OM-808
081 904F
January 1997
Processes
TIG (GTAW) Welding
Stick (SMAW) Welding
Description
Multiple Operator Resistance Grids
(MOG), Racks, And Remote Controls
MOG-250/250, MOG-300, MOG-350/350,
MOG-400, MOG-Pak, And RGC Controls
Visit our website at
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
The following terms are
used interchangeably
throughout this manual:
TIG = GTAW
SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols for Installation, Operation, and Maintenance . . . . . . . . . . . . . . . . . . . . . .
1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 1 – CONSIGNES DE SECURITE – LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . .
1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
3
3
4
5
5
5
Stick = SMAW
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
8
8
9
9
9
1-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 – SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Resistance Grid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Grid Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 – INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3-1. Typical Multiple Operator System Component Relationships . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Selecting A Location And Moving Resistance Grid Or Multi-Grid Rack . . . . . . . . . . . . . . . . .
3-3. Weld Input/Output Cables For Resistance Grid (Dual Model Shown) . . . . . . . . . . . . . . . . . . .
3-4. Weld Input/Output Cables For Multi-Grid Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-5. Female Camlok Connector Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-6. Male Camlok Connector Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-7. Weld Cable Size* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-8. Optional Remote Receptacle Information And Connections . . . . . . . . . . . . . . . . . . . . . . . . . .
10
11
12
13
14
14
15
15
SECTION 4 – OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4-1. Controls (Dual Model Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Safety Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Work Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Optional Polarity Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. Amperage Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-6. Optional Remote Grid Amperage Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7. Paralleling Switch (Dual Models Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-8. Sequence Of Shielded Metal Arc Welding (SMAW) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-9. Sequence Of Gas Tungsten Arc Welding (GTAW) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
16
17
17
18
19
19
20
20
SECTION 5 – MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Fuse Link Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-3. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
21
21
SECTION 6 – ELECTRICAL DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
SECTION 7 – PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
OPTIONS AND ACCESSORIES
WARRANTY
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING
som _nd_5/97
1-1. Symbol Usage
Means Warning! Watch Out! There are possible hazards
with this procedure! The possible hazards are shown in
the adjoining symbols.
This group of symbols means Warning! Watch Out! possible
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.
Consult symbols and related instructions below for necessary actions
to avoid the hazards.
Y
Marks a special safety message.
. Means “Note”; not safety related.
1-2. Arc Welding Hazards
Y
The symbols shown below are used throughout this manual to
call attention to and identify possible hazards. When you see
the symbol, watch out, and follow the related instructions to
avoid the hazard. The safety information given below is only
a summary of the more complete safety information found in
the Safety Standards listed in Section 1-4. Read and follow all
Safety Standards.
D
D
D
If earth grounding of the workpiece is required, ground it directly
with a separate cable – do not use work clamp or work cable.
Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
D
D
D
Wear a safety harness if working above floor level.
Keep all panels and covers securely in place.
Y
Y
Only qualified persons should install, operate, maintain, and
repair this unit.
During operation, keep everybody, especially children, away.
Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
D
D
Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
ELECTRIC SHOCK can kill.
Do not connect more than one electrode or work cable to any
single weld output terminal.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
SIGNIFICANT DC VOLTAGE exists after removal of
input power on inverters.
live when power is on. In semiautomatic or automatic wire welding, the
wire, wire reel, drive roll housing, and all metal parts touching the
welding wire are electrically live. Incorrectly installed or improperly
groundedequipment is a hazard.
D
Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.
D
D
D
Do not touch live electrical parts.
Wear dry, hole-free insulating gloves and body protection.
FUMES AND GASES can be hazardous.
Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
D
Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D
D
Keep your head out of the fumes. Do not breathe the fumes.
D
D
Use AC output ONLY if required for the welding process.
If inside, ventilate the area and/or use exhaust at the arc to remove
welding fumes and gases.
If AC output is required, use remote output control if present on
unit.
D
D
If ventilation is poor, use an approved air-supplied respirator.
D
Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
Read the Material Safety Data Sheets (MSDSs) and the
manufacturer’s instructions for metals, consumables, coatings,
cleaners, and degreasers.
D
D
Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.
D
Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watch-
person nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breath-
ing air is safe.
Always verify the supply ground – check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
groundedreceptacle outlet.
D
D
Do not weld in locations near degreasing, cleaning, or spraying op-
erations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
D
D
When making input connections, attach proper grounding conduc-
tor first – double-check connections.
Frequently inspect input power cord for damage or bare wiring –
replace cord immediately if damaged – bare wiring can kill.
Do not weld on coated metals, such as galvanized, lead, or
cadmiumplated steel, unless the coating is removed from the weld
area, the area is well ventilated, and if necessary, while wearing an
air-suppliedrespirator. The coatings and any metals containing
these elements can give off toxic fumes if welded.
D
D
D
Turn off all equipment when not in use.
Do not use worn, damaged, undersized, or poorly spliced cables.
Do not drape cables over your body.
OM-808 Page 1
Download from Www.Somanuals.com. All Manuals Search And Download.
ARC RAYS can burn eyes and skin.
BUILDUP OF GAS can injure or kill.
D
D
Shut off shielding gas supply when not in use.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
Always ventilate confined spaces or use
approved air-supplied respirator.
D
Wear a welding helmet fitted with a proper shade of filter to protect
your face and eyes when welding or watching (see ANSI Z49.1
and Z87.1 listed in Safety Standards).
HOT PARTS can cause severe burns.
D
D
D
Wear approved safety glasses with side shields under your
helmet.
D
D
Do not touch hot parts bare handed.
Use protective screens or barriers to protect others from flash and
glare; warn others not to watch the arc.
Allow cooling period before working on gun or
torch.
Wear protective clothing made from durable, flame-resistant mate-
rial (leather and wool) and foot protection.
MAGNETIC FIELDS can affect pacemakers.
WELDING can cause fire or explosion.
D
D
Pacemaker wearers keep away.
Wearers should consult their doctor before
going near arc welding, gouging, or spot
welding operations.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
NOISE can damage hearing.
D
D
D
Protect yourself and others from flying sparks and hot metal.
Do not weld where flying sparks can strike flammable material.
Noise from some processes or equipment can
damagehearing.
Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D
Wear approved ear protection if noise level is
high.
D
Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D
D
Watch for fire, and keep a fire extinguisher nearby.
CYLINDERS can explode if damaged.
Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
Shielding gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
D
D
Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock and fire hazards.
D
D
Protect compressed gas cylinders from excessive heat, mechani-
cal shocks, slag, open flames, sparks, and arcs.
Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D
D
Do not use welder to thaw frozen pipes.
Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D
D
D
D
D
Keep cylinders away from any welding or other electrical circuits.
Never drape a welding torch over a gas cylinder.
D
D
Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
Never allow a welding electrode to touch any cylinder.
Never weld on a pressurized cylinder – explosion will result.
Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
Use only correct shielding gas cylinders, regulators, hoses, and fit-
tings designed for the specific application; maintain them and
associated parts in good condition.
FLYING METAL can injure eyes.
D
D
Turn face away from valve outlet when opening cylinder valve.
D
Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D
Read and follow instructions on compressed gas cylinders,
associated equipment, and CGA publication P-1 listed in Safety
Standards.
D
Wear approved safety glasses with side
shields even under your welding helmet.
OM-808 Page 2
Download from Www.Somanuals.com. All Manuals Search And Download.
1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.
MOVING PARTS can cause injury.
D
Do not install or place unit on, over, or near
combustiblesurfaces.
D
D
Keep away from moving parts such as fans.
Keep all doors, panels, covers, and guards
closed and securely in place.
D
Do not install unit near flammables.
D
Do not overload building wiring – be sure power supply system is
properly sized, rated, and protected to handle this unit.
FALLING UNIT can cause injury.
H.F. RADIATION can cause interference.
D
D
D
Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D
High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communicationsequipment.
Use equipment of adequate capacity to lift and
support unit.
D
Have only qualified persons familiar with
electronic equipment perform this installation.
If using lift forks to move unit, be sure forks are
long enough to extend beyond opposite side of
unit.
D
D
The user is responsible for having a qualified electrician prompt-
ly correct any interference problem resulting from the installa-
tion.
If notified by the FCC about interference, stop using the
equipmentat once.
OVERUSE can cause OVERHEATING
D
D
Allow cooling period; follow rated duty cycle.
D
D
Have the installation regularly checked and maintained.
Reduce current or reduce duty cycle before
starting to weld again.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
D
Do not block or filter airflow to unit.
STATIC (ESD) can damage PC boards.
D
D
Put on grounded wrist strap BEFORE handling
boards or parts.
ARC WELDING can cause interference.
Use proper static-proof bags and boxes to
store, move, or ship PC boards.
D
Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
MOVING PARTS can cause injury.
D
Be sure all equipment in the welding area is
electromagneticallycompatible.
D
D
Keep away from moving parts.
Keep away from pinch points such as drive
rolls.
D
D
D
D
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive elec-
tronic equipment.
WELDING WIRE can cause injury.
Be sure this welding machine is installed and grounded
according to this manual.
D
D
Do not press gun trigger until instructed to do
so.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
1-4. Principal Safety Standards
Safety in Welding and Cutting, ANSI Standard Z49.1, from American
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Safety and Health Standards, OSHA 29 CFR 1910, from Superinten-
dent of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Code for Safety in Welding and Cutting, CSA Standard W117.2, from
Canadian Standards Association, Standards Sales, 178 Rexdale
Boulevard, Rexdale, Ontario, Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face
Protection, ANSI Standard Z87.1, from American National Standards
Institute, 1430 Broadway, New York, NY 10018.
Recommended Safe Practices for the Preparation for Weldingand Cut-
ting of Containers That Have Held Hazardous Substances, American
Welding Society Standard AWS F4.1, from American Welding Society,
550 N.W. LeJeune Rd, Miami, FL 33126
NationalElectrical Code, NFPA Standard 70, from National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.
