| A88-8916N   Revised 01-97   Section 40   (00-02-0196)   ® AUTOMATIC ENGINE CONTROLLERS   MODELS A88 AND A88-F   INSTALLATION MANUAL   Download from Www.Somanuals.com. All Manuals Search And Download.   WARNING   BEFORE BEGINNING   INSTALLATION OF THIS   MURPHY PRODUCT   ✔ Disconnect all electrical   power to the machine.   ✔ Make sure the machine   cannot operate during   installation.   ✔ Follow all safety warnings of   the machine manufacturer.   ✔ Read and follow all   installation instructions.   Download from Www.Somanuals.com. All Manuals Search And Download.   SECTION I: INTRODUCTION   A. The Automatic Engine Controller, Model A88 and   8. Crank disconnect circuitry accepts the following inputs:   a. breaker or electronic type ignition   b. magnetic pickup   A88-F is designed to automatically start, monitor and stop   electric start engines. The A88 comes in an all-weather   case with a 5 foot cable and a plug for connection. The   A88-F is the same system, but housed in a panel-mount   case with terminals on back for connecting.   c. alternator tach   d. flywheel alternator   e. mechanical switch   9. Has a built-in one minute time delay for customer use.   10. Five fixed crank attempts before shutdown.   B. Features   1. Has a self-contained Auto-Off-Test Switch.   2. Rest and crank time selected by a single switch.   3. Adjustable crank disconnect speed switch.   4. Close a switch to run; open to stop feature.   5. Engine starts and runs when a contact closes and   stops when a separate set of contacts close.   6. Goes into a rest period in the event of a false start.   7. Alarm before start to alert personnel.   SECTION II: SPECIFICATIONS   A. Power Requirements:   11. An output to indicate that the engine is running   to be used as remote indication or in warm up   operation.   1. Voltage 8-30 VDC, negative ground.   2. Current @ 12 volts less load current.   a. standby   b. crank   c. shutdown 32 ma   10 ma   140 ma   12. Has a summary of shutdown output.   13. Monitors the following engine functions and will   shut the engine down in event of a failure:   a. Overcrank   3. Maximum fuse size, 4 amp, slow blow.   b. Oil Pressure   c. Engine Temperature   d. Spare   B. Input Requirements:   1. Start-stop control switch   a. SPST N.O. dry contact; close to run, open to stop   b. SPDT dry contact   14. Has 30 second lockout feature for start up.   15. Output for choke actuator.   c. Two SPST N.O. dry contacts; one, momentary   close to run; one momentary close to stop   2. Magnetic pickup or alternator tach requirements:   a. voltage 2 volts, rms minimum   b. 25 to 2000 hz crank disconnect   c. maximum 100 volts Pk Pk   C. Output Ratings: Source = switch to battery   Sink = switch to ground   1. Ignition or run relay; SPDT dry relay contacts   rated 10 amp @ 30 VDC resistive, 6 amp @ 30   VDC inductive.   2. Crank output   a. transistor   b. transistor   1 amp source   1 amp sink   3. Choke   a. transistor   4. Time delay   a. transistor   5. Summary   a. transistor   1 amp sink   1 amp sink   1/2 amp sink   1 Download from Www.Somanuals.com. All Manuals Search And Download.   SECTION III: FRONT PANEL DESCRIPTION   IGNITION   A88   CHOKE   ON   PICK UP   PRESENT   OVER   CRANK   Automatic   Engine   Controller   OIL   CRANK   PRESSURE   CRANK   DISCONNECT   ENGINE   TEMP.   CRANK   DISCONNECT   (Shown without enclosure)   5s   AUTO   OFF   CRANK   10s   AND   REST   TIME   15s   TEST   20s   IGNITION   CHOKE   ON   PICK UP   PRESENT   OVER   CRANK   OIL   PRESSURE   CRANK   A88-F   CRANK   DISCONNECT   ENGINE   TEMP.   Automatic   Engine   CRANK   DISCONNECT   AUTO   OFF   TEST   Controller   (Shown without enclosure)   5s   CRANK   10s   AND   REST   TIME   15s   20s   2 Download from Www.Somanuals.com. All Manuals Search And Download.   FRONT PANEL DESCRIPTION   9. SPARE   Along with each description, an attempt has been made This LED comes on to indicate cause of shutdown if the   to clarify output and input connections according to their spare is used. Connect the monitor to Terminal 13 of the   functions and terminals or wire color.   A88-F and the yellow/white wire of the A88.   