Kodak Scanner A 61097 User Manual

DIGITAL SCIENCETM and  
IMAGELINKTM Scanners  
Installation Questionnaire  
Instructions  
A-61097  
Part Number 4C8894  
Mode Setup Instructions  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Software Installation Procedure  
Follow these steps to install the software:  
1. Insert the Mode Setup Software diskette into the drive.  
2. Type A:INSTALL next to the DOS prompt and press Return/Enter.  
If the disk drive on your unit is not designated as the A drive, substitute  
the correct drive designation in this command string.  
Microimager IL70 * IL70 AFM  
Scanner IL900 * IL923  
Microimager/Scanner DS990 * Scanner DS9500  
Mode Setup Software  
Copyright (c) 1989-1997  
Eastman Kodak Company  
All Rights Reserved  
Press Any Key to Install, ESCAPE to Exit  
3. Press any key.  
Mode Setup Software  
Directory Information  
Drive To Install From: A  
Drive To Install To: C  
Directory To Be Installed To:  
\SETUP  
ESCAPE to Abort  
1-2  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Enter the desired drive and directory designations and press Enter.  
Directory Information  
Drive To Install From: A  
Drive To Install To: C  
Directory To Be Installed To:  
\SETUP  
ESCAPE to Abort  
[Press ENTER to Accept, any other key to Edit]  
5. Press Enter to continue the logon procedure. Press any other key to  
alter the drive and directory designations.  
Mode Setup Software  
Please Wait While Files Are Being Copied To Your  
Destination Drive.  
Use Existing Directory ([Y/N]?  
Hit [N]o to Select New Directory  
6. Enter an N to abort and designate a different directory. Enter a Y to  
continue, replacing the files within the designated directory.  
A-61097 May 1997  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
During the installation procedure, the following window will appear if you  
don’t have the files and buffers set correctly in the config.sys file:  
Mode Setup Software  
INSTALLING  
Please Wait While Files  
Are Being Copied ToYour  
Destination Drive.  
The CONFIG.SYS  
File Needs To  
Be Checked To Make  
Sure That  
BUFFERS=40 FILES=40  
Next, the following windows will appear:  
Mode Setup Software  
INSTALLING  
Please Wait While Files  
Are Being Copied To Your  
Destination Drive.  
Mode Setup Software  
INSTALLING  
Please Wait  
Copying File: setup.zip  
1-4  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REGISTRATION  
Please enter the name of the registered user below:  
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _  
Please Wait While Files  
Are Being Copied To Your  
Destination Drive.  
FILE COPY COMPLETE  
7. Type in user name. Press Return/Enter.  
Type “setup” in c:\setup directory to start Mode Setup  
8. Press any key to return to DOS.  
9. Eject the Mode Setup Software diskette.  
10. Type: cd setup. The SETUP directory is displayed.  
11. Type: setup. This starts the program.  
A-61097 May 1997  
1-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Logon Procedure  
After the installation procedure has been performed, follow these steps to  
log on to the Mode Setup Software:  
1. Access DOS.  
2. Change the directory to correspond to the directory designated during  
the installation procedure.  
3. Type setup and press Return/Enter.  
* EASTMAN KODAK COMPANY  
*
*
*
*
*
*
*
*
Model 30  
Model 70/AFM * Model 70  
Model 900 * Model 923  
* Model DS990 * Model DS9500  
This software is the property of  
Eastman Kodak Company.  
It is not to be sold or leased  
in any form. Use by any other  
individual is illegal and subject  
to penalties under the copyright  
laws of the United States.  
Version  
3.30  
Connect via RS-232  
Connect via Modem  
Release Date  
MM-DD-YY  
Exit  
Copyright  
Eastman Kodak Company  
1989-1997  
4. Select Connect via RS-232 and press Return/Enter.  
KODAK IMAGELINK (tm) / DIGITAL SCIENCE (tm)  
Microimager Models 30 & 70  
Microimager Model 70/AFM  
Scanner 900 & 923  
Microimager/Scanner DS990  
Scanner DS9500  
1) Attach RS-232 Cable  
2) Turn Operator Power Switch ON  
3) Press “ENTER/RETURN” Key  
Continue  
Exit  
1-6  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Select Continue.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Mode Configuration  
End Session  
Using the Mode Setup Software  
This section provides guidelines and conventions that will assist you in  
using the Mode Setup Software.  
· There are two levels of definitions: Machine definitions, which apply to  
all modes; and Mode definitions, which apply to one mode.  
· Each defined option requires you to select a displayed option or enter a  
value.  
· If asked to select an option:  
— Use the arrow keys to position the highlight cursor over the desired  
option.  
— Press the Return/Enter key.  
· If asked to enter a value:  
— Typically, the highlight cursor will appear over the input field, if it  
does not, use the arrow keys to position the highlight cursor over the  
input field.  
— Enter (type) the desired value, using the keyboard or numeric  
keypad.  
— Press the Return/Enter key.  
A-61097 May 1997  
1-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
· Each window should contain an option entitled Previous Menu.  
Typically, you are returned to the previous menu after completing a  
definition. If you are not returned to the previous menu after completing  
a definition, or you want to return without altering the default or  
previously defined value, select the Previous Menu option:  
— Use the arrow keys to position the highlight cursor over the Previous  
Menu option or press the PAGEDOWN key to automatically position  
the highlight cursor over the Previous Menu option.  
— Press the Return/Enter key.  
· If you receive a message indicating that an accessory is not installed,  
press the Return/Enter key to continue. This message indicates that  
the option selected requires an accessory which is not physically  
installed and/or properly defined to the software. In either instance,  
contact your Kodak service representative to properly install and/or  
define the accessory.  
· If you receive a message that indicates a selection is not available,  
press the Return/Enter key to continue. This message indicates that  
the option selected is not available in the mode selected, or is not  
available for the machine configuration.  
Using the Mode Setup Software Questionnaire and Instructions  
There are two pieces of documentation designed for use with the Mode  
Setup Software: the Installation Instructions, which provide information on  
how to install, access and use the software to define the available options;  
and the Installation Questionnaire, which provides a convenient form on  
which to record all of the machine and mode definitions.  
The Installation Instructions describe all of the available options which can  
be defined using the Mode Setup Software.  
NOTE: Not all options are available using a given machine configuration.  
Hence, each definition is accompanied by a configuration key  
which indicates whether or not the option is available for each  
machine configuration. If you attempt to define an option which is  
not valid under your machine configuration, you will receive a  
message which indicates that the option is not available. Simply  
press the Return/Enter key to continue.  
Follow the Installation Instructions in order to define all of the available  
options, recording each definition on the Installation Questionnaire form,  
found in chapter 4. The Installation Questionnaire form requires that you  
write your selections in the space provided. Due to space limitations,  
Appendix C: Recommended Questionnaire Entries contains  
recommended shorthand entries for the various options you may enter.  
This is provided so that there is consistency among users, making it  
easier for other users to decipher your selections.  
1-8  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Logout Procedure  
Once you have completed the installation, the following sequence of steps  
may be used to log out of the system.  
From the Mode Configuration window:  
1. Select Save & End Session if you wish to save all of the definitions or  
Don’t Save & End Session if you do not wish to save all of the  
definitions.  
You will be returned to the Configuration window.  
2. Select End Session from the Configuration window.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writ
DP-12 Print Template  
Fixed Field Delimiter  
Please confirm ending session  
Set System Clock  
Continue Session  
Version Numbers  
User COIN Port Proto
Custom Check Digit  
End Session  
OI Hardware Charact
Save Configuration to
Load Configuration from PC  
Mode Configuration  
End Session  
3. Select End Session to exit to DOS or Continue Session if you do not  
want to exit at this time.  
A-61097 May 1997  
1-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 Machine Definitions  
The following section lists the items on the Mainframe Configuration Menu  
that may be selected for definition.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Mode Configuration  
End Session  
The following list appears for each option. A black square indicates that  
the option is available on that machine. A white square indicates that the  
option is not available on that machine. An example is illustrated below:  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
A-61097 May 1997  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display Machine Accessories  
This option displays the status of the various machine accessories and is  
for viewing only; no selections or entries are made.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Display Machine Accessories.  
2. Press Return/Enter to close the Accessory Status window.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Accessory  
Endorser  
Check Stacker  
Image Marker  
Status  
Not Present  
Not Present  
Present  
Alarm Tone  
Film Writing  
Present  
Present  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Adv Doc Control  
Patch Head #1  
Patch Head #2  
Set System Clock  
Version Numbers  
Front BC Board  
Front DSA  
User COIN Port Protocol  
Rear BC Board  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Rear DSA  
Print Controller  
Primary DP-1  
Present  
Not Present  
Load Configuration from PC  
Mode Configuration  
Secondary DP-1  
Doc Printer 12  
OCR  
Not Present  
Present  
Not Present  
End Session  
Document Sorter  
Not Present  
NOTE: On scanners 900, 923, and 9500, Image Marker and Film Writing  
are not available.  
On a machine with DSA:  
Patch Head #2 = N/A  
Front DSA = 990/923/IL70  
Rear DSA = 990 D Only  
2-2  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Machine ID Number  
This option establishes a unique identification number for each unit in a  
multiple-unit installation. The default is 00.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Machine ID Number.  
2. Enter a number from 00-99.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg 5  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Enter machine id below  
00  
Mode Configuration  
To Change: Enter Value  
To Retain: Press Enter  
End Session  
A-61097 May 1997  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display Language  
This option defines the primary display language. The default is English.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Display Language.  
2. Select the desired language option.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Language  
English  
Other Language  
Previous Menu  
Mode Configuration  
End Session  
NOTE: Other Language should be selected only if a foreign language  
prom has been installed. If selected, indicate which foreign  
language prom has been installed when filling in the Installation  
Questionnaire.  
2-4  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Measurement System  
This option defines the primary measurement system. English uses inches  
as the primary unit of measure. Metric uses millimetres as the primary unit  
of measure. The default is English.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Measurement System.  
2. Select the desired unit of measurement.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Units  
English  
Metric  
Previous Menu  
Mode Configuration  
End Session  
A-61097 May 1997  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programmable Function Keys (P-Keys)  
This option defines the functions performed by the programmable keys.  
Refer to Appendix B: Function Codes to determine which function codes  
and formats to use when programming the P-Keys.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Programmable Function Keys.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Mode Configuration  
End Session  
Key  
P1  
Definition  
P2  
P3  
P4  
P5  
P6  
P7  
P8  
P9  
P10  
Prev Previous Menu  
2-6  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The default values are displayed in the Key Definition table.  
The following values apply only to the Scanner 9500.  
Key  
P1  
Definition  
f37  
Calibrate  
P2  
P3  
f98f38 Stop, End of Job  
f01,01 Change to Mode 1  
P4  
P5  
f01,02 Change to Mode 2  
f01,03 Change to Mode 3  
P6  
P7  
f01,04 Change to Mode 4  
f01,05 Change to Mode 5  
P8  
P9  
f01,06 Change to Mode 6  
f01,07 Change to Mode 7  
P10  
ff01,08 Change to Mode 8  
Previous Menu  
Prev  
The following values apply only to the Microimager 70 and Microimager 70/  
AFM:  
Key  
P1  
Definition  
Count only, toggle  
f04,2  
f45  
P2  
P3  
Print test  
f09  
Total document count  
P4  
P5  
f08  
f33  
Last Image Address  
Roll number  
P6  
P7  
P8  
P9  
P10  
f30  
f44  
f46  
f07  
f35  
Amount of film remaining  
Omit printing on next document only  
Print position  
Level 0  
Cassette ID number  
The following default values apply only to the Scanner 900/923.  
Key  
P1  
Definition  
f37  
Calibrate  
P2  
P3  
P4  
f98f38 Stop, End of Job  
f01,01 Change to Mode 1  
f01,02 Change to Mode 2  
P5  
P6  
f01,03 Change to Mode 3  
f01,04 Change to Mode 4  
P7  
P8  
f01,05 Change to Mode 5  
f01,06 Change to Mode 6  
P9  
f01,07 Change to Mode 7  
ff01,08 Change to Mode 8  
P10  
A-61097 May 1997  
2-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The following default values apply only to the Scanner/Microimager 990:  
Key  
P1  
Definition  
f04,2 Count only, toggle  
P2  
P3  
P4  
P5  
P6  
P7  
f45 Print test  
f09 Total document count  
f08 Last Image Address  
f37 Calibrate  
f30  
Amount of film remaining  
f44 Omit printing on next document only  
P8  
P9  
f46  
Print position  
f07 Level 0  
P10 f98f38Stop, End-of-Job  
To enter a function code, type an f (lower case) followed by a two-digit  
code (i.e., f04). Any additional information, such as a zero (0) to disable a  
function, a one (1) to enable a function, or a two (2) to toggle a function, is  
entered by typing a comma (,) followed by the additional information (i.e.,  
f04,1 enables counting only).  
Multiple function codes are entered as a string of individual function codes  
with no spaces or delimiters in between (i.e., f98f38 stops the machine  
and then issues an end-of-job indicator).  
When using a Microimager 70 without the Advanced Function Module  
installed, only two of the P-Keys are programmable: P5 and P10.  
When using a Microimager 70 with the Advanced Function Module  
installed, Scanner 900, Scanner 923, Scanner/Microimager 990, or  
Scanner 9500, all P-Keys are programmable.  
P-Keys are programmed using the following sequence of steps:  
1. Select a P-Key (P1 – P10).  
2. Press Return/Enter.  
3. Enter the desired function.  
Repeat this sequence for each P-Key you wish to (re)program.  
2-8  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Date Format  
This option defines the date display format, both the date format and  
delimiter. Refer to Description 1: Date Format Samples for a description  
of the available formats. The default is mmddyy. The default delimiter is a  
slash (/).  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Date Format.  
2. Select a date format.  
3. Select a date delimiter.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Date Format  
mmddyy  
mmdd  
ddmmmyy  
ddmmm  
mmyy  
yddd  
yyddd  
yymmdd  
ddmmyy  
mmmddyyyy  
Example  
12/25/92  
12/25  
25-DEC-92  
25-DEC  
12/92  
2-359  
92-359  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
92.12.25  
25 12 92  
DEC-25-1992  
Date Delimiter  
Slash ("/")  
Dash ("-")  
Period (".")  
Space (" ")  
No Delimiter  
mm = [01-12]  
mmm= [JAN,FEB]  
dd = [01-31]  
ddd = [001-366]  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Mode Configuration  
y
= [0-9]  
End Session  
yy  
= [00-99]  
Previous Menu yyyy = 1990-2000  
A-61097 May 1997  
2-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Description 1: Date Format Samples  
Sample Date  
March 1, 1991  
Slash  
Dash  
Period  
Space  
None  
mmddyy  
mmdd  
03/01/91  
03/01  
03/01/91  
03-01  
03.01.91  
03.01  
03 01 91  
03 01  
030191  
0301  
ddmmmyy  
ddmmm  
mmyy  
01/MAR/91  
01/MAR  
03/91  
01-MAR-91  
01-MAR  
03-91  
01.MAR.91  
01.MAR  
03.91  
01 MAR 91  
01 MAR  
03 91  
01MAR91  
01MAR  
0391  
yddd  
1/060  
1-060  
1.060  
1 060  
1060  
yyddd  
91/060  
91-060  
91.060  
91 060  
91060  
yymmdd  
ddmmyy  
mmmddyyyy  
91/03/01  
01/03/91  
MAR/01/1991  
91-03-91  
01-03-91  
MAR-01-1991  
91.03.01  
01.03.91  
MAR.01.1991  
91 03 01  
01 03 91  
MAR 01 1991  
910301  
010391  
MAR011991  
2-10  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Time Format  
This option defines the time display format. Refer to Description 2: Time  
Format Samples for a description of the available formats. The default is  
12 hour with AM/PM.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Time Format.  
2. Select a specific time format.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Set Time Format  
12 Hour with AM/PM  
Measurement System  
Programmable Function Keys  
Date Format  
12 Hour without AM/PM  
24 Hour  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
Previous Menu  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Mode Configuration  
End Session  
Description 2: Time Format Samples  
Time Format  
12 hour with AM/PM  
12 hour without AM/PM  
24 hour  
What Is Printed  
5:00 PM  
5:00  
17:00  
A-61097 May 1997  
2-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Alarm Tone  
This option defines tone or pitch of the audible alarm. The default is High.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select Alarm Tone.  
2. Select the desired alarm tone pitch.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Alarm Tone  
Low Tone  
High Tone  
Previous Menu  
Mode Configuration  
End Session  
2-12  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Document Printer/Film Writer Messages  
This option defines messages that may be printed by a document printer  
or film writer.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select Doc Printer/Film Writer Msg.  
Messages are limited to thirty-eight (38) characters for Document  
Printer 1 and 2, and Film Writer, and 12 characters for the DP12, and  
can include any character that can be input from a standard keyboard  
(alphabetic, numeric, and special characters).  
NOTE: Alphabetic characters are automatically converted to upper case.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Mode Configuration  
End Session  
A-61097 May 1997  
2-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Message 0 is predefined and cannot be changed.  
Messages 1 through 9 are programmable using the following sequence of  
steps:  
1. Select a message number.  
2. Press Return/Enter.  
3. Enter the desired message text.  
4. Press Return/Enter.  
Msg  
0
Definition  
Diagnostic Message - No Entry Allowed.  
1
2
3
4
5
6
7
8
9
Prev Previous Menu  
2-14  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Print Template Setup  
This option defines as many as ten (10) unique print templates.  
The template definitions are used when programming Document Printer  
12 print definitions. The default print template is Print Template 1, which  
prints Full IA w/No Delimiters on Line 1.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select DP-12 Print Template.  
2. Select a print template (1–10).  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Print Templates  
Print Template 1  
Print Template 2  
Print Template 3  
Print Template 4  
Alarm Tone  
Print Template 5  
Print Template 6  
Print Template 7  
Print Template 8  
Print Template 9  
Print Template 10  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
Previous Menu  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Mode Configuration  
End Session  
A-61097 May 1997  
2-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Follow these steps for each line/item to be printed (maximum twelve  
per template):  
a. Select the next available item number (or Item 1 if this is the first  
item).  
b. Enter a line number corresponding to the line number on the print  
template master.  
c. Select one or more of the print items listed (maximum three items  
per line).  
NOTE: Anything over 12 characters will be truncated.  
Document Printer 12 Print Template #  
Item Line Print Item  
Print Items  
Full IA w/ No Delimiter  
Full IA w/ FF Delimiter  
Fixed Field Only  
1
01 <IA-No Del>  
2
3
4
5
6
7
8
Indexed Fields Only  
Current Field Level  
Number of Spaces to Indent  
Current Day  
Current Date  
Current Time  
Roll Number  
Total Document Count  
Message 1 - 9  
Check Digit  
9
10  
11  
12  
Nothing Printed  
Previous Menu  
Previous Menu  
If Number Spaces to Indent is selected, you must select the desired  
number of spaces.  
No # of Spaces (1..12)  
TO CHANGE: Enter Value  
TO RETAIN: Press Enter  
2-16  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If Check Digit is selected, the following window is displayed:  
Document Printer 12 Print Template #  
Check Digit  
Item Line  
Print Item  
Mod 7A - IA Only  
Mod 11A - IA Only  
Mod 7B - IA Only  
Mod 7B - Full IA  
Mod 10 - IA Only  
Mod 10 - Full IA  
Mod 11B - IA Only  
Mod 11B - Full IA  
Custom - IA Only  
1
01 <IA-No Del> <Message 1>  
2
3
4
5
6
7
8
Custom - Full IA  
9
10  
11  
12  
Previous Menu  
Previous Menu  
3. Select the desired check digit calculation.  
If an option that indicates IA Only is chosen, the level fields of the  
Image Address will be printed; the Fixed Field will not be printed. If an  
option which indicates Full IA is chosen, the Fixed Field and Level  
fields of the Image Address will be printed.  
NOTE: If Custom – IA Only or Custom – Full IA is chosen, the Check  
Digit options must be defined.  
