Miller Electric Welder MOG 250 User Manual

OM-808  
081 904F  
January 1997  
Processes  
TIG (GTAW) Welding  
Stick (SMAW) Welding  
Description  
Multiple Operator Resistance Grids  
(MOG), Racks, And Remote Controls  
MOG-250/250, MOG-300, MOG-350/350,  
MOG-400, MOG-Pak, And RGC Controls  
Visit our website at  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
The following terms are  
used interchangeably  
throughout this manual:  
TIG = GTAW  
SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-3. Additional Symbols for Installation, Operation, and Maintenance . . . . . . . . . . . . . . . . . . . . . .  
1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SECTION 1 – CONSIGNES DE SECURITE – LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . .  
1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-2. Dangers relatifs au soudage à larc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1
1
1
3
3
4
5
5
5
Stick = SMAW  
1-3. Dangers supplémentaires en relation avec linstallation, le fonctionnement  
et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
7
8
8
9
9
9
1-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SECTION 2 – SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-1. Resistance Grid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-2. Grid Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SECTION 3 – INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
3-1. Typical Multiple Operator System Component Relationships . . . . . . . . . . . . . . . . . . . . . . . . .  
3-2. Selecting A Location And Moving Resistance Grid Or Multi-Grid Rack . . . . . . . . . . . . . . . . .  
3-3. Weld Input/Output Cables For Resistance Grid (Dual Model Shown) . . . . . . . . . . . . . . . . . . .  
3-4. Weld Input/Output Cables For Multi-Grid Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-5. Female Camlok Connector Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-6. Male Camlok Connector Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-7. Weld Cable Size* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-8. Optional Remote Receptacle Information And Connections . . . . . . . . . . . . . . . . . . . . . . . . . .  
10  
11  
12  
13  
14  
14  
15  
15  
SECTION 4 – OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
4-1. Controls (Dual Model Shown) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-2. Safety Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-3. Work Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-4. Optional Polarity Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-5. Amperage Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-6. Optional Remote Grid Amperage Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-7. Paralleling Switch (Dual Models Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-8. Sequence Of Shielded Metal Arc Welding (SMAW) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
4-9. Sequence Of Gas Tungsten Arc Welding (GTAW) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
16  
16  
17  
17  
18  
19  
19  
20  
20  
SECTION 5 – MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
5-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
5-2. Fuse Link Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
5-3. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
20  
21  
21  
SECTION 6 – ELECTRICAL DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22  
SECTION 7 – PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26  
OPTIONS AND ACCESSORIES  
WARRANTY  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1 SAFETY PRECAUTIONS - READ BEFORE USING  
som _nd_5/97  
1-1. Symbol Usage  
Means Warning! Watch Out! There are possible hazards  
with this procedure! The possible hazards are shown in  
the adjoining symbols.  
This group of symbols means Warning! Watch Out! possible  
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.  
Consult symbols and related instructions below for necessary actions  
to avoid the hazards.  
Y
Marks a special safety message.  
. Means “Note”; not safety related.  
1-2. Arc Welding Hazards  
Y
The symbols shown below are used throughout this manual to  
call attention to and identify possible hazards. When you see  
the symbol, watch out, and follow the related instructions to  
avoid the hazard. The safety information given below is only  
a summary of the more complete safety information found in  
the Safety Standards listed in Section 1-4. Read and follow all  
Safety Standards.  
D
D
D
If earth grounding of the workpiece is required, ground it directly  
with a separate cable do not use work clamp or work cable.  
Do not touch electrode if you are in contact with the work, ground,  
or another electrode from a different machine.  
Use only well-maintained equipment. Repair or replace damaged  
parts at once. Maintain unit according to manual.  
D
D
D
Wear a safety harness if working above floor level.  
Keep all panels and covers securely in place.  
Y
Y
Only qualified persons should install, operate, maintain, and  
repair this unit.  
During operation, keep everybody, especially children, away.  
Clamp work cable with good metal-to-metal contact to workpiece  
or worktable as near the weld as practical.  
D
D
Insulate work clamp when not connected to workpiece to prevent  
contact with any metal object.  
ELECTRIC SHOCK can kill.  
Do not connect more than one electrode or work cable to any  
single weld output terminal.  
Touching live electrical parts can cause fatal shocks  
or severe burns. The electrode and work circuit is  
electrically live whenever the output is on. The input  
power circuit and machine internal circuits are also  
SIGNIFICANT DC VOLTAGE exists after removal of  
input power on inverters.  
live when power is on. In semiautomatic or automatic wire welding, the  
wire, wire reel, drive roll housing, and all metal parts touching the  
welding wire are electrically live. Incorrectly installed or improperly  
groundedequipment is a hazard.  
D
Turn Off inverter, disconnect input power, and discharge input  
capacitors according to instructions in Maintenance Section  
before touching any parts.  
D
D
D
Do not touch live electrical parts.  
Wear dry, hole-free insulating gloves and body protection.  
FUMES AND GASES can be hazardous.  
Insulate yourself from work and ground using dry insulating mats  
or covers big enough to prevent any physical contact with the work  
or ground.  
Welding produces fumes and gases. Breathing  
these fumes and gases can be hazardous to your  
health.  
D
Do not use AC output in damp areas, if movement is confined, or if  
there is a danger of falling.  
D
D
Keep your head out of the fumes. Do not breathe the fumes.  
D
D
Use AC output ONLY if required for the welding process.  
If inside, ventilate the area and/or use exhaust at the arc to remove  
welding fumes and gases.  
If AC output is required, use remote output control if present on  
unit.  
D
D
If ventilation is poor, use an approved air-supplied respirator.  
D
Disconnect input power or stop engine before installing or  
servicing this equipment. Lockout/tagout input power according to  
OSHA 29 CFR 1910.147 (see Safety Standards).  
Read the Material Safety Data Sheets (MSDSs) and the  
manufacturers instructions for metals, consumables, coatings,  
cleaners, and degreasers.  
D
D
Properly install and ground this equipment according to its  
Owners Manual and national, state, and local codes.  
D
Work in a confined space only if it is well ventilated, or while  
wearing an air-supplied respirator. Always have a trained watch-  
person nearby. Welding fumes and gases can displace air and  
lower the oxygen level causing injury or death. Be sure the breath-  
ing air is safe.  
Always verify the supply ground check and be sure that input  
power cord ground wire is properly connected to ground terminal in  
disconnect box or that cord plug is connected to a properly  
groundedreceptacle outlet.  
D
D
Do not weld in locations near degreasing, cleaning, or spraying op-  
erations. The heat and rays of the arc can react with vapors to form  
highly toxic and irritating gases.  
D
D
When making input connections, attach proper grounding conduc-  
tor first double-check connections.  
Frequently inspect input power cord for damage or bare wiring –  
replace cord immediately if damaged bare wiring can kill.  
Do not weld on coated metals, such as galvanized, lead, or  
cadmiumplated steel, unless the coating is removed from the weld  
area, the area is well ventilated, and if necessary, while wearing an  
air-suppliedrespirator. The coatings and any metals containing  
these elements can give off toxic fumes if welded.  
D
D
D
Turn off all equipment when not in use.  
Do not use worn, damaged, undersized, or poorly spliced cables.  
Do not drape cables over your body.  
OM-808 Page 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ARC RAYS can burn eyes and skin.  
BUILDUP OF GAS can injure or kill.  
D
D
Shut off shielding gas supply when not in use.  
Arc rays from the welding process produce intense  
visible and invisible (ultraviolet and infrared) rays  
that can burn eyes and skin. Sparks fly off from the  
weld.  
Always ventilate confined spaces or use  
approved air-supplied respirator.  
D
Wear a welding helmet fitted with a proper shade of filter to protect  
your face and eyes when welding or watching (see ANSI Z49.1  
and Z87.1 listed in Safety Standards).  
HOT PARTS can cause severe burns.  
D
D
D
Wear approved safety glasses with side shields under your  
helmet.  
D
D
Do not touch hot parts bare handed.  
Use protective screens or barriers to protect others from flash and  
glare; warn others not to watch the arc.  
Allow cooling period before working on gun or  
torch.  
Wear protective clothing made from durable, flame-resistant mate-  
rial (leather and wool) and foot protection.  
MAGNETIC FIELDS can affect pacemakers.  
WELDING can cause fire or explosion.  
D
D
Pacemaker wearers keep away.  
Wearers should consult their doctor before  
going near arc welding, gouging, or spot  
welding operations.  
Welding on closed containers, such as tanks,  
drums, or pipes, can cause them to blow up. Sparks  
can fly off from the welding arc. The flying sparks, hot  
workpiece, and hot equipment can cause fires and  
burns. Accidental contact of electrode to metal objects can cause  
sparks, explosion, overheating, or fire. Check and be sure the area is  
safe before doing any welding.  
NOISE can damage hearing.  
D
D
D
Protect yourself and others from flying sparks and hot metal.  
Do not weld where flying sparks can strike flammable material.  
Noise from some processes or equipment can  
damagehearing.  
Remove all flammables within 35 ft (10.7 m) of the welding arc. If  
this is not possible, tightly cover them with approved covers.  
D
Wear approved ear protection if noise level is  
high.  
D
Be alert that welding sparks and hot materials from welding can  
easily go through small cracks and openings to adjacent areas.  
D
D
Watch for fire, and keep a fire extinguisher nearby.  
CYLINDERS can explode if damaged.  
Be aware that welding on a ceiling, floor, bulkhead, or partition can  
cause fire on the hidden side.  
Shielding gas cylinders contain gas under high  
pressure. If damaged, a cylinder can explode. Since  
gas cylinders are normally part of the welding  
process, be sure to treat them carefully.  
D
D
Do not weld on closed containers such as tanks, drums, or pipes,  
unless they are properly prepared according to AWS F4.1 (see  
Safety Standards).  
Connect work cable to the work as close to the welding area as  
practical to prevent welding current from traveling long, possibly  
unknown paths and causing electric shock and fire hazards.  
D
D
Protect compressed gas cylinders from excessive heat, mechani-  
cal shocks, slag, open flames, sparks, and arcs.  
Install cylinders in an upright position by securing to a stationary  
support or cylinder rack to prevent falling or tipping.  
D
D
Do not use welder to thaw frozen pipes.  
Remove stick electrode from holder or cut off welding wire at  
contact tip when not in use.  
D
D
D
D
D
Keep cylinders away from any welding or other electrical circuits.  
Never drape a welding torch over a gas cylinder.  
D
D
Wear oil-free protective garments such as leather gloves, heavy  
shirt, cuffless trousers, high shoes, and a cap.  
Never allow a welding electrode to touch any cylinder.  
Never weld on a pressurized cylinder explosion will result.  
Remove any combustibles, such as a butane lighter or matches,  
from your person before doing any welding.  
Use only correct shielding gas cylinders, regulators, hoses, and fit-  
tings designed for the specific application; maintain them and  
associated parts in good condition.  
FLYING METAL can injure eyes.  
D
D
Turn face away from valve outlet when opening cylinder valve.  
D
Welding, chipping, wire brushing, and grinding  
cause sparks and flying metal. As welds cool,  
they can throw off slag.  