A. Description of LED Callouts   1. IGNITION   Note: the overcrank, oil pressure, engine temperature   and spare circuits are locked out for 30 seconds during   The ignition LED will come on when the system receives start up. They require normally open sensors (close to   a signal to start. If the alarm before start is used, this operate). A summary output is available (Terminal 20 on   ignition LED will NOT come on until the 5 second alarm the A88-F and the brown wire of the A88.) for remote   goes off.   indication when a shutdown occurs.   2. PICKUP PRESENT   When the engine is cranking or running and the pickup is   B. Description of AOT Switch, Crank Disconnect   Control & Rest/Crank Time Control   connected properly with sufficient output voltage (2 volt 1. AUTO-OFF-TEST   rms) this LED will come on. IMPORTANT - This LED   must come on or the unit will not operate properly.   a. OFF   When a shutdown occurs, this unit must be removed   from power to reset. The Auto-Off-Test switch removes   power when placed in the off position. The green LED   will go off. The unit should be left off 8-10 seconds   to allow the circuitry to discharge and stabilize.   b. TEST   This position is used after all connections have been   made or for periodic checks that should be a part of a   preventive maintenance program. The start and stop   inputs are by-passed when this switch is placed in the   test position. The unit will automatically initiate the   crank cycle.   Note: this LED will NOT be on if a mechanical switch is   used as a crank disconnect sensor.   3. CRANK   The crank LED is on when the engine is cranking and is   used to show that the crank circuitry is functioning   properly.   The crank solenoid will be connected to terminal 1 of the   A88-F or the white/brown wire of the A88, if the solenoid   is connected to positive to operate.   If the crank solenoid is grounded to operate, connect it to   terminal 2 of the A88-F or connect it to the white/red wire of   the A88.   c. AUTO   For normal operation and after the system has been   tested, Place the switch in this position. It indicates   the controller will take over starting and stopping the   engine.   4. CRANK DISCONNECT   This LED comes on when the crank disconnect   adjustment is adjusted to disengage the starter. When   this LED comes on, the crank LED goes out. (See item B-   2 for control setting adjustments)   Note: these units may have a 4-5 second alarm before start.   The A88-F comes with the alarm hooked up by connection   of terminals 16 and 17. The A88 comes without the alarm   hooked up; if alarm is needed, ground the red/white wire.   Although it is an optional hook up, it is recommended that   this alarm be used to alert personnel of a start.   5. CHOKE   This LED will come on for approximately 3-4 seconds at   the beginning of each crank cycle and then go out. If a   choke or compression release solenoid is connected from   battery positive to Terminal 3 (A88-F)or the violet wire   (A88) it will be energized when the LED comes on.   2. CRANK DISCONNECT CONTROL   Adjust this control to make the crank circuit disengage the   starter when the engine starts. Rotating it counter-   clockwise makes the starter drop out at lower RPM.   6. OVERCRANK   If the engine is called on to start and fails after 5 tries, this   LED will come on and stay on to indicate cause of   shutdown.   3. REST AND CRANK TIME   By placing this switch in one of the 4 positions, the rest   and crank time is selected. If the switch is placed in the   10 seconds position, the system will crank the engine for   10 seconds, then rest for 10 seconds.   7. OIL PRESSURE   The oil pressure LED will come on if oil pressure is lost   during operation and remain on to indicate cause of   shutdown. Terminal 11 of the A88-F or the black/white   wire of the A88 are connected to the oil pressure switch.   Note: if the engine starts momentarily, then dies, it will go   into a 25-30 second rest period before it attempts another   crank. This is regardless of what position the crank and   8. ENGINE TEMPERATURE   If the unit is shutdown because of high engine temperature, rest switch is in.   this LED will be on. The temperature sensor is connected to   Terminal 12 of the A88-F or the blue/white wire of the A88.   