Cutting And Welding Processes, NFPA Standard 51B, from National
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
OM-808 Page 3
Download from Www.Somanuals.com. All Manuals Search And Download.
1-5. EMF Information
Considerations About Welding And The Effects Of Low Frequency
Electric And Magnetic Fields
1. Keep cables close together by twisting or taping them.
2. Arrange cables to one side and away from the operator.
3. Do not coil or drape cables around your body.
Welding current, as it flows through welding cables, will cause electro-
magnetic fields. There has been and still is some concern about such
fields. However, after examining more than 500 studies spanning 17
years of research, a special blue ribbon committee of the National
Research Council concluded that: “The body of evidence, in the
committee’s judgment, has not demonstrated that exposure to power-
frequency electric and magnetic fields is a human-health hazard.”
However, studies are still going forth and evidence continues to be
examined.Until the final conclusions of the research are reached, you
may wish to minimize your exposure to electromagnetic fields when
welding or cutting.
4. Keep welding power source and cables as far away from opera-
tor as practical.
5. Connect work clamp to workpiece as close to the weld as possi-
ble.
About Pacemakers:
To reduce magnetic fields in the workplace, use the following
procedures:
Pacemaker wearers consult your doctor first. If cleared by your doctor,
then following the above procedures is recommended.
OM-808 Page 4
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 1 – CONSIGNES DE SECURITE – LIRE AVANT
UTILISATION
som _nd_fre 5/97
1-1. Signification des symboles
SignifieMise en garde ! Soyez vigilant ! Cette procédure
présente des risques de danger ! Ceux-ci sont identifiés
par des symboles adjacents aux directives.
Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des
risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN
MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles
et aux directives ci-dessous afin de connaître les mesures à prendre pour
éviter tout danger.
Y
Identifie un message de sécurité particulier.
. Signifie NOTA ; n’est pas relatif à la sécurité.
1-2. Dangers relatifs au soudage à l’arc
Y
Les symboles présentés ci-après sont utilisés tout au long du
présent manuel pour attirer votre attention et identifier les risques
de danger. Lorsque vous voyez un symbole, soyez vigilant et
suivez les directives mentionnées afin d’éviter tout danger. Les
consignes de sécurité présentées ci-après ne font que résumer
l’information contenue dans les normes de sécurité énumérées
à la section 1-4. Veuillez lire et respecter toutes ces normes de
sécurité.
D
D
Ne pas toucher l’électrode quand on est en contact avec la pièce, la
terre ou une électrode provenant d’une autre machine.
N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-le-
champ les pièces endommagées. Entretenir l’appareil conformément
à ce manuel.
D
D
D
Porter un harnais de sécurité quand on travaille en hauteur.
Maintenir solidement en place tous les panneaux et capots.
Y
Y
L’installation, l’utilisation, l’entretien et les réparations ne doi-
vent être confiés qu’à des personnes qualifiées.
Fixer le câble de retour de façon à obtenir un bon contact métal-métal
avec la pièce à souder ou la table de travail, le plus près possible de la
soudure.
Au cours de l’utilisation, tenir toute personne à l’écart et plus par-
ticulièrement les enfants.
D
Isoler la pince de masse quand pas mis à la pièce pour éviter le contact
avec tout objet métallique.
UN CHOC ÉLECTRIQUE peut tuer.
Un simple contact avec des pièces électriques peut
provoquer une électrocution ou des blessures graves.
L’électrode et le circuit de soudage sont sous tension
dès que l’appareil est sur ON. Le circuit d’entrée et les
circuits internes de l’appareil sont également sous
Il y a DU COURANT CONTINU IMPORTANT dans les
convertisseurs après la suppression de l’alimenta-
tion électrique.
D
Arrêter les convertisseurs, débrancher le courant électrique, et dé-
charger les condensateurs d’alimentation selon les instructions
indiquées dans la partie entretien avant de toucher les pièces.
tension à ce moment-là. En soudage semi-automatique ou automatique,
le fil, le dévidoir, le logement des galets d’entraînement et les pièces
métalliques en contact avec le fil de soudage sont sous tension. Des
matériels mal installés ou mal mis à la terre présentent un danger.
D
D
Ne jamais toucher les pièces électriques sous tension.
Porter des gants et des vêtements de protection secs ne comportant
pas de trous.
LES FUMÉES ET LES GAZ peuvent
D
S’isoler de la pièce et de la terre au moyen de tapis ou d’autres
moyens isolants suffisamment grands pour empêcher le contact phy-
sique éventuel avec la pièce ou la terre.
Ne pas se servir de source électrique àcourant électrique dans les zones
humides, dans les endroits confinés ou là où on risque de tomber.
être dangereux.
Le soudage génère des fumées et des gaz. Leur
D
D
D
D
inhalation peut être dangereux pour votre santé.
D
Eloigner votre tête des fumées. Ne pas respirer
Se servir d’une source électrique àcourant électrique UNIQUEMENT si le
procédé de soudage le demande.
les fumées.
D
A l’intérieur, ventiler la zone et/ou utiliser un échappement au niveau
de l’arc pour l’évacuation des fumées et des gaz de soudage.
Si la ventilation est insuffisante, utiliser un respirateur à alimenta-
tion d’air homologué.
Lire les spécifications de sécurité des matériaux (MSDSs) et les
instructions du fabricant concernant les métaux, les consomma-
bles, les revêtements, les nettoyants et les dégraisseurs.
Travailler dans un espace fermé seulement s’il est bien ventilé ou en
portant un respirateur à alimentation d’air. Demander toujours à un
surveillant dûment formé de se tenir à proximité. Des fumées et des
gaz de soudage peuvent déplacer l’air et abaisser le niveau d’oxy-
gène provoquant des blessures ou des accidents mortels. S’assu-
rer que l’air de respiration ne présente aucun danger.
Si l’utilisation d’une source électrique àcourant électrique s’avère néces-
saire, se servir de la fonction de télécommande si l’appareil en est équipé.
D
D
Couper l’alimentation ou arrêter le moteur avant de procéder à l’instal-
lation, à la réparation ou à l’entretien de l’appareil. Déverrouiller
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de
sécurité).
Installer et mettre à la terre correctement cet appareil conformément à
son manuel d’utilisation et aux codes nationaux, provinciaux et
municipaux.
Toujours vérifier la terre du cordon d’alimentation – Vérifier et s’assu-
rer que le fil de terre du cordon d’alimentation est bien raccordé à la
borne de terre du sectionneur ou que la fiche du cordon est raccordée
à une prise correctement mise à la terre.
D
D
D
D
D
Ne pas souder dans des endroits situés à proximité d’opérations de
dégraissage, de nettoyage ou de pulvérisation. La chaleur et les
rayons de l’arc peuvent réagir en présence de vapeurs et former des
gaz hautement toxiques et irritants.
Ne pas souder des métaux munis d’un revêtement, tels que l’acier
galvanisé, plaqué en plomb ou au cadmium à moins que le revête-
ment n’ait été enlevé dans la zone de soudure, que l’endroit soit bien
ventilé, et si nécessaire, en portant un respirateur à alimentation
d’air. Les revêtements et tous les métaux renfermant ces éléments
peuvent dégager des fumées toxiques en cas de soudage.
D
D
En effectuant les raccordements d’entrée fixer d’abord le conducteur
de mise à la terre approprié et contre-vérifier les connexions.
Vérifier fréquemment le cordon d’alimentation pour voir s’il n’est pas
endommagé ou dénudé – remplacer le cordon immédiatement s’il est
endommagé – un câble dénudé peut provoquer une électrocution.
Mettre l’appareil hors tension quand on ne l’utilise pas.
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffi-
sante ou mal épissés.
D
D
D
D
Ne pas enrouler les câbles autour du corps.
Si la pièce soudée doit être mise à la terre, le faire directement avec un
câble distinct – ne pas utiliser le connecteur de pièce ou le câble de
retour.
OM-808 Page 5
Download from Www.Somanuals.com. All Manuals Search And Download.
LES RAYONS DE L’ARC peuvent pro-
voquer des brûlures dans les yeux et
sur la peau.
LES ACCUMULATIONS DE GAZ ris-
quent de provoquer des blessures ou
même la mort.
Le rayonnement de l’arc du procédé de soudage
génère des rayons visibles et invisibles intenses
(ultraviolets et infrarouges) susceptibles de provoquer
des brûlures dans les yeux et sur la peau. Des étincelles sont projetées
pendant le soudage.
D
Fermer l’alimentation du gaz protecteur en cas de
non utilisation.
D
Veiller toujours à bien aérer les espaces confinés ou se servir d’un respi-
rateur d’adduction d’air homologué.
D
Porter un casque de soudage muni d’un écran de filtre approprié pour
protéger votre visage et vos yeux pendant le soudage ou pour regar-
der (voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).
DES PIÈCES CHAUDES peuvent pro-
voquer des brûlures graves.
D
D
Porter des protections approuvés pour les oreilles si le niveau sondre est
trop élevé.
Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair
et de l’éblouissement; demander aux autres personnes de ne pas re-
garder l’arc.
Porter des vêtements de protection constitué dans une matière dura-
ble, résistant au feu (cuir ou laine) et une protection des pieds.
D
D
Ne pas toucher des parties chaudes à mains nues
Prévoir une période de refroidissement avant
d’utiliser le pistolet ou la torche.
D
LE SOUDAGE peut provoquer un
incendie ou une explosion.
Le soudage effectué sur des conteneurs fermés tels
que des réservoirs, tambours ou des conduites peut
provoquer leur éclatement. Des étincelles peuvent être
projetées de l’arc de soudure. La projection d’étincel-
LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
D
D
Porteurs de stimulateur cardiaque, restez à distance.
Les porteurs d’un stimulateur cardiaque doivent
d’abord consulter leur médecin avant de s’approcher
des opérations de soudage à l’arc, de gougeage ou
de soudage par points.
les, des pièces chaudes et des équipements chauds peut provoquer des
incendies et des brûlures. Le contact accidentel de l’électrode avec des
objets métalliques peut provoquer des étincelles, une explosion, un
surchauffement ou un incendie. Avant de commencer le soudage, vérifier
et s’assurer que l’endroit ne présente pas de danger.
