National Instruments Network Card NI PXIe 1065 User Manual

TM  
PXI Express  
NI PXIe-1065 User Manual  
NI PXIe-1065 User Manual  
December 2008  
371990B-01  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Important Information  
Warranty  
The NI PXIe-1065 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced  
by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the  
warranty period. This warranty includes parts and labor.  
The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects in  
materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other documentation. National Instruments  
will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects  
during the warranty period. National Instruments does not warrant that the operation of the software shall be uninterrupted or error free.  
A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before any  
equipment will be accepted for warranty work. National Instruments will pay the shipping costs of returning to the owner parts which are covered by  
warranty.  
National Instruments believes that the information in this document is accurate. The document has been carefully reviewed for technical accuracy. In  
the event that technical or typographical errors exist, National Instruments reserves the right to make changes to subsequent editions of this document  
without prior notice to holders of this edition. The reader should consult National Instruments if errors are suspected. In no event shall National  
Instruments be liable for any damages arising out of or related to this document or the information contained in it.  
EXCEPT AS SPECIFIED HEREIN, NATIONAL INSTRUMENTS MAKES NO WARRANTIES, EXPRESS OR IMPLIED, AND SPECIFICALLY DISCLAIMS ANY WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. CUSTOMERS RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF NATIONAL  
INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER. NATIONAL INSTRUMENTS WILL NOT BE LIABLE FOR DAMAGES RESULTING  
FROM LOSS OF DATA, PROFITS, USE OF PRODUCTS, OR INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF ADVISED OF THE POSSIBILITY THEREOF. This limitation of  
the liability of National Instruments will apply regardless of the form of action, whether in contract or tort, including negligence. Any action against  
National Instruments must be brought within one year after the cause of action accrues. National Instruments shall not be liable for any delay in  
performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunctions, or service  
failures caused by owner’s failure to follow the National Instruments installation, operation, or maintenance instructions; owner’s modification of the  
product; owner’s abuse, misuse, or negligent acts; and power failure or surges, fire, flood, accident, actions of third parties, or other events outside  
reasonable control.  
Copyright  
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying,  
recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National  
Instruments Corporation.  
National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other  
intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only  
to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.  
Trademarks  
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section  
on ni.com/legal for more information about National Instruments trademarks.  
Other product and company names mentioned herein are trademarks or trade names of their respective companies.  
Members of the National Instruments Alliance Partner Program are business entities independent from National Instruments and have no agency,  
partnership, or joint-venture relationship with National Instruments.  
Patents  
For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software,  
the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents.  
WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS  
(1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL OF  
RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN  
ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT  
INJURY TO A HUMAN.  
(2) IN ANY APPLICATION, INCLUDING THE ABOVE, RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE  
IMPAIRED BY ADVERSE FACTORS, INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY,  
COMPUTER HARDWARE MALFUNCTIONS, COMPUTER OPERATING SYSTEM SOFTWARE FITNESS, FITNESS OF COMPILERS  
AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION, INSTALLATION ERRORS, SOFTWARE AND HARDWARE  
COMPATIBILITY PROBLEMS, MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL DEVICES,  
TRANSIENT FAILURES OF ELECTRONIC SYSTEMS (HARDWARE AND/OR SOFTWARE), UNANTICIPATED USES OR MISUSES, OR  
ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER (ADVERSE FACTORS SUCH AS THESE ARE HEREAFTER  
COLLECTIVELY TERMED “SYSTEM FAILURES”). ANY APPLICATION WHERE A SYSTEM FAILURE WOULD CREATE A RISK OF  
HARM TO PROPERTY OR PERSONS (INCLUDING THE RISK OF BODILY INJURY AND DEATH) SHOULD NOT BE RELIANT SOLELY  
UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE. TO AVOID DAMAGE, INJURY, OR DEATH,  
THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO PROTECT AGAINST SYSTEM FAILURES,  
INCLUDING BUT NOT LIMITED TO BACK-UP OR SHUT DOWN MECHANISMS. BECAUSE EACH END-USER SYSTEM IS  
CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS' TESTING PLATFORMS AND BECAUSE A USER OR APPLICATION  
DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT  
EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY  
RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER  
NATIONAL INSTRUMENTS PRODUCTS ARE INCORPORATED IN A SYSTEM OR APPLICATION, INCLUDING, WITHOUT  
LIMITATION, THE APPROPRIATE DESIGN, PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About This Manual  
Chapter 1  
PXI Express Peripheral Slots...........................................................................1-8  
System Timing Slot.........................................................................................1-8  
PXI Trigger Bus ..............................................................................................1-10  
Chapter 2  
Setting Fan Speed............................................................................................2-5  
Installing Filler Panels.....................................................................................2-5  
Installing Slot Blockers ...................................................................................2-5  
Rack Mounting ..............................................................................................................2-5  
Connecting Safety Ground.............................................................................................2-5  
Connecting to Power Source..........................................................................................2-6  
© National Instruments Corporation  
v
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
PXI_CLK10 Rear Connectors....................................................................................... 2-12  
PXI Express System Configuration with MAX ............................................................ 2-12  
Trigger Configuration in MAX....................................................................... 2-14  
Chapter 3  
Replacing the Modular Power Supply........................................................................... 3-3  
Removal .......................................................................................................... 3-3  
Configuration .................................................................................................. 3-4  
Connecting Safety Ground.............................................................................. 3-4  
Connecting to Power Source........................................................................... 3-4  
Appendix A  
Specifications  
Appendix B  
Pinouts  
Technical Support and Professional Services  
Glossary  
Index  
NI PXIe-1065 User Manual  
vi  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About This Manual  
The NI PXIe-1065 User Manual describes the features of the NI PXIe-1065  
chassis and contains information about configuring the chassis, installing  
the modules, and operating the chassis.  
Conventions  
The following conventions are used in this manual:  
»
The » symbol leads you through nested menu items and dialog box options  
to a final action. The sequence File»Page Setup»Options directs you to  
pull down the File menu, select the Page Setup item, and select Options  
from the last dialog box.  
This icon denotes a note, which alerts you to important information.  
This icon denotes a caution, which advises you of precautions to take to  
avoid injury, data loss, or a system crash. When this symbol is marked on  
the product, refer to the Read Me First: Safety and Radio-Frequency  
Interference document, shipped with the product, for precautions to take.  
bold  
Bold text denotes items that you must select or click in the software, such  
as menu items and dialog box options. Bold text also denotes parameter  
names.  
italic  
Italic text denotes variables, emphasis, a cross-reference, or an introduction  
to a key concept. Italic text also denotes text that is a placeholder for a word  
or value that you must supply.  
monospace  
Text in this font denotes text or characters that you should enter from the  
keyboard, sections of code, programming examples, and syntax examples.  
This font is also used for the proper names of disk drives, paths, directories,  
programs, subprograms, subroutines, device names, functions, operations,  
variables, filenames, and extensions.  
© National Instruments Corporation  
vii  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
About This Manual  
Related Documentation  
The following documents contain information that you might find helpful  
as you read this manual:  
IEEE 1101.1-1991, IEEE Standard for Mechanical Core  
Specifications for Microcomputers Using IEC 603-2 Connectors  
IEEE 1101.10, IEEE Standard for Additional Mechanical  
Specifications for Microcomputers Using IEEE 1101.1 Equipment  
Practice  
PICMG EXP.0 R1.0 CompactPCI Express Specification,  
PCI Industrial Computers Manufacturers Group  
PCI Express Base Specification, Revision 1.1, PCI Special Interest  
Group  
PXI-5 PXI Express Hardware Specification, Revision 1.0,  
PXI Systems Alliance  
NI PXIe-1065 User Manual  
viii  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
1
Getting Started  
This chapter describes the key features of the NI PXIe-1065 chassis and  
lists the kit contents and optional equipment you can order from National  
Instruments.  
Unpacking  
Carefully inspect the shipping container and the chassis for damage. Check  
for visible damage to the metal work. Check to make sure all handles,  
hardware, and switches are undamaged. Inspect the inner chassis for any  
possible damage, debris, or detached components. If damage appears to  
have been caused during shipment, file a claim with the carrier. Retain the  
packing material for possible inspection and/or reshipment.  
What You Need to Get Started  
The NI PXIe-1065 chassis kit contains the following items:  
NI PXIe-1065 chassis  
Filler panels  
AC power cable—refer to Table 1-1 for AC power cables  
NI PXIe-1065 User Manual  
Software media with PXI Platform Services 2.0 or higher  
Read Me First: Safety and Radio-Frequency Interference  
Chassis number labels  
© National Instruments Corporation  
1-1  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
Chapter 1  
Getting Started  
Table 1-1. AC Power Cables  
Reference Standards  
Power Cable  
Standard 120 V (USA)  
Switzerland 220 V  
ANSI C73.11/NEMA 5-15-P/IEC83  
SEV  
Australia 240 V  
AS C112  
Universal Euro 230 V  
North America 120 V  
United Kingdom 230 V  
CEE (7), II, IV, VII IEC83  
ANSI C73.20/NEMA 5-15-P/IEC83  
BS 1363/IEC83  
If you are missing any of the items listed in Table 1-1, or if you have the  
incorrect AC power cable, contact National Instruments.  
Key Features  
The NI PXIe-1065 chassis combines a high-performance 18-slot  
PXI Express backplane with a high-output power supply and a structural  
design that has been optimized for maximum usability in a wide range  
of applications. The chassis’ modular design ensures a high level of  
maintainability, resulting in a very low mean time to repair (MTTR).  
The NI PXIe-1065 chassis fully complies with the PXI-5 PXI Express  
Hardware Specification, offering advanced timing and synchronization  
features.  
The key features of the NI PXIe-1065 chassis include the following:  
High Performance for Instrumentation Requirements  
Up to 1 GB/s (single direction) per PXI Express slot dedicated  
bandwidth (x4 PCIe)  
30 W per slot cooling meets increased PXIe cooling requirements  
Low-jitter internal 10 MHz reference clock for PXI slots with  
25 ppm stability  
Low-jitter internal 100 MHz reference clock for PXIe slots with  
25 ppm stability  
Quiet operation for 0 to 30 °C at 43.6 dBA  
NI PXIe-1065 User Manual  
1-2  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Chapter 1  
Getting Started  
Variable speed fan controller optimizes cooling and acoustic emissions  
Remote power-inhibit control  
Complies with PXI and CompactPCI Specifications  
High Reliability  
0 to 55 °C extended temperature range  
Power supply, temperature, and fan monitoring  
HALT tested for increased reliability  
Field replaceable power supply shuttle  
Multi-Chassis Support  
PXIe System Timing Slot for tight synchronization across chassis  
Rear CLK10 I/O connectors  
Switchless CLK10 routing  
Optional Features  
Front and rear rack-mount kits  
Replacement power supply shuttle  
EMC filler panels  
Slot blockers for improved cooling performance  
Factory installation services  
© National Instruments Corporation  
1-3  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1  
Getting Started  
Chassis Description  
Figures 1-1 and 1-2 show the key features of the NI PXIe-1065 chassis  
front and back panels. Figure 1-1 shows the front view of the  
NI PXIe-1065. Figure 1-2 shows the rear view of the NI PXIe-1065.  
2
3
4
NI PXIe-1065  
5
1
13  
H
1
2
3
4
5
6
7
8
9
10  
11 H  
12 H  
13 H  
14  
15  
16  
17  
18  
12  
5
10  
6
8
9
8
7
6
11  
1
2
3
4
5
6
7
Chassis Carry Handle  
Backplane Connectors  
PXI Filler Panels  
Chassis Model Name  
Removable Feet  
PXI Peripheral Slots (9x)  
PXI Express System Timing Slot  
8
9
PXI Express Hybrid Peripheral Slots (4x)  
PXI Express Peripheral Slots (3x)  
10 PXI Express System Controller Slot  
11 Power Inhibit Switch  
12 Power Inhibit Switch LED  
13 System Controller Expansion Slots  
Figure 1-1. Front View of the NI PXIe-1065 Chassis  
NI PXIe-1065 User Manual  
1-4  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Chapter 1  
Getting Started  
6
7
3
4
5
4
8
9
10  
2
1
11  
12  
13  
4
4
14  
1
2
3
4
5
6
7
Universal AC Input  
8
Remote Inhibit and Voltage Monitoring Connector  
Inhibit Mode Selector Switch  
Push-Reset Circuit Breaker  
Chassis Ground Screw  
Fan Guard Retainer Screws  
Power Supply Shuttle ID Label  
10 MHz REF OUT BNC  
10 MHz REF IN BNC  
9
10 Fan Speed Selector Switch  
11 Power Supply Shuttle Mounting Screws (10x)  
12 Power Supply Shuttle Handle (2x)  
13 Power Supply Shuttle  
14 Fan Guard  
Figure 1-2. Rear View of the NI PXIe-1065 Chassis  
Optional Equipment  
Contact National Instruments to order the following options for the  
NI PXIe-1065 chassis.  
