| OM-186 895G   June 1999   Processes   MIG (GMAW) Welding   Flux Cored (FCAW) Welding   Description   Wire Feeder   I-22A & I-24A   Visit our website at   Download from Www.Somanuals.com. All Manuals Search And Download.   TABLE OF CONTENTS   SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . .   1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . . .   1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   SECTION 1 − CONSIGNES DE SECURITE − LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . .   1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   1-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   1 1 1 3 3 4 5 5 5 WARNING   This product, when used   for welding or cutting,   produces fumes or   gases which contain   chemicals known to the   State of California to   cause birth defects and,   in some cases, cancer.   (California Health &   Safety Code Section   25249.5 et seq.)   1-3 Dangers supplémentaires en relation avec l’installation, le fonctionnement   et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   7 8 8 9 9 1-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   1-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   SECTION 2 − DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2-1. Warning Label Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2-2. Rating Label For CE Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2-3. Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   10   10   SECTION 3 − INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11   3-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-2. Site Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-3. Gun Recommendation Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-4. Equipment Connection Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-5. 14-Pin Receptacle, Shielding Gas And Optional Volt Sense Lead . . . . . . . . . . . . . . . . . . . . . .   3-6. 14-Pin Receptacle Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-7. Connecting Welding Gun And Weld Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-8. Optional Meter Circuit Board Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-9. Motor Start/Burnback Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-10.Installing Wire Guide And Drive Roll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   3-11.Installing And Threading Welding Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   11   11   12   12   12   13   13   14   15   16   17   SECTION 4 − OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18   4-1. Front Panel Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   4-2. Optional Side Panel Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   18   19   SECTION 5 − MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19   5-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   5-2. Overload Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   5-3. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   19   20   20   SECTION 6 − ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22   SECTION 7 − PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23   OPTIONS AND ACCESSORIES   WARRANTY   OM-186 895   Download from Www.Somanuals.com. All Manuals Search And Download.   Declaration of Conformity for   European Community (CE) Products   This information is provided for units with CE certification (see rating label on unit).   NOTE   Manufacturer’s Name:   Miller Electric Mfg. Co.   1635 W. Spencer Street   Appleton, WI 54914 USA   Manufacturer’s Address:   Declares that the product:   I-22A And I-24A   conforms to the following Directives and Standards:   Directives   Low Voltage Directive: 73/23/EEC   Electromagnetic Compatibility (EMC) Directive: 89/336/EEC   Machinery Directives: 89/392/EEC, 91/368/EEC, 93/C 133/04, 93/68/EEC   Standards   Arc Welding Equipment Part I: Welding Power Sources: IEC 974-1   (April 1995 − Draft Revision)   Arc Welding Equipment: Wirefeed Systems: IEC 974-4   (May 1995 − Draft Revision)   Degrees of Protection Provided By Enclosures (IP Code): IEC 529:1989   Insulation Coordination For Equipment With Low-Voltage Systems:   Part I: Principles, Requirements and Tests: IEC 664-1: 1992   Electromagnetic Compatibility, (EMC): EN 50199   European Contact:   Mr. Luigi Vacchini, Managing Director   MILLER Europe S.P.A.   Via Privata Iseo   20098 San Giuliano   Milanese, Italy   Telephone:   Fax:   39(02)98290-1   39(02)98281-552   dec_con1 1/96   Download from Www.Somanuals.com. All Manuals Search And Download.   SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING   som _nd_5/97   1-1. Symbol Usage   Means Warning! Watch Out! There are possible hazards   with this procedure! The possible hazards are shown in   the adjoining symbols.   This group of symbols means Warning! Watch Out! possible   ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.   Consult symbols and related instructions below for necessary actions   to avoid the hazards.   Y Marks a special safety message.   . Means “Note”; not safety related.   1-2. Arc Welding Hazards   Y The symbols shown below are used throughout this manual to   call attention to and identify possible hazards. When you see   the symbol, watch out, and follow the related instructions to   avoid the hazard. The safety information given below is only   a summary of the more complete safety information found in   Safety Standards.   D D D If earth grounding of the workpiece is required, ground it directly   with a separate cable − do not use work clamp or work cable.   Do not touch electrode if you are in contact with the work, ground,   or another electrode from a different machine.   Use only well-maintained equipment. Repair or replace damaged   parts at once. Maintain unit according to manual.   D D D Wear a safety harness if working above floor level.   Keep all panels and covers securely in place.   Y Y Only qualified persons should install, operate, maintain, and   repair this unit.   During operation, keep everybody, especially children, away.   Clamp work cable with good metal-to-metal contact to workpiece   or worktable as near the weld as practical.   D D Insulate work clamp when not connected to workpiece to prevent   contact with any metal object.   ELECTRIC SHOCK can kill.   Do not connect more than one electrode or work cable to any   single weld output terminal.   Touching live electrical parts can cause fatal shocks   or severe burns. The electrode and work circuit is   electrically live whenever the output is on. The input   power circuit and machine internal circuits are also   SIGNIFICANT DC VOLTAGE exists after removal of   input power on inverters.   live when power is on. In semiautomatic or automatic wire welding, the   wire, wire reel, drive roll housing, and all metal parts touching the   welding wire are electrically live. Incorrectly installed or improperly   groundedequipment is a hazard.   D Turn Off inverter, disconnect input power, and discharge input   capacitors according to instructions in Maintenance Section   before touching any parts.   D D D Do not touch live electrical parts.   Wear dry, hole-free insulating gloves and body protection.   FUMES AND GASES can be hazardous.   Insulate yourself from work and ground using dry insulating mats   or covers big enough to prevent any physical contact with the work   or ground.   Welding produces fumes and gases. Breathing   these fumes and gases can be hazardous to your   health.   D Do not use AC output in damp areas, if movement is confined, or if   there is a danger of falling.   D D Keep your head out of the fumes. Do not breathe the fumes.   D D Use AC output ONLY if required for the welding process.   If inside, ventilate the area and/or use exhaust at the arc to remove   welding fumes and gases.   If AC output is required, use remote output control if present on   unit.   D D If ventilation is poor, use an approved air-supplied respirator.   D Disconnect input power or stop engine before installing or   servicing this equipment. Lockout/tagout input power according to   OSHA 29 CFR 1910.147 (see Safety Standards).   Read the Material Safety Data Sheets (MSDSs) and the   manufacturer’s instructions for metals, consumables, coatings,   cleaners, and degreasers.   D D Properly install and ground this equipment according to its   Owner’s Manual and national, state, and local codes.   D Work in a confined space only if it is well ventilated, or while   wearing an air-supplied respirator. Always have a trained watch-   person nearby. Welding fumes and gases can displace air and   lower the oxygen level causing injury or death. Be sure the breath-   ing air is safe.   Always verify the supply ground − check and be sure that input   power cord ground wire is properly connected to ground terminal in   disconnect box or that cord plug is connected to a properly   groundedreceptacle outlet.   D D Do not weld in locations near degreasing, cleaning, or spraying op-   erations. The heat and rays of the arc can react with vapors to form   highly toxic and irritating gases.   D D When making input connections, attach proper grounding conduc-   tor first − double-check connections.   Frequently inspect input power cord for damage or bare wiring −   replace cord immediately if damaged − bare wiring can kill.   Do not weld on coated metals, such as galvanized, lead, or   cadmiumplated steel, unless the coating is removed from the weld   area, the area is well ventilated, and if necessary, while wearing an   air-suppliedrespirator. The coatings and any metals containing   these elements can give off toxic fumes if welded.   D D D Turn off all equipment when not in use.   Do not use worn, damaged, undersized, or poorly spliced cables.   Do not drape cables over your body.   OM-186 895 Page 1   Download from Www.Somanuals.com. All Manuals Search And Download.   ARC RAYS can burn eyes and skin.   BUILDUP OF GAS can injure or kill.   D D Shut off shielding gas supply when not in use.   Always ventilate confined spaces or use   approved air-supplied respirator.   Arc rays from the welding process produce intense   visible and invisible (ultraviolet and infrared) rays   that can burn eyes and skin. Sparks fly off from the   weld.   D Wear a welding helmet fitted with a proper shade of filter to protect   your face and eyes when welding or watching (see ANSI Z49.1   and Z87.1 listed in Safety Standards).   