When the system is called on to crank the first crank cycle   will be typically 50% longer than the remaining four tries.   This feature will aid in starting a cold engine.   3 Download from Www.Somanuals.com. All Manuals Search And Download.   SECTION IV: OPTIONAL HOOKUPS   In this section the terms Sink and Source are used.   3. CRANK CONNECTIONS   Sink: This terms refers to an output that switches to   A88-F   Terminal   Output   Operation Current   Max.   A88 wire color Connected   ground to do work.   Lamp   Solenoid   A Crank   No. 1   White/Brown   White/Red   Source   1 A   Switch   to Ground   Solen. to   batt. pos.   Sink   B Crank   No. 2   Terminal   If the crank solenoid is already connected to ground,   connect to the unit as indicated in "A" above.   If the crank solenoid is already connected to the battery   positive, connect it as in "B" above.   Source: This term will be used to refer to an output that is   switched to positive to do work.   Lamp   4. ENGINE RUNNING   Switch   If it is desirable to know or indicate when the engine is   actually running, connect the indicator to the battery   positive and then as below:   Terminal   A88-F   Output   Operation Current   Max.   Output   A88 Wire color   1. CHOKE   Terminal   To use this feature, connect the choke or compression   release solenoid to the battery positive and then to the   terminal or wire shown:   After 30   sec. delay   Sink   Engine   Running   No. 18   Yellow   1 A   After the engine has been running for approximately 30   seconds, the indicator will be energized.   A88-F   Terminal   Output   Operation Current   Max.   Output   A88 Wire color   Choke   No. 3   Violet   Sink 1 A   5. WARM UP   If it is desirable to have a warm up period or a 90 second   delay after the engine has started, connect the engine   running output to the time delay input and then connect   the time delay to the gas feed or clutch mechanism.   Terminal 18 to terminal 9 on the A88-F, the yellow wire to   the violet/white wire on the A88 unit.   At the beginning of each crank cycle, the choke or   compression release solenoid will pull in, remain in for 3   or 4 seconds. The maximum current this circuit can carry   is 1 amp.   2. SUMMARY   Connect the clutch or gas feed solenoid to battery positive   For a remote shutdown or alarm feature after a shutdown then to the time delay output terminal 19 on the A88-F;   occurs, connect the alarm or lamp to the battery positive the orange wire on the A88.   then to the terminal or wires shown:   After the engine starts and has been running for approx-   imately 90 seconds, the clutch or gas feed will be energized.   A88-F   A88   Output   Operation Current   Max.   Output   Terminal Wire color   1/2 A   Sink   Summary   No. 20 Brown   4 Download from Www.Somanuals.com. All Manuals Search And Download.   SECTION V: OPERATION   Refer to Diagrams 1 and 3: Basic Wiring Hookup for Step No. 8, Clutch or Warmup Operation:   correct connections to your engine.   If a warm up feature is desired see Section IV:   Optional Hookups paragraph 5 WARM UP.   Diagram 2 shows wire colors that correspond to the A88   plug and hookup wire, in the event of two colors the first   color is the primary color and the other is a tracer color.   Diagram 4 identifies the A88-F wiring terminals.   A88   To   Clutch   Control   Batt.+   Yellow   Step No. 1, Pickup:   Determine the type of pickup to be used and connect   it to the controller as illustrated in the basic wiring   hookup.   Slave   Relay   Diode   Orange   Violet/White   Clutch activates approximately 90 seconds after   engine has started—pulls in after engine stops.   Step No. 2, Starter Solenoid:   Determine the type of starter solenoid used on your   engine. In most cases it will be of the source type, that   is, one side of the pull in coil is connected to ground and   and the other has to be connected through the ignition   to positive. Do not connect the controller output directly   to the starter, always use a starter slave solenoid.   A88-F   To   Clutch   Control   Batt.+   18   Slave   Relay   Diode   Step No. 3, Ignition:   9 19   The type of ignition must be determined and wired   accordingly. Most later models will be of the CDI type.   