Keep protective cap in place over valve except when cylinder is in  
use or connected for use.  
D
Read and follow instructions on compressed gas cylinders,  
associated equipment, and CGA publication P-1 listed in Safety  
Standards.  
D
Wear approved safety glasses with side  
shields even under your welding helmet.  
OM-808 Page 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-3. Additional Symbols For Installation, Operation, And Maintenance  
FIRE OR EXPLOSION hazard.  
MOVING PARTS can cause injury.  
D
Do not install or place unit on, over, or near  
combustiblesurfaces.  
D
D
Keep away from moving parts such as fans.  
Keep all doors, panels, covers, and guards  
closed and securely in place.  
D
Do not install unit near flammables.  
D
Do not overload building wiring be sure power supply system is  
properly sized, rated, and protected to handle this unit.  
FALLING UNIT can cause injury.  
H.F. RADIATION can cause interference.  
D
D
D
Use lifting eye to lift unit only, NOT running  
gear, gas cylinders, or any other accessories.  
D
High-frequency (H.F.) can interfere with radio  
navigation, safety services, computers, and  
communicationsequipment.  
Use equipment of adequate capacity to lift and  
support unit.  
D
Have only qualified persons familiar with  
electronic equipment perform this installation.  
If using lift forks to move unit, be sure forks are  
long enough to extend beyond opposite side of  
unit.  
D
D
The user is responsible for having a qualified electrician prompt-  
ly correct any interference problem resulting from the installa-  
tion.  
If notified by the FCC about interference, stop using the  
equipmentat once.  
OVERUSE can cause OVERHEATING  
D
D
Allow cooling period; follow rated duty cycle.  
D
D
Have the installation regularly checked and maintained.  
Reduce current or reduce duty cycle before  
starting to weld again.  
Keep high-frequency source doors and panels tightly shut, keep  
spark gaps at correct setting, and use grounding and shielding to  
minimize the possibility of interference.  
D
Do not block or filter airflow to unit.  
STATIC (ESD) can damage PC boards.  
D
D
Put on grounded wrist strap BEFORE handling  
boards or parts.  
ARC WELDING can cause interference.  
Use proper static-proof bags and boxes to  
store, move, or ship PC boards.  
D
Electromagnetic energy can interfere with  
sensitive electronic equipment such as  
computers and computer-driven equipment  
such as robots.  
MOVING PARTS can cause injury.  
D
Be sure all equipment in the welding area is  
electromagneticallycompatible.  
D
D
Keep away from moving parts.  
Keep away from pinch points such as drive  
rolls.  
D
D
D
D
To reduce possible interference, keep weld cables as short as  
possible, close together, and down low, such as on the floor.  
Locate welding operation 100 meters from any sensitive elec-  
tronic equipment.  
WELDING WIRE can cause injury.  
Be sure this welding machine is installed and grounded  
according to this manual.  
D
D
Do not press gun trigger until instructed to do  
so.  
If interference still occurs, the user must take extra measures  
such as moving the welding machine, using shielded cables,  
using line filters, or shielding the work area.  
Do not point gun toward any part of the body,  
other people, or any metal when threading  
welding wire.  
1-4. Principal Safety Standards  
Safety in Welding and Cutting, ANSI Standard Z49.1, from American  
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126  
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,  
from Compressed Gas Association, 1235 Jefferson Davis Highway,  
Suite 501, Arlington, VA 22202.  
Safety and Health Standards, OSHA 29 CFR 1910, from Superinten-  
dent of Documents, U.S. Government Printing Office, Washington, D.C.  
20402.  
Code for Safety in Welding and Cutting, CSA Standard W117.2, from  
Canadian Standards Association, Standards Sales, 178 Rexdale  
Boulevard, Rexdale, Ontario, Canada M9W 1R3.  
Safe Practices For Occupation And Educational Eye And Face  
Protection, ANSI Standard Z87.1, from American National Standards  
Institute, 1430 Broadway, New York, NY 10018.  
Recommended Safe Practices for the Preparation for Weldingand Cut-  
ting of Containers That Have Held Hazardous Substances, American  
Welding Society Standard AWS F4.1, from American Welding Society,  
550 N.W. LeJeune Rd, Miami, FL 33126  
NationalElectrical Code, NFPA Standard 70, from National Fire Protec-  
tion Association, Batterymarch Park, Quincy, MA 02269.  
Cutting And Welding Processes, NFPA Standard 51B, from National  
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.  
OM-808 Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-5. EMF Information  
Considerations About Welding And The Effects Of Low Frequency  
Electric And Magnetic Fields  
1. Keep cables close together by twisting or taping them.  
2. Arrange cables to one side and away from the operator.  
3. Do not coil or drape cables around your body.  
Welding current, as it flows through welding cables, will cause electro-  
magnetic fields. There has been and still is some concern about such  
fields. However, after examining more than 500 studies spanning 17  
years of research, a special blue ribbon committee of the National  
Research Council concluded that: The body of evidence, in the  
committees judgment, has not demonstrated that exposure to power-  
frequency electric and magnetic fields is a human-health hazard.”  
However, studies are still going forth and evidence continues to be  
examined.Until the final conclusions of the research are reached, you  
may wish to minimize your exposure to electromagnetic fields when  
welding or cutting.  
4. Keep welding power source and cables as far away from opera-  
tor as practical.  
5. Connect work clamp to workpiece as close to the weld as possi-  
ble.  
About Pacemakers:  
To reduce magnetic fields in the workplace, use the following  
procedures:  
Pacemaker wearers consult your doctor first. If cleared by your doctor,  
then following the above procedures is recommended.  
OM-808 Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1 CONSIGNES DE SECURITE LIRE AVANT  
UTILISATION  
som _nd_fre 5/97  
1-1. Signification des symboles  
SignifieMise en garde ! Soyez vigilant ! Cette procédure  
présente des risques de danger ! Ceux-ci sont identifiés  
par des symboles adjacents aux directives.  
Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des  
risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN  
MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles  
et aux directives ci-dessous afin de connaître les mesures à prendre pour  
éviter tout danger.  
Y
Identifie un message de sécurité particulier.  
. Signifie NOTA ; nest pas relatif à la sécurité.  
1-2. Dangers relatifs au soudage à larc  
Y
Les symboles présentés ci-après sont utilisés tout au long du  
présent manuel pour attirer votre attention et identifier les risques  
de danger. Lorsque vous voyez un symbole, soyez vigilant et  
suivez les directives mentionnées afin d’éviter tout danger. Les  
consignes de sécurité présentées ci-après ne font que résumer  
linformation contenue dans les normes de sécurité énumérées  
à la section 1-4. Veuillez lire et respecter toutes ces normes de  
sécurité.  
D
D
Ne pas toucher l’électrode quand on est en contact avec la pièce, la  
terre ou une électrode provenant dune autre machine.  
Nutiliser quun matériel en bon état. Réparer ou remplacer sur-le-  
champ les pièces endommagées. Entretenir lappareil conformément  
à ce manuel.  
D
D
D
Porter un harnais de sécurité quand on travaille en hauteur.  
Maintenir solidement en place tous les panneaux et capots.  
Y
Y
Linstallation, lutilisation, lentretien et les réparations ne doi-  
vent être confiés qu’à des personnes qualifiées.  
Fixer le câble de retour de façon à obtenir un bon contact métal-métal  
avec la pièce à souder ou la table de travail, le plus près possible de la  
soudure.  
Au cours de lutilisation, tenir toute personne à l’écart et plus par-  
ticulièrement les enfants.  
D
Isoler la pince de masse quand pas mis à la pièce pour éviter le contact  
avec tout objet métallique.  
UN CHOC ÉLECTRIQUE peut tuer.  
Un simple contact avec des pièces électriques peut  
provoquer une électrocution ou des blessures graves.  
L’électrode et le circuit de soudage sont sous tension  
dès que lappareil est sur ON. Le circuit dentrée et les  
circuits internes de lappareil sont également sous  
Il y a DU COURANT CONTINU IMPORTANT dans les  
convertisseurs après la suppression de lalimenta-  
tion électrique.  
D
Arrêter les convertisseurs, débrancher le courant électrique, et dé-  
charger les condensateurs dalimentation selon les instructions  
indiquées dans la partie entretien avant de toucher les pièces.  
tension à ce moment-là. En soudage semi-automatique ou automatique,  
le fil, le dévidoir, le logement des galets dentraînement et les pièces  
métalliques en contact avec le fil de soudage sont sous tension. Des  
matériels mal installés ou mal mis à la terre présentent un danger.  
D
D
Ne jamais toucher les pièces électriques sous tension.  
Porter des gants et des vêtements de protection secs ne comportant  
pas de trous.  
LES FUMÉES ET LES GAZ peuvent  
D
Sisoler de la pièce et de la terre au moyen de tapis ou dautres  
moyens isolants suffisamment grands pour empêcher le contact phy-  
sique éventuel avec la pièce ou la terre.  
Ne pas se servir de source électrique àcourant électrique dans les zones  
humides, dans les endroits confinés ou là où on risque de tomber.  
être dangereux.  
Le soudage génère des fumées et des gaz. Leur  
D
D
D
D
inhalation peut être dangereux pour votre santé.  
D
Eloigner votre tête des fumées. Ne pas respirer  
Se servir dune source électrique àcourant électrique UNIQUEMENT si le  
procédé de soudage le demande.  
les fumées.  
D
A lintérieur, ventiler la zone et/ou utiliser un échappement au niveau  
de larc pour l’évacuation des fumées et des gaz de soudage.  
Si la ventilation est insuffisante, utiliser un respirateur à alimenta-  
tion dair homologué.  
Lire les spécifications de sécurité des matériaux (MSDSs) et les  
instructions du fabricant concernant les métaux, les consomma-  
bles, les revêtements, les nettoyants et les dégraisseurs.  
Travailler dans un espace fermé seulement sil est bien ventilé ou en  
portant un respirateur à alimentation dair. Demander toujours à un  
surveillant dûment formé de se tenir à proximité. Des fumées et des  
gaz de soudage peuvent déplacer lair et abaisser le niveau doxy-  
gène provoquant des blessures ou des accidents mortels. Sassu-  
rer que lair de respiration ne présente aucun danger.  
Si lutilisation dune source électrique àcourant électrique savère néces-  
saire, se servir de la fonction de télécommande si lappareil en est équipé.  
D
D
Couper lalimentation ou arrêter le moteur avant de procéder à linstal-  
lation, à la réparation ou à lentretien de lappareil. Déverrouiller  
lalimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de  
sécurité).  
Installer et mettre à la terre correctement cet appareil conformément à  
son manuel dutilisation et aux codes nationaux, provinciaux et  
municipaux.  
Toujours vérifier la terre du cordon dalimentation Vérifier et sassu-  
rer que le fil de terre du cordon dalimentation est bien raccordé à la  
borne de terre du sectionneur ou que la fiche du cordon est raccordée  
à une prise correctement mise à la terre.  