HOT PARTS can cause severe burns.   D D D Wear approved safety glasses with side shields under your   helmet.   D D Do not touch hot parts bare handed.   Allow cooling period before working on gun or   torch.   Use protective screens or barriers to protect others from flash and   glare; warn others not to watch the arc.   Wear protective clothing made from durable, flame-resistant mate-   rial (leather and wool) and foot protection.   MAGNETIC FIELDS can affect pacemakers.   WELDING can cause fire or explosion.   D D Pacemaker wearers keep away.   Wearers should consult their doctor before   going near arc welding, gouging, or spot   welding operations.   Welding on closed containers, such as tanks,   drums, or pipes, can cause them to blow up. Sparks   can fly off from the welding arc. The flying sparks, hot   workpiece, and hot equipment can cause fires and   burns. Accidental contact of electrode to metal objects can cause   sparks, explosion, overheating, or fire. Check and be sure the area is   safe before doing any welding.   NOISE can damage hearing.   D D D Protect yourself and others from flying sparks and hot metal.   Do not weld where flying sparks can strike flammable material.   Noise from some processes or equipment can   damagehearing.   Remove all flammables within 35 ft (10.7 m) of the welding arc. If   this is not possible, tightly cover them with approved covers.   D Wear approved ear protection if noise level is   high.   D Be alert that welding sparks and hot materials from welding can   easily go through small cracks and openings to adjacent areas.   D D Watch for fire, and keep a fire extinguisher nearby.   CYLINDERS can explode if damaged.   Be aware that welding on a ceiling, floor, bulkhead, or partition can   cause fire on the hidden side.   Shielding gas cylinders contain gas under high   pressure. If damaged, a cylinder can explode. Since   gas cylinders are normally part of the welding   process, be sure to treat them carefully.   D D Do not weld on closed containers such as tanks, drums, or pipes,   unless they are properly prepared according to AWS F4.1 (see   Safety Standards).   Connect work cable to the work as close to the welding area as   practical to prevent welding current from traveling long, possibly   unknown paths and causing electric shock and fire hazards.   D D Protect compressed gas cylinders from excessive heat, mechani-   cal shocks, slag, open flames, sparks, and arcs.   Install cylinders in an upright position by securing to a stationary   support or cylinder rack to prevent falling or tipping.   D D Do not use welder to thaw frozen pipes.   Remove stick electrode from holder or cut off welding wire at   contact tip when not in use.   D D D D D Keep cylinders away from any welding or other electrical circuits.   Never drape a welding torch over a gas cylinder.   D D Wear oil-free protective garments such as leather gloves, heavy   shirt, cuffless trousers, high shoes, and a cap.   Never allow a welding electrode to touch any cylinder.   Never weld on a pressurized cylinder − explosion will result.   Remove any combustibles, such as a butane lighter or matches,   from your person before doing any welding.   Use only correct shielding gas cylinders, regulators, hoses, and fit-   tings designed for the specific application; maintain them and   associated parts in good condition.   FLYING METAL can injure eyes.   D D Turn face away from valve outlet when opening cylinder valve.   D Welding, chipping, wire brushing, and grinding   cause sparks and flying metal. As welds cool,   they can throw off slag.   Keep protective cap in place over valve except when cylinder is in   use or connected for use.   D Read and follow instructions on compressed gas cylinders,   associated equipment, and CGA publication P-1 listed in Safety   Standards.   D Wear approved safety glasses with side   shields even under your welding helmet.   OM-186 895 Page 2   Download from Www.Somanuals.com. All Manuals Search And Download.   1-3. Additional Symbols For Installation, Operation, And Maintenance   FIRE OR EXPLOSION hazard.   MOVING PARTS can cause injury.   D Do not install or place unit on, over, or near   combustiblesurfaces.   Do not install unit near flammables.   D D Keep away from moving parts such as fans.   Keep all doors, panels, covers, and guards   closed and securely in place.   D D Do not overload building wiring − be sure power supply system is   properly sized, rated, and protected to handle this unit.   FALLING UNIT can cause injury.   H.F. RADIATION can cause interference.   D D D Use lifting eye to lift unit only, NOT running   gear, gas cylinders, or any other accessories.   Use equipment of adequate capacity to lift and   support unit.   If using lift forks to move unit, be sure forks are   long enough to extend beyond opposite side of   unit.   D High-frequency (H.F.) can interfere with radio   navigation, safety services, computers, and   communicationsequipment.   D Have only qualified persons familiar with   electronic equipment perform this installation.   D D The user is responsible for having a qualified electrician prompt-   ly correct any interference problem resulting from the installa-   tion.   If notified by the FCC about interference, stop using the   equipmentat once.   OVERUSE can cause OVERHEATING   D D Allow cooling period; follow rated duty cycle.   Reduce current or reduce duty cycle before   starting to weld again.   D D Have the installation regularly checked and maintained.   Keep high-frequency source doors and panels tightly shut, keep   spark gaps at correct setting, and use grounding and shielding to   minimize the possibility of interference.   D Do not block or filter airflow to unit.   STATIC (ESD) can damage PC boards.   D Put on grounded wrist strap BEFORE handling   boards or parts.   ARC WELDING can cause interference.   D Use proper static-proof bags and boxes to   store, move, or ship PC boards.   D Electromagnetic energy can interfere with   sensitive electronic equipment such as   computers and computer-driven equipment   such as robots.   MOVING PARTS can cause injury.   D Be sure all equipment in the welding area is   electromagneticallycompatible.   D D Keep away from moving parts.   Keep away from pinch points such as drive   rolls.   D D D D To reduce possible interference, keep weld cables as short as   possible, close together, and down low, such as on the floor.   Locate welding operation 100 meters from any sensitive elec-   tronic equipment.   WELDING WIRE can cause injury.   Be sure this welding machine is installed and grounded   according to this manual.   D Do not press gun trigger until instructed to do   so.   Do not point gun toward any part of the body,   other people, or any metal when threading   welding wire.   If interference still occurs, the user must take extra measures   such as moving the welding machine, using shielded cables,   using line filters, or shielding the work area.   D 1-4. Principal Safety Standards   Safety in Welding and Cutting, ANSI Standard Z49.1, from American   Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,   from Compressed Gas Association, 1235 Jefferson Davis Highway,   Suite 501, Arlington, VA 22202.   Code for Safety in Welding and Cutting, CSA Standard W117.2, from   Canadian Standards Association, Standards Sales, 178 Rexdale   Boulevard, Rexdale, Ontario, Canada M9W 1R3.   Safe Practices For Occupation And Educational Eye And Face   Protection, ANSI Standard Z87.1, from American National Standards   Institute, 1430 Broadway, New York, NY 10018.   Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126   Safety and Health Standards, OSHA 29 CFR 1910, from Superinten-   dent of Documents, U.S. Government Printing Office, Washington, D.C.   20402.   Recommended Safe Practices for the Preparation for Weldingand Cut-   ting of Containers That Have Held Hazardous Substances, American   Welding Society Standard AWS F4.1, from American Welding Society,   550 N.W. LeJeune Rd, Miami, FL 33126   NationalElectrical Code, NFPA Standard 70, from National Fire Protec-   tion Association, Batterymarch Park, Quincy, MA 02269.   Cutting And Welding Processes, NFPA Standard 51B, from National   Fire Protection Association, Batterymarch Park, Quincy, MA 02269.   OM-186 895 Page 3   Download from Www.Somanuals.com. All Manuals Search And Download.   1-5. EMF Information   Considerations About Welding And The Effects Of Low Frequency   Electric And Magnetic Fields   1. Keep cables close together by twisting or taping them.   2. Arrange cables to one side and away from the operator.   3. Do not coil or drape cables around your body.   Welding current, as it flows through welding cables, will cause electro-   magnetic fields. There has been and still is some concern about such   fields. However, after examining more than 500 studies spanning 17   years of research, a special blue ribbon committee of the National   Research Council concluded that: “The body of evidence, in the   committee’s judgment, has not demonstrated that exposure to power-   frequency electric and magnetic fields is a human-health hazard.”   However, studies are still going forth and evidence continues to be   examined.Until the final conclusions of the research are reached, you   may wish to minimize your exposure to electromagnetic fields when   welding or cutting.   4. Keep welding power source and cables as far away from opera-   tor as practical.   5. Connect work clamp to workpiece as close to the weld as possi-   ble.   About Pacemakers:   To reduce magnetic fields in the workplace, use the following   procedures:   Pacemaker wearers consult your doctor first. If cleared by your doctor,   then following the above procedures is recommended.   OM-186 895 Page 4   Download from Www.Somanuals.com. All Manuals Search And Download.   SECTION 1 − CONSIGNES DE SECURITE − LIRE AVANT   UTILISATION   som _nd_fre 5/97   1-1. Signification des symboles   SignifieMise en garde ! Soyez vigilant ! Cette procédure   présente des risques de danger ! Ceux-ci sont identifiés   par des symboles adjacents aux directives.   Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des   risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN   MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles   et aux directives ci-dessous afin de connaître les mesures à prendre pour   éviter tout danger.   