Important Information
Warranty
The NI PXIe-1065 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced
by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the
warranty period. This warranty includes parts and labor.
The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects in
materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other documentation. National Instruments
will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects
during the warranty period. National Instruments does not warrant that the operation of the software shall be uninterrupted or error free.
A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before any
equipment will be accepted for warranty work. National Instruments will pay the shipping costs of returning to the owner parts which are covered by
warranty.
National Instruments believes that the information in this document is accurate. The document has been carefully reviewed for technical accuracy. In
the event that technical or typographical errors exist, National Instruments reserves the right to make changes to subsequent editions of this document
without prior notice to holders of this edition. The reader should consult National Instruments if errors are suspected. In no event shall National
Instruments be liable for any damages arising out of or related to this document or the information contained in it.
EXCEPT AS SPECIFIED HEREIN, NATIONAL INSTRUMENTS MAKES NO WARRANTIES, EXPRESS OR IMPLIED, AND SPECIFICALLY DISCLAIMS ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. CUSTOMER’S RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF NATIONAL
INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER. NATIONAL INSTRUMENTS WILL NOT BE LIABLE FOR DAMAGES RESULTING
FROM LOSS OF DATA, PROFITS, USE OF PRODUCTS, OR INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF ADVISED OF THE POSSIBILITY THEREOF. This limitation of
the liability of National Instruments will apply regardless of the form of action, whether in contract or tort, including negligence. Any action against
National Instruments must be brought within one year after the cause of action accrues. National Instruments shall not be liable for any delay in
performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunctions, or service
failures caused by owner’s failure to follow the National Instruments installation, operation, or maintenance instructions; owner’s modification of the
product; owner’s abuse, misuse, or negligent acts; and power failure or surges, fire, flood, accident, actions of third parties, or other events outside
reasonable control.
Copyright
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying,
recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National
Instruments Corporation.
National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other
intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only
to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.
Trademarks
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section
on ni.com/legal for more information about National Instruments trademarks.
Other product and company names mentioned herein are trademarks or trade names of their respective companies.
Members of the National Instruments Alliance Partner Program are business entities independent from National Instruments and have no agency,
partnership, or joint-venture relationship with National Instruments.
Patents
For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software,
the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents.
WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS
(1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL OF
RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN
ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT
INJURY TO A HUMAN.
(2) IN ANY APPLICATION, INCLUDING THE ABOVE, RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE
IMPAIRED BY ADVERSE FACTORS, INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY,
COMPUTER HARDWARE MALFUNCTIONS, COMPUTER OPERATING SYSTEM SOFTWARE FITNESS, FITNESS OF COMPILERS
AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION, INSTALLATION ERRORS, SOFTWARE AND HARDWARE
COMPATIBILITY PROBLEMS, MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL DEVICES,
TRANSIENT FAILURES OF ELECTRONIC SYSTEMS (HARDWARE AND/OR SOFTWARE), UNANTICIPATED USES OR MISUSES, OR
ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER (ADVERSE FACTORS SUCH AS THESE ARE HEREAFTER
COLLECTIVELY TERMED “SYSTEM FAILURES”). ANY APPLICATION WHERE A SYSTEM FAILURE WOULD CREATE A RISK OF
HARM TO PROPERTY OR PERSONS (INCLUDING THE RISK OF BODILY INJURY AND DEATH) SHOULD NOT BE RELIANT SOLELY
UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE. TO AVOID DAMAGE, INJURY, OR DEATH,
THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO PROTECT AGAINST SYSTEM FAILURES,
INCLUDING BUT NOT LIMITED TO BACK-UP OR SHUT DOWN MECHANISMS. BECAUSE EACH END-USER SYSTEM IS
CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS' TESTING PLATFORMS AND BECAUSE A USER OR APPLICATION
DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT
EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY
RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER
NATIONAL INSTRUMENTS PRODUCTS ARE INCORPORATED IN A SYSTEM OR APPLICATION, INCLUDING, WITHOUT
LIMITATION, THE APPROPRIATE DESIGN, PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.
Download from Www.Somanuals.com. All Manuals Search And Download.
About This Manual
Chapter 1
Getting Started
Unpacking......................................................................................................................1-1
Optional Equipment.......................................................................................................1-5
Rack Mount Kit...............................................................................................1-5
PXI Express Peripheral Slots...........................................................................1-8
System Timing Slot.........................................................................................1-8
PXI Trigger Bus ..............................................................................................1-10
PXIe_SYNC_CTRL........................................................................................1-14
Chapter 2
Providing Adequate Clearance........................................................................2-2
Setting Fan Speed............................................................................................2-5
Installing Filler Panels.....................................................................................2-5
Installing Slot Blockers ...................................................................................2-5
Rack Mounting ..............................................................................................................2-5
Connecting Safety Ground.............................................................................................2-5
Connecting to Power Source..........................................................................................2-6
© National Instruments Corporation
v
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Installing a PXI Express System Controller.................................................................. 2-6
Power Inhibit Switch LED Indicator............................................................................. 2-10
Inhibit Mode Switch...................................................................................................... 2-12
PXI_CLK10 Rear Connectors....................................................................................... 2-12
PXI Express System Configuration with MAX ............................................................ 2-12
Trigger Configuration in MAX....................................................................... 2-14
Chapter 3
Replacing the Modular Power Supply........................................................................... 3-3
Removal .......................................................................................................... 3-3
Configuration .................................................................................................. 3-4
Connecting Safety Ground.............................................................................. 3-4
Connecting to Power Source........................................................................... 3-4
Appendix A
Specifications
Appendix B
Pinouts
Technical Support and Professional Services
Glossary
Index
NI PXIe-1065 User Manual
vi
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
About This Manual
The NI PXIe-1065 User Manual describes the features of the NI PXIe-1065
chassis and contains information about configuring the chassis, installing
the modules, and operating the chassis.
Conventions
The following conventions are used in this manual:
»
The » symbol leads you through nested menu items and dialog box options
to a final action. The sequence File»Page Setup»Options directs you to
pull down the File menu, select the Page Setup item, and select Options
from the last dialog box.
This icon denotes a note, which alerts you to important information.
This icon denotes a caution, which advises you of precautions to take to
avoid injury, data loss, or a system crash. When this symbol is marked on
the product, refer to the Read Me First: Safety and Radio-Frequency
Interference document, shipped with the product, for precautions to take.
bold
Bold text denotes items that you must select or click in the software, such
as menu items and dialog box options. Bold text also denotes parameter
names.
italic
Italic text denotes variables, emphasis, a cross-reference, or an introduction
to a key concept. Italic text also denotes text that is a placeholder for a word
or value that you must supply.
monospace
Text in this font denotes text or characters that you should enter from the
keyboard, sections of code, programming examples, and syntax examples.
This font is also used for the proper names of disk drives, paths, directories,
programs, subprograms, subroutines, device names, functions, operations,
variables, filenames, and extensions.
© National Instruments Corporation
vii
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
About This Manual
Related Documentation
The following documents contain information that you might find helpful
as you read this manual:
•
IEEE 1101.1-1991, IEEE Standard for Mechanical Core
Specifications for Microcomputers Using IEC 603-2 Connectors
•
IEEE 1101.10, IEEE Standard for Additional Mechanical
Specifications for Microcomputers Using IEEE 1101.1 Equipment
Practice
•
•
•
PICMG EXP.0 R1.0 CompactPCI Express Specification,
PCI Industrial Computers Manufacturers Group
PCI Express Base Specification, Revision 1.1, PCI Special Interest
Group
PXI-5 PXI Express Hardware Specification, Revision 1.0,
PXI Systems Alliance
NI PXIe-1065 User Manual
viii
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
1
Getting Started
This chapter describes the key features of the NI PXIe-1065 chassis and
lists the kit contents and optional equipment you can order from National
Instruments.
Unpacking
Carefully inspect the shipping container and the chassis for damage. Check
for visible damage to the metal work. Check to make sure all handles,
hardware, and switches are undamaged. Inspect the inner chassis for any
possible damage, debris, or detached components. If damage appears to
have been caused during shipment, file a claim with the carrier. Retain the
packing material for possible inspection and/or reshipment.
What You Need to Get Started
The NI PXIe-1065 chassis kit contains the following items:
❑ NI PXIe-1065 chassis
❑ Filler panels
❑ AC power cable—refer to Table 1-1 for AC power cables
❑ NI PXIe-1065 User Manual
❑ Software media with PXI Platform Services 2.0 or higher
❑ Read Me First: Safety and Radio-Frequency Interference
❑ Chassis number labels
© National Instruments Corporation
1-1
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Getting Started
Table 1-1. AC Power Cables
Reference Standards
Power Cable
Standard 120 V (USA)
Switzerland 220 V
ANSI C73.11/NEMA 5-15-P/IEC83
SEV
Australia 240 V
AS C112
Universal Euro 230 V
North America 120 V
United Kingdom 230 V
CEE (7), II, IV, VII IEC83
ANSI C73.20/NEMA 5-15-P/IEC83
BS 1363/IEC83
If you are missing any of the items listed in Table 1-1, or if you have the
incorrect AC power cable, contact National Instruments.
Key Features
The NI PXIe-1065 chassis combines a high-performance 18-slot
PXI Express backplane with a high-output power supply and a structural
design that has been optimized for maximum usability in a wide range
of applications. The chassis’ modular design ensures a high level of
maintainability, resulting in a very low mean time to repair (MTTR).
The NI PXIe-1065 chassis fully complies with the PXI-5 PXI Express
Hardware Specification, offering advanced timing and synchronization
features.
The key features of the NI PXIe-1065 chassis include the following:
High Performance for Instrumentation Requirements
•
Up to 1 GB/s (single direction) per PXI Express slot dedicated
bandwidth (x4 PCIe)
•
•
30 W per slot cooling meets increased PXIe cooling requirements
Low-jitter internal 10 MHz reference clock for PXI slots with
25 ppm stability
•
Low-jitter internal 100 MHz reference clock for PXIe slots with
25 ppm stability
Quiet operation for 0 to 30 °C at 43.6 dBA
NI PXIe-1065 User Manual
1-2
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Getting Started
•
•
•
Variable speed fan controller optimizes cooling and acoustic emissions
Remote power-inhibit control
Complies with PXI and CompactPCI Specifications
High Reliability
•
•
•
•
0 to 55 °C extended temperature range
Power supply, temperature, and fan monitoring
HALT tested for increased reliability
Field replaceable power supply shuttle
Multi-Chassis Support
•
•
•
PXIe System Timing Slot for tight synchronization across chassis
Rear CLK10 I/O connectors
Switchless CLK10 routing
Optional Features
•
•
•
•
•
Front and rear rack-mount kits
Replacement power supply shuttle
EMC filler panels
Slot blockers for improved cooling performance
Factory installation services
© National Instruments Corporation
1-3
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Getting Started
Chassis Description
Figures 1-1 and 1-2 show the key features of the NI PXIe-1065 chassis
front and back panels. Figure 1-1 shows the front view of the
NI PXIe-1065. Figure 1-2 shows the rear view of the NI PXIe-1065.