Clutch activates approximately 90 seconds after   engine has started—pulls in after engine stops.   Step No. 4, Start/Stop   Select the type of Start/Stop control needed and wire   accordingly. If a close to run and open to stop is used   be sure and connect the brown/white and the   grey/white together. On the A-88-F connect terminals   16 and 17. It is recommended that the alarm before   start be used for safety.   Step No. 9, Crank disconnect adjustment:   To adjust the crank disconnect, disconnect the ignition   wire or leave the fuel cut off. That will let the engine   crank but not start.   Turn the crank disconnect control fully clockwise (15   turns). This control does not have a stop and it does   not hurt it to turn it more than 15 turns.   Step No. 5, Choke:   If a choke or pressure release feature is needed con-   nect the choke solenoid to battery positive then to   terminal 3 of the A-88-F or to the violet wire of the A-88.   Place the the crank and rest time switch in the 10 or   15 second position. Switch the controller in the test   position. With the engine cranking, rotate the control   counter-clockwise until the starter drops out. Notice   that the engine will crank longer the first time.   Step No. 6, Shutdown:   Connect the shutdown circuits. The spare should be   marked or labeled on the blank space.   When the starter kicks out, rotate the control clock-   wise for approximately 1(one) turn. The crank   disconnect is now set.   Step No. 7, Time Delay:   This system has a 60 second built-in time delay for   customer use. If the appropriate inputs are grounded, it   times out after the crank disconnect light comes on.   NOTE: When installing relays or solenoids that are   controlled by this controller always install a diode directly   across the coil windings to help eliminate the back EMF.   Input   Delay   Output   + A88 ground   60   Orange wire   violet/white wire   seconds   Sinks to ground   Solenoid   Diode   or   A88-F ground   Terminal 9   60   seconds   Terminal 19   Sinks to ground   Coil   5 Download from Www.Somanuals.com. All Manuals Search And Download.   Remote Annunciator Connection   1 amp max   Pickup Signal Source Connection   Use Only One   Starter Solenoid Connection   Use Only One, 1 amp max   To Batt. +   To Batt. +   To Batt. +   To Batt. +   A88   Mini Auto   Starter   1 2 3   To Starter   To Starter   Electronic or   Breaker Type   Ignition   Solenoid   Solenoid   Switched to   Positive(source)   Magnetic   Pickup   Vacuum   Switch   Fly Wheel   ALT.   Tach O/P   ALT   Engine   Running   Shutdown   Summary   Switched to   A88 cable   Blk 18 GA   Red 18 GA   Ground(sink)   Grey   Blue   Battery   White/Black   Green   SWICHGAGE® Inputs   Oil   White/Red   White/Brown   Yellow   Brown   Black/White   Temperature   Green/White   Brown/White   Grey/White   Red/White   White   Blue/White   Spare   For Momentary   For Momentary   Type Operation   SPDT   Type Operation   Close to Run   Open to Stop   N.O.   To Batt. +   Wht/Yel   White/Orange   White/Yellow   Violet/White   C Wht/Ong   White   SPST   N.C.   Grn/Wht   Yellow/White   Violet   To Batt. +   Brn/Wht   Stop   Grn/Wht   Start   Orange   Brown/White   Grey/White   Ignition Connection   CDI Type 6 amp max   Ground to Kill   Load   1/2 A   Grey/White No Connection   Connect   Ignition Connection   Breaker Type, 6 amp max   Red/White ground for   5 seconds Alarm On Start   Grounding   Violet/White   will cause Orange   to Grnd 60 sec Later   Red/White ground for   5 seconds Alarm On Start   Ignition Connection   (Use only one)   Choke Connection   Pulls in for 3-4 sec.   Start/Stop Control Connection   (Use only one)   NOTE: First is color of wire, second color is tracer.   EXAMPLE: (White/Red)   White is color, Red is trace color   Diagram 1: A88 Basic Wiring Hookup   Download from Www.Somanuals.com. All Manuals Search And Download.   