D
D
D
Se protéger et d’autres personnes de la projection d’étincelles et de
LE BRUIT peut affecter l’ouïe.
métal chaud.
Ne pas souder dans un endroit là où des étincelles peuvent tomber sur
des substances inflammables.
Le bruit des processus et des équipements peut affecter
l’ouïe.
Déplacer toutes les substances inflammables à une distance de 10,7
m de l’arc de soudage. En cas d’impossibilité les recouvrir soigneuse-
ment avec des protections homologués.
Des étincelles et des matériaux chauds du soudage peuvent facile-
ment passer dans d’autres zones en traversant de petites fissures et
des ouvertures.
D
Porter des protections approuvés pour les oreilles si
le niveau sondre est trop élevé.
D
D
D
D
Surveiller tout déclenchement d’incendie et tenir un extincteur à proxi-
Si des BOUTEILLES sont endomma-
gées, elles pourront exploser.
mité.
Le soudage effectué sur un plafond, plancher, paroi ou séparation
peut déclencher un incendie de l’autre côté.
Des bouteilles de gaz protecteur contiennent du gaz
sous haute pression. Si une bouteille est endomma-
gée, elle peut exploser. Du fait que les bouteilles de gaz
font normalement partie du procédé de soudage, les
Ne pas effectuer le soudage sur des conteneurs fermés tels que des
réservoirs, tambours, ou conduites, à moins qu’ils n’aient été prépa-
rés correctement conformément à AWS F4.1 (voir les normes de
sécurité).
Brancher le câble sur la pièce le plus près possible de la zone de sou-
dage pour éviter le transport du courant sur une longue distance par
des chemins inconnus éventuels en provoquant des risques d’élec-
trocution et d’incendie.
Ne pas utiliser le poste de soudage pour dégeler des conduites ge-
lées.
En cas de non utilisation, enlever la baguette d’électrode du porte-
électrode ou couper le fil à la pointe de contact.
Porter des vêtements de protection dépourvus d’huile tels que des
gants en cuir, une chemise en matériau lourd, des pantalons sans re-
vers, des chaussures hautes et un couvre chef.
Avant de souder, retirer toute substance combustible de vos poches
telles qu’un allumeur au butane ou des allumettes.
manipuler avec précaution.
D
D
D
D
Protéger les bouteilles de gaz comprimé d’une chaleur excessive,
des chocs mécaniques, du laitier, des flammes ouvertes, des étin-
celles et des arcs.
Placer les bouteilles debout en les fixant dans un support stationnai-
re ou dans un porte-bouteilles pour les empêcher de tomber ou de
se renverser.
Tenir les bouteilles éloignées des circuits de soudage ou autres cir-
cuits électriques.
Ne jamais placer une torche de soudage sur une bouteille à gaz.
Une électrode de soudage ne doit jamais entrer en contact avec une
D
D
D
D
D
bouteille.
D
D
D
Ne jamais souder une bouteille pressurisée – risque d’explosion.
Utiliser seulement des bouteilles de gaz protecteur, régulateurs,
tuyaux et raccords convenables pour cette application spécifique;
les maintenir ainsi que les éléments associés en bon état.
DES PARTICULES VOLANTES
peuvent blesser les yeux.
D
D
D
Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la
bouteille.
Maintenir le chapeau de protection sur la soupape, sauf en cas d’uti-
lisation ou de branchement de la bouteille.
Lire et suivre les instructions concernant les bouteilles de gaz com-
primé, les équipements associés et les publications P-1 CGA énu-
mérées dans les normes de sécurité.
D
Le soudage, l’écaillement, le passage de la pièce
à la brosse en fil de fer, et le meulage génèrent
des étincelles et des particules métalliques vo-
lantes. Pendant la période de refroidissement des soudures, elles ris-
quent de projeter du laitier.
D
Porter des lunettes de sécurité avec écrans latéraux ou un écran facial.
OM-808 Page 6
Download from Www.Somanuals.com. All Manuals Search And Download.
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
et la maintenance
Risque D’INCENDIE OU
D’EXPLOSION.
DES ORGANES MOBILES peuvent
provoquer des blessures.
D
Ne pas placer l’appareil sur, au-dessus ou à proxi-
mité de surfaces infllammables.
D
D
Rester à l’écart des organes mobiles comme le
ventilateur.
Maintenir fermés et fixement en place les portes,
panneaux, recouvrements et dispositifs de
protection.
D
D
Ne pas installer l’appareil à proximité de produits inflammables
Ne pas surcharger l’installation électrique – s”assurer que l’alimen-
tation est correctement dimensionné et protégé avant de mettre
l’appareil en service.
LE RAYONNEMENT HAUTE FRÉ-
QUENCE (H.F.) risque de provoquer
des interférences.
LA CHUTE DE L’APPAREIL peut
blesser.
D
Le rayonnement haute frequence peut provoquer
des interférences avec les équipements de ra-
dio–navigationet de communication, les services
de sécurité et les ordinateurs.
D
D
Utiliser l’anneau de levage uniquement pour sou-
lever l’appareil, NON PAS les chariot, les bouteil-
les de gaz ou tout autre accessoire.
D
Demander seulement à des personnes qualifiées familiarisées
avec des équipements électroniques de faire fonctionner l’installa-
tion.
L’utilisateur est tenu de faire corriger rapidement par un électricien
qualifié les interférences résultant de l’installation.
Utiliser un engin d’une capacité appropriée pour
soulever l’appareil.
D
En utilisant des fourches de levage pour déplacer l’unité, s’assurer
que les fourches sont suffisamment longues pour dépasser du côté
opposé de l’appareil.
D
D
Si le FCC signale des interférences, arrêter immédiatement l’appa-
reil.
L’EMPLOI EXCESSIF peut
SURCHAUFFER L’ÉQUIPEMENT.
D
D
Effectuer régulièrement le contrôle et l’entretien de l’installation.
Maintenir soigneusement fermés les portes et les panneaux des
sources de haute fréquence, maintenir les éclateurs à une distance
correcte et utiliser une terre et et un blindage pour réduire les interfé-
rences éventuelles.
D
D
Prévoir une période de refroidissement, respec-
ter le cycle opératoire nominal.
Réduire le courant ou le cycle opératoire avant de
recommancer le soudage.
LE SOUDAGE À L’ARC risque de
D
Ne pas obstruer les passages d’air du poste.
provoquer des interférences.
LES CHARGES ÉLECTROSTATI-
QUES peuvent endommager les cir-
cuits imprimés.
D
L’énergie électromagnétique risque de provoquer
des interférences pour l’équipement électronique
sensible tel que les ordinateurs et l’équipement
commandé par ordinateur tel que les robots.
D
D
Veiller à ce que tout l’équipement de la zone de soudage soit com-
D
D
Établir la connexion avec la barrette de terre
patible électromagnétiquement.
avant de manipuler des cartes ou des pièces.
Pour réduire la possibilité d’interférence, maintenir les câbles de
soudage aussi courts que possible, les grouper, et les poser aussi
bas que possible (ex. par terre).
Veiller à souder à une distance de 100 mètres de tout équipement
électronique sensible.
Veiller à ce que ce poste de soudage soit posé et mis à la terre
conformément à ce mode d’emploi.
En cas d’interférences après avoir pris les mesures précédentes, il
incombe à l’utilisateur de prendre des mesures supplémentaires tel-
les que le déplacement du poste, l’utilisation de câbles blindés, l’uti-
lisation de filtres de ligne ou la pose de protecteurs dans la zone de
travail.
Utiliser des pochettes et des boîtes antistatiques
pour stocker, déplacer ou expédier des cartes de
circuits imprimes.
D
D
D
DES ORGANES MOBILES peuvent
provoquer des blessures.
D
D
Ne pas s’approcher des organes mobiles.
Ne pas s’approcher des points de coincement
tels que des rouleaux de commande.
LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
LES FILS DE SOUDAGE peuvent pro-
voquer des blessures.
D
D
Porteurs de stimulateur cardiaque, restez à dis-
D
D
Ne pas appuyer sur la gachette avant d’en avoir
reçu l’instruction.
tance.
Les porteurs d’un stimulateur cardiaque doivent
d’abord consulter leur médecin avant de s’appro-
cher des opérations de soudage à l’arc, de gou-
geage ou de soudage par points.
Ne pas diriger le pistolet vers soi, d’autres person-
nes ou toute pièce mécanique en engageant le fil
de soudage.
OM-808 Page 7
Download from Www.Somanuals.com. All Manuals Search And Download.
1-4. Principales normes de sécurité
Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Wel-
ding Society, 550 N.W. Lejeune Rd, Miami FL 33126
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de la Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent
of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Règles de sécurité en soudage, coupage et procédés connexes, norme
CSA W117.2, de l’Association canadienne de normalisation, vente de
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.
RecommendedSafe Practice for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances, norme AWS
F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL
33126
Safe Practices For Occupation And Educational Eye And Face Protec-
tion, norme ANSI Z87.1, de l’American National Standards Institute,
1430 Broadway, New York, NY 10018.
NationalElectrical Code, NFPA Standard 70, de la National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.
Cutting and Welding Processes, norme NFPA 51B, de la National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.
1-5. Information sur les champs électromagnétiques
Données sur le soudage électrique et sur les effets, pour l’organisme,
des champs magnétiques basse fréquence
Afin de réduire les champs électromagnétiques dans l’environnement
de travail, respecter les consignes suivantes :
1
Garder les câbles ensembles en les torsadant ou en les
attachant avec du ruban adhésif.