2
3
4
NI PXIe-1065
5
1
13
H
1
2
3
4
5
6
7
8
9
10
11 H
12 H
13 H
14
15
16
17
18
12
5
10
6
8
9
8
7
6
11
1
2
3
4
5
6
7
Chassis Carry Handle
Backplane Connectors
PXI Filler Panels
Chassis Model Name
Removable Feet
PXI Peripheral Slots (9x)
PXI Express System Timing Slot
8
9
PXI Express Hybrid Peripheral Slots (4x)
PXI Express Peripheral Slots (3x)
10 PXI Express System Controller Slot
11 Power Inhibit Switch
12 Power Inhibit Switch LED
13 System Controller Expansion Slots
Figure 1-1. Front View of the NI PXIe-1065 Chassis
NI PXIe-1065 User Manual
1-4
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Getting Started
6
7
3
4
5
4
8
9
10
2
1
11
12
13
4
4
14
1
2
3
4
5
6
7
Universal AC Input
8
Remote Inhibit and Voltage Monitoring Connector
Inhibit Mode Selector Switch
Push-Reset Circuit Breaker
Chassis Ground Screw
Fan Guard Retainer Screws
Power Supply Shuttle ID Label
10 MHz REF OUT BNC
10 MHz REF IN BNC
9
10 Fan Speed Selector Switch
11 Power Supply Shuttle Mounting Screws (10x)
12 Power Supply Shuttle Handle (2x)
13 Power Supply Shuttle
14 Fan Guard
Figure 1-2. Rear View of the NI PXIe-1065 Chassis
Optional Equipment
Contact National Instruments to order the following options for the
NI PXIe-1065 chassis.
EMC Filler Panels
Optional EMC filler panel kits are available from National Instruments.
There are two optional kits for mounting the PXIe-1065 chassis into a rack.
The first option is a pair of mounting brackets for use on the front of the
chassis. The second option is a rear rack mount kit. The rear rack mount kit
differs from the front kit to allow for easier installation into the rack.
For more information, refer to Figure A-3, NI Chassis Rack Mount Kit
Components.
© National Instruments Corporation
1-5
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Getting Started
Slot Blockers
Optional slot blocker kits are available from National Instruments for
improved thermal performance when all slots are not used.
NI PXIe-1065 Chassis Backplane Overview
This section provides an overview of the backplane features for the
NI PXIe-1065 chassis.
Interoperability with CompactPCI
The design of the NI PXIe-1065 provides you the flexibility to use the
following devices in a single PXI Express chassis:
•
•
•
•
•
PXI Express compatible products
CompactPCI Express compatible 4-Link system controller products
CompactPCI Express compatible Type-2 peripheral products
PXI peripheral products
Standard CompactPCI peripheral products
System Controller Slot
The system controller slot is Slot 1 of the chassis and is a 4-Link
configuration system slot as defined by the CompactPCI Express and
PXI Express specifications. It has three system controller expansion slots
for system controller modules that are wider than one slot. These slots
allow the system controller to expand to the left to prevent the system
controller from using peripheral slots.
The backplane routes a x4 PCI Express link from the system controller
slot to slots 7 and 8, and a x1 PCI Express link to a PCI Express to PCI
Translation Bridge on the backplane. The PCI Express to PCI Translation
Bridge on the backplane provides a 32-bit/33MHz PCI bus to slots 2 to 7.
The second PCI Translation Bridge provides PCI bus to slots 11, 12, 13, 15,
16, 17, and 18 (not to slot 14).
A x4 link goes to the PXI Express switch and the PCI Express connectivity
of slots 9 to 14 is connected through the switch.
The system controller slot also has connectivity to some PXI features such
as: PXI_CLK10, PXI Star, PXI Trigger Bus and PXI Local Bus 6.
NI PXIe-1065 User Manual
1-6
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Getting Started
By default, the system controller will control the power supply with the
PS_ON# signals. A logic low on this line will turn the power supply on.
Note The Inhibit Mode switch on the rear of the chassis must be in the Default position
for the system controller to have control of the power supply. Refer to the Inhibit Mode
Switch section of Chapter 2, Installation and Configuration, for details about the Inhibit
Mode switch.
Hybrid Peripheral Slots
The chassis provides four hybrid peripheral slots as defined by the PXI-5
PXI Express Hardware Specification: slot 7 and slots 11–13. A hybrid
peripheral slot can accept the following peripheral modules:
•
•
•
A PXI Express Peripheral with x4 or x1 PCI Express link to the system
slot or through a switch to the system slot.
A CompactPCI Express Type-2 Peripheral with x4 or x1 PCI Express
link to the system slot or through a switch to the system slot.
A hybrid-compatible PXI Peripheral module that has been modified by
replacing the J2 connector with an XJ4 connector installed in the upper
eight rows of J2. Refer to the PXI Express Specification for details. The
PXI Peripheral communicates through the backplane’s 32-bit PCI bus.
•
A CompactPCI 32-bit peripheral on the backplane’s 32-bit PCI bus.
The hybrid peripheral slots provide full PXI Express functionality and
32-bit PXI functionality except for PXI Local Bus. The hybrid peripheral
slot only connects to PXI Local Bus 6 left and right.
PXI Peripheral Slots
There are nine PXI peripheral slots which will accept PXI or CompactPCI
peripherals: slots 2–6 and slots 15–18. These slots are on the backplane’s
32-bit PCI busses. These slots offer full PXI functionality, but have no
PXI Express features. The 64-bit PCI signals on the P2 connectors are not
connected.
© National Instruments Corporation
1-7
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Getting Started
PXI Express Peripheral Slots
There are three PXI Express peripheral slots: slots 8–10. Slot 8 is directly
connected to the system slot with a x4 PCI Express link. Slots 9 and 10 are
connected to the system slot through a PCI Express switch. PXI Express
peripheral slots can accept the following modules:
•
A PXI Express Peripheral with x4 or x1 PCI Express link to the system
slot or through a switch to the system slot.
•
A CompactPCI Express Type-2 Peripheral with x4 or x1 PCI Express
link to the system slot or through a switch to the system slot.
System Timing Slot
The System Timing Slot is slot 14. The system timing slot will accept the
following peripheral modules:
•
•
•
A PXI Express System Timing Module with x4 or x1 PCI Express link
to the system slot through a PCIe switch.
A PXI Express Peripheral with x4 or x1 PCI Express link to the system
slot through a PCIe switch.
A CompactPCI Express Type-2 Peripheral with x4 or x1 PCI Express
link to the system slot through a PCIe switch.
The system timing slot has 3 dedicated differential pairs (PXIe_DSTAR)
connected from the TP1 and TP2 connectors to the XP3 connector for each
the XP3 connector of the system timing slot as shown in Figure 1-3. The
PXIe_DSTAR pairs can be used for high-speed triggering, synchronization
and clocking. Refer to the PXI Express Specification for details.
The system timing slot also has a single-ended (PXI Star) trigger connected
to every slot. Refer to Figure 1-3 for details.
The system timing slot has a pin (PXI_CLK10_IN) through which a system
timing module may source a 10MHz clock to which the backplane will
phase-lock. Refer to the System Reference Clock section for details.
The system timing slot has a pin (PXIe_SYNC_CTRL) through which a
system timing module can control the PXIe_SYNC100 timing. Refer to the
PXI Express Specification and the PXIe_SYNC_CTRL section of this
chapter for details.
NI PXIe-1065 User Manual
1-8
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Getting Started
PXI STAR 16
PXI STAR 14
PXI STAR 15
PXI STAR 12
PXI STAR 13
PX DSTAR 10
PX STAR 11
PXI STAR 8
PXI STAR 4
PXI STAR 2
PXI STAR 0
PXI STAR 1
PXI STAR 9
PXI STAR 7
PXI STAR 6
PXI STAR 3
PXI STAR 5
8
10
H
H
2
4
11 H 12 H 13
14
15
16
17
18
5
6
7
1
PXIe_DSTAR 1
PXIe_DSTAR 2
PXIe_DSTAR 3
PXIe_DSTAR 4
PXIe_DSTAR 5
PXIe_DSTAR 6
PXI Local Bus
peripheral slot with adjacent peripheral slots to the left and right, as shown
in Figure 1-4.
The backplane routes the full 13-line PXI Local Bus between adjacent PXI
slots (slots 2–6 and 15–18) and PXI Local Bus 6 between all other slots.
Refer to Figure 1-4 for details. The left local bus 6 from slot 1 is not routed
anywhere and the right local bus signals from slot 18 are not routed
anywhere.
© National Instruments Corporation
1-9
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Getting Started
Local bus signals may range from high-speed TTL signals to analog signals
as high as 42 V.
Initialization software uses the configuration information specific to each
adjacent peripheral module to evaluate local bus compatibility.
PXI
PXI
Trigger Bus
Buffer Bridge
Trigger Bus
Buffer Bridge
PXI Trigger Bus Segment 2
PXI Trigger Bus Segment 3
PXI Trigger Bus Segment 1
8
10
H
H
2
4
11 H 12 H 13
14
15
16
17
18
5
6
7
1
Figure 1-4. PXI Trigger Bus and Local Bus Connectivity Diagram
PXI Trigger Bus
All slots on the same PXI bus segment share eight PXI trigger lines. You
can use these trigger lines in a variety of ways. For example, you can use
triggers to synchronize the operation of several different PXI peripheral
modules. In other applications, one module located in the system timing
slot can control carefully timed sequences of operations performed on other
modules in the system. Modules can pass triggers to one another, allowing
precisely timed responses to asynchronous external events the system is
monitoring or controlling.
The PXI trigger lines from adjacent PXI trigger bus segments can be routed
in either direction across the PXI trigger bridges through buffers. This
allows you to send trigger signals to, and receive trigger signals from, every
slot in the chassis. Static trigger routing (user-specified line and directional
NI PXIe-1065 User Manual
1-10
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Getting Started
assignments) can be configured through Measurement & Automation
Explorer (MAX). Dynamic routing of triggers (automatic line assignments)
is supported through certain National Instruments drivers like NI-DAQmx.
Note Although any trigger line may be routed in either direction, it cannot be routed in
more than one direction at a time.
System Reference Clock
The PXIe-1065 chassis supplies the PXI 10 MHz system clock signal
PXIe_CLK100 and PXIe_SYNC100 to the PXI Express slots, hybrid slots,
and system timing slot.
An independent buffer (having a source impedance matched to the
backplane and a skew of less than 1 ns between slots) drives PXI_CLK10
to each peripheral slot. Refer to Figure 1-5 for the routing configuration of
PXI_CLK10. You can use this common reference clock signal to
synchronize multiple modules in a measurement or control system.
An independent buffer drives PXIe_CLK100 to the PXI Express peripheral
slots, hybrid peripheral slots, and system timing slot. Refer to Figure 1-5
for the routing configuration of PXIe_CLK100. These clocks are matched
in skew to less than 100 ps. The differential pair must be terminated on the
so that when there is no peripheral or a peripheral that does not connect to
PXIe_CLK100, there is no clock being driven on the pair to that slot.
An independent buffer drives PXIe_SYNC100 to the PXI Express
peripheral slots, hybrid peripheral slots, and system timing slot. Refer
to Figure 1-5 for the routing configuration of PXIe_SYNC100. The
differential pair must be terminated on the peripheral with LVPECL
termination for the buffer to drive PXIe_SYNC100 so that when there is
no peripheral or a peripheral that does not connect to PXIe_SYNC100,
there is no SYNC100 signal being driven on the pair to that slot.
© National Instruments Corporation
1-11
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Getting Started
10 MHz
REF IN
10 MHz
REF OUT
PXI_CLK10_IN
PXI_CLK10
8
10
H
H
2
4
11 H 12 H 13
14
15
16
17
18
5
6
7
1
Figure 1-5. Distribution of PXI_CLK10, PXIe_CLK100, and PXIe_SYNC100
PXI_CLK10, PXIe_CLK100 and PXIe_SYNC100 have the default timing
relationship described in Figure 1-6.
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
PXIe_CLK100
PXI_CLK10
PXIe_SYNC100
Figure 1-6. System Reference Clock Default Behavior
To synchronize the system to an external clock, you can drive PXI_CLK10
from an external source through the PXI_CLK10_IN pin on the System
Timing Slot, for the pinout. When a 10MHz clock is detected on this pin,
the backplane automatically phase-locks the PXI_CLK10, PXIe_CLK100,
and PXIe_SYNC100 signals to this external clock and distributes these
NI PXIe-1065 User Manual
1-12
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Getting Started
signals to the slots (refer to Figure 1-5 for the distribution of PXI_CLK10,
PXIe_CLK100 and PXIe_SYNC100). Refer to Appendix A,
Specifications, for the specification information for an external clock
rear of the chassis. When a 10MHz clock is detected on this connector, the
backplane automatically phase-locks the PXI_CLK10, PXIe_CLK100, and
PXIe_SYNC100 signals to this external clock and distributes these signals
to the slots (refer to Figure 1-5 for the distribution of PXI_CLK10,
PXIe_CLK100 and PXIe_SYNC100). Refer to Appendix A,
Specifications, for the specification information for an external clock
provided on the 10 MHz REF IN connector on the rear panel of the chassis.