D
D
D
D
D
Ne pas souder dans des endroits situés à proximité dopérations de  
dégraissage, de nettoyage ou de pulvérisation. La chaleur et les  
rayons de larc peuvent réagir en présence de vapeurs et former des  
gaz hautement toxiques et irritants.  
Ne pas souder des métaux munis dun revêtement, tels que lacier  
galvanisé, plaqué en plomb ou au cadmium à moins que le revête-  
ment nait été enlevé dans la zone de soudure, que lendroit soit bien  
ventilé, et si nécessaire, en portant un respirateur à alimentation  
dair. Les revêtements et tous les métaux renfermant ces éléments  
peuvent dégager des fumées toxiques en cas de soudage.  
D
D
En effectuant les raccordements dentrée fixer dabord le conducteur  
de mise à la terre approprié et contre-vérifier les connexions.  
Vérifier fréquemment le cordon dalimentation pour voir sil nest pas  
endommagé ou dénudé – remplacer le cordon immédiatement sil est  
endommagé – un câble dénudé peut provoquer une électrocution.  
Mettre lappareil hors tension quand on ne lutilise pas.  
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffi-  
sante ou mal épissés.  
D
D
D
D
Ne pas enrouler les câbles autour du corps.  
Si la pièce soudée doit être mise à la terre, le faire directement avec un  
câble distinct ne pas utiliser le connecteur de pièce ou le câble de  
retour.  
OM-808 Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LES RAYONS DE LARC peuvent pro-  
voquer des brûlures dans les yeux et  
sur la peau.  
LES ACCUMULATIONS DE GAZ ris-  
quent de provoquer des blessures ou  
même la mort.  
Le rayonnement de larc du procédé de soudage  
génère des rayons visibles et invisibles intenses  
(ultraviolets et infrarouges) susceptibles de provoquer  
des brûlures dans les yeux et sur la peau. Des étincelles sont projetées  
pendant le soudage.  
D
Fermer lalimentation du gaz protecteur en cas de  
non utilisation.  
D
Veiller toujours à bien aérer les espaces confinés ou se servir dun respi-  
rateur dadduction dair homologué.  
D
Porter un casque de soudage muni dun écran de filtre approprié pour  
protéger votre visage et vos yeux pendant le soudage ou pour regar-  
der (voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).  
DES PIÈCES CHAUDES peuvent pro-  
voquer des brûlures graves.  
D
D
Porter des protections approuvés pour les oreilles si le niveau sondre est  
trop élevé.  
Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair  
et de l’éblouissement; demander aux autres personnes de ne pas re-  
garder larc.  
Porter des vêtements de protection constitué dans une matière dura-  
ble, résistant au feu (cuir ou laine) et une protection des pieds.  
D
D
Ne pas toucher des parties chaudes à mains nues  
Prévoir une période de refroidissement avant  
dutiliser le pistolet ou la torche.  
D
LE SOUDAGE peut provoquer un  
incendie ou une explosion.  
Le soudage effectué sur des conteneurs fermés tels  
que des réservoirs, tambours ou des conduites peut  
provoquer leur éclatement. Des étincelles peuvent être  
projetées de larc de soudure. La projection d’étincel-  
LES CHAMPS MAGNÉTIQUES peuvent  
affecter les stimulateurs cardiaques.  
D
D
Porteurs de stimulateur cardiaque, restez à distance.  
Les porteurs dun stimulateur cardiaque doivent  
dabord consulter leur médecin avant de sapprocher  
des opérations de soudage à larc, de gougeage ou  
de soudage par points.  
les, des pièces chaudes et des équipements chauds peut provoquer des  
incendies et des brûlures. Le contact accidentel de l’électrode avec des  
objets métalliques peut provoquer des étincelles, une explosion, un  
surchauffement ou un incendie. Avant de commencer le soudage, vérifier  
et sassurer que lendroit ne présente pas de danger.  
D
D
D
Se protéger et dautres personnes de la projection d’étincelles et de  
LE BRUIT peut affecter louïe.  
métal chaud.  
Ne pas souder dans un endroit là où des étincelles peuvent tomber sur  
des substances inflammables.  
Le bruit des processus et des équipements peut affecter  
louïe.  
Déplacer toutes les substances inflammables à une distance de 10,7  
m de larc de soudage. En cas dimpossibilité les recouvrir soigneuse-  
ment avec des protections homologués.  
Des étincelles et des matériaux chauds du soudage peuvent facile-  
ment passer dans dautres zones en traversant de petites fissures et  
des ouvertures.  
D
Porter des protections approuvés pour les oreilles si  
le niveau sondre est trop élevé.  
D
D
D
D
Surveiller tout déclenchement dincendie et tenir un extincteur à proxi-  
Si des BOUTEILLES sont endomma-  
gées, elles pourront exploser.  
mité.  
Le soudage effectué sur un plafond, plancher, paroi ou séparation  
peut déclencher un incendie de lautre côté.  
Des bouteilles de gaz protecteur contiennent du gaz  
sous haute pression. Si une bouteille est endomma-  
gée, elle peut exploser. Du fait que les bouteilles de gaz  
font normalement partie du procédé de soudage, les  
Ne pas effectuer le soudage sur des conteneurs fermés tels que des  
réservoirs, tambours, ou conduites, à moins quils naient été prépa-  
rés correctement conformément à AWS F4.1 (voir les normes de  
sécurité).  
Brancher le câble sur la pièce le plus près possible de la zone de sou-  
dage pour éviter le transport du courant sur une longue distance par  
des chemins inconnus éventuels en provoquant des risques d’élec-  
trocution et dincendie.  
Ne pas utiliser le poste de soudage pour dégeler des conduites ge-  
lées.  
En cas de non utilisation, enlever la baguette d’électrode du porte-  
électrode ou couper le fil à la pointe de contact.  
Porter des vêtements de protection dépourvus dhuile tels que des  
gants en cuir, une chemise en matériau lourd, des pantalons sans re-  
vers, des chaussures hautes et un couvre chef.  
Avant de souder, retirer toute substance combustible de vos poches  
telles quun allumeur au butane ou des allumettes.  
manipuler avec précaution.  
D
D
D
D
Protéger les bouteilles de gaz comprimé dune chaleur excessive,  
des chocs mécaniques, du laitier, des flammes ouvertes, des étin-  
celles et des arcs.  
Placer les bouteilles debout en les fixant dans un support stationnai-  
re ou dans un porte-bouteilles pour les empêcher de tomber ou de  
se renverser.  
Tenir les bouteilles éloignées des circuits de soudage ou autres cir-  
cuits électriques.  
Ne jamais placer une torche de soudage sur une bouteille à gaz.  
Une électrode de soudage ne doit jamais entrer en contact avec une  
D
D
D
D
D
bouteille.  
D
D
D
Ne jamais souder une bouteille pressurisée risque dexplosion.  
Utiliser seulement des bouteilles de gaz protecteur, régulateurs,  
tuyaux et raccords convenables pour cette application spécifique;  
les maintenir ainsi que les éléments associés en bon état.  
DES PARTICULES VOLANTES  
peuvent blesser les yeux.  
D
D
D
Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la  
bouteille.  
Maintenir le chapeau de protection sur la soupape, sauf en cas duti-  
lisation ou de branchement de la bouteille.  
Lire et suivre les instructions concernant les bouteilles de gaz com-  
primé, les équipements associés et les publications P-1 CGA énu-  
mérées dans les normes de sécurité.  
D
Le soudage, l’écaillement, le passage de la pièce  
à la brosse en fil de fer, et le meulage génèrent  
des étincelles et des particules métalliques vo-  
lantes. Pendant la période de refroidissement des soudures, elles ris-  
quent de projeter du laitier.  
D
Porter des lunettes de sécurité avec écrans latéraux ou un écran facial.  
OM-808 Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-3. Dangers supplémentaires en relation avec linstallation, le fonctionnement  
et la maintenance  
Risque DINCENDIE OU  
DEXPLOSION.  
DES ORGANES MOBILES peuvent  
provoquer des blessures.  
D
Ne pas placer lappareil sur, au-dessus ou à proxi-  
mité de surfaces infllammables.  
D
D
Rester à l’écart des organes mobiles comme le  
ventilateur.  
Maintenir fermés et fixement en place les portes,  
panneaux, recouvrements et dispositifs de  
protection.  
D
D
Ne pas installer lappareil à proximité de produits inflammables  
Ne pas surcharger linstallation électrique sassurer que lalimen-  
tation est correctement dimensionné et protégé avant de mettre  
lappareil en service.  
LE RAYONNEMENT HAUTE FRÉ-  
QUENCE (H.F.) risque de provoquer  
des interférences.  
LA CHUTE DE LAPPAREIL peut  
blesser.  
D
Le rayonnement haute frequence peut provoquer  
des interférences avec les équipements de ra-  
dionavigationet de communication, les services  
de sécurité et les ordinateurs.  
D
D
Utiliser lanneau de levage uniquement pour sou-  
lever lappareil, NON PAS les chariot, les bouteil-  
les de gaz ou tout autre accessoire.  
D
Demander seulement à des personnes qualifiées familiarisées  
avec des équipements électroniques de faire fonctionner linstalla-  
tion.  
Lutilisateur est tenu de faire corriger rapidement par un électricien  
qualifié les interférences résultant de linstallation.  
Utiliser un engin dune capacité appropriée pour  
soulever lappareil.  
D
En utilisant des fourches de levage pour déplacer lunité, sassurer  
que les fourches sont suffisamment longues pour dépasser du côté  
opposé de lappareil.  
D
D
Si le FCC signale des interférences, arrêter immédiatement lappa-  
reil.  
LEMPLOI EXCESSIF peut  
SURCHAUFFER L’ÉQUIPEMENT.  
D
D
Effectuer régulièrement le contrôle et lentretien de linstallation.  
Maintenir soigneusement fermés les portes et les panneaux des  
sources de haute fréquence, maintenir les éclateurs à une distance  
correcte et utiliser une terre et et un blindage pour réduire les interfé-  
rences éventuelles.  
D
D
Prévoir une période de refroidissement, respec-  
ter le cycle opératoire nominal.  
Réduire le courant ou le cycle opératoire avant de  
recommancer le soudage.  
LE SOUDAGE À LARC risque de  
D
Ne pas obstruer les passages dair du poste.  
provoquer des interférences.  
LES CHARGES ÉLECTROSTATI-  
QUES peuvent endommager les cir-  
cuits imprimés.  
D
L’énergie électromagnétique risque de provoquer  
des interférences pour l’équipement électronique  
sensible tel que les ordinateurs et l’équipement  
commandé par ordinateur tel que les robots.  
D
D
Veiller à ce que tout l’équipement de la zone de soudage soit com-  
D
D
Établir la connexion avec la barrette de terre  
patible électromagnétiquement.  
avant de manipuler des cartes ou des pièces.  
Pour réduire la possibilité dinterférence, maintenir les câbles de  
soudage aussi courts que possible, les grouper, et les poser aussi  
bas que possible (ex. par terre).  
Veiller à souder à une distance de 100 mètres de tout équipement  
électronique sensible.  
Veiller à ce que ce poste de soudage soit posé et mis à la terre  
conformément à ce mode demploi.  