EMC Filler Panels  
Optional EMC filler panel kits are available from National Instruments.  
There are two optional kits for mounting the PXIe-1065 chassis into a rack.  
The first option is a pair of mounting brackets for use on the front of the  
chassis. The second option is a rear rack mount kit. The rear rack mount kit  
differs from the front kit to allow for easier installation into the rack.  
For more information, refer to Figure A-3, NI Chassis Rack Mount Kit  
Components.  
© National Instruments Corporation  
1-5  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                 
Chapter 1  
Getting Started  
Slot Blockers  
Optional slot blocker kits are available from National Instruments for  
improved thermal performance when all slots are not used.  
NI PXIe-1065 Chassis Backplane Overview  
This section provides an overview of the backplane features for the  
NI PXIe-1065 chassis.  
Interoperability with CompactPCI  
The design of the NI PXIe-1065 provides you the flexibility to use the  
following devices in a single PXI Express chassis:  
PXI Express compatible products  
CompactPCI Express compatible 4-Link system controller products  
CompactPCI Express compatible Type-2 peripheral products  
PXI peripheral products  
Standard CompactPCI peripheral products  
System Controller Slot  
The system controller slot is Slot 1 of the chassis and is a 4-Link  
configuration system slot as defined by the CompactPCI Express and  
PXI Express specifications. It has three system controller expansion slots  
for system controller modules that are wider than one slot. These slots  
allow the system controller to expand to the left to prevent the system  
controller from using peripheral slots.  
The backplane routes a x4 PCI Express link from the system controller  
slot to slots 7 and 8, and a x1 PCI Express link to a PCI Express to PCI  
Translation Bridge on the backplane. The PCI Express to PCI Translation  
Bridge on the backplane provides a 32-bit/33MHz PCI bus to slots 2 to 7.  
The second PCI Translation Bridge provides PCI bus to slots 11, 12, 13, 15,  
16, 17, and 18 (not to slot 14).  
A x4 link goes to the PXI Express switch and the PCI Express connectivity  
of slots 9 to 14 is connected through the switch.  
The system controller slot also has connectivity to some PXI features such  
as: PXI_CLK10, PXI Star, PXI Trigger Bus and PXI Local Bus 6.  
NI PXIe-1065 User Manual  
1-6  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
Chapter 1  
Getting Started  
By default, the system controller will control the power supply with the  
PS_ON# signals. A logic low on this line will turn the power supply on.  
Note The Inhibit Mode switch on the rear of the chassis must be in the Default position  
for the system controller to have control of the power supply. Refer to the Inhibit Mode  
Switch section of Chapter 2, Installation and Configuration, for details about the Inhibit  
Mode switch.  
Hybrid Peripheral Slots  
The chassis provides four hybrid peripheral slots as defined by the PXI-5  
PXI Express Hardware Specification: slot 7 and slots 11–13. A hybrid  
peripheral slot can accept the following peripheral modules:  
A PXI Express Peripheral with x4 or x1 PCI Express link to the system  
slot or through a switch to the system slot.  
A CompactPCI Express Type-2 Peripheral with x4 or x1 PCI Express  
link to the system slot or through a switch to the system slot.  
A hybrid-compatible PXI Peripheral module that has been modified by  
replacing the J2 connector with an XJ4 connector installed in the upper  
eight rows of J2. Refer to the PXI Express Specification for details. The  
PXI Peripheral communicates through the backplane’s 32-bit PCI bus.  
A CompactPCI 32-bit peripheral on the backplane’s 32-bit PCI bus.  
The hybrid peripheral slots provide full PXI Express functionality and  
32-bit PXI functionality except for PXI Local Bus. The hybrid peripheral  
slot only connects to PXI Local Bus 6 left and right.  
PXI Peripheral Slots  
There are nine PXI peripheral slots which will accept PXI or CompactPCI  
peripherals: slots 2–6 and slots 15–18. These slots are on the backplane’s  
32-bit PCI busses. These slots offer full PXI functionality, but have no  
PXI Express features. The 64-bit PCI signals on the P2 connectors are not  
connected.  
© National Instruments Corporation  
1-7  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Chapter 1  
Getting Started  
PXI Express Peripheral Slots  
There are three PXI Express peripheral slots: slots 8–10. Slot 8 is directly  
connected to the system slot with a x4 PCI Express link. Slots 9 and 10 are  
connected to the system slot through a PCI Express switch. PXI Express  
peripheral slots can accept the following modules:  
A PXI Express Peripheral with x4 or x1 PCI Express link to the system  
slot or through a switch to the system slot.  
A CompactPCI Express Type-2 Peripheral with x4 or x1 PCI Express  
link to the system slot or through a switch to the system slot.  
System Timing Slot  
The System Timing Slot is slot 14. The system timing slot will accept the  
following peripheral modules:  
A PXI Express System Timing Module with x4 or x1 PCI Express link  
to the system slot through a PCIe switch.  
A PXI Express Peripheral with x4 or x1 PCI Express link to the system  
slot through a PCIe switch.  
A CompactPCI Express Type-2 Peripheral with x4 or x1 PCI Express  
link to the system slot through a PCIe switch.  
The system timing slot has 3 dedicated differential pairs (PXIe_DSTAR)  
connected from the TP1 and TP2 connectors to the XP3 connector for each  
PXI Express peripheral or hybrid peripheral slot, as well as routed back to  
the XP3 connector of the system timing slot as shown in Figure 1-3. The  
PXIe_DSTAR pairs can be used for high-speed triggering, synchronization  
and clocking. Refer to the PXI Express Specification for details.  
The system timing slot also has a single-ended (PXI Star) trigger connected  
to every slot. Refer to Figure 1-3 for details.  
The system timing slot has a pin (PXI_CLK10_IN) through which a system  
timing module may source a 10MHz clock to which the backplane will  
phase-lock. Refer to the System Reference Clock section for details.  
The system timing slot has a pin (PXIe_SYNC_CTRL) through which a  
system timing module can control the PXIe_SYNC100 timing. Refer to the  
PXI Express Specification and the PXIe_SYNC_CTRL section of this  
chapter for details.  
NI PXIe-1065 User Manual  
1-8  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Chapter 1  
Getting Started  
PXI STAR 16  
PXI STAR 14  
PXI STAR 15  
PXI STAR 12  
PXI STAR 13  
PX DSTAR 10  
PX STAR 11  
PXI STAR 8  
PXI STAR 4  
PXI STAR 2  
PXI STAR 0  
PXI STAR 1  
PXI STAR 9  
PXI STAR 7  
PXI STAR 6  
PXI STAR 3  
PXI STAR 5  
8
10  
H
H
2
4
11 H 12 H 13  
14  
15  
16  
17  
18  
5
6
7
1
PXIe_DSTAR 1  
PXIe_DSTAR 2  
PXIe_DSTAR 3  
PXIe_DSTAR 4  
PXIe_DSTAR 5  
PXIe_DSTAR 6  
Figure 1-3. PXIe_DSTAR and PXI Star Connectivity Diagram  
PXI Local Bus  
The PXI backplane local bus is a daisy-chained bus that connects each  
peripheral slot with adjacent peripheral slots to the left and right, as shown  
in Figure 1-4.  
The backplane routes the full 13-line PXI Local Bus between adjacent PXI  
slots (slots 2–6 and 15–18) and PXI Local Bus 6 between all other slots.  
Refer to Figure 1-4 for details. The left local bus 6 from slot 1 is not routed  
anywhere and the right local bus signals from slot 18 are not routed  
anywhere.  
© National Instruments Corporation  
1-9  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Chapter 1  
Getting Started  
Local bus signals may range from high-speed TTL signals to analog signals  
as high as 42 V.  
Initialization software uses the configuration information specific to each  
adjacent peripheral module to evaluate local bus compatibility.  
PXI  
PXI  
Trigger Bus  
Buffer Bridge  
Trigger Bus  
Buffer Bridge  
PXI Trigger Bus Segment 2  
PXI Trigger Bus Segment 3  
PXI Trigger Bus Segment 1  
8
10  
H
H
2
4
11 H 12 H 13  
14  
15  
16  
17  
18  
5
6
7
1
Figure 1-4. PXI Trigger Bus and Local Bus Connectivity Diagram  
PXI Trigger Bus  
All slots on the same PXI bus segment share eight PXI trigger lines. You  
can use these trigger lines in a variety of ways. For example, you can use  
triggers to synchronize the operation of several different PXI peripheral  
modules. In other applications, one module located in the system timing  
slot can control carefully timed sequences of operations performed on other  
modules in the system. Modules can pass triggers to one another, allowing  
precisely timed responses to asynchronous external events the system is  
monitoring or controlling.  
The PXI trigger lines from adjacent PXI trigger bus segments can be routed  
in either direction across the PXI trigger bridges through buffers. This  
allows you to send trigger signals to, and receive trigger signals from, every  
slot in the chassis. Static trigger routing (user-specified line and directional  
NI PXIe-1065 User Manual  
1-10  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Chapter 1  
Getting Started  
assignments) can be configured through Measurement & Automation  
Explorer (MAX). Dynamic routing of triggers (automatic line assignments)  
is supported through certain National Instruments drivers like NI-DAQmx.  
Note Although any trigger line may be routed in either direction, it cannot be routed in  
more than one direction at a time.  
System Reference Clock  
The PXIe-1065 chassis supplies the PXI 10 MHz system clock signal  
(PXI_CLK10) independently driven to each peripheral slot and  
PXIe_CLK100 and PXIe_SYNC100 to the PXI Express slots, hybrid slots,  
and system timing slot.  
An independent buffer (having a source impedance matched to the  
backplane and a skew of less than 1 ns between slots) drives PXI_CLK10  
to each peripheral slot. Refer to Figure 1-5 for the routing configuration of  
PXI_CLK10. You can use this common reference clock signal to  
synchronize multiple modules in a measurement or control system.  
An independent buffer drives PXIe_CLK100 to the PXI Express peripheral  
slots, hybrid peripheral slots, and system timing slot. Refer to Figure 1-5  
for the routing configuration of PXIe_CLK100. These clocks are matched  
in skew to less than 100 ps. The differential pair must be terminated on the  
peripheral with LVPECL termination for the buffer to drive PXIe_CLK100  
so that when there is no peripheral or a peripheral that does not connect to  
PXIe_CLK100, there is no clock being driven on the pair to that slot.  
An independent buffer drives PXIe_SYNC100 to the PXI Express  
peripheral slots, hybrid peripheral slots, and system timing slot. Refer  
to Figure 1-5 for the routing configuration of PXIe_SYNC100. The  
differential pair must be terminated on the peripheral with LVPECL  
termination for the buffer to drive PXIe_SYNC100 so that when there is  
no peripheral or a peripheral that does not connect to PXIe_SYNC100,  
there is no SYNC100 signal being driven on the pair to that slot.  
© National Instruments Corporation  
1-11  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Chapter 1  
Getting Started  
10 MHz  
REF IN  
10 MHz  
REF OUT  
PXI_CLK10_IN  
PXI_CLK10  
8
10  
H
H
2
4
11 H 12 H 13  
14  
15  
16  
17  
18  
5
6
7
1
Figure 1-5. Distribution of PXI_CLK10, PXIe_CLK100, and PXIe_SYNC100  
PXI_CLK10, PXIe_CLK100 and PXIe_SYNC100 have the default timing  
relationship described in Figure 1-6.  
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
PXIe_CLK100  
PXI_CLK10  
PXIe_SYNC100  
Figure 1-6. System Reference Clock Default Behavior  
To synchronize the system to an external clock, you can drive PXI_CLK10  
from an external source through the PXI_CLK10_IN pin on the System  
Timing Slot. Refer to Table B-8, XP4 Connector Pinout for the System  
Timing Slot, for the pinout. When a 10MHz clock is detected on this pin,  
the backplane automatically phase-locks the PXI_CLK10, PXIe_CLK100,  
and PXIe_SYNC100 signals to this external clock and distributes these  
NI PXIe-1065 User Manual  
1-12  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Chapter 1  
Getting Started  
signals to the slots (refer to Figure 1-5 for the distribution of PXI_CLK10,  
PXIe_CLK100 and PXIe_SYNC100). Refer to Appendix A,  
Specifications, for the specification information for an external clock  
provided on the PXI_CLK10_IN pin of the system timing slot.  
You also can drive a 10MHz clock on the 10 MHz REF IN connector on the  
rear of the chassis. When a 10MHz clock is detected on this connector, the  
backplane automatically phase-locks the PXI_CLK10, PXIe_CLK100, and  
PXIe_SYNC100 signals to this external clock and distributes these signals  
to the slots (refer to Figure 1-5 for the distribution of PXI_CLK10,  
PXIe_CLK100 and PXIe_SYNC100). Refer to Appendix A,  
Specifications, for the specification information for an external clock  
provided on the 10 MHz REF IN connector on the rear panel of the chassis.  