Y Identifie un message de sécurité particulier.   . Signifie NOTA ; n’est pas relatif à la sécurité.   1-2. Dangers relatifs au soudage à l’arc   Y Les symboles présentés ci-après sont utilisés tout au long du   présent manuel pour attirer votre attention et identifier les risques   de danger. Lorsque vous voyez un symbole, soyez vigilant et   suivez les directives mentionnées afin d’éviter tout danger. Les   consignes de sécurité présentées ci-après ne font que résumer   l’information contenue dans les normes de sécurité énumérées   sécurité.   D D Ne pas toucher l’électrode quand on est en contact avec la pièce, la   terre ou une électrode provenant d’une autre machine.   N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-le-   champ les pièces endommagées. Entretenir l’appareil conformément   à ce manuel.   D D D Porter un harnais de sécurité quand on travaille en hauteur.   Maintenir solidement en place tous les panneaux et capots.   Y Y L’installation, l’utilisation, l’entretien et les réparations ne doi-   vent être confiés qu’à des personnes qualifiées.   Fixer le câble de retour de façon à obtenir un bon contact métal-métal   avec la pièce à souder ou la table de travail, le plus près possible de la   soudure.   Au cours de l’utilisation, tenir toute personne à l’écart et plus par-   ticulièrement les enfants.   D Isoler la pince de masse quand pas mis à la pièce pour éviter le contact   avec tout objet métallique.   UN CHOC ÉLECTRIQUE peut tuer.   Un simple contact avec des pièces électriques peut   provoquer une électrocution ou des blessures graves.   L’électrode et le circuit de soudage sont sous tension   dès que l’appareil est sur ON. Le circuit d’entrée et les   circuits internes de l’appareil sont également sous   Il y a DU COURANT CONTINU IMPORTANT dans les   convertisseurs après la suppression de l’alimenta-   tion électrique.   D Arrêter les convertisseurs, débrancher le courant électrique, et dé-   charger les condensateurs d’alimentation selon les instructions   indiquées dans la partie entretien avant de toucher les pièces.   tension à ce moment-là. En soudage semi-automatique ou automatique,   le fil, le dévidoir, le logement des galets d’entraînement et les pièces   métalliques en contact avec le fil de soudage sont sous tension. Des   matériels mal installés ou mal mis à la terre présentent un danger.   D D Ne jamais toucher les pièces électriques sous tension.   Porter des gants et des vêtements de protection secs ne comportant   pas de trous.   LES FUMÉES ET LES GAZ peuvent   être dangereux.   D S’isoler de la pièce et de la terre au moyen de tapis ou d’autres   moyens isolants suffisamment grands pour empêcher le contact phy-   sique éventuel avec la pièce ou la terre.   Ne pas se servir de source électrique àcourant électrique dans les zones   humides, dans les endroits confinés ou là où on risque de tomber.   Se servir d’une source électrique àcourant électrique UNIQUEMENT si le   procédé de soudage le demande.   Si l’utilisation d’une source électrique àcourant électrique s’avère néces-   saire, se servir de la fonction de télécommande si l’appareil en est équipé.   Couper l’alimentation ou arrêter le moteur avant de procéder à l’instal-   lation, à la réparation ou à l’entretien de l’appareil. Déverrouiller   l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de   sécurité).   Installer et mettre à la terre correctement cet appareil conformément à   son manuel d’utilisation et aux codes nationaux, provinciaux et   municipaux.   Toujours vérifier la terre du cordon d’alimentation − Vérifier et s’assu-   rer que le fil de terre du cordon d’alimentation est bien raccordé à la   borne de terre du sectionneur ou que la fiche du cordon est raccordée   à une prise correctement mise à la terre.   En effectuant les raccordements d’entrée fixer d’abord le conducteur   de mise à la terre approprié et contre-vérifier les connexions.   Le soudage génère des fumées et des gaz. Leur   inhalation peut être dangereux pour votre santé.   D D D D D Eloigner votre tête des fumées. Ne pas respirer   les fumées.   D A l’intérieur, ventiler la zone et/ou utiliser un échappement au niveau   de l’arc pour l’évacuation des fumées et des gaz de soudage.   D D Si la ventilation est insuffisante, utiliser un respirateur à alimenta-   tion d’air homologué.   Lire les spécifications de sécurité des matériaux (MSDSs) et les   instructions du fabricant concernant les métaux, les consomma-   bles, les revêtements, les nettoyants et les dégraisseurs.   Travailler dans un espace fermé seulement s’il est bien ventilé ou en   portant un respirateur à alimentation d’air. Demander toujours à un   surveillant dûment formé de se tenir à proximité. Des fumées et des   gaz de soudage peuvent déplacer l’air et abaisser le niveau d’oxy-   gène provoquant des blessures ou des accidents mortels. S’assu-   rer que l’air de respiration ne présente aucun danger.   Ne pas souder dans des endroits situés à proximité d’opérations de   dégraissage, de nettoyage ou de pulvérisation. La chaleur et les   rayons de l’arc peuvent réagir en présence de vapeurs et former des   gaz hautement toxiques et irritants.   D D D D D D D Vérifier fréquemment le cordon d’alimentation pour voir s’il n’est pas   endommagé ou dénudé − remplacer le cordon immédiatement s’il est   endommagé − un câble dénudé peut provoquer une électrocution.   Mettre l’appareil hors tension quand on ne l’utilise pas.   Ne pas utiliser des câbles usés, endommagés, de grosseur insuffi-   sante ou mal épissés.   Ne pas souder des métaux munis d’un revêtement, tels que l’acier   galvanisé, plaqué en plomb ou au cadmium à moins que le revête-   ment n’ait été enlevé dans la zone de soudure, que l’endroit soit bien   ventilé, et si nécessaire, en portant un respirateur à alimentation   d’air. Les revêtements et tous les métaux renfermant ces éléments   peuvent dégager des fumées toxiques en cas de soudage.   D D D D Ne pas enrouler les câbles autour du corps.   Si la pièce soudée doit être mise à la terre, le faire directement avec un   câble distinct − ne pas utiliser le connecteur de pièce ou le câble de   retour.   OM-186 895 Page 5   Download from Www.Somanuals.com. All Manuals Search And Download.   LES RAYONS DE L’ARC peuvent pro-   voquer des brûlures dans les yeux et   sur la peau.   LES ACCUMULATIONS DE GAZ ris-   quent de provoquer des blessures ou   même la mort.   Le rayonnement de l’arc du procédé de soudage   génère des rayons visibles et invisibles intenses   (ultraviolets et infrarouges) susceptibles de provoquer   des brûlures dans les yeux et sur la peau. Des étincelles sont projetées   pendant le soudage.   D Fermer l’alimentation du gaz protecteur en cas de   non utilisation.   D Veiller toujours à bien aérer les espaces confinés ou se servir d’un respi-   rateur d’adduction d’air homologué.   D Porter un casque de soudage muni d’un écran de filtre approprié pour   protéger votre visage et vos yeux pendant le soudage ou pour regar-   der (voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).   DES PIÈCES CHAUDES peuvent pro-   voquer des brûlures graves.   D D Porter des protections approuvés pour les oreilles si le niveau sondre est   trop élevé.   Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair   et de l’éblouissement; demander aux autres personnes de ne pas re-   garder l’arc.   D D Ne pas toucher des parties chaudes à mains nues   Prévoir une période de refroidissement avant   d’utiliser le pistolet ou la torche.   D Porter des vêtements de protection constitué dans une matière dura-   ble, résistant au feu (cuir ou laine) et une protection des pieds.   LE SOUDAGE peut provoquer un   incendie ou une explosion.   LES CHAMPS MAGNÉTIQUES peuvent   affecter les stimulateurs cardiaques.   Le soudage effectué sur des conteneurs fermés tels   que des réservoirs, tambours ou des conduites peut   provoquer leur éclatement. Des étincelles peuvent être   projetées de l’arc de soudure. La projection d’étincel-   D D Porteurs de stimulateur cardiaque, restez à distance.   Les porteurs d’un stimulateur cardiaque doivent   d’abord consulter leur médecin avant de s’approcher   des opérations de soudage à l’arc, de gougeage ou   de soudage par points.   les, des pièces chaudes et des équipements chauds peut provoquer des   incendies et des brûlures. Le contact accidentel de l’électrode avec des   objets métalliques peut provoquer des étincelles, une explosion, un   surchauffement ou un incendie. Avant de commencer le soudage, vérifier   et s’assurer que l’endroit ne présente pas de danger.   D D D Se protéger et d’autres personnes de la projection d’étincelles et de   métal chaud.   Ne pas souder dans un endroit là où des étincelles peuvent tomber sur   des substances inflammables.   Déplacer toutes les substances inflammables à une distance de 10,7   m de l’arc de soudage. En cas d’impossibilité les recouvrir soigneuse-   ment avec des protections homologués.   Des étincelles et des matériaux chauds du soudage peuvent facile-   ment passer dans d’autres zones en traversant de petites fissures et   des ouvertures.   LE BRUIT peut affecter l’ouïe.   Le bruit des processus et des équipements peut affecter   l’ouïe.   D Porter des protections approuvés pour les oreilles si   le niveau sondre est trop élevé.   D D D D Surveiller tout déclenchement d’incendie et tenir un extincteur à proxi-   mité.   Si des BOUTEILLES sont endomma-   gées, elles pourront exploser.   Le soudage effectué sur un plafond, plancher, paroi ou séparation   peut déclencher un incendie de l’autre côté.   Ne pas effectuer le soudage sur des conteneurs fermés tels que des   réservoirs, tambours, ou conduites, à moins qu’ils n’aient été prépa-   rés correctement conformément à AWS F4.1 (voir les normes de   sécurité).   Brancher le câble sur la pièce le plus près possible de la zone de sou-   dage pour éviter le transport du courant sur une longue distance par   des chemins inconnus éventuels en provoquant des risques d’élec-   trocution et d’incendie.   Des bouteilles de gaz protecteur contiennent du gaz   sous haute pression. Si une bouteille est endomma-   gée, elle peut exploser. Du fait que les bouteilles de gaz   font normalement partie du procédé de soudage, les   manipuler avec précaution.   