If Message Number is selected, the following window is displayed:  
Document Printer 12 Print Template #  
Message Number  
Item Line  
Print Item  
Message Number 1  
Message Number 2  
Message Number 3  
Message Number 4  
Message Number 5  
Message Number 6  
Message Number 7  
1
2
3
4
5
01 <IA-No Del> <Message 1>  
Message Number 8  
Message Number 9  
6
7
8
Previous Menu  
9
10  
11  
12  
Previous Menu  
4. Select the desired message number.  
The Document Printer 12 may print as many as twelve (12) lines per  
document; each print line can be up to twelve (12) characters long and  
contain as many as three print items. The location of the twelve lines is  
defined in terms of a master template which is thirty-eight (38) lines high  
and twelve characters wide for the small font, and twenty-six (26) lines  
high and twelve (12) characters wide for the large font.  
A-61097 May 1997  
2-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The master template is designed to assist you in the placement of  
information printed by the Document Printer 12.  
Follow these steps to use the master templates:  
1. Obtain a sample of the customer’s document(s).  
2. Determine the starting print position (how far from the leading edge of  
the document printed information should appear).  
3. Draw a line on the sample document which corresponds to the starting  
print position.  
4. Copy the master template onto a transparency.  
5. Align the top (dotted) line of the master template with the line drawn on  
the sample document to achieve proper vertical placement.  
6. Position the master template so that the window is aligned with the  
position of the Document Printer 12 in the transport to achieve proper  
horizontal placement.  
The area in which printed information may appear should now be  
highlighted.  
7. Identify the line numbers which correspond to the area(s) of the  
customer document where you want the printed information to appear.  
Use these line numbers when defining the print template(s).  
NOTE: The placement of printed information will vary slightly due to a  
number of factors, including document transport speed. Expect a  
variation of 0.125 inch between the print template and starting  
print position definitions and the location of actual printed  
information.  
2-18  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dotted line = Starting print position (distance from the leading edge of the document).  
Line 1  
Line 2  
Line 3  
Line 4  
Line 5  
Line 6  
Line 7  
Line 8  
Line 9  
Line 10  
Line 11  
Line 12  
Line 13  
Line 14  
Line 15  
Line 16  
Line 17  
Line 18  
Line 19  
Line 20  
Line 21  
Line 22  
Line 23  
Line 24  
Line 25  
Line 26  
Line 27  
Line 28  
Line 29  
Line 30  
Line 31  
Line 32  
Line 33  
Line 34  
Line 35  
Line 36  
Line 37  
Line 38  
(5.5 lines per inch)  
Vertical placement on the document is dependent upon the position of the  
Document Printer 12 in the transport plate.  
A-61097 May 1997  
2-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dotted line = Starting print position (distance from the leading edge of the document).  
Line 1  
Line 2  
Line 3  
Line 4  
Line 5  
Line 6  
Line 7  
Line 8  
Line 9  
Line 10  
Line 11  
Line 12  
Line 13  
Line 14  
Line 15  
Line 16  
Line 17  
Line 18  
Line 19  
Line 20  
Line 21  
Line 22  
Line 23  
Line 24  
Line 25  
Line 26  
(4 lines per inch)  
Vertical placement on the document is dependent upon the position of the  
Document Printer 12 in the transport plate.  
2-20  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fixed Field Delimiter  
This option defines the fixed field delimiter used in the Image Address  
Display. The default is a Period (.).  
NOTE: The Fixed Field Delimiter doesn’t appear on the display; it  
appears when printing the Image Address.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Fixed Field Delimiter.  
2. Select the desired Fixed Field delimiter.  
NOTE: In order to print the Fixed Field Delimiter using Document Printer  
12, the Image Address must be defined as having eleven (11)  
digits maximum.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Mode Configuration  
Fixed Field Delimiter  
Slash  
Dash  
Period  
Space  
("/")  
("-")  
(".")  
(" ")  
Back-Slash ("\")  
End Session  
Previous Menu  
A-61097 May 1997  
2-21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Set System Clock  
This option sets the system clock.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select Set System Clock.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Set System Clock  
Set Month  
Date  
Set Day  
Set Year  
11-10-1992  
Set Hour  
Alarm Tone  
Set Minute  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Time  
Terminal Time  
Previous Menu  
01:40  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Mode Configuration  
End Session  
If the computer being used to program the unit has its own internal clock:  
2. Select Terminal Time to download the time and date.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Set System Clock  
Measurement System  
Set Month  
Set Day  
Set Year  
Set Hour  
Date  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
11-10-1992  
Set Minute  
Time  
Terminal Time  
Previous Menu  
01:40  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Yes  
No  
Mode Configuration  
End Session  
2-22  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Verify that the terminal time should be downloaded by selecting Yes;  
or to cancel the download, select No.  
If the computer being used to program the unit does not have an internal  
clock or the internal clock is not accurate:  
4. Select the time or date component you wish to define (month, day,  
year, hour or minute).  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Set System Clock  
Measurement System  
Set Month  
Set Day  
Set Year  
Set Hour  
Set Minute  
Date  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
11-10-1992  
Time  
Terminal Time  
Previous Menu  
01:40  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Enter a new month below  
11  
Mode Configuration  
To Change: Enter Value  
To Retain: Press Enter  
End Session  
5. Enter a value for the component selected.  
A-61097 May 1997  
2-23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Version Numbers  
This option displays the current software version(s) installed in the  
machine and is for viewing only; no selections or entries are made.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Version Numbers.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
Version #  
AEC  
: 03.36  
: 04.05  
: 07.02  
: 08.08  
BARCO  
FDS  
MCP  
OI  
: 07.01  
: 02.11  
: 07.04  
: 00.00  
PATCH  
DPC  
OCR  
OI Hardware Character Set  
SCSI  
: 08.06  
Save Configuration to PC  
Load Configuration from PC  
Mode Configuration  
U CAS  
L CAS  
: 01.00  
: 00.00  
End Session  
LAPTOP  
: 02.35  
2. Press Return/Enter to close the Version # window.  
NOTE: The following options are not available on scanners 900, 923, and  
9500:  
AEC: n/a  
FDS: n/a  
U CAS: n/a  
L CAS: n/a  
NOTE: On the Microimager 70:  
SCSI: n/a  
OCR: n/a  
NOTE: On the Microimager 70/AFM:  
SCSI: n/a  
2-24  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User COIN Port Protocol  
This option enables or disables the user COIN port for communication  
protocols associated with OCR data, Document Scanning Array / Bar  
Code Reader, or Customer specified. The default value is Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select User COIN Port Protocol.  
2. Select the desired User COIN Port protocol.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
User COIN Port Protocol  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Disabled  
Bar Code/KDIS Protocol  
User-Defined KDIS Format  
OCR Data Protocol  
Mode Configuration  
User-Defined Protocol  
End Session  
Previous Menu  
Bar Code/KDIS Protocol should be selected when using the Bar Code  
Accessory. This communications protocol does not call for handshaking  
between the Microimager 70, Scanner 900, Scanner 923, Scanner 9500,  
or Scanner/Microimager 990 and the host system.  
OCR Data Protocol should be selected when using the OCR accessory.  
This communications protocol calls for handshaking between the  
Microimager 70, Scanner 900, Scanner 923, or Scanner/Microimager 990  
and the host system.  
A-61097 May 1997  
2-25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If User-Defined Protocol is selected, the following window will be  
displayed:  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
User COIN Port Config  
Measurement System  
Baud Rate  
Parity Bit  
Char. Length  
Handshaking  
Update FF  
9600  
None  
8 Bits  
None  
Update  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Previous Menu  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
User COIN Port Protocol  
Disabled  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Bar Code/KDIS Protocol  
User-Defined KDIS Format  
Load Configuration from PC  
Mode Configuration  
OCR Data Protocol  
User-Defined Protocol  
Previous Menu  
End Session  
Enter the required configuration information by selecting each of the  
configuration options in turn and entering the appropriate values:  
3. Select Baud Rate.  
4. Select the desired baud rate.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
User COIN Port Config  
Measurement System  
Baud Rate  
Parity Bit  
Char. Length  
Handshaking  
Update FF  
9600  
None  
8 Bits  
None  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
Update  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Previous Menu  
Baud Rate  
300  
600  
1200  
2400  
4800  
9600  
19.2  
Mode Configuration  
End Session  
Previous Menu  
2-26  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Select Parity Bit.  
6. Select the desired parity.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
User COIN Port Config  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Baud Rate  
Parity Bit  
9600  
None  
Char. Length  
Handshaking  
Update FF  
8 Bits  
None  
Update  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Previous Menu  
Parity  
No Parity  
Odd Parity  
Even Parity  
Previous Menu  
Mode Configuration  
End Session  
7. Select Char. Length.  
8. Select the desired character length.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
User COIN Port Config  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Baud Rate  
Parity Bit  
9600  
None  
Char. Length  
Handshaking  
Update FF  
8 Bits  
None  
Update  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
Previous Menu  
Char Length  
7 Bits  
8 Bits  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Previous Menu  
Mode Configuration  
End Session  
A-61097 May 1997  
2-27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. Select Handshaking.  
10. Select the handshaking protocol.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
User COIN Port Config  
Baud Rate  
Parity Bit  
Char. Length  
9600  
None  
8 Bits  
Handshaking  
Update FF  
None  
Update  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Previous Menu  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
Handshaking  
None  
CTS/RTS  
OI Hardware Character Set  
Save Configuration to PC  
Previous Menu  
Load Configuration from PC  
Mode Configuration  
End Session  
11. Select Update F.F.  
12. Select Fixed Field option.  
Update Fixed Field  
Don’t Update FF  
Update Fixed Field  
Previous Menu  
13. Select Previous Menu to close the User COIN Port Config window.  
2-28  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Custom Check Digit  
This option determines the check digit algorithm to be used when a  
custom check digit is calculated.  
NOTE: If a standard check digit algorithm is desired, specify the desired  
algorithm during Image Address print definitions within each mode  
setup.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Custom Check Digit.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Mode Configuration  
End Session  
The check digit is used to ensure the integrity of the Image Address.  
All parameters in the algorithm are user-definable, offering a high degree  
of flexibility.  
During filming and/or scanning, the microfilmer or scanner assigns each  
document an Image Address. The Image Address is used to compute the  
check digit. The check digit then becomes the rightmost digit of the Image  
Address (therefore, the Image Address must be defined as having a  
maximum of eleven (11) characters).  
NOTE: Because only one position is reserved, the check digit defaults to  
zero when the following conditions occur:  
·
The Lookup Table is used and the check digit is greater than  
ten (10).  
·
The Lookup Table is not used and the check digit is greater  
than nine (9).  
A-61097 May 1997  
2-29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Custom Check Digit Definition  
Custom Check Digit Formula  
[Sum of IA Digits * Attributes] + Constant 1  
Check Digit = Constant 2 -  
Divisor  
Parameter  
Attributes  
Constant 1  
Constant 2  
Divisor  
Current Value  
46231546231  
00  
00  
07  
Left/Right  
LUT Status  
Lookup Table  
Right  
No  
abcdefghijk  
Help  
Previous Menu  
The parameters displayed in the Custom Check Digit Definition window  
must be defined.  
The following section contains an explanation of each field:  
· Constant 2—A constant value in the range 0 through 99.  
· IA Digits—The digits comprising the Image Address. The Image  
Address may contain a fixed field as many as three level fields. The  
Image Address cannot exceed 11 data characters when accompanied  
by a check digit; the check digit occupies one character position.  
· Attributes—These are position weights for digits in the Image Address.  
A zero-value attribute causes the associated Image Address digit to be  
excluded from the check digit calculation. Each digit in the Image  
Address is multiplied by its attribute and summed. For example, if the  
Image Address is 1202.14.342.12 and you wish to calculate a check  
digit that excludes the fixed field (1202), the attributes (using Table 1)  
would be 00001546231.  
Table 1: Default Image Address Attributes  
C10 c9  
c8  
2
c7  
3
c6  
1
c5  
5
c4  
4
c3  
6
c2  
2
c1  
3
c0  
1
4
6
NOTE: The “c” in Table 1 refers to the character position.  
2-30  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
· Constant1—A constant value in the range 0 through 99.  
· Divisor—a constant value between 0 and 99.  
NOTE: The divisor is not used if value specified is zero (0).  
In addition to the parameters in the equation, there are other user defined  
parameters which affect check digit processing:  
· Left/Right specifier (also referred to as L/R of Decimal)—Indicates the  
location of the check digit in relation to the decimal point in the  
calculation results. This rule is applied to the ([Sum of IA Digits *  
Attributes] = Constant 1)/Divisor portion of the calculation. If Left is  
specified, the check digit is the digit immediately to the left of the  
decimal point; if Right is specified, the digit immediately to the right of  
the decimal point is the check digit. For example: If the calculation  
produces the number 123.45 and Right is the designated Left/Right  
parameter, then 4 is used.  
The following are exceptions to the Left/Right specifier rule:  
— If Constant2 is not zero, and the Left/Right specifier is Left, the  
check digit equals the difference between Constant2 and the first  
digit to the left of the decimal point. If Constant2 is zero, the first  
digit to the left of the decimal point becomes the check digit.  
— If Constant2 is not zero and the Left/Right specifier is Right, the  
check digit equals the difference between Constant2 and the first  
digit to the right of the decimal. If Constant2 is zero, the first digit to  
the right of the decimal point becomes the check digit.  
· LUT (Lookup Table) Status—If Yes, the final check digit calculated is  
used as an index into a lookup table. If No is specified, the lookup table  
is ignored.  
· Lookup table—A table of check digit values (refer to Table 2).  
Table 2: Default Lookup Table values  
C10 c9  
c8  
c
c7  
d
c6  
e
c5  
f
c4  
g
c3  
h
c2  
i
c1  
j
c0  
k
a
b
A-61097 May 1997  
2-31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sample check digit calculation #1  
Assume the following:  
Image Address  
Attributes  
=
=
=
=
=
=
=
=
123.45.678.912  
46231546231  
Constant 1  
Constant 2  
Divisor  
7
10  
11  
Left/Right  
Right  
No/off  
abcdefghijk  
LUT Status  
Lookup Table  
Then the check digit calculation would be:  
1. Set up the equation:  
Check Digit = 10 - [Calculation 1] + 7  
Calculation 1 =(2 x 1) + (1 x 3) + (9 x 2) + (8 x 6) + (7 x 4) + (6 x 5) +  
(5 x 1) + (4 x 3) + (3 x 2) + (2 x 6) + (1 x 4)  
2. Calculate the value of the fraction:  
168 + 7 = 15.91  
3. Apply the Left/Right parameter:  
15.91 = 5 if Left is specified  
15.91 = 9 if Right is specified  
In this example, 9 isused.  
4. Complete the calculation:  
10 - 9 = 1  
In this example, 1 is the check digit. The Image Address printed by the  
Document Printer would be: 123.45.678.9121  
NOTE: Because only one position is reserved, the check digit defaults to  
zero when the following conditions occur:  
·
The Lookup Table is used and the check digit is greater than  
ten (10).  
·
The Lookup Table is not used and the check digit is greater  
than nine (9).  
2-32  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sample check digit calculation #2  
Assume the following:  
Image Address  
Attributes  
=
=
=
=
=
=
=
=
123.45.678.912  
46231546231  
Constant 1  
Constant 2  
Divisor  
7
10  
11  
Left/Right  
Right  
Yes/on  
abcdefghijk  
LUT Status  
Lookup Table  
Then the check digit calculation would be:  
1. Set up the equation:  
Check Digit = 10 - [Calculation 1] + 7  
Calculation 1 =(2 x 1) + (1 x 3) + (9 x 2) + (8 x 6) + (7 x 4) + (6 x 5) +  
(5 x 1) + (4 x 3) + (3 x 2) + (2 x 6) + (1 x 4)  
2. Calculate the value of the fraction:  
168 + 7 = 15.91  
3. Apply the Left/Right parameter:  
15.91 = 5 if Left is specified  
15.91 = 9 if Right is specified  
In this example, 9 is used.  
4. Complete the calculation:  
10 - 9 = 1  
5. Apply the Lookup Table values:  
1 cross references to B  
In this example, 1 is the check digit. The Image Address printed by the  
Document Printer would be: 123.45.678.912B.  
NOTE: Because only one position is reserved, the check digit defaults to  
zero when the following conditions occur:  
·
The Lookup Table is used and the check digit is greater than  
ten (10).  
·
The Lookup Table is not used and the check digit is greater  
than nine (9).  
A-61097 May 1997  
2-33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To program a custom check digit algorithm, use the following sequence of  
steps:  
1. Select the Attributes parameter for definition.  
2. Enter the desired attribute values.  
Custom Check Digit Definition  
Custom Check Digit Formula  
[Sum of IA Digits * Attributes] + Constant 1  
Check Digit = Constant 2 -  
Divisor  
Parameter  
Attributes  
Current Value  
46231546231  
00  
Constant 1  
Constant 2  
Divisor  
Left/Right  
LUT Status  
Lookup Table  
00  
07  
Right  
No  
abcdefghijk  
Enter attribute values.  
Req’d entry 11 digits.  
Help  
46231546231  
Previous Menu  
To Change: Enter Value  
To Retain: Press Enter  
3. Select the Constant1 parameter for definition.  
4. Enter a value between 00 – 99.  
Custom Check Digit Definition  
Custom Check Digit Formula  
[Sum of IA Digits * Attributes] + Constant 1  
Check Digit = Constant 2 -  
Divisor  
Parameter  
Current Value  
Attributes  
Constant 1  
Constant 2  
Divisor  
46231546231  
00  
00  
07  
Left/Right  
LUT Status  
Lookup Table  
Right  
No  
abcdefghijk  
Enter constant #1.  
Req’d entry 2 digits.  
Help  
00  
Previous Menu  
To Change: Enter Value  
To Retain: Press Enter  
2-34  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Select the Constant2 parameter for definition.  
6. Enter a value between 00 – 99.  
Custom Check Digit Definition  
Custom Check Digit Formula  
[Sum of IA Digits * Attributes] + Constant 1  
Check Digit = Constant 2 -  
Divisor  
Parameter  
Current Value  
Attributes  
Constant 1  
46231546231  
00  
Constant 2  
Divisor  
Left/Right  
LUT Status  
Lookup Table  
00  
07  
Right  
No  
abcdefghijk  
Enter constant #2.  
Req’d entry 2 digits.  
Help  
00  
Previous Menu  
To Change: Enter Value  
To Retain: Press Enter  
7. Select the Divisor parameter for definition.  
8. Enter a value between 00 – 99.  
Custom Check Digit Definition  
Custom Check Digit Formula  
[Sum of IA Digits * Attributes] + Constant 1  
Divisor  
Check Digit = Constant 2 -  
Parameter  
Current Value  
Attributes  
Constant 1  
Constant 2  
Divisor  
46231546231  
00  
00  
07  
Left/Right  
LUT Status  
Lookup Table  
Right  
No  
abcdefghijk  
Enter divisor.  
Req’d entry 2 digits.  
Help  
07  
Previous Menu  
To Change: Enter Value  
To Retain: Press Enter  
A-61097 May 1997  
2-35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. Select the Left/Right parameter for definition.  
10. Select the digit to be used during calculation of the check digit.  
Custom Check Digit Definition  
Custom Check Digit Formula  
[Sum of IA Digits * Attributes] + Constant 1  
Check Digit = Constant 2 -  
Divisor  
Parameter  
Attributes  
Constant 1  
Constant 2  
Divisor  
Current Value  
46231546231  
00  
00  
07  
Left/Right  
LUT Status  
Lookup Table  
Right  
No  
abcdefghijk  
Start Formula at:  
Left of Decimal Pt  
Right of Decimal Pt  
Help  
Previous Menu  
Previous Menu  
11. Select the LUT Status parameter for definition.  
12. Select the desired option depending upon whether or not a lookup  
table will be used.  
Custom Check Digit Definition  
CustomCheckDigitFormula
[Sum of IA Digits * Attributes] + Constant 1  
Check Digit = Constant 2 -  
Divisor  
Parameter  
Attributes  
Constant 1  
Constant 2  
Divisor  
Current Value  
46231546231  
00  
00  
07  
Left/Right  
LUT Status  
Lookup Table  
Right  
No  
abcdefghijk  
Lookup Table Status  
Don’t use Lookup Table  
Use Lookup Table  
Help  
Previous Menu  
Previous Menu  
2-36  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13. Select the Lookup Table parameter for definition.  
14. Enter the desired lookup table values.  
Custom Check Digit Definition  
Custom Check Digit Formula  
[Sum of IA Digits * Attributes] + Constant 1  
Check Digit = Constant 2 -  
Divisor  
Parameter  
Current Value  
Attributes  
Constant 1  
46231546231  
00  
Constant 2  
Divisor  
Left/Right  
LUT Status  
Lookup Table  
00  
07  
Right  
No  
abcdefghijk  
Enter lookup table.  
Req’d entry 11 digits.  
Help  
abcdefghijk  
Previous Menu  
To Change: Enter Value  
To Retain: Press Enter  
Custom Check Digit Configuration Help  
Parameters  
Attributes  
Explanation  
These are position weights for digit in the IA. A zero-  
value attribute causes the associated IA digit to be  
excluded from the check digit calculation. Each digit in  
the IA is multiplied by its attribute and summed.  
Constant 1  
Constant 2  
Divisor  
A constant in the range 00–99.  
A constant in the range 00–99.  
A constant in the range 00–99. Not used if value is  
zero.  
Left/Right  
Indicates the location of the check digit in relation to  
the decimal point in the calculation results. If left is  
specified, the check digit is immediately to the left of  
the decimal point and vice versa.  
LUT Status  
If Yes, the final check digit calculated is used as an  
index into a lookup table. If No, the lookup table is  
ignored.  
Lookup Table  
A table of check digit values.  
A-61097 May 1997  
2-37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OI Hardware Character Set  
This option defines non-English character sets which may be used by the  
Operator Interface, Document Printers and the Film Writer. English  
characters are contained in both sets. The default OI character set is  
Anglo/Japanese.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select OI Hardware Character Set.  
2. Enter the desired printer font option.  
NOTE: The proper hardware display module must be installed.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Instructions  
Programmable Function Keys  
Date Format  
Time Format  
1. Check the character display on  
the bottom line of the OI.  
2. Select the character set based  
Alarm Tone  
on the character.  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Chracter  
Set  
ë
Anglo/Japanese  
Anglo/European  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Printer Font  
Anglo/Japanese  
Anglo/European  
Load Configuration from PC  
Mode Configuration  
Previous Menu  
End Session  
2-38  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Save Configuration to PC  
This option is used to download a configuration file from the scanner or  
microfilmer onto diskette. This is useful in creating configuration files  
which may be transported to other units (see the Load Config from PC  
option). This is also used to create backup files. This option should be  
performed any time an installation or setup change is completed.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Save Configuration to PC.  
2. Enter a file name (up to 8 characters long – no special characters  
allowed).  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Mode Configuration  
End Session  
3. Select Complete Configuration.  
Please select which machine  
variables you wish to load from  
IMAGELINK to the Laptop.  
Mode Parameters/Templates/  
Messages  
Complete Configuration  
A-61097 May 1997  
2-39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Load Configuration from PC  
This option is used to upload a configuration file from diskette to the  
scanner or microfilmer.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Load Configuration from PC.  
2. Enter a file name to upload.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Mode Configuration  
End Session  
2-40  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 Selecting the Mode Configuration Window  
This section lists the Mode Definitions for the Scanner/Microimager.  
Follow these steps to select the Mode Definition screen.  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save Configuration to PC  
Load Configuration from PC  
Mode Configuration  
End Session  
1. Select Mode Configuration.  
The following window will be displayed:  
Mode Configuration  
Define Mode 1  
Define Mode 2  
Define Mode 3  
Define Mode 4  
Define Mode 5  
Define Mode 6  
Define Mode 7  
Define Mode 8  
Define Mode 9  
Define Mode 10  
Define Mode 11  
Define Mode 12  
Define Mode 13  
Define Mode 14  
Define Mode 15  
Define Mode 16  
Define Mode 17  
Define Mode 18  
Mode to Mode Copy  
End Session  
Previous Menu  
A-61097 May 1997  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Select a mode to be defined.  
The Mode Configuration window will be displayed, with the Mode  
Number you selected for definition displayed at the top.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
MODE 10 Mode Name  
Ftswitch Pressed  
Undef  
3 Lvl  
Supprs  
4233  
Index Format  
IA Display Format  
IA Field Widths  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Off  
Off  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Lvl 2  
On  
Duplex  
?????  
1 Roll  
Film Mode  
Reduction Ratio  
# of Cassettes  
Confirmation Tone  
OCR Status  
COIN User Channel  
N N N  
Off  
On  
Comic  
Off  
Off  
Film Writer  
Image Mgmt Code  
Length Monitor  
Printer Control  
Primary DP-1  
Secondary DP-1  
Disply  
Off  
Off  
Off  
Xport  
Off  
Skew Monitor  
Check Stacker  
Endorser  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Off  
Off  
No Sav  
Not Used  
Film Definition  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
This window provides access to all of the mode definition parameters.  
NOTE: The following options are not available on scanners 900, 923, and  
9500:  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Film Writer  
Image Mgmt Code  
Film Definition = NoF  
3-2  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mode Definitions  
The following section lists the items on the Mode Configuration Menu that  
may be selected for definition. Unavailable machine types are indicated by  
hollow boxes.  
Mode Name  
This option defines the mode name.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Mode Name.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Undef  
Undef  
3 Lvl  
Index Format  
Supprs  
4233  
2112  
IA Display Format  
IA Field Widths  
Level Rules  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Off  
Off  
Off  
None  
Auto  
Duplex  
Batching  
AEC Mode  
Film Mode  
Patch Definition  
Bar Code  
Confirmation Tone  
Lvl 2  
Off  
N N N  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Length Monitor  
Skew Monitor  
Check Stacker  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Off  
Off  
Off  
Off  
Endorser  
Not Used  
Mode Overrides  
Film Definition  
No Sav  
F
Enter Mode Name  
MODE10  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Enter a ten (10) character (maximum) alphanumeric name.  
A-61097 May 1997  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index Format  
This mode defines the index format used by the application mode. Refer  
to Description 3: Index Formats for a description of the index formats.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
When using a Microimager 70 without the Advanced Function Module  
installed, only the index format for Mode 8 and Mode 9 may be defined;  
the index format is predefined and unalterable in Mode 1 through Mode 7.  
The predefined values are:  
· Mode 1—Single Level  
· Mode 2—Two Level Offset  
· Mode 3—Two Level  
· Mode 4—Three Level Offset  
· Mode 5—Three Level  
· Mode 6—Two Level  
· Mode 7—Two Level Offset  
When using a Microimager with the Advanced Function Module installed,  
Scanner 900, Scanner 923, Scanner 9500, or Scanner/Microimager 990,  
the index format for all modes may be defined.  
1. Select Index Format.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Index Format  
Single Level  
Two Level  
Three Level  
Two Level Offset  
Three Level Offset  
MODE 10 Mode Name  
Ftswitch Pressed  
Undef  
Undef  
Off  
Off  
Off  
3 Lvl  
Supprs  
4233  
2112  
None  
Auto  
Index Format  
IA Display Format  
IA Field Widths  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Level Rules  
Batching  
AEC Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Lvl 2  
Off  
Previous Menu  
Duplex  
?????  
1 Roll  
Film Mode  
Reduction Ratio  
# of Cassettes  
Confirmation Tone  
OCR Status  
COIN User Channel  
N N N  
Off  
On  
Comic  
Off  
Off  
Film Writer  
Image Mgmt Code  
Length Monitor  
Printer Control  
Primary DP-1  
Secondary DP-1  
Disply  
Off  
Off  
Off  
Xport  
Off  
Skew Monitor  
Check Stacker  
Endorser  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Off  
Off  
No Sav  
Not Used  
Film Definition  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Select the desired index format option.  
NOTE: If you intend to link the current mode with another mode, the index  
format chosen for both modes must be the same.  
3-4  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Description 3: Index Formats  
There are five Index Format options available:  
Single Level  
IA 1  
IA 2  
IA 3  
IA 4  
(Level 1)  
(Level 1)  
(Level 1)  
(Level 1)  
Whenever a small image mark is placed next to a document and/or a document is assigned Level 1, the Image  
Address field associated with Level 1 (Field A) is incremented.  
Two Level  
IA 1.0  
IA 1.1  
IA 1.2  
IA 2.0  
(Level 2)  
(Level 1)  
(Level 1)  
(Level 2)  
Whenever a medium image mark is placed next to a document and/or the document is assigned Level 2, the  
Image Address field associated with Level 2 (Field B) is incremented and the field associated with Level 1  
(Field A) is set to zero.  
Whenever a small image mark is placed next to a document and/or a document is assigned Level 1, the Image  
Address field associated with Level 2 (Field B) is unchanged and the field associated with Level 1 (Field A) is  
incremented.  
Two Level Offset  
IA 1  
IA 1  
IA 1  
IA 2  
(Level 2)  
(Level 1)  
(Level 1)  
(Level 2)  
Whenever a medium image mark is placed next to a document and/or a document is assigned Level 2, the  
Image Address field associated with Level 2 (Field B) is incremented.  
Whenever a small image mark is placed next to a document and/or a document is assigned Level 1, the Image  
Address is unchanged.  
A-61097 May 1997  
3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Description 3: Index Formats (continued)  
Three Level  
IA 1.0.0  
IA 1.1.0  
IA 1.1.1  
IA 2.0.0  
(Level 3)  
(Level 2)  
(Level 1)  
(Level 3)  
Whenever a large image mark is placed next to a document and/or a document is assigned Level 3, the Image  
Address field associated with Level 3 (Field C) is incremented and the fields associated with Level 2 (Field B)  
and Level 1 (Field A) are set to zero.  
Whenever a medium image mark is placed next to a document and/or a document is assigned Level 2, the  
Image Address Field associated with Level 3 (Field C) is unchanged, the field associated with Level 2 (Field B)  
is incremented, and the field associated with Level 1 (Field A) is set to zero.  
Whenever a small image mark is placed next to a document and/or a document is assigned Level 1, the Image  
Address fields associated with Level 3 (Field C) and Level 2 (Field B) are unchanged, and the field associated  
with Level 1 (Field A) is incremented.  
Three Level Offset  
IA 1.0  
IA 1.1  
IA 1.1  
IA 2.0  
(Level 3)  
(Level 2)  
(Level 1)  
(Level 3)  
Whenever a large image mark is placed next to a document and/or a document is assigned Level 3, the Image  
Address field associated with Level 3 (Field C) is incremented and the field associated with Level 2 (Field B) is  
set to zero.  
Whenever a medium image mark is placed next to a document and/or a document is assigned Level 2, the  
Image Address field associated with Level 3 (Field C) is unchanged, and the field associated with Level 2 (Field  
B) is incremented.  
Whenever a small image mark is placed next to a document and/or a document is assigned Level 1, the Image  
Address is unchanged.  
3-6  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Image Address Display Format  
This mode defines the format of the Image Address display which appears  
on the control panel. The default is Suppress.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select IA Display Format.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
MODE 10 Mode Name  
Ftswitch Pressed  
Undef  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Off  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Off  
Off  
Lvl 2  
Auto  
Duplex  
?????  
AEC Mode  
Film Mode  
Reduction Ratio  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
1 Roll  
Comic  
# of Cassettes  
Film Writer  
COIN User Channel  
Printer Control  
On  
Disply  
Examples of Formats  
Display: 001.002.003.004  
Off  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Off  
Off  
Off  
Compress:001.2.3.4  
Suppress: 001. 002.003.004  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
IA Display Format  
Display Leading Zeros  
Compress Leading Zeros  
Suppress Leading Zeros  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired format option.  
A-61097 May 1997  
3-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Image Address Field Widths  
This mode defines the Image Address field widths.  
Refer to Description 4: Image Address Fields for a description of proper  
field definitions.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
When using a Microimager 70 without the Advanced Function Module  
installed, only the Image Address field widths for Mode 8 and Mode 9 may  
be defined; the field widths are predefined and unalterable in Mode 1  
through Mode 7. The predefined values are:  
· Mode 1 – Fixed Field (6)  
Field C – Level 3 (0)  
Field B – Level 2 (0)  
Field A – Level 1 (6)  
· Mode 2 – Fixed Field (6)  
Field C – Level 3 (0)  
Field B – Level 2 (6)  
Field A – Level 1 (0)  
· Mode 3 – Fixed Field (6)  
Field C – Level 3 (0)  
Field B – Level 2 (3)  
Field A – Level 1 (3)  
· Mode 4 – Fixed Field (6)  
Field C – Level 3 (3)  
Field B – Level 2 (3)  
Field A – Level 1 (0)  
· Mode 5 – Fixed Field (4)  
Field C – Level 3 (2)  
Field B – Level 2 (3)  
Field A – Level 1 (3)  
· Mode 6 – Fixed Field (6)  
Field C – Level 3 (0)  
Field B – Level 2 (4)  
Field A – Level 1 (2)  
· Mode 7 – Fixed Field (6)  
Field C – Level 3 (0)  
Field B – Level 2 (6)  
Field A – Level 1 (0)  
When using a Microimager with the Advanced Function Module installed,  
Scanner 900, Scanner 923, Scanner 9500, or Scanner/Microimager 990,  
the Image Address Field widths for all modes may be defined.  
NOTE: A field width definition for all fields (Field A – Level 1, Field B –  
Level 2, Field C – Level 3, and Fixed Field ) must be specified.  
3-8  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Select IA Field Widths.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Field Num  
Fixed Field  
Field A  
Field B  
Field C  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
Off  
Off  
3 Lvl  
Supprs  
4233  
2112  
None  
Index Format  
IA Display Format  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Previous Menu  
Lvl 2  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Select the field to be defined.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Field Num  
Fixed Field  
Field A  
Field B  
Field C  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
IA Field Widths  
Supprs  
4233  
Off  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Lvl 2  
Off  
Previous Menu  
Duplex  
Confirmation Tone  
N N N  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Off  
Off  
Off  
No Sav  
Not Used  
Film Definition  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Enter Field Width  
0 1 2 3 4 5 6 7 8 9  
3. Select the desired field width for the specified field.  
NOTE: If you intend to link the current mode with another mode, the field  
width definitions for both modes must be the same.  
If you change the field widths a message appears:  
To avoid E205 errors at powerup, first save mode programming,  
then enter a new IA for mode.  
4. Press Enter.  
A-61097 May 1997  
3-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Description 4: Image Address Fields  
An Image Address is a unique identifier assigned to each individual document by the Microimager 70, Scanner  
900, Scanner 923, Scanner 9500, or Scanner/Microimager 990.  
An Image Address may contain up to 15 characters, consisting of a maximum of 12 digits  
Description 4: Image Address Fields.  
An Image Address is a unique identifier assigned to each individual document by the Microimager 70, Scanner  
900, Scanner 923, Scanner 9500, or Scanner/Microimager 990.  
An Image Address may contain up to 15 characters, consisting of a maximum of 12 digits and a maximum of 3  
delimiters.  
Four fields must be defined:  
Field A represents Level 1. Its value is incremented when a small image mark is placed next to a document  
and/or a document is assigned Level 1.  
Field B represents Level 2. Its value is incremented when a medium image mark is placed next to a document  
and/or a document is assigned Level 2.  
Field C represents Level 3. Its value is incremented when a large image mark is placed next to a document  
and/or a document is assigned Level 3.  
Fixed Field contains fixed information; typically, the date.  
Example:  
0 3 0 1 . 0 2 . 0 0 1 . 0 0 0 where: Field A contains 000  
Field B contains 001  
Field C contains 02  
Fixed Field contains 0301  
The Image Address field lengths are dependent upon the Index Format chosen earlier:  
· Single Level  
Field A is defined as having a field length greater than zero (1 – 9)  
Field B is defined as having a field length of zero (0)  
Field C is defined as having a field length of zero (0)  
Fixed Field may be defined, if desired (0 – 9)  
3-10  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Description 4: Image Address Fields (continued)  
· Two Level  
Field A is defined as having a field length greater than zero (1 – 9)  
Field B is defined as having a field length greater than zero (1 – 9)  
Field C is defined as having a field length of zero (0)  
Fixed Field may be defined, if desired (0 – 9)  
· Two Level Offset  
Field A is defined as having a field length of zero (0)  
Field B is defined as having a field length greater than zero (1 – 9)  
Field C is defined as having a field length of zero (0)  
Fixed Field may be defined, if desired (0 – 9)  
· Three Level  
Field A is defined as having a field length greater than zero (1 –9)  
Field B is defined as having a field length greater than zero (1 – 9)  
Field C is defined as having a field length greater than zero (1 – 9)  
Fixed Field may be defined, if desired (0 – 9)  
· Three Level Offset  
Field A is defined as having a field length greater than zero (1 –9)  
Field B is defined as having a field length greater than zero (1 – 9)  
Field C is defined as having a field length greater than zero (1 – 9)  
Fixed Field may be defined, if desired (0 – 9)  
A-61097 May 1997  
3-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Level Rules  
This mode defines the level of a document based upon the level of the  
previous document. These definitions are used as defaults when the  
document level is not determined by another method (i.e., Footswitch,  
P-Key, Level Key, etc.)  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
When using a Microimager 70 without the Advanced Function Module  
installed, only the level rules for Mode 8 and Mode 9 may be defined; the  
level rules are predefined and unalterable in Mode 1 – Mode 7. The  
predefined values are:  
· Mode 1 – Level 0 followed by Level 1  
Level 1 followed by Level 1  
Level 2 followed by no level  
Level 3 followed by no level  
· Mode 2 – Level 0 followed by Level 2  
Level 1 followed by Level 1  
Level 2 followed by Level 2  
Level 3 followed by no level  
· Mode 3 – Level 0 followed by Level 2  
Level 1 followed by Level 1  
Level 2 followed by Level 2  
Level 3 followed by no level  
· Mode 4 – Level 0 followed by Level 3  
Level 1 followed by Level 1  
Level 2 followed by Level 2  
Level 3 followed by Level 2  
· Mode 5 – Level 0 followed by Level 2  
Level 1 followed by Level 1  
Level 2 followed by Level 1  
Level 3 followed by Level 2  
· Mode 6 – Level 0 followed by Level 2  
Level 1 followed by Level 2  
Level 2 followed by no level  
Level 3 followed by no level  
· Mode 7 – Level 0 followed by Level 2  
Level 1 followed by Level 2  
Level 2 followed by Level 2  
Level 3 followed by no level  
When using a Microimager with the Advanced Function Module installed,  
Scanner 900, Scanner 923, Scanner 9500, or Scanner/Microimager 990,  
the level rules for all modes may be defined.  
3-12  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Select Level Rules.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Field  
Level 0  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Undef  
Undef  
Off  
Off  
Off  
Level 1  
Level 2  
Level 3  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Previous Menu  
Lvl 2  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Select the level to be assigned a following level.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Field  
Level 0  
Level 1  
Level 2  
Level 3  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
IA Field Widths  
Supprs  
4233  
Off  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Lvl 2  
Off  
Previous Menu  
Duplex  
Confirmation Tone  
N N N  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Follow Field #  
Level 0  
Level 1  
Level 2  
Not Used  
Level 3  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
3. Select the level to follow the specified level.  
A-61097 May 1997  
3-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Batching  
This mode defines the number of documents of a specified level to  
process prior to performing a predefined action.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select Batching.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Batching  
Batch Level  
Batch Value  
Start of Batch Function  
End of Batch Function  
MODE 10 Mode Name Ftswitch Pressed  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
IA Field Widths  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Supprs  
4233  
Off  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Lvl 2  
Off  
Previous Menu  
Duplex  
Confirmation Tone  
N N N  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Not Used  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Batch Level  
This mode defines the level of the documents to be counted. The default  
value is None.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Batch Level.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Batching  
Batch Level  
Batch Value  
Start of Batch Function  
End of Batch Function  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
IA Field Widths  
Supprs  
4233  
Off  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Lvl 2  
Off  
Previous Menu  
Duplex  
Confirmation Tone  
N N N  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Batch Field  
Level 1  
Level 2  
Level 3  
Not Used  
None  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired batch level.  