Le courant de soudage, pendant son passage dans les câbles de sou-
dage, causera des champs électromagnétiques. Il y a eu et il y a encore
un certain souci à propos de tels champs. Cependant, après avoir ex-
aminé plus de 500 études qui ont été faites pendant une période de
recherche de 17 ans, un comité spécial ruban bleu du National Re-
search Council a conclu: “L’accumulation de preuves, suivant le
jugement du comité, n’a pas démontré que l’exposition aux champs
magnétiqueset champs électriques à haute fréquence représente un
risque à la santé humaine”. Toutefois, des études sont toujours en cours
et les preuves continuent à être examinées. En attendant que les con-
clusions finales de la recherche soient établies, il vous serait
souhaitablede réduire votre exposition aux champs électromagnéti-
ques pendant le soudage ou le coupage.
2
3
Mettre tous les câbles du côté opposé de l’opérateur.
Ne pas courber pas et ne pas entourer pas les câbles autour de
votre corps.
4
5
Garder le poste de soudage et les câbles le plus loin possible de
vous.
Relier la pince de masse le plus près possible de la zone de
soudure.
Consignes relatives aux stimulateurs cardiaques :
Les personnes qui portent un stimulateur cardiaque doivent avant tout
consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est
alors recommandé de respecter les consignes ci–dessus.
OM-808 Page 8
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 2 – SPECIFICATIONS
2-1. Resistance Grid
Specification
Description
Type Of Output
Coarse: 50 Ampere Steps; Fine: 5 Ampere Steps; Optional: 2-1/2 Ampere*
Height: 16 in (406 mm); Width: 16-1/2 in (419 mm); Length: 26 in (711 mm)
Overall Dimensions
300 Ampere
400 Ampere
250/250 Ampere
350/350 Ampere
Rated Welding Amperes 295 Amperes, 100% Duty 395 Amperes, 100% Duty 245 A, 490 A If Paralleled, 345 A, 690 A If Paralleled,
Output
Cycle
Cycle
100% Duty Cycle
100% Duty Cycle
Net Weight
With Case: 65 lb (20 kg);
W/O Case: 50 lb (23 kg)
With Case: 72 lb (33 kg);
W/O Case: 57 lb (26 kg)
With Case: 76 lb (34 kg);
W/O Case: 61 lb (28 kg)
With Case: 84 lb (38 kg);
W/O Case: 69 lb (31 kg)
2-2. Grid Rack
Specification
Description
4-Grid Rack
6-Grid Rack
Overall Dimensions
Net Weight
Height: 50-1/2 in (1334 mm);
Width: 39-1/4 in (997 mm);
Length: 35-3/4 in (908 mm)
Height: 50-1/2 in (1334 mm);
Width: 56 in (1422 mm);
Length: 35-3/4 in (908 mm)
204 lb (93 kg)
266 lb (121 kg)
OM-808 Page 9
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 3 – INSTALLATION
3-1. Typical Multiple Operator System Component Relationships
WARNING
ELECTRIC SHOCK can kill; TWO TIMES NORMAL OPEN-CIRCUIT VOLTS exists between
electrode holders of opposite polarity.
• Do not touch live electrical parts.
• Do not touch electrode holders of opposite polarity at the same time.
• Separate electrode holders of opposite polarity to prevent contact.
• Consult ANSI Z49.1 for common grounding safe practices.
1
2
3
4
5
6
7
Common Work Connection
Welding Power Source
Line Disconnect Device
Distribution Panel
MOG-4 Pak Grid Rack
Grid
This view illustrates how system
components are related.
MOG-6 Grid Rack
4
5
3
4
7
2
6
6
(+)
( )
DCEP
DCEN
1
S-0808-A
OM-808 Page 10
Download from Www.Somanuals.com. All Manuals Search And Download.
3-2. Selecting A Location And Moving Resistance Grid Or Multi-Grid Rack
Y
Turn Off welding power
source BEFORE moving grid
or rack.
Locate grid(s) near welding power
source.
ResistanceGrid
Have two persons of adequate physical
strength lift individual grids at handles.
1
18 in (460 mm) Open Space
On Front Side
Location should allow operation of
controls.
2
1
2
Handles
Use handles to lift unit.
Multi-Grid Rack
3
Minimum 20 in (508 mm)
Open Space On Front And
Rear Sides
Location should allow access to
rear panel and removal of grids.
Front
4
Lifting Eyes
Use four sets of lifting eyes to move
rack.
3
Rear
4
Front
4
Ref. ST-124 643-A / Ref. ST-151 556 / ST-161 154-A
OM-808 Page 11
Download from Www.Somanuals.com. All Manuals Search And Download.
3-3. Weld Input/Output Cables For Resistance Grid (Dual Model Shown)
Y
Turn Off welding power
source, and disconnect in-
put power before making any
weld output connections.
1
2
3
Weld Input Cable
Work Cable
Weld Output Cable
If necessary, use Section 3-7 to
select proper cable size.
Use shortest cables possible.
Do not use damaged cables.
4
Terminal Lug
9
Use lugs of proper amperage ca-
pacity and hole size for connecting
to common work, electrode hold-
er(s), and weld output terminals (if
applicable).
8
5
Common Work Connection
Connect work cable to common
work according to codes.
4
1
6
7
Insulated Electrode Holder
GTAW Torch
Install according to manufacturer’s
instructions.
2
8
8
Female Camlok Connector
Install onto weld input cable as
shown in Section 3-5.
10
5
9
Weld Input Receptacle
Connect cable to weld input recep-
tacle on rear panel of grid.
4
10 Male Camlok Connector
Install onto weld output cable as
shown in Section 3-6.
11 Electrode Receptacle
11
3
Connect electrode holder cable to
Electrode receptacle.
6
7
Or
Tools Needed:
S-0793
OM-808 Page 12
Download from Www.Somanuals.com. All Manuals Search And Download.
3-4. Weld Input/Output Cables For Multi-Grid Rack
1
2
3
Weld Input Cable
Work Cable
Y
Turn Off welding power source, and disconnect input
power before making any weld output connections.
Weld Output Cable
If necessary, use Section 3-7 to
select proper cable size.
Use shortest cables possible.
Do not use damaged cables.
4
Terminal Lug
Use lugs of proper amperage ca-
pacity and hole size for connecting
to common work, electrode hold-
er(s), and weld output terminals (if
applicable).
5
Common Work Connection
Connect work cable to common
work according to codes.
6
Input Terminal
For models with polarity reversing,
connect positive and negative
cables to matching input terminal.
6
For models without polarity revers-
ing, only one input terminal is pro-
vided. Connect electrode cable to
input terminal.
7
8
Insulated Electrode Holder
GTAW Torch
4
Install according to manufacturer’s
instructions.
9
Male Camlok Connector
Install onto weld output cable as
shown in Section 3-6.
10 Electrode Receptacle
Connect electrode holder cable to
Electrode receptacle.
4
1
2
5
9
4
10
3
Tools Needed:
7
8
Or
S-0799-A
OM-808 Page 13
Download from Www.Somanuals.com. All Manuals Search And Download.
3-5. Female Camlok Connector Assembly
1
Weld Input Cable
Strip insulation as shown.
1
2
2
3
Copper Strip (Two Included)
Connector Body
4
Wrap strip around bare weld cable
(use two on small diameter cable),
and insert into connector body.
3
4
Setscrew
Tighten setscrew against copper
strip.
1 in
(26 mm)
5
6
Handle
Pin
6
Slide handle over connector body
so holes align; secure by tapping
pin into place.
5
Tools Needed:
7/32 in
sb6.6* – ST-159 028
3-6. Male Camlok Connector Assembly
1
Weld Output Cable
Strip insulation as shown.
2
3
Copper Strip
Connector Body
1
2
Wrap strip around bare weld cable
(use two on small diameter cable),
and insert into connector body.
4
4
Setscrew
3
Tighten setscrew against copper
strip.
5
6
Handle
Pin
1 in
(26 mm)
Slide handle over connector body
so holes align; secure by tapping
pin into place.
6
5
Tools Needed:
7/32 in
sb6.4* 11/92 – ST-155 015
OM-808 Page 14
Download from Www.Somanuals.com. All Manuals Search And Download.
3-7. Weld Cable Size*
Total Cable (Copper) Length In Weld Circuit Not Exceeding
150 ft
(45 m)
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
(105 m)
400 ft
(120 m)
100 ft (30 m) Or Less
10 To 60% 60 Thru 100%
Welding
Amperes
10 Thru 100% Duty Cycle
Duty Cycle
Duty Cycle
100
150
200
250
300
350
400
500
600
700
800
4
4
3
4
2
3
2
1
1/0
1/0
3
1
1/0
2/0
3/0
3/0
3
2
1
1/0
2/0
3/0
4/0
4/0
2
1
1/0
2/0
3/0
3/0
4/0
2-2/0
2-3/0
2-3/0
2/0
3/0
4/0
2-2/0
2-3/0
2-3/0
2-4/0
3-3/0
3-4/0
3-4/0
4-4/0
2-2/0
2-3/0
2-4/0
2-4/0
3-3/0
3-4/0
4-4/0
4-4/0
1
1/0
2/0
2/0
3/0
4/0
2-2/0
2-2/0
3/0
4/0
2-2/0
2-3/0
2-3/0
2-4/0
3-3/0
3-4/0
3-4/0
1/0
1/0
2/0
3/0
4/0
4/0
4/0
2-2/0
2-2/0
2-3/0
2-4/0
3-3/0
3-4/0
4/0
2-2/0
2-3/0
2-4/0
2-4/0
*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
S-0007-D
3-8. Optional Remote Receptacle Information And Connections
1
Remote Receptacle
Single models have one Remote
receptacle RC3. Dual models have
two Remote receptacles RC3 and
RC4.
2
3
Keyway
Remote Grid Amperage
Control
4
5
Plug PLG1
Threaded Collar
To connect to this receptacle, align
keyway, insert plug, and tighten
threaded collar.
4
3
5
REMOTE
2
A
1
H
E
G
F
K
B
C
M
D
sb7.1 8/92* – Ref. S-0166-A / ST-080 370-A
OM-808 Page 15
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 4 – OPERATION
WARNING
ELECTRIC SHOCK can kill.