If the 10 MHz clock is present on both the PXI_CLK10_IN pin of the  
System Timing Slot and the 10 MHz REF IN connector on the rear of the  
chassis, the signal on the System Timing Slot is selected. Refer to Table 1-2  
which explains how the 10 MHz clocks are selected by the backplane.  
Table 1-2. Backplane External Clock Input Truth Table  
System Timing Slot  
PXI_CLK10_IN  
Rear Chassis Panel  
10 MHz REF IN  
Backplane PXI_CLK10, PXIe_CLK100  
and PXIe_SYNC100  
No clock present  
No clock present  
No clock present  
Backplane generates its own clocks  
10 MHz clock present  
PXI_CLK10, PXIe_CLK100 and  
PXIe_SYNC100 all phase-locked to Rear  
Chassis Panel—10 MHz REF IN  
10 MHz clock present  
10 MHz clock present  
No clock present  
PXI_CLK10, PXIe_CLK100 and  
PXIe_SYNC100 all phase-locked to  
System Timing Slot— PXI_CLK10_IN  
10 MHz clock present  
PXI_CLK10, PXIe_CLK100 and  
PXIe_SYNC100 all phase-locked to  
System Timing Slot—PXI_CLK10__IN  
A copy of the backplane’s PXI_CLK10 is exported to the 10 MHz REF  
OUT connector on the rear of the chassis. This clock is driven by an  
independent buffer. Refer to Appendix A, Specifications, for the  
specification information for the 10 MHz REF OUT signal on the rear  
panel of the chassis.  
© National Instruments Corporation  
1-13  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 1  
Getting Started  
PXIe_SYNC_CTRL  
PXIe_SYNC100 is by default a 10 ns pulse synchronous to PXI_CLK10.  
The frequency of PXIe_SYNC100 is 10/n MHz, where n is a positive  
integer. The default for n is 1, giving PXIe_SYNC100 a 100 ns period.  
However, the backplane allows n to be programmed to other integers. For  
still maintaining its phase relationship to PXI_CLK10. The value for n may  
be set to any positive integer from 1 to 255.  
The system timing slot has a control pin for PXIe_SYNC100 called  
PXIe_SYNC_CTRL for use when n > 1. Refer to Table B-7, XP3  
Connector Pinout for the System Timing Slot, for system timing slot pinout.  
Refer to Appendix A, Specifications, for the PXIe_SYNC_CTRL input  
specifications.  
By default, a high-level detected by the backplane on the  
PXIe_SYNC_CTRL pin causes a synchronous restart for the  
PXIe_SYNC100 signal. On the next PXI_CLK10 edge the  
PXIe_SYNC100 signal will restart. This will allow several chassis to have  
their PXIe_SYNC100 in phase with each other. Refer to Figure 1-7 for  
timing details with this method.  
PXI_CLK10  
PXIe_SYNC_CTRL  
PXIe_SYNC100  
SYNC100 Divider  
Restarted Here  
Figure 1-7. PXIe_SYNC100 at 3.33 MHz Using PXIe_SYNC_CTRL as Restart  
NI PXIe-1065 User Manual  
1-14  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
2
Installation and Configuration  
This chapter describes how to prepare and operate the NI PXIe-1065  
chassis.  
Before connecting the chassis to a power source, read this chapter and  
the Read Me First: Safety and Radio-Frequency Interference document  
included with your kit.  
Safety Information  
Caution Before undertaking any troubleshooting, maintenance, or exploratory procedure,  
carefully read the following caution notices.  
This equipment contains voltage hazardous to human life and safety, and  
is capable of inflicting personal injury.  
Chassis Grounding—The chassis requires a connection from the  
premise wire safety ground to the chassis ground. The earth safety  
ground must be connected during use of this equipment to minimize  
shock hazards. Refer to the Connecting Safety Ground section for  
instructions on connecting safety ground.  
Live Circuits—Operating personnel and service personnel must not  
remove protective covers when operating or servicing the chassis.  
Adjustments and service to internal components must be undertaken  
by qualified service technicians. During service of this product,  
the mains connector to the premise wiring must be disconnected.  
Dangerous voltages may be present under certain conditions;  
use extreme caution.  
Explosive Atmosphere—Do not operate the chassis in conditions  
where flammable gases are present. Under such conditions, this  
equipment is unsafe and may ignite the gases or gas fumes.  
© National Instruments Corporation  
2-1  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Chapter 2  
Installation and Configuration  
Part Replacement—Only service this equipment with parts that are  
exact replacements, both electrically and mechanically. Contact  
National Instruments for replacement part information. Installation of  
parts with those that are not direct replacements may cause harm to  
personnel operating the chassis. Furthermore, damage or fire may  
occur if replacement parts are unsuitable.  
Modification—Do not modify any part of the chassis from its original  
condition. Unsuitable modifications may result in safety hazards.  
Chassis Cooling Considerations  
The NI PXIe-1065 chassis is designed to operate on a bench or in an  
instrument rack. Regardless of the configuration you must provide the  
cooling clearances as outlined in the following sections.  
Providing Adequate Clearance  
The primary cooling exhaust vent for the NI PXIe-1065 is on the top of the  
chassis. The primary intake vent is on the rear of the chassis. The secondary  
intake and exhaust vents are located along the sides of the chassis.  
Adequate clearance between the chassis and surrounding equipment or  
blockages must be maintained to ensure proper cooling of the chassis  
power supply as well as the modules plugged into the chassis. These  
clearances are outlined in Figure 2-1. The vent locations for the  
NI PXIe-1065 chassis are shown in Figure 2-2. Failure to provide these  
clearances may result in thermal-related failures in the chassis or modules.  
NI PXIe-1065 User Manual  
2-2  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Chapter 2  
Installation and Configuration  
Dimensions are in inches (millimeters)  
1.75  
(44.45)  
1.75  
(44.45)  
NI PXIe-1065  
H
1
2
3
4
5
6
7
8
9
10  
11 H  
12 H  
13 H  
14  
15  
16  
17  
18  
3.00  
(76.20)  
Figure 2-1. NI PXIe-1065 Cooling Clearances  
© National Instruments Corporation  
2-3  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter 2  
Installation and Configuration  
2
1
3
1
2
Primary Air Exhaust Vent  
Primary Air Intake Vent  
3
Secondary Air Intake/Exhaust Vents  
(both sides)  
Figure 2-2. NI PXIe-1065 Vents  
Chassis Ambient Temperature Definition  
The chassis fan control system uses intake air temperature as the input for  
controlling fan speeds when in Auto Fan Speed mode. Because of this, the  
chassis ambient temperature is defined as the temperature that exists just  
outside of the fan intake vents on the rear of the chassis. Note that this  
temperature may be higher than ambient room temperature depending  
on the surrounding equipment and/or blockages present. It is the user’s  
responsibility to ensure that this ambient temperature does not exceed the  
NI PXIe-1065 User Manual  
2-4  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Chapter 2  
Installation and Configuration  
rated ambient temperature as stated in Appendix A, Specifications. If the  
temperature exceeds the stated spec the power switch LED will blink green,  
as discussed in the Power Inhibit Switch LED Indicator section of this  
chapter.  
Setting Fan Speed  
The fan-speed selector switch is on the rear panel of the NI PXIe-1065  
chassis. Refer to Figure 1-2, Rear View of the NI PXIe-1065 Chassis, to  
locate the fan-speed selector switch. Select High for maximum cooling  
performance or Auto for improved acoustic performance. When set to  
Auto, the fan speed is determined by chassis intake air temperature.  
Installing Filler Panels  
To maintain proper module cooling performance, install filler panels  
(provided with the chassis) in unused or empty slots. Secure with the  
captive mounting screws provided.  
Installing Slot Blockers  
The cooling performance of the chassis can be improved by installing  
optional slot blockers. Refer to ni.com for more details.  
Rack Mounting  
Rack mount applications require the optional rack mount kits available  
from National Instruments. Refer to the instructions supplied with the rack  
mount kits to install your NI PXIe-1065 chassis in an instrument rack.  
Refer to Figure A-3, NI Chassis Rack Mount Kit Components.  
Note You may want to remove the feet from the NI PXIe-1065 chassis when rack  
mounting. To do so, remove the screws holding the feet in place.  
Connecting Safety Ground  
Caution The NI PXIe-1065 chassis are designed with a three-position NEMA 5-15 style  
plug for the U.S. that connects the ground line to the chassis ground. To minimize shock  
hazard, make sure the electrical power outlet you use to power the chassis has an  
appropriate earth safety ground.  
© National Instruments Corporation  
2-5  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                     
Chapter 2  
If your power outlet does not have an appropriate ground connection, you  
must connect the premise safety ground to the chassis grounding screw  
located on the rear panel. Refer to Figure 1-2, Rear View of the  
NI PXIe-1065 Chassis, to locate the chassis grounding screw. To connect  
the safety ground, complete the following steps:  
1. Connect a 16 AWG (1.3 mm) wire to the chassis grounding screw  
using a grounding lug. The wire must have green insulation with a  
yellow stripe or must be noninsulated (bare).  
2. Attach the opposite end of the wire to permanent earth ground using  
toothed washers or a toothed lug.  
Connecting to Power Source  
To completely remove power, you must disconnect the AC power cable.  
Attach input power through the rear AC inlet using the appropriate  
AC power cable supplied. Refer to Figure 1-2, Rear View of the  
NI PXIe-1065 Chassis, to locate the AC inlet.  
The Inhibit Mode switch allows you to power on the chassis or place it in  
standby mode. Set the Inhibit Mode switch on the back of the chassis to the  
Manual position. Observe that all fans become operational and the power  
switch LED is a steady green. Switching the Inhibit Mode switch to the  
Default position allows the system controller to control the power supply.  
Installing a PXI Express System Controller  
This section contains general installation instructions for installing a  
PXI Express system controller in a NI PXIe-1065 chassis. Refer to your  
PXI Express system controller user manual for specific instructions and  
warnings. To install a system controller, complete the following steps:  
1. Connect the AC power source to the PXI Express chassis before  
installing the system controller. The AC power cord grounds the  
chassis and protects it from electrical damage while you install the  
system controller.  
2. Install the system controller into the system controller slot (slot 1,  
indicated by the red card guides) by first placing the system controller  
PCB into the front of the card guides (top and bottom). Slide the  
NI PXIe-1065 User Manual  
2-6  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Chapter 2  
Installation and Configuration  
system controller to the rear of the chassis, making sure that the  
injector/ejector handle is pushed down as shown in Figure 2-3.  
4
1
3
2
1
2
NI PXI Express System Controller  
NI PXIe-1065 Chassis  
3
4
Injector/Ejector Handle  
System Controller Front Panel Mounting Screws (4x)  
Figure 2-3. Installing a PXIe System Controller  
3. When you begin to feel resistance, pull up on the injector/ejector  
handle to seat the system controller fully into the chassis frame. Secure  
the system controller front panel to the chassis using the system  
controller front-panel mounting screws.  
4. Connect the keyboard, mouse, and monitor to the appropriate  
connectors. Connect devices to ports as required by your system  
configuration.  
5. Power on the chassis. Verify that the system controller boots. If the  
system controller does not boot, refer to your system controller user  
manual.  
© National Instruments Corporation  
2-7  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter 2  
Installation and Configuration  
Figure 2-4 shows a PXI Express system controller installed in the system  
controller slot of a NI PXIe-1065 chassis. You can place CompactPCI,  
CompactPCI Express, PXI, or PXI Express modules in other slots  
depending on the slot type.  
1
2
3
1
NI PXIe-1065 Chassis  
2
NI PXIe System Controller  
3
Injector/Ejector Rail  
Figure 2-4. NI PXI Express System Controller Installed in a NI PXIe-1065 Chassis  
Caution The NI PXIe-1065 chassis has been designed to accept a variety of peripheral  
module types in different slots. To prevent damage to the chassis, ensure that the peripheral  
module is being installed into a slot designed to accept it. Refer to Chapter 1, Getting  
Started, for a description of the various slot types.  
NI PXIe-1065 User Manual  
2-8  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Chapter 2  
Installation and Configuration  
This section contains general installation instructions for installing a  
peripheral module in a NI PXIe-1065 chassis. Refer to your peripheral  
module user manual for specific instructions and warnings. To install a  
module, complete the following steps:  
1. Connect the AC power source to the PXI Express chassis before  
installing the module. The AC power cord grounds the chassis and  
protects it from electrical damage while you install the module.  
2. Ensure that the chassis is powered off.  
3. Install a module into a chassis slot by first placing the module card  
PCB into the front of the card guides (top and bottom), as shown in  
Figure 2-5. Slide the module to the rear of the chassis, making sure that  
the injector/ejector handle is pushed down as shown in Figure 2-5.  
4. When you begin to feel resistance, push up on the injector/ejector  
handle to fully seat the module into the chassis frame. Secure the  
module front panel to the chassis using the module front-panel  
mounting screws.  