If the 10 MHz clock is present on both the PXI_CLK10_IN pin of the
System Timing Slot and the 10 MHz REF IN connector on the rear of the
chassis, the signal on the System Timing Slot is selected. Refer to Table 1-2
which explains how the 10 MHz clocks are selected by the backplane.
Table 1-2. Backplane External Clock Input Truth Table
System Timing Slot
PXI_CLK10_IN
Rear Chassis Panel
10 MHz REF IN
Backplane PXI_CLK10, PXIe_CLK100
and PXIe_SYNC100
No clock present
No clock present
No clock present
Backplane generates its own clocks
10 MHz clock present
PXI_CLK10, PXIe_CLK100 and
PXIe_SYNC100 all phase-locked to Rear
Chassis Panel—10 MHz REF IN
10 MHz clock present
10 MHz clock present
No clock present
PXI_CLK10, PXIe_CLK100 and
PXIe_SYNC100 all phase-locked to
System Timing Slot— PXI_CLK10_IN
10 MHz clock present
PXIe_SYNC100 all phase-locked to
System Timing Slot—PXI_CLK10__IN
A copy of the backplane’s PXI_CLK10 is exported to the 10 MHz REF
OUT connector on the rear of the chassis. This clock is driven by an
independent buffer. Refer to Appendix A, Specifications, for the
specification information for the 10 MHz REF OUT signal on the rear
panel of the chassis.
© National Instruments Corporation
1-13
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Getting Started
PXIe_SYNC_CTRL
PXIe_SYNC100 is by default a 10 ns pulse synchronous to PXI_CLK10.
The frequency of PXIe_SYNC100 is 10/n MHz, where n is a positive
integer. The default for n is 1, giving PXIe_SYNC100 a 100 ns period.
be set to any positive integer from 1 to 255.
The system timing slot has a control pin for PXIe_SYNC100 called
PXIe_SYNC_CTRL for use when n > 1. Refer to Table B-7, XP3
Connector Pinout for the System Timing Slot, for system timing slot pinout.
Refer to Appendix A, Specifications, for the PXIe_SYNC_CTRL input
specifications.
By default, a high-level detected by the backplane on the
PXIe_SYNC_CTRL pin causes a synchronous restart for the
PXIe_SYNC100 signal. On the next PXI_CLK10 edge the
PXIe_SYNC100 signal will restart. This will allow several chassis to have
their PXIe_SYNC100 in phase with each other. Refer to Figure 1-7 for
timing details with this method.
PXI_CLK10
PXIe_SYNC_CTRL
PXIe_SYNC100
SYNC100 Divider
Restarted Here
Figure 1-7. PXIe_SYNC100 at 3.33 MHz Using PXIe_SYNC_CTRL as Restart
NI PXIe-1065 User Manual
1-14
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
2
Installation and Configuration
This chapter describes how to prepare and operate the NI PXIe-1065
chassis.
Before connecting the chassis to a power source, read this chapter and
the Read Me First: Safety and Radio-Frequency Interference document
included with your kit.
Safety Information
Caution Before undertaking any troubleshooting, maintenance, or exploratory procedure,
carefully read the following caution notices.
This equipment contains voltage hazardous to human life and safety, and
is capable of inflicting personal injury.
•
Chassis Grounding—The chassis requires a connection from the
premise wire safety ground to the chassis ground. The earth safety
ground must be connected during use of this equipment to minimize
shock hazards. Refer to the Connecting Safety Ground section for
instructions on connecting safety ground.
•
Live Circuits—Operating personnel and service personnel must not
remove protective covers when operating or servicing the chassis.
Adjustments and service to internal components must be undertaken
by qualified service technicians. During service of this product,
the mains connector to the premise wiring must be disconnected.
Dangerous voltages may be present under certain conditions;
use extreme caution.
•
Explosive Atmosphere—Do not operate the chassis in conditions
where flammable gases are present. Under such conditions, this
equipment is unsafe and may ignite the gases or gas fumes.
© National Instruments Corporation
2-1
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
Installation and Configuration
•
Part Replacement—Only service this equipment with parts that are
exact replacements, both electrically and mechanically. Contact
National Instruments for replacement part information. Installation of
parts with those that are not direct replacements may cause harm to
personnel operating the chassis. Furthermore, damage or fire may
occur if replacement parts are unsuitable.
•
Modification—Do not modify any part of the chassis from its original
condition. Unsuitable modifications may result in safety hazards.
Chassis Cooling Considerations
The NI PXIe-1065 chassis is designed to operate on a bench or in an
instrument rack. Regardless of the configuration you must provide the
cooling clearances as outlined in the following sections.
Providing Adequate Clearance
intake and exhaust vents are located along the sides of the chassis.
Adequate clearance between the chassis and surrounding equipment or
blockages must be maintained to ensure proper cooling of the chassis
power supply as well as the modules plugged into the chassis. These
clearances are outlined in Figure 2-1. The vent locations for the
NI PXIe-1065 chassis are shown in Figure 2-2. Failure to provide these
clearances may result in thermal-related failures in the chassis or modules.
NI PXIe-1065 User Manual
2-2
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
Installation and Configuration
Dimensions are in inches (millimeters)
1.75
(44.45)
1.75
(44.45)
NI PXIe-1065
H
1
2
3
4
5
6
7
8
9
10
11 H
12 H
13 H
14
15
16
17
18
3.00
(76.20)
Figure 2-1. NI PXIe-1065 Cooling Clearances
© National Instruments Corporation
2-3
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
Installation and Configuration
2
1
3
1
2
Primary Air Exhaust Vent
Primary Air Intake Vent
3
Secondary Air Intake/Exhaust Vents
(both sides)
Figure 2-2. NI PXIe-1065 Vents
Chassis Ambient Temperature Definition
The chassis fan control system uses intake air temperature as the input for
controlling fan speeds when in Auto Fan Speed mode. Because of this, the
chassis ambient temperature is defined as the temperature that exists just
outside of the fan intake vents on the rear of the chassis. Note that this
temperature may be higher than ambient room temperature depending
on the surrounding equipment and/or blockages present. It is the user’s
responsibility to ensure that this ambient temperature does not exceed the
NI PXIe-1065 User Manual
2-4
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
Installation and Configuration
rated ambient temperature as stated in Appendix A, Specifications. If the
temperature exceeds the stated spec the power switch LED will blink green,
chapter.
Setting Fan Speed
The fan-speed selector switch is on the rear panel of the NI PXIe-1065
chassis. Refer to Figure 1-2, Rear View of the NI PXIe-1065 Chassis, to
locate the fan-speed selector switch. Select High for maximum cooling
performance or Auto for improved acoustic performance. When set to
Auto, the fan speed is determined by chassis intake air temperature.
Installing Filler Panels
To maintain proper module cooling performance, install filler panels
(provided with the chassis) in unused or empty slots. Secure with the
captive mounting screws provided.
Installing Slot Blockers
The cooling performance of the chassis can be improved by installing
optional slot blockers. Refer to ni.com for more details.
Rack Mounting
Rack mount applications require the optional rack mount kits available
from National Instruments. Refer to the instructions supplied with the rack
mount kits to install your NI PXIe-1065 chassis in an instrument rack.
Refer to Figure A-3, NI Chassis Rack Mount Kit Components.
Note You may want to remove the feet from the NI PXIe-1065 chassis when rack
mounting. To do so, remove the screws holding the feet in place.
Connecting Safety Ground
Caution The NI PXIe-1065 chassis are designed with a three-position NEMA 5-15 style
plug for the U.S. that connects the ground line to the chassis ground. To minimize shock
hazard, make sure the electrical power outlet you use to power the chassis has an
appropriate earth safety ground.
© National Instruments Corporation
2-5
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
If your power outlet does not have an appropriate ground connection, you
must connect the premise safety ground to the chassis grounding screw
located on the rear panel. Refer to Figure 1-2, Rear View of the
NI PXIe-1065 Chassis, to locate the chassis grounding screw. To connect
the safety ground, complete the following steps:
1. Connect a 16 AWG (1.3 mm) wire to the chassis grounding screw
using a grounding lug. The wire must have green insulation with a
yellow stripe or must be noninsulated (bare).
2. Attach the opposite end of the wire to permanent earth ground using
toothed washers or a toothed lug.
Connecting to Power Source
To completely remove power, you must disconnect the AC power cable.
Attach input power through the rear AC inlet using the appropriate
AC power cable supplied. Refer to Figure 1-2, Rear View of the
NI PXIe-1065 Chassis, to locate the AC inlet.
The Inhibit Mode switch allows you to power on the chassis or place it in
standby mode. Set the Inhibit Mode switch on the back of the chassis to the
Manual position. Observe that all fans become operational and the power
switch LED is a steady green. Switching the Inhibit Mode switch to the
Default position allows the system controller to control the power supply.
Installing a PXI Express System Controller
This section contains general installation instructions for installing a
PXI Express system controller in a NI PXIe-1065 chassis. Refer to your
PXI Express system controller user manual for specific instructions and
warnings. To install a system controller, complete the following steps:
1. Connect the AC power source to the PXI Express chassis before
installing the system controller. The AC power cord grounds the
chassis and protects it from electrical damage while you install the
system controller.
2. Install the system controller into the system controller slot (slot 1,
indicated by the red card guides) by first placing the system controller
PCB into the front of the card guides (top and bottom). Slide the
NI PXIe-1065 User Manual
2-6
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
Installation and Configuration
system controller to the rear of the chassis, making sure that the
injector/ejector handle is pushed down as shown in Figure 2-3.
4
1
3
2
1
2
NI PXI Express System Controller
NI PXIe-1065 Chassis
3
4
Injector/Ejector Handle
System Controller Front Panel Mounting Screws (4x)
Figure 2-3. Installing a PXIe System Controller
3. When you begin to feel resistance, pull up on the injector/ejector
handle to seat the system controller fully into the chassis frame. Secure
the system controller front panel to the chassis using the system
controller front-panel mounting screws.
4. Connect the keyboard, mouse, and monitor to the appropriate
connectors. Connect devices to ports as required by your system
configuration.
5. Power on the chassis. Verify that the system controller boots. If the
system controller does not boot, refer to your system controller user
manual.
© National Instruments Corporation
2-7
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
Installation and Configuration
Figure 2-4 shows a PXI Express system controller installed in the system
controller slot of a NI PXIe-1065 chassis. You can place CompactPCI,
CompactPCI Express, PXI, or PXI Express modules in other slots
depending on the slot type.
1
2
3
1
NI PXIe-1065 Chassis
2
NI PXIe System Controller
3
Injector/Ejector Rail
Figure 2-4. NI PXI Express System Controller Installed in a NI PXIe-1065 Chassis
Caution The NI PXIe-1065 chassis has been designed to accept a variety of peripheral
module types in different slots. To prevent damage to the chassis, ensure that the peripheral
Started, for a description of the various slot types.
NI PXIe-1065 User Manual
2-8
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
Installation and Configuration
This section contains general installation instructions for installing a
peripheral module in a NI PXIe-1065 chassis. Refer to your peripheral
module user manual for specific instructions and warnings. To install a
module, complete the following steps:
1. Connect the AC power source to the PXI Express chassis before
protects it from electrical damage while you install the module.
