Cross section
have splash protection.
<16 A
<25 A
ø1.5mm² ø2.5mm²
ø2.5mm² ø4.0mm²
up to 20 m
20 to 50 m
Never use the vacuum cleaner if
the filter element is damaged.
Arrange the electrical parts
(sockets, plugs and couplings)
and lay down the extension lead
so that the protection class is
maintained.
Picking up liquids
If foam develops or liquid
emerges, stop work immediately
and empty the dirt tank.
Never spray water on to the
upper section of the vacuum
cleaner. Danger for persons,
risk or short-circuiting.
Regularly clean the built in float
(IVB 3-H) and level indicator
hose (IVB 5-H/7-H) to limit the
water level and check that they
are not damaged.
Observe the latest edition of the
IEC regulations.
See section 5 for information on
handling liquids and (hazard-
ous) dust.
03
Download from Www.Somanuals.com. All Manuals Search And Download.
IVB 3-H
IVB 5-H
IVB 7-H
english
Tool socket
Use the socket on the vacuum 2. Switch off the appliance to
cleaner for the purpose defined
in the operating instructions
only.
be connected.
CAUTION!
Follow the operating instructions
Before plugging an appliance and safety instructions for appli-
into the appliance socket: ances connected to the power
1. Switch off the vacuum clean- tool socket.
er
Maintenance, cleaning and
repair
Only carry out maintenance
work described in the operating
instructions.
pack the vacuum cleaner in
well sealed packaging
– and avoid spreading depos-
ited harmful dust.
Always pull out the mains plug
before cleaning and mainte- During maintenance and repair
nance of the vacuum cleaner.
work all contaminated parts that
could not be cleaned satisfacto-
During maintenance and clean- rily must be:
ing, handle the vacuum cleaner – packed in well sealed bags
in such a manner that there is – disposed of in a manner that
no danger for maintenance staff
or other persons.
complies with valid regula-
tions for such waste remov-
al.
In the maintenance area
– use filtered compulsory ven- A dust test must be performed at
tilation
least once every year by Nilfisk-
Advance service or a trained
– wear protective clothing
– clean the maintenance area person. This test includes, for
so that no harmful substanc- example, whether there is dam-
es get into the surroundings.
age to the filter, the vacuum
cleaner is sealed to the air and
Before removing the vacuum the control equipment works
cleaner from the area contami- properly.
nated with harmful substances:
– clean the outside of the vac-
uum cleaner, wipe it clean or
Accessories and spare parts
Use only the brushes supplied Use only original Nilfisk-Ad-
with the vacuum cleaner or vance accessories and spare
specified in the operating manu- parts (see section 9.5). The use
al. The use of other brushes can of other parts can adversely af-
adversely affect safety.
fect safety.
04
Download from Www.Somanuals.com. All Manuals Search And Download.
IVB 3-H
IVB 5-H
IVB 7-H
english
2 Description
2.1 Purpose
The vacuum cleaners IVB 3-H/ To pick up dust with maximum
IVB 5-H/IVB 7-H are suitable to room concentration values use
pick up dry, nonflammable dust, the filter bag.
nonflammbale liquids, saw-
dust and hazardous dusts with To pick up harmless dust use
maximum room concentration the waste bag. See section
values, carcinogenic dusts and 9.5 “Accessories” for ordering
other dusts containing germs number.
(dust class H).
2.2 Operating elements
See fold-out page at the front of 7 Grip to empty tank1)
these operating instructions.
8 Inlet fitting
9 Appliance socket
10 Cable hook
1 Handle
2 Suction pipe support
3 Accessory holder
4 Applicance switch with suc-
tion power control
5 Retaining clamp
6 Dirt tank
11 Operating knob for filter
cleaning1)
12 Tank locks
13 Castor with brake
14 Hose diameter setting
1)
Option depending on model
05
Download from Www.Somanuals.com. All Manuals Search And Download.
IVB 3-H
IVB 5-H
IVB 7-H
english
3 Before start-up
3.1 Assembling the cleaner
1. Open the retaining clamps
and lift off the upper section
of the cleaner.
2. Take the accessories out of
the dirt tank and the packag-
ing.