3
2
NI  
PXIe-106  
5
1
6
4
5
1
2
3
Peripheral Module Front Panel Mounting Screws (2x)  
NI PXI Express System Controller  
NI PXIe-1065 Chassis  
4
5
6
Injector/Ejector Rail  
Injector/Ejector Handle  
PXI Peripheral Module  
Figure 2-5. Installing PXI, PXI Express, or CompactPCI Peripheral Modules  
© National Instruments Corporation  
2-9  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter 2  
Installation and Configuration  
Power Inhibit Switch LED Indicator  
The chassis power inhibit switch has an integrated LED. This LED  
indicates one of four different conditions:  
If the inhibit switch LED is steady green (not flashing), the chassis is  
powered on and operating normally.  
If the inhibit switch LED is flashing green, the air-intake temperature  
has exceeded the chassis operating range.  
If the inhibit switch LED is flashing red, the power supply outputs are  
not within voltage regulation requirements.  
If the inhibit switch LED is steady red, the system fans or power supply  
fan has failed. The remaining fans will automatically be driven high.  
Note If two system fans or both of the power supply fans fail the chassis will shut down  
automatically, preventing the chassis and modules from damage due to overheating.  
Remote Voltage Monitoring and Control  
The NI PXIe-1065 chassis supports remote voltage monitoring and  
inhibiting through a female 9-pin D-SUB (DB-9) connector located on  
the rear panel. Table 2-1 shows the pinout of the 9-pin D-SUB (DB-9)  
connector.  
Table 2-1. Remote Inhibit and Voltage Monitoring Connector Pinout  
DB-9 Pin  
Signal  
Logic Ground  
+5 VDC  
1
2
3
4
5
6
7
Reserved  
+3.3 VDC  
Inhibit (Active Low)  
+12 VDC  
Reserved  
NI PXIe-1065 User Manual  
2-10  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Chapter 2  
Installation and Configuration  
Table 2-1. Remote Inhibit and Voltage Monitoring Connector Pinout (Continued)  
DB-9 Pin  
Signal  
–12 VDC  
8
9
Logic Ground  
6
7
8
9
1
2
3
4
5
Caution When connecting digital voltmeter probes to the rear 9-pin D-SUB (DB-9)  
connector, be careful not to short the probe leads together. Doing so could damage the  
power supply.  
You can use a digital voltmeter to ensure all voltage levels in the  
NI PXIe-1065 chassis are within the allowable limits. Referring to  
Table 2-2, connect one lead of the voltmeter to a supply pin on the remote  
voltage monitoring connector (9-pin D-SUB) on the rear panel. Refer to  
Table 2-1 for a pinout diagram of the remote voltage monitoring connector.  
Connect the reference lead of the voltmeter to one of the ground pins.  
Compare each voltage reading to the values listed in Table 2-2.  
Note Use the rear-panel 9-pin D-SUB connector to check voltages only. Do not use the  
connector to supply power to external devices.  
Table 2-2. Power Supply Voltages at Voltage Monitoring Connector (DB-9)  
Pin  
2
Supply  
+5 V  
Acceptable Voltage Range  
4.75 to 5.25 V  
3.135 to 3.465 V  
11.4 to 12.6 V  
–12.6 to –11.4 V  
0 V  
4
+3.3 V  
6
+12 V  
8
–12 V  
1, 9  
Logic Ground  
If the voltages fall within the specified ranges, the chassis complies with the  
CompactPCI voltage-limit specifications.  
© National Instruments Corporation  
2-11  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter 2  
Installation and Configuration  
Inhibit Mode Switch  
On the rear panel of the chassis there is an Inhibit Mode switch. Refer to  
Figure 1-2, Rear View of the NI PXIe-1065 Chassis, for the location. The  
Inhibit Mode switch is recessed to prevent it from accidentally being  
switched.  
The Inhibit Mode switch should be in the Default position when normal  
power inhibit switch functionality is desired. If the user needs to power on  
a chassis without a system controller installed the switch should be in the  
Manual position.  
When the Inhibit Mode switch is set to the Manual position, the power  
supplies are enabled, and you can use the Inhibit signal (active low) on  
pin 5 of the Remote Inhibit and Voltage Monitoring connector to power off  
the chassis. To remotely power off the chassis, connect the Inhibit pin  
(pin 5) to a Logic Ground pin (pin 1 or 9). As long as this connection exists,  
the chassis will remain off (standby); when you remove this connection, the  
chassis turns on.  
Note For the Remote Inhibit signal to control the On/Off (standby) state of the chassis,  
the Inhibit Mode switch must be in the Manual position.  
PXI_CLK10 Rear Connectors  
There are two BNC connectors on the rear of the NI PXIe-1065 chassis for  
PXI_CLK10. The connectors are labeled IN and OUT. You can use them  
for supplying the backplane with PXI_CLK10 or routing the backplane’s  
PXI_CLK10 to another chassis. Refer to the System Reference Clock  
section of Chapter 1, Getting Started, for details about these signals.  
PXI Express System Configuration with MAX  
The PXI Platform Services software included with your chassis  
automatically identifies your PXI Express system components to generate  
a pxiesys.ini file. You can configure your entire PXI system and  
identify PXI-1 chassis through Measurement & Automation Explorer  
(MAX), included with your system controller. MAX creates the  
pxiesys.ini and pxisys.ini file, which define your PXI system  
parameters. MAX also provides an interface to route and reserve triggers  
so dynamic routing, through drivers such as DAQmx, avoids  
NI PXIe-1065 User Manual  
2-12  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
Chapter 2  
Installation and Configuration  
double-driving and potentially damaging trigger lines. For more  
information about routing and reserving PXI triggers, refer to  
KnowledgeBase 3TJDOND8 at ni.com/support.  
The configuration steps for single or multiple-chassis systems are the same.  
Figure 2-6. Multichassis Configuration in MAX  
PXI-1 System Configuration  
1. Launch MAX.  
2. In the Configuration tree, click the Devices and Interfaces branch to  
expand it.  
3. If the PXI system controller has not yet been configured, it is labeled  
PXI System (Unidentified). Right-click this entry to display the  
pop-up menu, then select the appropriate system controller model from  
the Identify As submenu.  
© National Instruments Corporation  
2-13  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Chapter 2  
Installation and Configuration  
4. Click the PXI system controller. The chassis (or multiple chassis, in a  
multichassis configuration) is listed below it. Identify each chassis by  
right-clicking its entry, then selecting the appropriate chassis model  
through the Identify As submenu. Further expanding the PXI System  
branch shows all devices in the system that can be recognized by  
NI-VISA. When your system controller and all your chassis are  
identified, the required pxisys.ini file is complete.  
The PXI specification allows for many combinations of PXI chassis and  
system modules. To assist system integrators, the manufacturers of  
PXI chassis and system modules must document the capabilities of their  
products. PXI Express devices must provide a driver and .ini file for  
identification. These files are provided as part of the PXI Platform Services  
software included with your system controller. The minimum  
documentation requirements for PXI-1 are contained in .ini files, which  
consist of ASCII text. System integrators, configuration utilities, and  
device drivers can use these .ini files.  
The capability documentation for a PXI-1 chassis is contained in a  
chassis.ini file provided by the chassis manufacturer. The information  
in this file is combined with information about the system controller to  
create a single PXI-1 system initialization file called pxisys.ini  
(PXI System Initialization). The NI system controller uses MAX to  
generate the pxisys.ini file from the chassis.ini file.  
Device drivers and other utility software read the pxiesys.ini and  
pxisys.ini file to obtain system information. For detailed information  
about initialization files, refer to the PXI specification at www.pxisa.org.  
Trigger Configuration in MAX  
Each chassis has one or more trigger buses, each with eight lines  
numbered 0 through 7 that can be reserved and routed statically or  
dynamically. Static reservation pre-allocates a trigger line to prevent its  
configuration by a user program. Dynamic reservation/routing/deallocation  
is on the fly within a user program based upon National Instruments APIs  
such as NI-DAQmx. Static reservation of trigger lines can be implemented  
by the user in MAX through the Triggers tab. Reserved trigger lines will  
not be used by PXI modules dynamically configured by programs such as  
NI-DAQmx. This prevents the instruments from double-driving the trigger  
lines, possibly damaging devices in the chassis. In the default  
configuration, trigger lines on each bus are independent. For example,  
if trigger line 3 is asserted on trigger bus 0, by default it will not be  
automatically asserted on any other trigger bus.  
NI PXIe-1065 User Manual  
2-14  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 2  
Installation and Configuration  
Complete the following steps to reserve these trigger lines in MAX.  
1. In the Configuration tree, click on the PXI chassis branch you want to  
configure.  
2. Then, in the right-hand pane, toward the bottom, click on the  
Triggers tab.  
3. Select which trigger lines you would like to statically reserve.  
4. Click the Apply button.  
PXI Trigger Bus Routing  
Some National Instruments chassis, such as the PXI-1065 and the  
PXI-1044/1045, have the capability to route triggers from one bus to others  
within the same chassis using the Trigger Routing tab in MAX, as shown  
in Figure 2-6.  
Note Selecting any non-disabled routing automatically reserves the line in all trigger  
buses being routed to. If you are using NI-DAQmx, it will reserve and route trigger lines  
for you, so you won’t have to route trigger lines manually.  
Complete the following steps to configure trigger routings in MAX.  
1. In the Configuration tree, select the chassis in which you want to  
route trigger lines.  
2. In the right-hand pane, select the Trigger Routing tab near the bottom.  
3. For each trigger line, select Route Right, Route Outward From  
Middle, or Route Left to route triggers on that line in the described  
direction, or select Disabled for the default behavior with no manual  
routing.  
4. Click the Apply button.  
© National Instruments Corporation  
2-15  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 2  
Installation and Configuration  
Using System Configuration and Initialization Files  
The PXI Express specification allows many combinations of PXI Express  
chassis and system modules. To assist system integrators, the  
manufacturers of PXI Express chassis and system modules must document  
the capabilities of their products. The minimum documentation  
requirements are contained in .ini files, which consist of ASCII text.  
System integrators, configuration utilities, and device drivers can use these  
.ini files.  
The capability documentation for the NI PXIe-1065 chassis is contained in  
the chassis.ini file on the software media that comes with the chassis.  
The information in this file is combined with information about the system  
controller to create a single system initialization file called pxisys.ini  
(PXI System Initialization). The system controller manufacturer either  
provides a pxisys.ini file for the particular chassis model that contains  
the system controller or provides a utility that can read an arbitrary  
chassis.ini file and generate the corresponding pxisys.ini file.  
System controllers from NI provide the pxisys.ini file for the  
NI PXIe-1065 chassis, so you should not need to use the chassis.ini  
file. Refer to the documentation provided with the system controller or  
to ni.com/support for more information on pxisys.ini and  
chassis.ini files.  
Device drivers and other utility software read the pxisys.ini file to  
obtain system information. The device drivers should have no need to  
directly read the chassis.ini file. For detailed information regarding  
initialization files, refer to the PXI Express specification at  
NI PXIe-1065 User Manual  
2-16  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3
Maintenance  
This chapter describes basic maintenance procedures you can perform on  
the NI PXIe-1065 chassis.  
Caution Disconnect the power cable prior to servicing a NI PXIe-1065 chassis.  
Service Interval  
Clean dust from the chassis exterior (and interior) as needed, based on the  
operating environment. Periodic cleaning increases reliability.  
Preparation  
The information in this section is designed for use by qualified service  
personnel. Read the Read Me First: Safety and Radio-Frequency  
Interference document included with your kit before attempting any  
procedures in this chapter.  
Caution Many components within the chassis are susceptible to static discharge damage.  
Service the chassis only in a static-free environment. Observe standard handling  
precautions for static-sensitive devices while servicing the chassis. Always wear a  
grounded wrist strap or equivalent while servicing the chassis.  
Cleaning  
Cleaning procedures consist of exterior and interior cleaning of the chassis.  
Refer to your module user documentation for information on cleaning the  
individual CompactPCI or PXI Express modules.  
Caution Always disconnect the AC power cable before cleaning or servicing the chassis.  
Interior Cleaning  
Use a dry, low-velocity stream of air to clean the interior of the chassis.  
Use a soft-bristle brush for cleaning around components.  
© National Instruments Corporation  
3-1  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                   
Chapter 3  
Maintenance  
Exterior Cleaning  
Clean the exterior surfaces of the chassis with a dry lint-free cloth or a  
soft-bristle brush. If any dirt remains, wipe with a cloth moistened in a mild  
soap solution. Remove any soap residue by wiping with a cloth moistened  
with clear water. Do not use abrasive compounds on any part of the chassis.  
Caution Avoid getting moisture inside the chassis during exterior cleaning, especially  
through the top vents. Use just enough moisture to dampen the cloth.  
Do not wash the front- or rear-panel connectors or switches. Cover these components while  
cleaning the chassis.  
Do not use harsh chemical cleaning agents; they may damage the chassis. Avoid chemicals  
that contain benzene, toluene, xylene, acetone, or similar solvents.  