Pin 1-wire-Wht/Blk: Breaker ignition I/P   Pin 2-wire-Green: Vacuum switch I/P   Pin 3-wire-Viol/Wht: Grnd for time delay I/P   Pin 4-wire-Grey: Magnetic pickup I/P   Pin 5-wire-Blue: Tach alternator I/P   Pin 6-wire-Violet: Choke (sink) O/P   Pin 7-wire-Wht/Red: Crank (sink) O/P   Pin 8-wire-Yellow: Engine running (sink) O/P   Pin 9-wire-Grn/Wht: Start I/P   Pin 10-wire-Red/Wht: Connect #11 for alarm   Pin 11-wire-Ong/Wht: Connect #10 for alarm   Pin 12-wire-Black: Battery negative (–)   Pin 13-wire-Red: Battery positive (+)   Pin 14-wire-Brn/Wht: Stop I/P   Pin 15-wire-Grey/Wht: Connect to #14 for close to   run-open to stop operation   Pin 16-wire-Wht/Brn: Crank (source) O/P   Pin 17-wire-Yel/Wht: Spare I/P   Pin 18-wire-Blue/Wht: Water temp. I/P   Pin 19-wire-Blk/Wht: Oil pressure I/P   Pin 20-wire-Brown: Shutdown summary (sink) O/P   Pin 21-wire-Wht/Ong: Ignition relay Common   Pin 22-wire-White: Ignition relay N.O.   Pin 23-wire-Wht/Yel: Ignition relay N.C.   Pin 24-wire-Orange: Time delay (sink) O/P   Diagram 2: A88 Wiring Harness   Download from Www.Somanuals.com. All Manuals Search And Download.   Starter Solenoid Connection   Use Only One, 1 amp max   Use Continuous Duty Solenoid   Remote Annunciator Connection   1 amp max   Pickup Signal Source Connection   Use Only One   To Batt. +   To Batt. +   To Batt. +   To Batt. +   A88-F   Mini Auto   Starter   1 2 3   To Starter   To Starter   Electronic or   Breaker Type   Ignition   Solenoid   Solenoid   Switched to   Positive(source)   Magnetic   Pickup   Vacuum   Switch   Fly Wheel   ALT.   Tach O/P   ALT   Engine   Running   Shutdown   Summary   Switched to   Ground(sink)   25   26   6 7 Battery   5 8 SWICHGAGE® Inputs   Oil   2 1 18   20   4 11   Temperature   17   16   15   23   21   22   12   For Momentary   For Momentary   Type Operation   SPDT   NO   C Type Operation   Close to Run   Open to Stop   To Batt. +   Spare   SPST   NC   9 13   3 To Batt. +   19   Time Delay   Output   Stop   Start   Ignition Connection   CDI Type 6 amp max   Ground to Kill   16 No Connection   Connect   Ignition Connection   Load   1/2 A   Breaker Type, 6 amp max   Ground for 5 seconds   Alarm On Start   Ground for 5 seconds   Alarm On Start   Grounding 9   will cause 19 to ground   60 seconds Later   Ignition Connection   (Use only one)   Choke Connection   Pulls in for 3-4 sec.   Start/Stop Control Connection   (Use only one)   Diagram 3: A88-F Basic Wiring Hookup   Download from Www.Somanuals.com. All Manuals Search And Download.   Terminal 21: Common   Terminal 22: Normally Closed (N.C.)   Terminal 23: Normally Open (N.O.)   Terminal 24: No Connection   Terminal 25: Negative (–)   Terminal 26: Positive (+)   Ignition Relay   Terminal 11: Oil pressure I/P   Terminal 12: Water temperature I/P   Terminal 13: Spare I/P   Terminal 1: Crank (source)   Terminal 2: Crank (sink)   11   12   13   14   15   16   17   18   19   1 2 3 4 5 6 7 8 9 26 25 24 23 22 21   Terminal 3: Choke (sink)   Terminal 14:   before start   Terminal 15:   Terminal 4: Start I/P   Jumper for alarm   Terminal 5: Breaker ignition I/P   Terminal 6: Magnetic pickup I/P   Terminal 7: Alternator I/P   Terminal 16: Connect to #17 for   momentary operation   Terminal 17: Stop I/P   Terminal 8: Vacuum switch I/P   Terminal 9: Ground for time delay I/P   Terminal 10: No connection   Terminal 18: Engine running (sink)   Terminal 19: Time delay (sink)   Terminal 20: Alarm summary (sink)   20   10   Diagram 4: A88-F Wiring Terminals   Download from Www.Somanuals.com. All Manuals Search And Download.   Customer Hookup for Honda Generator   Model EM3500SX/EM5000SX   Starter   * Slave Relay   1 Amp Max   Blue   Grey   Close To Run   Open To Stop   Charging   Coil   Float Switch   * Fuel   Valve   100 1/2 W   D1   * Green   Yellow   * R1   * K1   IN4005   Oil Press. Shutdown   Oil   Level   Switch   Ground for Alarm   Before Start   As shown, when float   closes the 4-5 seconds   alarm will then start.   A88   or   A88-F   * Customer supplied.   Diagram 5: A88/A88-F Wiring for Honda Generator   10   Download from Www.Somanuals.com. All Manuals Search And Download.   Customer Hookup for Honda Generator   Model CSX360   * Customer supplied.   ** Starter solenoid or 10A 12V relay.   E Black   * Charge   Coil   E ST   Black/White   Black/Yellow   Combination   Switch   LO   IG   BAT   Black/Red   White/Black   **   * Closed to   Start   Open to   Stop   Connect   A88   or   A88-F   Diagram 6: A88/A88-F Wiring for Honda Generator   019699   11   Download from Www.Somanuals.com. All Manuals Search And Download.   |