Chapter 1 – Description and Specifications ..............................................................................................................5  
Introduction.................................................................................................................................................................5  
Safety Warnings .........................................................................................................................................................5  
MultiModem Package Contents..................................................................................................................................5  
AT Commands............................................................................................................................................................5  
Features and Technical Specifications.......................................................................................................................6  
Electrical Specifications..............................................................................................................................................7  
LED Indicators............................................................................................................................................................7  
RS-232 9-Pin Connector ............................................................................................................................................7  
About the Leased-Line Operation Feature .................................................................................................................8  
Setup.....................................................................................................................................................................8  
Chapter 2 – Installation................................................................................................................................................9  
Step 1 – Desktop Placement or Panel-Mounting........................................................................................................9  
Step 2 – Connect the Modem to Your System..........................................................................................................10  
For AC Power......................................................................................................................................................10  
For DC Power......................................................................................................................................................10  
Step 3 – Install the Modem Driver ............................................................................................................................11  
Step 4 – Configure the Modem for Your Country or Region.....................................................................................11  
Using the Global Wizard......................................................................................................................................11  
Using AT Commands ..........................................................................................................................................11  
Step 5 – Install Data Communications Software.......................................................................................................12  
PhoneTools .........................................................................................................................................................12  
Chapter 3 – AT Commands, S-Registers and Result Codes ..................................................................................13  
Chapter 4 – Remote Configuration...........................................................................................................................14  
Basic Procedure .......................................................................................................................................................14  
Setup........................................................................................................................................................................14  
Changing the Setup Password ............................................................................................................................14  
Changing the Remote Escape Character............................................................................................................14  
Chapter 5 – Callback Security...................................................................................................................................15  
Changing the Setup Password .................................................................................................................................15  
Turning Callback Security On and Off ......................................................................................................................15  
Setting Callback Security Message Parity................................................................................................................16  
Assigning Callback Passwords and Phone Numbers...............................................................................................16  
Calling Procedures ...................................................................................................................................................16  
Password-Only Callback .....................................................................................................................................16  
Number-Entry Callback .......................................................................................................................................17  
Extension-Entry Callback ....................................................................................................................................17  
Direct Connection................................................................................................................................................18  
Callback Security Commands..............................................................................................................................18  
Chapter 6 – Troubleshooting ....................................................................................................................................19  
None of the Indicators Light......................................................................................................................................19  
The Modem Does Not Respond to Commands........................................................................................................19  
The Modem Cannot Connect When Dialing .............................................................................................................20  
The Modem Disconnects While Online.....................................................................................................................21  
Modem Cannot Connect When Answering...............................................................................................................21  
File Transfer Is Slower Than It Should Be................................................................................................................21  
Data Is Being Lost ....................................................................................................................................................22  
There Are Garbage Characters on the Monitor ........................................................................................................22  
The Modem Doesn’t Work with Caller ID..................................................................................................................22  
Fax and Data Software Can’t Run at the Same Time...............................................................................................22  
Appendix A – Flash Upgrade ....................................................................................................................................23  
Appendix B – Regulatory Compliance .....................................................................................................................24  
Regulatory Compliance Statements .........................................................................................................................24  
EMC, Safety, and R&TTE Directive Compliance.................................................................................................24  
International Modem Restrictions ........................................................................................................................24  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Telecom Requirements for the United States......................................................................................................24  
Industry Canada ..................................................................................................................................................24  
New Zealand Telecom Warning Notice ...............................................................................................................25  
South African Statement......................................................................................................................................25  
Other ...................................................................................................................................................................25  
Appendix C – Multi-Tech Warranty Statement and Product Repair.......................................................................26  
Warranty...................................................................................................................................................................26  
Product Repair..........................................................................................................................................................26  
Repair Procedures for U.S. and Canadian Customers........................................................................................26  
Repair Procedures for International Customers (Outside U.S.A. and Canada) ...................................................27  
Repair Procedures for International Distributors..................................................................................................27  
Replacement Parts..............................................................................................................................................27  
Index............................................................................................................................................................................28  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 – Installation  
Chapter 1 – Description and  
Specifications  
Introduction  
This guide highlights the features and specifications of the MT5634IND modem and shows you how to set up and  
operate your Multi-Tech MultiModemIND.  
Safety Warnings  
Use this product only with UL- and CUL-listed computers (US).  
Never install phone wiring during a lightning storm.  
Never install a phone jack in a wet location unless the jack is specifically designed for wet locations.  
Never touch uninsulated phone wires or terminals unless the phone line has been disconnected at the  
network interface.  
Use caution when installing or modifying phone lines.  
Avoid using a phone during an electrical storm; there is a risk of electrical shock from lightning.  
Do not use a phone in the vicinity of a gas leak.  
To reduce the risk of fire, use only 26 AWG or larger telephone line cord.  
MultiModem Package Contents  
AC-Powered Version  
One MT5634IND industrial data/fax modem  
Two mounting brackets  
RS-232 serial cable  
One RJ-11 phone cable  
One universal power supply with power cord  
One printed Quick Start Guide  
One MT5634IND product CD containing the modem drivers, User Guide, Quick Start Guide, AT  
Commands Reference Guide, Fax Commands Reference Guides, Global Wizard software, PhoneTools  
(a data communications program), and Acrobat Reader  
DC-Powered Version  
One MT5634IND industrial data/fax modem  
Two mounting brackets  
RS-232 serial cable  
One RJ-11 phone cable  
One fused power cable  
One printed Quick Start Guide  
One MT5634IND product CD containing the modem drivers, User Guide, Quick Start Guide, Global  
Wizard software, PhoneTools (a data communications program), and Acrobat Reader  
AT Commands  
AT commands and Fax commands for the MT5634IND modem are published in separate Reference Guides included  
on the MultiModemIND CD and posted on the Multi-Tech Web site.  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 – Installation  
Features and Technical Specifications  
Data Interface  
Data Rates  
Serial, Binary, Asynchronous  
Serial interface supports speeds up to56K  
Server-to-Client Data  
Rates  
56K speeds when accessing a server (actual speed depends on server capabilities  
and line conditions)  
Client-to-Server Data  
Rates  
Up to 48Kbps when accessing a V.92 server (actual speed depends on server  
capabilities and line conditions); otherwise, the same rates as client-to-client data  
rates apply (see Client-to-Client Data Rates).  
33600, 31200, 28800, 26400, 24000, 21600, 19200, 16800, 14400, 12000, 9600,  
7200, 4800, 2400, 1200, 0-300 bps  
Client-to-Client Data  
Rates  
Fax Rates  
33600, 31200, 28800, 26400, 24000, 21600, 19200, 16800, 14400, 12000, 9600,  
7200, 4800, 2400, 300 bps  
Modem Compatibility  
Fax Compatibility  
V.92, V.90, V.34, V.32bis, V.32, V.22bis, V.22, Bell 212A and 103/113, V.21, V.23,  
V.42bis, V.44  
ITU-T “Super” Group 3; Class 1.0, 2.0, 2.1; T.4; T.30; V.21; V.27ter; V.29; V.34; V.17;  
and TIA/EIA Class 1, 2; TR29.2  
Error Correction  
Data Compression  
Flow Control  
V.42  
V.44, V.42bis  
XON/XOFF; hardware (RTS/CTS)  
Transmit Level  
Environmental  
-13 dBm  
Temperature range -40°C to +85°C  
Mechanical Dimensions 4.3" w x 2.4" h x 0.94" d; 4.2 oz.  