NOTE: If you select None, you can’t set Batch Value.  
3-14  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Batch Value  
Defines the number of documents to be counted prior to performing a  
predefined action. The default value is 99.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Batch Value.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Batching  
Batch Level  
Batch Value  
Start of Batch Function  
End of Batch Function  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
IA Field Widths  
Supprs  
4233  
Off  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Lvl 2  
Off  
Previous Menu  
Duplex  
Confirmation Tone  
N N N  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Not Used  
Enter Batch Value  
99  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Range: 1-99  
2. Enter the number of documents to be counted as a batch.  
The value entered should be between 1 and the maximum image  
address size for the field (or 9999, whichever is less).  
Use the following information to determine the maximum number  
allowed:  
— If the length of the level field is 1, the maximum batching value is 9.  
— If the length of the level field is 2, the maximum batching value is  
99.  
— If the length of the level field is 3, the maximum batching value is  
999.  
— If the length of the level field is 4, the maximum batching value is  
9999.  
— If the length of the level field is 5 – 9, the maximum batching value  
is 99999.  
A-61097 May 1997  
3-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Start of Batch Function  
This mode defines the action(s) to be taken prior to processing the  
document in the batch. The default value is Nothing.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Start of Batch Function.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Batching  
Batch Level  
Batch Value  
Start of Batch Function  
End of Batch Function  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
IA Field Widths  
Supprs  
4233  
Off  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Lvl 2  
Off  
Previous Menu  
Duplex  
Confirmation Tone  
N N N  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Not Used  
Start-of-Batch Function  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Enter the function(s) to be performed prior to batch processing. Valid  
Start-of-Batch functions are:  
–f94  
–f95  
–f96  
go to Level 1  
go to Level 2  
go to Level 3  
3-16  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
End of Batch Function  
This mode defines the action(s) to be taken after processing the document  
in the batch. The default value is f98, Stop.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select End of Batch Function.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Batching  
Batch Level  
Batch Value  
Start of Batch Function  
End of Batch Function  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Undef  
Undef  
Off  
Off  
Off  
3 Lvl  
Index Format  
Supprs  
4233  
2112  
IA Display Format  
IA Field Widths  
Level Rules  
Previous Menu  
None  
Auto  
Duplex  
Batching  
AEC Mode  
Film Mode  
Patch Definition  
Bar Code  
Confirmation Tone  
Lvl 2  
Off  
N N N  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Length Monitor  
Skew Monitor  
Check Stacker  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Off  
Off  
Off  
Off  
Endorser  
Not Used  
Mode Overrides  
Film Definition  
No Sav  
F
End-of-Batch Function  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Enter the function(s) to be performed after batch processing.  
–f94  
–f95  
–f96  
–f98  
go to Level 1  
go to Level 2  
go to Level 3  
Stop  
A-61097 May 1997  
3-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AEC Mode  
This mode enables or disables Automatic Exposure Control. Fixed Mode  
disables Automatic Exposure Control. Auto Mode enables Automatic  
Exposure Control. The default value is Auto Mode.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select AEC Mode.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
AECStatus  
Fixed Mode  
Auto Mode  
MODE 10 Mode Name Ftswitch Pressed  
Undef  
Undef  
Off  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
Ftswitch Released  
Ftswitch Cnf Tone  
Previous Menu  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Off  
Off  
Lvl 2  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Select the desired AEC mode.  
NOTE: AEC mode is not available on the scanners.  
3-18  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Film Mode  
This mode defines the orientation of documents on film. Refer to  
Description 5: Film Modes for a description of the available film modes.  
The default value is Duplex.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select Film Mode.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
AECStatus  
Simplex Mode  
Duplex Mode  
Duo Mode  
MODE 10 Mode Name Ftswitch Pressed  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
Ftswitch Released  
Ftswitch Cnf Tone  
Supprs  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Off  
Off  
Lvl 2  
Previous Menu  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Simplx  
Duo  
Duplex  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
f
b
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
50X  
40X  
24X  
50X  
40X  
50X  
40X  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Select the desired film mode.  
NOTE: If you intend to link the current mode with another mode, the film  
mode chosen for both modes must be compatible. Simplex mode  
is compatible with either simplex mode or duplex mode. Duplex  
mode is compatible with either simplex mode or duplex mode.  
Duo mode is compatible only with duo mode.  
NOTE: Film mode is not available on the scanners.  
A-61097 May 1997  
3-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
· Simplex Mode  
Simplex format allows one image to be exposed across the film width. A  
24:1 reduction ratio is used for this format.  
· Duplex Mode  
Duplex format allows front and back images of the same document to  
be exposed (at the same time) across the film width. A 40:1 or 50:1  
reduction ratio is used for this format.  
· Duo Mode  
Duo format allows documents to be filmed across one-half of the film  
width, with additional documents filmed on the adjacent side. A 40:1 or  
50:1 reduction ratio is used for this format.  
3-20  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reduction Ratio  
This mode defines the level of magnification. The default value is Don’t  
Care.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Reduction Ratio.  
Mode Number: 10  
MMooddeeNNaammee:: MMOODDEE1100  
Mode Configuration  
Reduction Ratio  
Don't Care  
24x  
40x  
50x  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
Off  
Off  
3 Lvl  
Supprs  
4233  
2112  
None  
Index Format  
IA Display Format  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Previous Menu  
Lvl 2  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Select the desired reduction ratio.  
Use the following information to determine the reduction allowed  
based upon the Film Mode selected:  
— If the film mode is Simplex, you may select 50X, 40X, or 24X.  
— If the film mode is Duplex, you may select 50X or 40X.  
— If the film mode is Duo, you may select 50X or 40X.  
NOTE: This selection is not available on the scanners.  
A-61097 May 1997  
3-21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Number of Cassettes  
This mode defines the minimum number of cassettes that must be  
installed during filming. If Two Cassettes is chosen, you must always use  
two cassettes. If One Cassette is chosen, you may use one or two  
cassettes. The default value is One Cassette.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select # of Cassettes.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
CassettesReq'd  
Two Cassettes  
One Cassette  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
Supprs  
Previous Menu  
4233  
2112  
None  
Auto  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Off  
Lvl 2  
Off  
AEC Mode  
Duplex  
?????  
1 Roll  
Film Mode  
Reduction Ratio  
# of Cassettes  
Confirmation Tone  
OCR Status  
COIN User Channel  
N N N  
Off  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Select the minimum number of cassettes required.  
NOTE: This selection is not available on the scanners.  
3-22  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Film Writer  
NOTE: The Film Writing Module must be installed.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select Film Writer.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Advanced Film Writer  
Character Orientation  
Image Addr Print Format  
Same Sequence per Level  
Print Sequence - Level 0  
Print Sequence - Level 1  
MODE 10 Mode Name Ftswitch Pressed  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
3 Lvl  
Supprs  
4233  
2112  
None  
Index Format  
IA Display Format  
Ftswitch Released  
Ftswitch Cnf Tone  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Print Sequence - Level 2  
Print Sequence - Level 3  
Auto  
AEC Mode  
Bar Code  
Duplex  
?????  
1 Roll  
Film Mode  
Reduction Ratio  
# of Cassettes  
Confirmation Tone  
OCR Status  
COIN User Channel  
N N N  
Off  
On  
Previous Menu  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
NOTE: This selection is not available on the scanners.  
A-61097 May 1997  
3-23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Character Orientation  
This mode defines the orientation of the information printed by the film  
writer. The default is Comic.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Character Orientation.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Advanced Film Writer  
Character Orientation  
Image Addr Print Format  
Same Sequence per Level  
Print Sequence - Level 0  
Print Sequence - Level 1  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
3 Lvl  
Supprs  
4233  
2112  
None  
Index Format  
IA Display Format  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Print Sequence - Level 2  
Print Sequence - Level 3  
Auto  
AEC Mode  
Bar Code  
Duplex  
?????  
1 Roll  
Film Mode  
Reduction Ratio  
# of Cassettes  
Confirmation Tone  
OCR Status  
COIN User Channel  
N N N  
Off  
On  
Previous Menu  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Orientation  
Comic  
Cine  
Comic 180  
Cine 180  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired orientation.  
3-24  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Image Address Print Format  
This mode defines the format of the Image Address printed on film.  
The default is Compress.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Image Addr Print Format.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Advanced Film Writer  
Character Orientation  
Image Addr Print Format  
Same Sequence per Level  
Print Sequence - Level 0  
Print Sequence - Level 1  
Print Sequence - Level 2  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
3 Lvl  
Supprs  
4233  
2112  
None  
Auto  
Index Format  
IA Display Format  
IA Field Widths  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Print Sequence - Level 3  
Duplex  
Confirmation Tone  
Previous Menu  
?????  
1 Roll  
Comic  
Off  
Off  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
No Sav  
F
COIN User Channel  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Examples of Formats  
Display: 001.002.003.004  
Compress:001.2.3.4  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Suppress: 001.002.003.004  
Xport  
Off  
Film Writer IA Format  
Display Leading Zeros  
Compress Leading Zeros  
Suppress Leading Zeros  
Not Used  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired format option.  
A-61097 May 1997  
3-25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Write Definitions  
This mode defines the information printed on film next to each document,  
based upon the document level. The default value for all levels is  
<FF/IA-All Del>.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
When using a Microimager 70 without the Advanced Function Module  
installed, a limited number of print items are available. The available print  
items are:  
· Full Image Address  
· Indexed Fields Only  
· Nothing Printed  
When using a Microimager 70 with the Advanced Function Module  
installed, or Scanner/Microimager 990, all print items may be used.  
If the same information is to be printed next to documents of all levels:  
1. Select Same Sequence per Level.  
FAN Write Sequence  
Full Image Address  
Current Print Sequence Display Values  
Indexed Fields Only  
Current Field Level  
Spaces between Items  
Current Day  
<Full IA> <2 Sp> <Date> <2Sp> <Time>  
Default is <FF/IA - All Del>  
Current Date  
Current Time  
Document Counter  
Message 1  
New Print Sequence Display Values  
Message 2  
Message 3  
Message 4  
Message 5  
Message 6  
Message 7  
Message 8  
Message 9  
Nothing Printed  
Previous Menu  
2. Select the item(s) to be printed.  
NOTE: If the definition exceeds the thirty-eight (38) character limit, the  
first thirty-eight (38) characters will be printed on film next to each  
document and the remainder of the information will be truncated.  
New information will appear in the New Print Sequence Display  
Values box. When you press Enter, the print sequence will appear  
in the upper box.  
3-26  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If different information is to be printed next to documents of different  
levels:  
1. Select Print Sequence – Level # for the desired level.  
FAN Write Sequence  
Current Print Sequence Display Values  
Full Image Address  
Indexed Fields Only  
Current Field Level  
Spaces between Items  
Current Day  
<Full IA> <2 Sp> <Date> <2Sp> <Time>  
Default is <FF/IA - All Del>  
Current Date  
Current Time  
Document Counter  
New Print Sequence Display Values  
Message 1  
Message 2  
Message 3  
Message 4  
Message 5  
Message 6  
Message 7  
Message 8  
Message 9  
Nothing Printed  
Previous Menu  
2. Select the item(s) to be printed.  
NOTE: If the definition exceeds the thirty-eight (38) character limit, the  
first thirty-eight (38) characters will be printed on film next to each  
document and the remainder of the information will be truncated.  
A-61097 May 1997  
3-27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Image Management Code  
NOTE: The Film Writing Module must be installed.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select Image Mgmt Code.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Image Management Code  
Status  
IMT Search Prg Number  
Magnification  
Splice Definition  
Image Mark Sizes  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
3 Lvl  
Supprs  
4233  
2112  
None  
Index Format  
IA Display Format  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Image Polarity  
Duplex Front Location  
Film Image Orientation  
Image Offset  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Duplex  
?????  
1 Roll  
COIN User Channel  
Previous Menu  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
NOTE: This selection is not available on the scanners.  
3-28  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Status  
This mode enables or disables the use of IMC options. The default value  
is Off or Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select Status.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Image Management Code  
Status  
IMT Search Prg Number  
Magnification  
Splice Definition  
Image Mark Sizes  
MODE 10 Mode Name Ftswitch Pressed  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
3 Lvl  
Supprs  
4233  
2112  
None  
Index Format  
IA Display Format  
Ftswitch Released  
Ftswitch Cnf Tone  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Image Polarity  
Duplex Front Location  
Film Image Orientation  
Image Offset  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Duplex  
?????  
1 Roll  
COIN User Channel  
Previous Menu  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
IMCStatus  
Off or Diabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired status.  
NOTE: If the status is defined as Off or Disabled, definitions for the  
remaining IMC options will be ignored.  
A-61097 May 1997  
3-29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMT Search Program Number  
This mode defines the IMT search program number. The default value is  
00.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select IMT Search Prg Number.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Image Management Code  
Status  
IMT Search Prg Number  
Magnification  
Splice Definition  
Image Mark Sizes  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
3 Lvl  
Supprs  
4233  
2112  
None  
Index Format  
IA Display Format  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Image Polarity  
Duplex Front Location  
Film Image Orientation  
Image Offset  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Duplex  
?????  
1 Roll  
COIN User Channel  
Previous Menu  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Enter Program Number  
00  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Range: 0 - 70  
2. Enter a two-digit program number.  
3-30  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Magnification  
This mode defines for the KODAK IMAGELINK™ Digital Workstation (with  
Zoom Lens Accessory) the desired level of magnification. The default  
value is 20.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Magnification.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Image Management Code  
Status  
IMT Search Prg Number  
Magnification  
Splice Definition  
Image Mark Sizes  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
3 Lvl  
Supprs  
4233  
2112  
None  
Index Format  
IA Display Format  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Image Polarity  
Duplex Front Location  
Film Image Orientation  
Image Offset  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Duplex  
?????  
1 Roll  
COIN User Channel  
Previous Menu  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Enter Magnification  
20  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Range: 0 or 20 - 80  
Use 0 for RIM 2000 Code  
2. Enter the desired magnification level within the range 0 or 20 – 80.  
A-61097 May 1997  
3-31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Splice Definition  
This mode defines the desired action when a splice is detected. The  
default value is Ignore.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Splice Definition.  
Select any of the Sort Criteria and the following screen appears:  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Image Management Code  
Status  
IMT Search Prg Number  
Magnification  
Splice Definition  
Image Mark Sizes  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
3 Lvl  
Supprs  
4233  
2112  
None  
Index Format  
IA Display Format  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Image Polarity  
Duplex Front Location  
Film Image Orientation  
Image Offset  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Duplex  
?????  
1 Roll  
COIN User Channel  
Previous Menu  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Splice  
Ignore  
Level 1  
Level 2  
Level 3  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired action.  
3-32  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Image Mark Sizes  
This mode defines the image mark sizes used (small, medium, and large).  
The default value is Kodak Standard.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Image Mark Sizes.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Image Management Code  
Status  
IMT Search Prg Number  
Magnification  
Splice Definition  
Image Mark Sizes  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
3 Lvl  
Supprs  
4233  
2112  
None  
Index Format  
IA Display Format  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Image Polarity  
Duplex Front Location  
Film Image Orientation  
Image Offset  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Duplex  
?????  
1 Roll  
COIN User Channel  
Previous Menu  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Image Mark Size  
Custom Setup  
Kodak Standard  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired Image Mark Size option.  
Custom Setup should only be selected if the Kodak Field Engineer  
has defined the customer image mark sizes (small, medium, and  
large).  
A-61097 May 1997  
3-33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Image Polarity  
This mode defines the polarity of the image marks relative to the polarity  
of the document images. The default value is Same as Image Mark.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Image Polarity.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Image Management Code  
Status  
IMT Search Prg Number  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
3 Lvl  
Supprs  
4233  
2112  
None  
Auto  
Index Format  
IA Display Format  
IA Field Widths  
Magnification  
Splice Definition  
Image Mark Sizes  
Image Polarity  
Duplex Front Location  
Film Image Orientation  
Image Offset  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Duplex  
Confirmation Tone  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
COIN User Channel  
Printer Control  
Primary DP-1  
Previous Menu  
Disply  
Off  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Not Used  
ImagePolarity  
Opposite of Image Mark  
Same as Image Mark  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired polarity option.  
NOTE: Select Opposite of Image Mark only when splicing the Image  
Management Code onto the leading edge of film on which the  
image mark polarity is opposite the document image polarity.  
3-34  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Duplex Front Location  
The mode defines for the KODAK IMAGELINK™ Digital Workstation  
where the front side image is located. The default value is Same as IM  
Channel.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Duplex Front Location.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Image Management Code  
Status  
IMT Search Prg Number  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
3 Lvl  
Supprs  
4233  
2112  
None  
Auto  
Index Format  
IA Display Format  
IA Field Widths  
Magnification  
Splice Definition  
Image Mark Sizes  
Image Polarity  
Duplex Front Location  
Film Image Orientation  
Image Offset  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Duplex  
Confirmation Tone  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
COIN User Channel  
Printer Control  
Primary DP-1  
Previous Menu  
Disply  
Off  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Not Used  
Duplex Front Location  
Opposite of IM Channel  
Same as IM Channel  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired front side image location.  
A-61097 May 1997  
3-35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Film Image Orientation  
The mode defines where the top of the image is located for the  
KODAK IMAGELINK™ Digital Workstation. The default value is Leading  
Edge Up.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Film Image Orientation.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Image Management Code  
Status  
IMT Search Prg Number  
Magnification  
Splice Definition  
Image Mark Sizes  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
3 Lvl  
Supprs  
4233  
2112  
None  
Index Format  
IA Display Format  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Image Polarity  
Duplex Front Location  
Film Image Orientation  
Image Offset  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Duplex  
?????  
1 Roll  
COIN User Channel  
Previous Menu  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
ImageOrientation  
Leading Edge Down  
Leading Edge Up  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired image orientation.  
3-36  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Image Offset  
This mode defines the position of the image marks relative to the leading  
edge of the document. The default value is 0.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Image Offset.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Image Management Code  
Status  
IMT Search Prg Number  
Magnification  
Splice Definition  
Image Mark Sizes  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
3 Lvl  
Supprs  
4233  
2112  
None  
Index Format  
IA Display Format  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Image Polarity  
Duplex Front Location  
Film Image Orientation  
Image Offset  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Duplex  
?????  
1 Roll  
COIN User Channel  
Previous Menu  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Enter Image Offset  
000  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Range: 0 - 127  
2. Enter a number within the range 0 - 127.  
A-61097 May 1997  
3-37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Length Monitor  
NOTE: The Advanced Document Controller must be installed.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Length Monitor.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Length Monitor  
Status  
Max Document Length  
Min Document Length  
Length Err Response  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
IA Field Widths  
Supprs  
4233  
Off  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Lvl 2  
Off  
Previous Menu  
Duplex  
Confirmation Tone  
N N N  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Not Used  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
3-38  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Status  
This mode enables or disables length monitoring. The default value is Off  
or Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select Status.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Length Monitor  
Status  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Undef  
Undef  
Off  
Off  
Off  
Max Document Length  
Min Document Length  
Length Err Response  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Previous Menu  
Lvl 2  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
LengthCheck  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired status.  
NOTE: If Off or Disabled is selected, definitions for the remaining options  
will be ignored.  
A-61097 May 1997  
3-39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maximum Document Length  
This mode defines the maximum document length accepted. The default  
value is 13.000 inches/325 mm.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Max Document Length.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Length Monitor  
Status  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Undef  
Undef  
Off  
Off  
Off  
Max Document Length  
Min Document Length  
Length Err Response  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Previous Menu  
Lvl 2  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Enter Max. Doc. Length  
Range: 2.50...75.000  
0013.00 inches  
0330.20 metric  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Enter the maximum document length within the allowable range for  
your machine type:  
— Microimager 70—2.5 to 75 inches or 63 to 1905 mm.  
— Scanner 900—2.5 to 20 inches or 63 to 508.00 mm.  
— Scanner 923—2.5 to 20 inches or 63 to 508.00 mm.  
— Scanner 9500—2.5 to 30 inches or 63 to 762 mm.  
— Scanner/Microimager 990—2.5 to 2.0 inches or 63.50  
to 508.00 mm.  