3. To pick up dust with maxi-
mum room concentration
values:
CAUTION!
On delivery some of the accesso-
ries are lying in the tank and must
be removed before the vacuum
cleaner is used for the first time.
Remove the upper section of the
vacuum cleaner:
Insert the filter bag into the
dirt tank according to the
instructions (instructions in-
cluded).
The mains plug should not be in-
serted into a socket.
To pick up harmless dust:
Insert the disposal bag (in-
structions included) into the
tank.
IMPORTANT:
P r e s s
the filter bag connection
firmly on to the inlet fitting.
4. Fit the upper section of the
vacuum cleaner and close
the retaining clamps.
NOTE:
Ensure that the
retaining clamps fit properly.
4 Operation
4.1 Connections
4.1.1 Connecting the suction
hose
1. Connect the suction hose.
The suction hose diameter must
suit the position of the switch in
order to pick up dry, nonflam-
mable dust with maximum room
concentration values.
The operating voltage shown on the
rating plate must correspond to the
voltage of the mains power supply.
4.1.2 Electrical connection
1. Ensure that the vacuum
cleaner is switched off.
2. Insert the power cord into a
properly installed and fused
socket with an earthing con-
tact.
06
Download from Www.Somanuals.com. All Manuals Search And Download.
IVB 3-H
IVB 5-H
IVB 7-H
english
To comply with regulations, only ap-
proved dust producing tools should
be connected.
The maximum power consumption
of the connected power tool is stat-
ed in section 9.4 “Technical data”.
4.1.3 Connecting electrical
appliances
1. Ensure that the electrical
appliance is switched off.
2. Connect the electrical appli-
ance to the appliance socket
on the control panel.
4.2 Switching on the
vacuum cleaner
1. Turn the switch to position
„I“.
4.2.1 Switch position “I”
The vacuum cleaner motor
starts.
0
2
3
3
2
6
7
0
0
The hose diameter and the setting
for the suction hose diameter must
be the same.
Hose
ø
Hose diameter
setting
ø27
ø32
ø38
ø50
ø27
ø32
ø38
ø50
Before switching the switch to position
„auto“, ensure that the tool connected
to the appliance socket is switched off.
4.2.2 Switch position „auto“
The hose diameter and the setting
for the suction hose diameter must
be the same.
0
2
3
3
2
7
1. Turn the switch to position
„auto“. The vacuum cleaner mo-
tor starts when the connected
appliance is switched on.
2. When the power tool is switched
off the vacuum cleaner contin-
ues to run for a short moment
so that any dust in the suction
hose is conveyed to the safety
filter bag.
0
0
Hose
ø
Hose diameter
setting
ø27
ø32
ø38
ø50
ø27
ø32
ø38
ø50
4.2.3 Suction power control
The motor speed and the suc-
tion power can be varied with
the suction power control. This
allows precise adaptation of
the suction power for different
cleaning tasks.
0
2
3
3
6
7
2
0
0
Before picking up dust with maxi-
mum room concentration values:
1. Check that all the filters are
present and properly fitted.
2. When the motor is running,
hold the suction hose shut.
An acoustic warning sounds
after approx. 1 second.
4.3 Check volume flow
monitor
07
Download from Www.Somanuals.com. All Manuals Search And Download.
IVB 3-H
IVB 5-H
IVB 7-H
english
4.4 Acoustic warning
For safety reasons, an acoustic
warning sounds if the air speed
in the suction hose drops to be-
low 20 m/s. See section “Trou-
bleshooting”.
4.5 Cleaning the filter
element (IVB 3-H)
0
x3
auto
I
1
2
NOTE:
If the acoustic signal sounds again
after repeated cleaning, replace the
filter element (see section 7.2.3).
Push & Clean
Filter Cleaning System
Only after picking up harmless dust
using the waste bag.
If suction performance drops:
cleaning three times. The re-
sulting stream of air removes
attached dust from the slats
of the filter elements.
1. Set the suction power to
maximum.
2. Close the nozzles or suction
hose opening with the palm
of your hand.
3. Press the button to start filter
4.6 Cleaning the filter
element (IVB 5-H/
IVB 7-H)
To ensure that suction performance
is always at its best, the filter ele-
ment is automatically cleaned dur-
ing operation. We recommend com-
plete cleaning if the filter element
becomes extremely dirty.