2. Ensure that the chassis is powered off.
3. Install a module into a chassis slot by first placing the module card
PCB into the front of the card guides (top and bottom), as shown in
Figure 2-5. Slide the module to the rear of the chassis, making sure that
the injector/ejector handle is pushed down as shown in Figure 2-5.
4. When you begin to feel resistance, push up on the injector/ejector
handle to fully seat the module into the chassis frame. Secure the
module front panel to the chassis using the module front-panel
mounting screws.
3
2
NI
PXIe-106
5
1
6
4
5
1
2
3
Peripheral Module Front Panel Mounting Screws (2x)
NI PXI Express System Controller
NI PXIe-1065 Chassis
4
5
6
Injector/Ejector Rail
Injector/Ejector Handle
PXI Peripheral Module
Figure 2-5. Installing PXI, PXI Express, or CompactPCI Peripheral Modules
© National Instruments Corporation
2-9
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
Installation and Configuration
Power Inhibit Switch LED Indicator
The chassis power inhibit switch has an integrated LED. This LED
indicates one of four different conditions:
•
•
•
•
If the inhibit switch LED is steady green (not flashing), the chassis is
powered on and operating normally.
If the inhibit switch LED is flashing green, the air-intake temperature
has exceeded the chassis operating range.
If the inhibit switch LED is flashing red, the power supply outputs are
not within voltage regulation requirements.
If the inhibit switch LED is steady red, the system fans or power supply
fan has failed. The remaining fans will automatically be driven high.
Note If two system fans or both of the power supply fans fail the chassis will shut down
automatically, preventing the chassis and modules from damage due to overheating.
Remote Voltage Monitoring and Control
The NI PXIe-1065 chassis supports remote voltage monitoring and
inhibiting through a female 9-pin D-SUB (DB-9) connector located on
the rear panel. Table 2-1 shows the pinout of the 9-pin D-SUB (DB-9)
connector.
Table 2-1. Remote Inhibit and Voltage Monitoring Connector Pinout
DB-9 Pin
Signal
Logic Ground
+5 VDC
1
2
3
4
5
6
7
Reserved
+3.3 VDC
Inhibit (Active Low)
+12 VDC
Reserved
NI PXIe-1065 User Manual
2-10
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
Installation and Configuration
Table 2-1. Remote Inhibit and Voltage Monitoring Connector Pinout (Continued)
DB-9 Pin
Signal
–12 VDC
8
9
Logic Ground
6
7
8
9
1
2
3
4
5
connector, be careful not to short the probe leads together. Doing so could damage the
power supply.
You can use a digital voltmeter to ensure all voltage levels in the
NI PXIe-1065 chassis are within the allowable limits. Referring to
Table 2-2, connect one lead of the voltmeter to a supply pin on the remote
voltage monitoring connector (9-pin D-SUB) on the rear panel. Refer to
Table 2-1 for a pinout diagram of the remote voltage monitoring connector.
Connect the reference lead of the voltmeter to one of the ground pins.
Compare each voltage reading to the values listed in Table 2-2.
Note Use the rear-panel 9-pin D-SUB connector to check voltages only. Do not use the
connector to supply power to external devices.
Table 2-2. Power Supply Voltages at Voltage Monitoring Connector (DB-9)
Pin
2
Supply
+5 V
Acceptable Voltage Range
4.75 to 5.25 V
3.135 to 3.465 V
11.4 to 12.6 V
–12.6 to –11.4 V
0 V
4
+3.3 V
6
+12 V
8
–12 V
1, 9
Logic Ground
If the voltages fall within the specified ranges, the chassis complies with the
CompactPCI voltage-limit specifications.
© National Instruments Corporation
2-11
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
Installation and Configuration
Inhibit Mode Switch
On the rear panel of the chassis there is an Inhibit Mode switch. Refer to
Figure 1-2, Rear View of the NI PXIe-1065 Chassis, for the location. The
Inhibit Mode switch is recessed to prevent it from accidentally being
switched.
The Inhibit Mode switch should be in the Default position when normal
power inhibit switch functionality is desired. If the user needs to power on
a chassis without a system controller installed the switch should be in the
Manual position.
When the Inhibit Mode switch is set to the Manual position, the power
supplies are enabled, and you can use the Inhibit signal (active low) on
pin 5 of the Remote Inhibit and Voltage Monitoring connector to power off
the chassis. To remotely power off the chassis, connect the Inhibit pin
(pin 5) to a Logic Ground pin (pin 1 or 9). As long as this connection exists,
the chassis will remain off (standby); when you remove this connection, the
chassis turns on.
Note For the Remote Inhibit signal to control the On/Off (standby) state of the chassis,
the Inhibit Mode switch must be in the Manual position.
PXI_CLK10 Rear Connectors
There are two BNC connectors on the rear of the NI PXIe-1065 chassis for
PXI_CLK10. The connectors are labeled IN and OUT. You can use them
for supplying the backplane with PXI_CLK10 or routing the backplane’s
PXI_CLK10 to another chassis. Refer to the System Reference Clock
section of Chapter 1, Getting Started, for details about these signals.
PXI Express System Configuration with MAX
The PXI Platform Services software included with your chassis
automatically identifies your PXI Express system components to generate
a pxiesys.ini file. You can configure your entire PXI system and
identify PXI-1 chassis through Measurement & Automation Explorer
(MAX), included with your system controller. MAX creates the
parameters. MAX also provides an interface to route and reserve triggers
so dynamic routing, through drivers such as DAQmx, avoids
NI PXIe-1065 User Manual
2-12
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
Installation and Configuration
double-driving and potentially damaging trigger lines. For more
information about routing and reserving PXI triggers, refer to
KnowledgeBase 3TJDOND8 at ni.com/support.
The configuration steps for single or multiple-chassis systems are the same.
Figure 2-6. Multichassis Configuration in MAX
PXI-1 System Configuration
1. Launch MAX.
2. In the Configuration tree, click the Devices and Interfaces branch to
expand it.
3. If the PXI system controller has not yet been configured, it is labeled
PXI System (Unidentified). Right-click this entry to display the
pop-up menu, then select the appropriate system controller model from
the Identify As submenu.
© National Instruments Corporation
2-13
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
Installation and Configuration
4. Click the PXI system controller. The chassis (or multiple chassis, in a
multichassis configuration) is listed below it. Identify each chassis by
right-clicking its entry, then selecting the appropriate chassis model
through the Identify As submenu. Further expanding the PXI System
branch shows all devices in the system that can be recognized by
NI-VISA. When your system controller and all your chassis are
identified, the required pxisys.ini file is complete.
The PXI specification allows for many combinations of PXI chassis and
system modules. To assist system integrators, the manufacturers of
PXI chassis and system modules must document the capabilities of their
products. PXI Express devices must provide a driver and .ini file for
identification. These files are provided as part of the PXI Platform Services
software included with your system controller. The minimum
documentation requirements for PXI-1 are contained in .ini files, which
consist of ASCII text. System integrators, configuration utilities, and
device drivers can use these .ini files.
The capability documentation for a PXI-1 chassis is contained in a
chassis.ini file provided by the chassis manufacturer. The information
in this file is combined with information about the system controller to
create a single PXI-1 system initialization file called pxisys.ini
(PXI System Initialization). The NI system controller uses MAX to
generate the pxisys.ini file from the chassis.ini file.
Device drivers and other utility software read the pxiesys.ini and
pxisys.ini file to obtain system information. For detailed information
Trigger Configuration in MAX
Each chassis has one or more trigger buses, each with eight lines
numbered 0 through 7 that can be reserved and routed statically or
dynamically. Static reservation pre-allocates a trigger line to prevent its
configuration by a user program. Dynamic reservation/routing/deallocation
is on the fly within a user program based upon National Instruments APIs
such as NI-DAQmx. Static reservation of trigger lines can be implemented
by the user in MAX through the Triggers tab. Reserved trigger lines will
not be used by PXI modules dynamically configured by programs such as
NI-DAQmx. This prevents the instruments from double-driving the trigger
lines, possibly damaging devices in the chassis. In the default
configuration, trigger lines on each bus are independent. For example,
if trigger line 3 is asserted on trigger bus 0, by default it will not be
automatically asserted on any other trigger bus.
NI PXIe-1065 User Manual
2-14
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
Installation and Configuration
Complete the following steps to reserve these trigger lines in MAX.
1. In the Configuration tree, click on the PXI chassis branch you want to
configure.
2. Then, in the right-hand pane, toward the bottom, click on the
Triggers tab.
3. Select which trigger lines you would like to statically reserve.
4. Click the Apply button.
PXI Trigger Bus Routing
Some National Instruments chassis, such as the PXI-1065 and the
PXI-1044/1045, have the capability to route triggers from one bus to others
within the same chassis using the Trigger Routing tab in MAX, as shown
in Figure 2-6.
Note Selecting any non-disabled routing automatically reserves the line in all trigger
buses being routed to. If you are using NI-DAQmx, it will reserve and route trigger lines
for you, so you won’t have to route trigger lines manually.
Complete the following steps to configure trigger routings in MAX.
1. In the Configuration tree, select the chassis in which you want to
route trigger lines.
2. In the right-hand pane, select the Trigger Routing tab near the bottom.
3. For each trigger line, select Route Right, Route Outward From
Middle, or Route Left to route triggers on that line in the described
direction, or select Disabled for the default behavior with no manual
routing.
4. Click the Apply button.
© National Instruments Corporation
2-15
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
Installation and Configuration
Using System Configuration and Initialization Files
The PXI Express specification allows many combinations of PXI Express
chassis and system modules. To assist system integrators, the
manufacturers of PXI Express chassis and system modules must document
the capabilities of their products. The minimum documentation
requirements are contained in .ini files, which consist of ASCII text.
System integrators, configuration utilities, and device drivers can use these
.ini files.
The capability documentation for the NI PXIe-1065 chassis is contained in
the chassis.ini file on the software media that comes with the chassis.
The information in this file is combined with information about the system
controller to create a single system initialization file called pxisys.ini
(PXI System Initialization). The system controller manufacturer either
provides a pxisys.ini file for the particular chassis model that contains
the system controller or provides a utility that can read an arbitrary
chassis.ini file and generate the corresponding pxisys.ini file.
System controllers from NI provide the pxisys.ini file for the
NI PXIe-1065 chassis, so you should not need to use the chassis.ini
file. Refer to the documentation provided with the system controller or
to ni.com/support for more information on pxisys.ini and
chassis.ini files.
Device drivers and other utility software read the pxisys.ini file to
obtain system information. The device drivers should have no need to
directly read the chassis.ini file. For detailed information regarding
initialization files, refer to the PXI Express specification at
NI PXIe-1065 User Manual
2-16
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Maintenance
This chapter describes basic maintenance procedures you can perform on
the NI PXIe-1065 chassis.
Caution Disconnect the power cable prior to servicing a NI PXIe-1065 chassis.
Service Interval
Clean dust from the chassis exterior (and interior) as needed, based on the
operating environment. Periodic cleaning increases reliability.
Preparation
The information in this section is designed for use by qualified service
personnel. Read the Read Me First: Safety and Radio-Frequency
Interference document included with your kit before attempting any
procedures in this chapter.
Caution Many components within the chassis are susceptible to static discharge damage.
Service the chassis only in a static-free environment. Observe standard handling
precautions for static-sensitive devices while servicing the chassis. Always wear a
grounded wrist strap or equivalent while servicing the chassis.
Cleaning
Cleaning procedures consist of exterior and interior cleaning of the chassis.
Refer to your module user documentation for information on cleaning the
individual CompactPCI or PXI Express modules.
Caution Always disconnect the AC power cable before cleaning or servicing the chassis.
Interior Cleaning
Use a dry, low-velocity stream of air to clean the interior of the chassis.
Use a soft-bristle brush for cleaning around components.