& Weight  
(11 cm x 6.1 cm x 2.4 cm; 120 g)  
Command Buffer  
Other Features  
60 characters  
Global approvals in many countries for worldwide use  
Desktop or panel mounting  
Industrial chassis (a rugged, water-resistant, industrial chassis made of aluminum)  
Automatic fallback to slower speeds in noisy line conditions and fall-forward to faster  
speeds as conditions improve  
Fully AT command compatible  
2-wire leased-line support  
Flash memory for easy updates  
Callback security; Remote configuration  
Caller ID (in U. S.)  
Autodial, redial, repeat dial, dial pauses; Pulse or tone dial and touch-tone dial  
Dial tone and busy signal detection for reliable call progress reporting  
Nonvolatile memory for storage of custom settings and two telephone numbers  
Call status display  
Auto parity and data rate selections  
On-screen displays for modem option parameters  
Manufacturing  
Information  
Trade Name:  
Model Number:  
Registration Number:  
MultiModem  
MT5634IND  
The embedded SocketModem MT5634SMI is the registered  
part of this product: AU7USA-25814-M5-E  
0.3B  
Ringer Equivalence:  
Modular Jack (USOC): RJ11  
Certification  
EMC Safety Approvals:  
FCC Part 15 Class B – Emissions for U.S.A. and Canada  
EN55022 Class B – Emissions for EU countries. Needed for CE marking  
EN55024 – Immunity for EU countries. Needed for CE marking  
EN61000-6-2 – Immunity for industrial environments  
Safety Certifications:  
UL60950-1 – U.S.A. and Canada Safety  
EN60950-1 – Safety for EU countries. Needed for CE marking  
GR1089 – Clause 4 NEBS Tested  
Reliability:  
Temperature Range: -40°C to +85°C  
EN60068-2-6 – Vibration 10 to 500 Hz sine vibration 5g  
EN60068-2-30 – Temp/Humidity Damp Heat cycling  
EN60068-2-1 – Cold (-40°C)  
EN60068-2-2 – Dry Heat (+85°C)  
EN60068-2-14 – Change of Temperature (-40°C to +85°C)  
IEC 68-2-27 – Shock – 3 shocks/3mS duration 50g  
5 years  
Warranty  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 – Installation  
Electrical Specifications  
Power Consumption  
Typical: 155 mA (.945 W @ 9V DC) 180 mA maximum  
155 mA @ 6V DC  
96 mA @ 10V DC  
68 mA @ 15V DC  
54 mA @ 20V DC  
38 mA @ 30V DC  
30 mA @ 40V DC  
26 mA @ 48V DC  
Power Requirements  
6V DC +/- 5% to 48V DC +/- 10%  
LED Indicators  
LED  
TD  
Description  
Transmit Data. This LED is lit when modem is transmitting data to another modem.  
RD  
Receive Data. This LED is lit when the modem receiving data from another modem.  
CD  
Carrier Detect. This LED is lit when the modem detects a valid carrier signal from another modem. It is  
on when the modem is communicating with the other modem and off when the link is broken.  
TR  
Terminal Ready. (Also called Data Terminal Ready.) This LED indicates the PC is turned on and ready  
to communicate. This LED is lit when a data communications program initializes the modem. It goes  
off when the communications program disconnects the COM port. When is goes off, a connected  
modem will disconnect.  
PWR  
Power. This LED Indicates the presence of DC power when lit.  
RS-232 9-Pin Connector  
Pin  
1
Description  
DCD  
2
3
4
RX Data  
TX Data  
DTR  
5
6
Ground  
DSR  
7
RTS  
8
CTS  
9
RI  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 – Installation  
About the Leased-Line Operation Feature  
The MultiModemIND can be used on a two-wire leased line.  
A leased line is a private, permanent telephone connection between two points. Unlike normal dialup connections, a  
leased line is always active. The modems automatically connect when they are attached to the line and are turned  
on. Because a leased line is always active, one of the two modems on the line must be configured as the originate  
modem and the other as the answer modem; however, it does not matter which is which.  
In the event of an interruption, leased-line modems automatically reconnect when the data line or power is restored.  
Setup  
1. Connect a modular telephone cable to the LINE jack. Connect the other end of the cable to a two-wire  
lease-line jack or terminals supplied by the telephone company.  
2. Turn on the modem.  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 – Installation  
Chapter 2 – Installation  
Step 1 – Desktop Placement or Panel-  
Mounting  
The MT5634IND is design to be used on the desktop or to be panel-mounted. For panel-mounting, follow these  
directions for attaching the mounting brackets:  
1. Typically, the modem is mounted against a flat surface with two mounting screws. Drill the mounting holes at  
the desired location. The mounting holes must separated by 4 -7/16 inches center-to-center.  
2. To attach the brackets to the modem, slide the mounting brackets into the corresponding slots on the back  
of the chassis.  
3. Attach the modem to the surface with two screws.  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 – Installation  
Step 2 – Connect the Modem to Your  
System  
For AC Power  
Turn off your computer. Place the modem in a convenient location, and then connect it to your computer’s serial  
port, the phone line, and AC power.  
For DC Power  
For DC power, use the fused cable in place of the Universal Power Supply and the AC Power Cord.  
Fused  
Cable  
Fused Cable  
Connection  
Steps for connecting Your Modem to Your System  
RS-232 Connection  
Plug one end of the serial cable into the RS-232 connector on the modem, and plug the other end into a  
serial port connector on your computer, such as COM1 or COM2.  
Phone Line Connection  
Plug one end of the phone cable into the MT5634IND LINE jack and the other end into a phone line wall  
jack.  
Power Connection  
For AC  
Plug the power supply cable with attached transformer block into the power connector on the  
MultiModem. Then plug the AC cord receptacle into the transformer block, and plug the other end of the  
of the AC cord into a power outlet or power strip.  
Note: Use only the power supply supplied with the MT5634IND. Use of any other power supply will void  
the warranty and could damage the modem.  
For DC  
Plug the fused cable into the power connector on the MultiModem. Then attach the two wires at the  
other end of the fused cable to a DC power source.  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 – Installation  
Step 3 – Install the Modem Driver  
If you use Windows 98+, you must install the modem driver, which is installed using the Windows Plug and Play  
feature. Follow the four-step procedure below. If you use another operating system, see your operating system  
manual.  
1. Make sure your modem is connected properly, and then turn on your computer. Windows should detect your  
new modem and open the Install New Modem wizard.  
2. Insert the MT5634IND product CD, and then click OK.  
3. Windows installs and configures the modem.  
4. Click Finish to exit.  
Windows NT – The Install New Modem wizard presents one additional prompt before Step 2. At this prompt,  
select: Don’t detect my modem; I will select it from a list, and then click Next.  