Only after picking up harmless dust
using the waste bag.
3. Turn the switch to position „I“
and let the cleaner operate
for approx. 10 seconds with
the suction hose opening
closed.
NOTE:
If the acoustic signal sounds again
after repeated cleaning, replace the
filter element (see section 7.2.4).
1. Switch off the vacuum clean-
er
2. Close the nozzles or suction
hose opening with the palm
of your hand.
08
Download from Www.Somanuals.com. All Manuals Search And Download.
IVB 3-H
IVB 5-H
IVB 7-H
english
5 Applications and techniques
5.1 Techniques
If used correctly, additional ac- Effective cleaning is achieved if
cessories, suction nozzles and you follow just a few guidelines
suction hoses can enhance the in combination with your own
cleaning action and reduce the practical experience in special
cleaning effort.
fields.
Here are some basic tips.
5.1.1 Picking up dry
substances
CAUTION:
ries” for ordering number. Dis-
Do not pick up flammable posal of the picked up material
substances.
is then simple and hygienic.
The suction hose diameter must After picking up liquids, the filter
suit the position of the switch in element is wet. A damp filter el-
order to pick up dry, nonflam- ement clogs more quickly when
mable dust with maximum room dry substances are picked up.
concentration values.
For this reason the filter element
should be washed and dried or
There must always be a safety replaced by a dry element be-
filter bag in the tank before dry fore dry substances are picked
substances with maximum room up.
concentration values are picked
up. See section 9.5 “Accesso-
ries” for ordering number.
To pick up harmless dust we
recommend the use of a waste
bag. See section 9.5 “Accesso-
5.1.2 Picking up liquids
CAUTION:
Do not pick up flammable ment or filter screen is recom-
substances.
mended.
The use of a separate filter ele-
Before liquids are picked up, al- If foam appears, stop work im-
ways remove the filter bag/waste mediately and empty the tank.
bag and check that the float (IVB
3-H) or the water level limit (IVB To reduce the amount of foam,
5-H/7-H) works properly. (See use foam killer Nilfisk-Advance
section 7.2.3 and 7.2.4 “Replac- Foam Stop (see section 9.5
ing the filter element“.)
„Optional Accessories“ for order
number).
09
Download from Www.Somanuals.com. All Manuals Search And Download.
IVB 3-H
IVB 5-H
IVB 7-H
english
6 After finishing work
6.1 Switching the vacuum
cleaner off and storage
1. After picking up hazardous
dust, vacuum clean the out-
side of the cleaner.
2. Switch off the vacuum clean-
er and pull the mains plug
out of the socket.
3. Remove the suction hose
form the vacuum cleaner and
close the inlet fitting (1) with
the plug (2).
4. Wind up the power cord and
hang it on the handle.
IVB 3-H
1
2
5. Empty the tank and clean the
vacuum cleaner.
6. After picking up liquids: Store
the upper section of the
cleaner separately so that
the filter element can dry.
7. Store the vacuum cleaner
in a dry room where it is
protected from unauthorized
use.
IVB 5-H
IVB 7-H
7 Maintenance
7.1 Maintenance plan
After finishing work
As required
7.2.1 Replacing the waste bag
7.2.2 Replacing the safety filter bag
7.2.3 Replacing filter element „H“ (IVB 3-H)
7.2.4 Replacing filter element „H“ (IVB 5-H/7-H)
7.2.5 Emptying dirt tank (IVB 3-H/IVB 5-H)
7.2.6 Emptying dirt tank (IVB 7-H)
7.2 Maintenance work
7.2.1 Replacing the waste
bag
IVB 3-H/IVB 5-H:
1
1. Open the retaining clamps
and remove the upper sec-
tion of the cleaner from the
dirt tank.
2. Carefully remove the waste
bag connection (1) from the
inlet fitting.
2
3. Close the waste bag connec-
tion with the slide (2).
4. Close the waste bag using
the cable binder (3).
Only after picking up harmless dust.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
IVB 3-H
IVB 5-H
IVB 7-H
english
5. Dispose of the dirt in accord-
ance with legal regulations.