D D D D Protéger les bouteilles de gaz comprimé d’une chaleur excessive,   des chocs mécaniques, du laitier, des flammes ouvertes, des étin-   celles et des arcs.   Placer les bouteilles debout en les fixant dans un support stationnai-   re ou dans un porte-bouteilles pour les empêcher de tomber ou de   se renverser.   Tenir les bouteilles éloignées des circuits de soudage ou autres cir-   cuits électriques.   Ne jamais placer une torche de soudage sur une bouteille à gaz.   Une électrode de soudage ne doit jamais entrer en contact avec une   D D D Ne pas utiliser le poste de soudage pour dégeler des conduites ge-   lées.   En cas de non utilisation, enlever la baguette d’électrode du porte-   électrode ou couper le fil à la pointe de contact.   Porter des vêtements de protection dépourvus d’huile tels que des   gants en cuir, une chemise en matériau lourd, des pantalons sans re-   vers, des chaussures hautes et un couvre chef.   D D bouteille.   D Avant de souder, retirer toute substance combustible de vos poches   telles qu’un allumeur au butane ou des allumettes.   D D Ne jamais souder une bouteille pressurisée − risque d’explosion.   Utiliser seulement des bouteilles de gaz protecteur, régulateurs,   tuyaux et raccords convenables pour cette application spécifique;   les maintenir ainsi que les éléments associés en bon état.   Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la   bouteille.   Maintenir le chapeau de protection sur la soupape, sauf en cas d’uti-   lisation ou de branchement de la bouteille.   Lire et suivre les instructions concernant les bouteilles de gaz com-   primé, les équipements associés et les publications P-1 CGA énu-   mérées dans les normes de sécurité.   DES PARTICULES VOLANTES   peuvent blesser les yeux.   D D D D Le soudage, l’écaillement, le passage de la pièce   à la brosse en fil de fer, et le meulage génèrent   des étincelles et des particules métalliques vo-   lantes. Pendant la période de refroidissement des soudures, elles ris-   quent de projeter du laitier.   D Porter des lunettes de sécurité avec écrans latéraux ou un écran facial.   OM-186 895 Page 6   Download from Www.Somanuals.com. All Manuals Search And Download.   1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement   et la maintenance   Risque D’INCENDIE OU   D’EXPLOSION.   DES ORGANES MOBILES peuvent   provoquer des blessures.   D Ne pas placer l’appareil sur, au-dessus ou à proxi-   mité de surfaces infllammables.   D Rester à l’écart des organes mobiles comme le   ventilateur.   D Maintenir fermés et fixement en place les portes,   panneaux, recouvrements et dispositifs de   protection.   D D Ne pas installer l’appareil à proximité de produits inflammables   Ne pas surcharger l’installation électrique − s”assurer que l’alimen-   tation est correctement dimensionné et protégé avant de mettre   l’appareil en service.   LE RAYONNEMENT HAUTE FRÉ-   QUENCE (H.F.) risque de provoquer   des interférences.   LA CHUTE DE L’APPAREIL peut   blesser.   D Le rayonnement haute frequence peut provoquer   des interférences avec les équipements de ra-   dio−navigationet de communication, les services   de sécurité et les ordinateurs.   D Utiliser l’anneau de levage uniquement pour sou-   lever l’appareil, NON PAS les chariot, les bouteil-   les de gaz ou tout autre accessoire.   D Demander seulement à des personnes qualifiées familiarisées   avec des équipements électroniques de faire fonctionner l’installa-   tion.   L’utilisateur est tenu de faire corriger rapidement par un électricien   qualifié les interférences résultant de l’installation.   D Utiliser un engin d’une capacité appropriée pour   soulever l’appareil.   D En utilisant des fourches de levage pour déplacer l’unité, s’assurer   que les fourches sont suffisamment longues pour dépasser du côté   opposé de l’appareil.   D D Si le FCC signale des interférences, arrêter immédiatement l’appa-   reil.   L’EMPLOI EXCESSIF peut   D D Effectuer régulièrement le contrôle et l’entretien de l’installation.   Maintenir soigneusement fermés les portes et les panneaux des   sources de haute fréquence, maintenir les éclateurs à une distance   correcte et utiliser une terre et et un blindage pour réduire les interfé-   rences éventuelles.   SURCHAUFFER L’ÉQUIPEMENT.   D Prévoir une période de refroidissement, respec-   ter le cycle opératoire nominal.   D Réduire le courant ou le cycle opératoire avant de   recommancer le soudage.   LE SOUDAGE À L’ARC risque de   provoquer des interférences.   D Ne pas obstruer les passages d’air du poste.   LES CHARGES ÉLECTROSTATI-   QUES peuvent endommager les cir-   cuits imprimés.   D L’énergie électromagnétique risque de provoquer   des interférences pour l’équipement électronique   sensible tel que les ordinateurs et l’équipement   commandé par ordinateur tel que les robots.   D D Veiller à ce que tout l’équipement de la zone de soudage soit com-   D Établir la connexion avec la barrette de terre   avant de manipuler des cartes ou des pièces.   Utiliser des pochettes et des boîtes antistatiques   pour stocker, déplacer ou expédier des cartes de   circuits imprimes.   patible électromagnétiquement.   Pour réduire la possibilité d’interférence, maintenir les câbles de   soudage aussi courts que possible, les grouper, et les poser aussi   bas que possible (ex. par terre).   Veiller à souder à une distance de 100 mètres de tout équipement   électronique sensible.   Veiller à ce que ce poste de soudage soit posé et mis à la terre   conformément à ce mode d’emploi.   En cas d’interférences après avoir pris les mesures précédentes, il   incombe à l’utilisateur de prendre des mesures supplémentaires tel-   les que le déplacement du poste, l’utilisation de câbles blindés, l’uti-   lisation de filtres de ligne ou la pose de protecteurs dans la zone de   travail.   D D D D DES ORGANES MOBILES peuvent   provoquer des blessures.   D D Ne pas s’approcher des organes mobiles.   Ne pas s’approcher des points de coincement   tels que des rouleaux de commande.   LES CHAMPS MAGNÉTIQUES peuvent   affecter les stimulateurs cardiaques.   LES FILS DE SOUDAGE peuvent pro-   voquer des blessures.   D D Porteurs de stimulateur cardiaque, restez à dis-   tance.   Les porteurs d’un stimulateur cardiaque doivent   d’abord consulter leur médecin avant de s’appro-   cher des opérations de soudage à l’arc, de gou-   geage ou de soudage par points.   D Ne pas appuyer sur la gachette avant d’en avoir   reçu l’instruction.   Ne pas diriger le pistolet vers soi, d’autres person-   nes ou toute pièce mécanique en engageant le fil   de soudage.   D OM-186 895 Page 7   Download from Www.Somanuals.com. All Manuals Search And Download.   1-4. Principales normes de sécurité   Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Wel-   Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,   de la Compressed Gas Association, 1235 Jefferson Davis Highway,   Suite 501, Arlington, VA 22202.   ding Society, 550 N.W. Lejeune Rd, Miami FL 33126   Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent   of Documents, U.S. Government Printing Office, Washington, D.C.   20402.   Règles de sécurité en soudage, coupage et procédés connexes, norme   CSA W117.2, de l’Association canadienne de normalisation, vente de   normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.   RecommendedSafe Practice for the Preparation for Welding and Cut-   ting of Containers That Have Held Hazardous Substances, norme AWS   F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL   33126   Safe Practices For Occupation And Educational Eye And Face Protec-   tion, norme ANSI Z87.1, de l’American National Standards Institute,   1430 Broadway, New York, NY 10018.   NationalElectrical Code, NFPA Standard 70, de la National Fire Protec-   tion Association, Batterymarch Park, Quincy, MA 02269.   Cutting and Welding Processes, norme NFPA 51B, de la National Fire   Protection Association, Batterymarch Park, Quincy, MA 02269.   1-5. Information sur les champs électromagnétiques   Données sur le soudage électrique et sur les effets, pour l’organisme,   des champs magnétiques basse fréquence   Afin de réduire les champs électromagnétiques dans l’environnement   de travail, respecter les consignes suivantes :   1 Garder les câbles ensembles en les torsadant ou en les   attachant avec du ruban adhésif.   Le courant de soudage, pendant son passage dans les câbles de sou-   dage, causera des champs électromagnétiques. Il y a eu et il y a encore   un certain souci à propos de tels champs. Cependant, après avoir ex-   aminé plus de 500 études qui ont été faites pendant une période de   recherche de 17 ans, un comité spécial ruban bleu du National Re-   search Council a conclu: “L’accumulation de preuves, suivant le   jugement du comité, n’a pas démontré que l’exposition aux champs   magnétiqueset champs électriques à haute fréquence représente un   risque à la santé humaine”. Toutefois, des études sont toujours en cours   et les preuves continuent à être examinées. En attendant que les con-   clusions finales de la recherche soient établies, il vous serait   souhaitablede réduire votre exposition aux champs électromagnéti-   ques pendant le soudage ou le coupage.   2 3 Mettre tous les câbles du côté opposé de l’opérateur.   Ne pas courber pas et ne pas entourer pas les câbles autour de   votre corps.   4 5 Garder le poste de soudage et les câbles le plus loin possible de   vous.   Relier la pince de masse le plus près possible de la zone de   soudure.   Consignes relatives aux stimulateurs cardiaques :   Les personnes qui portent un stimulateur cardiaque doivent avant tout   consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est   alors recommandé de respecter les consignes ci−dessus.   OM-186 895 Page 8   Download from Www.Somanuals.com. All Manuals Search And Download.   SECTION 2 − DEFINITIONS   2-1. Warning Label Definitions   A. Warning! Watch Out! There   are possible hazards as   shown by the symbols.   B. Drive rolls can injure fingers.   A B C C. Welding wire and drive parts   are at welding voltage during   operation − keep hands and   metal objects clear.   1 Electric shock can kill.   1.1 Wear dry insulating gloves.   Do not touch electrode with   bare hand. Do not wear wet or   damaged gloves.   1.2 Protect yourself from electric   shock by insulating yourself   from work and ground.   1 2 1.1   2.1   3.1   4.1   1.2   1.3   1.3 Disconnect input plug or   power before working on   machine.   