| P223 FLUX AWS A5.17-97: F7A4-EM12K and A5.23-97: F8A2-EA1-A2   ® Lincolnweld P223 flux is an industry • Excellent weld profiles with straight PRODUCT INFORMATION   standard for spiral pipe welding on   up to X80 grade pipe, especially   where good impact properties are   required. It is also well-suited for   longitudinal seam welding on pipe,   producing a low bead profile with   very straight edges, while minimizing   undercuts. Its fast freezing slag   makes it ideal for even small diame-   ter pipe. In most cases, the slag is   self-peeling. For these same rea-   sons, P223 is an excellent choice for   many two-pass welding applications.   While designed for two-pass welding   applications, P223 is a neutral flux   which is also suitable for use in mul-   tiple pass welding with mild steel   and low alloy electrodes.   and consistent weld bead edges.   • Basicity Index: 1.60   • Fast freezing slag makes P223   suitable for smaller diameter pipe.   • Particle Size:   +12 Mesh 2% max.   -12/+100 Mesh 96% min.   -100 Mesh 2% max.   • Slag is self-peeling on most appli-   cations.   3 • Density: 1.3 g/cm   • Designed to deliver Charpy   V-Notch impact properties that   exceed most line pipe require-   ments.   CONFORMANCES   For Mild Steel:   ® Lincolnweld L-61   • Low diffusible hydrogen levels.   AWS A5.17-97: F7A4-EM12K   ASME SFA-5.17   • Manufactured under a quality   system certified to ISO 9001.   For Low Alloy Steel:   ® Lincolnweld L-70   AWS A5.23-97: F8A2-EA1-A2   ASME SFA-5.23   TYPICAL APPLICATIONS   • Oil and gas line pipe fabrication   through X-80 grades.   • Single pass or multiple pass   welding.   RECOMMENDED ELECTRODES   ADVANTAGE LINCOLN   Single Pass or Two-Pass Welds:   ® • The weld deposits of neutral   P223 flux are extremely resistant   to procedural variations.   Lincolnweld L-61, AWS EM12K   • Single arc or multiple arc (up to   3 arc tandem welding).   ® Lincolnweld L-70, AWS EA1   (intended for applications requiring   robust Charpy impact properties).   • Straight seam or spiral seam   welding.   • Fast solidification of weld metal   and slag for excellent bead   appearance.   • Low dust levels make handling at   the work station clean and easy.   Tested on Pipe   (1)   MECHANICAL PROPERTIES – Two-pass seam weld on 0.688" wall X-65 pipe   AC/AC two-wire tandem arc procedure   Charpy V-Notch   ft•lbf (Joules)   @ 0ºF (-18ºC)   Charpy V-Notch   ft•lbf (Joules)   @ -20ºF (-29ºC)   Charpy V-Notch   ft•lbf (Joules)   @ -40ºF (-40ºC)   Charpy V-Notch   ft•lbf (Joules)   @ -60ºF (-51ºC)   Flux/Wire   Combination   Actual Test Results   As-welded   75   (101)   76   (103)   87   (117)   45   (61)   P223/L-61   Actual Test Results   As-welded   113   (153)   101   (136)   99   (134)   82   (111)   P223/L-70   (1)Mechanical property results obtained on single pass or two-pass welds will vary with base plate composition,   welding procedure, heat input, etc. These results are shown only to demonstrate the potential for the products   being used.   Publication C5.10.1 12/03   Download from Www.Somanuals.com. All Manuals Search And Download.   P223 FLUX AWS A5.17-97: F7A4-EM12K and A5.23-97: F8A2-EA1-A2   DIFFUSIBLE HYDROGEN   - As Tested per AWS A4.3-93   PACKAGING   (mL/100g   Lincolnweld®   FluxPaper   50 lb. (23 kg)   Bag   weld deposit)   Requirements   AWS F7A4-EM12K   Not Specified   3.7   P223   EDS30636   Actual Test Results   P223/L-61   Requirements   AWS F8A2-EA1-A2   Not Specified   4.2   Actual Test Results   P223/L-70   TYPICAL OPERATING PROCEDURES – Two-run seam weld on 0.688" wall X-65 pipe AC/AC two-wire tandem   arc procedure. 0.25" centered land, 90˚ included angle each side, 5˚ push lead arc, 20˚ push angle trail arc.   Diameter   Polarity   Approx.   Wire Feed   Speed   Arc   Voltage   (volts)   Travel   Speed   in/min (m/min)   CTWD(1)   Current   (amps)   Lead/Trail Spacing   in/min (m/min)   Side 1   Lead Arc – P223/L-61 or L-70   5/32" (4.0 mm)   90 (2.3)   50 (1.3)   35   36   920   41 (1.04)   41 (1.04)   AC   1-1/2" (38.1 mm)   5/8" (15.88 mm)   Trail Arc – P223/L-61 or L-70   5/32" (4.0 mm)   AC   640   1-1/2" (38.1 mm)   5/8" (15.88 mm)   Side 2   Lead Arc – P223/L-61 or L-70   5/32" (4.0 mm)   100 (2.5)   48 (1.2)   36   41   980   620   38 (.97)   38 (.97)   AC   1-1/2" (38.1 mm)   5/8" (15.88 mm)   Trail Arc – P223/L-61 or L-70   5/32" (4.0 mm)   AC   1-1/2" (38.1 mm)   5/8" (15.88 mm)   (1) CTWD (Contact Tip to Work Distance). Subtract 1/4" to calculate Electrical Stickout.   P223 Flux 12/03   [3]   Download from Www.Somanuals.com. All Manuals Search And Download.   P223 FLUX AWS A5.17-97: F7A4-EM12K and A5.23-97: F8A2-EA1-A2   T E S T R E S U L T S   Test results for mechanical properties, deposit or electrode composition and diffusible hydrogen levels were obtained from a weld produced and tested according to prescribed   standards, and should not be assumed to be the expected results in a particular application or weldment. Actual results will vary depending on many factors, including, but not limited   to, weld procedure, plate chemistry and temperature, weldment design and fabrication methods. Users are cautioned to confirm by qualification testing, or other appropriate means,   the suitability of any welding consumable and procedure before use in the intended application.   C U S T O M E R A S S I S T A N C E P O L I C Y   The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet the   needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for advice or information about their use of our products. We respond   to our customers based on the best information in our possession at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability,   with respect to such information or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customer’s particular purpose, with respect to   such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or correcting any such information or advice once it has   been given, nor does the provision of information or advice create, expand or alter any warranty with respect to the sale of our products.   Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains the sole responsibility   of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in applying these types of fabrication methods and service requirements.   THE LINCOLN ELECTRIC COMPANY   Download from Www.Somanuals.com. All Manuals Search And Download.   |