En cas dinterférences après avoir pris les mesures précédentes, il  
incombe à lutilisateur de prendre des mesures supplémentaires tel-  
les que le déplacement du poste, lutilisation de câbles blindés, luti-  
lisation de filtres de ligne ou la pose de protecteurs dans la zone de  
travail.  
Utiliser des pochettes et des boîtes antistatiques  
pour stocker, déplacer ou expédier des cartes de  
circuits imprimes.  
D
D
D
DES ORGANES MOBILES peuvent  
provoquer des blessures.  
D
D
Ne pas sapprocher des organes mobiles.  
Ne pas sapprocher des points de coincement  
tels que des rouleaux de commande.  
LES CHAMPS MAGNÉTIQUES peuvent  
affecter les stimulateurs cardiaques.  
LES FILS DE SOUDAGE peuvent pro-  
voquer des blessures.  
D
D
Porteurs de stimulateur cardiaque, restez à dis-  
D
D
Ne pas appuyer sur la gachette avant den avoir  
reçu linstruction.  
tance.  
Les porteurs dun stimulateur cardiaque doivent  
dabord consulter leur médecin avant de sappro-  
cher des opérations de soudage à larc, de gou-  
geage ou de soudage par points.  
Ne pas diriger le pistolet vers soi, dautres person-  
nes ou toute pièce mécanique en engageant le fil  
de soudage.  
OM-808 Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-4. Principales normes de sécurité  
Safety in Welding and Cutting, norme ANSI Z49.1, de lAmerican Wel-  
ding Society, 550 N.W. Lejeune Rd, Miami FL 33126  
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,  
de la Compressed Gas Association, 1235 Jefferson Davis Highway,  
Suite 501, Arlington, VA 22202.  
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent  
of Documents, U.S. Government Printing Office, Washington, D.C.  
20402.  
Règles de sécurité en soudage, coupage et procédés connexes, norme  
CSA W117.2, de lAssociation canadienne de normalisation, vente de  
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.  
RecommendedSafe Practice for the Preparation for Welding and Cut-  
ting of Containers That Have Held Hazardous Substances, norme AWS  
F4.1, de lAmerican Welding Society, 550 N.W. Lejeune Rd, Miami FL  
33126  
Safe Practices For Occupation And Educational Eye And Face Protec-  
tion, norme ANSI Z87.1, de lAmerican National Standards Institute,  
1430 Broadway, New York, NY 10018.  
NationalElectrical Code, NFPA Standard 70, de la National Fire Protec-  
tion Association, Batterymarch Park, Quincy, MA 02269.  
Cutting and Welding Processes, norme NFPA 51B, de la National Fire  
Protection Association, Batterymarch Park, Quincy, MA 02269.  
1-5. Information sur les champs électromagnétiques  
Données sur le soudage électrique et sur les effets, pour lorganisme,  
des champs magnétiques basse fréquence  
Afin de réduire les champs électromagnétiques dans lenvironnement  
de travail, respecter les consignes suivantes :  
1
Garder les câbles ensembles en les torsadant ou en les  
attachant avec du ruban adhésif.  
Le courant de soudage, pendant son passage dans les câbles de sou-  
dage, causera des champs électromagnétiques. Il y a eu et il y a encore  
un certain souci à propos de tels champs. Cependant, après avoir ex-  
aminé plus de 500 études qui ont été faites pendant une période de  
recherche de 17 ans, un comité spécial ruban bleu du National Re-  
search Council a conclu: Laccumulation de preuves, suivant le  
jugement du comité, na pas démontré que lexposition aux champs  
magnétiqueset champs électriques à haute fréquence représente un  
risque à la santé humaine. Toutefois, des études sont toujours en cours  
et les preuves continuent à être examinées. En attendant que les con-  
clusions finales de la recherche soient établies, il vous serait  
souhaitablede réduire votre exposition aux champs électromagnéti-  
ques pendant le soudage ou le coupage.  
2
3
Mettre tous les câbles du côté opposé de lopérateur.  
Ne pas courber pas et ne pas entourer pas les câbles autour de  
votre corps.  
4
5
Garder le poste de soudage et les câbles le plus loin possible de  
vous.  
Relier la pince de masse le plus près possible de la zone de  
soudure.  
Consignes relatives aux stimulateurs cardiaques :  
Les personnes qui portent un stimulateur cardiaque doivent avant tout  
consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est  
alors recommandé de respecter les consignes cidessus.  
OM-808 Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 2 SPECIFICATIONS  
2-1. Resistance Grid  
Specification  
Description  
Type Of Output  
Coarse: 50 Ampere Steps; Fine: 5 Ampere Steps; Optional: 2-1/2 Ampere*  
Height: 16 in (406 mm); Width: 16-1/2 in (419 mm); Length: 26 in (711 mm)  
Overall Dimensions  
300 Ampere  
400 Ampere  
250/250 Ampere  
350/350 Ampere  
Rated Welding Amperes 295 Amperes, 100% Duty 395 Amperes, 100% Duty 245 A, 490 A If Paralleled, 345 A, 690 A If Paralleled,  
Output  
Cycle  
Cycle  
100% Duty Cycle  
100% Duty Cycle  
Net Weight  
With Case: 65 lb (20 kg);  
W/O Case: 50 lb (23 kg)  
With Case: 72 lb (33 kg);  
W/O Case: 57 lb (26 kg)  
With Case: 76 lb (34 kg);  
W/O Case: 61 lb (28 kg)  
With Case: 84 lb (38 kg);  
W/O Case: 69 lb (31 kg)  
2-2. Grid Rack  
Specification  
Description  
4-Grid Rack  
6-Grid Rack  
Overall Dimensions  
Net Weight  
Height: 50-1/2 in (1334 mm);  
Width: 39-1/4 in (997 mm);  
Length: 35-3/4 in (908 mm)  
Height: 50-1/2 in (1334 mm);  
Width: 56 in (1422 mm);  
Length: 35-3/4 in (908 mm)  
204 lb (93 kg)  
266 lb (121 kg)  
OM-808 Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 3 INSTALLATION  
3-1. Typical Multiple Operator System Component Relationships  
WARNING  
ELECTRIC SHOCK can kill; TWO TIMES NORMAL OPEN-CIRCUIT VOLTS exists between  
electrode holders of opposite polarity.  
Do not touch live electrical parts.  
Do not touch electrode holders of opposite polarity at the same time.  
Separate electrode holders of opposite polarity to prevent contact.  
Consult ANSI Z49.1 for common grounding safe practices.  
1
2
3
4
5
6
7
Common Work Connection  
Welding Power Source  
Line Disconnect Device  
Distribution Panel  
MOG-4 Pak Grid Rack  
Grid  
This view illustrates how system  
components are related.  
MOG-6 Grid Rack  
4
5
3
4
7
2
6
6
(+)  
( )  
DCEP  
DCEN  
1
S-0808-A  
OM-808 Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-2. Selecting A Location And Moving Resistance Grid Or Multi-Grid Rack  
Y
Turn Off welding power  
source BEFORE moving grid  
or rack.  
Locate grid(s) near welding power  
source.  
ResistanceGrid  
Have two persons of adequate physical  
strength lift individual grids at handles.  
1
18 in (460 mm) Open Space  
On Front Side  
Location should allow operation of  
controls.  
2
1
2
Handles  
Use handles to lift unit.  
Multi-Grid Rack  
3
Minimum 20 in (508 mm)  
Open Space On Front And  
Rear Sides  
Location should allow access to  
rear panel and removal of grids.  
Front  
4
Lifting Eyes  
Use four sets of lifting eyes to move  
rack.  
3
Rear  
4
Front  
4
Ref. ST-124 643-A / Ref. ST-151 556 / ST-161 154-A  
OM-808 Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-3. Weld Input/Output Cables For Resistance Grid (Dual Model Shown)  
Y
Turn Off welding power  
source, and disconnect in-  
put power before making any  
weld output connections.  
1
2
3
Weld Input Cable  
Work Cable  
Weld Output Cable  
If necessary, use Section 3-7 to  
select proper cable size.  
Use shortest cables possible.  
Do not use damaged cables.  
4
Terminal Lug  
9
Use lugs of proper amperage ca-  
pacity and hole size for connecting  
to common work, electrode hold-  
er(s), and weld output terminals (if  
applicable).  
8
5
Common Work Connection  
Connect work cable to common  
work according to codes.  
4
1
6
7
Insulated Electrode Holder  
GTAW Torch  
Install according to manufacturers  
instructions.  
2
8
8
Female Camlok Connector  
Install onto weld input cable as  
shown in Section 3-5.  
10  
5
9
Weld Input Receptacle  
Connect cable to weld input recep-  
tacle on rear panel of grid.  
4
10 Male Camlok Connector  
Install onto weld output cable as  
shown in Section 3-6.  
11 Electrode Receptacle  
11  
3
Connect electrode holder cable to  
Electrode receptacle.  
6
7
Or  
Tools Needed:  
S-0793  
OM-808 Page 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-4. Weld Input/Output Cables For Multi-Grid Rack  
1
2
3
Weld Input Cable  
Work Cable  
Y
Turn Off welding power source, and disconnect input  
power before making any weld output connections.  
Weld Output Cable  
If necessary, use Section 3-7 to  
select proper cable size.  
Use shortest cables possible.  
Do not use damaged cables.  
4
Terminal Lug  
Use lugs of proper amperage ca-  
pacity and hole size for connecting  
to common work, electrode hold-  
er(s), and weld output terminals (if  
applicable).  
5
Common Work Connection  
Connect work cable to common  
work according to codes.  
6
Input Terminal  
For models with polarity reversing,  
connect positive and negative  
cables to matching input terminal.  
6
For models without polarity revers-  
ing, only one input terminal is pro-  
vided. Connect electrode cable to  
input terminal.  
7
8
Insulated Electrode Holder  
GTAW Torch  
4
Install according to manufacturers  
instructions.  
9
Male Camlok Connector  
Install onto weld output cable as  
shown in Section 3-6.  
10 Electrode Receptacle  
Connect electrode holder cable to  
Electrode receptacle.  
4
1
2
5
9
4
10  
3
Tools Needed:  
7
8
Or  
S-0799-A  
OM-808 Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-5. Female Camlok Connector Assembly  
1
Weld Input Cable  
Strip insulation as shown.  
1
2
2
3
Copper Strip (Two Included)  
Connector Body  
4
Wrap strip around bare weld cable  
(use two on small diameter cable),  
and insert into connector body.  
3
4
Setscrew  
Tighten setscrew against copper  
strip.  
1 in  
(26 mm)  
5
6
Handle  
Pin  
6
Slide handle over connector body  
so holes align; secure by tapping  
pin into place.  
5
Tools Needed:  
7/32 in  
sb6.6* ST-159 028  
3-6. Male Camlok Connector Assembly  
1
Weld Output Cable  
Strip insulation as shown.  
2
3
Copper Strip  
Connector Body  
1
2
Wrap strip around bare weld cable  
(use two on small diameter cable),  
and insert into connector body.  
4
4
Setscrew  
3
Tighten setscrew against copper  
strip.  