2 Breathing welding fumes can   be hazardous to your health.   2.2   2.3   2.1 Keep your head out of the   fumes.   2.2 Use forced ventilation or local   exhaust to remove the fumes.   2.3 Use ventilating fan to remove   fumes.   3 4 5 3.2   3.3   3 Welding sparks can cause   explosion or fire.   3.1 Keep flammables away from   welding. Don’t weld near   flammables.   3.2 Welding sparks can cause   fires. Have a fire extinguisher   nearby and have a watch   person ready to use it.   + + +   3.3 Do not weld on drums or any   closed containers.   4 Arc rays can burn eyes and   injure skin.   6 4.1 Wear hat and safety glasses.   Use ear protection and button   shirt collar. Use welding   helmet with correct shade of   filter. Wear complete body   protection.   + S-178 936   5 Become trained and read the   instructions before working on   the machine or welding.   6 Do not remove or paint over   (cover) the label.   OM-186 895 Page 9   Download from Www.Somanuals.com. All Manuals Search And Download.   2-2. Rating Label For CE Products   S/N:   U1   I =   1 50/60 Hz   IP 23   24 V   1 = 7.0   A U2   = I =   500 A   2 100 V   X 100 %   178 794-A   2-3. Symbols And Definitions   Some symbols are found only on CE products.   NOTE   On   Off   Input   Output   Amperes   Volts   Hertz   AlternatingCurrent   Circuit Breaker   Duty Cycle   Wire Feed   A IP   V Hz   U1   X Degree Of   Protection   Gas Metal Arc   Welding (GMAW)   Gun   Jog   Primary Voltage   Spot Weld Time   Line Connection   Continuous Weld   Purge   Spot Weld   Burnback Time   Load Voltage   Preflow Time   Postflow Time   Rated Current   Read Instructions   Primary Voltage   Primary Current   U2   I1   I2   U1   OM-186 895 Page 10   Download from Www.Somanuals.com. All Manuals Search And Download.   SECTION 3 − INSTALLATION   3-1. Specifications   Welding   Type of Input   Power   Wire   Diameter   Range   Welding   Circuit   Rating   Wire Feed   Speed Range   IP   Rating   Overall   Dimensions   Weight   Power   Source Type   Length: 597 mm   (23-1/2 in)   0.6 To 2 mm   100 Volts,   500 Amperes,   100%   Constant Voltage   (.023 To 5/64 in)   24 Volts AC   (CV) DC With   Single Phase   14-Pin And   7 Amperes 50/60   Contactor   1.9 To 19 mpm   (75 to 750 ipm)   Width: 273 mm   (10-3/4 in)   IP 23   15.9 kg (35 lb)   Max Spool   Weight:   27 kg (60 lb)   Duty Cycle   Hz   Height: 279 mm   (11 in)   Control   3-2. Site Selection   1 Wire Feeder   Lifting Eye   Rubber Feet   Slot   2 3 4 5 6 1 Choose slot that allows all rubber   feet to sit securely on top of welding   power source.   7 5 6 Wire Spool/Reel   Gas Cylinder (Customer   Supplied)   7 Welding Power Source   Y Do not put feeder where   welding wire hits cylinder.   Y Do not move or operate   equipment when it could tip.   8 Lifting Handle   Y Manuallyuse handle to move   or briefly lift feeder.   Y Do not use lifting hook or   other devices to lift or   suspend feeder by the   handle.   2 4 3 8 801 920-C / Ref. 152 468-A / 155 242 / 801 919-C / 188 674   OM-186 895 Page 11   Download from Www.Somanuals.com. All Manuals Search And Download.   3-3. Gun Recommendation Table   Process   Gun   GMAW − Hard or Corded Wires   FCAW − Self-Shielding Wires   M25 Or M40   GA-40GL   3-4. Equipment Connection Diagrams   1 2 3 CV Welding Power Source   With 24 VAC Power   CV Welding Power Source   Without 24 VAC Power   115 Volts AC /24 Volts AC   Power Adapter   4 5 6 14-Pin Control Cord   Weld Cable (Required)   Work   1 4 6 3 5 2 115VAC   4 Contactor   6 5 3-5. 14-Pin Receptacle, Shielding Gas And Optional Volt Sense Lead   1 Gas Hose With 5/8-18 Right-   hand Thread Fittings (Cus-   tomer Supplied)   3 2 14 Pin Receptacle RC9   2 Use interconnecting cord to make   connection to welding power   source.   3 Power Switch   1 Tools Needed:   5/8, 11/16 in   801 921-C   OM-186 895 Page 12   Download from Www.Somanuals.com. All Manuals Search And Download.   3-6. 14-Pin Receptacle Information   Pin*   Pin Information   A B G C D E F 24 volts ac with respect to pin G.   Contact closure to A completes 24 volts ac contactor control circuit.   Circuit common for 24 volts AC circuit.   J A E K I B N L C +10 volts dc output to remote control with respect to pin D.   Remote control circuit common.   H M F D G 0 to +10 volts dc input command signal from remote control with respect to pin D.   Current feedback; 0 to 10 volts dc, 1 V/100 A   H Voltage feedback; 0 to 10 volts dc, 1 V/10 arc volts   *The remaining pins are not used.   Ref. S-0004-A   3-7. Connecting Welding Gun And Weld Cable   1 2 Gun/FeederAdapter   Gun Connector   Insert gun connector into adapter.   Tighten locking ring.   3 4 Weld Cable Terminal   Weld Cable From Welding   Power Source   1 2 4 3 Tools Needed:   9/16, 5/8 in   801 922-B   OM-186 895 Page 13   Download from Www.Somanuals.com. All Manuals Search And Download.   3-8. Optional Meter Circuit Board Settings   1 2 3 4 Meter Circuit Board   DIP Switch S2   Potentiometer R18   Receptacle RC16   Wiring harness with free-hanging   plug PLG42 connects to RC16.   For voltage feedback from voltage   sensing lead, connect plug PLG43   from unit wiring harness to PLG42.   For voltage feedback from welding   power source to wire feeder 14-pin   receptacle, connect plug PLG41   from unit wiring harness to PLG42.   1 2 1 2 X Means switch position does not affect   specified function.   . Means switch must be in this position.   Voltage Sensing Function   Digital Meter Display   Arc Voltage Sensing Using Voltage Sensing   Lead For Welding Power Source That Does   Not Support Pins F And H   Meters/Minute   1 2 3 4 5 1 2 3 4 5 Or   Or   Inches/Minute   Arc Voltage Sensing Using Feedback From   Welding Power Source That Does Support   Pins F And H   1 2 3 4 5 1 2 3 4 5 Tools Needed:   1/4 in   801 925-C / Ref. 186 266   OM-186 895 Page 14   Download from Www.Somanuals.com. All Manuals Search And Download.   3-9. Motor Start/Burnback Control   To change wire feed starting speed   proceed as follows:   Turn Off unit and welding power   source.   1 Remove wrapper.   1 2 Motor Board PC1   Motor Start Control   Potentiometer R73   Remove protective white rubber   cap before making adjustment.   Adjust potentiometer R73 using a   small nonconductive screwdriver.   Rotate potentiometer clockwise to   increase time it takes the motor to   ramp up to speed.   3 Burnback Potentiometer R42   Remove protective white rubber   cap before making adjustment.   Adjust potentiometer R42 using a   small nonconductive screwdriver.   Rotate potentiometer clockwise to   increase burnback time.   2 Reinstall wrapper.   3 Tools Needed:   Non-Conductive   1/4 in   801 925-C / 192 653   OM-186 895 Page 15   Download from Www.Somanuals.com. All Manuals Search And Download.   3-10. Installing Wire Guide And Drive Roll   Install and secure inlet wire guide   on either assembly, and   intermediatewire guide on 4 drive   roll assembly only. Install drive rolls   and turn drive roll nut one click.   During maintenance intervals,   remove drive rolls, and clean   grooves using a wire brush. Check   groove of drive roll for pitting or   increase in the depth of the groove   indicating drive roll is worn out.   Tools Needed:   3/8 in   801 923-C   OM-186 895 Page 16   Download from Www.Somanuals.com. All Manuals Search And Download.   3-11. Installing And Threading Welding Wire   1 2 Retaining Ring   Hub Tension Adjustment Nut   If necessary, move hub on support   for use of different size wire spool.   Remove retaining ring, and install   spool so hub pin fits spool hole.   Reinstall retaining ring.   1 2 3 Adjust tension nut so wire is taut   when wire feed stops.   3 Pressure Assembly   Adjustment Knob   Lay gun cable out straight.   A Open pressure assembly,   hold wire tightly, and cut off   end. Push wire through guides   into gun.   B C Close and tighten pressure   assembly. Press JOG button   until wire comes out gun.   To adjust drive roll pressure,   press gun trigger to feed wire   against wood surface. Tighten   knob so wire does not slip.   Cut off wire. Close door.   A B C Tighten   WOOD   Tools Needed:   15/16 in   Ref. 801 924-B / S-0627-A   OM-186 895 Page 17   Download from Www.Somanuals.com. All Manuals Search And Download.   SECTION 4 − OPERATION   4-1. Front Panel Controls   1 2 Optional Voltage/Wire Speed   Meter   1 Optional Voltage/Wire Speed   Switch   Use to choose volts or wire feed   speed display.   2 3 3 Optional Remote Voltage   Control   Use to set welding power source   voltage at the wire feeder. Numbers   are for reference only.   4 5 Wire Speed Control   Jog/Purge Switch   4 Use Jog position to momentarily   feed welding wire at speed set on   Wire Speed control without ener-   gizing welding circuit or shielding   gas valve.   Use Purge position to momentarily   energizegas valve to purge air from   gun or adjust gas regulator.   5 6 Trigger Hold Switch   Push up to weld without holding gun   trigger throughout the weld cycle.   To start weld cycle, press and re-   lease gun trigger within three se-   conds after an arc has been struck.   To end weld, press and release gun   trigger.   Power switch is on rear panel (see   6 Ref. 188 340-A   OM-186 895 Page 18   Download from Www.Somanuals.com. All Manuals Search And Download.   4-2. Optional Side Panel Controls   1 Preflow Control   Control sets time gas flows before   welding wire is energized. Time   range is 0 to 5 seconds.   1 2 Postflow Control   Control sets time gas flows after   completion of burnback. Time   range is 0 to 5 seconds.   3 Spot Time Control   2 Factory set for 0.25 to 5 seconds of   spot time. Rotating knob fully   counterclockwise   selects   an   untimed continuous weld.   Close side door.   3 Ref. 801 923-C / Ref. 186 589   SECTION 5 − MAINTENANCE & TROUBLESHOOTING   5-1. Routine Maintenance   Y Disconnect power before maintaining.   3 Months   Repair Or   Replace   Cracked   Clean And   Tighten   Weld   Replace   Unreadable   Labels   Weld Cable   Terminals   Replace   Cracked   Parts   14-Pin Cord   Gun Cable   Gas Hose   6 Months   Blow Out Or Vacuum   Clean   Drive   Rolls   Inside,   OR   During Heavy Service,   Clean Monthly   OM-186 895 Page 19   Download from Www.Somanuals.com. All Manuals Search And Download.   5-2. Overload Protection   Y Turn Off wire feeder and   welding power source. Stop   engine   on   welding   1 generator.   