A dialog box with a list of manufacturers and a list of modem models appears. Select the Multi-Tech Systems  
MT5634IND (the driver is named Multi-Tech MT5634SMI-V92-IND).  
Note: If Windows cannot identify your modem (for instance, if it identifies your modem as a “Standard Modem”),  
click Change. Return to the MT5634IND CD and open the drivers section. Select the Multi-Tech MT5634SMI-  
V92-IND driver.  
Step 4 – Configure the Modem for Your  
Country or Region  
Different countries have different requirements for how modems must function. Therefore, before you use your  
modem, you must configure it to match the defaults of the country/region in which you are using it. You must also do  
this if you move the modem to another country/region after it has been configured for the first country/region. You can  
use one of two country/region configuration methods:  
The Global Wizard  
AT Commands  
Using the Global Wizard  
The Global Wizard configuration utility isrecommended for computers running Windows 95 or newer.  
1. Insert the MultiModemIND product CD into the CD-ROM drive. The Autorun menu should appear.  
2. Click Initial Setup and Country/Region Selection.  
3. Choose either:  
Run Global Wizard from CD. This will not load the wizard onto your hard drive, or  
Install Global Wizard on the HD. This will install the wizard onto your PC for future use.  
4. The Global Wizard dialog box appeared. Click Next.  
5. The Global Wizard searches for your modem and identifies it. Click Next.  
6. Select the country/region in which the modem will be used. Click Next.  
7. Review your country/region choice. If it is correct, click Next to configure the modem.  
8. When Global Wizard announces that the parameters have been set, click Finish to exit.  
Using AT Commands  
Non-Windows users can configure the modem using AT commands. You must enter these commands in your  
communication program’s terminal window. To configure the country/region code, the initialization string must  
contain the AT command for your specific country or region.  
1. Run a communications program, such as PhoneTools (included on the MT5634IND CD) or  
HyperTerminal.  
2. Type AT%T19,0,nn, where nn is the country/region code in hexadecimal notation.  
Click Enter. The message OK displays.  
3. To verify that the correct country/region has been configured, type:  
ATI9 and click Enter.  
4. The country/region code displays:  
Example:  
Country/Region  
AT Command (hexadecimal)  
Result code (decimal)  
Euro/NAM  
AT%T19,0,34 (default)  
52  
A list of country/region codes can be found on the Multi-Tech Web site at  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 – Installation  
Step 5 – Install Data Communications  
Software  
Data communications software is designed to send and receive messages. Multi-Tech includes PhoneTools, a  
communications software program with your modem. However, the modem will work with other data communications  
software, such as HyperTerminal.  
To install PhoneTools, insert the CD into the CD-ROM drive; click the PhoneTools icon. You will be asked to choose  
your language. The software automatically loads onto your PC.  
PhoneTools  
PhoneTools is a data communications program included as part of your MultiModemIND purchase. With this  
software you can:  
Upload and download data files.  
Send faxes at preset times.  
Store incoming voice messages and faxes.  
Retrieve stored messages, faxes, and telephone numbers (telephone number retrieval requires Caller ID  
service from your telephone company).  
Print a received fax.  
For detailed information about operating your modem under PhoneTools, please refer to the PhoneTools user  
documentation included with the PhoneTools software.  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3 – AT Commands, S-Registers, and Result Codes  
Chapter 3 – AT Commands, S-Registers  
and Result Codes  
AT commands and Fax commands for the MT5634IND are published in a separate Reference Guide included on the  
MT5634IND CD and posted on the Multi-Tech Web site.  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4 – Remote Configuration  
Chapter 4 – Remote Configuration  
Remote configuration is a network management tool that allows you to configure MT5634IND modems anywhere in your  
network from one location. With password-protected remote configuration, you can issue AT commands to a remote  
modem for maintenance or troubleshooting as if you were on site.  
Basic Procedure  
The following steps can be used when the connection is established by the local or the remote modem.  
Note: The remote computer must be running and a communication program must be ready for a data connection, which  
will be indicated by a lighted TR indicator on the front of the modem.  
1. Establish a data connection with a remote MT5634IND modem.  
2. Send three remote configuration escape characters followed by AT and the setup password, and press Enter.  
Example: %%%ATMTSMODEM.  
You have four tries to enter the correct password before being disconnected. If the password is correct, the  
remote modem responds with OK.  
3. You can now send AT commands to configure the remote modem.  
4. When you have finished configuring the remote modem, save the new configuration by typing AT&W0 and  
pressing Enter.  
5. Type ATO and press Enter to exit remote configuration. You can now break the connection in the normal way.  
Setup  
Multi-Tech modems are shipped with a default setup password (MTSMODEM). Because anyone who has the User  
Guide knows the default setup password, you should change the password.  
Changing the Setup Password  
1. Open a data communications program such as HyperTerminal or PhoneTools.  
2. In the terminal window, type AT#SMTSMODEM (or AT#Sxxxxxxxx if you have replaced the  
MTSMODEM password with xxxxxxxx) and press ENTER. The modem responds with OK if the setup  
password is correct, and ERROR if it is wrong.  
3. To change the password, type AT#S=xxxxxxxx, where xxxxxxxx stands for the password, and then  
press ENTER. The password can include any keyboard character, and can be up to eight characters long.  
The modem responds with OK.  
CAUTION: Passwords are case-sensitive. The next time you enter the password, it must be in the same  
case as you set it up.  
4. The new password is saved automatically. You can now either enter more AT commands or exit the data  
communications program. The next time you wish to set up the modem, you must use the new password.  
Changing the Remote Escape Character  
To further improve security, you can change a remote modem’s remote configuration escape character either  
locally or remotely. The remote configuration escape character is stored in register S9. The factory default is 37,  
which is the ASCII code for the percent character (%). Setting S9 to 0 (zero) disables remote configuration  
entirely. CAUTION: If you do this remotely, you won’t be able to change it back remotely.  
1. Establish a remote configuration link with the remote modem as described in Basic Procedure.  
2. Type ATS9=n, where n is the ASCII code for the new remote configuration escape character, and then  
press Enter.  
3. Save the new value by typing AT&W and pressing Enter.  
4. Type ATO and press Enter to exit remote configuration.  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 5 – Callback Security  
Chapter 5 – Callback Security  
This chapter describes how to use callback security with your modem. Callback security protects your network from  
unauthorized access and helps control long-distance costs. When callback security is enabled, all callers are  
requested to enter a password. If a valid password is received, the modem hangs up and returns the call by dialing a  
phone number that is stored with the password. The person being called back must then enter the password a  
second time to establish a connection.  
Up to 30 callback passwords and dialing strings can be stored in the modem. Each dialing string can be up to 34 or  
35 characters long and can contain commands as well as phone numbers. For mobile callers, the dialing string can  
be programmed to allow the caller to bypass the stored callback number by entering a temporary callback number, to  
enter an extension at the callback number, or to make a direct connection without callback.  
For local security, the passwords and dialing strings that are stored in the modem are protected from tampering by a  
setup password, which you should change when you set up the modem. You can further protect the modem against  
tampering by disabling its ability to respond to most AT commands. To check for attempted break-ins, you can  
request the modem to display the number of failed password attempts.  
