Maytag Cooktop MGC7430W User Manual

30" (76.2 cm) and 36" (91.4 cm) Gas Built-In Cooktop  
LOCATION REQUIREMENTS  
PRODUCT MODEL NUMBERS  
MGC7430W  
MGC7536W  
Electrical  
MGC7630W  
MGC7636W  
IMPORTANT: Observe all governing codes and ordinances. Do not  
obstruct flow of combustion and ventilation air.  
It is the installer’s responsibility to comply with installation clearances  
specified on the model/serial rating plate. The model/serial rating plate is  
located on the underside of the cooktop base.  
A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is required. A  
time-delay fuse or circuit breaker is also recommended. It is  
recommended that a separate circuit serving only this cooktop be  
provided.  
Type of Gas  
A
Natural Gas: This cooktop is design-certified by CSA International for  
use with Natural gas or, after proper conversion, for use with LP gas.  
This cooktop is factory set for use with Natural gas. If converting to LP  
gas, see the “LP Gas Conversion” instructions provided in the package  
containing literature. The model/serial rating plate located on the  
underside of the cooktop base has information on the types of gas that  
can be used. If the types of gas listed do not include the type of gas  
available, check with the local gas supplier.  
LP Gas Conversion: Conversion must be done by a qualified service  
technician.  
No attempt shall be made to convert the cooktop from the gas specified  
on the model/serial rating plate for use with a different gas without  
consulting the serving gas supplier. See the Gas Conversion instructions  
provided in the package containing literature.  
Gas Supply Line  
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the cooktop  
A. Model/serial rating plate  
To eliminate the risk of burns or fire by reaching over heated surface  
units, cabinet storage space located above the surface units should be  
avoided. If cabinet storage is to be provided, the risk can be reduced by  
installing a range hood that projects horizontally a minimum of 5"  
(12.7 cm) beyond the bottom of the cabinets.  
The cooktop must be a specified cooktop that is approved to be installed  
either alone or over an undercounter built-in oven. Check the cooktop  
base approved installation label for your cooktop model number and  
approved combinations of cooktops and ovens that can be installed. If  
you do not find this label, your cooktop may not be approved for use  
over an undercounter built-in oven. Contact your dealer to confirm that  
your cooktop is approved.  
location. A smaller size pipe on longer runs may result in insufficient  
gas supply. Pipe-joint compounds that resist the action of LP gas must  
be used. Do not use TEFLON®† tape. With LP gas, piping or tubing size  
should be ¹⁄₂" minimum. Usually, LP gas suppliers determine the size  
and materials used in the system.  
Ovens approved for this type of installation will have an approval label  
located on the top of the oven. If you do not find this label, contact your  
dealer to confirm that your oven is approved. Refer to oven  
manufacturer’s Installation Instructions for approval for built-in  
undercounter use and proper cutout dimensions.  
Flexible metal appliance connector:  
If local codes permit, use a ¹⁄₂" or ³⁄₄" I.D. flexible stainless steel tubing  
gas connector, designed  
by CSA to connect the  
cooktop to the rigid gas  
supply line.  
The cooktop should be installed in a location away from strong draft  
areas, such as windows, doors and strong heating vents or fans.  
All openings in the wall or floor where cooktop is to be installed must be  
sealed.  
A ¹⁄₂" male pipe thread is needed for connection to the female pipe  
threads of the inlet to the cooktop pressure regulator.  
Do not kink or damage the flexible metal tubing when moving the  
cooktop.  
IMPORTANT: To avoid damage, check with your builder or cabinet  
supplier to make sure that the materials used will not discolor, delaminate  
or sustain other damage.  
Mobile Home - Additional Installation Requirements  
Rigid pipe connection:  
The installation of this cooktop must conform to the Manufactured Home  
Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the  
Federal Standard for Mobile Home Construction and Safety, Title 24, HUD  
Part 280). When such standard is not applicable, use the Standard for  
Manufactured Home Installations, ANSI A225.1/NFPA 501A or with local  
codes.  
The rigid pipe connection requires a combination of pipe fittings to obtain  
an in-line connection to the cooktop.  
The rigid pipe must be level with the  
cooktop connection. All strains must  
be removed from the supply and fuel  
lines so cooktop will be level and in  
line.  
In Canada, the installation of this cooktop must conform with the current  
standards CAN/CSA-A240-latest edition, or with local codes.  
Must include a shutoff valve:  
The supply line must be equipped with a manual shutoff valve. This  
valve should be located in the same room but external to the cooktop  
opening, such as an adjacent cabinet. It must be accessible without  
removing the cooktop, and it should be in a location that allows ease of  
opening and closing. Do not block access to shutoff valve. The valve is  
for turning on or shutting off gas to the cooktop.  
B
A. Gas supply line  
B. Shutoff valve “open” position  
A
C. To cooktop  
C
†®TEFLON is a registered trademark of E.I. Du Pont Nemours and Company.  
Page 1 of 2  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10526090A  
7/9/13  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Learning Resources Skin Care Product LER3562 User Manual
Lenovo Personal Computer 10A4 User Manual
Liesegang Projector dv335 User Manual
LSI Network Card U40HVD User Manual
LST Smoke Alarm ASA 45681 210 User Manual
Makita Chainsaw DCS3500 User Manual
Makita Drill DA3000R User Manual
M Audio Drums Drums User Manual
Melissa Electric Shaver 238 101 User Manual
Metra Electronics Automobile Accessories AW PW22 User Manual