1 Circuit Breaker CB1   CB1 protects wire feeder from over-   load.   Correct problem and manually   reset breaker.   801 921-C   5-3. Troubleshooting   Trouble   Remedy   Wire does not feed, unit completely inop- Turn Power switch On.   erative.   Check 14−pin receptacle RC9 connections.   Check input power.   Wire does not feed.   Check gun trigger connection at wire feeder. Check gun trigger leads and trigger switch. See gun Owner’s   Manual.   Have Factory Authorized Service Agent check drive motor and control board PC1.   Use correct size drive roll (see Parts List).   Wire feeds erratically.   Remove weld spatter around nozzle opening.   Replace contact tip or liner. See gun Owner’s Manual.   Have Factory Authorized Service Agent check drive motor and control board PC1.   Wire feeds when Jog switch is pressed Check gun trigger connection at wire feeder. Check gun trigger leads and trigger switch. See gun Owner’s   but not when gun trigger is pressed. Manual.   Wire feeds as soon as power is applied. Check gun trigger. See gun Owner’s Manual.   Wire does not feed until trigger is Check for short between gun trigger leads and weld cable. Repair or replace gun trigger leads.   pressed but continues to feed after trig-   ger is released.   Gas valve rattles loudly and wire feeds Check for short between gun trigger leads and weld cable. Repair or replace gun trigger leads.   slowly or erratically.   Gas does not flow; wire feeds.   OM-186 895 Page 20   Check gas valve and flowmeter.   Download from Www.Somanuals.com. All Manuals Search And Download.   SECTION 6 − ELECTRICAL DIAGRAM   186 738-B   Figure 6-1. Circuit Diagram For Wire Feeder With Optional Equipment   OM-186 895 Page 21   Download from Www.Somanuals.com. All Manuals Search And Download.   SECTION 7 − PARTS LIST   7 8 6 9 10   11   12   3 13   2 12   11   1 5 14   4 15   16   21   50   23   22   49   24   17   20   48   19   18   51   53   52   25   26   47   27   28   46   29   30   45   32   33   34   35   39   40   31   41   36   42   37   43   23   38   44   . Hardware is common and   801 990-C   not available unless listed.   Figure 7-1. Main Assembly   OM-186 895 Page 22   Download from Www.Somanuals.com. All Manuals Search And Download.   Item   No.   Dia.   Mkgs.   Part   No.   Description   Figure 7-1. Main Assembly   Quantity   . . . 1 . . . . . . . . . . . . . 089 899 . . . LATCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 2 . . . . . . . . . . . . +186 674 . . . WRAPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 3 . . . . . . . . . . . . . 178 936 . . . LABEL, warning electric shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 4 . . . . . . . . . . . . . 187 909 . . . HANDLE, lifting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . . . . . . . . . . . 604 423 . . . GRIP, handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 5 . . . . . . . . . . . . . 188 674 . . . LABEL, caution incorrect lifting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 6 . . . . . . . . . . . . . 072 094 . . . HUB & SPINDLE ASSEMBLY, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 7 . . . . . . . . . . . . . 058 427 . . . . RING, retaining spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 8 . . . . . . . . . . . . . 180 572 . . . . SHAFT, spool support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 9 . . . . . . . . . . . . . 010 233 . . . . SPRING, cprsn .970 OD x .120 wire x 1.250 . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 10 . . . . . . . . . . . . . 057 971 . . . . WASHER, flat stl keyed 1.500dia x .125thk . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 11 . . . . . . . . . . . . . 010 191 . . . . WASHER, fbr .656 ID x 1.500 OD x .125thk . . . . . . . . . . . . . . . . . . . . . . . . 2   . . . 12 . . . . . . . . . . . . . 058 628 . . . . WASHER, brake stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2   . . . 13 . . . . . . . . . . . . . 058 428 . . . . HUB, spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 14 . . . . . . . . . . . . . 135 205 . . . . NUT, stl slflkg hex reg .625-11 w/nylon insert . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 15 . . . . . . . . . . . . . 137 461 . . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 16 . . . . . . . . . . . . . 134 306 . . . FOOT, rbr 1.250dia x 1.375 high . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4   . . . 17 . . . . PC1 . . . . 192 652 . . . CIRCUIT CARD, motor speed control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . PLG1 . . . 115 093 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . PLG3 . . . 115 092 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . PLG4 . . . 115 091 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . PLG5 . . . 130 203 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 18 . . . . . . . . . . . . . 134 201 . . . STAND-OFF SUPPORT, PC card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5   . . . 19 . . . . . . . . . . . . . 131 181 . . . WIRE GUIDE & NUT (22A Model) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 20 . . . . PC3 . . ♦186 297 . . . CIRCUIT CARD, timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . . . . . . . . . ♦098 691 . . . STAND-OFF, No 6-32 x .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . PLG1 . ♦115 093 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . PLG3 . ♦135 409 . . . CONNECTOR & PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . PLG33 . ♦115 092 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . PLG51 . ♦115 091 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 21 . . . . . . . . . . . ♦176 518 . . . FITTING, pipe brs elb 1/4NPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2   . . . 22 . . . . . . . . . . . ♦188 408 . . . FITTING, barb flow switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2   . . . 23 . . . . . . . . . . . ♦188 442 . . . WASHER, shldr .515 ID 1.000 OD x .094thk . . . . . . . . . . . . . . . . . . . . . . . . . 8   . . . 24 . . . . . . . . . . . ♦163 603 . . . SWITCH, flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 25 . . . . . . . . . . . ♦601 881 . . . NUT, .500-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2   . . . 26 . . . . S1 . . . . . 111 997 . . . SWITCH, rocker SPST 10A 250VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 27 . . . . . . . . . . . . . 112 863 . . . FITTING, hose brs barbed M 1/4tbg x 5/8-18 SAE . . . . . . . . . . . . . . . . . . . . 1   . . . 28 . . . . . . . . . . . ♦126 693 . . . CABLE, sensing 15ft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 29 . . . . . . . . . . . . . 605 227 . . . NUT, nyl hex jam .750NPST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 30 . . . . CB1 . . . . 161 078 . . . CIRCUIT BREAKER, man reset 1P 7A 250VAC . . . . . . . . . . . . . . . . . . . . . . 1   . . . 31 . . . . M1 . . . . 193 188 . . . MOTOR, gear 24VDC 146RPM (consisting of) . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . . . . . . . . . . *136 745 . . . . BRUSH & SPRING ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2   . . . 32 . . . . GS1 . . . . 125 785 . . . VALVE, 24VAC 2 way custom port 1/8 orf . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 33 . . . . RC9 . . . . 152 492 . . . RECEPTACLE W/PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 34 . . . . R1 . . . . . 073 562 . . . POTENTIOMETER, C sltd sft1/T 2W 10K ohm . . . . . . . . . . . . . . . . . . . . . . 1   . . . 35 . . . . R50 . . ♦035 897 . . . POTENTIOMETER, C sltd sft1/T 2W 1K linear . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 36 . . . . S2 . . . . . 134 846 . . . SWITCH, tgl SPTT 6A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 37 . . . . S3 . . . . . 134 847 . . . SWITCH, tgl SPDT 15A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . . . . . . . . . . . 187 577 . . . COVER, opening meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . . . . . . . . . ♦133 644 . . . FRAME, snap-in switch rocker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 38 . . . . PC2 . . ♦186 268 . . . CIRCUIT CARD, meter (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . LCD1 . . . 181 355 . . . . METER, digital . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . PLG15 . ♦115 092 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . PLG16 . ♦131 055 . . . CONNECTOR & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . . . . . . . . . ♦115 443 . . . STAND-OFF, 6-32 x .750 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2   OM-186 895 Page 23   Download from Www.Somanuals.com. All Manuals Search And Download.   Item   No.   Dia.   Mkgs.   Part   No.   Description   Quantity   Figure 7-1. Main Assembly (Continued)   . . . 39 . . . . . . . . . . . . . 192 955 . . . CASE ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 40 . . . LED1 . ♦179 203 . . . LED, 5100 2.0V 20MA green . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 41 . . . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE (order by model and serial number) . . . . . . . . . . . . . . . . . . . . 1   . . . 42 . . . . . . . . . . . . . 097 924 . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 43 . . . . . . . . . . . ♦097 924 . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 44 . . . . . . . . . . . ♦162 736 . . . FITTING, pipe brs qdisc fem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2   . . . . . . . . . . . . . . . . . ♦082 367 . . . FITTING, brs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . . . . . . . . . ♦188 428 . . . HOSE, water 15.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . . . . . . . . . ♦188 429 . . . HOSE, water 25.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 45 . . . . . . . . . . . . . 187 246 . . . ADAPTER, gun/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 46 . . . . . . . . . . . . . 178 937 . . . LABEL, warning electric shock and pinch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 47 . . . . . . . . . . . . . 192 875 . . . PLATE, insulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 48 . . . . . . . . Fig 7-2 & 7-3 . . . WIRE DRIVE ASSEMBLIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 49 . . . . . . . . . . . . . 188 149 . . . GUIDE, wire inlet(consisting of) (4 drive roll) . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 50 . . . . . . . . . . . . . 082 050 . . . . LINER, monocoil inlet wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . . . . . . . . . . . 082 036 . . . . GUIDE, wire inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . . . . . . . . . . . 187 421 . . . TUBE, guide .030-.035 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . . . . . . . . . . . 187 422 . . . TUBE, guide .045-.062 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 51 . . . . . . . . . . . . . 010 291 . . . WASHER, flat .625 x 1.250 OD x .125thk nylafil (22A Model) . . . . . . . . . . 1   . . . . . . . . . . . . . . . . . ♦191 002 . . . KIT, gun connection (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . . . . . . . . RC2 . . . . 048 282 . . . . RECEPTACLE w/SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 52 . . . . . . . . . . . ♦093 551 . . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3   . . . 53 . . . . . . . . . . . ♦186 587 . . . PLATE, control timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   +When ordering a component originally displaying a precautionary label, the label should also be ordered.   ♦OPTIONAL   To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested   Replacement Parts. Model and serial number required when ordering parts from your local distributor.   OM-186 895 Page 24   Download from Www.Somanuals.com. All Manuals Search And Download.   Item   No.   Dia.   Mkgs.   Part   No.   Description   Quantity   . . . 1 . . . . . . . . . . . . . 602 009 . . . SCREW, .250-20 x 1.250 soc hd hex gr 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 2 . . . . . . . . . . . . . 172 075 . . . CARRIER, drive roll w/component 24 pitch . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 3 . . . . . . . . . . . . . 054 263 . . . SCREW, thumb stl .250-20 x .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 4 . . . . . . . . . . . . . 010 224 . . . PIN, spring CS .187 x 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 5 . . . . . . . . . . . . . 166 072 . . . SPACER, gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 6 . . . . . . . . . . . . . 089 562 . . . FASTENER, pinned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 7 . . . . . . . . . . . . . 085 244 . . . WASHER, cupped stl .328 ID x .812 OD x .125 . . . . . . . . . . . . . . . . . . . . . . 1   . . . 8 . . . . . . . . . . . . . 089 477 . . . SPRING, cprsn .770 OD x .105 wire x 1.225 . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 9 . . . . . . . . . . . . . 085 243 . . . KNOB, adjustment tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 10 . . . . . . . . . . . . . 166 071 . . . LEVER, mtg pressure gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 11 . . . . . . . . . . . . . 151 828 . . . PIN, cotter hair .054 x .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2   . . . 12 . . . . . . . . . . . . . 079 634 . . . PIN, hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 13 . . . . . . . . . . . . . 144 172 . . . FITTING, hose brs barbed m 3/16 tbg x .250-20 . . . . . . . . . . . . . . . . . . . . . . 1   . . . 14 . . . . . . . . . . . . . 172 391 . . . HOUSING, adapter gun/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 15 . . . . . . . . . . . . . 048 449 . . . WASHER, shldr nyl .363 OD x .194 ID x .703 . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 16 . . . . . . . . . . . . . 124 778 . . . KNOB, T 2.000 bar w/.312-18 x 1.000lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 17 . . . . . . . . . . . . . 605 308 . . . RING, rtng ext .500 shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 18 . . . . . . . . . . . . . 079 625 . . . WASHER, wave .500 ID x .750 OD x .015thk . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 19 . . . . . . . . . . . . . 121 271 . . . SCREW, .250-20 x .500 soc hd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 20 . . . . . . . . . . . . . 172 076 . . . CARRIER, drive roll w/components 24 pitch . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 21 . . . . . . . . . . . . . 092 865 . . . KEY, stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   9 8 7 10   12   11   6 5 4 3 2 1 13   14   21   20   15   19   16   17   18   802 019-A   Figure 7-2. Drive Assembly, Wire (2 Drive Roll )   To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested   Replacement Parts. Model and serial number required when ordering parts from your local distributor.   OM-186 895 Page 25   Download from Www.Somanuals.com. All Manuals Search And Download.   Item   No.   Dia.   Mkgs.   Part   No.   Description   Quantity   . . . 1 . . . . . . . . . . . . . 602 009 . . . SCREW, .250-20 x 1.250 soc hd hex gr 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . 4   . . . 2 . . . . . . . . . . . . . 172 075 . . . CARRIER, drive roll w/component 24 pitch . . . . . . . . . . . . . . . . . . . . . . . . . . 4   . . . 3 . . . . . . . . . . . . . 166 072 . . . SPACER, gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4   . . . 4 . . . . . . . . . . . . . 054 263 . . . SCREW, thumb stl .250-20 x .500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2   . . . 5 . . . . . . . . . . . . . 010 224 . . . PIN, spring CS .187 x 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2   . . . 6 . . . . . . . . . . . . . 089 562 . . . FASTENER, pinned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2   . . . 7 . . . . . . . . . . . . . 085 244 . . . WASHER, cupped stl .328 ID x .812 OD x .125 . . . . . . . . . . . . . . . . . . . . . . 2   . . . 8 . . . . . . . . . . . . . 089 477 . . . SPRING, cprsn .770 OD x .105 wire x 1.225 . . . . . . . . . . . . . . . . . . . . . . . . . 2   . . . 9 . . . . . . . . . . . . . 085 243 . . . KNOB, adjustment tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2   . . . 10 . . . . . . . . . . . . . 166 071 . . . LEVER, mtg pressure gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 11 . . . . . . . . . . . . . 079 634 . . . PIN, hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 12 . . . . . . . . . . . . . 151 828 . . . PIN, cotter hair .054 x .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2   . . . 13 . . . . . . . . . . . . . 166 338 . . . LEVER, mtg pressure gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 14 . . . . . . . . . . . . . 605 308 . . . RING, rtng ext .500 shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 15 . . . . . . . . . . . . . 187 325 . . . INSULATOR, drive assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 16 . . . . . . . . . . . . . 144 172 . . . FITTING, hose brs barbed m 3/16 tbg x .250-20 . . . . . . . . . . . . . . . . . . . . . . 1   . . . 17 . . . . . . . . . . . . . 166 337 . . . HOUSING, adapter gun/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 18 . . . . . . . . . . . . . 168 590 . . . BUSHING, insulating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2   . . . 19 . . . . . . . . . . . . . 072 010 . . . WASHER, shldr .316 ID x .812 OD x .187thk . . . . . . . . . . . . . . . . . . . . . . . . 2   . . . 20 . . . . . . . . . . . . . 124 778 . . . KNOB, T 2.000 bar w/.312-18 x 1.000lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 21 . . . . . . . . . . . . . 079 625 . . . WASHER, wave .500 ID x .750 OD x .015thk . . . . . . . . . . . . . . . . . . . . . . . . 2   . . . 22 . . . . . . . . . . . . . 092 865 . . . KEY, stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 23 . . . . . . . . . . . . . 172 077 . . . CARRIER, drive roll keyed 24 pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   . . . 24 . . . . . . . . . . . . . 121 271 . . . SCREW, .250-20 x .500 soc hd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1   12   11   10   13   9 14   8 7 6 5 15   4 3 16   2 1 21   24   23   20   22   19   18   17   802 018-A   Figure 7-3. Drive Assembly, Wire (4 Drive Roll )   To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested   Replacement Parts. Model and serial number required when ordering parts from your local distributor.   OM-186 895 Page 26   Download from Www.Somanuals.com. All Manuals Search And Download.   Table 7-1. Drive Roll And Wire Guide Kits (2 Drive Roll)   Base selection of drive rolls upon the following recommended usages:   1. V-Grooved rolls for hard wire.   2. U-Grooved rolls for soft and soft shelled cored wires.   3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).   4. V-Knurled rolls for hard shelled cored wires.   NOTE   5. Drive roll types may be mixed to suit particular requirements (example:   V-Knurled roll in combination with U-Grooved).   Wire Diameter   Drive Roll   Part No.   Inlet   Kit No.   Wire Guide   Fraction   .023/.025 in   .030 in   Decimal   .023/.025 in   .030 in   Metric   0.6 mm   0.8 mm   0.9 mm   Type   087 131   079 594   079 595   087 130   053 695   053 700   V-Grooved   V-Grooved   V-Grooved   056 192   056 192   056 192   .035 in   .035 in   .040 in   .045 in   .052 in   1/16 in   .040 in   .045 in   .052 in   .062 in   1.0 mm   1.2 mm   1.3 mm   1.6 mm   161 189   079 596   079 597   079 598   053 696   053 697   053 698   053 699   V-Grooved   V-Grooved   V-Grooved   V-Grooved   056 192   056 193   056 193   056 195   .035 in   .045 in   .052 in   .035 in   .045 in   .052 in   0.9 mm   1.2 mm   1.3 mm   044 749   079 599   079 600   072 000   053 701   053 702   U-Grooved   U-Grooved   U-Grooved   056 192   056 193   056 193   1/16 in   5/64 in   .062 in   .079 in   1.6 mm   2.0 mm   079 601   079 602   053 706   053 704   U-Grooved   U-Grooved   056 195   056 195   .035 in   .035 in   0.9 mm   079 606   132 958   V-Knurled   056 192   .045 in   .052 in   1/16 in   .045 in   .052 in   .062 in   1.2 mm   1.3 mm   1.6 mm   079 607   079 608   079 609   132 957   132 956   132 955   V-Knurled   V-Knurled   V-Knurled   056 193   056 193   056 195   .068-.072 in   5/64 in   .068-.072 in   .079 in   1.8 mm   2.0 mm   089 984   079 610   132 959   132 960   V-Knurled   V-Knurled   056 195   056 195   .045 in   .052 in   1/16 in   5/64 in   .045 in   .052 in   .062 in   .079 in   1.2 mm   1.3 mm   1.6 mm   2.0 mm   083 318   083 317   079 614   079 615   083 489   083 490   053 708   053 710   U-Cogged   U-Cogged   U-Cogged   U-Cogged   056 193   056 193   056 195   056 195   S-0157-C   OM-186 895 Page 27   Download from Www.Somanuals.com. All Manuals Search And Download.   Table 7-2. Drive Roll & Wire Guide Kits (4 Drive Roll)   Base selection of drive rolls upon the following recommended usages:   1. V-Grooved rolls for hard wire.   2. U-Grooved rolls for soft and soft shelled cored wires.   