5
6
Handle  
Pin  
1 in  
(26 mm)  
Slide handle over connector body  
so holes align; secure by tapping  
pin into place.  
6
5
Tools Needed:  
7/32 in  
sb6.4* 11/92 ST-155 015  
OM-808 Page 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-7. Weld Cable Size*  
Total Cable (Copper) Length In Weld Circuit Not Exceeding  
150 ft  
(45 m)  
200 ft  
(60 m)  
250 ft  
(70 m)  
300 ft  
(90 m)  
350 ft  
(105 m)  
400 ft  
(120 m)  
100 ft (30 m) Or Less  
10 To 60% 60 Thru 100%  
Welding  
Amperes  
10 Thru 100% Duty Cycle  
Duty Cycle  
Duty Cycle  
100  
150  
200  
250  
300  
350  
400  
500  
600  
700  
800  
4
4
3
4
2
3
2
1
1/0  
1/0  
3
1
1/0  
2/0  
3/0  
3/0  
3
2
1
1/0  
2/0  
3/0  
4/0  
4/0  
2
1
1/0  
2/0  
3/0  
3/0  
4/0  
2-2/0  
2-3/0  
2-3/0  
2/0  
3/0  
4/0  
2-2/0  
2-3/0  
2-3/0  
2-4/0  
3-3/0  
3-4/0  
3-4/0  
4-4/0  
2-2/0  
2-3/0  
2-4/0  
2-4/0  
3-3/0  
3-4/0  
4-4/0  
4-4/0  
1
1/0  
2/0  
2/0  
3/0  
4/0  
2-2/0  
2-2/0  
3/0  
4/0  
2-2/0  
2-3/0  
2-3/0  
2-4/0  
3-3/0  
3-4/0  
3-4/0  
1/0  
1/0  
2/0  
3/0  
4/0  
4/0  
4/0  
2-2/0  
2-2/0  
2-3/0  
2-4/0  
3-3/0  
3-4/0  
4/0  
2-2/0  
2-3/0  
2-4/0  
2-4/0  
*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.  
S-0007-D  
3-8. Optional Remote Receptacle Information And Connections  
1
Remote Receptacle  
Single models have one Remote  
receptacle RC3. Dual models have  
two Remote receptacles RC3 and  
RC4.  
2
3
Keyway  
Remote Grid Amperage  
Control  
4
5
Plug PLG1  
Threaded Collar  
To connect to this receptacle, align  
keyway, insert plug, and tighten  
threaded collar.  
4
3
5
REMOTE  
2
A
1
H
E
G
F
K
B
C
M
D
sb7.1 8/92* Ref. S-0166-A / ST-080 370-A  
OM-808 Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 4 OPERATION  
WARNING  
ELECTRIC SHOCK can kill.  
Keep all panels and covers securely in place.  
Do not touch electrode holders of opposite polarity at the same time.  
Separate electrode holders of opposite polarity to prevent contact.  
See ANSI Z49.1 and OSHA TITLE 29, CHAPTER XVII, PART 1910, Subpart Q.  
4-1. Controls (Dual Model Shown)  
1
2
Coarse Amperage Control  
Paralleling Switch  
1
2
1
Included on dual models only.  
3
4
Optional Polarity Switch  
2-1/2 Ampere Switch  
This switch is included on units with  
Polarity switch. Switch is optional  
for all other models.  
5
Fine Amperage Control  
3
4
4
5
5
Ref. ST-161 155  
4-2. Safety Equipment  
1
2
3
Wear the following while welding:  
1
2
Dry, Insulating Gloves  
Safety Glasses With Side  
Shields  
3
Welding Helmet With Correct  
Shade Of Filter (See ANSI  
Z49.1)  
sb3.1 1/94  
OM-808 Page 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-3. Work Clamp  
1
Work Clamp  
1
Connect work clamp to a clean,  
paint-freelocation on workpiece, as  
close to weld area as possible.  
Tools Needed:  
Use wire brush or sandpaper to  
clean metal at weld joint area. Use  
chipping hammer to remove slag  
after welding.  
sb4.1 2/93  
4-4. Optional Polarity Switch  
WARNING  
ELECTRIC SHOCK can kill; TWO TIMES  
NORMAL OPEN-CIRCUIT VOLTS exists  
between electrode holders of opposite  
polarity.  
ARCING can damage switch.  
Do not change Polarity switch position while welding  
or under load.  
Arcing inside switch can damage contacts, causing  
switch to fail.  
Do not touch live electrical parts.  
Do not touch electrode holders of opposite polarity  
at the same time.  
Separate electrode holders of opposite polarity to  
prevent contact.  
See ANSI Z49.1 and OSHA TITLE 29, CHAPTER  
XVII, PART 1910, Subpart Q.  
warn5.1* 2/93  
1
Polarity Switch  
Use switch to select polarity of weld  
output.  
For Direct Current Electrode Nega-  
tive (DCEN), use Straight (Str)  
position.  
For Direct Current Electrode Posi-  
tive (DCEP), use Reverse (Rev)  
position.  
1
Ref. ST-122 903-D  
OM-808 Page 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-5. Amperage Controls  
CAUTION  
ARCING can damage switch.  
Do not change position of any Amperage control or switch while welding or under load.  
Arcing inside switch can damage contacts, causing switch to fail.  
1
Coarse Amperage Control  
Use control to select coarse weld  
amperageoutput.  
To set amperage using only the  
Fine Amperage control, place  
Coarse Amperage control in Off  
position.  
2
2-1/2 Ampere Switch  
(Optional)  
Use switch to add 2-1/2 amperes to  
weld output.  
To add 2-1/2 amperes to weld  
output, place switch in Off position.  
For remote amperage adjustment,  
place switch in Off position.  
3
Fine Amperage Control  
Use control to add amperage, in 5  
ampere steps, to weld output.  
For remote amperage adjustment,  
place control in Off position.  
2
In Example:  
Total Amperage Output = 122.5 A  
(100 A + 2.5 A)  
3
OM-808 Page 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-6. Optional Remote Grid Amperage Control  
Remote amperage control only  
works when Fine Amperage control  
and optional 2-1/2 Ampere switch  
are in the Off position (see Section  
4-5).  
1
1
Remote Grid Amperage  
Control  
See Section 3-8 for installation.  
Fine Amperage Control  
2
Use control to add amperage, in 5  
ampere steps, to weld output.  
2
For front panel amperage adjust-  
ment, place control in Off position.  
3
2-1/2 Ampere Switch  
3
Use switch to add 2-1/2 amperes to  
weld output.  
To add 2-1/2 amperes to weld  
output, place switch in On position.  
For front panel amperage adjust-  
ment, place control in Off position.  
ST-080 370-A / Ref. ST-122 903-D  
4-7. Paralleling Switch (Dual Models Only)  
CAUTION  
ARCING can damage switch.  
Do not change Paralleling switch position while welding or under load.  
Arcing inside switch can damage contacts, causing switch to fail.  
warn5.1* 2/93  
1
ParallelingSwitch  
Use switch to select weld output at  
one or both Electrode terminals.  
For weld output at both Electrode  
terminals, place switch in Single  
position.  
For total weld output at the left  
Electrode terminal, place switch in  
Parallelposition. Output at the right  
terminal is 0 (zero).  
When switch is in Parallel position,  
all front panel amperage controls  
(left and right) adjust weld output  
(see Section 4-5).  
1
Ref. ST-122 903-D  
OM-808 Page 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4-8. Sequence Of Shielded Metal Arc Welding (SMAW)  
Install &  
Connect  
Equipment  
Select  
Electrode  
Put On  
Personal Safety  
Equipment  
Insert  
Electrode  
Into Holder  
Turn On  
Welding Power  
Source  
Set Controls  
Begin Welding  
ssb7.1 9/92  
4-9. Sequence Of Gas Tungsten Arc Welding (GTAW)  
Install &  
Connect  
Equipment  
If Applicable,  
Install High_  
Frequency Unit  
Select  
Tungsten  
Insert  
Tungsten  
Into Torch  
Put On  
Personal Safety  
Equipment  
Set Controls  
Turn On  
Shielding Gas  
If Applicable,  
Turn On High-  
Frequency Unit  
Turn On  
Welding Power  
Source  
Begin Welding  
ssb8.1* 12/92  
SECTION 5 MAINTENANCE & TROUBLESHOOTING  
5-1. Routine Maintenance  
Turn Off all power before maintaining.  
3 Months  
6 Months  
Tape Or  
Blow Out  
Replace  
Cracked  
Cables  
OR  
Or  
Vacuum  
Inside  
During Heavy Service,  
Clean Monthly  
Replace  
Unreadable  
Labels  
Clean  
And  
Tighten Weld  
Connections  
Ref. ST-124 643-A  
OM-808 Page 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5-2. Overload Protection  
Fuse link F1, or fuse links F1 and F2  
for dual models, protect the grid  
from overload damage. If weld  
output stops, check link(s) as  
follows:  
Grid Rear Panel  
Turn Off welding power source and  
disconnect input power.  
1
Fuse Link (See Parts List For  
Rating)  
Check and replace fuse link(s), if  
necessary.  
Close rear access door.  
1
Multi-Grid Rack  
Ref. ST-124 643-A / Ref. ST-161 156-A  
5-3. Troubleshooting  
Trouble  
Remedy  
No weld output.  
Check and replace open fuse link(s), if necessary (see Section 5-2).  
Check electrical input and output connections (see Section 3-3).  
Select correct size weld cables according to Section 3-7.  
Erratic or improper weld output.  
Clean and tighten weld cable connections (see Section 3-3).  
For dual models, be sure paralleling switch is in proper position (see Section 4-7).  
If using remote control, be sure Fine Amperage control and 2-1/2 Ampere switch on grid are in the Off  
position (see Section 4-5).  
OM-808 Page 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 6 ELECTRICAL DIAGRAMS  
SA-044 882-A  
Figure 6-1. Circuit Diagram For 300 Ampere Model  
SA-096 447-A  
Figure 6-2. Circuit Diagram For 300 Ampere Model With Polarity Reversing  
OM-808 Page 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SA-044 884-A  
Figure 6-3. Circuit Diagram For 400 Ampere Model  
SA-096 445-A  
Figure 6-4. Circuit Diagram For 400 Ampere Model With Polarity Reversing  
OM-808 Page 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SA-044 886-A  
Figure 6-5. Circuit Diagram For 250/250 Ampere Model  
SB-124 202  
Figure 6-6. Circuit Diagram For 250/250 Ampere Model With Polarity Reversing  
OM-808 Page 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SA-087 783-A  
Figure 6-7. Circuit Diagram For 350/350 Ampere Model  
SA-095 027-A  
Figure 6-8. Circuit Diagram For Remote Grid Controls  
OM-808 Page 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 7 PARTS LIST  
. Hardware is common and  
not available unless listed.  