3-40  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Minimum Document Length  
This mode defines the minimum document length accepted. The default  
value is 02.500 inches/63 mm.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Min Document Length.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Length Monitor  
Status  
Max Document Length  
Min Document Length  
Length Err Response  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
IA Field Widths  
Supprs  
4233  
Off  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Lvl 2  
Off  
Previous Menu  
Duplex  
Confirmation Tone  
N N N  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Enter Min. Doc. Length  
Range: 2.500...13.00  
Not Used  
0002.500 inches  
0063.499 metric  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Enter the minimum document length within the range 2.5 to 13 inches  
or 63.50 to 330.20 mm.  
A-61097 May 1997  
3-41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Length Error Response  
This mode defines the action taken if a document is smaller than the  
minimum length specified or larger than the maximum length specified.  
The default value is Display and Beep.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Length Err Response.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Length Monitor  
Status  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Undef  
Undef  
Off  
Off  
Off  
Max Document Length  
Min Document Length  
Length Err Response  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Previous Menu  
Lvl 2  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Len Chk Error Response  
Display  
Display and Beep  
Stop and Display  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired error response action.  
3-42  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Skew Monitor  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
NOTE: The Advanced Document Controller must be installed.  
1. Select Skew Monitor.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Skew Monitor  
Skew Detect Status  
Skew Threshold  
Skew Error Response  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
Supprs  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Off  
Off  
Lvl 2  
Previous Menu  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Skew Detect Status  
Enables or disables skew detection. The default value is Off or Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Skew Detect Status.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Skew Monitor  
Skew Detect Status  
Skew Threshold  
Skew Error Response  
MODE 10 Mode Name Ftswitch Pressed  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
Ftswitch Released  
Ftswitch Cnf Tone  
Supprs  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Off  
Off  
Lvl 2  
Previous Menu  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
SkewStatus  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired status.  
NOTE: If Off or Disabled is selected, definitions for the remaining options  
will be ignored.  
A-61097 May 1997  
3-43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Skew Threshold  
This mode defines the amount of tolerable skew. If 5 Degrees is selected,  
an error will be reported if the amount of document skew is between 5 and  
30 degrees. If 10 Degrees is selected, an error will be reported if the  
amount of document skew is between 10 and 30 degrees. Regardless  
of the option selected, if the amount of document skew is greater than  
30 degrees, no error will be reported. The default value is 10 Degrees.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Skew Threshold.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Skew Monitor  
Skew Detect Status  
Skew Threshold  
Skew Error Response  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
Supprs  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Off  
Off  
Lvl 2  
Previous Menu  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
SkewThreshold  
5 Degrees  
10 Degrees  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired threshold.  
3-44  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Skew Error Response  
This mode defines the action taken if the amount of document skew is  
greater than the threshold specified. The default value is Display and  
Beep.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Skew Err Response.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Skew Monitor  
Skew Detect Status  
Skew Threshold  
Skew Error Response  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
Supprs  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Off  
Off  
Lvl 2  
Previous Menu  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Skewed Error Response  
Display  
Display and Beep  
Stop and Display  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired error response action.  
A-61097 May 1997  
3-45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Check Stacker  
NOTE: The Check Stacker must be installed.  
This mode defines when the check stacker is activated. Continuous will  
activate the check stacker whenever the side panel switch is on.  
Documents in Transport will activate the check stacker only when there  
are documents exiting the transport. The default value is Documents in  
Transport.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Check Stacker.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Check Stacker  
Continuous  
Documents in Transport  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
Previous Menu  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Off  
Off  
Lvl 2  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Select the desired option.  
3-46  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Endorser  
NOTE: The Endorser must be installed.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select Endorser.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Endorser  
Status  
Mode  
MODE 10 Mode Name Ftswitch Pressed  
Undef  
Undef  
Off  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
Ftswitch Released  
Ftswitch Cnf Tone  
Print Position  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Off  
Off  
Lvl 2  
Previous Menu  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
A-61097 May 1997  
3-47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Endorser Status  
Enables or disables the endorser. The default value is Off or Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select Status.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Endorser  
Status  
Mode  
Print Position  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
IA Field Widths  
Supprs  
4233  
Off  
Previous Menu  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Lvl 2  
Off  
Duplex  
Confirmation Tone  
N N N  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Not Used  
EndorserStatus  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired status.  
NOTE: If Off or Disabled is selected, definitions for the remaining options  
will be ignored.  
3-48  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Endorser Mode  
This mode defines whether the endorser will print continually or only once  
per document. Continuous will activate the Endorser continually. Single  
Stamp will activate the Endorser only once per document. The default  
value is Continuous.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select Mode.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Endorser  
Status  
Mode  
Print Position  
MODE 10 Mode Name Ftswitch Pressed  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
IA Field Widths  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Supprs  
4233  
Off  
Previous Menu  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Lvl 2  
Off  
Duplex  
Confirmation Tone  
N N N  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Not Used  
EndorserMode  
Continuous  
Single Stamp  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired mode.  
A-61097 May 1997  
3-49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Endorser Print Position  
This mode defines how far from the leading edge of the document the  
endorsement will appear: The default value is 0000.250 inch/  
6.350 mm.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Print Position.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Endorser  
Status  
Mode  
Print Position  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
IA Field Widths  
Supprs  
4233  
Off  
Previous Menu  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Lvl 2  
Off  
Duplex  
Confirmation Tone  
N N N  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Not Used  
Enter Print Position  
0000.250  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Range: 0.00 - 70.00  
2. Enter the desired print position within the allowable range for your  
machine type.  
— Microimager 70—0 to 70 inches or 0 to 1778 mm.  
— Scanner 900—0 to 20 inches or 0 to 500 mm.  
— Scanner 923—0 to 20 inches or 0 to 500 mm.  
— Scanner 9500—0 to 20 inches or 0 to 500 mm.  
— Scanner/Microimager 990—0 to 20 inches or  
0 to 500 mm.  
Not Used  
This mode is not selectable. It is for future use only.  
3-50  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Footswitch Pressed  
NOTE: The Footswitch accessory must be installed.  
This mode defines the action which results when the footswitch is  
pressed. The default is Undefined.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
When using a Microimager 70 without the Advanced Function Module  
installed, a limited number of actions are available. The available actions  
are:  
· Undefined  
· Level 0  
· Level 1  
· Level 2  
· Level 3  
· Increment  
When using a Microimager 70 with the Advanced Function Module  
installed, Scanner 900, Scanner 923, Scanner 9500, or Scanner/  
Microimager 990, all of the actions listed are available.  
1. Select Ftswitch Pressed.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Footswitch Pressed  
Undefined  
Level 0  
Level 1  
Level 2  
Level 3  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
Disply  
Off  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
4233  
2112  
None  
Auto  
Duplex  
?????  
1 Roll  
Comic  
Off  
Off  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Increment  
Sustained Level 0  
Sustained Level 1  
Sustained Level 2  
Sustained Level 3  
Function Key  
P-Key  
AEC Mode  
Film Mode  
Confirmation Tone  
OCR Status  
COIN User Channel  
Reduction Ratio  
# of Cassettes  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Previous Menu  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Select the desired action.  
NOTE: When Footswitch Pressed is set to undefined, F/S Released  
cannot be set.  
A-61097 May 1997  
3-51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Footswitch Released  
NOTE: The Footswitch accessory must be installed.  
This mode defines the action which results when the footswitch is  
pressed. The default is Undefined.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Ftswitch Pressed.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
FS Released  
Undefined  
Level 0  
Level 1  
Level 2  
Level 3  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Undef  
Undef  
Off  
Off  
Off  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
4233  
2112  
None  
Auto  
IA Field Widths  
Level Rules  
Batching  
Lvl 2  
Off  
Previous Menu  
AEC Mode  
Duplex  
?????  
1 Roll  
Film Mode  
Reduction Ratio  
# of Cassettes  
Confirmation Tone  
OCR Status  
COIN User Channel  
N N N  
Off  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Select the desired action.  
3-52  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Footswitch Confirmation Tone  
NOTE: The Footswitch accessory must be installed.  
This mode enables or disables the footswitch press confirmation tone. The  
default is Off or Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Ftswitch Cnf Tone.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
MODE 10 Mode Name Ftswitch Pressed  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
Ftswitch Released  
Ftswitch Cnf Tone  
Supprs  
4233  
2112  
None  
Auto  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Off  
Lvl 2  
Off  
AEC Mode  
Duplex  
?????  
1 Roll  
Film Mode  
Reduction Ratio  
# of Cassettes  
Confirmation Tone  
OCR Status  
COIN User Channel  
N N N  
Off  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Ft SwitchTone  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired action.  
NOTE: A confirmation tone is issued only when the footswitch is pressed,  
not when a footswitch is released.  
A-61097 May 1997  
3-53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Patch Reader 1  
NOTE: A Patch Reader accessory or Document Scanning Array must be  
installed.  
Enables or disables the primary patch reader. The default value is Off or  
Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Patch Reader 1.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
Supprs  
4233  
2112  
None  
Auto  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Off  
Lvl 2  
Off  
AEC Mode  
Duplex  
?????  
1 Roll  
Film Mode  
Reduction Ratio  
# of Cassettes  
Confirmation Tone  
OCR Status  
COIN User Channel  
N N N  
Off  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Units with Patch Reader  
Patch1Status  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired status.  
NOTE: IF Off or Disabled is selected, the definitions for the remaining  
patch options will be ignored.  
If you have a unit with Document Scanning Array (DSA) and you  
choose Patch Reader 1 you will get the message: Patch Reader  
1: the accessory that you requested is not installed. This is due to  
the fact that Patch Reading must be set up under barcode if you  
have a DSA.  
3-54  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Patch Reader 2  
NOTE: A Patch Reader accessories or Document Scanning Array must  
be installed.  
Enables or disables the secondary patch reader. The default value is Off  
or Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Patch Reader 2.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
IA Field Widths  
Supprs  
4233  
Off  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Lvl 2  
Off  
Duplex  
Confirmation Tone  
N N N  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
Image Mgmt Code  
Length Monitor  
OCR Status  
Off  
On  
Disply  
Off  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Off  
Secondary DP-1  
Off  
Xport  
Off  
Skew Monitor  
Check Stacker  
Endorser  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
No Sav  
F
Not Used  
Patch2Status  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired status.  
NOTE: IF Off or Disabled is selected, the definitions for the remaining  
patch options will be ignored.  
If you have a DSA, this option is not available.  
A-61097 May 1997  
3-55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Patch Definition  
NOTE: At least one Patch Reader accessory or Document Scanning  
Array must be installed.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Patch Definition.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Patch Definition  
Transfer Patch Definition  
Film Transfer Patches  
Patch Recognition  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
Supprs  
4233  
2112  
None  
Auto  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Off  
Lvl 2  
Off  
Previous Menu  
AEC Mode  
Duplex  
?????  
1 Roll  
Film Mode  
Reduction Ratio  
# of Cassettes  
Confirmation Tone  
OCR Status  
COIN User Channel  
N N N  
Off  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
3-56  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Transfer Patch Definition  
This mode defines which level should be assigned to the next document  
when a transfer patch is used. The default value is Level 2.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
1. Select Transfer Patch Definition.  
Scanner 900  
Scanner 9500  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Patch Definition  
Transfer Patch Definition  
Film Transfer Patches  
Patch Recognition  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
Supprs  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Off  
Off  
Lvl 2  
Previous Menu  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
PatchField  
Level 1  
Level 2  
Level 3  
None  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired level.  
A-61097 May 1997  
3-57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Film Transfer Patches  
This mode defines whether or not a document containing a transfer patch  
is to be filmed. The default value is Transfer Patch Filmed.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
1. Select Film Transfer Patches.  
Scanner 900  
Scanner 9500  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Patch Definition  
Transfer Patch Definition  
Film Transfer Patches  
Patch Recognition  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
3 Lvl  
Supprs  
4233  
Index Format  
IA Display Format  
IA Field Widths  
Previous Menu  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Duplex  
Confirmation Tone  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
TransferPatch  
Xfer Patch NOT Filmed  
Xfer Patch Filmed  
Not Used  
Previous Menu  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Select the desired option.  
NOTE: This selection is not available on the scanners.  
3-58  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Patch Recognition  
This mode defines which patch codes will be recognized by the system.  
The default value is 2, 3, & T.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Patch Recognition.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Patch Definition  
Transfer Patch Definition  
Film Transfer Patches  
Patch Recognition  
MODE 10 Mode Name Ftswitch Pressed  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
3 Lvl  
Supprs  
4233  
Index Format  
IA Display Format  
IA Field Widths  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Previous Menu  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Patch Recognition  
Type 2 Patches  
Duplex  
Confirmation Tone  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
Type 3 Patches  
Transfer Patches  
Type 2 & Type 3 Patches  
Type 2 & Transfer Patches  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Type 3 & Transfer Patches  
Type 2, 3 & Xfer Patches  
Previous Menu  
Not Used  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Select the patch code type(s) to be processed by the system.  
A-61097 May 1997  
3-59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bar Code  
NOTE: A Bar Code Reader must be installed.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select Bar Code.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Bar Code Reader  
Bar Code Reading Status  
Bar Code Type  
# of Bar Code Characters  
Bar Codes per Document  
Distance Between Codes  
Scan Direction  
MODE 10 Mode Name Ftswitch Pressed  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
3 Lvl  
Supprs  
4233  
Index Format  
IA Display Format  
IA Field Widths  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Image Processing  
Partial Read Enabled  
Duplex  
Confirmation Tone  
Min. Partial Characters  
?????  
1 Roll  
Comic  
Off  
Off  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
No Sav  
F
COIN User Channel  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
DSA Patch Reading Status  
Patch Horizontal Location  
End Fed Patch Read Status  
Level Change via Bar Code  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Previous Menu  
Xport  
Off  
Not Used  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
3-60  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bar Code Reading Status  
Enables or disables bar code reading. The default value is Off or  
Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Bar Code Reading Status.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Bar Code Reader  
Bar Code Reading Status  
Bar Code Type  
# of Bar Code Characters  
Bar Codes per Document  
Distance Between Codes  
Scan Direction  
Image Processing  
Partial Read Enabled  
Min. Partial Characters  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Confirmation Tone  
OCR Status  
COIN User Channel  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Duplex  
?????  
1 Roll  
DSA Patch Reading Status  
Patch Horizontal Location  
End Fed Patch Read Status  
Level Change via Bar Code  
Comic  
Off  
Off  
Film Writer  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Previous Menu  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
No Sav  
F
Bar Code Status  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired status.  
NOTE: If Off or Disabled is selected, definitions for the remaining bar  
code options will be ignored.  
A-61097 May 1997  
3-61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bar Code Type  
Identifies the type of bar code which is to be read. The default value is  
Code 39.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Bar Code Type.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Bar Code Reader  
Bar Code Reading Status  
Bar Code Type  
# of Bar Code Characters  
Bar Codes per Document  
Distance Between Codes  
Scan Direction  
Image Processing  
Partial Read Enabled  
Min. Partial Characters  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
3 Lvl  
Supprs  
4233  
Index Format  
IA Display Format  
IA Field Widths  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Duplex  
Confirmation Tone  
OCR Status  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
COIN User Channel  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
DSA Patch Reading Status  
Patch Horizontal Location  
End Fed Patch Read Status  
Level Change via Bar Code  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Previous Menu  
No Sav  
F
Bar CodeType  
Not Used  
Code 39  
Interleaved 2/5  
Codabar  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired bar code type.  
NOTE: Only one type of bar code may be read using a given mode.  
However, different modes may be defined as reading different  
types of bar code.  
3-62  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Number of Bar Code Characters  
This mode defines the minimum bar code length allowed (in terms of the  
number of characters encoded). The default value is 3.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select # of Bar Code Characters.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Bar Code Reader  
Bar Code Reading Status  
Bar Code Type  
# of Bar Code Characters  
Bar Codes per Document  
Distance Between Codes  
Scan Direction  
Image Processing  
Partial Read Enabled  
Min. Partial Characters  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
3 Lvl  
Supprs  
4233  
Index Format  
IA Display Format  
IA Field Widths  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Duplex  
Confirmation Tone  
OCR Status  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
COIN User Channel  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
DSA Patch Reading Status  
Patch Horizontal Location  
End Fed Patch Read Status  
Level Change via Bar Code  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Previous Menu  
No Sav  
F
Not Used  
Enter Minumum Length  
Range: 03 - 80 Characters  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
03  
2. Select the desired minimum length within the range 3 - 80.  
A-61097 May 1997  
3-63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bar Codes per Document  
This mode defines the number of bar codes per document to be decoded.  
The default value is One Code.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Bar Codes per Document.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Bar Code Reader  
Bar Code Reading Status  
Bar Code Type  
# of Bar Code Characters  
Bar Codes per Document  
Distance Between Codes  
Scan Direction  
Image Processing  
Partial Read Enabled  
Min. Partial Characters  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
3 Lvl  
Supprs  
4233  
Index Format  
IA Display Format  
IA Field Widths  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Duplex  
Confirmation Tone  
OCR Status  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
COIN User Channel  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
DSA Patch Reading Status  
Patch Horizontal Location  
End Fed Patch Read Status  
Level Change via Bar Code  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Previous Menu  
No Sav  
F
Not Used  
DocumentCodes  
One Code  
All Codes  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired number of codes to be decoded.  
3-64  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Distance Between Codes  
This mode defines the minimum bar code height allowed. The height of  
the tallest bar code determines the distance between codes. The default  
value is 1.000 inch/25.400 mm.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
1. Select Distance Between Codes.  
Scanner 900  
Scanner 9500  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
*** NOTE ***  
Distance between bar codes  
must be greater than height  
of largest bar code.  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
3 Lvl  
Supprs  
4233  
Index Format  
IA Display Format  
IA Field Widths  
*** HINT ***  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Always add one “click” to  
height of largest code.  
Duplex  
Confirmation Tone  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
Image Mgmt Code  
Length Monitor  
OCR Status  
Off  
On  
Disply  
Off  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Distance Between Codes  
1.000  
25.400 mm Default  
Off  
Secondary DP-1  
Off  
Xport  
Off  
Skew Monitor  
Check Stacker  
Endorser  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
No Sav  
F
Press ENTER to return  
to Previous Menu.  
Not Used  
0.375 in.  
9.53 mm  
3.000 in.  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
76.20 mm  
2. Select the desired bar code height/distance between codes within the  
range 0.375 inch to 3 inches or 9.53 mm to 76.20 mm by pressing the  
left/right arrow key(s) to decrement/increment the default value by  
0.125 inch or 3.18 mm at a time.  
A-61097 May 1997  
3-65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Scan Direction  
This mode defines whether the bar codes may be read in only one  
direction (from left to right) or in either direction (from left to right or from  
right to left). The default value is Unidirectional (from left to right only).  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Scan Direction.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Bar Code Reader  
Bar Code Reading Status  
Bar Code Type  
# of Bar Code Characters  
Bar Codes per Document  
Distance Between Codes  
Scan Direction  
Image Processing  
Partial Read Enabled  
Min. Partial Characters  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Confirmation Tone  
OCR Status  
COIN User Channel  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Duplex  
?????  
1 Roll  
DSA Patch Reading Status  
Patch Horizontal Location  
End Fed Patch Read Status  
Level Change via Bar Code  
Comic  
Off  
Off  
Film Writer  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Previous Menu  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
No Sav  
F
Scan Direction  
Uni-directional  
Bi-directional  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired scan direction.  
3-66  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Image Processing  
Enables or disables image processing; indicates whether or not image  
processing is required to enhance the overall quality of the bar codes  
used. The default value is Off or Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Image Processing.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Bar Code Reader  
Bar Code Reading Status  
Bar Code Type  
# of Bar Code Characters  
Bar Codes per Document  
Distance Between Codes  
Scan Direction  
Image Processing  
Partial Read Enabled  
Min. Partial Characters  
MODE 10 Mode Name Ftswitch Pressed  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
Ftswitch Released  
Ftswitch Cnf Tone  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Duplex  
?????  