Resetting the AC Mains Circuit Breaker  
If the NI PXIe-1065 chassis is connected to an AC source and encounters  
an over-current condition, the circuit breaker on the rear panel will trip to  
prevent damage to the chassis. Complete the following steps to reset the  
circuit breaker.  
1. Turn off the chassis.  
2. Disconnect the AC power cable.  
3. Depress the circuit breaker to reset it.  
4. Reconnect the AC power cable.  
5. Turn on the chassis.  
If the circuit breaker trips again, complete the following steps:  
1. Turn off the chassis.  
2. Disconnect the AC power cable.  
3. Remove all modules from the chassis.  
4. Complete the procedure described in the Connecting to Power Source  
section of Chapter 2, Installation and Configuration. If the power  
switch LED is not a steady green, contact National Instruments.  
5. Verify that the NI PXIe-1065 chassis can meet the power requirements  
of your CompactPCI or PXI Express modules. Overloading the chassis  
can cause the breaker to trip. Refer to Appendix A, Specifications.  
NI PXIe-1065 User Manual  
3-2  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Chapter 3  
Maintenance  
6. The over-current condition that caused the circuit breaker to trip  
may be due to a faulty CompactPCI or PXI Express module. Refer to  
the documentation supplied with the modules for troubleshooting  
information.  
Replacing the Modular Power Supply  
This section describes how to remove, configure, and install the AC  
power supply shuttle in the NI PXIe-1065 chassis.  
Cautions Disconnect the power cable prior to replacing the power supply.  
Do not attempt to use a power supply shuttle from another chassis such as the  
NI PXI-1044/1045. Doing so may damage your chassis and the power supply shuttle.  
Before connecting the power supply shuttle to a power source, read this  
section and the Read Me First: Safety and Radio-Frequency Interference  
document included with the kit.  
Removal  
NI PXIe-1065 AC chassis. Before attempting to replace the power supply  
shuttle, verify that there is adequate clearance behind the chassis.  
Disconnect the power cable from the power supply shuttle on the back of  
the chassis. Identify the ten mounting screws for the NI PXIe-1065 that  
attach the power supply shuttle to the chassis. Refer to Figure 1-2, Rear  
View of the NI PXIe-1065 Chassis, for the screw locations. Using a Phillips  
screwdriver, remove the screws. Pull on the two rear handles of the power  
supply shuttle to remove it from the back of the chassis.  
Installation  
Ensure that there is no visible damage to the new power supply shuttle.  
Verify that the housing and connector on the new power supply shuttle  
have no foreign material inside. Remove the protective cap on the  
PXI_CLK10 connector. Install the new power supply shuttle into the  
opening on the rear of the chassis. Replace and tighten the ten screws with  
a Phillips screwdriver.  
© National Instruments Corporation  
3-3  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Chapter 3  
Maintenance  
Configuration  
The fan-speed selector switch is on the rear panel of the power supply  
shuttle. Refer to Figure 1-2, Rear View of the NI PXIe-1065 Chassis,  
performance (recommended) or Auto for quieter operation. Set the Inhibit  
Mode switch to the Default position.  
Connecting Safety Ground  
Refer to the Connecting Safety Ground section of Chapter 2, Installation  
and Configuration.  
Connecting to Power Source  
Refer to the Connecting to Power Source section of Chapter 2, Installation  
and Configuration.  
NI PXIe-1065 User Manual  
3-4  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
A
Specifications  
This appendix contains specifications for the NI PXIe-1065 chassis.  
Caution Specifications are subject to change without notice.  
Electrical  
AC Input  
Input voltage range................................. 100 to 240 VAC  
Operating voltage range1........................ 90 to 264 VAC  
Input frequency ...................................... 50/60 Hz  
Operating frequency range1 ................... 47 to 63 Hz  
Input current rating................................. 10–5 A  
Over-current protection.......................... 12 A circuit breaker  
Line regulation  
3.3 V................................................ < 0.2%  
5 V................................................... < 0.1%  
12 V .............................................. < 0.1%  
Efficiency............................................... 70% typical  
Power disconnect ....................................The AC power cable provides  
main power disconnect. The  
front-panel power switch causes  
the internal chassis power supply  
to provide DC power to the  
CompactPCI/PXI Express  
backplane. You also can use the  
rear-panel D-SUB 9-pin connector  
and power mode switch to control  
the internal chassis power supply.  
1
The operating range is guaranteed by design.  
© National Instruments Corporation  
A-1  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Appendix A  
Specifications  
DC Output  
DC current capacity (IMP  
)
Voltage  
+3.3 V  
Maximum Current  
61 A  
56 A  
45 A  
4 A  
+5 V  
+12 V  
–12 V  
5 VAUX  
1.5 A  
Note Maximum combined +3.3 V, +5 V, and +12 V power is 699 W.  
Maximum total power is 701.5 W.  
The maximum power dissipated in the system slot should not exceed 140 W.  
Backplane pin current capacity  
Slot  
+5 V  
9 A  
V (I/O) +3.3 V  
+12 V  
11 A  
2 A  
–12 V  
0 A  
5 VAUX  
1 A  
System Controller Slot  
System Timing Slot  
0 A  
0 A  
5 A  
9 A  
3 A  
6 A  
0 A  
6 A  
0 A  
1 A  
Hybrid Peripheral Slot with  
PXI-1 Peripheral  
1 A  
1 A  
0 A  
Hybrid Peripheral Slot with  
PXI-5 Peripheral  
0 A  
6 A  
0 A  
3 A  
6 A  
3 A  
1 A  
0 A  
1 A  
1 A  
0 A  
PXI-1 Peripheral Slot  
11 A  
Load regulation  
Voltage  
Load Regulation  
+3.3 V  
+12 V  
+5 V  
<5%  
<5%  
<5%  
<5%  
–12 V  
NI PXIe-1065 User Manual  
A-2  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix A  
Specifications  
Maximum ripple and noise (20 MHz bandwidth)  
Voltage  
+3.3 V  
+12 V  
+5 V  
Maximum Ripple and Noise  
50 mVpp  
120 mVpp  
50 mVpp  
–12 V  
120 mVpp  
Over-current protection.......................... All outputs protected from short  
circuit and overload with  
automatic recovery  
Over-voltage protection  
3.3 V and 5 V.................................. Clamped at 20 to 30% above  
nominal output voltage  
Power supply shuttle MTTR.................. Replacement in under 5 minutes  
Chassis Cooling  
Module cooling system  
NI PXIe-1065.................................. Forced air circulation  
(positive pressurization) through  
three 165 cfm fans with  
High/Auto speed selector  
Slot airflow direction ............................. Bottom of module to top of  
module  
Module cooling intake ........................... Bottom rear of chassis  
Module cooling exhaust......................... Along both sides and top of  
chassis  
Power supply cooling system................. Forced air circulation through  
two integrated fans  
Power supply cooling intake.................. Right side of chassis  
Power supply cooling exhaust................ Left side of chassis  
© National Instruments Corporation  
A-3  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix A  
Specifications  
Environmental  
Maximum altitude...................................2,000 m (800 mbar)  
(at 25 °C ambient)  
Pollution Degree.....................................2  
For indoor use only.  
Operating Environment  
Ambient temperature range ....................0 to 55 °C  
(Tested in accordance with  
IEC-60068-2-1 and  
IEC-60068-2-2. Meets  
MIL-PRF-28800F Class 3  
low temperature limit and  
MIL-PRF-28800F Class 2  
high temperature limit.)  
Relative humidity range..........................10 to 90%, noncondensing  
(Tested in accordance with  
IEC-60068-2-56.)  
Storage Environment  
Ambient temperature range ....................–40 to 71 °C  
(Tested in accordance with  
IEC-60068-2-1 and  
IEC-60068-2-2. Meets  
MIL-PRF-28800F Class 3 limits.)  
Relative humidity range..........................5 to 95%, noncondensing  
(Tested in accordance with  
IEC-60068-2-56.)  
Shock and Vibration  
Operational shock...................................30 g peak, half-sine, 11 ms pulse  
(Tested in accordance with  
IEC-60068-2-27. Meets  
MIL-PRF-28800F Class 2 limits.)  
Random Vibration ..................................5 to 500 Hz, 0.3 grms  
NI PXIe-1065 User Manual  
A-4  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Appendix A  
Specifications  
Acoustic Emissions  
Sound Pressure Level (at Operator Position)  
(Tested in accordance with ISO 7779. Meets MIL-PRF-28800F  
requirements.)  
Auto fan (up to ~30 °C ambient) ........... 45.0 dBA  
High fan.................................................. 63.3 dBA  
Sound Power  
Auto fan (up to ~30 °C ambient) ........... 55.5 dBA  
High fan.................................................. 76.2 dBA  
Note Specifications are subject to change without notice.  
Safety  
This product is designed to meet the requirements of the following  
standards of safety for electrical equipment for measurement, control,  
IEC 61010-1, EN 61010-1  
UL 61010-1, CSA 61010-1  
Note For UL and other safety certifications, refer to the product label or the Online  
Product Certification section.  
Electromagnetic Compatibility  
This product is designed to meet the requirements of the following  
standards of EMC for electrical equipment for measurement, control,  
and laboratory use:  
EN 61326 (IEC 61326): Class A emissions; Basic immunity  
EN 55011 (CISPR 11): Group 1, Class A emissions  
AS/NZS CISPR 11: Group 1, Class A emissions  
FCC 47 CFR Part 15B: Class A emissions  
ICES-001: Class A emissions  
Note For the standards applied to assess the EMC of this product, refer to the Online  
Product Certification section.  
© National Instruments Corporation  
A-5  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Appendix A  
Specifications  
Note For EMC compliance, operate this device with shielded cabling.  
CE Compliance  
This product meets the essential requirements of applicable European  
Directives as follows:  
2006/95/EC; Low-Voltage Directive (safety)  
2004/108/EC; Electromagnetic Compatibility Directive (EMC)  
Online Product Certification  
Refer to the product Declaration of Conformity (DoC) for additional  
regulatory compliance information. To obtain product certifications and the  
DoC for this product, visit ni.com/certification, search by model  
number or product line, and click the appropriate link in the Certification  
column.  
Environmental Management  
National Instruments is committed to designing and manufacturing  
products in an environmentally responsible manner. NI recognizes that  
eliminating certain hazardous substances from our products is beneficial  
not only to the environment but also to NI customers.  
For additional environmental information, refer to the NI and the  
Environment Web page at ni.com/environment. This page contains the  
environmental regulations and directives with which NI complies, as well  
as other environmental information not included in this document.  
Waste Electrical and Electronic Equipment (WEEE)  
EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling  
center. For more information about WEEE recycling centers and National Instruments  
WEEE initiatives, visit ni.com/environment/weee.htm.  
⬉ᄤֵᙃѻક∵ᶧ᥻
ㅵ⧚
⊩ ˄Ё೑  
˅
RoHS  
Ё೑ᅶ᠋  
݇Ѣ  
ヺড়Ё೑⬉ᄤֵᙃѻકЁ䰤
Փ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ  
DŽ
National Instruments  
National Instruments  
(RoHS)  
Ё೑  
ড়㾘ᗻֵᙃˈ䇋ⱏᔩ ni.com/environment/rohs_chinaDŽ  
RoHS  
ni.com/environment/rohs_china  
(For information about China RoHS compliance, go to  
.)  
NI PXIe-1065 User Manual  
A-6  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Appendix A  
Specifications  
Backplane  
Size......................................................... 3U-sized; one system slot  
(with three system expansion  
slots) and 17 peripheral slots.  
Compliant with IEEE 1101.10  
mechanical packaging.  
PXI Express Specification  
compliant.  
Accepts both PXI Express and  
CompactPCI (PICMG 2.0 R 3.0)  
3U modules.  
Backplane bare-board material .............. UL 94 V-0 Recognized  
Backplane connectors ............................ Conforms to IEC 917 and  
IEC 1076-4-101, and are  
UL 94 V-0 rated  
System Synchronization Clocks (PXI_CLK10, PXIe_CLK100,  
PXIe_SYNC100)  
10 MHz System Reference Clock: PXI_CLK10  
Maximum slot-to-slot skew ................... 1 ns  
Accuracy ................................................ 25 ppm max. (guaranteed over  
the operating temperature range)  
Maximum jitter ...................................... 5 ps RMS phase-jitter  
(10 Hz–1 MHz range)  
Duty-factor............................................. 45%–55%  
Unloaded signal swing........................... 3.3 V 0.3 V  
Note For other specifications refer to the PXI-1 Hardware Specification.  
100 MHz System Reference Clock: PXIe_CLK100 and  
PXIe_SYNC100  
Maximum slot-to-slot skew ................... 100 ps  
Accuracy ................................................ 25 ppm max. (guaranteed over  
the operating temperature range)  
© National Instruments Corporation  
A-7  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Appendix A  
Specifications  
Maximum jitter.......................................3 ps RMS phase-jitter  
(10 Hz–12 kHz range)  
2 ps RMS phase-jitter  
(12 kHz–20 MHz range)  
Duty-factor for PXIe_CLK100...............45%–55%  
Absolute single-ended voltage swing  
(When each line in the differential pair  
has 50 W termination to 1.30 V  
or Thévenin equivalent)..........................400–1000 mV  
Note For other specifications refer to the PXI-5 PXI Express Hardware Specification.  