© National Instruments Corporation
3-1
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3
Maintenance
Exterior Cleaning
Clean the exterior surfaces of the chassis with a dry lint-free cloth or a
soft-bristle brush. If any dirt remains, wipe with a cloth moistened in a mild
soap solution. Remove any soap residue by wiping with a cloth moistened
with clear water. Do not use abrasive compounds on any part of the chassis.
Caution Avoid getting moisture inside the chassis during exterior cleaning, especially
through the top vents. Use just enough moisture to dampen the cloth.
Do not wash the front- or rear-panel connectors or switches. Cover these components while
cleaning the chassis.
Do not use harsh chemical cleaning agents; they may damage the chassis. Avoid chemicals
that contain benzene, toluene, xylene, acetone, or similar solvents.
Resetting the AC Mains Circuit Breaker
If the NI PXIe-1065 chassis is connected to an AC source and encounters
an over-current condition, the circuit breaker on the rear panel will trip to
prevent damage to the chassis. Complete the following steps to reset the
circuit breaker.
1. Turn off the chassis.
2. Disconnect the AC power cable.
3. Depress the circuit breaker to reset it.
4. Reconnect the AC power cable.
5. Turn on the chassis.
1. Turn off the chassis.
2. Disconnect the AC power cable.
3. Remove all modules from the chassis.
4. Complete the procedure described in the Connecting to Power Source
section of Chapter 2, Installation and Configuration. If the power
switch LED is not a steady green, contact National Instruments.
5. Verify that the NI PXIe-1065 chassis can meet the power requirements
of your CompactPCI or PXI Express modules. Overloading the chassis
can cause the breaker to trip. Refer to Appendix A, Specifications.
NI PXIe-1065 User Manual
3-2
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3
Maintenance
6. The over-current condition that caused the circuit breaker to trip
may be due to a faulty CompactPCI or PXI Express module. Refer to
the documentation supplied with the modules for troubleshooting
information.
Replacing the Modular Power Supply
This section describes how to remove, configure, and install the AC
power supply shuttle in the NI PXIe-1065 chassis.
Cautions Disconnect the power cable prior to replacing the power supply.
Do not attempt to use a power supply shuttle from another chassis such as the
NI PXI-1044/1045. Doing so may damage your chassis and the power supply shuttle.
Before connecting the power supply shuttle to a power source, read this
section and the Read Me First: Safety and Radio-Frequency Interference
document included with the kit.
Removal
The NI PXIe-1065 AC power supply is a replacement part for the
NI PXIe-1065 AC chassis. Before attempting to replace the power supply
shuttle, verify that there is adequate clearance behind the chassis.
Disconnect the power cable from the power supply shuttle on the back of
the chassis. Identify the ten mounting screws for the NI PXIe-1065 that
attach the power supply shuttle to the chassis. Refer to Figure 1-2, Rear
View of the NI PXIe-1065 Chassis, for the screw locations. Using a Phillips
screwdriver, remove the screws. Pull on the two rear handles of the power
supply shuttle to remove it from the back of the chassis.
Installation
Ensure that there is no visible damage to the new power supply shuttle.
Verify that the housing and connector on the new power supply shuttle
have no foreign material inside. Remove the protective cap on the
PXI_CLK10 connector. Install the new power supply shuttle into the
opening on the rear of the chassis. Replace and tighten the ten screws with
a Phillips screwdriver.
© National Instruments Corporation
3-3
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3
Maintenance
Configuration
The fan-speed selector switch is on the rear panel of the power supply
shuttle. Refer to Figure 1-2, Rear View of the NI PXIe-1065 Chassis,
Mode switch to the Default position.
Connecting Safety Ground
and Configuration.
Connecting to Power Source
Refer to the Connecting to Power Source section of Chapter 2, Installation
and Configuration.
NI PXIe-1065 User Manual
3-4
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
A
Specifications
This appendix contains specifications for the NI PXIe-1065 chassis.
Caution Specifications are subject to change without notice.
Electrical
AC Input
Input voltage range................................. 100 to 240 VAC
Operating voltage range1........................ 90 to 264 VAC
Input frequency ...................................... 50/60 Hz
Operating frequency range1 ................... 47 to 63 Hz
Input current rating................................. 10–5 A
Over-current protection.......................... 12 A circuit breaker
Line regulation
3.3 V................................................ < 0.2%
5 V................................................... < 0.1%
12 V .............................................. < 0.1%
Efficiency............................................... 70% typical
Power disconnect ....................................The AC power cable provides
main power disconnect. The
front-panel power switch causes
the internal chassis power supply
to provide DC power to the
CompactPCI/PXI Express
backplane. You also can use the
rear-panel D-SUB 9-pin connector
and power mode switch to control
the internal chassis power supply.
1
The operating range is guaranteed by design.
© National Instruments Corporation
A-1
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A
Specifications
DC Output
DC current capacity (IMP
)
Voltage
+3.3 V
Maximum Current
61 A
56 A
45 A
4 A
+5 V
+12 V
–12 V
5 VAUX
1.5 A
Note Maximum combined +3.3 V, +5 V, and +12 V power is 699 W.
Maximum total power is 701.5 W.
The maximum power dissipated in the system slot should not exceed 140 W.
Backplane pin current capacity
Slot
+5 V
9 A
V (I/O) +3.3 V
+12 V
11 A
2 A
–12 V
0 A
5 VAUX
1 A
System Controller Slot
System Timing Slot
0 A
0 A
5 A
9 A
3 A
6 A
0 A
6 A
0 A
1 A
Hybrid Peripheral Slot with
PXI-1 Peripheral
1 A
1 A
0 A
Hybrid Peripheral Slot with
PXI-5 Peripheral
0 A
6 A
0 A
3 A
6 A
3 A
1 A
0 A
1 A
1 A
0 A
PXI-1 Peripheral Slot
11 A
Load regulation
Voltage
Load Regulation
+3.3 V
+12 V
+5 V
<5%
<5%
<5%
<5%
–12 V
NI PXIe-1065 User Manual
A-2
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A
Specifications
Maximum ripple and noise (20 MHz bandwidth)
Voltage
+3.3 V
+12 V
+5 V
Maximum Ripple and Noise
50 mVpp
120 mVpp
50 mVpp
–12 V
120 mVpp
Over-current protection.......................... All outputs protected from short
circuit and overload with
automatic recovery
Over-voltage protection
3.3 V and 5 V.................................. Clamped at 20 to 30% above
nominal output voltage
Power supply shuttle MTTR.................. Replacement in under 5 minutes
Chassis Cooling
Module cooling system
NI PXIe-1065.................................. Forced air circulation
(positive pressurization) through
three 165 cfm fans with
High/Auto speed selector
Slot airflow direction ............................. Bottom of module to top of
module
Module cooling intake ........................... Bottom rear of chassis
Module cooling exhaust......................... Along both sides and top of
chassis
Power supply cooling system................. Forced air circulation through
two integrated fans
Power supply cooling intake.................. Right side of chassis
Power supply cooling exhaust................ Left side of chassis
© National Instruments Corporation
A-3
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A
Specifications
Environmental
Maximum altitude...................................2,000 m (800 mbar)
(at 25 °C ambient)
Pollution Degree.....................................2
For indoor use only.
Operating Environment
Ambient temperature range ....................0 to 55 °C
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3
low temperature limit and
MIL-PRF-28800F Class 2
high temperature limit.)
Relative humidity range..........................10 to 90%, noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Storage Environment
Ambient temperature range ....................–40 to 71 °C
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3 limits.)
Relative humidity range..........................5 to 95%, noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Shock and Vibration
Operational shock...................................30 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27. Meets
MIL-PRF-28800F Class 2 limits.)
Random Vibration ..................................5 to 500 Hz, 0.3 grms
NI PXIe-1065 User Manual
A-4
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A
Specifications
Acoustic Emissions
Sound Pressure Level (at Operator Position)
(Tested in accordance with ISO 7779. Meets MIL-PRF-28800F
requirements.)
Auto fan (up to ~30 °C ambient) ........... 45.0 dBA
High fan.................................................. 63.3 dBA
Sound Power
Auto fan (up to ~30 °C ambient) ........... 55.5 dBA
High fan.................................................. 76.2 dBA
Note Specifications are subject to change without notice.
Safety
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control,
•
•
IEC 61010-1, EN 61010-1
UL 61010-1, CSA 61010-1
Note For UL and other safety certifications, refer to the product label or the Online
Product Certification section.
Electromagnetic Compatibility
This product is designed to meet the requirements of the following
standards of EMC for electrical equipment for measurement, control,
and laboratory use:
•
•
•
•
EN 61326 (IEC 61326): Class A emissions; Basic immunity
EN 55011 (CISPR 11): Group 1, Class A emissions
AS/NZS CISPR 11: Group 1, Class A emissions
FCC 47 CFR Part 15B: Class A emissions
ICES-001: Class A emissions
Note For the standards applied to assess the EMC of this product, refer to the Online
Product Certification section.
© National Instruments Corporation
A-5
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A
Specifications
Note For EMC compliance, operate this device with shielded cabling.
CE Compliance
This product meets the essential requirements of applicable European
Directives as follows:
•
•
2006/95/EC; Low-Voltage Directive (safety)
2004/108/EC; Electromagnetic Compatibility Directive (EMC)
Online Product Certification
Refer to the product Declaration of Conformity (DoC) for additional
regulatory compliance information. To obtain product certifications and the
DoC for this product, visit ni.com/certification, search by model
number or product line, and click the appropriate link in the Certification
column.
Environmental Management
National Instruments is committed to designing and manufacturing
products in an environmentally responsible manner. NI recognizes that
eliminating certain hazardous substances from our products is beneficial
not only to the environment but also to NI customers.
For additional environmental information, refer to the NI and the
Environment Web page at ni.com/environment. This page contains the
environmental regulations and directives with which NI complies, as well
as other environmental information not included in this document.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling
center. For more information about WEEE recycling centers and National Instruments
WEEE initiatives, visit ni.com/environment/weee.htm.
⬉ᄤֵᙃѻક∵ᶧ
ࠊ ㅵ⧚ࡲ ⊩ ˄Ё ˅
RoHS
Ёᅶ᠋
݇Ѣ
ヺড়Ё⬉ᄤֵᙃѻકЁ䰤
ࠊ Փ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ DŽ
National Instruments
National Instruments
(RoHS)
Ё
ড়㾘ᗻֵᙃˈ䇋ⱏᔩ ni.com/environment/rohs_chinaDŽ
RoHS
ni.com/environment/rohs_china
(For information about China RoHS compliance, go to
.)
NI PXIe-1065 User Manual
A-6
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A
Specifications
Backplane
Size......................................................... 3U-sized; one system slot
(with three system expansion
slots) and 17 peripheral slots.
Compliant with IEEE 1101.10
mechanical packaging.
PXI Express Specification
compliant.
Accepts both PXI Express and
CompactPCI (PICMG 2.0 R 3.0)
3U modules.
Backplane bare-board material .............. UL 94 V-0 Recognized
Backplane connectors ............................ Conforms to IEC 917 and
IEC 1076-4-101, and are
UL 94 V-0 rated
System Synchronization Clocks (PXI_CLK10, PXIe_CLK100,
PXIe_SYNC100)
10 MHz System Reference Clock: PXI_CLK10
Maximum slot-to-slot skew ................... 1 ns
Accuracy ................................................ 25 ppm max. (guaranteed over
the operating temperature range)
Maximum jitter ...................................... 5 ps RMS phase-jitter
(10 Hz–1 MHz range)
Duty-factor............................................. 45%–55%
Unloaded signal swing........................... 3.3 V 0.3 V
Note For other specifications refer to the PXI-1 Hardware Specification.