1 Roll  
COIN User Channel  
DSA Patch Reading Status  
Patch Horizontal Location  
End Fed Patch Read Status  
Level Change via Bar Code  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Previous Menu  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
No Sav  
F
Image Process  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired image processing status.  
A-61097 May 1997  
3-67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Partial Read Enabled  
Enables or disables partial bar code reading. The default value is Off or  
Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Partial Read Enabled.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Bar Code Reader  
Bar Code Reading Status  
Bar Code Type  
# of Bar Code Characters  
Bar Codes per Document  
Distance Between Codes  
Scan Direction  
Image Processing  
Partial Read Enabled  
Min. Partial Characters  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Confirmation Tone  
OCR Status  
COIN User Channel  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Duplex  
?????  
1 Roll  
DSA Patch Reading Status  
Patch Horizontal Location  
End Fed Patch Read Status  
Level Change via Bar Code  
Comic  
Off  
Off  
Film Writer  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Previous Menu  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
No Sav  
F
BC Partial Read  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired status.  
3-68  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Minimum Partial Characters  
NOTE: Partial Reading must be enabled or this definition will be ignored.  
This mode defines the minimum number of characters which must be  
properly decoded to constitute a partial read. The default value is 5-80.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Min. Partial Characters.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Bar Code Reader  
Bar Code Reading Status  
Bar Code Type  
# of Bar Code Characters  
Bar Codes per Document  
Distance Between Codes  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Confirmation Tone  
OCR Status  
COIN User Channel  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Scan Direction  
Image Processing  
Partial Read Enabled  
Min. Partial Characters  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Duplex  
?????  
1 Roll  
DSA Patch Reading Status  
Patch Horizontal Location  
End Fed Patch Read Status  
Level Change via Bar Code  
Comic  
Off  
Off  
Film Writer  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Previous Menu  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
No Sav  
F
Enter Minumum Length  
Range: 05 - 80 Characters  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
05  
2. Select the desired number of characters.  
A-61097 May 1997  
3-69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DSA Patch Reading Status  
Enables or disables patch reading using the Document Scanning Array.  
The default value is Off or Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select DSA Patch Reading Status.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Bar Code Reader  
Bar Code Reading Status  
Bar Code Type  
# of Bar Code Characters  
Bar Codes per Document  
Distance Between Codes  
Scan Direction  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
3 Lvl  
Supprs  
4233  
Index Format  
IA Display Format  
IA Field Widths  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Image Processing  
Partial Read Enabled  
Duplex  
Confirmation Tone  
Min. Partial Characters  
?????  
1 Roll  
Comic  
Off  
Off  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
No Sav  
F
COIN User Channel  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
DSA Patch Reading Status  
Patch Horizontal Location  
End Fed Patch Read Status  
Level Change via Bar Code  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Previous Menu  
Xport  
Off  
Not Used  
Field  
BC Partial Read  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired status.  
NOTE: If patch reading is enabled using the DSA, make certain to  
complete the Patch Definition items.  
Patches must be at least 2 inches in length.  
3-70  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Patch Horizontal Location  
This mode defines the position of patches on the document(s) in terms of  
the distance from the left side of the transport. The default value is  
5.12 inches/130.048 mm.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Patch Horizontal Location.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Bar Code Reader  
Bar Code Reading Status  
Bar Code Type  
# of Bar Code Characters  
Bar Codes per Document  
Distance Between Codes  
Scan Direction  
Image Processing  
Partial Read Enabled  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
3 Lvl  
Supprs  
4233  
Index Format  
IA Display Format  
IA Field Widths  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Duplex  
Confirmation Tone  
OCR Status  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
COIN User Channel  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Bar Code Patch Position  
Image Mgmt Code  
5.120  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
130.048 mm Default  
Press ENTER to return  
No Sav  
F
to Previous Menu.  
Not Used  
1.92 in.  
48.77 mm  
9.60 in.  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
243.84 mm  
2. Select the desired location within the range 1.92 to 9.6 inches or  
48.75 mm to 243.84 mm by pressing the left/right arrow key(s) to  
decrement/increment the default value by 0.64 inch or 16.25 mm at a  
time.  
A-61097 May 1997  
3-71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
End Fed Patch Reading Status  
Enables or disables end fed patch reading using the Document Scanning  
Array. The default value is Off or Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select End Fed Patch Read Status.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Bar Code Reader  
Bar Code Reading Status  
Bar Code Type  
# of Bar Code Characters  
Bar Codes per Document  
Distance Between Codes  
Scan Direction  
Image Processing  
Partial Read Enabled  
Min. Partial Characters  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Confirmation Tone  
OCR Status  
COIN User Channel  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Duplex  
?????  
1 Roll  
DSA Patch Reading Status  
Patch Horizontal Location  
End Fed Patch Read Status  
Level Change via Bar Code  
Comic  
Off  
Off  
Film Writer  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Previous Menu  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
No Sav  
F
End FedPatch  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired status.  
NOTE: If patch reading is enabled using the DSA, make certain to  
complete the Patch Definition items. Also, end fed patches must  
be located within 3.75 inches or 95.3 mm of the leading edge of  
the document(s).  
3-72  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Level Change via Bar Code  
Enables level changes based upon detection of a bar code. The default  
value is Undefined.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Level Change via Bar Code.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Bar Code Reader  
Bar Code Reading Status  
Bar Code Type  
# of Bar Code Characters  
Bar Codes per Document  
Distance Between Codes  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Confirmation Tone  
OCR Status  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Scan Direction  
Image Processing  
Partial Read Enabled  
Min. Partial Characters  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Duplex  
?????  
1 Roll  
COIN User Channel  
DSA Patch Reading Status  
Comic  
Off  
Off  
Off  
Xport  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Disply  
Off  
Off  
Off  
Off  
Patch Horizontal Location  
End Fed Patch Read Status  
Level Change via Bar Code  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Previous Menu  
PatchLevel  
Level 0  
Level 1  
Level 2  
Level 3  
No Sav  
F
Not Used  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Undefined  
Previous Menu  
2. Select the desired level to be assigned when a bar code is detected.  
NOTE: It is recommended that patch codes, rather than bar codes, be  
used to perform document level changes. Using patch codes to  
alter document image levels is much more reliable and accurate  
than the use of bar codes to alter document image levels. The  
lower reliability level which may be experienced using bar codes  
to alter document image levels may have serious ramifications,  
depending upon the application. It is suggested that you contact  
Marketing Support in Rochester if you wish to implement this  
feature.  
A-61097 May 1997  
3-73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Confirmation Tones  
NOTE: The tones must have been enabled during machine configuration;  
otherwise, these definitions will be ignored.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Confirmation Tone.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Confirmation Tone  
Patch Detected Tone  
Bar Detected Tone  
MODE 10 Mode Name Ftswitch Pressed  
Undef  
Undef  
Off  
Off  
Off  
3 Lvl  
Index Format  
IA Display Format  
IA Field Widths  
Level Rules  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code/Patch Tone  
Supprs  
4233  
2112  
None  
Previous Menu  
Batching  
Lvl 2  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Film Writer  
Bar Code  
Confirmation Tone  
OCR Status  
COIN User Channel  
Printer Control  
Off  
N N N  
Off  
On  
Disply  
Duplex  
?????  
1 Roll  
Comic  
Off  
Off  
Off  
Xport  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Primary DP-1  
Off  
Off  
Off  
Off  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
No Sav  
Not Used  
Film Definition  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
3-74  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Patch Detected Tone  
NOTE: Patch reading must be enabled. In addition, the confirmation  
tones must have been enabled during machine definitions;  
otherwise, this definition will be ignored.  
This mode enables or disables a confirmation tone issued when a patch  
document is detected. The default value is Off or Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Patch Detected Tone.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Confirmation Tone  
Patch Detected Tone  
Bar Detected Tone  
Bar Code/Patch Tone  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
3 Lvl  
Supprs  
4233  
Index Format  
IA Display Format  
IA Field Widths  
Previous Menu  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Duplex  
Confirmation Tone  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Not Used  
PatchTone  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired status.  
NOTE: If the Patch Detected Tone is enabled, the Bar Code/Patch Tone  
cannot be enabled. However, the Bar Detected Tone may be  
enabled.  
A-61097 May 1997  
3-75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bar Detected Tone  
NOTE: Bar Code reading must be enabled. In addition, during machine  
definitions the confirmation tones must have been enabled;  
otherwise, this definition will be ignored.  
Enables or disables a confirmation tone issued when a bar code  
document is detected. The default value is Off or Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Bar Detected Tone.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Confirmation Tone  
Patch Detected Tone  
Bar Detected Tone  
Bar Code/Patch Tone  
MODE 10 Mode Name Ftswitch Pressed  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
3 Lvl  
Supprs  
4233  
Index Format  
IA Display Format  
IA Field Widths  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Previous Menu  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Duplex  
Confirmation Tone  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Not Used  
Field  
Bar Code Tone  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired status.  
NOTE: If the Bar Detected Tone is enabled, the Bar Code/Patch Tone  
cannot be enabled. However, the Patch Detected Tone may be  
enabled.  
3-76  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bar Code/Patch Tone  
NOTE: Patch reading and Bar Code reading must be enabled. In  
addition, the confirmation tones must have been enabled during  
machine definitions; otherwise, this definition will be ignored.  
Enables or disables a confirmation tone issued when a bar code and a  
patch are both recognized. The default value is Off or Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Bar Code/Patch Tone.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Confirmation Tone  
Patch Detected Tone  
Bar Detected Tone  
Bar Code/Patch Tone  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
Supprs  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Off  
Off  
Lvl 2  
Previous Menu  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
BC/PatchTone  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired status.  
NOTE: If either the Patch Detected Tone or Bar Detected Tone is  
enabled, the Bar Code/Patch Tone cannot be enabled.  
A-61097 May 1997  
3-77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OCR Status  
NOTE: The OCR accessory must be installed.  
Enables or disables Optical Character Recognition. The default value is  
Off or Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select OCR Status.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
Supprs  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Off  
Off  
Lvl 2  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
OCRStatus  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired status.  
3-78  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COIN User Channel  
NOTE: If the machine definition User COIN Port Protocol was disabled,  
these definitions will be ignored.  
Enables or disables the COIN2 user channel.  
If a standard form of output was chosen during machine definition (Bar  
Code/KDIS Protocol or OCR Data Protocol), this definition should be set  
to Enabled which will produce default/standard data output via the COIN2  
port.  
If a user-defined form of output was chosen during machine definition  
(User-Defined KDIS Format or User-Defined Protocol), select Define All  
Levels or select a particular level. The default value is Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select COIN User Channel.  
2. Select the desired status.  
A-61097 May 1997  
3-79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Transmit Data  
This mode defines the data output via the COIN2 port when a user-  
defined protocol (User-Defined KDIS Format or User-Defined Protocol) is  
chosen during machine definition. The default values are FF/IA for all  
levels.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
If the same information is to be transmitted for documents of all levels:  
1. Select Define All Levels.  
Transmit Items  
Current Transmit Sequence  
<FF/IA>  
Full Image Address  
Indexed Field(s) Only  
Current Field Value  
Current Day  
Current Date  
Current Time  
Document Counter  
Roll Number  
Attachment Count  
Bar Code Data  
Nothing  
New Transmit Sequence  
Previous Menu  
When using a Microimager 70 with the Advanced Function Module  
installed, Scanner 900, Scanner 923, Scanner 9500, or Scanner/  
Microimager 990, all of the transmit items are available for selection, with  
a maximum of seven (7) items.  
2. Select the item(s) to be transmitted.  
3-80  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If different information is to be transmitted for documents of different  
levels:  
1. Select Define Level # for the desired level.  
Transmit Items  
Full Image Address  
Indexed Field(s) Only  
Current Field Value  
Current Day  
Current Transmit Sequence  
<FF/IA>  
Current Date  
Current Time  
Document Counter  
Roll Number  
Attachment Count  
New Transmit Sequence  
Bar Code Data  
Nothing  
Previous Menu  
When using a Microimager 70 without the Advanced Function Module  
installed, a limited number of transmit items may be selected. The valid  
items are:  
· Full Image Address  
· Nothing  
When using a Microimager 70 with the Advanced Function Module  
installed, Scanner 900, Scanner 923, Scanner 9500, or Scanner/  
Microimager 990, all of the transmit items are available for selection, with  
a maximum of seven (7) items.  
2. Select the item(s) to be transmitted.  
A-61097 May 1997  
3-81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Printer Control  
NOTE: The Document Printer Controller must be installed  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Printer Control.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Printer Control  
IA Print Format  
Print Position  
Special Character Set  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
IA Field Widths  
Supprs  
4233  
Off  
Previous Menu  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Lvl 2  
Off  
Duplex  
Confirmation Tone  
N N N  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Not Used  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Image Address Print Format  
This mode defines the format used by the document printer(s) when  
printing the Image Address. The default value is Display.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select IA Print Format.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Printer Control  
IA Print Format  
Print Position  
Special Character Set  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
Supprs  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Off  
Off  
Lvl 2  
Previous Menu  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Film Writer  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Bar Code  
Confirmation Tone  
OCR Status  
COIN User Channel  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
N N N  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
No Sav  
F
Examples of Formats  
Duplex  
?????  
1 Roll  
Comic  
Off  
Off  
Off  
Xport  
Off  
Display: 001.002.003.004  
Compress:001.2.3.4  
Suppress: 001. 002.003.004  
DP IA Display Format  
Display Leading Zeroes  
Compress Leading Zeroes  
Suppress Leading Zeroes  
Not Used  
Previous Menu  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Select the desired print format.  
3-82  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Print Position  
This mode defines how far from the leading edge of the document(s) the  
information printed by the document printer(s) will appear. The default  
value is 00.250 inch/6.25 mm.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Print Position.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Printer Control  
IA Print Format  
Print Position  
Special Character Set  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
Supprs  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Off  
Off  
Lvl 2  
Previous Menu  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Enter Print Position  
Range: 0.125...20.000  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
0000.250  
2. Select the desired print position with the range 0.125 to 75 inches or  
3.000 to 1905.000 mm).  
A-61097 May 1997  
3-83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Special Character Set  
This mode defines the size font to be printed. Select either the smaller or  
larger font size when using the Document Printer 12. The default value is  
Use Smaller Font.  
NOTE: This selection is not available if the wrong printer driver board is  
installed. The following message appears:  
Incorrect revision of 3100 PCB for Bigfoot Font  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Special Character Set.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Printer Control  
IA Print Format  
Print Position  
Special Character Set  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
3 Lvl  
Supprs  
4233  
Index Format  
IA Display Format  
IA Field Widths  
Previous Menu  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Duplex  
Confirmation Tone  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Not Used  
Field  
Character Set  
Use Smaller Font  
Use Larger Font  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired font size.  
3-84  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Primary Document Printer 1  
NOTE: A Document Printer 1 accessory must be installed.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Primary DP-1.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Primary Document Printer  
Document Printer Status  
Fonts/Orientation  
Same Format per Level  
Print Sequence - Level 0  
Print Sequence - Level 1  
Print Sequence - Level 2  
Print Sequence - Level 3  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Confirmation Tone  
OCR Status  
COIN User Channel  
Printer Control  
Primary DP-1  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
3 Lvl  
Supprs  
4233  
Index Format  
IA Display Format  
IA Field Widths  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Duplex  
Previous Menu  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
Disply  
Off  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Not Used  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Document Printer Status  
This mode enables or disables the primary Document Printer 1. The  
default value is Off or Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Document Printer Status.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Primary Document Printer  
Document Printer Status  
Fonts/Orientation  
Same Format per Level  
Print Sequence - Level 0  
Print Sequence - Level 1  
Print Sequence - Level 2  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
3 Lvl  
Supprs  
4233  
2112  
None  
Auto  
Index Format  
IA Display Format  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 2  
Patch Definition  
Bar Code  
Print Sequence - Level 3  
AEC Mode  
Film Mode  
Duplex  
Confirmation Tone  
Previous Menu  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Not Used  
PrimaryStatus  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired status.  
A-61097 May 1997  
3-85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fonts/Orientation  
This mode defines the size and orientation of the characters printed by the  
primary Document Printer 1. The default value is Off or Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Fonts/Orientation.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Primary Document Printer  
Document Printer Status  
Fonts/Orientation  
Same Format per Level  
Print Sequence - Level 0  
Print Sequence - Level 1  
Print Sequence - Level 2  
Print Sequence - Level 3  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
3 Lvl  
Index Format  
IA Display Format  
IA Field Widths  
Level Rules  
Supprs  
4233  
2112  
None  
Batching  
Auto  
AEC Mode  
Bar Code  
Duplex  
?????  
1 Roll  
Comic  
Off  
Off  
Off  
Xport  
Off  
Film Mode  
Confirmation Tone  
OCR Status  
COIN User Channel  
Printer Control  
N N N  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
No Sav  
Previous Menu  
Reduction Ratio  
# of Cassettes  
Film Writer  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
DP-1 Font Selection  
Small Font - Comic  
Small Font - Cine  
Small Font - Comic 180  
Small Font - Cine 180  
Large Font - Comic  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Not Used  
Film Definition  
F
Large Font - Cine  
Large Font - Comic 180  
Large Font - Cine 180  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired size and font (four orientations).  
0
C
8
I
1
N
E
E
N
I
C
3-86  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Print Definitions  
This mode defines the information printed on each document, based upon  
the document level.  
The default values are Nothing Printed for Level 0 documents; Full Image  
Address with all delimiters for Level 1, Level 2, and Level 3 documents  
<FF/IA All Del>.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
If the same information is to be printed on documents of all levels:  
1. Select Same Format per Level.  
Print Items  
Current Print Sequence Display Values  
Full IA w/No Delimiters  
Full IA w/FF Delimiter  
Full IA w/All Delimiter  
Fixed Field Only  
Indexed Fields Only  
Current Field Level  
Spaces between Items  
Current Day  
Current Date  
New Print Sequence Display Values  
Current Time  
Document Counter  
Roll Number  
Message 1-9  
Check Digit  
Nothing Printed  
Previous Menu  
When using a Microimager 70 without the Advanced Function Module  
installed, a limited number of items may be selected. The available items  
are:  
· Full IA w/ All Delimiter  
· Indexed Fields Only  
· Nothing Printed  
When using a Microimager 70 with the Advanced Function Module  
installed, all of the items are available for selection, with a maximum of  
38 characters (including spaces).  
NOTE: If the definition exceeds the 38 character limit, the first 38  
characters will be printed on each document and the remainder of  
the information will be truncated.  
2. Select the item(s) to be printed.  
A-61097 May 1997  
3-87  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If Spaces between items is selected, you must select the desired number  
of spaces.  
If Check Digit is selected, the following window is displayed:  
Check Digit  
Current Print Sequence Display Values  
Mod 7A  
IA Only  
Mod 11A IA Only  
Mod 7B  
IA Only  
Mod 7B  
Mod 10  
Mod 10  
Full IA  
IA Only  
Full IA  
Mod 11B IA Only  
Mod 11B Full IA  
New Print Sequence Display Values  
Custom  
Custom  
IA Only  
Full IA  
Previous Menu  
2. Select the desired check digit calculation.  
If an option which indicates IA Only is chosen, the level fields of the Image  
Address will be printed; the Fixed Field will not be printed. If an option  
which indicates Full IA is chosen, the Fixed Field and level fields of the  
Image Address will be printed.  
NOTE: If Customer - IA Only or Customer - Full IA is chosen, the Check  
Digit options must be defined.  
If Message Number is selected, the following window is displayed:  
Message Number  
Message Number 1  
Message Number 2  
Current Print Sequence Display Values  
Message Number 3  
Message Number 4  
Message Number 5  
Message Number 6  
Message Number 7  
Message Number 8  
Message Number 9  
New Print Sequence Display Values  
Previous Menu  
1. Select the desired message number.  
3-88  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If different information is to be printed on documents of different levels:  
1. Select Print Sequence - Level # for the desired level.  
Print Items  
Current Print Sequence Display Values  
Full IA w/No Delimiters  
Full IA w/FF Delimiter  
Full IA w/All Delimiter  
Fixed Field Only  
Indexed Fields Only  
Current Field Level  
Spaces between Items  
Current Day  
New Print Sequence Display Values  
Current Date  
Current Time  
Document Counter  
Roll Number  
Message 1-9  
Check Digit  
Nothing Printed  
Previous Menu  
When using a Microimager 70 without the Advanced Function Module  
installed, a limited number of items may be selected. The available items  
are:  
· Full IA w/ All Delimiter  
· Indexed Fields Only  
· Nothing Printed  
When using a Microimager 70 with the Advanced Function Module  
installed, all of the items are available for selection, with a maximum of  
38 characters (including spaces).  