• Keep all panels and covers securely in place.
• Do not touch electrode holders of opposite polarity at the same time.
• Separate electrode holders of opposite polarity to prevent contact.
• See ANSI Z49.1 and OSHA TITLE 29, CHAPTER XVII, PART 1910, Subpart Q.
4-1. Controls (Dual Model Shown)
1
2
Coarse Amperage Control
Paralleling Switch
1
2
1
Included on dual models only.
3
4
Optional Polarity Switch
2-1/2 Ampere Switch
This switch is included on units with
Polarity switch. Switch is optional
for all other models.
5
Fine Amperage Control
3
4
4
5
5
Ref. ST-161 155
4-2. Safety Equipment
1
2
3
Wear the following while welding:
1
2
Dry, Insulating Gloves
Safety Glasses With Side
Shields
3
Welding Helmet With Correct
Shade Of Filter (See ANSI
Z49.1)
sb3.1 1/94
OM-808 Page 16
Download from Www.Somanuals.com. All Manuals Search And Download.
4-3. Work Clamp
1
Work Clamp
1
Connect work clamp to a clean,
paint-freelocation on workpiece, as
close to weld area as possible.
Tools Needed:
Use wire brush or sandpaper to
clean metal at weld joint area. Use
chipping hammer to remove slag
after welding.
sb4.1 2/93
4-4. Optional Polarity Switch
WARNING
ELECTRIC SHOCK can kill; TWO TIMES
NORMAL OPEN-CIRCUIT VOLTS exists
between electrode holders of opposite
polarity.
ARCING can damage switch.
• Do not change Polarity switch position while welding
or under load.
Arcing inside switch can damage contacts, causing
switch to fail.
• Do not touch live electrical parts.
• Do not touch electrode holders of opposite polarity
at the same time.
• Separate electrode holders of opposite polarity to
prevent contact.
• See ANSI Z49.1 and OSHA TITLE 29, CHAPTER
XVII, PART 1910, Subpart Q.
warn5.1* 2/93
1
Polarity Switch
Use switch to select polarity of weld
output.
For Direct Current Electrode Nega-
tive (DCEN), use Straight (Str)
position.
For Direct Current Electrode Posi-
tive (DCEP), use Reverse (Rev)
position.
1
Ref. ST-122 903-D
OM-808 Page 17
Download from Www.Somanuals.com. All Manuals Search And Download.
4-5. Amperage Controls
CAUTION
ARCING can damage switch.
• Do not change position of any Amperage control or switch while welding or under load.
Arcing inside switch can damage contacts, causing switch to fail.
1
Coarse Amperage Control
Use control to select coarse weld
amperageoutput.
To set amperage using only the
Fine Amperage control, place
Coarse Amperage control in Off
position.
2
2-1/2 Ampere Switch
(Optional)
Use switch to add 2-1/2 amperes to
weld output.
To add 2-1/2 amperes to weld
output, place switch in Off position.
For remote amperage adjustment,
place switch in Off position.
3
Fine Amperage Control
Use control to add amperage, in 5
ampere steps, to weld output.
For remote amperage adjustment,
place control in Off position.
2
In Example:
Total Amperage Output = 122.5 A
(100 A + 2.5 A)
3
OM-808 Page 18
Download from Www.Somanuals.com. All Manuals Search And Download.
4-6. Optional Remote Grid Amperage Control
Remote amperage control only
works when Fine Amperage control
and optional 2-1/2 Ampere switch
are in the Off position (see Section
4-5).
1
1
Remote Grid Amperage
Control
See Section 3-8 for installation.
Fine Amperage Control
2
Use control to add amperage, in 5
ampere steps, to weld output.
2
For front panel amperage adjust-
ment, place control in Off position.
3
2-1/2 Ampere Switch
3
Use switch to add 2-1/2 amperes to
weld output.
To add 2-1/2 amperes to weld
output, place switch in On position.
For front panel amperage adjust-
ment, place control in Off position.
ST-080 370-A / Ref. ST-122 903-D
4-7. Paralleling Switch (Dual Models Only)
CAUTION
ARCING can damage switch.
• Do not change Paralleling switch position while welding or under load.
Arcing inside switch can damage contacts, causing switch to fail.
warn5.1* 2/93
1
ParallelingSwitch
Use switch to select weld output at
one or both Electrode terminals.
For weld output at both Electrode
terminals, place switch in Single
position.
For total weld output at the left
Electrode terminal, place switch in
Parallelposition. Output at the right
terminal is 0 (zero).
When switch is in Parallel position,
all front panel amperage controls
(left and right) adjust weld output
(see Section 4-5).
1
Ref. ST-122 903-D
OM-808 Page 19
Download from Www.Somanuals.com. All Manuals Search And Download.
4-8. Sequence Of Shielded Metal Arc Welding (SMAW)
Install &
Connect
Equipment
Select
Electrode
Put On
Personal Safety
Equipment
Insert
Electrode
Into Holder
Turn On
Welding Power
Source
Set Controls
Begin Welding
ssb7.1 9/92
4-9. Sequence Of Gas Tungsten Arc Welding (GTAW)
Install &
Connect
Equipment
If Applicable,
Install High_
Frequency Unit
Select
Tungsten
Insert
Tungsten
Into Torch
Put On
Personal Safety
Equipment
Set Controls
Turn On
Shielding Gas
If Applicable,
Turn On High-
Frequency Unit
Turn On
Welding Power
Source
Begin Welding
ssb8.1* 12/92
SECTION 5 – MAINTENANCE & TROUBLESHOOTING
5-1. Routine Maintenance
Turn Off all power before maintaining.
3 Months
6 Months
Tape Or
Blow Out
Replace
Cracked
Cables
OR
Or
Vacuum
Inside
During Heavy Service,
Clean Monthly
Replace
Unreadable
Labels
Clean
And
Tighten Weld
Connections
Ref. ST-124 643-A
OM-808 Page 20
Download from Www.Somanuals.com. All Manuals Search And Download.
5-2. Overload Protection
Fuse link F1, or fuse links F1 and F2
for dual models, protect the grid
from overload damage. If weld
output stops, check link(s) as
follows:
Grid Rear Panel
Turn Off welding power source and
disconnect input power.
1
Fuse Link (See Parts List For
Rating)
Check and replace fuse link(s), if
necessary.
Close rear access door.
1
Multi-Grid Rack
Ref. ST-124 643-A / Ref. ST-161 156-A
5-3. Troubleshooting
Trouble
Remedy
No weld output.
Check and replace open fuse link(s), if necessary (see Section 5-2).
Check electrical input and output connections (see Section 3-3).
Select correct size weld cables according to Section 3-7.
Erratic or improper weld output.
Clean and tighten weld cable connections (see Section 3-3).
For dual models, be sure paralleling switch is in proper position (see Section 4-7).
If using remote control, be sure Fine Amperage control and 2-1/2 Ampere switch on grid are in the Off
position (see Section 4-5).
OM-808 Page 21
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 6 – ELECTRICAL DIAGRAMS
SA-044 882-A
Figure 6-1. Circuit Diagram For 300 Ampere Model
SA-096 447-A
Figure 6-2. Circuit Diagram For 300 Ampere Model With Polarity Reversing
OM-808 Page 22
Download from Www.Somanuals.com. All Manuals Search And Download.
SA-044 884-A
Figure 6-3. Circuit Diagram For 400 Ampere Model
SA-096 445-A
Figure 6-4. Circuit Diagram For 400 Ampere Model With Polarity Reversing
OM-808 Page 23
Download from Www.Somanuals.com. All Manuals Search And Download.
SA-044 886-A
Figure 6-5. Circuit Diagram For 250/250 Ampere Model
SB-124 202
Figure 6-6. Circuit Diagram For 250/250 Ampere Model With Polarity Reversing
OM-808 Page 24
Download from Www.Somanuals.com. All Manuals Search And Download.
SA-087 783-A
Figure 6-7. Circuit Diagram For 350/350 Ampere Model
SA-095 027-A
Figure 6-8. Circuit Diagram For Remote Grid Controls
OM-808 Page 25
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION 7 – PARTS LIST
. Hardware is common and
not available unless listed.
ST-124 640-A
Figure 7-1. Main Assembly
OM-808 Page 26
Download from Www.Somanuals.com. All Manuals Search And Download.
Quantity
Model
300
AC
400
250/250 350/350
Item
No.
Dia.
Mkgs.
Part
No.