External 10 MHz Reference Out (BNC on rear panel of  
chassis)  
Accuracy................................................. 25 ppm max. (guaranteed over  
the operating temperature range)  
Maximum jitter.......................................5 ps RMS phase-jitter  
(10 Hz–1 MHz range)  
Output amplitude ....................................1 VPP 20% square-wave  
into 50 Ω  
2 VPP unloaded  
Output impedance...................................50 Ω 5 Ω  
External Clock Source  
Frequency ...............................................10 MHz 100 PPM  
Input amplitude  
Rear panel BNC...............................200 mVPP to 5 VPP square-wave  
or sine-wave  
System timing slot  
PXI_CLK10_IN ..............................5 V or 3.3 V TTL signal  
Rear panel BNC input impedance ..........50 Ω 5 Ω  
Maximum jitter introduced  
by backplane...........................................1 ps RMS phase-jitter  
(10 Hz–1 MHz range)  
NI PXIe-1065 User Manual  
A-8  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Appendix A  
Specifications  
PXIe_SYNC_CTRL  
VIH.......................................................... 2.0–5.5 V  
VIL .......................................................... 0–0.8 V  
Maximum slot-to-slot skew ................... 250 ps  
Backplane characteristic impedance ...... 65 Ω 10%  
Note For PXI slot to PXI Star mapping refer to the System Timing Slot section of  
Chapter 1, Getting Started.  
For other specifications refer to the PXI-1 Hardware Specification.  
PXI Differential Star Triggers (PXIe-DSTARA,  
PXIe-DSTARB, PXIe-DSTARC)  
Maximum slot-to-slot skew ................... 150 ps  
Maximum differential skew................... 25 ps  
Backplane differential impedance.......... 100 Ω 10%  
Note For PXIe slot to PXI_DSTAR mapping refer to the System Timing Slot section  
of Chapter 1, Getting Started.  
For other specifications, the NI PXIe-1065 complies with the PXI-5 PXI Express  
Hardware Specification.  
Mechanical  
Overall dimensions  
Standard chassis  
Height ...................................... 6.97 in. (177.1 mm)  
Width ....................................... 18.30 in. (464.8 mm)  
Depth ....................................... 18.40 in. (467.4 mm)  
Note 0.57 in. (14.5 mm) is added to height when feet are installed. When tilted with front  
feet extended on table top, height is increased approximately 2.08 in. (52.8 mm) in front  
and 0.583 in. (14.8 mm) in rear.  
© National Instruments Corporation  
A-9  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Appendix A  
Specifications  
Weight ....................................................12.8 kg (28.2 lb)  
Chassis materials ....................................Sheet Aluminum (5052-H32,  
3003-H14, and 6061-T6),  
Extruded Aluminum (6060-T6),  
and Cold Rolled Steel, PC-ABS,  
Santoprene, Nylon  
Finish ......................................................Conductive Clear Iridite  
on Aluminum  
Electroplated Nickel  
on Cold Rolled Steel  
Polyurethane Enamel  
NI PXIe-1065 User Manual  
A-10  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix A  
Specifications  
Figures A-1 and A-2 show the NI PXIe-1065 chassis dimensions. The  
holes shown are for the installation of the optional rack mount kits. You can  
install those kits on the front or rear of the chassis, depending on which end  
of the chassis you want to face toward the front of the instrument cabinet.  
Notice that the front and rear chassis mounting holes (size M4) are  
symmetrical.  
Dimensions are in inches (millimeters)  
.39  
(9.9)  
17.54 (445.6)  
NI PXIe-1065  
6.97  
(177.1)  
H
1
2
3
4
5
6
7
8
9
10  
11 H  
12 H  
13 H  
14  
15  
16  
17  
18  
0.57  
(14.5)  
1.14  
(29.1)  
1.82  
(46.3)  
1.82  
(46.3)  
1.37  
(34.8)  
1.58  
(40.1)  
10.21 (259.1)  
Front of  
PXI Card  
1.84  
(46.8)  
3.54  
(90.0)  
0.30 (7.25)  
2.12  
(53.8)  
17.11 (434.6)  
3.19  
(81.1)  
Figure A-1. NI PXIe-1065 Chassis Dimensions (Front and Side)  
© National Instruments Corporation  
A-11  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Appendix A  
Specifications  
Dimensions are in inches (millimeters)  
12.700  
(322.58)  
2.524  
(64.11)  
15.504 (393.8)  
1.017  
(25.83)  
Figure A-2. NI PXIe-1065 Chassis Dimensions (Bottom)  
NI PXIe-1065 User Manual  
A-12  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Appendix A  
Specifications  
Figure A-3 shows the chassis rack mount kit components.  
2
NI  
PXI  
e-106  
5
3
1
1
Front Rack Mount Kit  
2
NI Chassis  
3
Optional Rear Rack Mount Kit  
Figure A-3. NI Chassis Rack Mount Kit Components  
Note The chassis shown in Figure A-3 is representative of the NI PXI-1044/1045 and  
NI PXIe-1065 product line.  
© National Instruments Corporation  
A-13  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
B
Pinouts  
This appendix describes the connector pinouts for the NI PXIe-1065  
chassis backplane.  
Table B-1 shows the XP1 connector pinout for the System Controller slot.  
Table B-2 shows the XP2 Connector Pinout for the System Controller slot.  
Table B-3 shows the XP3 Connector Pinout for the System Controller slot.  
Table B-4 shows the XP4 Connector Pinout for the System Controller slot.  
Table B-5 shows the TP1 Connector Pinout for the System Controller slot.  
Table B-6 shows the TP2 Connector Pinout for the System Timing slot.  
Table B-7 shows the XP3 Connector Pinout for the System Timing slot.  
Table B-8 shows the XP4 Connector Pinout for the System Timing slot.  
Table B-9 shows the P1 connector pinout for the peripheral slots.  
Table B-10 shows the P2 connector pinout for the peripheral slots.  
Table B-11 shows the P1 connector pinout for the Hybrid peripheral slots.  
Table B-12 shows the XP3 Connector Pinout for the Hybrid  
peripheral slots.  
Table B-13 shows the XP4 Connector Pinout for the Hybrid  
peripheral slots.  
For more detailed information, refer to the PXI-5 PXI Express Hardware  
Specification, Revision 2.0. Contact the PXI Systems Alliance for a copy  
of the specification.  
© National Instruments Corporation  
B-1  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Appendix B  
Pinouts  
System Controller Slot Pinouts  
Table B-1. XP1 Connector Pinout for the System Controller Slot  
Pins  
A
Signals  
GND  
12V  
B
C
12V  
D
GND  
5V  
E
F
3.3V  
GND  
G
Table B-2. XP2 Connector Pinout for the System Controller Slot  
Pin  
A
B
ab  
C
D
cd  
E
F
ef  
1
2
3
4
5
6
7
8
9
3PETp1  
3PETn1  
GND  
3PERp1  
3PERn1  
GND  
3PETp2  
3PETn2  
3PERn2  
4PETn1  
4PERn1  
RSV  
GND  
3PETp3  
4PETp0  
4PETp2  
4PETp3  
RSV  
3PETn3  
4PETn0  
4PETn2  
4PETn3  
RSV  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
3PERp3  
4PERp0  
4PERp2  
4PERp3  
RSV  
3PERn3  
4PERn0  
4PERn2  
4PERn3  
RSV  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
3PERp2  
4PETp1  
4PERp1  
RSV  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
RSV  
RSV  
RSV  
RSV  
RSV  
RSV  
RSV  
RSV  
RSV  
RSV  
RSV  
RSV  
RSV  
RSV  
RSV  
RSV  
RSV  
RSV  
RSV  
RSV  
10  
RSV  
RSV  
RSV  
RSV  
RSV  
RSV  
Table B-3. XP3 Connector Pinout for the System Controller Slot  
Pin  
A
B
ab  
C
D
cd  
E
F
ef  
1
2
3
4
5
6
RSV  
RSV  
RSV  
GND  
RSV  
RSV  
GND  
RSV  
RSV  
GND  
GND  
GND  
GND  
GND  
GND  
RSV  
GND  
GND  
GND  
GND  
GND  
PWR_OK  
4RefClk+  
3RefClk+  
1PERp0  
PS_ON#  
4RefClk–  
3RefClk–  
1PERn0  
1PERn2  
GND  
GND  
GND  
GND  
GND  
LINKCAP  
2RefClk+  
1RefClk+  
1PETp1  
PWRBTN#  
2RefClk–  
1RefClk–  
1PETn1  
1PERn1  
SMBDAT  
RSV  
SMBCLK  
PERST#  
1PETn0  
1PETn2  
1PETp0  
1PETp2  
1PERp2  
1PERp1  
NI PXIe-1065 User Manual  
B-2  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Appendix B  
Pinouts  
Table B-3. XP3 Connector Pinout for the System Controller Slot (Continued)  
Pin  
A
B
ab  
C
D
cd  
E
F
ef  
7
8
9
1PETp3  
1PETn3  
GND  
1PERp3  
1PERn3  
GND  
2PETp0  
2PETn0  
GND  
2PETp1  
2PETp2  
3PETp0  
2PETn1  
2PETn2  
3PETn0  
GND  
GND  
GND  
2PERp1  
2PERp2  
3PERp0  
2PERn1  
2PERn2  
3PERn0  
GND  
GND  
GND  
2PERp0  
2PETp3  
2PERp3  
2PERn0  
2PETn3  
2PERn3  
GND  
GND  
GND  
10  
Table B-4. XP4 Connector Pinout for the System Controller Slot  
Pin  
Z
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
A
B
C
D
E
F
1
2
3
4
5
6
7
8
GA4  
5Vaux  
RSV  
RSV  
GA3  
GND  
RSV  
RSV  
GA2  
GA1  
GA0  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
SYSEN#  
RSV  
WAKE#  
RSV  
ALERT#  
RSV  
RSV  
RSV  
RSV  
PXI_TRIG3  
PXI_TRIG2  
PXI_TRIG1  
RSV  
PXI_TRIG4  
GND  
PXI_TRIG5  
RSV  
GND  
PXI_TRIG6  
PXI_CLK10  
PXI_TRIG7  
PXI_LBR6  
PXI_STAR  
GND  
PXI_TRIG0  
GND  
RSV  
RSV  
RSV  
System Timing Slot Pinouts  
Table B-5. TP1 Connector Pinout for the System Timing Slot  
Pin  
A
B
ab  
C
D
cd  
E
F
ef  
1
PXIe_DSTARA3+  
PXIe_DSTARC4+  
PXIe_DSTARB4+  
PXIe_DSTARA4+  
PXIe_DSTARC5+  
PXIe_DSTARB5+  
PXIe_DSTARA5+  
PXIe_DSTARC6+  
PXIe_DSTARB6+  
PXIe_DSTARA6+  
PXIe_DSTARA3–  
PXIe_DSTARC4–  
PXIe_DSTARB4–  
PXIe_DSTARA4–  
PXIe_DSTARC5–  
PXIe_DSTARB5–  
PXIe_DSTARA5–  
PXIe_DSTARC6–  
PXIe_DSTARB6–  
PXIe_DSTARA6–  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
NC  
NC  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
2
PXI_STAR12  
PXI_STAR13  
3
NC  
NC  
4
NC  
NC  
5
PXI_STAR14  
PXI_STAR15  
6
NC  
NC  
NC  
RSV  
NC  
NC  
7
NC  
8
PXI_STAR16  
9
NC  
NC  
10  
© National Instruments Corporation  
B-3  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Appendix B  
Pinouts  
Table B-6. TP2 Connector Pinout for the System Timing Slot  
Pin  
A
B
ab  
C
PXIe_DSTARC8+  
NC  
D
PXIe_DSTARC8–  
NC  
cd  
E
F
ef  
1
NC  
NC  
NC  
NC  
NC  
NC  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
PXIe_DSTARB8+  
PXIe_DSTARB8–  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
2
PXIe_DSTARA8+  
PXIe_DSTARA8–  
3
PXIe_DSTARC1+  
PXI_STAR0  