100 MHz System Reference Clock: PXIe_CLK100 and
PXIe_SYNC100
Maximum slot-to-slot skew ................... 100 ps
Accuracy ................................................ 25 ppm max. (guaranteed over
the operating temperature range)
© National Instruments Corporation
A-7
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A
Specifications
Maximum jitter.......................................3 ps RMS phase-jitter
(10 Hz–12 kHz range)
2 ps RMS phase-jitter
(12 kHz–20 MHz range)
Duty-factor for PXIe_CLK100...............45%–55%
Absolute single-ended voltage swing
(When each line in the differential pair
has 50 W termination to 1.30 V
or Thévenin equivalent)..........................400–1000 mV
Note For other specifications refer to the PXI-5 PXI Express Hardware Specification.
External 10 MHz Reference Out (BNC on rear panel of
chassis)
Accuracy................................................. 25 ppm max. (guaranteed over
the operating temperature range)
Maximum jitter.......................................5 ps RMS phase-jitter
(10 Hz–1 MHz range)
Output amplitude ....................................1 VPP 20% square-wave
into 50 Ω
2 VPP unloaded
Output impedance...................................50 Ω 5 Ω
External Clock Source
Frequency ...............................................10 MHz 100 PPM
Input amplitude
Rear panel BNC...............................200 mVPP to 5 VPP square-wave
or sine-wave
System timing slot
PXI_CLK10_IN ..............................5 V or 3.3 V TTL signal
Rear panel BNC input impedance ..........50 Ω 5 Ω
Maximum jitter introduced
by backplane...........................................1 ps RMS phase-jitter
(10 Hz–1 MHz range)
NI PXIe-1065 User Manual
A-8
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A
Specifications
PXIe_SYNC_CTRL
VIH.......................................................... 2.0–5.5 V
VIL .......................................................... 0–0.8 V
Maximum slot-to-slot skew ................... 250 ps
Backplane characteristic impedance ...... 65 Ω 10%
Note For PXI slot to PXI Star mapping refer to the System Timing Slot section of
Chapter 1, Getting Started.
For other specifications refer to the PXI-1 Hardware Specification.
PXI Differential Star Triggers (PXIe-DSTARA,
PXIe-DSTARB, PXIe-DSTARC)
Maximum slot-to-slot skew ................... 150 ps
Maximum differential skew................... 25 ps
Backplane differential impedance.......... 100 Ω 10%
Note For PXIe slot to PXI_DSTAR mapping refer to the System Timing Slot section
of Chapter 1, Getting Started.
For other specifications, the NI PXIe-1065 complies with the PXI-5 PXI Express
Hardware Specification.
Mechanical
Overall dimensions
Standard chassis
Height ...................................... 6.97 in. (177.1 mm)
Width ....................................... 18.30 in. (464.8 mm)
Depth ....................................... 18.40 in. (467.4 mm)
feet extended on table top, height is increased approximately 2.08 in. (52.8 mm) in front
and 0.583 in. (14.8 mm) in rear.
© National Instruments Corporation
A-9
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A
Specifications
Weight ....................................................12.8 kg (28.2 lb)
Chassis materials ....................................Sheet Aluminum (5052-H32,
3003-H14, and 6061-T6),
Extruded Aluminum (6060-T6),
and Cold Rolled Steel, PC-ABS,
Santoprene, Nylon
Finish ......................................................Conductive Clear Iridite
on Aluminum
Electroplated Nickel
on Cold Rolled Steel
Polyurethane Enamel
NI PXIe-1065 User Manual
A-10
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A
Specifications
Figures A-1 and A-2 show the NI PXIe-1065 chassis dimensions. The
holes shown are for the installation of the optional rack mount kits. You can
install those kits on the front or rear of the chassis, depending on which end
of the chassis you want to face toward the front of the instrument cabinet.
Notice that the front and rear chassis mounting holes (size M4) are
symmetrical.
Dimensions are in inches (millimeters)
.39
(9.9)
17.54 (445.6)
NI PXIe-1065
6.97
(177.1)
H
1
2
3
4
5
6
7
8
9
10
11 H
12 H
13 H
14
15
16
17
18
0.57
(14.5)
1.14
(29.1)
1.82
(46.3)
1.82
(46.3)
1.37
(34.8)
1.58
(40.1)
10.21 (259.1)
Front of
PXI Card
1.84
(46.8)
3.54
(90.0)
0.30 (7.25)
2.12
(53.8)
17.11 (434.6)
3.19
(81.1)
Figure A-1. NI PXIe-1065 Chassis Dimensions (Front and Side)
© National Instruments Corporation
A-11
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A
Specifications
Figure A-3 shows the chassis rack mount kit components.
2
NI
PXI
e-106
5
3
1
1
Front Rack Mount Kit
2
NI Chassis
3
Optional Rear Rack Mount Kit
Figure A-3. NI Chassis Rack Mount Kit Components
Note The chassis shown in Figure A-3 is representative of the NI PXI-1044/1045 and
NI PXIe-1065 product line.
© National Instruments Corporation
A-13
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
B
Pinouts
This appendix describes the connector pinouts for the NI PXIe-1065
chassis backplane.
Table B-1 shows the XP1 connector pinout for the System Controller slot.
Table B-2 shows the XP2 Connector Pinout for the System Controller slot.
Table B-3 shows the XP3 Connector Pinout for the System Controller slot.
Table B-4 shows the XP4 Connector Pinout for the System Controller slot.
Table B-5 shows the TP1 Connector Pinout for the System Controller slot.
Table B-6 shows the TP2 Connector Pinout for the System Timing slot.
Table B-7 shows the XP3 Connector Pinout for the System Timing slot.
Table B-8 shows the XP4 Connector Pinout for the System Timing slot.
Table B-9 shows the P1 connector pinout for the peripheral slots.
Table B-10 shows the P2 connector pinout for the peripheral slots.
Table B-11 shows the P1 connector pinout for the Hybrid peripheral slots.
Table B-12 shows the XP3 Connector Pinout for the Hybrid
peripheral slots.
Table B-13 shows the XP4 Connector Pinout for the Hybrid
peripheral slots.
For more detailed information, refer to the PXI-5 PXI Express Hardware
Specification, Revision 2.0. Contact the PXI Systems Alliance for a copy
of the specification.
© National Instruments Corporation
B-1
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B
Pinouts
System Controller Slot Pinouts
Table B-1. XP1 Connector Pinout for the System Controller Slot
Pins
A
Signals
GND
12V
B
C
12V
D
GND
5V
E
F
3.3V
GND
G
Table B-2. XP2 Connector Pinout for the System Controller Slot
Pin
A
B
ab
C
D
cd
E
F
ef
1
2
3
4
5
6
7
8
9
3PETp1
3PETn1
GND
3PERp1
3PERn1
GND
3PETp2
3PETn2
3PERn2
4PETn1
4PERn1
RSV
GND
3PETp3
4PETp0
4PETp2
4PETp3
RSV
3PETn3
4PETn0
4PETn2
4PETn3
RSV
GND
GND
GND
GND
GND
GND
GND
GND
GND
3PERp3
4PERp0
4PERp2
4PERp3
RSV
3PERn3
4PERn0
4PERn2
4PERn3
RSV
GND
GND
GND
GND
GND
GND
GND
GND
GND
3PERp2
4PETp1
4PERp1
RSV
GND
GND
GND
GND
GND
GND
GND
GND
GND
RSV
RSV
RSV
RSV
RSV
RSV
RSV
RSV
RSV
RSV
RSV
RSV
RSV
RSV
RSV
RSV
RSV
RSV
RSV
RSV
10
RSV
RSV
RSV
RSV
RSV
RSV
Table B-3. XP3 Connector Pinout for the System Controller Slot
Pin
A
B
ab
C
D
cd
E
F
ef
1
2
3
4
5
6
RSV
RSV
RSV
GND
RSV
RSV
GND
RSV
RSV
GND
GND
GND
GND
GND
GND
RSV
GND
GND
GND
GND
GND
PWR_OK
4RefClk+
3RefClk+
1PERp0
PS_ON#
4RefClk–
3RefClk–
1PERn0
1PERn2
GND
GND
GND
GND
GND
LINKCAP
2RefClk+
1RefClk+
1PETp1
PWRBTN#
2RefClk–
1RefClk–
1PETn1
1PERn1
SMBDAT
RSV
SMBCLK
PERST#
1PETn0
1PETn2
1PETp0
1PETp2
1PERp2
1PERp1
NI PXIe-1065 User Manual
B-2
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B
Pinouts
Table B-3. XP3 Connector Pinout for the System Controller Slot (Continued)
Pin
A
B
ab
C
D
cd
E
F
ef
7
8
9
1PETp3
1PETn3
GND
1PERp3
1PERn3
GND
2PETp0
2PETn0
GND
2PETp1
2PETp2
3PETp0
2PETn1
2PETn2
3PETn0
GND
GND
GND
2PERp1
2PERp2
3PERp0
2PERn1
2PERn2
3PERn0
GND
GND
GND
2PERp0
2PETp3
2PERp3
2PERn0
2PETn3
2PERn3
GND
GND
GND
10
Table B-4. XP4 Connector Pinout for the System Controller Slot
Pin
Z
GND
GND
GND
GND
GND
GND
GND
GND
A
B
C
D
E
F
1
2
3
4
5
6
7
8
GA4
5Vaux
RSV
RSV
GA3
GND
RSV
RSV
GA2
GA1
GA0
GND
GND
GND
GND
GND
GND
GND
GND
SYSEN#
RSV
WAKE#
RSV
ALERT#
RSV
RSV
RSV
RSV
PXI_TRIG3
PXI_TRIG2
PXI_TRIG1
RSV
PXI_TRIG4
GND
PXI_TRIG5
RSV
GND
PXI_TRIG6
PXI_CLK10
PXI_TRIG7
PXI_LBR6
PXI_STAR
GND
PXI_TRIG0
GND
RSV
RSV
RSV
System Timing Slot Pinouts
Table B-5. TP1 Connector Pinout for the System Timing Slot
Pin
A
B
ab
C
D
cd
E
F
ef
1
PXIe_DSTARA3+
PXIe_DSTARC4+
PXIe_DSTARB4+
PXIe_DSTARA4+
PXIe_DSTARC5+
PXIe_DSTARB5+
PXIe_DSTARA5+
PXIe_DSTARC6+
PXIe_DSTARB6+
PXIe_DSTARA6+
PXIe_DSTARA3–
PXIe_DSTARC4–
PXIe_DSTARB4–
PXIe_DSTARA4–
PXIe_DSTARC5–
PXIe_DSTARB5–
PXIe_DSTARA5–
PXIe_DSTARC6–
PXIe_DSTARB6–
PXIe_DSTARA6–
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
NC
NC
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
2
PXI_STAR12
PXI_STAR13
3
NC
NC
4
NC
NC
5
PXI_STAR14
PXI_STAR15
6
NC
NC
NC
RSV
NC
NC
7
NC
8
PXI_STAR16
9
NC
NC