ST-124 640-A  
Figure 7-1. Main Assembly  
OM-808 Page 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quantity  
Model  
300  
AC  
400  
250/250 350/350  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
A
A
AC A/B AC/BC A AC  
Figure 7-1. Main Assembly  
. . 1 . . . . . . . . . . . . 049 472 . . . RAIL, grid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2 . 2 . 2 . 2 . 2 . 2 . 2  
. . 2 . . . . . . . . . . . . 049 470 . . . BRACKET, side frame . . . . . . . . . . . . . . . . . . . . . . . 2 . 2 . 2 . 2 . 2 . 2 . 2 . 2  
. . 3 . . . . . . . . . . +049 590 . . . EXTENSION, handle . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1  
. . 4 . . . . . . . . . . +010 651 . . . PIN, spring 5/32 x 1 . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1  
. . 5 . . . . . . . . . . +049 497 . . . PANEL, mtg plrt switch . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1  
. . 6 . . . . . . . . . . +049 633 . . . TUBING, cop .540 OD x .123 wall x 1/2 . . . . . . . . . . . . . . . . . . . . . . . 2 . 2  
. . 7 . . . . . . . . . . . +049 611 . . . TUBING, cop .540 OD x .123 wall x 11/16 . . . . . . . . . . . . . . . . . . . . . 1 . 1  
. . 8 . . . . . . . . . . +049 610 . . . BUS BAR, switch pos 1/4 x 1 x 3-1/4 . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1  
. . 9 . . . . . . . . . . +049 602 . . . BUS BAR, input pos 1/4 x 1 x 7-5/8  
(400 APRC, 250/250 BPR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1  
. . 9 . . . . . . . . . . . . 089 721 . . . BUS BAR, input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . 9 . . . . . . . . . . +049 429 . . . BUS BAR, plrt 1/8 x 1 x 6-7/16 . . . . . . . . . . . . . . . . 1 . 1  
. . 9 . . . . . . . . . . . . 049 426 . . . BUS BAR, input single 1/4 x 3-3/8 x 7-1/4 . . . . . . . . . . 1  
. . 9 . . . . . . . . . . . . 049 503 . . . BUS BAR, input 1/4 x 3-7/16 x 4-13/16 . . . . . . . . . . . . . . . . . . . . 1 . . . . 1  
. . . . . . . . . . . . . . . +059 861 . . . BUS BAR, interconnect 1/8 x 1 x 3-13/16 . . . . . . . 1 . 1  
. . . . . . . . . . . . . . . . . 089 724 . . . BUS BAR, interconnect 3/16 x 1 x 7-1/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1  
. . . . . . . . . . . . . . . +049 433 . . . BUS BAR, input pos 1/4 x 1 x 9-3/4 . . . . . . . . . . . . . . . . 1  
. . 10 . . F1 . . . . *059 945 . . . FUSE, link 250A 250V . . . . . . . . . . . . . . . . . . . . . . . 2 . 2  
. . 10 . F1,2 . . *+059 945 . . . FUSE, link 250A 250V . . . . . . . . . . . . . . . . . . . . . . . 4 . 4  
. . 10 . . F1 . . . . *027 267 . . . FUSE, link 300A 250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2  
. . 10 . F1,2 . . *+027 267 . . . FUSE, link 300A 250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . 4  
. . 10 . . F1 . . . . *059 943 . . . FUSE, link 350A 250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2  
. . 10 . F1,2 . . *+059 943 . . . FUSE, link 350A 250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . 4  
. . 10 . . F1 . . . . *086 042 . . . FUSE, link 400A 250V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . 3  
. . 11 . . . . . . . . . +049 608 . . . BUS BAR, common 1/4 x 1 x 11-7/8 . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1  
. . 12 . . . . . . . . . . . 059 805 . . . TUBING, cop 540 OD x .123 wall x 5/16 . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1 . . . . . .  
. . 13 . . . . . . . . . . . 010 907 . . . NUT, locking 1 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1  
. . 13 . . . . . . . . . +010 907 . . . NUT, locking 1 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2 . . . . 2  
. . 14 . . . . . . . . . . . 010 854 . . . NUT, speed No. 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1  
. . 15 . . . . . . . . . . . 056 271 . . . RECEPTACLE, twlk male . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1  
. . 15 . . . . . . . . . +056 271 . . . RECEPTACLE, twlk male . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2 . . . . 2  
. . 16 . . . . . . . . . . . 039 633 . . . CONNECTOR, quick connect twlk female . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1  
. . 16 . . . . . . . . . +039 633 . . . CONNECTOR, quick connect twlk female . . . . . . . . . . 2 . . . . 2 . . . . 2 . . . . . .  
. . 17 . . . . . . . . . . . 010 853 . . . FASTENER, scr slotted hd No. 2 . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1  
. . 18 . . . . . . . . . . . 010 855 . . . RETAINER, scr No. 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1  
. . 19 . . . . . . . . . . . 049 500 . . . PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1  
. . . . . . . . . . . . . . . . . 080 381 . . . COVER, camlock opening . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1  
. . 20 . . . . . . . . . +049 428 . . . BUS BAR, interconnect 1/8 x 1 x 1-1/4 . . . . . . . . . 1 . 1  
. . 20 . . . . . . . . . +049 607 . . . BUS BAR, switch neg 1/4 x 1 x 1-1/2 . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1  
. . 21 . . . . . . . . . . . 059 857 . . . BUS BAR, plrt single 1/8 x 1 x 7-5/8 . . . . . . . . . . . . . . . 1  
. . 21 . . . . . . . . . +049 431 . . . BUS BAR, input neg 1/8 x 1 x 3-7/8 . . . . . . . . . . . . . . . . 1 . .  
. . 21 . . . . . . . . . . . 059 852 . . . BUS BAR, plrt single 1/4 x 1 x 7-5/8 . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . . 1  
. . 21 . . . . . . . . . +049 604 . . . BUS BAR, input neg 1/4 x 1 x 3-1/4 . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1  
. . 22 . . . . . . . . . . . 134 327 . . . LABEL, warning general precautionary . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1  
. . 23 . . . . . . . . ++049 504 . . . WRAPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1  
. . 24 . . S3 . . . +049 434 . . . SWITCH, plrt reverse . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1  
. . 24 . . S3 . . . +049 612 . . . SWITCH, plrt reverse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1  
. . 24 . . S3 . . . +049 612 . . . SWITCH, plrt reverse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1  
. . . . . . . . . . . . . . . +049 633 . . . PIPE, cop 1/4 x 1/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1  
. . . . . . . . . . . . . . . . +049 611 . . . PIPE, cop 1/4 x 11/16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . 2 . 3 . 1  
. . 25 . . . . . . . . . . . 049 496 . . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 1 . . . . . 1  
. . 26 . . . . . . . . . . . 049 469 . . . HANDLE, carrying . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2 . 2 . 2 . 2 . 2 . 2 . 2  
. . 27 . . . . . . . . . . . 107 734 . . . ANGLE, mtg bracket (also APR & BPR) . . . . . . . . 1 . . . . . 1 . . . . . 1 . . . . . 1  
. . 28 . . . . . . . . . +059 866 . . . HANDLE, switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1  
. . 29 . . . . . . . . . +010 647 . . . PIN, spring 5/32 x 1-1/4 . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1  
. . 30 . . . . . . . . . . . . Fig 7-2 . . . PANEL, front w/components . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1 . 1 . 1  
OM-808 Page 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quantity  
Model  
300  
AC  
400  
250/250 350/350  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
A
A
AC A/B AC/BC A AC  
Figure 7-1. Main Assembly (Continued)  
. . 31 . . . . . . . . . . . 049 563 . . . RESISTOR ASSEMBLY, current (Fig 3) . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1 . 1 . 1  
. . 31 . . . . . . . . . . . 049 615 . . . RESISTOR ASSEMBLY, current (Fig 3) . . . . . . . . . . . . . . . . 1 . 1  
. . 31 . . . . . . . . . . . 049 562 . . . RESISTOR ASSEMBLY, current (Fig 3) . . . . . . . . . . . . . . . . . . . . . . . 1 . 1  
. . 31 . . . . . . . . . . . 089 729 . . . RESISTOR ASSEMBLY, current (Fig 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1  
. . . . . . . . . . . . . . . . . 600 322 . . . CABLE, weld No. 2/0 (also 300APR)  
(order by ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3ft  
. . . . . . . . . . . . . . . . . 600 323 . . . CABLE, weld No. 3 (also 250/250BPR & 400APR)  
(order by ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3ft . . . 3ft . . . 3ft  
+PR models only.  
*Recommended Spare Parts.  
++When ordering a component originally displaying a precautionary label, the label should also be ordered.  
To maintain the factory original performance of your equipment, use only Manufacturers Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
. Hardware is common and  
not available unless listed.  