PXI_STAR2  
PXI_STAR4  
PXI_STAR6  
PXI_STAR8  
PXI_STAR10  
NC  
PXIe_DSTARC1–  
PXI_STAR1  
PXI_STAR3  
PXI_STAR5  
PXI_STAR7  
PXI_STAR9  
PXI_STAR11  
NC  
NC  
NC  
4
PXIe_DSTARB1+  
PXIe_DSTARA1+  
PXIe_DSTARC2+  
PXIe_DSTARB2+  
PXIe_DSTARA2+  
PXIe_DSTARC3+  
PXIe_DSTARB3+  
PXIe_DSTARB1–  
PXIe_DSTARA1–  
PXIe_DSTARC2–  
PXIe_DSTARB2–  
PXIe_DSTARA2–  
PXIe_DSTARC3–  
PXIe_DSTARB3–  
NC  
NC  
5
NC  
NC  
6
NC  
NC  
7
NC  
NC  
8
PXIe_DSTARC11+  
PXIe_DSTARA11+  
PXIe_DSTARB11+  
PXIe_DSTARC11–  
PXIe_DSTARA11–  
PXIe_DSTARB11–  
9
10  
Table B-7. XP3 Connector Pinout for the System Timing Slot  
Pin  
A
PXIe_CLK100+  
PRSNT#  
SMBDAT  
MPWRGD*  
1PETp0  
B
PXIe_CLK100–  
PWREN#  
SMBCLK  
PERST#  
1PETn0  
ab  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
C
PXIe_SYNC100+  
PXIe_DSTARB+  
RSV  
D
PXIe_SYNC100–  
PXIe_DSTARB–  
RSV  
cd  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
E
PXIe_DSTARC+  
PXIe_DSTARA+  
RSV  
F
PXIe_DSTARC–  
PXIe_DSTARA–  
RSV  
ef  
1
GND  
2
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
3
4
RSV  
RSV  
1RefClk+  
1PETp1  
1RefClk–  
1PETn1  
5
1PERp0  
1PERn0  
6
1PETp2  
1PETn2  
1PERp2  
1PERn2  
1PERp1  
1PERn1  
7
1PETp3  
1PETn3  
1PERp3  
1PERn3  
1PETp4  
1PETn4  
8
1PETp5  
1PETn5  
1PERp5  
1PERn5  
1PERp4  
1PERn4  
9
1PETp6  
1PETn6  
1PERp6  
1PERn6  
1PETp7  
1PETn7  
10  
RSV  
RSV  
RSV  
RSV  
1PERp7  
1PERn7  
Table B-8. XP4 Connector Pinout for the System Timing Slot  
Pin  
Z
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
A
B
C
D
E
F
1
2
3
4
5
6
7
8
GA4  
5Vaux  
12V  
GA3  
GND  
12V  
GA2  
GA1  
GA0  
GND  
SYSEN#  
GND  
WAKE#  
GND  
3.3V  
ALERT#  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
3.3V  
3.3V  
PXI_TRIG3  
PXI_TRIG4  
GND  
PXI_TRIG5  
ATNLED  
ATNSW#  
RSV  
GND  
PXI_TRIG6  
PXI_CLK10  
PXI_TRIG7  
PXI_LBR6  
PXI_TRIG2  
PXI_CLK10_IN  
GND  
PXI_TRIG1  
PXI_TRIG0  
GND  
PXIe_SYNC_CTRL  
PXI_LBL6  
NI PXIe-1065 User Manual  
B-4  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
Appendix B  
Pinouts  
Peripheral Slot Pinouts  
Table B-9. P1 Connector Pinout for the Peripheral Slot  
Pin  
25  
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
12–14  
11  
10  
9
Z
A
B
C
D
E
F
GND  
5V  
REQ64#  
5V  
ENUM#  
V(I/O)  
AD[3]  
3.3V  
3.3V  
5V  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
AD[1]  
3.3V  
AD[0]  
5V  
ACK64#  
AD[2]  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
AD[4]  
GND  
AD[7]  
3.3V  
AD[6]  
M66EN  
AD[11]  
GND  
AD[5]  
AD[9]  
GND  
AD[8]  
V(I/O)  
AD[14]  
3.3V  
C/BE[0]#  
AD[10]  
AD[13]  
C/BE[1]#  
PERR#  
LOCK#  
TRDY#  
AD[12]  
3.3V  
AD[15]  
GND  
SERR#  
3.3V  
PAR  
IPMB_SCL  
GND  
IPMB_SDA  
V(I/O)  
GND  
DEVSEL#  
3.3V  
STOP#  
BD_SEL#  
FRAME#  
IRDY#  
Key Area  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
AD[18]  
AD[21]  
C/BE[3]#  
AD[26]  
AD[30]  
REQ#  
AD[17]  
GND  
AD[16]  
3.3V  
GND  
AD[20]  
GND  
AD[25]  
GND  
CLK  
C/BE[2]#  
AD[19]  
AD[22]  
AD[24]  
AD[27]  
AD[31]  
GNT#  
INTS  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
IDSEL  
GND  
AD[23]  
V(I/O)  
AD[28]  
3.3V  
8
7
AD[29]  
GND  
6
5
BRSVP1A5  
IPMB_PWR  
INTA#  
BRSVP1B5  
HEALTHY  
INTB#  
5V  
RST#  
GND  
INTP  
5V  
4
V(I/O)  
INTC#  
TMS  
3
INTD#  
TDI  
2
TCK  
TDO  
+12V  
1
5V  
–12V  
TRST#  
5V  
© National Instruments Corporation  
B-5  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Appendix B  
Pinouts  
Table B-10. P2 Connector Pinout for the Peripheral Slot  
Pin  
Z
A
B
C
D
E
F
22  
21  
20  
19  
18  
17  
16  
15  
14  
13  
12  
11  
10  
9
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GA4  
GA3  
GA2  
GA1  
GA0  
GND  
PXI_LBR0  
GND  
PXI_LBR1  
PXI_LBL0  
PXI_LBL3  
PXI_TRIG5  
RSV  
PXI_LBR2  
GND  
PXI_LBR3  
PXI_LBL1  
PXI_LBL5  
PXI_TRIG6  
PXI_CLK10  
PXI_TRIG7  
PXI_LBR6  
RSV  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
PXI_LBR4  
PXI_LBL2  
PXI_TRIG3  
PXI_TRIG2  
PXI_TRIG1  
PXI_LBR5  
GND  
PXI_LBL4  
GND  
PXI_TRIG4  
GND  
PXI_STAR  
GND  
PXI_TRIG0  
GND  
RSV  
PXI_BRSVA15  
RSV  
RSV  
PXI_LBL6  
GND  
RSV  
RSV  
RSV  
GND  
V(I/O)  
RSV  
RSV  
RSV  
RSV  
RSV  
GND  
RSV  
RSV  
GND  
V(I/O)  
RSV  
RSV  
RSV  
RSV  
RSV  
GND  
RSV  
RSV  
GND  
V(I/O)  
RSV  
RSV  
RSV  
8
RSV  
RSV  
GND  
RSV  
7
RSV  
GND  
V(I/O)  
RSV  
RSV  
RSV  
6
RSV  
RSV  
GND  
RSV  
5
RSV  
GND  
V(I/O)  
RSV  
RSV  
RSV  
4
V(I/O)  
PXI_LBR7  
PXI_LBR11  
PXI_LBL9  
64EN#  
GND  
GND  
RSV  
3
PXI_LBR8  
UNC  
PXI_LBR9  
PXI_LBL7  
PXI_LBL11  
PXI_LBR10  
PXI_LBL8  
PXI_LBL12  
2
PXI_LBR12  
GND  
1
PXI_LBL10  
NI PXIe-1065 User Manual  
B-6  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Appendix B  
Pinouts  
Hybrid Slot Pinouts  
Table B-11. P1 Connector Pinout for the Hybrid Slot  
Pin  
25  
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
12–14  
11  
10  
9
Z
A
B
C
D
E
F
GND  
5V  
REQ64#  
5V  
ENUM#  
V(I/O)  
AD[3]  
3.3V  
3.3V  
5V  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
AD[1]  
3.3V  
AD[0]  
5V  
ACK64#  
AD[2]  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
AD[4]  
GND  
AD[7]  
3.3V  
AD[6]  
M66EN  
AD[11]  
GND  
AD[5]  
AD[9]  
GND  
AD[8]  
V(I/O)  
AD[14]  
3.3V  
C/BE[0]#  
AD[10]  
AD[13]  
C/BE[1]#  
PERR#  
LOCK#  
TRDY#  
AD[12]  
3.3V  
AD[15]  
GND  
SERR#  
3.3V  
PAR  
IPMB_SCL  
GND  
IPMB_SDA  
V(I/O)  
GND  
DEVSEL#  
3.3V  
STOP#  
BD_SEL#  
FRAME#  
IRDY#  
Key Area  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
AD[18]  
AD[21]  
C/BE[3]#  
AD[26]  
AD[30]  
REQ#  
AD[17]  
GND  
AD[16]  
3.3V  
GND  
AD[20]  
GND  
AD[25]  
GND  
CLK  
C/BE[2]#  
AD[19]  
AD[22]  
AD[24]  
AD[27]  
AD[31]  
GNT#  
INTS  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
IDSEL  
GND  
AD[23]  
V(I/O)  
AD[28]  
3.3V  
8
7
AD[29]  
GND  
6
5
BRSVP1A5  
IPMB_PWR  
INTA#  
BRSVP1B5  
HEALTHY#  
INTB#  
5V  
RST#  
GND  
INTP  
5V  
4
V(I/O)  
INTC#  
TMS  
3
INTD#  
TDI  
2
TCK  
TDO  
+12V  
1
5V  
–12V  
TRST#  
5V  
© National Instruments Corporation  
B-7  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Appendix B  
Pinouts  
Table B-12. XP3 Connector Pinout for the Hybrid Slot  
Pin  
A
B
PXIe_CLK100–  
PWREN#  
SMBCLK  
PERST#  
1PETn0  
ab  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
C
PXIe_SYNC100+  
PXIe_DSTARB+  
RSV  
D
PXIe_SYNC100–  
PXIe_DSTARB–  
RSV  
cd  
E
PXIe_DSTARC+  
PXIe_DSTARA+  
RSV  
F
PXIe_DSTARC–  
PXIe_DSTARA–  
RSV  
ef  
1
PXIe_CLK100+  
PRSNT#  
SMBDAT  
MPWRGD*  
1PETp0  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
2
3
4
RSV  
RSV  
1RefClk+  
1PETp1  
1RefClk-  
1PETn1  
5
1PERp0  
1PERn0  
6
1PETp2  
1PETn2  
1PERp2  
1PERn2  
1PERp1  
1PERn1  
7
1PETp3  
1PETn3  
1PERp3  
1PERn3  
1PETp4  
1PETn4  
8
1PETp5  
1PETn5  
1PERp5  
1PERn5  
1PERp4  
1PERn4  
9
1PETp6  
1PETn6  
1PERp6  
1PERn6  
1PETp7  
1PETn7  
10  
RSV  
RSV  
RSV  
RSV  
1PERp7  
1PERn7  
Table B-13. XP4 Connector Pinout for the Hybrid Slot  
Pin  
Z
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
A
B
C
D
E
F
1
2
3
4
5
6
7
8
GA4  
5Vaux  
12V  
GA3  
GND  
12V  
GA2  
GA1  
GA0  
GND  
SYSEN#  
GND  
WAKE#  
GND  
3.3V  
ALERT#  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
GND  
3.3V  
3.3V  
PXI_TRIG3  
PXI_TRIG2  
PXI_TRIG1  
RSV  
PXI_TRIG4  
GND  
PXI_TRIG5  
ATNLED  
ATNSW#  
RSV  
GND  
PXI_TRIG6  
PXI_CLK10  
PXI_TRIG7  
PXI_LBR6  
PXI_STAR  
GND  
PXI_TRIG0  
GND  
PXI_LBL6  
NI PXIe-1065 User Manual  
B-8  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
C
Technical Support and  
Professional Services  
Visit the following sections of the award-winning National Instruments  
Web site at ni.com for technical support and professional services:  
Support—Technical support at ni.com/support includes the  
following resources:  
Self-Help Technical Resources—For answers and solutions,  
visit ni.com/support for software drivers and updates,  
a searchable KnowledgeBase, product manuals, step-by-step  
troubleshooting wizards, thousands of example programs,  
tutorials, application notes, instrument drivers, and so on.  
Registered users also receive access to the NI Discussion Forums  
at ni.com/forums. NI Applications Engineers make sure every  
question submitted online receives an answer.  
Standard Service Program Membership—This program  
entitles members to direct access to NI Applications Engineers  
via phone and email for one-to-one technical support as well as  
exclusive access to on demand training modules via the Services  
Resource Center. NI offers complementary membership for a full  
year after purchase, after which you may renew to continue your  
benefits.  
For information about other technical support options in your  
area, visit ni.com/services, or contact your local office at  
ni.com/contact.  
Training and Certification—Visit ni.com/training for  
self-paced training, eLearning virtual classrooms, interactive CDs,  
and Certification program information. You also can register for  
instructor-led, hands-on courses at locations around the world.  
System Integration—If you have time constraints, limited in-house  
technical resources, or other project challenges, National Instruments  
Alliance Partner members can help. To learn more, call your local  
NI office or visit ni.com/alliance.  
© National Instruments Corporation  
C-1  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                   
Appendix C  
Technical Support and Professional Services  
Declaration of Conformity (DoC)—A DoC is our claim of  
compliance with the Council of the European Communities using  
the manufacturer’s declaration of conformity. This system affords  
the user protection for electromagnetic compatibility (EMC) and  
product safety. You can obtain the DoC for your product by visiting  
ni.com/certification.  