If Check Digit is selected, the following window is displayed:  
NOTE: If the definition exceeds the thirty-eight (38) character limits, the  
first thirty-eight (38) characters will be printed on each document  
and the remainder of the information will be truncated.  
2. Select the item(s) to be printed.  
A-61097 May 1997  
3-89  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Secondary Document Printer 1  
NOTE: Two Document Printer 1 accessories must be installed.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Secondary DP-1.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Second Document Printer  
Document Printer Status  
Fonts/Orientation  
Same Format per Level  
Print Sequence - Level 0  
Print Sequence - Level 1  
Print Sequence - Level 2  
Print Sequence - Level 3  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Confirmation Tone  
OCR Status  
COIN User Channel  
Printer Control  
Primary DP-1  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
Off  
On  
3 Lvl  
Supprs  
4233  
Index Format  
IA Display Format  
IA Field Widths  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Duplex  
Previous Menu  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
Disply  
Off  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Not Used  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
3-90  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Document Printer Status  
Enables or disables the secondary Document Printer 1. The default value  
is Off or Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Document Printer Status.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Second Document Printer  
Document Printer Status  
Fonts/Orientation  
Same Format per Level  
Print Sequence - Level 0  
Print Sequence - Level 1  
Print Sequence - Level 2  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Print Sequence - Level 3  
Auto  
AEC Mode  
Bar Code  
Duplex  
?????  
1 Roll  
Film Mode  
Reduction Ratio  
# of Cassettes  
Confirmation Tone  
OCR Status  
COIN User Channel  
N N N  
Off  
On  
Previous Menu  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Secondary DP-1  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired status.  
A-61097 May 1997  
3-91  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fonts/Orientation—DP2  
This mode defines the size and orientation of the characters printed by the  
secondary Document Printer 1. The default value is Off or Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Fonts/Orientation.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Second Document Printer  
Document Printer Status  
Fonts/Orientation  
Same Format per Level  
Print Sequence - Level 0  
Print Sequence - Level 1  
Print Sequence - Level 2  
Print Sequence - Level 3  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
3 Lvl  
Supprs  
4233  
Index Format  
IA Display Format  
IA Field Widths  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Duplex  
Confirmation Tone  
Previous Menu  
?????  
1 Roll  
Comic  
Off  
Off  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
No Sav  
F
COIN User Channel  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
DP-1 FontSelection  
Small Font - Comic  
Small Font - Cine  
Small Font - Comic 180  
Small Font - Cine 180  
Large Font - Comic  
Large Font - Cine  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Xport  
Off  
Not Used  
Large Font - Comic 180  
Large Font - Cine 180  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired size and font (four orientations).  
0
C
8
I
1
N
E
E
N
I
C
3-92  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Print Definitions—DP2  
This mode defines the information printed on each document, based upon  
the document level. The default values are Nothing Printed for Level 0  
documents; Full Image Address with all delimiters for Level 1, Level 2, and  
Level 3 documents.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
If the same information is to be printed on documents of all levels:  
1. Select Same Format per Level.  
Print Items  
Current Print Sequence Display Values  
Full IA w/No Delimiters  
Full IA w/FF Delimiter  
Full IA w/All Delimiter  
Fixed Field Only  
Indexed Fields Only  
Current Field Level  
Spaces between Items  
Current Day  
New Print Sequence Display Values  
Current Date  
Current Time  
Document Counter  
Roll Number  
Message 1-9  
Check Digit  
Nothing Printed  
Previous Menu  
2. Select the item(s) to be printed, in turn, up to a maximum of thirty-  
eight (38) characters, including spaces.  
NOTE: If the definition exceeds the thirty-eight (38) character limit, the  
first thirty-eight (38) characters will be printed on each document  
and the remainder of the information will be truncated.  
If Spaces between Items is selected, you must select the desired number  
of spaces.  
A-61097 May 1997  
3-93  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If Check Digit is selected, the following window is displayed:  
Check Digit  
IA Only  
Current Print Sequence Display Values  
Mod 7A  
Mod 11A IA Only  
Mod 7B  
IA Only  
Mod 7B  
Mod 10  
Mod 10  
Full IA  
IA Only  
Full IA  
Mod 11B IA Only  
Mod 11B Full IA  
New Print Sequence Display Values  
Custom  
Custom  
IA Only  
Full IA  
Previous Menu  
3. Select the desired check digit calculation.  
If an option which indicates IA Only is chosen, the level fields of the Image  
Address will be printed; the Fixed Field will not be printed. If an option  
which indicates Full IA is chosen, the Fixed Field and level fields of the  
Image Address will be printed.  
NOTE: If Customer—IA Only or Customer—Full IA is chosen, the Check  
Digit options must be defined.  
3-94  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If Message Number is selected, the following window is displayed:  
Message Number  
Message Number 1  
Message Number 2  
Current Print Sequence Display Values  
Message Number 3  
Message Number 4  
Message Number 5  
Message Number 6  
Message Number 7  
Message Number 8  
Message Number 9  
New Print Sequence Display Values  
Previous Menu  
4. Select the desired message number.  
If different information is to be printed on documents of different levels:  
5. Select Print Sequence—Level # for the desired level.  
6. Select the item(s) to be printed next to documents of the selected  
level, in turn, up to a maximum of thirty-eight (38) characters, including  
spaces.  
NOTE: If the definition exceeds the thirty-eight (38) character limit, the  
first thirty-eight (38) characters will be printed on each document  
and the remainder of the information will be truncated.  
A-61097 May 1997  
3-95  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Document Printer 12  
NOTE: The Document Printer 12 accessory must be installed  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Doc. Printer 12.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Document Printer 12  
Document Printer Status  
Fonts/Orientation  
Same Format per Level  
Print Sequence - Level 0  
Print Sequence - Level 1  
Print Sequence - Level 2  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Print Sequence - Level 3  
Auto  
AEC Mode  
Bar Code  
Duplex  
?????  
1 Roll  
Film Mode  
Reduction Ratio  
# of Cassettes  
Confirmation Tone  
OCR Status  
COIN User Channel  
N N N  
Off  
On  
Previous Menu  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
3-96  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Document Printer Status—DP12  
Enables or disables the Document Printer 12. The default value is Off or  
Disabled.  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
1. Select Document Printer Status.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Document Printer 12  
Document Printer Status  
Fonts/Orientation  
Same Format per Level  
Print Sequence - Level 0  
Print Sequence - Level 1  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Print Sequence - Level 2  
Print Sequence - Level 3  
Auto  
AEC Mode  
Bar Code  
Duplex  
?????  
1 Roll  
Film Mode  
Reduction Ratio  
# of Cassettes  
Confirmation Tone  
OCR Status  
COIN User Channel  
N N N  
Off  
On  
Previous Menu  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
PAW12Status  
Off or Disabled  
On or Enabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired status.  
A-61097 May 1997  
3-97  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fonts/Orientation—DP12  
This mode defines the size and orientation of the characters printed by the  
Document Printer 12. The default value is Comic Orientation.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Fonts/Orientation.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Document Printer 12  
Document Printer Status  
Fonts/Orientation  
Same Format per Level  
Print Sequence - Level 0  
Print Sequence - Level 1  
Print Sequence - Level 2  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
3 Lvl  
Supprs  
Index Format  
IA Display Format  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Print Sequence - Level 3  
Auto  
AEC Mode  
Bar Code  
Duplex  
?????  
1 Roll  
Film Mode  
Reduction Ratio  
# of Cassettes  
Confirmation Tone  
OCR Status  
COIN User Channel  
N N N  
Off  
On  
Previous Menu  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
DP-12 Font Selection  
Comic Orientation  
Comic 180 Orientation  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
2. Select the desired size and font.  
COMIC  
3-98  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Print Definitions—DP12  
This mode defines the information printed on each document, based upon  
the document level. The default values are No Print Template for Level 0  
documents; Print Template for Level 1, Level 2, and Level 3 documents.  
The default is IA-No Del.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
If the same information is to be printed on documents of all levels.  
1. Select Same Format per Level.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Document Printer 12  
Document Printer Status  
Fonts/Orientation  
Same Format per Level  
Print Sequence - Level 0  
Print Sequence - Level 1  
Print Sequence - Level 2  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
3 Lvl  
Supprs  
4233  
2112  
None  
Auto  
Index Format  
IA Display Format  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 2  
Patch Definition  
Bar Code  
Print Sequence - Level 3  
AEC Mode  
Film Mode  
Duplex  
Confirmation Tone  
Previous Menu  
?????  
1 Roll  
Comic  
Off  
Off  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
No Sav  
F
PrintLevel*  
Print Template 1  
COIN User Channel  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Print Template 2  
Print Template 3  
Print Template 4  
Print Template 5  
Print Template 6  
Print Template 7  
Print Template 8  
Print Template 9  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Xport  
Off  
Not Used  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Print Template 10  
No Print Template  
Previous Menu  
When using a Microimager 70 without the Advanced Function Module  
installed, a limited number of items may be selected. The available items  
are:  
· Print Template 1  
· No Print Template  
A-61097 May 1997  
3-99  
Download from Www.Somanuals.com. All Manuals Search And Download.  
When using a Microimager 70 with the Advanced Function Module  
installed, all of the print templates defined during machine configuration  
are available for selection.  
2. Select the print template which contains the information to be printed  
on all documents.  
3. Select Print Sequence—Level # for the desired level.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Document Printer 12  
Document Printer Status  
Fonts/Orientation  
Same Format per Level  
Print Sequence - Level 0  
Print Sequence - Level 1  
Print Sequence - Level 2  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
Off  
Off  
Lvl 2  
Off  
N N N  
3 Lvl  
Supprs  
4233  
2112  
None  
Auto  
Index Format  
IA Display Format  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 2  
Patch Definition  
Bar Code  
Print Sequence - Level 3  
AEC Mode  
Film Mode  
Duplex  
Confirmation Tone  
Previous Menu  
?????  
1 Roll  
Comic  
Off  
Off  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
No Sav  
F
PrintLevel*  
Print Template 1  
COIN User Channel  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Print Template 2  
Print Template 3  
Print Template 4  
Print Template 5  
Print Template 6  
Print Template 7  
Print Template 8  
Print Template 9  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Xport  
Off  
Not Used  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Print Template 10  
No Print Template  
Previous Menu  
When using a Microimager 70 without the Advanced Function Module  
installed, a limited number of items may be selected. The available items  
are:  
· Print Template 1  
· No Print Template  
When using a Microimager 70 with the Advanced Function Module  
installed, all of the print templates defined during machine configuration  
are available for selection.  
4. Select the print template which contains the information to be printed  
on all documents.  
3-100  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Document Sorter OFF  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
Select Document Sorter and the following screen appears:  
Mode Number: 10  
Sort Criteria  
Mode Name: MODE10  
Bin  
Document Sorter  
Status  
Error Response  
Sort Criteria  
Default Stopper  
Level 0 Docs  
Level 1 Docs  
Level 2 Docs  
Level 3 Docs  
Upper  
Default  
Default  
Default  
Default  
Transfer Patch  
Level III Patch  
Level II Patch  
Bar Code Docs  
Partial Read BC  
Docs w/o Bar Code  
BC/Patch Docs  
Default  
Default  
Default  
Default  
Default  
Default  
Default  
Status  
Off or Disable  
On or Enabled  
Skewed Documents  
Length Error Docs  
Default  
Default  
Error Response  
Display Only  
Beep and Display  
Stop and Display  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Select any of the Sort Criteria and the following screen appears:  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Hopper Selection  
Default Hopper  
Lower Hopper  
Upper Hopper  
MODE 10 Mode Name  
Ftswitch Pressed  
Undef  
Undef  
Off  
3 Lvl  
Supprs  
4233  
Index Format  
IA Display Format  
IA Field Widths  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Off  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Lvl 2  
Off  
Duplex  
?????  
1 Roll  
Film Mode  
Reduction Ratio  
# of Cassettes  
Confirmation Tone  
OCR Status  
COIN User Channel  
N N N  
Off  
On  
Previous Menu  
Comic  
Off  
Off  
Film Writer  
Image Mgmt Code  
Length Monitor  
Printer Control  
Primary DP-1  
Secondary DP-1  
Disply  
Off  
Off  
Off  
Xport  
Off  
Skew Monitor  
Check Stacker  
Endorser  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Off  
Off  
No Sav  
Not Used  
Film Definition  
F
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
A-61097 May 1997  
3-101  
Download from Www.Somanuals.com. All Manuals Search And Download.  
If 4 selections have been set and you choose a 5th option, the following  
screen appears:  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
** ERROR **  
Maximum number of sorting  
criteria has been reached  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
IA Field Widths  
Supprs  
4233  
Press ENTER to proceed…  
Off  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Lvl 2  
Off  
Duplex  
Confirmation Tone  
N N N  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
Image Mgmt Code  
Length Monitor  
OCR Status  
Off  
On  
Disply  
Off  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Off  
Secondary DP-1  
Off  
Xport  
Off  
Skew Monitor  
Check Stacker  
Endorser  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
No Sav  
F
Not Used  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Mode Overrides  
This mode enables or disables mode overrides. Enabling this option  
means that permanent changes may be made to the original mode option  
definitions using select function codes during operation. Disabling this  
option means that changes made to the original mode option definitions  
using select function codes during operation are temporary. The default  
value is Discard Overrides.  
Microimager 70 Microimager 70/AFM  
Scanner 923 Scanner/Microimager 990  
Scanner 900  
Scanner 9500  
1. Select Mode Overrides.  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
Overrides  
Discard Overrides  
Save Overrides  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
IA Field Widths  
Supprs  
4233  
Previous Menu  
Off  
2112  
None  
Auto  
Level Rules  
Batching  
AEC Mode  
Film Mode  
Patch Reader 2  
Patch Definition  
Bar Code  
Off  
Lvl 2  
Off  
Duplex  
Confirmation Tone  
N N N  
?????  
1 Roll  
Comic  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
OCR Status  
Off  
On  
Disply  
Off  
COIN User Channel  
Printer Control  
Primary DP-1  
Image Mgmt Code  
Off  
Off  
Xport  
Off  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
Off  
Off  
No Sav  
F
Not Used  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
2. Select the desired override option.  
3-102  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Film Definition  
This mode enables or disables filming.  
This option is set as follows:  
Microimager 70  
F (film)  
Scanners 900, 923, 9500 NoF (no film)  
Scanner/Microimager 990 F (film)  
Microimager 70 Microimager 70/AFM  
Scanner 900  
Scanner 923  
Scanner/Microimager 990  
Scanner 9500  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
MODE 10 Mode Name Ftswitch Pressed  
Undef  
Undef  
Off  
3 Lvl  
Index Format  
IA Display Format  
Ftswitch Released  
Ftswitch Cnf Tone  
Supprs  
4233  
2112  
None  
IA Field Widths  
Level Rules  
Batching  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Off  
Off  
Lvl 2  
Auto  
AEC Mode  
Film Mode  
Reduction Ratio  
# of Cassettes  
Bar Code  
Confirmation Tone  
OCR Status  
Off  
N N N  
Off  
Duplex  
?????  
1 Roll  
COIN User Channel  
On  
Comic  
Off  
Off  
Film Writer  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Disply  
Off  
Off  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Off  
Off  
Xport  
Off  
Check Stacker  
Endorser  
Not Used  
Document Sorter  
Mode Overrides  
Film Definition  
Off  
No Sav  
F
Filming Definition  
Filming Enabled  
Filming Disabled  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
Previous Menu  
A-61097 May 1997  
3-103  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 Installation Questionnaire  
General Information  
CUSTOMER NAME: __________________________________________________________________  
CUSTOMER ADDRESS: _______________________________________________________________  
__________________________________________________________________________________  
CUSTOMER CONTACT: _________________________________PHONE: _______________________  
SALES REPRESENTATIVE: ______________________________PHONE: _______________________  
TRAINER:____________________________________________PHONE: _______________________  
MACHINE ID NUMBER ______________  
MODE  
NUMBER/NAME  
APPLICATION(S)  
1_____________________  
2_____________________  
3_____________________  
4_____________________  
5_____________________  
6_____________________  
7_____________________  
8_____________________  
9_____________________  
10_____________________  
11_____________________  
12_____________________  
13_____________________  
14_____________________  
15_____________________  
16_____________________  
17_____________________  
18_____________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
________________________________________________________  
A-61097 May 1997  
4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Machine Definitions  
0.0 Accessory Status  
9.0  
Messages  
Key  
Definition  
Diagnostic Message - No entry Allowed.  
_____________ Adv. Doc. Controller  
_____________ Bar Code Reader  
_____________ Doc Scanning Array  
_____________ Check Feeder  
_____________ Check Stacker  
_____________ Document Sorter  
_____________ Endorser  
0
1
2
3
4
5
6
7
8
9
_____________ Footswitch  
_____________ Film Writing Module  
_____________ Image Marker  
_____________ Patch Reader 1  
_____________ Patch Reader 2  
_____________ Print Controller  
_____________ Primary Doc Printer 1  
_____________ Secondary Doc Printer 1  
_____________ Doc Printer 12  
_____________ OCR  
10.0 Doc. Printer 12 Print Templates  
(see next page)  
__________ 11.0 Fixed Field Delimiter  
__________ 12.0 System Clock  
13.0 Version Numbers  
___________ AEC  
___________ BARCO  
___________ FDS  
___________ MCP  
___________ OI  
___________ PATCH  
___________ DPC  
__________ 1.0 Machine ID Number  
__________ 2.0 Display Language  
___________ OCR  
___________ SCSI  
___________ U CAS  
___________ L CAS  
___________ LAPTOP  
__________ 3.0 Measurement System  
__________ 4.0 Programmable Function Keys  
Key  
P1  
Definition  
P2  
P3  
P4  
P5  
P6  
P7  
P8  
P9  
P10  
__________ 14.0 User COIN Port Protocol  
User-defined:  
___________ Baud Rate  
___________ Parity Bit  
___________ Character Length  
___________ Handshaking  
15.0 Custom Check Digit  
___________ Attributes  
___________ Constant 1  
___________ Constant 2  
__________ 5.0 Date Format  
___________ Divisor  
____________Delimiter  
__________ 6.0 Time Format  
___________ Left/Right  
___________ LUT Status  
__________ 7.0 Alarm Tone  
___________ Lookup Table  
__________ 16.0 Special Character Set  
__________ 8.0 Confirmation Tones  
no entry  
no entry  
17.0 Save Config to PC  
18.0 Load Config from PC  
4-2  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Print Template #  
PRINT ITEM  
Print Template #  
PRINT ITEM  
Print Template #  
PRINT ITEM  
ITEM LINE  
1
ITEM LINE  
1
ITEM LINE  
1
2
2
2
3
4
5
3
4
5
3
4
5
6
7
8
6
7
8
6
7
8
9
10  
11  
9
10  
11  
9
10  
11  
12  
12  
12  
_
_
_
Print Template #  
PRINT ITEM  
Print Template #  
PRINT ITEM  
Print Template #  
PRINT ITEM  
ITEM LINE  
1
ITEM LINE  
1
ITEM LINE  
1
2
2
2
3
4
5
3
4
5
3
4
5
6
7
8
6
7
8
6
7
8
9
10  
11  
9
10  
11  
9
10  
11  
12  
12  
12  
Print Template #  
PRINT ITEM  
Print Template #  
PRINT ITEM  
Print Template #  
PRINT ITEM  
ITEM LINE  
1
ITEM LINE  
1
ITEM LINE  
1
2
2
2
3
4
5
3
4
5
3
4
5
6
7
8
6
7
8
6
7
8
9
10  
11  
9
10  
11  
9
10  
11  
12  
12  
12  
Print Template #  
PRINT ITEM  
ITEM LINE  
1
2
3
4
5
6
7
8
9
10  
11  
12  
A-61097 May 1997  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mode Definitions  
MODE 1  
Original Setup  
Update (enter date) __________  
31.1 Length Monitor  
31.1 _______ Status  
Filename: _____________.cfg  
May be linked with Mode(s): ________________  
__________ 19.0 Mode Name  
31.2 _______ Max. Doc. Length  
31.3 _______ Min. Doc. Length  
31.4 _______ Error Response  
__________ 20.0 Index Format  
32.0 Skew Monitor  
__________ 21.0 Image Address Display Format  
32.1 _______ Status  
22.0 Image Address Field Widths  
__________ Fixed Field  
32.2 _______ Threshold  
32.3 _______ Error Response  
__________ Field C—Level 3  
__________ Field B—Level 2  
__________ Field A—Level 1  
__________ 33.0 Check Stacker  
34.0 Endorser  
34.1 _______ Status  
23.0 Level Rules  
34.2 _______ Mode  
Level 0 followed by ___________  
Level 1 followed by ___________  
Level 2 followed by ___________  
Level 3 followed by ___________  
34.3 _______ Print Position  
__________ 35.0 Footswitch Pressed  
__________ 36.0 Footswitch Released  
__________ 37.0 Footswitch Confirmation Tone  
__________ 38.0 Patch Reader 1  
__________ 24.0 Batching  
24.1 __________ Batch Level  
24.2 __________ Batch Value  
24.3 __________ Start of Batch  
24.4 __________ End of Batch  
__________ 39.0 Patch Reader 2  
40.0 Patch Definition  
40.1 _______ Xfer Patch Def.  