10
© National Instruments Corporation
B-3
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B
Pinouts
Table B-6. TP2 Connector Pinout for the System Timing Slot
Pin
A
B
ab
C
PXIe_DSTARC8+
NC
D
PXIe_DSTARC8–
NC
cd
E
F
ef
1
NC
NC
NC
NC
NC
NC
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
PXIe_DSTARB8+
PXIe_DSTARB8–
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
2
PXIe_DSTARA8+
PXIe_DSTARA8–
3
PXIe_DSTARC1+
PXI_STAR0
PXI_STAR2
PXI_STAR4
PXI_STAR6
PXI_STAR8
PXI_STAR10
NC
PXIe_DSTARC1–
PXI_STAR1
PXI_STAR3
PXI_STAR5
PXI_STAR7
PXI_STAR9
PXI_STAR11
NC
NC
NC
4
PXIe_DSTARB1+
PXIe_DSTARA1+
PXIe_DSTARC2+
PXIe_DSTARB2+
PXIe_DSTARA2+
PXIe_DSTARC3+
PXIe_DSTARB3+
PXIe_DSTARB1–
PXIe_DSTARA1–
PXIe_DSTARC2–
PXIe_DSTARB2–
PXIe_DSTARA2–
PXIe_DSTARC3–
PXIe_DSTARB3–
NC
NC
5
NC
NC
6
NC
NC
7
NC
NC
8
PXIe_DSTARC11+
PXIe_DSTARA11+
PXIe_DSTARB11+
PXIe_DSTARC11–
PXIe_DSTARA11–
PXIe_DSTARB11–
9
10
Table B-7. XP3 Connector Pinout for the System Timing Slot
Pin
A
PXIe_CLK100+
PRSNT#
SMBDAT
MPWRGD*
1PETp0
B
PXIe_CLK100–
PWREN#
SMBCLK
PERST#
1PETn0
ab
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
C
PXIe_SYNC100+
PXIe_DSTARB+
RSV
D
PXIe_SYNC100–
PXIe_DSTARB–
RSV
cd
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
E
PXIe_DSTARC+
PXIe_DSTARA+
RSV
F
PXIe_DSTARC–
PXIe_DSTARA–
RSV
ef
1
GND
2
GND
GND
GND
GND
GND
GND
GND
GND
GND
3
4
RSV
RSV
1RefClk+
1PETp1
1RefClk–
1PETn1
5
1PERp0
1PERn0
6
1PETp2
1PETn2
1PERp2
1PERn2
1PERp1
1PERn1
7
1PETp3
1PETn3
1PERp3
1PERn3
1PETp4
1PETn4
8
1PETp5
1PETn5
1PERp5
1PERn5
1PERp4
1PERn4
9
1PETp6
1PETn6
1PERp6
1PERn6
1PETp7
1PETn7
10
RSV
RSV
RSV
RSV
1PERp7
1PERn7
Table B-8. XP4 Connector Pinout for the System Timing Slot
Pin
Z
GND
GND
GND
GND
GND
GND
GND
GND
A
B
C
D
E
F
1
2
3
4
5
6
7
8
GA4
5Vaux
12V
GA3
GND
12V
GA2
GA1
GA0
GND
SYSEN#
GND
WAKE#
GND
3.3V
ALERT#
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
3.3V
3.3V
PXI_TRIG3
PXI_TRIG4
GND
PXI_TRIG5
ATNLED
ATNSW#
RSV
GND
PXI_TRIG6
PXI_CLK10
PXI_TRIG7
PXI_LBR6
PXI_TRIG2
PXI_CLK10_IN
GND
PXI_TRIG1
PXI_TRIG0
GND
PXIe_SYNC_CTRL
PXI_LBL6
NI PXIe-1065 User Manual
B-4
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B
Pinouts
Peripheral Slot Pinouts
Table B-9. P1 Connector Pinout for the Peripheral Slot
Pin
25
24
23
22
21
20
19
18
17
16
15
12–14
11
10
9
Z
A
B
C
D
E
F
GND
5V
REQ64#
5V
ENUM#
V(I/O)
AD[3]
3.3V
3.3V
5V
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
AD[1]
3.3V
AD[0]
5V
ACK64#
AD[2]
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
AD[4]
GND
AD[7]
3.3V
AD[6]
M66EN
AD[11]
GND
AD[5]
AD[9]
GND
AD[8]
V(I/O)
AD[14]
3.3V
C/BE[0]#
AD[10]
AD[13]
C/BE[1]#
PERR#
LOCK#
TRDY#
AD[12]
3.3V
AD[15]
GND
SERR#
3.3V
PAR
IPMB_SCL
GND
IPMB_SDA
V(I/O)
GND
DEVSEL#
3.3V
STOP#
BD_SEL#
FRAME#
IRDY#
Key Area
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
AD[18]
AD[21]
C/BE[3]#
AD[26]
AD[30]
REQ#
AD[17]
GND
AD[16]
3.3V
GND
AD[20]
GND
AD[25]
GND
CLK
C/BE[2]#
AD[19]
AD[22]
AD[24]
AD[27]
AD[31]
GNT#
INTS
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
IDSEL
GND
AD[23]
V(I/O)
AD[28]
3.3V
8
7
AD[29]
GND
6
5
BRSVP1A5
IPMB_PWR
INTA#
BRSVP1B5
HEALTHY
INTB#
5V
RST#
GND
INTP
5V
4
V(I/O)
INTC#
TMS
3
INTD#
TDI
2
TCK
TDO
+12V
1
5V
–12V
TRST#
5V
© National Instruments Corporation
B-5
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B
Pinouts
Table B-10. P2 Connector Pinout for the Peripheral Slot
Pin
Z
A
B
C
D
E
F
22
21
20
19
18
17
16
15
14
13
12
11
10
9
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GA4
GA3
GA2
GA1
GA0
GND
PXI_LBR0
GND
PXI_LBR1
PXI_LBL0
PXI_LBL3
PXI_TRIG5
RSV
PXI_LBR2
GND
PXI_LBR3
PXI_LBL1
PXI_LBL5
PXI_TRIG6
PXI_CLK10
PXI_TRIG7
PXI_LBR6
RSV
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
PXI_LBR4
PXI_LBL2
PXI_TRIG3
PXI_TRIG2
PXI_TRIG1
PXI_LBR5
GND
PXI_LBL4
GND
PXI_TRIG4
GND
PXI_STAR
GND
PXI_TRIG0
GND
RSV
PXI_BRSVA15
RSV
RSV
PXI_LBL6
GND
RSV
RSV
RSV
GND
V(I/O)
RSV
RSV
RSV
RSV
RSV
GND
RSV
RSV
GND
V(I/O)
RSV
RSV
RSV
RSV
RSV
GND
RSV
RSV
GND
V(I/O)
RSV
RSV
RSV
8
RSV
RSV
GND
RSV
7
RSV
GND
V(I/O)
RSV
RSV
RSV
6
RSV
RSV
GND
RSV
5
RSV
GND
V(I/O)
RSV
RSV
RSV
4
V(I/O)
PXI_LBR7
PXI_LBR11
PXI_LBL9
64EN#
GND
GND
RSV
3
PXI_LBR8
UNC
PXI_LBR9
PXI_LBL7
PXI_LBL11
PXI_LBR10
PXI_LBL8
PXI_LBL12
2
PXI_LBR12
GND
1
PXI_LBL10
NI PXIe-1065 User Manual
B-6
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B
Pinouts
Hybrid Slot Pinouts
Table B-11. P1 Connector Pinout for the Hybrid Slot
Pin
25
24
23
22
21
20
19
18
17
16
15
12–14
11
10
9
Z
A
B
C
D
E
F
GND
5V
REQ64#
5V
ENUM#
V(I/O)
AD[3]
3.3V
3.3V
5V
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
AD[1]
3.3V
AD[0]
5V
ACK64#
AD[2]
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
AD[4]
GND
AD[7]
3.3V
AD[6]
M66EN
AD[11]
GND
AD[5]
AD[9]
GND
AD[8]
V(I/O)
AD[14]
3.3V
C/BE[0]#
AD[10]
AD[13]
C/BE[1]#
PERR#
LOCK#
TRDY#
AD[12]
3.3V
AD[15]
GND
SERR#
3.3V
PAR
IPMB_SCL
GND
IPMB_SDA
V(I/O)
GND
DEVSEL#
3.3V
STOP#
BD_SEL#
FRAME#
IRDY#
Key Area
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
AD[18]
AD[21]
C/BE[3]#
AD[26]
AD[30]
REQ#
AD[17]
GND
AD[16]
3.3V
GND
AD[20]
GND
AD[25]
GND
CLK
C/BE[2]#
AD[19]
AD[22]
AD[24]
AD[27]
AD[31]
GNT#
INTS
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
IDSEL
GND
AD[23]
V(I/O)
AD[28]
3.3V
8
7
AD[29]
GND
6
5
BRSVP1A5
IPMB_PWR
INTA#
BRSVP1B5
HEALTHY#
INTB#
5V
RST#
GND
INTP
5V
4
V(I/O)
INTC#
TMS
3
INTD#
TDI
2
TCK
TDO
+12V
1
5V
–12V
TRST#
5V
© National Instruments Corporation
B-7
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B
Pinouts
Table B-12. XP3 Connector Pinout for the Hybrid Slot
Pin
A
B
PXIe_CLK100–
PWREN#
SMBCLK
PERST#
1PETn0
ab
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
C
PXIe_SYNC100+
PXIe_DSTARB+
RSV
D
PXIe_SYNC100–
PXIe_DSTARB–
RSV
cd
E
PXIe_DSTARC+
PXIe_DSTARA+
RSV
F
PXIe_DSTARC–
PXIe_DSTARA–
RSV
ef
1
PXIe_CLK100+
PRSNT#
SMBDAT
MPWRGD*
1PETp0
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
2
3
4
RSV
RSV
1RefClk+
1PETp1
1RefClk-
1PETn1
5
1PERp0
1PERn0
6
1PETp2
1PETn2
1PERp2
1PERn2
1PERp1
1PERn1
7
1PETp3
1PETn3
1PERp3
1PERn3
1PETp4
1PETn4
8
1PETp5
1PETn5
1PERp5
1PERn5
1PERp4
1PERn4
9
1PETp6
1PETn6
1PERp6
1PERn6
1PETp7
1PETn7
10
RSV
RSV
RSV
RSV
1PERp7
1PERn7
Table B-13. XP4 Connector Pinout for the Hybrid Slot
Pin
Z
GND
GND
GND
GND
GND
GND
GND
GND
A
B
C
D
E
F
1
2
3
4
5
6
7
8
GA4
5Vaux
12V
GA3
GND
12V
GA2
GA1
GA0
GND
SYSEN#
GND
WAKE#
GND
3.3V
ALERT#
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
3.3V
3.3V
PXI_TRIG3
PXI_TRIG2
PXI_TRIG1
RSV
PXI_TRIG4
GND
PXI_TRIG5
ATNLED
ATNSW#
RSV
GND
PXI_TRIG6
PXI_CLK10
PXI_TRIG7
PXI_LBR6
PXI_STAR
GND
PXI_TRIG0
GND
PXI_LBL6
NI PXIe-1065 User Manual
B-8
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
C
Technical Support and
Professional Services
Visit the following sections of the award-winning National Instruments
Web site at ni.com for technical support and professional services:
•
Support—Technical support at ni.com/support includes the
following resources:
–
Self-Help Technical Resources—For answers and solutions,
visit ni.com/support for software drivers and updates,
a searchable KnowledgeBase, product manuals, step-by-step
troubleshooting wizards, thousands of example programs,
tutorials, application notes, instrument drivers, and so on.
Registered users also receive access to the NI Discussion Forums
at ni.com/forums. NI Applications Engineers make sure every
question submitted online receives an answer.
–
Standard Service Program Membership—This program
entitles members to direct access to NI Applications Engineers
via phone and email for one-to-one technical support as well as
exclusive access to on demand training modules via the Services
Resource Center. NI offers complementary membership for a full
year after purchase, after which you may renew to continue your
benefits.
For information about other technical support options in your
area, visit ni.com/services, or contact your local office at
ni.com/contact.
•
•
Training and Certification—Visit ni.com/training for
self-paced training, eLearning virtual classrooms, interactive CDs,
and Certification program information. You also can register for
instructor-led, hands-on courses at locations around the world.
System Integration—If you have time constraints, limited in-house
technical resources, or other project challenges, National Instruments
Alliance Partner members can help. To learn more, call your local
NI office or visit ni.com/alliance.
© National Instruments Corporation
C-1
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C
Technical Support and Professional Services
•
Declaration of Conformity (DoC)—A DoC is our claim of
compliance with the Council of the European Communities using
the manufacturer’s declaration of conformity. This system affords
the user protection for electromagnetic compatibility (EMC) and
product safety. You can obtain the DoC for your product by visiting
ni.com/certification.