6. Insert a new filter bag into the
cleaned tank as described in
the instructions enclosed.
3
IMPORTANT:
Press the filter bag connection
firmly on to the inlet fitting.
IVB 7-H:
1. Remove the upper section of
cleaner from the dirt tank.
2. Open the retaining clamps
(1) and remove the interme-
diate ring (2) from the tank.
3. Close the waste bag using
the cable binder (3).
2
1
1
3
4. Dispose of the dirt in accord-
ance with legal regulations.
5. Insert a new filter bag into the
cleaned tank as described in
the instructions enclosed.
IMPORTANT: Press the filter
bag connection firmly on to
the inlet fitting.
7.2.2 Replacing the safety
filter bag
1. Clean the filter element (see
4.5 and 4.6).
2. Switch off the vacuum clean-
er and wait approx. 5 minutes
so that the dust can settle in
the tank.
3. Open the retaining clamps
and remove the upper sec-
tion of the cleaner from the
dirt tank.
4. Remove the filter bag con-
nection (1) from the inlet fit-
ting.
1
2
During the following work, en-
sure that dust is not unnecessarily
spread around. Wear a P2 breath-
ing mask.
5. Close the safety filter bag
connection (2) with the slide.
6. Remove the plastic sleeve
from the tank rim and close it
using a cable binder (3).
7. Remove the safety filter bag
from the tank and dispose
of it in accordance with legal
regulations.
3
8. Insert a new safety filter bag
into the tank according to the
instructions (in the filter bag
packaging).
IMPORTANT:
Press the filter bag connection
on the inlet fitting as far as pos-
sible.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
IVB 3-H
IVB 5-H
IVB 7-H
english
Never use the vacuum cleaner with-
out a filter.
7.2.3 Replacing filter element
„H“ (IVB 3-H)
3. Open the retaining clamps and
remove the upper section of the
cleaner from the dirt tank. Lay
the upper section of the cleaner
down with the filter element fac-
ing upwards.
4. Using the enclosed tool (2), turn
the filter holder (1) anticlockwise
and remove it.
1. Clean the filter element (see
4.5).
ensure that dust is not 2. Switch off the vacuum clean-
During the following work,
unnecessarily
around. Wear
spread
P2
er and wait approx. 5 minutes
so that the dust can settle in
the tank.
a
breathing mask.
5. Place the protective filter bag
over the filter element (3).
6. Carefully remove the filter ele-
ment and close the protective
filter bag with a knot.
3
1
2
7. Clean the filter seal (4). Check it
for damage and replace it if nec-
essary.
8. Check the antistatic clamp (5)
for damage and have it replaced
by Nilfisk-Advance Service if
necessary.
4
9. Fit a new filter element.
10.Check that the float (6) works
properly. When the filter holder
is turned, the float inside must
move about easily.
6
11.Using the enclosed tool, attach
the filter holder and turn it clock-
wise to lock it.
12.Dispose of the used filter ele-
ment in accordance with legal
regulations.
5
7.2.4 Replacing filter element
„H“ (IVB 5-H/7-H)
P2 breathing mask.
Never use the vacuum cleaner with-
out a filter.
cleaner down with the filter ele-
ment facing upwards. Do not
place the upper section of the
cleaner on the guard (1) and do
not damage the filter element.
2. Unscrew the screw (2), open the
bar handle and remove it.
3. Remove the filter holder (3).
4. Place the protective filter bag
over the filter element.
5. Carefully remove the filter ele-
ment and close the protective
filter bag with a knot.
6. Clean the filter seal (4). Check it
for damage and replace it if nec-
essary.
During the following
work, ensure that dust
is not unnecessarily
spread around. Wear a
1. Remove the upper section
of cleaner from the dirt tank.
Lay the upper section of the
1
3
2
4
7. Check the antistatic clamp (5)
for damage and have it replaced
by Nilfisk-Advance Service if
necessary.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
IVB 3-H
IVB 5-H
IVB 7-H
english
8. Check that the control flap (6)
for filter cleaning works properly.
The control flap should move
back and forwards easily.
6
7
9. Clean the level hose (7).
10.Fit a new filter element.
11.Fit the filter holder. Ensure that it
is in the correct position.