7
8
6
9
10  
11  
15  
12  
13  
14  
5
4
1
2
3
5
4
16  
7
8
17  
18  
19  
1
21  
20  
24 23  
22  
ST-124 641-A  
Figure 7-2. Panel, Front w/Components  
OM-808 Page 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quantity  
Model  
300  
AC  
400  
250/250 350/350  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
A
A
AC A/B AC/BC A AC  
Figure 7-2. Panel, Front w/Components  
(Fig 7-1 Item 30)  
. . 1 . . . S4 . . . 011 609 . . . SWITCH, tgl SPDT 15A 125V . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1  
. . 1 . . S8,9 . . 011 609 . . . SWITCH, tgl SPDT 15A 125V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2  
. . 2 . . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE,  
(order by model and serial number) . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1 . 1 . 1  
. . 3 . . . . . . . . . . . . 049 486 . . . PANEL, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1 . 1 . 1  
. . 4 . . . . . . . . . . . . 059 804 . . . TUBING, cop 1/4 IPS x 7/16 . . . . . . . . . . . . . . . . . . 2 . 2 . 4 . 4 . 3 . 3 . 6 . 6  
. . 5 . . . . . . . . . . . . 059 805 . . . TUBING, cop 1/4 IPS x 5/16 . . . . . . . . . . . . . . . . . . 1 . 1 . . . . . . . . 3 . 3 . 3 . 3  
. . 5 . . . . . . . . . . . . 059 803 . . . TUBING, cop 1/4 IPS x 3/16 . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1  
. . 6 . . . S2 . . . . . 049 560 . . . SWITCH, current LH high . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1  
. . 6 . . . S2 . . . . . 089 727 . . . SWITCH, current LH high . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1  
. . 7 . . . . . . . . . . . . 059 875 . . . TUBING, 3/8 OD x 0.256 ID x 7/16 . . . . . . . . . . . . 1 . 1  
. . 7 . . . . . . . . . . . . 059 876 . . . TUBING, 3/8 OD x 0.256 ID x 11/16 . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2  
. . 8 . . . . . . . . . . . . 059 874 . . . TUBING, 3/8 OD x 0.256 ID x 1-3/8 . . . . . . . . . . . 1 . 1  
. . 8 . . . . . . . . . . . . 010 199 . . . TUBING, 0.275 ID x 0.048 wall x 1 . . . . . . . . . . . . . . . . . . . . 1 . 1 . . . . . . . . 2 . 2  
. . 8 . . . . . . . . . . . . 059 873 . . . TUBING, 3/8 OD x 0.256 ID x 1-5/8 . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2  
. . 9 . . . . . . . . . . . . 049 477 . . . BUS BAR, output 1/8 x 1 x 7-1/8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1  
. . 10 . . . . . . . . . . . 049 567 . . . BUS BAR, output 1/8 x 1 x 5-9/16 . . . . . . . . . . . . . 1 . 1 . 2 . 2 . 1 . 1 . 1 . 1  
. . 11 . . S5 . . . . . 049 571 . . . SWITCH, paralleling (if applicable) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1  
. . 12 . . . . . . . . . . . 059 872 . . . TUBING, 3/8 OD x 0.256 ID x 2-1/2 . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2 . 2 . 2  
. . 13 . . . . . . . . . . . 049 568 . . . BUS BAR, output 1/8 x 1 x 5-9/16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1  
. . 14 . . . . . . . . . . . 049 569 . . . BUS BAR, interconnect 1/8 x 1 x 2-1/4 . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1  
. . 15 . . . . . . . . . . . 049 485 . . . BAFFLE, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 1 . 1  
. . 15 . . . . . . . . . . . 089 732 . . . BAFFLE, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1  
. . 16 . . S1 . . . . . 059 734 . . . SWITCH, current 10posn . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1  
. . 16 . S1,3 . . . . 059 734 . . . SWITCH, current 10posn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2 . 2 . 2  
. . 17 . . S2 . . . . . 049 435 . . . SWITCH, current high . . . . . . . . . . . . . . . . . . . . . . . 1 . 1  
. . 17 . . S2 . . . . . 049 613 . . . SWITCH, current high . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1  
. . 17 . . S4 . . . . . 049 561 . . . SWITCH, current RH high . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1  
. . 17 . . S4 . . . . . 089 728 . . . SWITCH, current RH high . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1  
. . 18 . RC3 . . 039 718 . . . RECEPTACLE, 10skt MS-3102A-18-1S . . . . . . . . 1 . 1 . 1 . 1  
. . 18 . RC3,4 . 039 718 . . . RECEPTACLE, 10skt MS-3102A-18-1S . . . . . . . . . . . . . . . . . . . . . . . 2 . 2 . 2 . 2  
. . 19 . . . . . . . . . . . 010 907 . . . NUT, locking 1 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 2 . 2 . 2 . 2  
. . 20 . . . . . . . . . . . 006 790 . . . KNOB, switch fine . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 2 . 2 . 2 . 2  
. . 21 . RC1 . . . . 039 628 . . . RECEPTACLE, twlk insul . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1  
. . 21 . RC1,2 . . . 039 628 . . . RECEPTACLE, twlk insul . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . 2 . 2 . 2  
. . 22 . . . . . . . . . . . 039 630 . . . PLUG, male twlk insul . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 2 . 2 . 2 . 2  
. . 23 . . . . . . . . . . . 010 647 . . . PIN, spring 5/32 x 1-1/4 . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 3 . 3 . 3 . 3  
. . 24 . . . . . . . . . . . 059 773 . . . HANDLE, switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . 1 . 1 . 1 . 3 . 3 . 3 . 3  
Parts for optional equipment.  
+PR models only.  
To maintain the factory original performance of your equipment, use only Manufacturers Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-808 Page 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quantity  
Model  
300  
400 250/250 350/350  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
049 563 049 615 049 562  
089 729  
Figure 7-3. Resistor Assembly, Current  
(Fig 7-1 Item 31)  
. . 1 . . . . . . . . . . . . . . . . 049 479 . . BUS BAR, connecting resistors . . . . . . . . . . . 1 . . . . 5 . . . . 6 . . . . . . 2  
. . . . . . . . . . . . . . . . . . . . . 059 841 . . BUS BAR, connecting resistors . . . . . . . . . . . . . . . . . . 1  
. . 2 . . . . . . R1 . . . . . . 059 797 . . RESISTOR, 5A . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1  
. . 2 . . . . . R4,14 . . . . . 059 797 . . RESISTOR, 5A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . . . 2  
. . 3 . . . . . R5-7 . . . . . 059 800 . . RESISTOR, 25A . . . . . . . . . . . . . . . . . . . . . . . 10  
. . 3 . . . . . R5-8 . . . . . 059 800 . . RESISTOR, 25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
. . 3 . . . R1-3,8-10 . . . 059 800 . . RESISTOR, 25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
. . 3 . . . R1-3,8-10 . . . 059 800 . . RESISTOR, 25A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24  
. . . . . . . . . . . . . . . . . . . . . 059 726 . . INSULATOR, end . . . . . . . . . . . . . . . . . . . . . . 28 . . . 36 . . . 48 . . . . . 64  
. . . . . . . . . . . . . . . . . . . . . 059 728 . . INSULATOR, support . . . . . . . . . . . . . . . . . . . 22 . . . 30 . . . 36 . . . . . 52  
. . . . . . . . . . . . . . . . . . . . . 059 727 . . INSULATOR, support 5/8 bore . . . . . . . . . . . . 6 . . . . 6 . . . 12 . . . . . 12  
. . . . . . . . . . . . . . . . . . . . . 059 724 . . RING, retaining ext .886 x 0.021 . . . . . . . . . 34 . . . 42 . . . 60 . . . . . 76  
. . . . . . . . . . . . . . . . . . . . . 059 725 . . RING, retaining ext 1.379 x 0.025 . . . . . . . . 22 . . . 30 . . . 36 . . . . . 52  
. . 4 . . . . . . . . . . . . . . . . 049 476 . . BUS BAR, connecting resistors . . . . . . . . . . . 1 . . . . 1 . . . . 2  
. . 5 . . . . . . . . . . . . . . . . 049 475 . . BUS BAR, connecting resistors . . . . . . . . . . . 1 . . . . 1 . . . . 2  
. . 6 . . . . . . . . . . . . . . . . 049 481 . . BUS BAR, connecting resistors . . . . . . . . . . . 4 . . . . 4 . . . . 4 . . . . . . 2  
. . 7 . . . . . . . . . . . . . . . . 049 478 . . BUS BAR, connecting resistors . . . . . . . . . . . 1 . . . . 2 . . . . 2 . . . . . . 4  
. . . . . . . . . . . . . . . . . . . . . 089 725 . . BUS BAR, connecting resistors (6 hole) . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
. . . . . . . . . . . . . . . . . . . . . 089 723 . . BUS BAR, connecting resistors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . 089 726 . . BUS BAR, connecting resistors (6 hole) . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
7
. Hardware is common and  
6
not available unless listed.  
1
5
4
7
8
1
6
4
3
2
9
5
1
14  
16  
15  
1
6
1
10  
11  
14  
12  
13  
12  
SC-124 642  
10  
Figure 7-3. Resistor Assembly, Current  
OM-808 Page 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quantity  
Model  
300  
400 250/250 350/350  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
049 563 049 615 049 562  
089 729  
Figure 7-3. Resistor Assembly, Current  
(Fig 1 Item 31)  
. . 8 . . . . . . . . . . . . . ♦♦049 570 . . BUS BAR, interconnecting resistors . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . .  
. . 8 . . . . . . . . . . . . . . . . 049 570 . . BUS BAR, interconnecting resistors . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . 2  
. . 9 . . . . . . . . . . . . . . . . 049 480 . . BUS BAR, connecting resistors . . . . . . . . . . . 1 . . . . 1 . . . . 2  
. . 10 . . . . . . . . . . . . . 057 430 . . WASHER, centering No. 18 . . . . . . . . . . . . . . 2 . . . . 2 . . . . 4  
. . 11 . . . . . . . . . . . . . 081 016 . . BRACKET, mtg resistor . . . . . . . . . . . . . . . . . . 1 . . . . 1 . . . . 2  
. . 12 . . . . . . . . . . . . . 059 933 . . WASHER, mica 3/4 ID x 1-1/2 OD . . . . . . . . 2 . . . . 2 . . . . 4  
. . 13 . . . . . R8 . . . . 059 932 . . RESISTOR, WW fxd 175W 20 ohm . . . . . . . 1  
. . 13 . . . . . R9 . . . . 059 932 . . RESISTOR, WW fxd 175W 20 ohm . . . . . . . . . . . . . . 1  
. . 13 . . . R15,16 . . 059 932 . . RESISTOR, WW fxd 175W 20 ohm . . . . . . . . . . . . . . . . . . . . . 2  
. . 14 . . . . R2,3 . . . . . 059 798 . . RESISTOR, 10A . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . 2  
. . 14 . R5,6,12,13 . . 059 798 . . RESISTOR, 10A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . . . . . . 4  
. . 15 . . . . . . . . . . . . . 604 714 . . BOLT, carriage 1/4-20 x 9 . . . . . . . . . . . . . . . . 2 . . . . 2 . . . . 2  
. . 16 . . . . . R4 . . . . . . 059 799 . . RESISTOR, 20A . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . 1  
. . 16 . . . . R7,11 . . . . . 059 799 . . RESISTOR, 20A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . . . 2  
♦♦Not part of this assembly.  
These parts are optional on all units not equipped with factory installed polarity switch.  
To maintain the factory original performance of your equipment, use only Manufacturers Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-808 Page 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
. Hardware is common and  
not available unless listed.  
1
2
3
4
5
6
7
8
9
12  
11  
10  
SD-080 254-E  
Figure 7-4. MOG-Pak 6 APR  
OM-808 Page 32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quantity  
PAK 4A  
PAK 2A  
PAK 6A  
Item  
No.  
Part  
No.  
Single  
Dual  
Single  
Dual  
Single  
Dual  
Description  
Polarity Polarity Polarity Polarity Polarity Polarity  
Figure 7-4. MOG-Pak 2, 4, & 6  
1
1
1
2
3
3
3
4
4
4
5
6
6
6
6
6
6
049 758 ANGLE, guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 690 ANGLE, guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 541 ANGLE, guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
123 154 LABEL, general precautionary . . . . . . . . . . . . . . . . . . . . . . . .  
+085 342 ROOF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
+085 341 ROOF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
+085 340 ROOF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 771 FRAME, grid rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 706 FRAME, grid rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 545 FRAME, grid rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 540 PANEL, baffle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 770 TERMINAL ASSEMBLY, plrt single (consisting of) . . . . . . .  
049 769 TERMINAL ASSEMBLY, plrt dual (consisting of) . . . . . . . .  
049 708 TERMINAL ASSEMBLY, plrt single (consisting of) . . . . . . .  
049 707 TERMINAL ASSEMBLY, plrt dual (consisting of) . . . . . . . .  
049 535 TERMINAL ASSEMBLY, plrt single (consisting of) . . . . . . .  
049 534 TERMINAL ASSEMBLY, plrt dual (consisting of) . . . . . . . .  
049 768 · TERMINAL BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 709 · TERMINAL BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 533 · TERMINAL BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 757 · STRIP, mtg term . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
080 183 · STRIP, mtg term . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
080 186 · STRIP, mtg term LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
080 187 · STRIP, mtg term RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
602 216 · WASHER, lock split 1/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
601 879 · NUT, brs hex full 1/2-13 . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 767 PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 703 PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 536 PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
027 529 PIN, cotter 1/4 x 3-1/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 766 PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 700 PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 539 PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
059 872 TUBING, stl 3/8 OD x 0.256 ID x 2-1/2 . . . . . . . . . . . . . . . .  