Your modem was shipped with a default setup password (MTSMODEM). The same password is used for both  
callback security and remote configuration. Because anyone who has access to this guide has access to the default  
password, you should change the password during your initial setup.  
Changing the Setup Password  
1. Open a data communications program such as PhoneTools.  
2. In the terminal window, type AT#SMTSMODEM (or AT#Sxxxxxxxx if you have replaced the MTSMODEM  
password with xxxxxxxx). Press ENTER. The modem responds with OK if the setup password is correct and  
ERROR if it is wrong.  
3. To change the password, type AT#S=xxxxxxxx, where xxxxxxxx stands for the password, and then press  
Enter. The password can include any keyboard character, and can be up to eight characters long. The  
modem responds with OK.  
4. The new password is saved automatically. You can now either enter more AT commands or exit the data  
communications program. The next time you wish to set up the modem, you must use the new password.  
CAUTION: Passwords are case-sensitive. The next time you enter the password, it must be in the same  
case as you set it up.  
Turning Callback Security On and Off  
Callback security must be turned on to enter many callback security commands.  
1. Open a data communications program such as PhoneTools.  
2. In the terminal window, type AT#Sxxxxxxxx, where xxxxxxxx is your password. Press Enter. The modem  
responds with OK if the setup password is correct and ERROR if it is wrong.  
3. Type one of the following commands:  
To turn off callback security: Type AT#CBS0 and press Enter. Callers no longer need a password to  
connect to the modem, the modem is unable to call them back, and the stored dialing command  
locations 0–3 become available.  
To turn on both local and remote callback security: Type AT#CBS1. Press Enter. With local  
security turned on, you must enter the setup password before you can enter any AT command except  
the AT, ATIn, and AT#Sxxxxxxxx commands.  
To turn on remote callback security only: Type AT#CBS2 and press Enter. With remote callback  
security turned on, each caller is asked to enter a password, is called back, and then is asked to enter  
the password again before a connection can be made. Also, dialing command locations 0–3 for use with  
the DS=y dialing command are replaced by callback dialing command locations 0–29.  
To temporarily disable callback security if the modem is set to #CBS1 or #CBS2 (for instance, to  
call another modem): Type AT#CBS3 and press Enter. The modem returns to its original setting  
when you issue the hangup command (+++ATH) or the modem is reset. Note that if a remote modem  
breaks the connection, callback security remains disabled.  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 5 – Callback Security  
Setting Callback Security Message Parity  
The password prompt and messages parity must match the parity of the computer to which the modem is connected.  
1. Open a data communications program such as PhoneTools.  
2. In the terminal window, type AT#Sxxxxxxxx, where xxxxxxxx is your password. Press Enter. The modem  
responds with OK if the setup password is correct and ERROR if it is wrong.  
3. The modem’s parity default value is No parity (AT#CBP0). To change the modem’s default to use even  
parity, type AT#CBP2. Press Enter. For odd parity, type AT#CBP1. Press Enter.  
4. To store the new parity value, type AT&W. Press Enter.  
Assigning Callback Passwords and Phone  
Numbers  
1. Open a data communications program such as PhoneTools.  
2. In the terminal window, type AT#Sxxxxxxxx, where xxxxxxxx is your password. Press Enter. The modem  
responds with OK if the setup password is correct and ERROR if it is wrong.  
3. Enable callback security by typing AT#CBS1 or AT#CBS2 and pressing Enter.  
4. To store a callback password for the first callback memory location, type AT#CBN0=xxxxxxxx, where  
xxxxxxxx is the first password. Press Enter. The password must be unique, must be six to eight characters  
in length, and must not contain a + or - character.  
5. To store a callback password for the second callback memory location, type AT#CBN1=xxxxxxxx, where  
xxxxxxxx is the second password. Press Enter. Note that the memory location number in the command is  
incremented by one.  
6. Repeat as many times as necessary, up to memory location 29, until all passwords are entered.  
7. To store a callback phone number in the first memory location, type AT&Z0=[+][-]ATxxxxxxxx[,???], where  
xxxxxxxx is the dialing string. Press Enter. The phone number must be preceded by DT for tone dialing or  
DP for pulse dialing. The dialing string can also include other AT commands. Example: AT&Z0=+-  
ATM0DT5551212. Up to 35 characters can be used. The +, -, and ??? characters are optional:  
+
-
Number entry. Enables a mobile caller to enter his current phone number for callback.  
Direct connection. Enables a caller to choose direct connection without being called back.  
,??? Extension entry. Must be used with the + command. Enables a caller to enter an extension number  
for callback. The number of ? characters must equal the number of digits in the extension.  
8. To store a callback phone number in the second memory location, type AT&Z1=[+][-]ATxxxxxxxx[,???],  
where xxxxxxxx is the dialing string, and press Enter. Note that the memory location number in the  
command is incremented by one.  
9. Repeat, through memory location 29, until all dialing strings are entered.  
10. To review your entries, type AT&V and press Enter.  
Calling Procedures  
Use the following procedures to call a modem that has callback security enabled. Note that Autoanswer must be  
enabled on the calling modem (S0=1).  
Password-Only Callback  
Use this procedure when calling from a fixed location.  
1. Using a data communications program such as PhoneTools, dial the number of the callback modem.  
2. When the connection is established, the callback modem responds with the following message:  
Password>  
3. Type the password corresponding to the phone number for your modem. Press Enter. You have  
three attempts or one minute to enter a valid password.  
4. If the password is valid, the following message appears, and the modems disconnect:  
OK Disconnecting  
5. After the delay specified by the #CBDn command, the callback modem calls the number associated  
with the password. If the callback modem is unable to establish a connection, it tries again, up to the  
number of attempts specified by the #CBAn command.  
6. After the modems reconnect, the following message reappears: Password>  
7. Type the same password that you used to initiate the call. You are allowed three attempts to enter the  
password, after which you will be disconnected.  
8. If the password is valid, the following message appears and the modems establish a working  
connection: OK Connecting  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 5 – Callback Security  
Number-Entry Callback  
Mobile callers should use this procedure when calling from a phone number different from the one stored with  
the password. The password that is used must be set up for optional number-entry callback.  
1. Using a data communications program such as PhoneTools, dial the number of the callback modem.  
2. When the connection is established, the callback modem responds with the following message:  
Password>  
3. Type a number-entry password, press the plus key (+), type ATDT and the number to call back to,  
and press Enter. You have three attempts or one minute to enter a valid password.  
Note: When you type your phone number, be sure to include the long distance and area codes if they  
are needed.  
4. If the password is valid, the following message appears, and the modems disconnect:  
OK Disconnecting  
5. After the delay specified by the #CBDn command, the callback modem calls the number that you  
entered after the + character. If the callback modem is unable to establish a connection, it tries again,  
up to the number of attempts specified by the #CBAn command.  
6. After the modems reconnect, the following message reappears:  
Password>  
7. Type the same password that you used to initiate the call. You are allowed three attempts to enter the  
password, after which you will be disconnected.  