12.Fit bar and close bar handle.
13.Dispose of the used filter ele-
ment in accordance with legal
regulations.
5
7.2.5 Emptying dirt tank
(IVB 3-H/IVB 5-H)
1. Remove the upper section of
cleaner from the dirt tank.
2. Using one hand, take hold of the
dirt tank underneath and tip out
the dirt.
3. Dispose of the dirt in accordance
with legal regulations.
4. Clean the rim of the tank before
fitting the upper section of clean-
er.
Before reinserting the suction hose:
5. Clean the inlet fitting and hose
collar.
Only after picking up harmless dust
without a filter bag.
7.2.6 Emptying the dirt tank (IVB 7-H)
1. Remove the upper section of
cleaner from the dirt tank.
2. Open the retaining clamps
(1) and remove the interme-
diate ring (2) from the tank.
3. Pull the lever in the handle
(3) upwards and tilt the tank.
4. Tip out the collected dirt.
5. Dispose of the dirt in accord-
ance with legal regulations.
or:
3. Open the tank locks (4).
4. Use the handles (5) to lift the
tank out of the frame.
5. Tip out the collected dirt.
6. Place the empty tank in the
frame and close the locks
(4).
2
1
1
3
Only after picking up
harmless dust with-
out a filter bag.
5
4
To empty the dirt
tank after picking
up liquids: remove
4
7. Dispose of the dirt in accord-
ance with legal regulations.
5
the intermediate ring as a proper
seal is only ensured during suction.
After emptying the tank: clean the
rim of the tank and the seals in the
intermediate ring and the upper
section of cleaner before refitting
them.
be reduced.
If the seal or groove is dirty or dam-
aged, the suction performance will
Before reinserting the suction hose:
clean the inlet fitting and hose collar.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
IVB 3-H
IVB 5-H
IVB 7-H
english
8 Troubleshooting
Fault
Cause
Remedy
‡ Motor does not start
> Fuse of the mains socket has • Connect mains fuse.
blown.
> Overload protection switch • Switch off the vacuum cleaner
has tripped.
and allow it to cool for approx.
5 minutes. If the cleaner can-
not be started again, contact
the Nilfisk-Advance service
department.
> Self-acting carbon brush is • Have carbon brushes changed
worn. by Nilfisk-Advance Service.
‡ Motor does not run in auto- > Power tool is defective or not • Check that the power tool
matic mode
connected properly.
works or that the plug is inser-
ted correctly.
> The power rating of the elec- • Note that minimum power ra-
trical tool is too low. ting is P>40W
warning > Suction power selected with • Set suction power in accor-
‡ The
acoustic
sounds. (Reduced suction
power)
suction power control is too
low.
dance with section 4.2.3. „Set-
ting suction power“.
> Hose diameter is not right for • Set correct switch position for
switch position. hose diameter.
> Clogged suction hose/nozzle. • Clean suction hose/nozzle
> The safety filter bag is full.
•
See section 7.2.2 „Replacing
filter bag“.
> Filter element is clogged.
•
See section 4.5 „Cleaning filter
element“ and 7.2.3 „Replacing
filter element“.
> Defective cleaning mecha-
nism
•
Contact Nilfisk-Advance Serv-
ice
‡ No suction power during > Tank is full. (Float is blocking • Switch off the cleaner. Empty
wet cleaning
the suction opening).
the tank.
‡ The vacuum cleaner swit- > Tank is full.
•
Switch off the cleaner. Empty
the tank.
ches off during wet clea-
ning
‡ Voltage fluctuations
> Impedance of power supply is • Connect the cleaner to another
too high.
socket closer to the fuse box.
Voltage fluctuations over 7%
should not occur if the impe-
dance at the transfer point is
≤ 0.15 Ω .
14
Download from Www.Somanuals.com. All Manuals Search And Download.
IVB 3-H
IVB 5-H
IVB 7-H
english
9 Further information
9.1 Recycling the vacuum
cleaner
Make the old cleaner unusable and electronic appliances, used
immediately. electrical goods must be col-
1. Unplug the cleaner and cut lected separately and recycled
the power cord. ecologically.