Description
A
A
AC A/B AC/BC A AC
Figure 7-1. Main Assembly
. . 1 . . . . . . . . . . . . 049 472 . . . RAIL, grid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2 . 2 . 2 . 2 . 2 . 2 . 2
. . 2 . . . . . . . . . . . . 049 470 . . . BRACKET, side frame . . . . . . . . . . . . . . . . . . . . . . . 2 . 2 . 2 . 2 . 2 . 2 . 2 . 2
. . 3 . . . . . . . . . . +049 590 . . . EXTENSION, handle . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1
. . 4 . . . . . . . . . . +010 651 . . . PIN, spring 5/32 x 1 . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1
. . 5 . . . . . . . . . . +049 497 . . . PANEL, mtg plrt switch . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1
. . 6 . . . . . . . . . . +049 633 . . . TUBING, cop .540 OD x .123 wall x 1/2 . . . . . . . . . . . . . . . . . . . . . . . 2 . 2
. . 7 . . . . . . . . . . . +049 611 . . . TUBING, cop .540 OD x .123 wall x 11/16 . . . . . . . . . . . . . . . . . . . . . 1 . 1
. . 8 . . . . . . . . . . +049 610 . . . BUS BAR, switch pos 1/4 x 1 x 3-1/4 . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1
. . 9 . . . . . . . . . . +049 602 . . . BUS BAR, input pos 1/4 x 1 x 7-5/8
(400 APRC, 250/250 BPR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . 9 . . . . . . . . . . . . 089 721 . . . BUS BAR, input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . 9 . . . . . . . . . . +049 429 . . . BUS BAR, plrt 1/8 x 1 x 6-7/16 . . . . . . . . . . . . . . . . 1 . 1
. . 9 . . . . . . . . . . . . 049 426 . . . BUS BAR, input single 1/4 x 3-3/8 x 7-1/4 . . . . . . . . . . 1
. . 9 . . . . . . . . . . . . 049 503 . . . BUS BAR, input 1/4 x 3-7/16 x 4-13/16 . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . . . . . . . . . . . . . . +059 861 . . . BUS BAR, interconnect 1/8 x 1 x 3-13/16 . . . . . . . 1 . 1
. . . . . . . . . . . . . . . . . 089 724 . . . BUS BAR, interconnect 3/16 x 1 x 7-1/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1
. . . . . . . . . . . . . . . +049 433 . . . BUS BAR, input pos 1/4 x 1 x 9-3/4 . . . . . . . . . . . . . . . . 1
. . 10 . . F1 . . . . *059 945 . . . FUSE, link 250A 250V . . . . . . . . . . . . . . . . . . . . . . . 2 . 2
. . 10 . F1,2 . . *+059 945 . . . FUSE, link 250A 250V . . . . . . . . . . . . . . . . . . . . . . . 4 . 4
. . 10 . . F1 . . . . *027 267 . . . FUSE, link 300A 250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2
. . 10 . F1,2 . . *+027 267 . . . FUSE, link 300A 250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . 4
. . 10 . . F1 . . . . *059 943 . . . FUSE, link 350A 250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2
. . 10 . F1,2 . . *+059 943 . . . FUSE, link 350A 250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . 4
. . 10 . . F1 . . . . *086 042 . . . FUSE, link 400A 250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . 3
. . 11 . . . . . . . . . +049 608 . . . BUS BAR, common 1/4 x 1 x 11-7/8 . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1
. . 12 . . . . . . . . . . . 059 805 . . . TUBING, cop 540 OD x .123 wall x 5/16 . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1 . . . . . .
. . 13 . . . . . . . . . . . 010 907 . . . NUT, locking 1 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1
. . 13 . . . . . . . . . +010 907 . . . NUT, locking 1 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2 . . . . 2
. . 14 . . . . . . . . . . . 010 854 . . . NUT, speed No. 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1
. . 15 . . . . . . . . . . . 056 271 . . . RECEPTACLE, twlk male . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1
. . 15 . . . . . . . . . +056 271 . . . RECEPTACLE, twlk male . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2 . . . . 2
. . 16 . . . . . . . . . . . 039 633 . . . CONNECTOR, quick connect twlk female . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1
. . 16 . . . . . . . . . +039 633 . . . CONNECTOR, quick connect twlk female . . . . . . . . . . 2 . . . . 2 . . . . 2 . . . . . .
. . 17 . . . . . . . . . . . 010 853 . . . FASTENER, scr slotted hd No. 2 . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1
. . 18 . . . . . . . . . . . 010 855 . . . RETAINER, scr No. 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1
. . 19 . . . . . . . . . . . 049 500 . . . PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1
. . . . . . . . . . . . . . . . . 080 381 . . . COVER, camlock opening . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1
. . 20 . . . . . . . . . +049 428 . . . BUS BAR, interconnect 1/8 x 1 x 1-1/4 . . . . . . . . . 1 . 1
. . 20 . . . . . . . . . +049 607 . . . BUS BAR, switch neg 1/4 x 1 x 1-1/2 . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1
. . 21 . . . . . . . . . . . 059 857 . . . BUS BAR, plrt single 1/8 x 1 x 7-5/8 . . . . . . . . . . . . . . . 1
. . 21 . . . . . . . . . +049 431 . . . BUS BAR, input neg 1/8 x 1 x 3-7/8 . . . . . . . . . . . . . . . . 1 . .
. . 21 . . . . . . . . . . . 059 852 . . . BUS BAR, plrt single 1/4 x 1 x 7-5/8 . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . . 1
. . 21 . . . . . . . . . +049 604 . . . BUS BAR, input neg 1/4 x 1 x 3-1/4 . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . 22 . . . . . . . . . . . 134 327 . . . LABEL, warning general precautionary . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1
. . 23 . . . . . . . . ++049 504 . . . WRAPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1
. . 24 . . S3 . . . +049 434 . . . SWITCH, plrt reverse . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1
. . 24 . . S3 . . . +049 612 . . . SWITCH, plrt reverse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1
. . 24 . . S3 . . . +049 612 . . . SWITCH, plrt reverse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1
. . . . . . . . . . . . . . . +049 633 . . . PIPE, cop 1/4 x 1/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1
. . . . . . . . . . . . . . . . +049 611 . . . PIPE, cop 1/4 x 11/16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . 2 . 3 . 1
. . 25 . . . . . . . . . . . 049 496 . . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1
. . 26 . . . . . . . . . . . 049 469 . . . HANDLE, carrying . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2 . 2 . 2 . 2 . 2 . 2 . 2
. . 27 . . . . . . . . . . . 107 734 . . . ANGLE, mtg bracket (also APR & BPR) . . . . . . . . 1 . . . . . 1 . . . . . 1 . . . . . 1
. . 28 . . . . . . . . . +059 866 . . . HANDLE, switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1
. . 29 . . . . . . . . . +010 647 . . . PIN, spring 5/32 x 1-1/4 . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1
. . 30 . . . . . . . . . . . . Fig 7-2 . . . PANEL, front w/components . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1 . 1 . 1
OM-808 Page 27
Download from Www.Somanuals.com. All Manuals Search And Download.
Quantity
Model
300
AC
400
250/250 350/350
Item
No.
Dia.
Mkgs.
Part
No.
Description
A
A
AC A/B AC/BC A AC
Figure 7-1. Main Assembly (Continued)
. . 31 . . . . . . . . . . . 049 563 . . . RESISTOR ASSEMBLY, current (Fig 3) . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1 . 1 . 1
. . 31 . . . . . . . . . . . 049 615 . . . RESISTOR ASSEMBLY, current (Fig 3) . . . . . . . . . . . . . . . . 1 . 1
. . 31 . . . . . . . . . . . 049 562 . . . RESISTOR ASSEMBLY, current (Fig 3) . . . . . . . . . . . . . . . . . . . . . . . 1 . 1
. . 31 . . . . . . . . . . . 089 729 . . . RESISTOR ASSEMBLY, current (Fig 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1
. . . . . . . . . . . . . . . . . 600 322 . . . CABLE, weld No. 2/0 (also 300APR)
(order by ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3ft
. . . . . . . . . . . . . . . . . 600 323 . . . CABLE, weld No. 3 (also 250/250BPR & 400APR)
(order by ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3ft . . . 3ft . . . 3ft
+PR models only.
*Recommended Spare Parts.
++When ordering a component originally displaying a precautionary label, the label should also be ordered.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
. Hardware is common and
not available unless listed.
7
8
6
9
10
11
15
12
13
14
5
4
1
2
3
5
4
16
7
8
17
18
19
1
21
20
24 23
22
ST-124 641-A
Figure 7-2. Panel, Front w/Components
OM-808 Page 28
Download from Www.Somanuals.com. All Manuals Search And Download.
Quantity
Model
300
AC
400
250/250 350/350
Item
No.
Dia.
Mkgs.
Part
No.
Description
A
A
AC A/B AC/BC A AC
Figure 7-2. Panel, Front w/Components
(Fig 7-1 Item 30)
. . 1 . . . S4 . . . ♦011 609 . . . SWITCH, tgl SPDT 15A 125V . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1
. . 1 . . S8,9 . . ♦011 609 . . . SWITCH, tgl SPDT 15A 125V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2
. . 2 . . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE,
(order by model and serial number) . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1 . 1 . 1
. . 3 . . . . . . . . . . . . 049 486 . . . PANEL, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1 . 1 . 1
. . 4 . . . . . . . . . . . . 059 804 . . . TUBING, cop 1/4 IPS x 7/16 . . . . . . . . . . . . . . . . . . 2 . 2 . 4 . 4 . 3 . 3 . 6 . 6
. . 5 . . . . . . . . . . . . 059 805 . . . TUBING, cop 1/4 IPS x 5/16 . . . . . . . . . . . . . . . . . . 1 . 1 . . . . . . . . 3 . 3 . 3 . 3
. . 5 . . . . . . . . . . . . 059 803 . . . TUBING, cop 1/4 IPS x 3/16 . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1
. . 6 . . . S2 . . . . . 049 560 . . . SWITCH, current LH high . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1
. . 6 . . . S2 . . . . . 089 727 . . . SWITCH, current LH high . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1
. . 7 . . . . . . . . . . . . 059 875 . . . TUBING, 3/8 OD x 0.256 ID x 7/16 . . . . . . . . . . . . 1 . 1
. . 7 . . . . . . . . . . . . 059 876 . . . TUBING, 3/8 OD x 0.256 ID x 11/16 . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2
. . 8 . . . . . . . . . . . . 059 874 . . . TUBING, 3/8 OD x 0.256 ID x 1-3/8 . . . . . . . . . . . 1 . 1
. . 8 . . . . . . . . . . . . 010 199 . . . TUBING, 0.275 ID x 0.048 wall x 1 . . . . . . . . . . . . . . . . . . . . 1 . 1 . . . . . . . . 2 . 2
. . 8 . . . . . . . . . . . . 059 873 . . . TUBING, 3/8 OD x 0.256 ID x 1-5/8 . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2
. . 9 . . . . . . . . . . . . 049 477 . . . BUS BAR, output 1/8 x 1 x 7-1/8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1
. . 10 . . . . . . . . . . . 049 567 . . . BUS BAR, output 1/8 x 1 x 5-9/16 . . . . . . . . . . . . . 1 . 1 . 2 . 2 . 1 . 1 . 1 . 1
. . 11 . . S5 . . . . . 049 571 . . . SWITCH, paralleling (if applicable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1
. . 12 . . . . . . . . . . . 059 872 . . . TUBING, 3/8 OD x 0.256 ID x 2-1/2 . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2 . 2 . 2
. . 13 . . . . . . . . . . . 049 568 . . . BUS BAR, output 1/8 x 1 x 5-9/16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1
. . 14 . . . . . . . . . . . 049 569 . . . BUS BAR, interconnect 1/8 x 1 x 2-1/4 . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1
. . 15 . . . . . . . . . . . 049 485 . . . BAFFLE, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1
. . 15 . . . . . . . . . . . 089 732 . . . BAFFLE, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1
. . 16 . . S1 . . . . . 059 734 . . . SWITCH, current 10posn . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1
. . 16 . S1,3 . . . . 059 734 . . . SWITCH, current 10posn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2 . 2 . 2
. . 17 . . S2 . . . . . 049 435 . . . SWITCH, current high . . . . . . . . . . . . . . . . . . . . . . . 1 . 1
. . 17 . . S2 . . . . . 049 613 . . . SWITCH, current high . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1
. . 17 . . S4 . . . . . 049 561 . . . SWITCH, current RH high . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1
. . 17 . . S4 . . . . . 089 728 . . . SWITCH, current RH high . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1
. . 18 . RC3 . . ♦039 718 . . . RECEPTACLE, 10skt MS-3102A-18-1S . . . . . . . . 1 . 1 . 1 . 1
. . 18 . RC3,4 . ♦039 718 . . . RECEPTACLE, 10skt MS-3102A-18-1S . . . . . . . . . . . . . . . . . . . . . . . 2 . 2 . 2 . 2
. . 19 . . . . . . . . . . . 010 907 . . . NUT, locking 1 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 2 . 2 . 2 . 2
. . 20 . . . . . . . . . . . 006 790 . . . KNOB, switch fine . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 2 . 2 . 2 . 2
. . 21 . RC1 . . . . 039 628 . . . RECEPTACLE, twlk insul . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1
. . 21 . RC1,2 . . . 039 628 . . . RECEPTACLE, twlk insul . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2 . 2 . 2
. . 22 . . . . . . . . . . . 039 630 . . . PLUG, male twlk insul . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 2 . 2 . 2 . 2
. . 23 . . . . . . . . . . . 010 647 . . . PIN, spring 5/32 x 1-1/4 . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 3 . 3 . 3 . 3
. . 24 . . . . . . . . . . . 059 773 . . . HANDLE, switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 3 . 3 . 3 . 3
♦Parts for optional equipment.