If you searched ni.com and could not find the answers you need, contact  
your local office or NI corporate headquarters. Phone numbers for our  
worldwide offices are listed at the front of this manual. You also can visit  
the Worldwide Offices section of ni.com/niglobal to access the branch  
office Web sites, which provide up-to-date contact information, support  
phone numbers, email addresses, and current events.  
NI PXIe-1065 User Manual  
C-2  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Glossary  
Symbol  
Prefix  
pico  
Value  
10–12  
10–9  
10– 6  
10–3  
103  
p
n
nano  
micro  
milli  
kilo  
μ
m
k
M
G
T
mega  
giga  
106  
109  
tera  
1012  
Symbols  
°
Degrees.  
%
Equal or greater than.  
Equal or less than.  
Percent.  
A
A
Amperes.  
AC  
Alternating current.  
ANSI  
Auto  
AWG  
American National Standards Institute.  
Automatic fan speed control.  
American Wire Gauge.  
© National Instruments Corporation  
G-1  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Glossary  
B
backplane  
An assembly, typically a printed circuit board, with connectors and signal  
paths that bus the connector pins.  
BNC  
Bayonet Neill Concelman connector; a commonly used coaxial connector.  
C
C
Celsius.  
cfm  
Cubic feet per minute.  
Code of Federal Regulations.  
Centimeters.  
CFR  
cm  
CompactPCI  
An adaptation of the Peripheral Component Interconnect (PCI)  
Specification 2.1 or later for industrial and/or embedded applications  
requiring a more robust mechanical form factor than desktop PCI. It  
uses industry standard mechanical components and high-performance  
connector technologies to provide an optimized system intended for rugged  
applications. It is electrically compatible with the PCI Specification, which  
enables low-cost PCI components to be utilized in a mechanical form factor  
suited for rugged environments.  
CSA  
Canadian Standards Association.  
D
daisy-chain  
A method of propagating signals along a bus, in which the devices are  
prioritized on the basis of their position on the bus.  
DB-9  
DC  
A 9-pin D-SUB connector.  
Direct current.  
DoC  
Declaration of Conformity.  
Subminiature D connector.  
D-SUB  
NI PXIe-1065 User Manual  
G-2  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Glossary  
E
efficiency  
Ratio of output power to input power, expressed as a percentage.  
Electronic Industries Association.  
EIA  
EMC  
EMI  
Electromagnetic Compatibility.  
Electromagnetic Interference.  
F
FCC  
Federal Communications Commission.  
filler panel  
A blank module front panel used to fill empty slots in the chassis.  
G
g
(1) grams; (2) a measure of acceleration equal to 9.8 m/s2.  
General Purpose Interface Bus (IEEE 488).  
GPIB  
gRMS  
A measure of random vibration. The root mean square of acceleration  
levels in a random vibration test profile.  
H
hr  
Hours.  
Hz  
Hertz; cycles per second.  
I
IEC  
International Electrotechnical Commission; an organization that sets  
international electrical and electronics standards.  
IEEE  
IMP  
Institute of Electrical and Electronics Engineers.  
Mainframe peak current.  
© National Instruments Corporation  
G-3  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Glossary  
in.  
Inches.  
inhibit  
To turn off.  
J
jitter  
A measure of the small, rapid variations in clock transition times from their  
nominal regular intervals. Units: seconds RMS.  
K
kg  
Kilograms.  
Kilometers.  
km  
L
lb  
Pounds.  
LED  
Light emitting diode.  
line regulation  
The maximum steady-state percentage that a DC voltage output will  
change as a result of a specified change in input AC voltage (step change  
from 90 to 132 VAC or 180 to 264 VAC).  
load regulation  
The maximum steady-state percentage that a DC voltage output will  
change as a result of a step change from no-load to full-load output current.  
M
m
Meters.  
MHz  
mi  
Megahertz. One million Hertz; one Hertz equals one cycle per second.  
Miles.  
ms  
Milliseconds.  
MTBF  
MTTR  
Mean time to repair.  
NI PXIe-1065 User Manual  
G-4  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Glossary  
N
NEMA  
National Electrical Manufacturers Association.  
National Instruments.  
NI  
P
power supply shuttle  
A removable module that contains the chassis power supply.  
PCI eXtensions for Instrumentation.  
PXI  
PXI_CLK10  
10 MHz PXI system reference clock.  
R
RH  
Relative humidity.  
Root mean square.  
RMS  
S
s
Seconds.  
skew  
Deviation in signal transmission times.  
slot blocker  
An assembly installed into an empty slot to improve the airflow in adjacent  
slots.  
standby  
The backplane is unpowered (off), but the chassis is still connected to AC  
power mains.  
System controller  
A module configured for installation in Slot 1of a PXI chassis. This device  
is unique in the PXI system in that it performs the system controller  
functions, including clock sourcing and arbitration for data transfers across  
the backplane. Installing such a device into any other slot can damage the  
device, the PXI backplane, or both.  
© National Instruments Corporation  
G-5  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Glossary  
system reference  
clock  
A 10 MHz clock, also called PXI_CLK10, that is distributed to all  
peripheral slots in the chassis, as well as a BNC connector on the rear of  
chassis labeled 10 MHz REF OUT. The system reference clock can be used  
for synchronization of multiple modules in a measurement or control  
system. The 10 MHz REF IN and OUT BNC connectors on the rear of the  
chassis can be used to synchronize multiple chassis to one reference clock.  
The PXI backplane specification defines implementation guidelines for  
PXI_CLK10.  
System Timing slot  
This slot is located at slot 4 and has dedicated trigger lines to other slots.  
T
TTL  
Transistor-transistor logic.  
U
UL  
Underwriter’s Laboratories.  
V
V
Volts.  
VAC  
Vpp  
Volts alternating current.  
Peak-to-peak voltage.  
W
W
Watts.  
NI PXIe-1065 User Manual  
G-6  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
CompactPCI  
A
and operation  
connector pinouts. See pinouts  
conventions used in the manual, vii  
B
backplane  
hybrid peripheral slots, 1-7  
interoperability with CompactPCI, 1-6  
overview, 1-6  
PXI Express peripheral slots, 1-8  
PXI local bus, routing, 1-9  
PXI peripheral slots, 1-7  
PXIe_SYNC_CTRL, 1-14  
specifications, A-7  
air cooling of PXIe-1065 chassis, 2-2  
filler panel installation, 2-5  
system controller slot, 1-6  
system reference clock, 1-11  
default behavior (figure), 1-12  
D
DB-9 connector  
pinout (table), 2-10  
power supply voltages (table), 2-11  
Declaration of Conformity (NI resources), C-2  
diagnostic tools (NI resources), C-1  
dimensions (figure), A-11, A-12  
documentation  
C
conventions used in manual, vii  
cables, power (table), 1-2  
CE compliance, specifications, A-6  
chassis ambient temperature definitions, 2-4  
chassis cooling considerations  
ambient temperature definitions, 2-4  
clearances, 2-2  
figure, 2-3  
vents (figure), 2-4  
electromagnetic compatibility, A-5  
EMC filler panel kit, 1-5  
environmental management, specifications, A-6  
WEEE information, A-6  
examples (NI resources), C-1  
external clock source specifications, A-8  
chassis initialization file, 2-16  
chassis ventilation (figure), 2-4  
clearances for chassis cooling, 2-2  
figure, 2-3  
CLK10 rear connectors, 2-12  
© National Instruments Corporation  
I-1  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Index  
testing power up, 2-6  
F
fan, setting speed, 2-5  
filler panel installation, 2-5  
unpacking the PXIe-1065, 1-1  
installing a PXI Express system controller  
G
ground, connecting, 2-5  
H
help, technical support, C-1  
hybrid peripheral slots, description, 1-7  
hybrid slot pinouts  
K
kit contents, 1-1  
XP4 connector (table), B-8  
I
IEC 320 inlet, 1-5, 2-6  
inhibit mode switch, 2-12  
configuration in MAX (figure), 2-13  
connecting safety ground, 2-5  
M
cleaning  
interior cleaning, 3-1  
preparation, 3-1  
resetting the AC mains circuit  
breaker, 3-2  
module installation  
static discharge damage (caution), 3-1  
figure, 2-9  
services, C-1  
PXI Express system controller installed in  
a NI PXIe-1065 chassis (figure), 2-8  
rack mounting, 2-5  
NI PXIe-1065  
fan speed, setting, 2-5  
front view (figure), 1-4  
installation. See installation,  
configuration, and operation  
remote voltage monitoring and inhibiting  
interface, 2-10  
NI PXIe-1065 User Manual  
I-2  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
key features, 1-2  
NI PXIe-1065 chassis  
optional equipment, 1-5  
rack mounting, 2-5  
interface, 2-10  
replacing, 3-3  
rear view of NI PXIe-1065 chassis, 1-5  
safety ground, connecting, 2-5  
unpacking, 1-1  
installation, 3-3  
NI PXIe-1065 backplane  
hybrid peripheral slots, 1-7  
interoperability with CompactPCI, 1-6  
overview, 1-6  
voltages at voltage monitoring connector  
PXI Express peripheral slots, 1-8  
PXI local bus, routing, 1-9  
PXI peripheral slots, 1-7  
PXIe_SYNC_CTRL, 1-14  
using as restart (figure), 1-14  
specifications, A-7  
system controller slot, 1-6  
system reference clock, 1-11  
default behavior (figure), 1-12  
routing (figure), 1-12  
(PXIe-DSTARA, PXIe-DSTARB,  
(figure), 2-8  
PXI local bus, routing, 1-9  
PXI peripheral slots, description, 1-7  
PXI star trigger specifications, A-9  
PXI star, routing, 1-9  
trigger bus, 1-10  
NI support and services, C-1  
O
PXI-1 configuration in MAX, 2-13  
PXIe_DSTAR, routing, 1-9  
optional equipment, 1-5  
P
peripheral module installation, 2-8  
figure, 2-9  
peripheral slot pinouts  
rack mount kit dimensions (figure), A-13  
rack mounting, 2-5  
P1 connector (table), B-5  
P2 connector (table), B-6  
pinouts, B-1  
kit, 1-5  
recycling hardware, A-6  
related documentation, viii  
DB-9 connector (table), 2-10  
power cables (table), 1-2  
power inhibit switch LED indicator, 2-10  
© National Instruments Corporation  
I-3  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
PXIe-DSTARC), A-9  
S
PXI star trigger, A-9  
safety and caution notices, 2-1  
safety ground, connecting, 2-5  
safety, specifications, A-5  
service interval, 3-1  
setting fan speed, 2-5  
slot blocker  
PXIe_SYNC_CTRL, A-9  
rack mount kit dimensions (figure), A-13  
safety, A-5  
shock and vibration, A-4  
system reference clocks, A-7  
static discharge damage (caution), 3-1  
support, technical, C-1  
installation, 2-5  
kit, 1-6  
software (NI resources), C-1  
specifications  
description, 1-6  
pinouts  
XP1 connector (table), B-2  
XP2 connector (table), B-2  
XP3 connector (table), B-2  
XP4 connector (table), B-3  
system reference clock, 1-11  
default behavior (figure), 1-12  
routing (figure), 1-12  
sound pressure level (at operator  
backplane  
100 MHz system reference clock  
specifications, A-7  
system timing slot  
description, 1-8  
pinouts  
PXIe_SYNC100), A-7  
CE compliance, A-6  
chassis cooling, A-3  
dimensions (figure), A-11, A-12  
electrical  
TP1 connector (table), B-3  
AC input, A-1  
DC output, A-2  
electromagnetic compatibility, A-5  
environmental  
technical support, C-1  
operating environment, A-4  
storage environment, A-4  
environmental management, A-6  
WEEE information, A-6  
external clock source, A-8  
testing power up, 2-6  
training and certification (NI resources), C-1  
trigger bus, 1-10  
troubleshooting (NI resources), C-1  
NI PXIe-1065 User Manual  
I-4  
ni.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
U
unpacking the NI PXIe-1065 chassis, 1-1  
Web resources, C-1  
WEEE information, A-6  
V
voltage monitoring connector. See DB-9  
connector  
voltages at voltage monitoring connector  
(DB-9) (table), 2-11  
© National Instruments Corporation  
I-5  
NI PXIe-1065 User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Milan Technology Switch MIL S801XX User Manual
Milwaukee Power Hammer 5303 20 User Manual
Muse electronic DVD Player Model Eleven User Manual
Net Optics Network Card Link Aggregator Tap 10 100 In Line to GigaBit with SFP Monitor Ports User Manual
Numark Industries Musical Instrument DM 950 User Manual
Olympus Printer P 400ID User Manual
Omega Vehicle Security Switch CN3271 Series User Manual
Palsonic CRT Television 8110Y User Manual
Panasonic Laptop CF C1 User Manual
Paradyne Network Card ENE2020 P User Manual