010 199 TUBING, stl 0.275 ID x 0.048 wall x 1 . . . . . . . . . . . . . . . . .  
080 139 SCREW, flat hd 1/4-20 x 6 . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
2
1
1
1
1
2
2
2
2
1
2
2
1
1
1
1
2
1
1
7
7
7
8
9
9
9
10  
11  
12  
1
2
1
1
2
1
1
3
1
3
2
1
2
1
1
4
8
4
1
4
8
4
4
8
4
4
8
4
4
8
4
4
8
4
Optional Equipment  
6
6
6
6
6
6
085 349 TERMINAL ASSEMBLY, plrt single (consisting of) . . . . . . .  
085 346 TERMINAL ASSEMBLY, plrt dual (consisting of) . . . . . . . .  
085 351 TERMINAL ASSEMBLY, plrt single (consisting of) . . . . . . .  
085 347 TERMINAL ASSEMBLY, plrt dual (consisting of) . . . . . . . .  
085 350 TERMINAL ASSEMBLY, plrt single (consisting of) . . . . . . .  
085 348 TERMINAL ASSEMBLY, plrt dual (consisting of) . . . . . . . .  
049 768 · TERMINAL BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 709 · TERMINAL BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
049 533 · TERMINAL BOARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
085 331 · STRIP, mtg term . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
085 332 · STRIP, mtg term . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
085 333 · STRIP, mtg term . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
085 334 · STRIP, mtg term . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1
1
1
1
1
1
1
1
1
1
2
1
1
1
2
1
1
1
1
+When ordering a component originally displaying a precautionary label, the label should also be ordered.  
To maintain the factory original performance of your equipment, use only Manufacturers Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-808 Page 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quantity  
Model  
Item  
No.  
Part  
No.  
Description  
2.5 Amp 5 Amp  
Figure 7-5. Remote Control  
. 1 . . . . . . . . 080 194 . . . WRAPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1  
. . . . . . . . . . . . 138 033 . . . CONNECTOR, circ clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1  
. 2 . . . . . . . . 600 798 . . . CABLE, No. 16 10/c (order by ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100ft . . . 100ft  
. 3 . . . . . . . . 039 736 . . . CLAMP, cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1  
. 4 . . . . . . . . 039 716 . . . CONNECTOR, circ 10 pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1  
. 5 . . . . . . . . 080 198 . . . CASE SECTION, base/front/rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE (order by model number) . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1  
. 6 . . . . . . . . 006 790 . . . KNOB, switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1  
. . . . . . . . . . . . 059 734 . . . SWITCH, current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1  
. 7 . . . . . . . . 053 359 . . . SWITCH, tgl SPST 20A 125V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . 1  
2
1
3
4
7
6
. Hardware is common and  
not available unless listed.  
5
SA-080 370-A  
Figure 7-5. Remote Control  
To maintain the factory original performance of your equipment, use only Manufacturers Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-808 Page 34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Effective January 1, 2000  
(Equipment with a serial number preface of LAor newer)  
This limited warranty supersedes all previous Miller warranties and is exclusive with no other  
guarantees or warranties expressed or implied.  
Warranty Questions?  
LIMITED WARRANTY Subject to the terms and conditions  
below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants  
to its original retail purchaser that new Miller equipment sold  
after the effective date of this limited warranty is free of defects  
in material and workmanship at the time it is shipped by Miller.  
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE  
WARRANTIES OF MERCHANTABILITY AND FITNESS.  
*
APT, ZIPCUT & PLAZCUT Model Plasma Cutting  
Torches  
Call  
1-800-4-A-MILLER  
for your local  
Miller distributor.  
*
*
*
*
*
Remote Controls  
Accessory Kits  
Replacement Parts (No labor)  
Spoolmate 185 & Spoolmate 250  
Canvas Covers  
Within the warranty periods listed below, Miller will repair or  
replace any warranted parts or components that fail due to  
such defects in material or workmanship. Miller must be  
notified in writing within thirty (30) days of such defect or  
failure, at which time Miller will provide instructions on the  
warranty claim procedures to be followed.  
Your distributor also gives  
you ...  
Millers True Blue Limited Warranty shall not apply to:  
1. Consumable components; such as contact tips,  
cutting nozzles, contactors, brushes, slip rings,  
relays or parts that fail due to normal wear.  
Service  
You always get the fast,  
reliable response you  
need. Most replacement  
parts can be in your  
hands in 24 hours.  
Miller shall honor warranty claims on warranted equipment  
listed below in the event of such a failure within the warranty  
time periods. All warranty time periods start on the date that  
the equipment was delivered to the original retail purchaser, or  
one year after the equipment is sent to a North American  
distributor or eighteen months after the equipment is sent to an  
International distributor.  
2. Items furnished by Miller, but manufactured by others,  
such as engines or trade accessories. These items are  
covered by the manufacturers warranty, if any.  
Support  
3. Equipment that has been modified by any party other  
than Miller, or equipment that has been improperly  
installed, improperly operated or misused based upon  
industry standards, or equipment which has not had  
reasonable and necessary maintenance, or equipment  
which has been used for operation outside of the  
specifications for the equipment.  
Need fast answers to the  
tough welding questions?  
Contact your distributor.  
The expertise of the  
distributor and Miller is  
there to help you, every  
step of the way.  
1. 5 Years Parts 3 Years Labor  
*
*
Original main power rectifiers  
Inverters (input and output rectifiers only)  
MILLER PRODUCTS ARE INTENDED FOR PURCHASE  
AND USE BY COMMERCIAL/INDUSTRIAL USERS AND  
PERSONS TRAINED AND EXPERIENCED IN THE USE  
AND MAINTENANCE OF WELDING EQUIPMENT.  
2. 3 Years Parts and Labor  
*
*
*
*
*
*
Transformer/Rectifier Power Sources  
Plasma Arc Cutting Power Sources  
Semi-Automatic and Automatic Wire Feeders  
Inverter Power Supplies  
In the event of a warranty claim covered by this warranty, the  
exclusive remedies shall be, at Millers option: (1) repair; or (2)  
replacement; or, where authorized in writing by Miller in  
appropriate cases, (3) the reasonable cost of repair or  
replacement at an authorized Miller service station; or (4)  
payment of or credit for the purchase price (less reasonable  
depreciation based upon actual use) upon return of the goods  
at customers risk and expense. Millers option of repair or  
replacement will be F.O.B., Factory at Appleton, Wisconsin, or  
F.O.B. at a Miller authorized service facility as determined by  
Miller. Therefore no compensation or reimbursement for  
transportation costs of any kind will be allowed.  
Intellitig  
Engine Driven Welding Generators  
(NOTE: Engines are warranted separately by  
the engine manufacturer.)  
3. 1 Year Parts and Labor  
*
*
DS-2 Wire Feeder  
Motor Driven Guns (w/exception of Spoolmate  
185 & Spoolmate 250)  
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES  
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE  
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR  
DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR  
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF  
PROFIT), WHETHER BASED ON CONTRACT, TORT OR  
ANY OTHER LEGAL THEORY.  
*
*
*
*
*
*
*
*
*
*
*
*
*
*
Process Controllers  
Positioners and Controllers  
Automatic Motion Devices  
RFCS Foot Controls  
Induction Heating Power Sources  
Water Coolant Systems  
HF Units  
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN  
AND ANY IMPLIED WARRANTY, GUARANTY OR  
REPRESENTATION AS TO PERFORMANCE, AND ANY  
REMEDY FOR BREACH OF CONTRACT TORT OR ANY  
OTHER LEGAL THEORY WHICH, BUT FOR THIS  
Grids  
Maxstar 140  
PROVISION,  
MIGHT  
ARISE  
BY  
IMPLICATION,  
Spot Welders  
OPERATION OF LAW, CUSTOM OF TRADE OR COURSE  
OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR PARTICULAR  
PURPOSE, WITH RESPECT TO ANY AND ALL  
EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND  
DISCLAIMED BY MILLER.  
Load Banks  
Miller Cyclomatic Equipment  
Running Gear/Trailers  
Plasma Cutting Torches (except APT & SAF  
Models)  
Some states in the U.S.A. do not allow limitations of how long  
an implied warranty lasts, or the exclusion of incidental,  
indirect, special or consequential damages, so the above  
limitation or exclusion may not apply to you. This warranty  
provides specific legal rights, and other rights may be  
available, but may vary from state to state.  
*
Field Options  
(NOTE: Field options are covered under True  
Blue for the remaining warranty period of the  
product they are installed in, or for a minimum of  
one year whichever is greater.)  
In Canada, legislation in some provinces provides for certain  
additional warranties or remedies other than as stated herein,  
and to the extent that they may not be waived, the limitations  
and exclusions set out above may not apply. This Limited  
Warranty provides specific legal rights, and other rights may  
be available, but may vary from province to province.  
4. 6 Months Batteries  
5. 90 Days Parts  
*
*
MIG Guns/TIG Torches  
Induction Heating Coils and Blankets  
miller_warr 7/00  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Owners Record  
Please complete and retain with your personal records.  
Model Name  
Purchase Date  
Distributor  
Address  
Serial/Style Number  
(Date which equipment was delivered to original customer.)  
City  
State  
Zip  
For Service  
to locate a DISTRIBUTOR or SERVICE AGENCY near you.  
Always provide Model Name and Serial/Style Number.  
Contact your Distributor for:  
Welding Supplies and Consumables  
Options and Accessories  
Personal Safety Equipment  
Service and Repair  
Miller Electric Mfg. Co.  
An Illinois Tool Works Company  
1635 West Spencer Street  
Appleton, WI 54914 USA  
Replacement Parts  
Training (Schools, Videos, Books)  
International HeadquartersUSA  
USA Phone: 920-735-4505 Auto-Attended  
USA & Canada FAX: 920-735-4134  
International FAX: 920-735-4125  
Technical Manuals (Servicing Information  
and Parts)  
Circuit Diagrams  
European Headquarters –  
United Kingdom  
Phone: 44 (0) 1204-593493  
FAX: 44 (0) 1204-598066  
Welding Process Handbooks  
www.MillerWelds.com  
Contact the Delivering Carrier for:  
File a claim for loss or damage during  
shipment.  
For assistance in filing or settling claims,  
contact your distributor and/or equipment  
manufacturers Transportation Department.  
PRINTED IN USA  
2000 Miller Electric Mfg. Co. 6/00  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Cooktop 2011 User Manual
MTD Log Splitter 242 642A User Manual
NETGEAR Network Router D7000 User Manual
Niles Audio Personal Lift CM650BG User Manual
NorthStar Navigation GPS Receiver 941X User Manual
Orbit Manufacturing Weather Radio 57069 User Manual
Outback Power Systems Surge Protector FW SP 250 User Manual
Palm Cell Phone Z22 User Manual
Panasonic Vacuum Cleaner MC CL935 User Manual
Patton electronic IP Phone 4970 4980 4990 User Manual