If you searched ni.com and could not find the answers you need, contact
your local office or NI corporate headquarters. Phone numbers for our
worldwide offices are listed at the front of this manual. You also can visit
the Worldwide Offices section of ni.com/niglobal to access the branch
office Web sites, which provide up-to-date contact information, support
phone numbers, email addresses, and current events.
NI PXIe-1065 User Manual
C-2
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Glossary
Symbol
Prefix
pico
Value
10–12
10–9
10– 6
10–3
103
p
n
nano
micro
milli
kilo
μ
m
k
M
G
T
mega
giga
106
109
tera
1012
Symbols
°
Degrees.
≥
≤
%
Equal or greater than.
Equal or less than.
Percent.
A
A
Amperes.
AC
Alternating current.
ANSI
Auto
AWG
American National Standards Institute.
Automatic fan speed control.
American Wire Gauge.
© National Instruments Corporation
G-1
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Glossary
B
backplane
An assembly, typically a printed circuit board, with connectors and signal
paths that bus the connector pins.
BNC
Bayonet Neill Concelman connector; a commonly used coaxial connector.
C
C
Celsius.
cfm
Cubic feet per minute.
Code of Federal Regulations.
Centimeters.
CFR
cm
CompactPCI
An adaptation of the Peripheral Component Interconnect (PCI)
Specification 2.1 or later for industrial and/or embedded applications
requiring a more robust mechanical form factor than desktop PCI. It
uses industry standard mechanical components and high-performance
connector technologies to provide an optimized system intended for rugged
applications. It is electrically compatible with the PCI Specification, which
enables low-cost PCI components to be utilized in a mechanical form factor
suited for rugged environments.
CSA
Canadian Standards Association.
D
daisy-chain
A method of propagating signals along a bus, in which the devices are
prioritized on the basis of their position on the bus.
DB-9
DC
A 9-pin D-SUB connector.
Direct current.
DoC
Declaration of Conformity.
Subminiature D connector.
D-SUB
NI PXIe-1065 User Manual
G-2
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Glossary
E
efficiency
Ratio of output power to input power, expressed as a percentage.
Electronic Industries Association.
EIA
EMC
EMI
Electromagnetic Compatibility.
Electromagnetic Interference.
F
FCC
Federal Communications Commission.
filler panel
A blank module front panel used to fill empty slots in the chassis.
G
g
(1) grams; (2) a measure of acceleration equal to 9.8 m/s2.
General Purpose Interface Bus (IEEE 488).
GPIB
gRMS
A measure of random vibration. The root mean square of acceleration
levels in a random vibration test profile.
H
hr
Hours.
Hz
Hertz; cycles per second.
I
IEC
International Electrotechnical Commission; an organization that sets
international electrical and electronics standards.
IEEE
IMP
Institute of Electrical and Electronics Engineers.
Mainframe peak current.
© National Instruments Corporation
G-3
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Glossary
in.
Inches.
inhibit
To turn off.
J
jitter
A measure of the small, rapid variations in clock transition times from their
nominal regular intervals. Units: seconds RMS.
K
kg
Kilograms.
Kilometers.
km
L
lb
Pounds.
LED
Light emitting diode.
line regulation
The maximum steady-state percentage that a DC voltage output will
change as a result of a specified change in input AC voltage (step change
from 90 to 132 VAC or 180 to 264 VAC).
load regulation
The maximum steady-state percentage that a DC voltage output will
change as a result of a step change from no-load to full-load output current.
M
m
Meters.
MHz
mi
Megahertz. One million Hertz; one Hertz equals one cycle per second.
Miles.
ms
Milliseconds.
MTBF
MTTR
Mean time between failure.
Mean time to repair.
NI PXIe-1065 User Manual
G-4
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Glossary
N
NEMA
National Electrical Manufacturers Association.
National Instruments.
NI
P
power supply shuttle
A removable module that contains the chassis power supply.
PCI eXtensions for Instrumentation.
PXI
PXI_CLK10
10 MHz PXI system reference clock.
R
RH
Relative humidity.
Root mean square.
RMS
S
s
Seconds.
skew
Deviation in signal transmission times.
slot blocker
An assembly installed into an empty slot to improve the airflow in adjacent
slots.
standby
The backplane is unpowered (off), but the chassis is still connected to AC
power mains.
System controller
A module configured for installation in Slot 1of a PXI chassis. This device
is unique in the PXI system in that it performs the system controller
functions, including clock sourcing and arbitration for data transfers across
the backplane. Installing such a device into any other slot can damage the
device, the PXI backplane, or both.
© National Instruments Corporation
G-5
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Glossary
system reference
clock
A 10 MHz clock, also called PXI_CLK10, that is distributed to all
peripheral slots in the chassis, as well as a BNC connector on the rear of
chassis labeled 10 MHz REF OUT. The system reference clock can be used
for synchronization of multiple modules in a measurement or control
system. The 10 MHz REF IN and OUT BNC connectors on the rear of the
chassis can be used to synchronize multiple chassis to one reference clock.
The PXI backplane specification defines implementation guidelines for
PXI_CLK10.
System Timing slot
This slot is located at slot 4 and has dedicated trigger lines to other slots.
T
TTL
Transistor-transistor logic.
U
UL
Underwriter’s Laboratories.
V
V
Volts.
VAC
Vpp
Volts alternating current.
Peak-to-peak voltage.
W
W
Watts.
NI PXIe-1065 User Manual
G-6
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
CompactPCI
A
AC power cables (table), 1-2
and operation
B
backplane
hybrid peripheral slots, 1-7
interoperability with CompactPCI, 1-6
overview, 1-6
PXI Express peripheral slots, 1-8
PXI local bus, routing, 1-9
PXI peripheral slots, 1-7
PXIe_SYNC_CTRL, 1-14
specifications, A-7
air cooling of PXIe-1065 chassis, 2-2
filler panel installation, 2-5
system controller slot, 1-6
system reference clock, 1-11
default behavior (figure), 1-12
system timing slot, 1-8
D
DB-9 connector
pinout (table), 2-10
power supply voltages (table), 2-11
Declaration of Conformity (NI resources), C-2
diagnostic tools (NI resources), C-1
dimensions (figure), A-11, A-12
documentation
C
cables, power (table), 1-2
CE compliance, specifications, A-6
chassis ambient temperature definitions, 2-4
chassis cooling considerations
ambient temperature definitions, 2-4
clearances, 2-2
figure, 2-3
vents (figure), 2-4
electromagnetic compatibility, A-5
EMC filler panel kit, 1-5
environmental management, specifications, A-6
WEEE information, A-6
examples (NI resources), C-1
external clock source specifications, A-8
chassis initialization file, 2-16
chassis ventilation (figure), 2-4
clearances for chassis cooling, 2-2
figure, 2-3
CLK10 rear connectors, 2-12
© National Instruments Corporation
I-1
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
setting fan speed, 2-5
site considerations, 2-2
slot blocker installation, 2-5
testing power up, 2-6
F
fan, setting speed, 2-5
filler panel installation, 2-5
unpacking the PXIe-1065, 1-1
installing a PXI Express system controller
instrument drivers (NI resources), C-1
G
ground, connecting, 2-5
H
help, technical support, C-1
hybrid peripheral slots, description, 1-7
hybrid slot pinouts
K
kit contents, 1-1
XP4 connector (table), B-8
I
IEC 320 inlet, 1-5, 2-6
inhibit mode switch, 2-12
installation, configuration, and operation
chassis initialization file, 2-16
configuration in MAX (figure), 2-13
connecting safety ground, 2-5
filler panel installation, 2-5
controller, 2-6
M
maintenance of NI PXIe-1065 chassis, 3-1
cleaning
interior cleaning, 3-1
preparation, 3-1
resetting the AC mains circuit
breaker, 3-2
module installation
static discharge damage (caution), 3-1
figure, 2-9
services, C-1
PXI Express system controller installed in
a NI PXIe-1065 chassis (figure), 2-8
rack mounting, 2-5
NI PXIe-1065
fan speed, setting, 2-5
front view (figure), 1-4
installation. See installation,
configuration, and operation
remote voltage monitoring and inhibiting
interface, 2-10
NI PXIe-1065 User Manual
I-2
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
key features, 1-2
NI PXIe-1065 chassis
optional equipment, 1-5
rack mounting, 2-5
connecting to, 2-6
interface, 2-10
replacing, 3-3
rear view of NI PXIe-1065 chassis, 1-5
safety ground, connecting, 2-5
unpacking, 1-1
configuration, 3-4
installation, 3-3
NI PXIe-1065 backplane
hybrid peripheral slots, 1-7
interoperability with CompactPCI, 1-6
overview, 1-6
removal, 3-3
voltages at voltage monitoring connector
(DB-9) (table), 2-10
PXI Express peripheral slots, 1-8
PXI local bus, routing, 1-9
PXI peripheral slots, 1-7
PXIe_SYNC_CTRL, 1-14
using as restart (figure), 1-14
specifications, A-7
system controller slot, 1-6
system reference clock, 1-11
default behavior (figure), 1-12
routing (figure), 1-12
PXI differential star trigger specifications
(PXIe-DSTARA, PXIe-DSTARB,
installing in a NI PXIe-1065 chassis
(figure), 2-8
system timing slot, 1-8
PXI local bus, routing, 1-9
PXI peripheral slots, description, 1-7
PXI star trigger specifications, A-9
PXI star, routing, 1-9
trigger bus, 1-10
NI support and services, C-1
O
PXI-1 configuration in MAX, 2-13
PXIe_DSTAR, routing, 1-9
PXIe_SYNC_CTRL, 1-14
PXIe_SYNC_CTRL specifications, A-9
optional equipment, 1-5
P
peripheral module installation, 2-8
figure, 2-9
peripheral slot pinouts
rack mount kit dimensions (figure), A-13
rack mounting, 2-5
P1 connector (table), B-5
P2 connector (table), B-6
pinouts, B-1
kit, 1-5
recycling hardware, A-6
related documentation, viii
DB-9 connector (table), 2-10
power cables (table), 1-2
power inhibit switch LED indicator, 2-10
© National Instruments Corporation
I-3
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
remote voltage monitoring and inhibiting
interface, 2-10
replacing the power supply, 3-3
mechanical, A-9
PXI differential star triggers
PXIe-DSTARC), A-9
S
PXI star trigger, A-9
safety and caution notices, 2-1
safety ground, connecting, 2-5
safety, specifications, A-5
service interval, 3-1
setting fan speed, 2-5
slot blocker
PXIe_SYNC_CTRL, A-9
rack mount kit dimensions (figure), A-13
safety, A-5
shock and vibration, A-4
system reference clocks, A-7
static discharge damage (caution), 3-1
support, technical, C-1
system controller slot
installation, 2-5
kit, 1-6
software (NI resources), C-1
specifications
description, 1-6
pinouts
XP1 connector (table), B-2
XP2 connector (table), B-2
XP3 connector (table), B-2
XP4 connector (table), B-3
system reference clock, 1-11
default behavior (figure), 1-12
routing (figure), 1-12
sound pressure level (at operator
backplane
100 MHz system reference clock
specifications, A-7
system timing slot
description, 1-8
pinouts
PXIe_SYNC100), A-7
CE compliance, A-6
chassis cooling, A-3
dimensions (figure), A-11, A-12
electrical
TP1 connector (table), B-3
AC input, A-1
DC output, A-2
electromagnetic compatibility, A-5
environmental
technical support, C-1
operating environment, A-4
storage environment, A-4
environmental management, A-6
WEEE information, A-6
external clock source, A-8
testing power up, 2-6
training and certification (NI resources), C-1
trigger bus, 1-10
troubleshooting (NI resources), C-1
NI PXIe-1065 User Manual
I-4
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
U
unpacking the NI PXIe-1065 chassis, 1-1
Web resources, C-1
WEEE information, A-6
V
voltage monitoring connector. See DB-9
connector
voltages at voltage monitoring connector
(DB-9) (table), 2-11
© National Instruments Corporation
I-5
NI PXIe-1065 User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
|