		 METRObility Optical Systems Power Supply ACPS 17HS User Manual  | 
	
| 	
		 Operating Features of the Power Supply   
					The ACPS-17HS and DCPS-17HS load-sharing power sup-   
					plies are designed for AC and DC power sources, respec-   
					tively. Both power supplies are field-replaceable.   
					Technical Specifications   
					Input Power   
					ACPS-17HS ___________________ 100-120/200-240V AC   
					___________________________ 50-60Hz, 2A   
					DCPS-17HS __________________________ 48V DC, 4.9A   
					When two power supplies are installed in the Radiance   
					R5000 Central Service Platform, they operate in tandem and   
					share the load. If the power source to one of the supplies fails   
					or is removed, the other power supply automatically provides   
					the entire power load to the platform. This setup provides   
					both the platform and the network with uninterrupted service.   
					It also decreases the demand placed upon an individual   
					power supply, thus prolonging its life.   
					Weight   
					Radiance   
					R5000 Power Supply   
					ACPS-17HS ________________________________ 3.25 lb   
					DCPS-17HS ___________________________________ 3 lb   
					Environmental   
					Operating Temperature _____________________ 0º to 50º C   
					Storage Temperature _____________________ -30º to 70º C   
					Relative Humidity ___________ 5% to 95% non-condensing   
					Dimensions ______________________ 7.5"L x 7"W x 3.5"H   
					___________ (19.1cm L x 17.8cm W x 8.9cm H)   
					I.T.E.   
					US   
					E116552   
					PWR   
					C 
					DCPS-17HS   
					SOURCES BEFORE SERVICING   
					When the power (PWR) LED on the front panel of the power   
					supply is lit, it indicates that the power supply is turned on,   
					connected to an active power source, and providing power to   
					the platform’s backplane. Because they are load-sharing,   
					when two power supplies are installed and active in a single   
					platform, the LEDs on both supplies are lit simultaneously.   
					LISTED   
					DISCONNECT ALL POWER   
					_________________   
					PRODUCT SERVICE   
					Made in   
					DC IN 48V, 4.9A   
					The information contained in this document is assumed to be correct and   
					current. The manufacturer is not responsible for errors or omissions and   
					reserves the right to change specifications at any time without notice.   
					CAUTION   
					RISK OF ELECTRIC   
					SHOCK, DO NOT OPEN   
					THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,   
					OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:   
					(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,   
					AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,   
					INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.   
					An optional display card is available for vis-   
					ible verification of operating status from the   
					front of the platform. The R500-D, which   
					must be installed in slot 16 or 17, provides   
					two LEDs labeled A and B. When lit, these   
					LEDs indicate that their corresponding   
					This publication is protected by the copyright laws of the United States   
					and other countries, with all rights reserved. No part of this publication   
					may be reproduced, stored in a retrieval system, translated, transcribed,   
					or transmitted, in any form, or by any means manual, electric, electronic,   
					electromagnetic, mechanical, chemical, optical or otherwise, without prior   
					explicit written permission of METRObility Optical Systems, Inc.   
					I.T.E.   
					US   
					E116552   
					PWR ACPS-17HS   
					C 
					LISTED   
					DISCONNECT ALL POWER   
					SOURCES BEFORE SERVICING   
					_________________   
					PRODUCT SERVICE   
					AC IN   
					100-120   
					/ 
					200-240V   
					50-60Hz,   
					2A   
					© 2001 METRObility Optical Systems, Inc.   
					All rights reserved. Printed in USA.   
					power supplies are installed properly, con-   
					PWR   
					A 
					nected to an active power source, turned on,   
					B 
					FACTORY DEFAULT   
					SETTING 115V   
					WARNING   
					and providing power to the platform’s   
					CAUTION   
					RISK OF ELECTRIC   
					SHOCK, DO NOT OPEN   
					backplane. When two power supplies are in-   
					THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,   
					OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:   
					(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE,   
					AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,   
					INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.   
					R500-D   
					Front Panel   
					Display Card   
					stalled and active in a single platform, both   
					LEDs are lit simultaneously.   
					25 Manchester Street, Merrimack, NH 03054 USA   
					tel: 603-880-1833   
					• 
					fax: 603-594-2887   
					Installation and User Guide   
					
					5660-000024 B   
					8/01   
					Models: ACPS-17HS / DCPS-17HS   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |