NewAir Air Conditioner AC 10000E User Manual

PLEASE READ AND SAVE THESE INSTRUCTIONS  
NewAir AC-10000E, AC-10000H  
Portable Air Conditioner  
Owner’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FOR MAXIMUM EFFICENCY:  
Make sure doors and windows are closed while the portable air conditioner is in use.  
Also keep curtains and blinds closed during the sunniest parts of the day while it is in  
operation.  
Frequently clean the filters.  
Once the room or area has reached your desired comfort level, be sure to reduce the  
unit’s temperature and ventilation settings.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS LIST  
Front  
Back  
FIG.6  
FIG.5  
1.  
2.  
3.  
4.  
5.  
6.  
Display window  
7.  
8.  
9.  
Cord wrap  
Air filter  
Air inlet  
Control panel  
Control buttons  
Louvers  
Carrying handle  
Casters  
10. Exhaust air outlet  
11. Air inlet  
12. Water plug/drainage port  
Accessories  
13. Hose adaptor (goes over hose and  
into the window kit)  
14. Exhaust hose  
15. Activated carbon filter  
16. Extendable window kit  
17. Hose for continuous drainage  
18. Remote control  
FIG.7  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION INSTRUCTIONS  
Installing the Exhaust Hose  
FIG.8  
1. Open the window and insert the window kit into the open gap.  
2. Close the window until the window kit is held securely. You may need to adjust the  
size of the window kit and secure it with screws. This technique may also be used  
for sash windows.  
3. Fit the exhaust hose into the exhaust air outlet located at the back of the air  
conditioner.  
4. Attach the hose adapter onto the exhaust hose.  
5. Attach the hose adapter to the window kit.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Positioning the Exhaust Hose  
Insert the exhaust hose into  
the back of the unit and tighten  
it into place.  
Avoid kinks and bends in the  
exhaust hose. These can  
cause expelled moist air to  
accumulate, resulting in  
FIG. 9  
overheating and unexpected  
shut offs (See Fig 9 & 10).  
Τhe exhaust hose may be  
extended from 12 inches (300  
mm) to 59 inches (1500 mm),  
but for maximum cooling  
efficiency, use the shortest  
length possible.  
FIG. 10  
FIG. 11  
WARNING:  
The included exhaust hose is  
specially designed to fit the  
specifications of this unit. Do not  
extend it with your own hose, as  
this can cause the air conditioner to  
malfunction.  
FIG. 12  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the Activated Carbon Filter  
1. Remove the filter frame from the  
unit.  
2. Remove the activated carbon filter  
from its plastic bag.  
3. Insert the activated carbon filter  
into the back of the unit.  
4. Reattach the filter frame onto the  
unit.  
FIG.13  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
Control Panel  
FIG.14  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
8.  
9.  
ON/OFF (power) button  
Timer button  
10. Heating mode indicator light (only for  
AC-10000H)  
Timer indicator light  
11. Fan mode indicator light  
12. Cooling mode indicator light  
13. Automatic mode indicator light  
14. Mode selection button  
15. Fan speed (ventilation) button  
16. Display window  
Temperature increase button  
Compressor indicator light  
Full water tank indicator light  
Temperature decrease button  
Low ventilation indicator light  
High ventilation indicator light  
17. Remote control receiver  
Turning the Unit On and Off  
1. Press the ON/OFF button. The unit will start automatically. If the ambient temperature is:  
- Higher than 74°F, the unit will operate in cooling mode.  
- Higher than 68°F but below or equal to 74°F, the unit will operate in fan mode.  
- Equal to or below 68°F, the unit will operate in heating mode (heating mode is only  
available on model # AC-10000H).  
2. The indicator lights showing any functions will turn on. Please note that the display window  
will only show ambient room temperatures ranging from 32°F to 122°F.  
3. To turn the unit off, press the ON/OFF button again.  
Setting the Mode/Function  
1. Press the MODE button to select the desired mode (cooling, heating, fan or automatic).  
2. The selected mode’s indicator light will turn on.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting the Temperature  
1.  
2.  
Press the UP or DOWN button to change the set temperature.  
The display window will then indicate the set temperature. If no temperature is set, the  
display will show the room’s ambient temperature.  
3.  
Please note that the default cooling temperature of this portable air conditioner is 75o F.  
Setting the Fan/Ventilation Speed  
1.  
Press the SPEED button to select the desired fan speed (high or low). The appropriate  
indicator light (high or low) will turn on accordingly.  
2.  
If the unit is in AUTO mode, the fan speed will be automatically set according to the ambient  
temperature (the appropriate indicator light will turn on). Please note that when the unit is  
in AUTO mode, the speed setting cannot be changed.  
Setting the Timer  
1.  
Press the TIMER button to set the desired number of operating hours (from 1 to 12 hours).  
When the set time has been reached, the machine will automatically turn off. The display  
window will show the number of hours being set as you press the TIMER button. If the  
TIMER is not set, the unit will work continuously.  
2.  
By pressing the TIMER button without selecting any other modes or settings, you can set  
the number of hours to be delayed before the unit turns on. For example, if you press the  
TIMER to “2”, the unit will automatically turn on after 2 hours.  
Heating Mode (only for model no. AC-10000H)  
When the air conditioner is in heating mode, ambient warm air is recycled and used to heat your  
immediate area. The exhaust pipe will still need to be fitted onto the unit in order for the  
cold air to be removed. When in heating mode, the machine can be set on HIGH or LOW  
speed.  
All of the above functions can also be performed with  
the included remote control.  
The remote control requires 2 AAA batteries to operate.  
FIG. 15  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Regulating the Air Flow Direction  
To control the air flow direction, adjust the knob  
on the louvers.  
FIG. 16  
PLEASE NOTE:  
1. To prolong the life of the compressor, after turning off the unit, please wait at least 3  
minutes before turning it back on.  
2. The cooling system will switch off if the ambient temperature is lower than the set  
temperature (the ventilation will keep working at the set level). If the ambient  
temperature rises above the selected level, cooling will resume.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
DRAINING THE UNIT  
During the cooling process, some water will be extracted from the air and stored within the  
unit’s water reservoir.  
If the water reservoir is full, both the compressor and motor will stop and the unit will beep  
(press any button to stop the beeping sound). The full water tank indicator light will also  
start flashing.  
To resume cooling, empty the reservoir by following these steps:  
1. Turn off the air conditioner and unplug it  
from the wall socket. To prevent water  
leakage, avoid moving the unit when full.  
2. Place a container (such as a small pan)  
underneath the drainage port.  
3. Remove the water plug from the drainage  
port and allow the water to drain out.  
4. When the container is almost full, replace  
the water plug back into the drainage port  
and empty the water container.  
Water plug  
Cap for the  
5. Repeat until the water reservoir is  
completely empty.  
water plug  
Drainage port  
6. Replace the water plug back into the  
drainage port and make sure it is firmly in  
place.  
FIG.17  
7. Turn the unit back on. The warning signal  
should be off.  
For Continuous Drainage  
Remove the water plug from the drainage  
port and retain it for future use.  
FIG.18  
Connect the drainage hose included with  
unit to the drainage port as shown.  
Connect the other end of the hose into a  
drain.  
Water plug  
Cap for the  
water plug  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The drainage hose may be extended by  
adding an extension hose using a suitable  
connector.  
FIG.19  
Drainage hose  
included with the unit  
PLEASE NOTE:  
1. The drain must be at or below the level  
of the drainage port.  
FIG.20  
2. The full water tank indicator light will not  
work when the unit is being  
continuously drained.  
Drainage hose  
included with the unit  
3. To extend the drainage hose, you can  
connect it with another hose with an  
overall diameter of 0.7” (18 mm).  
4. If room humidity levels are over 85%, it  
will be necessary to continuously drain  
the unit using the drainage hose.  
Extension hose (OD: 0.7” )  
For Heating Mode (only for model no. AC-10000H)  
While using the heating function, please note the following:  
1. In order to properly exhaust cool air, make sure the exhaust hose and window kit are  
properly installed (refer to page 4 for instructions).  
2. Set up the air conditioner for continuous drainage using the drain tube (refer to page 10 &  
11 for instructions).  
The working range for the heating function is 32° F to 68°F. The unit may not provide optimal  
heating if used in temperatures outside this range  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE INSTRUCTIONS  
Always unplug the air conditioner from the power supply before cleaning.  
To maximize the efficiency of the air conditioner, regularly clean the unit.  
Cleaning the Housing  
Use a soft, damp cloth to wipe the body clean.  
Never use strong chemicals, gasoline, detergents, chemically-treated cloths, or any other  
cleaning solutions to clean the air conditioner, as these can all potentially damage the unit’s  
housing.  
Cleaning the Filters:  
Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters  
and then rinse them thoroughly under running water (no warmer than 104oF).  
Thoroughly dry the filters before replacing them back into the unit.  
PLEAE NOTE:  
Never operate the unit without the filters.  
End of Season Storage  
Completely drain any condensed water  
from the unit.  
Set the air conditioner on fan mode  
(ventilation only) for a few hours to  
thoroughly dry the inside of the unit.  
Clean or change the filter.  