8. If the password is valid, the following message appears and the modems establish a working  
connection:  
OK Connecting  
Extension-Entry Callback  
Use this procedure when calling from an extension at the callback number. The password that you use must  
be set up for an optional extension-entry callback.  
1. Using a data communications program such as PhoneTools, dial the number of the callback modem.  
2. When the connection is established, the callback modem responds with the following message:  
Password>  
3. Type an extension-entry password, press the plus key (+), type the extension to call back to, and  
press Enter. You have three attempts or one minute to enter a valid password.  
4. If the password is valid, the following message appears, and the modems disconnect:  
OK Disconnecting  
5. After the delay specified by the #CBDn command, the callback modem calls the extension that you  
entered after the + character. If the callback modem is unable to establish a connection, it tries again,  
up to the number of attempts specified by the #CBAn command.  
6. After the modems reconnect, the following message reappears:  
Password>  
7. Type the same password you used to initiate the call. You are allowed three attempts to enter the  
password. After that, you will be disconnected.  
8. If the password is valid, the following message appears, and the modems establish a working  
connection:  
OK Connecting  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 5 – Callback Security  
Direct Connection  
Use this procedure when you want to connect without first being called back. The password that you use must  
be set up for an optional direct connection.  
1. Using a data communications program such as HyperTerminal or PhoneTools, dial the number of the  
callback modem.  
2. When the connection is established, the callback modem responds with the following message:  
Password>  
3. Type a direct connection password, press the - key, and then press ENTER. You have three attempts  
or one minute to enter a valid password.  
4. If the password is valid, the following message appears and the modems establish a working  
connection:  
OK Connecting  
Note: You can make all calls direct connect regardless of whether the password or phone number has the  
- character by using the %H1 command  
Callback Security Commands  
The AT Commands related to Callback to Security are included in the AT Commands Reference Guide included  
on MT5634IND MultiModem CD.  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 6 – Troubleshooting  
Chapter 6 – Troubleshooting  
Your modem was thoroughly tested at the factory before it was shipped. If you are unable to make a successful  
connection, or if you experience data loss or garbled characters during your connection, it is possible that the modem  
is defective. However, it is more likely that the source of your problem lies elsewhere. The following symptoms are  
typical of problems you might encounter:  
None of the LEDs light when the modem is on.  
The modem does not respond to commands.  
The modem cannot connect when dialing.  
The modem disconnects while online.  
The modem cannot connect when answering.  
File transfer is slower than it should be.  
Data is being lost.  
There are garbage characters on the monitor.  
The modem doesn’t work with Caller ID.  
Fax and data software can’t run at the same time.  
If you experience problems, please check the following possibilities before calling Technical Support.  
None of the Indicators Light  
When you turn on the modem, the LED indicators on the front panel should flash briefly as the modem runs a self-  
test. If the LEDs remain off, the modem is probably not receiving power.  
Make sure the modem’s power switch is on, especially if you normally turn the modem on by turning on a  
power strip.  
If the modem is plugged into a power strip, make sure the power strip is plugged in and its power switch is  
on.  
Make sure the power supply is firmly connected to the modem and the power supply’s power cord is firmly  
connected to both to the power supply and the wall outlet or power strip.  
If the power strip is on and the modem switch is on, try moving the power supply to another outlet on the  
power strip.  
Test that the outlet is live by plugging another device, such as a lamp, into it.  
The modem or power supply may be defective. If you have another Multi-Tech modem, try swapping  
modems. If the problem goes away, the first modem or power supply might be defective. Call Technical  
Support for assistance.  
CAUTION: Do not under any circumstances replace the power supply with one designed for another product; doing  
so can damage the modem and void your warranty.  
The Modem Does Not Respond to Commands  
Make sure the modem is plugged in and turned on. (See “None of the Indicators Light.”)  
Make sure you are issuing the modem commands from data communication software, either manually in  
terminal mode or automatically by configuring the software. (You cannot send commands to the modem  
from the DOS prompt.)  
Make sure you are in terminal mode in your data communication program, then type AT and press ENTER. If  
you get an OK response from your modem, your connections are good and the problem likely is in the  
connection setup in your communication software.  
Try resetting your modem by turning it off and on. If you are using DOS or Windows 3.1 communication  
software, make sure the initialization string includes &F as the first command, to cancel any “leftover’  
command that could affect the modem’s operation.  
If you don’t get an OK, the problem may still be in the communication software. Make sure you have done  
whatever is necessary in your software to make a port connection. Not all communication programs connect  
to the COM port automatically. Some connect when the software loads and remain connected until the  
program terminates. Others can disconnect without exiting the program. The modem’s TR indicator lights to  
show that the software has taken control of the modem through the COM port.  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 6 – Troubleshooting  
Your communication software settings may not match the physical port to which the modem is connected.  
The serial cable might be plugged into the wrong connector—check your computer documentation to make  
sure. Or you might have selected a COM port in your software other than the one the modem is physically  
connected to—compare the settings in your software to the physical connection.  
If the modem is on, the cable is plugged into the correct port, the communication software is configured  
correctly, and you still don’t get an OK, the fault might be in the serial cable. Make sure it is firmly connected  
at both ends.  
Is this the first time you have used the cable? If so, it may not be wired correctly. Check the cable  
description on the packaging to make sure the cable is the right one for your computer.  
Peripheral expansion cards, such as sound and game cards, might include a serial port preconfigured as  
COM1 or COM2. The extra serial port, or the card itself, may use the same COM port, memory address, or  
interrupt request (IRQ) as your communication port. Be sure to disable any unused ports.  
Windows 9x: Right-click on My Computer, select Properties from the menu, click on the Device Manager  
tab, double-click on Ports, then double-click on the communication port your modem is connected to. In the  
port’s Properties sheet, click on the Resources tab to see the port’s input/output range and interrupt  
request. If another device is using the same address range or IRQ, it appears in the Conflicting Device  
List. Uncheck Use automatic settings to change the port’s settings so they do not conflict with the other  
device, or select the port the conflicting device is on and change it instead. If you need to open your  
computer to change switches or jumpers on the conflicting device, refer to the device’s documentation.  
Windows NT 4.0: To look for address or IRQ conflicts, click Start, Programs, Administrative Tools  
(Common), and Windows NT Diagnostics. In the Windows NT Diagnostics dialog box, click the  
Resources tab to see which input/output ranges and interrupt requests are in use. If you need to open your  
computer to change switches or jumpers on the conflicting device, refer to the device’s documentation.  
The serial port might be defective. If you have another serial port, install the modem on it, change the COM  
port setting in your software, and try again.  
The modem might have a problem beyond the scope of this user guide. If you have another Multi-Tech  
modem, try the other modem. If there is no problem with the other modem, call Technical Support for  
assistance.  
The Modem Cannot Connect When Dialing  
There can be several reasons the modem fails to make a connection. Possibilities include  
lack of a physical connection to the telephone line.  
a wrong dial tone.  
a busy signal.  
a wrong number.  
no modem at the other end.  
a faulty modem, computer, or software at the other end.  
incompatibility between modems  
poor line conditions.  