Do not discard of electrical ap- Contact your local authorities or
pliances with household waste.
your nearest dealer for further
information.
As specified in European Direc-
tive 2002/96/EC on old electrical
9.2 Guarantee
Our general conditions of busi-
ness are applicable with regard
to the guarantee. Subject to
change as a result of technical
advances.
9.3 Tests and approvals
The vacuum cleaners have been A dust test must be performed
tested as specified in IEC/EN at least once every year by the
60335-2-69 including appendix manufacturer or a trained per-
AA. All the requirements were son. This test covers, for exam-
fulfilled for equipment in dust ple, whether there is damage to
class H.
the filter, the vacuum cleaner is
sealed to the air and the control
The vacuum cleaners must be equipment works properly.
inspected regularly in accord-
ance with national accident pre-
vention regulations (in Germany
as specified in VBG 4 and DIN
VDE 0701 Part 1 and Part 3, at
regular intervals and after re-
pairs or modifications).
15
Download from Www.Somanuals.com. All Manuals Search And Download.
IVB 3-H
IVB 5-H
IVB 7-H
english
9.4 Technical data
IVB
3-H
5-H
7-H
GB
230/240V
GB
110V
GB
230/240V
GB
110V
GB
230/240V
GB
110V
EU
EU
EU
Voltage
V
230
230/240
13
110
230
230/240
50/60
13
110
230
230/240
13
110
Mains frequency
Fuse
Hz
A
16
16
16
16
Power consumption
W
1200
Connected load for
appliance socket
W
2400
3600
1800
3000
560
2400
3600
1800
560
2400
3600
1800
3000
560
Total connected load
Air flow rate
W
1760
3000
3600
1760
1760
l/min
Vacuum
mbar/kPa
230/23
Measurement area sound
pressure level at a distance of 1 dB(A)
m, EN 60704-1
62
59
60
57
Sound level
dB(A)
m
Power cord: Length
7.5
H07BQ-
F3G1.5
H07BQ-
F3G1.5
H07BQ-
F3G1.5
Power cord: Type
H05RR- F3G1.5
H05RR- F3G1.5
I
H05RR- F3G1.5
Protection class
Type of protection
(splash water protec-
ted)
IP X4
Radio interference level
Tank volume
Width
EN 55014-1
l
27
380
390
570
10
45
476
506
655
14
70
580
605
970
27
mm
mm
mm
kg
Depth
Height
Weight
Suction hose diameter
mm
Minimum air flow volume
l/min
Associated negative pressure
between suction hose/tool
Pa
27
32
38
50
690
970
16300
15700
13900
7800
1360
2360
9.5 Optional accessories
9.6 EC declaration of conformity
Description
IVB 3-H
Order No.
IVB 5-H
IVB 7-H
EC declaration of conformity
Safety filter bag
302001910 302001143 302001912
(5 pcs.)
NILFISK-ADVANCE A/S
Sognevej 25
DK-2605 Brøndby
Waste bag (5 pcs.)
Filter element „H“
302001310 302001311 302001480
302000462
302001137
30082
Product:
Model:
Vacuum cleaner for wet and dry operation
IVB 3-H/5-H/7-H
Protective filter bag
(10 pcs.)
Description:
110/230-240 V~, 50/60 Hz, 1200 W, Dust class H
Filter screen
15475
–
The design of the appliance
corresponds to the following
pertinent regulations:
EC Machine Directive 98/37/EC
EC Low Voltage Directive 73/23/EC
EC EMC Directive 2004/108/EC
Cloth insert filter
302001370
302001371
Nilfisk-Alto-Foam-Stop
(6 x 1 l)
8469
Applied harmonized standards:
EN 12100-1, EN 12100-2
EN 60335-1
EN 60335-2-69
EN 55014-1, EN 55014-2, EN 61000-3-2
Applied national standards and
technical specifications:
DIN EN 60335-1
DIN EN 60335-2-69
Jørgen Jensen
Brøndby, 04.07.2005
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Nilfisk-Advance A/S
Sognevej 25
DK-2605 Brøndby
Denmark
Tel.: +45 43 23 81 00
Fax: +45 43 43 77 00
Download from Www.Somanuals.com. All Manuals Search And Download.
|