+PR models only.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-808 Page 29
Download from Www.Somanuals.com. All Manuals Search And Download.
Quantity
Model
300
400 250/250 350/350
Item
No.
Dia.
Mkgs.
Part
No.
Description
049 563 049 615 049 562
089 729
Figure 7-3. Resistor Assembly, Current
(Fig 7-1 Item 31)
. . 1 . . . . . . . . . . . . . . . . 049 479 . . BUS BAR, connecting resistors . . . . . . . . . . . 1 . . . . 5 . . . . 6 . . . . . . 2
. . . . . . . . . . . . . . . . . . . . . 059 841 . . BUS BAR, connecting resistors . . . . . . . . . . . . . . . . . . 1
. . 2 . . . . . . R1 . . . . . . 059 797 . . RESISTOR, 5A . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . 2 . . . . . R4,14 . . . . . 059 797 . . RESISTOR, 5A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . . . 2
. . 3 . . . . . R5-7 . . . . . 059 800 . . RESISTOR, 25A . . . . . . . . . . . . . . . . . . . . . . . 10
. . 3 . . . . . R5-8 . . . . . 059 800 . . RESISTOR, 25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
. . 3 . . . R1-3,8-10 . . . 059 800 . . RESISTOR, 25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
. . 3 . . . R1-3,8-10 . . . 059 800 . . RESISTOR, 25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
. . . . . . . . . . . . . . . . . . . . . 059 726 . . INSULATOR, end . . . . . . . . . . . . . . . . . . . . . . 28 . . . 36 . . . 48 . . . . . 64
. . . . . . . . . . . . . . . . . . . . . 059 728 . . INSULATOR, support . . . . . . . . . . . . . . . . . . . 22 . . . 30 . . . 36 . . . . . 52
. . . . . . . . . . . . . . . . . . . . . 059 727 . . INSULATOR, support 5/8 bore . . . . . . . . . . . . 6 . . . . 6 . . . 12 . . . . . 12
. . . . . . . . . . . . . . . . . . . . . 059 724 . . RING, retaining ext .886 x 0.021 . . . . . . . . . 34 . . . 42 . . . 60 . . . . . 76
. . . . . . . . . . . . . . . . . . . . . 059 725 . . RING, retaining ext 1.379 x 0.025 . . . . . . . . 22 . . . 30 . . . 36 . . . . . 52
. . 4 . . . . . . . . . . . . . . . . 049 476 . . BUS BAR, connecting resistors . . . . . . . . . . . 1 . . . . 1 . . . . 2
. . 5 . . . . . . . . . . . . . . . . 049 475 . . BUS BAR, connecting resistors . . . . . . . . . . . 1 . . . . 1 . . . . 2
. . 6 . . . . . . . . . . . . . . . . 049 481 . . BUS BAR, connecting resistors . . . . . . . . . . . 4 . . . . 4 . . . . 4 . . . . . . 2
. . 7 . . . . . . . . . . . . . . . . 049 478 . . BUS BAR, connecting resistors . . . . . . . . . . . 1 . . . . 2 . . . . 2 . . . . . . 4
. . . . . . . . . . . . . . . . . . . . . 089 725 . . BUS BAR, connecting resistors (6 hole) . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
. . . . . . . . . . . . . . . . . . . . . 089 723 . . BUS BAR, connecting resistors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . 089 726 . . BUS BAR, connecting resistors (6 hole) . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
7
. Hardware is common and
6
not available unless listed.
1
5
4
7
8
1
6
4
3
2
9
5
1
14
16
15
1
6
1
10
11
14
12
13
12
SC-124 642
10
Figure 7-3. Resistor Assembly, Current
OM-808 Page 30
Download from Www.Somanuals.com. All Manuals Search And Download.
Quantity
Model
300
400 250/250 350/350
Item
No.
Dia.
Mkgs.
Part
No.
Description
049 563 049 615 049 562
089 729
Figure 7-3. Resistor Assembly, Current
(Fig 1 Item 31)
. . 8 . . . . . . . . . . . . . ♦♦049 570 . . BUS BAR, interconnecting resistors . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . .
. . 8 . . . . . . . . . . . . . . . . 049 570 . . BUS BAR, interconnecting resistors . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . 2
. . 9 . . . . . . . . . . . . . . . . 049 480 . . BUS BAR, connecting resistors . . . . . . . . . . . 1 . . . . 1 . . . . 2
. . 10 . . . . . . . . . . . . . ♦057 430 . . WASHER, centering No. 18 . . . . . . . . . . . . . . 2 . . . . 2 . . . . 4
. . 11 . . . . . . . . . . . . . ♦081 016 . . BRACKET, mtg resistor . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 2
. . 12 . . . . . . . . . . . . . ♦059 933 . . WASHER, mica 3/4 ID x 1-1/2 OD . . . . . . . . 2 . . . . 2 . . . . 4
. . 13 . . . . . R8 . . . . ♦059 932 . . RESISTOR, WW fxd 175W 20 ohm . . . . . . . 1
. . 13 . . . . . R9 . . . . ♦059 932 . . RESISTOR, WW fxd 175W 20 ohm . . . . . . . . . . . . . . 1
. . 13 . . . R15,16 . . ♦059 932 . . RESISTOR, WW fxd 175W 20 ohm . . . . . . . . . . . . . . . . . . . . . 2
. . 14 . . . . R2,3 . . . . . 059 798 . . RESISTOR, 10A . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2
. . 14 . R5,6,12,13 . . 059 798 . . RESISTOR, 10A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . . . . . . 4
. . 15 . . . . . . . . . . . . . ♦604 714 . . BOLT, carriage 1/4-20 x 9 . . . . . . . . . . . . . . . . 2 . . . . 2 . . . . 2
. . 16 . . . . . R4 . . . . . . 059 799 . . RESISTOR, 20A . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1
. . 16 . . . . R7,11 . . . . . 059 799 . . RESISTOR, 20A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . . . 2
♦♦Not part of this assembly.
♦These parts are optional on all units not equipped with factory installed polarity switch.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-808 Page 31
Download from Www.Somanuals.com. All Manuals Search And Download.
. Hardware is common and
not available unless listed.
1
2
3
4
5
6
7
8
9
12
11
10
SD-080 254-E
Figure 7-4. MOG-Pak 6 APR
OM-808 Page 32
Download from Www.Somanuals.com. All Manuals Search And Download.
Quantity
PAK 4A
PAK 2A
PAK 6A
Item
No.
Part
No.
Single
Dual
Single
Dual
Single
Dual
Description
Polarity Polarity Polarity Polarity Polarity Polarity
Figure 7-4. MOG-Pak 2, 4, & 6
1
1
1
2
3
3
3
4
4
4
5
6
6
6
6
6
6
049 758 ANGLE, guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 690 ANGLE, guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 541 ANGLE, guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
123 154 LABEL, general precautionary . . . . . . . . . . . . . . . . . . . . . . . .
+085 342 ROOF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+085 341 ROOF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+085 340 ROOF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 771 FRAME, grid rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 706 FRAME, grid rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 545 FRAME, grid rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 540 PANEL, baffle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 770 TERMINAL ASSEMBLY, plrt single (consisting of) . . . . . . .
049 769 TERMINAL ASSEMBLY, plrt dual (consisting of) . . . . . . . .
049 708 TERMINAL ASSEMBLY, plrt single (consisting of) . . . . . . .
049 707 TERMINAL ASSEMBLY, plrt dual (consisting of) . . . . . . . .
049 535 TERMINAL ASSEMBLY, plrt single (consisting of) . . . . . . .