Unplug and wrap the power cord around  
the cord wrap as shown (fig. 21).  
Place the unit back in its original carton  
and store it in a clean, dry area.  
FIG.21  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
The air conditioner does not function. ꢀ  
Is the air conditioner plugged in?  
Is the power outlet functioning correctly?  
Is the full water tank indicator light flashing?  
Is the ambient room temperature lower than the  
set temperature?  
The unit does not produce adequate ꢀ  
cooling.  
Is the unit placed in direct sunlight? If so, close  
any curtains or move the unit to a more shaded  
area.  
Are too many windows or doors open?  
Are there too many people in the room?  
Are there additional heat sources in the room?  
Is the filter dusty or dirty?  
Is the air inlet or air outlet blocked?  
Is the ambient room temperature lower than the  
set temperature?  
The unit is noisy.  
Is the machine positioned unevenly?  
Is the unit positioned on an even, solid surface?  
The compressor does not work. ꢀ  
Is the compressor’s overheat protection function  
activated? If so, wait for the temperature to  
drop and then turn on the unit again.  
Never try to repair and dismantle the unit yourself. Unauthorized repairs can  
void your warranty and endanger the user.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TECHNICAL SPECIFICATIONS  
Model Number:  
AC-10000E  
AC-10000H  
830W / 7.6A  
Voltage / Frequency  
115V / 60Hz  
909W / 8.3A  
Power Consumption for cooling”  
Power Consumption for heating”  
Air Volume (Maximum Speed)  
Dehumidification Capacity  
Compressor Type  
NIL  
300 m3/h  
2.1 pints/hr (1 L/hr)  
Rotary  
Refrigerant Type  
R-410A  
Number of Fan Speeds  
Timer  
2
1 ~ 12 hours  
Exhaust Pipe Dimensions  
Product Weight  
Ø4.72” X 59.06” (Ø120x1500 mm)  
50.7 lbs (23kg)  
Product Dimensions (W x D x H)  
12.2” x 13.8” x 28”  
( 310 x 350 x 710 mm )  
ADDITIONAL REMARKS:  
1. The data marked with '*' may vary for technical reasons; for more accurate data, please refer  
to the rating label found on the back of the unit.  
2. Measuring condition for the above specifications:  
Cooling –DB = 95°F (35°C), WB= 82.94°F (28.3° C)  
Heating – DB= 68°F (20°C) , WB= 59°F (15°C)  
* D.B. = dry bulb temperature = room temperature  
* W.B. = wet bulb temperature = relative humidity  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIMITED MANUFACTURER’S WARRANTY  
This appliance is covered by a limited manufacturer’s warranty. For one year from the  
original date of purchase, the manufacturer will repair or replace any parts of this appliance  
that prove to be defective in materials and workmanship, provided the appliance has been  
used under normal operating conditions as intended by the manufacturer.  
Warranty Terms:  
During the first year, any components of this appliance found to be defective due to  
materials or workmanship will be repaired or replaced, at the manufacturer’s discretion, at  
no charge to the original purchaser. The purchaser will be responsible for any removal or  
transportation costs.  
Warranty Exclusions:  
The warranty will not apply if damage is caused by any of the following:  
Power failure  
Damage in transit or when moving the appliance  
Improper power supply such as low voltage, defective household wiring or  
inadequate fuses  
Accident, alteration, misuse or abuse of the appliance such as using non-approved  
accessories, inadequate air circulation in the room or abnormal operating conditions  
(extreme temperatures)  
Use in commercial or industrial applications  
Fire, water damage, theft, war, riot, hostility or acts of God such as hurricanes,  
floods, etc.  
Use of force or damage caused by external influences  
Partially or completely dismantled appliances  
Obtaining Service:  
When making a warranty claim, please have the original bill of purchase with purchase  
date available. Once confirmed that your appliance is eligible for warranty service, all  
repairs will be performed by a NewAir™ authorized repair facility. The purchaser will be  
responsible for any removal or transportation costs. Replacement parts and/or units will be  
new, re-manufactured or refurbished and is subject to the manufacturer’s discretion.  
For technical support and warranty service, please call 1-855-9Newair or email  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Ventilation Hood DA408 User Manual
Milwaukee Drill Sries 6521 User Manual
Milwaukee Impact Driver 2450 20 User Manual
New Balance Headphones NB439 User Manual
Olivetti Copier 3501 User Manual
Oregon Scientific Camcorder ATC9K User Manual
Oster Oven TSSTTVRBO4 User Manual
Panasonic All in One Printer 135FP User Manual
Panasonic Flat Panel Television BT LH1710E User Manual
Patton electronic Network Card 1050patton User Manual