You can narrow the list of possibilities by using extended result codes. Extended result codes are enabled by default.  
If they have been disabled, include V1X4 in the modem’s initialization string, or in terminal mode enter ATV1X4 and  
press Enter. When you dial again, the modem reports the call’s progress.  
If the modem reports NO DIALTONE, check that the modem’s telephone line cable is connected to both the  
modem’s LINE jack (not the PHONE jack) and the telephone wall jack. If the cable looks secure, try  
replacing it. If that doesn’t work, the problem might be in your building’s telephone installation. To test the  
building installation, plug a telephone into your modem’s telephone wall jack and listen for a dial tone. If you  
hear a dial tone, your modem might be installed behind a corporate phone system (PBX) with an internal dial  
tone that sounds different from the normal dial tone. In that case, the modem might not recognize the dial  
tone and might treat it as an error. Check your PBX manual to see if you can change the internal dial tone. If  
you can’t, change your modem’s initialization string to replace X4 with X3, which will cause the modem to  
ignore dial tones.  
If the modem reports BUSY, the other number might be busy, in which case you should try again later.  
However, it might indicate that you have failed to add a 9, the prefix to the phone number if you must dial 9  
for an outside line.  
If you must dial 9 to get an outside line, the easiest way to dial it automatically is to include it in the modem’s  
dial prefix; e.g., ATDT9. Note the comma, which inserts a pause before the number is dialed. By inserting 9,  
into the dial prefix, you do not have to include it in each directory entry.  
To change the dial prefix in Windows HyperTerminal, select Connect from the Call menu, click Dialing  
Properties, and type 9 in the local and long distance boxes in How I dial from this location.  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 6 – Troubleshooting  
If there is no answer on the remote end, the modem reports NO CARRIER. You might have dialed a wrong  
number, and a person answered instead of a computer, or you might have dialed the correct number but the  
other computer or software was turned off or faulty. Check the number and try again, or try calling another  
system to make sure your modem is working. Also, try calling the number on your telephone. If you hear  
harsh sounds, then another modem is answering the call, and the modems might be having problems  
negotiating because of modem incompatibilities or line noise. Try connecting at a lower speed.  
Poor line conditions can affect the connection. When using V.34 or V.32 client-to-client connections in poor  
conditions, setting S38=0 may result in better performance.  
The Modem Disconnects While Online  
If you are not using Modem on Hold, Call Waiting can interrupt your connection when someone tries to call  
you. If you have Call Waiting service, disable it before each call. In most telephone areas in North America,  
you can disable Call Waiting by preceding the telephone number with *70 (but first check with your local  
telephone company).  
You can automatically disable Call Waiting by including the disabling code in the modem’s dial prefix (e.g.,  
ATDT*70, – note the comma, which inserts a pause before the number is dialed). To change the dial prefix  
in Windows HyperTerminal, select Connect from the Call menu, click Dialing Properties, check This  
location has Call Waiting, and select the correct code for your phone service.  
If you have extension phones on the same line as your modem, you or someone else can interrupt the  
connection by picking up another phone. If this is a frequent problem, disconnect the extension phones  
before using the modem, or install another phone line especially for the modem.  
Check for loose connections between the modem and the computer, the telephone jack, and AC power.  
You might have had a poor connection because of line conditions or the problem might have originated on  
the other end of the line. Try again.  
Your ISP might have hung up on you because of lack of activity on your part or because you exceeded your  
time limit for the day. Try again.  
Modem Cannot Connect When Answering  
The default DTR Control command (&D2) inhibits autoanswer. To enable autoanswer, change DTR Control  
to &D0, and make sure &Q0, &Q5, or &Q6 is also set. For more information, see the &D command in the  
AT Commands Reference Guide. For information on changing the modem’s default configuration, see  
“Install and Configure Your Software” in Chapter 2.  
Autoanswer might be disabled. Turn on autoanswer in your communications program or send the command  
ATS0=1 (ATS0=2 if you have Caller ID service) to your modem in terminal mode.  
File Transfer Is Slower Than It Should Be  
If you are using a slow transfer protocol, such as Xmodem, try Zmodem or Ymodem/G instead.  
Is your line noisy? If there is static on your line, the modem has to resend many blocks of data to insure  
accuracy. You must have a clean line for maximum speed.  
Are you downloading a compressed file with MNP 5 hardware compression enabled? Since hardware data  
compression cannot compress a file already compressed by an archiving program, the transfer can be  
marginally slower with data compression enabled than with it disabled.  
Does your Internet service provider (ISP) use the same 56K protocol as your modem? The default setting of  
your modem is to connect using either the V.92 or the V.90 protocol, depending on which one the ISP’s  
modem is using. If your ISP uses the V.90 protocol, the maximum speed you will be able to upload at is  
33,600 bps. Check with your ISP to see which protocols it supports.  
Are you trying to send a file to another client modem? If so, then your maximum possible connect speed is  
33,600 bps. You can upload at speeds up to 48,000 bps only when connected to an ISP that supports the  
V.92 protocol.  
Try entering the I11 command in online mode or the &V command in command mode to display information  
about the last connection, making a screen print of the connection statistics, and checking for parameters  
that might be unacceptable.  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 6 – Troubleshooting  
Data Is Being Lost  
If you are using data compression and a high speed serial port, set the serial port baud rate to two to six  
times the data rate.  
Make sure the flow control method you selected in software matches the method selected in the modem.  
Try entering the I11 command in online mode or the &V command in command mode to display information  
about the last connection, making a screen print of the connection statistics, and checking for parameters  
that might be unacceptable.  
There Are Garbage Characters on the  
Monitor  
Your computer and the remote computer might be set to different word lengths, stop bits, or parities. If you  
have connected at 8-N-1, try changing to 7-E-1, or vice-versa, using your communication software.  
You might be experiencing line noise. Enable error correction, if it is disabled, or hang up and call again; you  
might get a better connection the second time.  
At speeds above 2400 bps, the remote modem might not use the same transmission or error correction  
standards as your modem. Try connecting at a slower speed or disabling error correction. (With no error  
correction, however, line noise can cause garbage characters.)  
Try entering the I11 command in online mode or the &V command in command mode to display information  
about the last connection, making a screen print of the connection statistics, and checking for parameters  
that might be unacceptable.  
The Modem Doesn’t Work with Caller ID  
Caller ID information is transmitted between the first and second rings, so if autoanswer is turned off (S0=0)  
or if the modem is set to answer after only one ring (S0=1), the modem will not receive Caller ID information.  
Check your initialization string, and if necessary change it to set the modem to answer after the second ring  
(S0=2).  
Make sure that you have Caller ID service from your telephone company.  
Fax and Data Software Can’t Run at the Same  
Time  
Communication devices can be accessed by only one application at a time. In Windows 95 and higher, you  
can have data and fax communication applications open at the same time, but they cannot use the same  
modem at the same time.  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix A – Flash Upgrade  
Appendix A – Flash Upgrade  
Your modem is controlled by semi-permanent firmware, which is stored in flash memory. Multi-Tech's firmware is  
nonvolatile; that is, it remains stored in memory when the modem is turned off and can be upgraded as new features  
are added.  