049 534 TERMINAL ASSEMBLY, plrt dual (consisting of) . . . . . . . .
049 768 · TERMINAL BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 709 · TERMINAL BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 533 · TERMINAL BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 757 · STRIP, mtg term . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
080 183 · STRIP, mtg term . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
080 186 · STRIP, mtg term LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
080 187 · STRIP, mtg term RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
602 216 · WASHER, lock split 1/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
601 879 · NUT, brs hex full 1/2-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 767 PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 703 PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 536 PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
027 529 PIN, cotter 1/4 x 3-1/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 766 PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 700 PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 539 PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
059 872 TUBING, stl 3/8 OD x 0.256 ID x 2-1/2 . . . . . . . . . . . . . . . .
010 199 TUBING, stl 0.275 ID x 0.048 wall x 1 . . . . . . . . . . . . . . . . .
080 139 SCREW, flat hd 1/4-20 x 6 . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
2
1
1
1
1
2
2
2
2
1
2
2
1
1
1
1
2
1
1
7
7
7
8
9
9
9
10
11
12
1
2
1
1
2
1
1
3
1
3
2
1
2
1
1
4
8
4
1
4
8
4
4
8
4
4
8
4
4
8
4
4
8
4
Optional Equipment
6
6
6
6
6
6
085 349 TERMINAL ASSEMBLY, plrt single (consisting of) . . . . . . .
085 346 TERMINAL ASSEMBLY, plrt dual (consisting of) . . . . . . . .
085 351 TERMINAL ASSEMBLY, plrt single (consisting of) . . . . . . .
085 347 TERMINAL ASSEMBLY, plrt dual (consisting of) . . . . . . . .
085 350 TERMINAL ASSEMBLY, plrt single (consisting of) . . . . . . .
085 348 TERMINAL ASSEMBLY, plrt dual (consisting of) . . . . . . . .
049 768 · TERMINAL BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 709 · TERMINAL BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
049 533 · TERMINAL BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
085 331 · STRIP, mtg term . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
085 332 · STRIP, mtg term . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
085 333 · STRIP, mtg term . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
085 334 · STRIP, mtg term . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
1
1
1
1
1
1
1
1
2
1
1
1
2
1
1
1
1
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-808 Page 33
Download from Www.Somanuals.com. All Manuals Search And Download.
Quantity
Model
Item
No.
Part
No.
Description
2.5 Amp 5 Amp
Figure 7-5. Remote Control
. 1 . . . . . . . . 080 194 . . . WRAPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1
. . . . . . . . . . . . 138 033 . . . CONNECTOR, circ clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1
. 2 . . . . . . . . 600 798 . . . CABLE, No. 16 10/c (order by ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100ft . . . 100ft
. 3 . . . . . . . . 039 736 . . . CLAMP, cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1
. 4 . . . . . . . . 039 716 . . . CONNECTOR, circ 10 pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1
. 5 . . . . . . . . 080 198 . . . CASE SECTION, base/front/rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1
. . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE (order by model number) . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1
. 6 . . . . . . . . 006 790 . . . KNOB, switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1
. . . . . . . . . . . . 059 734 . . . SWITCH, current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1
. 7 . . . . . . . . 053 359 . . . SWITCH, tgl SPST 20A 125V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1
2
1
3
4
7
6
. Hardware is common and
not available unless listed.
5
SA-080 370-A
Figure 7-5. Remote Control
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-808 Page 34
Download from Www.Somanuals.com. All Manuals Search And Download.
Effective January 1, 2000
(Equipment with a serial number preface of “LA” or newer)
This limited warranty supersedes all previous Miller warranties and is exclusive with no other
guarantees or warranties expressed or implied.
Warranty Questions?
LIMITED WARRANTY – Subject to the terms and conditions
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants
to its original retail purchaser that new Miller equipment sold
after the effective date of this limited warranty is free of defects
in material and workmanship at the time it is shipped by Miller.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS.
*
APT, ZIPCUT & PLAZCUT Model Plasma Cutting
Torches
Call
1-800-4-A-MILLER
for your local
Miller distributor.
*
*
*
*
*
Remote Controls
Accessory Kits
Replacement Parts (No labor)
Spoolmate 185 & Spoolmate 250
Canvas Covers
Within the warranty periods listed below, Miller will repair or
replace any warranted parts or components that fail due to
such defects in material or workmanship. Miller must be
notified in writing within thirty (30) days of such defect or
failure, at which time Miller will provide instructions on the
warranty claim procedures to be followed.
Your distributor also gives
you ...
Miller’s True Blue Limited Warranty shall not apply to:
1. Consumable components; such as contact tips,
cutting nozzles, contactors, brushes, slip rings,
relays or parts that fail due to normal wear.
Service
You always get the fast,
reliable response you
need. Most replacement
parts can be in your
hands in 24 hours.
Miller shall honor warranty claims on warranted equipment
listed below in the event of such a failure within the warranty
time periods. All warranty time periods start on the date that
the equipment was delivered to the original retail purchaser, or
one year after the equipment is sent to a North American
distributor or eighteen months after the equipment is sent to an
International distributor.
2. Items furnished by Miller, but manufactured by others,
such as engines or trade accessories. These items are
covered by the manufacturer’s warranty, if any.
Support
3. Equipment that has been modified by any party other
than Miller, or equipment that has been improperly
installed, improperly operated or misused based upon
industry standards, or equipment which has not had
reasonable and necessary maintenance, or equipment
which has been used for operation outside of the
specifications for the equipment.
Need fast answers to the
tough welding questions?
Contact your distributor.
The expertise of the
distributor and Miller is
there to help you, every
step of the way.
1. 5 Years Parts – 3 Years Labor
*
*
Original main power rectifiers
Inverters (input and output rectifiers only)
MILLER PRODUCTS ARE INTENDED FOR PURCHASE
AND USE BY COMMERCIAL/INDUSTRIAL USERS AND
PERSONS TRAINED AND EXPERIENCED IN THE USE
AND MAINTENANCE OF WELDING EQUIPMENT.
2. 3 Years — Parts and Labor
*
*
*
*
*
*
Transformer/Rectifier Power Sources
Plasma Arc Cutting Power Sources
Semi-Automatic and Automatic Wire Feeders
Inverter Power Supplies
In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at Miller’s option: (1) repair; or (2)
replacement; or, where authorized in writing by Miller in
appropriate cases, (3) the reasonable cost of repair or
replacement at an authorized Miller service station; or (4)
payment of or credit for the purchase price (less reasonable
depreciation based upon actual use) upon return of the goods
at customer’s risk and expense. Miller’s option of repair or
replacement will be F.O.B., Factory at Appleton, Wisconsin, or
F.O.B. at a Miller authorized service facility as determined by
Miller. Therefore no compensation or reimbursement for
transportation costs of any kind will be allowed.
Intellitig
Engine Driven Welding Generators
(NOTE: Engines are warranted separately by
the engine manufacturer.)
3. 1 Year — Parts and Labor
*
*
DS-2 Wire Feeder
Motor Driven Guns (w/exception of Spoolmate
185 & Spoolmate 250)
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR
DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
PROFIT), WHETHER BASED ON CONTRACT, TORT OR
ANY OTHER LEGAL THEORY.
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Process Controllers
Positioners and Controllers
Automatic Motion Devices
RFCS Foot Controls
Induction Heating Power Sources
Water Coolant Systems
HF Units
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN
AND ANY IMPLIED WARRANTY, GUARANTY OR
REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
OTHER LEGAL THEORY WHICH, BUT FOR THIS
Grids
Maxstar 140
PROVISION,
MIGHT
ARISE
BY
IMPLICATION,
Spot Welders
OPERATION OF LAW, CUSTOM OF TRADE OR COURSE
OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE, WITH RESPECT TO ANY AND ALL
EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND
DISCLAIMED BY MILLER.
Load Banks
Miller Cyclomatic Equipment
Running Gear/Trailers
Plasma Cutting Torches (except APT & SAF
Models)
Some states in the U.S.A. do not allow limitations of how long
an implied warranty lasts, or the exclusion of incidental,
indirect, special or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty
provides specific legal rights, and other rights may be
available, but may vary from state to state.
*
Field Options
(NOTE: Field options are covered under True
Blue for the remaining warranty period of the
product they are installed in, or for a minimum of
one year — whichever is greater.)
In Canada, legislation in some provinces provides for certain
additional warranties or remedies other than as stated herein,
and to the extent that they may not be waived, the limitations
and exclusions set out above may not apply. This Limited
Warranty provides specific legal rights, and other rights may
be available, but may vary from province to province.
4. 6 Months — Batteries
5. 90 Days — Parts
*
*
MIG Guns/TIG Torches
Induction Heating Coils and Blankets
miller_warr 7/00
Download from Www.Somanuals.com. All Manuals Search And Download.
Owner’s Record
Please complete and retain with your personal records.
Model Name
Purchase Date
Distributor
Address
Serial/Style Number
(Date which equipment was delivered to original customer.)
City
State
Zip
For Service
to locate a DISTRIBUTOR or SERVICE AGENCY near you.
Always provide Model Name and Serial/Style Number.
Contact your Distributor for:
Welding Supplies and Consumables
Options and Accessories
Personal Safety Equipment
Service and Repair
Miller Electric Mfg. Co.
An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA
Replacement Parts
Training (Schools, Videos, Books)
International Headquarters–USA
USA Phone: 920-735-4505 Auto-Attended
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125
Technical Manuals (Servicing Information
and Parts)
Circuit Diagrams
European Headquarters –
United Kingdom
Phone: 44 (0) 1204-593493
FAX: 44 (0) 1204-598066
Welding Process Handbooks
Contact the Delivering Carrier for:
File a claim for loss or damage during
shipment.
For assistance in filing or settling claims,
contact your distributor and/or equipment
manufacturer’s Transportation Department.
PRINTED IN USA
2000 Miller Electric Mfg. Co. 6/00
Download from Www.Somanuals.com. All Manuals Search And Download.
|