3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).   4. V-Knurled rolls for hard shelled cored wires.   NOTE   5. Drive roll types may be mixed to suit particular requirements (example:   V-Knurled roll in combination with U-Grooved).   Wire Diameter   Decimal   .023/.025 in .023/.025 in   Drive Roll   Wire Guide   Kit No.   Fraction   Metric   0.6 mm   0.8 mm   0.9 mm   Part No.   Type   Inlet   Intermediate   087 132   046 780   046 781   087 130   053 695   053 700   V-Grooved   V-Grooved   V-Grooved   056 192   056 192   056 192   056 206   .030 in   .035 in   .030 in   .035 in   056 206   056 206   .040 in   .045 in   .052 in   1/16 in   .040 in   .045 in   .052 in   .062 in   1.0 mm   1.2 mm   1.3 mm   1.6 mm   191 917   046 782   046 783   046 784   053 696   053 697   053 698   053 699   V-Grooved   V-Grooved   V-Grooved   V-Grooved   056 192   056 193   056 193   056 195   056 206   056 207   056 207   056 209   .035 in   .045 in   .052 in   .035 in   .045 in   .052 in   0.9 mm   1.2 mm   1.3 mm   044 750   046 785   046 786   072 000   053 701   053 702   U-Grooved   U-Grooved   U-Grooved   056 192   056 193   056 193   056 206   056 207   056 207   1/16 in   5/64 in   .062 in   .079 in   1.6 mm   2.0 mm   046 787   046 788   053 706   053 704   U-Grooved   U-Grooved   056 195   056 195   056 209   056 209   .035 in   .045 in   .052 in   1/16 in   .035 in   .045 in   .052 in   .062 in   0.9 mm   1.2 mm   1.3 mm   1.6 mm   046 792   046 793   046 794   046 795   132 958   132 957   132 956   132 955   V-Knurled   V-Knurled   V-Knurled   V-Knurled   056 192   056 193   056 193   056 195   056 206   056 207   056 207   056 209   .068-.072 in .068-.072 in 1.8 mm   089 985   046 796   132 959   132 960   V-Knurled   V-Knurled   056 195   056 195   056 209   056 209   5/64 in   .079 in   2.0 mm   .045 in   .052 in   1/16 in   5/64 in   .045 in   .052 in   .062 in   .079 in   1.2 mm   1.3 mm   1.6 mm   2.0 mm   083 319   083 320   046 800   046 801   083 489   083 490   053 708   053 710   U-Cogged   U-Cogged   U-Cogged   U-Cogged   056 193   056 193   056 195   056 195   056 207   056 207   056 209   056 209   Ref. S-0025-D   OM-186 895 Page 28   Download from Www.Somanuals.com. All Manuals Search And Download.   Notes   OM-186 895 Page 29   Download from Www.Somanuals.com. All Manuals Search And Download.   Notes   OM-186 895 Page 30   Download from Www.Somanuals.com. All Manuals Search And Download.   Effective January 1, 1999   (Equipment with a serial number preface of “KK” or newer)   Warranty Questions?   Call   1-800-4-A-MILLER   for your local   Miller distributor.   This limited warranty supersedes all previous Miller warranties and is exclusive with no other   guarantees or warranties expressed or implied.   LIMITED WARRANTY − Subject to the terms and conditions   below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants   to its original retail purchaser that new Miller equipment sold   after the effective date of this limited warranty is free of defects   in material and workmanship at the time it is shipped by Miller.   THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER   WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE   WARRANTIES OF MERCHANTABILITY AND FITNESS.   * APT, ZIPCUT & PLAZCUT Model Plasma Cutting   Torches   * * * * Remote Controls   Accessory Kits   Replacement Parts (No labor)   Spoolmate 185   Your distributor also gives   you ...   Within the warranty periods listed below, Miller will repair or   replace any warranted parts or components that fail due to   such defects in material or workmanship. Miller must be   notified in writing within thirty (30) days of such defect or   failure, at which time Miller will provide instructions on the   warranty claim procedures to be followed.   Miller’s True Blue® Limited Warranty shall not apply to:   Service   1. Items furnished by Miller, but manufactured by others,   such as engines or trade accessories. These items are   covered by the manufacturer’s warranty, if any.   You always get the fast,   reliable response you   need. Most replacement   parts can be in your   hands in 24 hours.   2. Consumable components; such as contact tips, cutting   nozzles, contactors, brushes, slip rings, relays or parts   that fail due to normal wear.   Miller shall honor warranty claims on warranted equipment   listed below in the event of such a failure within the warranty   time periods. All warranty time periods start on the date that   the equipment was delivered to the original retail purchaser, or   one year after the equipment is sent to a North American   distributor or eighteen months after the equipment is sent to an   International distributor.   Support   3. Equipment that has been modified by any party other   than Miller, or equipment that has been improperly   installed, improperly operated or misused based upon   industry standards, or equipment which has not had   reasonable and necessary maintenance, or equipment   which has been used for operation outside of the   specifications for the equipment.   Need fast answers to the   tough welding questions?   Contact your distributor.   The expertise of the   distributor and Miller is   there to help you, every   step of the way.   1. 5 Years Parts − 3 Years Labor   * * Original main power rectifiers   Inverters (input and output rectifiers only)   MILLER PRODUCTS ARE INTENDED FOR PURCHASE   AND USE BY COMMERCIAL/INDUSTRIAL USERS AND   PERSONS TRAINED AND EXPERIENCED IN THE USE   AND MAINTENANCE OF WELDING EQUIPMENT.   2. 3 Years — Parts and Labor   * * * * * * Transformer/Rectifier Power Sources   Plasma Arc Cutting Power Sources   Semi-Automatic and Automatic Wire Feeders   Inverter Power Supplies   In the event of a warranty claim covered by this warranty, the   exclusive remedies shall be, at Miller’s option: (1) repair; or (2)   replacement; or, where authorized in writing by Miller in   appropriate cases, (3) the reasonable cost of repair or   replacement at an authorized Miller service station; or (4)   payment of or credit for the purchase price (less reasonable   depreciation based upon actual use) upon return of the goods   at customer’s risk and expense. Miller’s option of repair or   replacement will be F.O.B., Factory at Appleton, Wisconsin, or   F.O.B. at a Miller authorized service facility as determined by   Miller. Therefore no compensation or reimbursement for   transportation costs of any kind will be allowed.   Intellitig   Engine Driven Welding Generators   (NOTE: Engines are warranted separately by the   engine manufacturer.)   3. 1 Year — Parts and Labor   * Motor Driven Guns (w/exception of Spoolmate   185)   TO THE EXTENT PERMITTED BY LAW, THE REMEDIES   PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE   REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR   DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR   CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF   PROFIT), WHETHER BASED ON CONTRACT, TORT OR   ANY OTHER LEGAL THEORY.   * * * * * * * * * * * * * * Process Controllers   Positioners and Controllers   Automatic Motion Devices   Robots   IHPS Power Sources   Water Coolant Systems   HF Units   ANY EXPRESS WARRANTY NOT PROVIDED HEREIN   AND ANY IMPLIED WARRANTY, GUARANTY OR   REPRESENTATION AS TO PERFORMANCE, AND ANY   REMEDY FOR BREACH OF CONTRACT TORT OR ANY   OTHER LEGAL THEORY WHICH, BUT FOR THIS   Grids   Spot Welders   PROVISION,   MIGHT   ARISE   BY   IMPLICATION,   Load Banks   OPERATION OF LAW, CUSTOM OF TRADE OR COURSE   OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF   MERCHANTABILITY OR FITNESS FOR PARTICULAR   PURPOSE, WITH RESPECT TO ANY AND ALL   EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND   DISCLAIMED BY MILLER.   SDX Transformers   Miller Cyclomatic Equipment   Running Gear/Trailers   Plasma Cutting Torches (except APT, ZIPCUT &   PLAZCUT Models)   Some states in the U.S.A. do not allow limitations of how long   an implied warranty lasts, or the exclusion of incidental,   indirect, special or consequential damages, so the above   limitation or exclusion may not apply to you. This warranty   provides specific legal rights, and other rights may be   available, but may vary from state to state.   * * Deutz Engines (outside North America)   Field Options   (NOTE: Field options are covered under True   Blue® for the remaining warranty period of the   product they are installed in, or for a minimum of   one year — whichever is greater.)   In Canada, legislation in some provinces provides for certain   additional warranties or remedies other than as stated herein,   and to the extent that they may not be waived, the limitations   and exclusions set out above may not apply. This Limited   Warranty provides specific legal rights, and other rights may   be available, but may vary from province to province.   4. 6 Months — Batteries   5. 90 Days — Parts   * MIG Guns/TIG Torches   miller_warr 1/99   Download from Www.Somanuals.com. All Manuals Search And Download.   Owner’s Record   Please complete and retain with your personal records.   Model Name   Purchase Date   Distributor   Address   Serial/Style Number   (Date which equipment was delivered to original customer.)   City   State   Zip   Resources Available   Always provide Model Name and Serial/Style Number.   Contact your Distributor for:   Welding Supplies and Consumables   Options and Accessories   Personal Safety Equipment   Service and Repair   To locate distributor nearest you call   1-800-4-A-Miller.   Miller Electric Mfg. Co.   An Illinois Tool Works Company   1635 West Spencer Street   Appleton, WI 54914 USA   Replacement Parts   Training (Schools, Videos, Books)   International Headquarters−USA   USA Phone: 920-735-4505 Auto-Attended   USA & Canada FAX: 920-735-4134   International FAX: 920-735-4125   Technical Manuals (Servicing Information   and Parts)   Circuit Diagrams   European Headquarters −   United Kingdom   Phone: 44 (0) 1204-593493   FAX: 44 (0) 1204-598066   Welding Process Handbooks   Contact the Delivering Carrier for:   File a claim for loss or damage during   shipment.   For assistance in filing or settling claims,   contact your distributor and/or equipment   manufacturer’s Transportation Department.   PRINTED IN USA   © 1999 Miller Electric Mfg. Co. 9/98   Download from Www.Somanuals.com. All Manuals Search And Download.   |