Multi-Tech's Flash Wizard can be downloaded from Multi-Tech’s FTP site and is available on the MT5634IND CD.  
Use this Flash Wizard for upgrading your firmware. Documentation for using the Flash Wizard is included with the  
wizard.  
Flash Wizard Software for Windows: ftp://ftp.multitech.com/utilities/flashwizard/  
Flash Wizard Software for Linux: http://mtflashwiz.sourceforge.net/  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix B – Regulatory Compliance  
Appendix B – Regulatory Compliance  
Regulatory Compliance Statements  
EMC, Safety, and R&TTE Directive Compliance  
The CE mark is affixed to this product to confirm compliance with the following European Community  
Directives:  
Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of Member States  
relating to electromagnetic compatibility;  
and  
Council Directive 73/23/EEC of 19 February 1973 on the harmonization of the laws of Member States  
relating to electrical equipment designed for use within certain voltage limits;  
and  
Council Directive 1999/5/EC of 9 March on radio equipment and telecommunications terminal  
equipment and the mutual recognition of their conformity.  
International Modem Restrictions  
Some dialing and answering defaults and restrictions may vary for international modems. Changing settings  
may cause a modem to become non-compliant with national telecom requirements in specific countries.  
Also note that some software packages may have features or lack restrictions that may cause the modem to  
become non-compliant.  
Telecom Requirements for the United States  
FCC Part 15 Regulation  
This equipment has been tested and found to comply with the limits for a Class B digital device,  
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection  
against harmful interference in a residential installation. This equipment generates, uses, and can  
radiate radio frequency energy, and if not installed and used in accordance with the instructions, may  
cause harmful interference to radio communications. However, there is no guarantee that interference  
will not occur in a particular installation. If this equipment does cause harmful interference to radio or  
television reception, which can be determined by turning the equipment off and on, the user is  
encouraged to try to correct the interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Plug the equipment into an outlet on a circuit that is different from the one used by the receiver.  
Consult the dealer or an experienced radio/TV technician for help.  
This device complies with Part 15 of the FCC rules. Operation of this device is subject to the following  
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any  
interference that may cause undesired operation.  
WARNING – Changes or modifications to this unit not expressly approved by the party responsible for  
compliance could void the user’s authority to operate the equipment.  
Industry Canada  
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment  
Regulations.  
Cet appareil numérique de la classe B respecte toutes les exigences du Reglement Canadien sur le matériel  
brouilleur.  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix B – Regulatory Compliance  
New Zealand Telecom Warning Notice  
1. The grant of a Telepermit for any item of terminal equipment indicates only that Telecom has  
accepted that the item complies with minimum conditions for connection to its network. It indicates  
no endorsement of the product by Telecom, nor does it provide any sort of warranty. Above all, it  
provides no assurance that any item will work correctly in all respects with another item of  
Telepermitted equipment of a different make or model, nor does it imply that any product is  
compatible with all of Telecom’s network services.  
This equipment is not capable under all operating conditions of correct operating conditions of  
correct operation at the higher speed which it is designated. 33.6 kbps and 56 kbps connections  
are likely to be restricted to lower bit rates when connected to some PSTN implementations.  
Telecom will accept no responsibility should difficulties arise in such circumstances.  
2. Immediately disconnect this equipment should it become physically damaged, and arrange for its  
disposal or repair.  
3. This modem shall not be used in any manner which could constitute a nuisance to other Telecom  
customers.  
4. This device is equipped with pulse dialing, while the Telecom standard is DTMF tone dialing. There  
is no guarantee that Telecom lines will always continue to support pulse dialing.  
Use of pulse dialing, when this equipment is connected to the same line as other equipment, may  
give rise to 'bell tinkle' or noise and may also cause a false answer condition. Should such  
problems occur, the user should NOT contact the Telecom Faults Service.  
The preferred method of dialing is to use DTMF tones, as this is faster than pulse (decadic) dialing  
and is readily available on almost all New Zealand telephone exchanges.  
5. Warning Notice: No '111' or other calls can be made from this device during a mains power failure.  
6. This equipment may not provide for the effective hand-over of a call to another device connected to  
the same line.  
7. Some parameters required for compliance with Telecom’s Telepermit requirements are dependent  
on the equipment (PC) associated with this device. The associated equipment shall be set to  
operate within the following limits for compliance with Telecom’s Specifications:  
For repeat calls to the same number:  
There shall be no more than 10 call attempts to the same number within any 30 minute  
period for any single manual call initiation, and  
The equipment shall go on-hook for a period of not less than 30 seconds between the end  
of one attempt and the beginning of the next attempt.  
For automatic calls to different numbers:  
The equipment shall be set to ensure that automatic calls to different numbers are spaced  
such that there is no less than 5 seconds between the end of one call attempt and the  
beginning of another.  
8. For correct operation, total of the RN’s of all devices connected to a single line at any time should  
not exceed 5.  
South African Statement  
This modem must be used in conjunction with an approved surge protection device.  
Other  
The above country-specific examples do not cover all countries with specific regulations; they are included  
to show you how each country may differ. If you have trouble determining your own country's requirements,  
check with Multi-Tech's Technical Support for assistance.  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix C – Multi-Tech Warranty Statement and Product Repair  
Appendix C – Multi-Tech Warranty  
Statement and Product Repair  
Warranty  
Multi-Tech Systems, Inc., (hereafter “MTS”) warrants that its products will be free from defects in material or  
workmanship for a period of two, five, or ten years (depending on model) from date of purchase, or if proof of  
purchase is not provided, two, five, or ten years (depending on model) from date of shipment.  
MTS MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF  
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.  
This warranty does not apply to any products which have been damaged by lightning storms, water, or power surges  
or which have been neglected, altered, abused, used for a purpose other than the one for which they were  
manufactured, repaired by Customer or any party without MTS’s written authorization, or used in any manner  
inconsistent with MTS’s instructions.  
MTS’s entire obligation under this warranty shall be limited (at MTS’s option) to repair or replacement of any products  
which prove to be defective within the warranty period or, at MTS’s option, issuance of a refund of the purchase price.  
Defective products must be returned by Customer to MTS’s factory — transportation prepaid.  
MTS WILL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES, AND UNDER NO CIRCUMSTANCES WILL ITS  
LIABILITY EXCEED THE PRICE FOR DEFECTIVE PRODUCTS.  
Online Warranty Registration  
If you have access to the World Wide Web, you can register your Multi- Tech product online at the following URL:  
Product Repair  
Repair Procedures for U.S. and Canadian Customers  
In the event that service is required, products may be shipped, freight prepaid, to our Mounds View, Minnesota  
factory:  
Multi-Tech Systems, Inc.  
2205 Woodale Drive  
Mounds View, MN 55112  
Attn: Repairs, Serial # ____________  
A Returned Materials Authorization (RMA) is not required. Return shipping charges (surface) will be paid by MTS  
to destinations in U.S. and Canada.  
Please include, inside the shipping box, a description of the problem, a return shipping address (must have street  
address, not P.O. Box), your telephone number, and if the product is out of warranty, a check or purchase order  
for repair charges.  
For out of warranty repair charges, go to www.multitech.com/DOCUMENTS/Company/warranty/  
Extended two-year overnight replacement service agreements are available for selected products. Please call  
MTS customer service at (888) 288-5470 or visit our web site at www.multitech.com/PARTNERS/Programs/orc/  
for details on rates and coverage’s.  
Please direct your questions regarding technical matters, product configuration, verification that the product is  
defective, etc., to our Technical Support department at (800) 972-2439 or email [email protected]. Please  
direct your questions regarding repair expediting, receiving, shipping, billing, etc., to our Repair Accounting  
department at (800) 328-9717 or (763) 717-5631, or email [email protected].  
Repairs for damages caused by lightning storms, water, power surges, incorrect installation, physical abuse, or  
user-caused damages are billed on a time-plus-materials basis.  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix C – Warranty and Service  
Repair Procedures for International Customers (Outside U.S.A. and Canada)  
Your original point of purchase Reseller may offer the quickest and most economical repair option for your Multi-  
Tech product. You may also contact any Multi-Tech sales office for information about the nearest distributor or  
other repair service for your Multi-Tech product. The Multi-Tech sales office directory is available at  
In the event that factory service is required, products may be shipped, freight prepaid to our Mounds View,  
Minnesota factory. Recommended international shipment methods are via Federal Express, UPS or DHL courier  
services, or by airmail parcel post; shipments made by any other method will be refused. A Returned Materials  
Authorization (RMA) is required for products shipped from outside the U.S.A. and Canada. Please contact us for  
return authorization and shipping instructions on any International shipments to the U.S.A. Please include, inside  
the shipping box, a description of the problem, a return shipping address (must have street address, not P.O.  
Box), your telephone number, and if the product is out of warranty, a check drawn on a U.S. bank or your  
company’s purchase order for repair charges. Repaired units shall be shipped freight collect, unless other  
arrangements are made in advance.  
Please direct your questions regarding technical matters, product configuration, verification that the product is  
defective, etc., to our Technical Support department nearest you or email [email protected]. When calling  
the U.S., please direct your questions regarding repair expediting, receiving, shipping, billing, etc., to our Repair  
Accounting department at +(763) 717-5631 in the U.S.A., or email [email protected].  
Repairs for damages caused by lightning storms, water, power surges, incorrect installation, physical abuse, or  
user-caused damages are billed on a time-plus-materials basis.  
Repair Procedures for International Distributors  
International distributors should contact their MTS International sales representative for information about the  
repairs for their Multi-Tech product.  
Please direct your questions regarding technical matters, product configuration, verification that the product is  
defective, etc., to our International Technical Support department at +(763)717-5863. When calling the U.S.,  
please direct your questions regarding repair expediting, receiving, shipping, billing, etc., to our Repair  
Accounting department at +(763) 717-5631 in the U.S.A. or email [email protected].  
Repairs for damages caused by lightning storms, water, power surges, incorrect installation, physical abuse, or  
user-caused damages are billed on a time-plus-materials basis.  
Replacement Parts  
SupplyNet, Inc. can supply you with replacement power supplies, cables, and connectors for selected Multi-Tech  
products. You can place an order with SupplyNet via mail, phone, fax, or the Internet at the following addresses:  
Mail:  
SupplyNet, Inc.  
614 Corporate Way  
Valley Cottage, NY 10989  
800 826-0279  
Phone:  
Fax:  
914 267-2420  
Email:  
Internet:  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
Index  
LED Indicators......................................................7, 19  
Lost Data..................................................................22  
A
AC Power Connection..............................................10  
AC power connections .............................................10  
AT commands..........................................................13  
Autoanswer ..............................................................21  
M
Manufacturing Information .........................................6  
MNP 5 Data Compression .......................................21  
modem driver installation .........................................11  
C
N
Call Waiting..............................................................21  
Callback Security .....................................................15  
Callback Security Message Parity............................16  
Callback Security on and off ....................................15  
Callback Security Password.....................................16  
Callback Security Phone Numbers...........................16  
Caller ID...................................................................21  
Canadian Regulations..............................................24  
Carrier Detect.............................................................7  
Configure the Modem for Your Country/Region .......11  
Configure the Modem Using AT Commands............11  
Configure the Modem Using the Global Wizard.......11  
Connecting the modem............................................10  
New Zealand Telecom Warning Notice....................25  
O
Ordering Replacement Parts....................................27  
P
Package Contents......................................................5  
Phone Line Connection............................................10  
PhoneTools Program ...............................................12  
Power Connection....................................................10  
Power Consumption...................................................7  
Power LED.................................................................7  
Power Requirements..................................................7  
Protocols..................................................................21  
D
Data Interface.............................................................6  
Data Rates.................................................................6  
DC Power Connection..............................................10  
DC power connections.............................................10  
driver installation ......................................................11  
DTR (Data Terminal Ready) Control command .......21  
R
Receive Data..............................................................7  
Register your modem...............................................26  
Reliability....................................................................6  
Remote Configuration ..............................................14  
Escape Character.................................................14  
Repair ......................................................................26  
Replacement Parts...................................................27  
RS-232 9-Pin Connector............................................7  
RS-232 Connection..................................................10  
E
EMC Safety Approvals...............................................6  
EMC, Safety, and R&TTE Directive Compliance......24  
F
S
Fax Rates...................................................................6  
FCC Regulations......................................................24  
Features.....................................................................6  
Firmware Upgrade ...................................................23  
Flash Upgrade..........................................................23  
Flash Wizard ............................................................23  
Front Panel ..............................................................19  
safety .........................................................................5  
Safety Certifications ...................................................6  
Serial Cable .............................................................20  
South African Statement, Regulations .....................25  
Specifications.............................................................6  
T
G
Terminal Ready..........................................................7  
Testing the Modem  
Self-Test...............................................................19  
Transmit Data.............................................................7  
Troubleshooting .......................................................19  
Garbage Characters.................................................22  
Global Configuration ................................................11  
Global Wizard...........................................................11  
I
U
Indicators .................................................................19  
Install Data Communications Software ....................12  
Installation..................................................................9  
installing the modem driver ......................................11  
International Modem Restrictions.............................24  
Upgrade Firmware ...................................................23  
W
Warranty ..................................................................26  
L
Leased-Line Operation...............................................8  
Multi-Tech Systems, Inc. MT5634IND User Guide (S000369A)  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Milwaukee Drill 5380 21 User Manual
Mountain Buggy Baby Carrier Buggy Range Outside Cove User Manual
MTD Snow Blower 600 Series User Manual
MTD Snow Blower E173 User Manual
Multi Tech Systems Network Card MT2834ZDX User Manual
National Instruments DJ Equipment NI LabVIEW User Manual
Nilfisk ALTO Pressure Washer 2 19 X User Manual
Omega Speaker Systems Stud Sensor CY670 Series User Manual
Panasonic Cell Phone EB GD96 User Manual
Patton electronic Switch 03340D4 001 User Manual