40.2 _______ Film Xfer Patch  
40.3 _______ Patch Recognition  
__________ 25.0 AEC Mode  
__________ 26.0 Film Mode  
__________ 27.0 Reduction Ratio  
__________ 28.0 Minimum Number of Cassettes  
41.0 Bar Code  
41.1 _______ Status  
41.2 _______ Bar Code Type  
41.3 _______ # of Characters  
41.4 _______ Codes per Doc.  
41.5 _______ Distance Between  
41.6 _______ Scan Direction  
41.7 _______ Image Processing  
41.8 _______ Partial Read  
41.9 _______ Min. Partial Char.  
41.10_______ Patch Reading  
41.11_______ Patch Location  
41.12_______ End Fed Patch  
41.13_______ Level Change  
29.0 Film Writer  
29.1 ________ Char Orientation  
29.2 ________ IA Print Format  
29.3 Write Definitions  
____________ Level 0  
____________ Level 1  
____________ Level 2  
____________ Level 3  
30.0 Image Management Code  
30.1 _______ Status  
30.2 _______ Search Prog. #  
30.3 _______ Magnification  
30.4 _______ Splice Definition  
30.5 _______ Image Mark Sizes  
30.6 _______ Image Polarity  
30.7 _______ Dup. Front Loc.  
30.8 _______ Film Image Orien.  
30.9 _______ Image Offset  
42.0 Confirmation Tones  
42.1 _______ Patch Detected  
42.2 _______ Bar Detected  
42.3 _______ Bar Code/Patch  
__________ 43.0 OCR Status  
4-4  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mode Definitions  
MODE 1  
44.0 COIN User Channel  
44.1 Transmit Data  
________ Level 0  
________ Level 1  
________ Level 2  
________ Level 3  
45.0 Printer Control  
45.1_______ IA Print Format  
45.2_______ Print Position  
45.3_______ Special Char Set  
46.0 Primary Document Printer 1  
46.1_______ Status  
46.2_______ Font/Orientation  
46.3 Print Definitions  
________ Level 0  
________ Level 1  
________ Level 2  
________ Level 3  
47.0 Secondary Document Printer 1  
47.1_______ Status  
47.2_______ Font/Orientation  
47.3 Print Definitions  
________ Level 0  
________ Level 1  
________ Level 2  
________ Level 3  
48.0 Document Printer 12  
48.1_______ Status  
48.2_______ Font/Orientation  
48.3 Print Definitions  
________ Level 0  
________ Level 1  
________ Level 2  
________ Level 3  
49.0 Document Sorter  
49.1_______ Status  
49.2_______ Error Response  
49.3 Sort Criteria  
________ Default Hopper  
________ Item 1/Location  
________ Item 2/Location  
________ Item 3/Location  
__________ 50.0 Mode Overrides  
__________ 51.0 Film Definition  
A-61097 May 1997  
4-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX A : System Map  
Mainframe Configuration  
MACHINE STATE  
Display Machine Accessories  
Machine ID Number  
Display Language  
Measurement System  
Programmable Function Keys  
Date Format  
Time Format  
Alarm Tone  
Doc Printer/Film Writer Msg  
DP-12 Print Template  
Fixed Field Delimiter  
Set System Clock  
Version Numbers  
User COIN Port Protocol  
Custom Check Digit  
OI Hardware Character Set  
Save to PC  
Load from PC  
Mode Configuration  
End Session  
Mode Configuration  
Define Mode 1  
Define Mode 2  
Define Mode 3  
Define Mode 4  
Define Mode 5  
Define Mode 6  
Define Mode 7  
Define Mode 8  
Define Mode 9  
Define Mode 10  
Define Mode 11  
Define Mode 12  
Define Mode 13  
Define Mode 14  
Define Mode 15  
Define Mode 16  
Define Mode 17  
Define Mode 18  
Mode to Mode Copy  
End Session  
Previous Menu  
Mode Number: 10  
Mode Name: MODE10  
Mode Configuration  
MODE 10 Mode Name  
Ftswitch Pressed  
Ftswitch Released  
Ftswitch Cnf Tone  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
Bar Code  
Undef  
Undef  
Off  
Off  
Off  
3 Lvl  
Supprs  
4233  
2112  
None  
Auto  
Index Format  
IA Display Format  
IA Field Widths  
Level Rules  
Batching  
Lvl 2  
On  
AEC Mode  
Duplex  
Film Mode  
Confirmation Tone  
N N N  
?????  
1 Roll  
Comic  
Off  
Off  
Off  
Reduction Ratio  
# of Cassettes  
Film Writer  
Image Mgmt Code  
Length Monitor  
Skew Monitor  
Check Stacker  
Endorser  
OCR Status  
Off  
On  
Disply  
Off  
Off  
Off  
Off  
No Sav  
F
COIN User Channel  
Printer Control  
Primary DP-1  
Secondary DP-1  
Doc. Printer 12  
Document Sorter  
Mode Overrides  
Film Definition  
Xport  
Off  
Not Used  
Save & End Session  
Previous Menu  
Don't Save & End Session  
End Configuration  
A-61097 May 1997  
A-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mode Number: 10  
Mode Name: MODE10  
Mode to Mode Copy  
Copy From Mode:  
Copy Mode 1  
Copy Mode 2  
Copy Mode 3  
Copy Mode 4  
Copy Mode 5  
Copy Mode 6  
Copy Mode 7  
Copy Mode 8  
Copy Mode 9  
Copy Mode 10  
Copy Mode 11  
Copy Mode 12  
Copy Mode 13  
Copy From  
Mode:  
Copy Mode 14  
Copy Mode 15  
Copy Mode 16  
Copy Mode 17  
Copy Mode 18  
Previous Menu  
Select Mode to Copy From  
Mode Number: 10  
Mode Name: MODE10  
Mode to Mode Copy  
Copy From Mode:  
Copy To Mode:  
Copy Mode 1  
Copy Mode 2  
Copy Mode 3  
Copy Mode 1  
Copy Mode 2  
Copy Mode 3  
Copy Mode 4  
Copy Mode 5  
Copy Mode 6  
Copy Mode 7  
Copy Mode 8  
Copy Mode 4  
Copy Mode 5  
Copy Mode 6  
Copy Mode 7  
Copy Mode 8  
Copy Mode 9  
Copy Mode 10  
Copy Mode 11  
Copy Mode 12  
Copy Mode 13  
Copy Mode 14  
Copy Mode 15  
Copy Mode 16  
Copy Mode 17  
Copy Mode 9  
Copy Mode 10  
Copy Mode 11  
Copy Mode 12  
Copy Mode 13  
Copy Mode 14  
Copy Mode 15  
Copy Mode 16  
Copy Mode 17  
Copy From  
Mode:  
01  
Copy Mode 18  
Copy Mode 18  
Previous Menu  
Previous Menu  
Select Copy to Mode 2  
Mode Number: 10  
Mode Name: MODE10  
Mode to Mode Copy  
Are you sure  
you want to  
do this?  
Copy From  
Mode:  
Copy To  
Mode:  
All data in  
the copied  
mode will  
be lost!  
01  
02  
Previous Menu  
Copy to Mode  
Select Copy to Mode  
Downloading Mode Configuration Mainframe  
Send Mode Configuration to Mainframe  
A-2  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX B : Function Codes  
P-Key Definition Input  
Code  
F01  
Function Code Name/Description  
Select Mode  
Allows you to select one of the eighteen (18)  
application modes.  
Required  
Optional  
f01  
,xx 2-digit mode number  
F02  
Restore Mode  
f02  
Allows you to restore the current application mode to  
its default status (as it was defined at installation),  
provided that mode overrides are not saved.  
F03*  
F04  
Filming Only  
Allows you to film documents, with no level counting,  
endorsing, patch reading, etc.  
f03  
f04  
f05  
,0  
,1  
,2  
off/disable  
on/enable  
toggle  
Counting Only  
Allows you to count documents only, with no filming,  
scanning, etc.  
,0  
,1  
,2  
off/disable  
on/enable  
toggle  
F05†  
Accessory Status  
Allows you to display the current status of each  
accessory installed.  
F06†  
F07†  
Terminate Batch  
Allows you to prematurely end a batch  
f06  
f07  
Level 0  
Allows you to assign Level 0 to the next document  
fed into the transport.  
F08†  
F09†  
F10†  
Last Image Address  
Allows you to display the Image Address of the last  
document processed.  
f08  
f09  
f10  
Total Document Count  
Allows you to display the total number of documents  
processed. Also allows you to reset the count to zero.  
Level 0 Count  
Allows you to display the total number of documents  
assigned Level 0. Also allows you to reset the count  
to zero.  
F11†  
Level 1 Count  
f11  
Allows you to display the total number of documents  
assigned Level 1. Also allows you to reset the count  
to zero.  
May be executed while transport is running.  
* Available when filming; for use only with Microimager 70 (with or without AFM), and  
Scanner/Microimager 990.  
** Available when scanning; for use only with the Scanner 900, Scanner 923, Scanner 9500, and  
Scanner/Microimager 990.  
*** Available when using advanced capabilities; for use only with the Microimager 70 (with AFM),  
Scanner 900, Scanner 923, Scanner 9500, and Scanner/Microimager 990.  
A-61097 May 1997  
B-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P-Key Definition Input  
Code  
F12†  
Function Code Name/Description  
Level 2 Count  
Allows you to display the total number of documents  
assigned Level 2. Also allows you to reset the count  
to zero.  
Required  
Optional  
f12  
f13  
f14  
F13†  
F14  
Level 3 Count  
Allows you to display the total number of documents  
assigned Level 3. Also allows you to reset the count  
to zero.  
Reset Level Counts  
Allows you to reset all counters (Level 0, Level 1,  
Level 2, Level 3, and Total) to zero.  
F15  
F16  
F17†  
Alarm Volume  
Allows you to adjust the volume of the alarm.  
f15  
f16  
f17  
Alarm Tone  
Allows you to adjust the pitch of the alarm tone.  
Elapsed Time  
Allows you to display the number of hours the motor,  
transport, and AC have been running, in addition to  
the non-resettable document count.  
F18  
F19  
F20  
Display Contrast  
Allows you to adjust the contrast of the Status  
Display.  
f18  
f19  
f20  
Display Language  
Allows you to choose the language in which the  
Status Display messages will appear.  
Measurement System  
Allows you to choose the measurement system in  
which measurements are displayed.  
F21***  
F22***  
Change Time  
Allows you to change the time.  
f21  
f22  
f23  
f24  
Change Date  
Allows you to change the date.  
F23*** Time and Date Display  
Allows you to view the current time and date.  
F24*  
AEC On/Off  
,0  
,1  
off/disabled  
on/enabled  
Allows you to turn the Automatic Exposure Control on  
or off.  
F25*  
AEC Auto Adjust  
Allows you to adjust the AEC exposure setting when  
the AEC is in Auto Mode (ON).  
f25  
May be executed while transport is running.  
* Available when filming; for use only with Microimager 70 (with or without AFM), and  
Scanner/Microimager 990.  
** Available when scanning; for use only with the Scanner 900, Scanner 923, Scanner 9500, and  
Scanner/Microimager 990.  
*** Available when using advanced capabilities; for use only with the Microimager 70 (with AFM),  
Scanner 900, Scanner 923, Scanner 9500, and Scanner/Microimager 990.  
B-2  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P-Key Definition Input  
Required Optional  
Code  
F26*  
Function Code Name/Description  
AEC Fixed Adjust  
f26  
Allows you to adjust the AEC exposure setting when  
the AEC is in Fixed Mode (OFF).  
F27*  
F28*  
Film Advance  
f27  
Allows you to advance the film in six (6) inch [150  
mm] increments, or by a specific amount input in  
inches or millimetres.  
Film Leader  
f28  
Allows you to create a film leader which is six (6) feet  
[1.8 metres] of blank film.  
F29*  
F30*  
Advance Film to End of Roll  
Allows you to advance the film to the end of the roll.  
f29  
f30  
Display Film Remaining  
Allows you to display the amount of film remaining in  
each film cassette.  
F31*  
F32*  
F33*  
F34  
Lead End Code  
Allows you to create a lead end code for retrieval  
purposes.  
f31  
f32  
f33  
f34  
f35  
f37  
f38  
f39  
f40  
Trail End Code  
Allows you to create a trail end code for retrieval  
purposes.  
Roll Number  
Allows you to display the current roll number and/or  
change to a new roll number.  
Operator ID Number  
Allows you to display the current operator ID number  
and/or change to a new operator ID number.  
F35*  
F37**  
F38**  
F39  
Cassette ID Number  
Allows you to display the current cassette ID number  
and/or change to a new cassette ID number.  
Scanner Calibration  
Allows you to initiate the calibration process required  
before scanning documents.  
Scanner End-of-Job  
Allows you to signal the host computer that the last  
document of the job has been fed into the transport.  
Printer Character Shift  
Allows you to select which set of ink jets will be used  
to print each character.  
F40  
All Document Printers On/Off  
,0  
,1  
off/disable  
on/enable  
Allows you to turn all document printers (primary  
DP1, secondary DP1, and DP12) on or off.  
May be executed while transport is running.  
* Available when filming; for use only with Microimager 70 (with or without AFM), and  
Scanner/Microimager 990.  
** Available when scanning; for use only with the Scanner 900, Scanner 923, Scanner 9500, and  
Scanner/Microimager 990.  
*** Available when using advanced capabilities; for use only with the Microimager 70 (with AFM),  
Scanner 900, Scanner 923, Scanner 9500, and Scanner/Microimager 990.  
A-61097 May 1997  
B-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P-Key Definition Input  
Required Optional  
off/disable  
Code  
F41  
Function Code Name/Description  
Primary DP1 On/Off  
Allows you to turn the primary document printer 1 on  
or off.  
f41  
,0  
,1  
on/enable  
F42***  
Secondary DP1 On/Off  
Allows you to turn the secondary document printer 1  
on or off.  
f42  
,0  
,1  
off/disable  
on/enable  
F43  
Document Printer 12 On/Off  
Allows you to turn the document printer 12 on or off.  
f43  
f44  
,0  
,1  
off/disable  
on/enable  
F44†  
Omit Printing on Next Document Only  
Allows you to omit printing by all document printers  
on the next document only.  
F45  
F46  
F49  
Print Test  
f45  
f46  
f49  
Allows you to test the position and print quality of all  
document printers installed.  
Print Position  
Allows you to specify how far from the leading edge  
of the document all document printers will print.  
Purge Frequency  
Allows you to specify how often, in terms of the  
number of documents fed into the transport, a  
priming ink spurt is initiated.  
F50  
Patch Reader 1 On/Off  
Allows you to turn the primary patch reader on or off.  
f50  
f51  
,0  
,1  
off/disable  
on/enable  
F51***  
Patch Reader 2 On/Off  
Allows you to turn the secondary patch reader on or  
off.  
,0  
,1  
off/disable  
on/enable  
F52***  
F53***  
End Fed Patch Reading On/Off  
Allows you to turn end fed patch reading on or off.  
f52  
f53  
,0  
,1  
off/disable  
on/enable  
Patch Reading Confirmation Tone  
Allows you to turn the patch reading confirmation  
tone on or off.  
,0  
,1  
off/disable  
on/enable  
F54†  
F56  
Omit Patch Reading on Next Document Only  
Allows you to omit patch reading on the next  
document only.  
f54  
f56  
Printer Open Jet Test  
Allows you to determine whether or not there are  
non-functional ink jets in the Document Printer 12 ink  
cartridge.  
F57  
F58  
Endorser On/Off  
Allows you to turn the endorser on or off.  
f57  
f58  
,0  
,1  
off/disable  
on/enable  
Endorser Mode  
Allows you to display the current endorser mode  
and/or change the endorser mode.  
May be executed while transport is running.  
* Available when filming; for use only with Microimager 70 (with or without AFM), and  
Scanner/Microimager 990.  
** Available when scanning; for use only with the Scanner 900, Scanner 923, Scanner 9500, and  
Scanner/Microimager 990.  
*** Available when using advanced capabilities; for use only with the Microimager 70 (with AFM),  
Scanner 900, Scanner 923, Scanner 9500, and Scanner/Microimager 990.  
B-4  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P-Key Definition Input  
Required Optional  
Code  
F59  
Function Code Name/Description  
Endorser Print Position  
f59  
Allows you to specify how far from the leading edge  
of the document the endorsement will appear.  
F60***  
F62***  
Bar Code Reading 1 On/Off  
Allows you to turn bar code reading on or off.  
f60  
f62  
,0  
,1  
off/disable  
on/enable  
Bar Code/Patch Reading Confirmation Tone  
Allows you to turn the bar code/patch reading  
confirmation tone on or off.  
,0  
,1  
off/disable  
on/enable  
F63***  
Bar Code Reading Confirmation Tone  
Allows you to turn the bar code reading confirmation  
tone on or off.  
f63  
f64  
f65  
,0  
,1  
off/disable  
on/enable  
F64*** Omit Bar Code Reading on Next Document Only  
Allows you to omit bar code reading on the next  
document only.  
F65***  
Bar Code Test  
Allows you to perform a test to verify the operation of  
the bar code reader.  
F66***  
F70  
Partial Bar Code Reading On/Off  
Allows you to turn partial bar code reading on or off.  
f66  
f70  
f71  
,0  
,1  
off/disable  
on/enable  
Length Checking On/Off  
Allows you to turn length checking on or off.  
,0  
,1  
off/disable  
on/enable  
F71†  
Omit Length Checking On Next Document Only  
Allows you to omit length checking on the next  
document only.  
F72  
Skew Detection  
Allows you to turn skew detection on or off.  
f72  
f73  
,0  
,1  
off/disable  
on/enable  
F73**  
Latched Scanning Flag  
Allows you to set a flag which alerts the host system  
that the document, and those which follow, are of  
special interest. The flag will remain activated for  
every document until it is turned off.  
F74**  
Momentary Scanning Flag  
Allows you to set a flag which alerts the host system  
that the next document only is of special interest.  
f74  
f75  
F75***  
Footswitch Confirmation Tone  
Allows you to turn the footswitch confirmation tone on  
or off.  
,0  
,1  
off/disable  
on/enable  
May be executed while transport is running.  
* Available when filming; for use only with Microimager 70 (with or without AFM), and  
Scanner/Microimager 990.  
** Available when scanning; for use only with the Scanner 900, Scanner 923, Scanner 9500, and  
Scanner/Microimager 990.  
*** Available when using advanced capabilities; for use only with the Microimager 70 (with AFM),  
Scanner 900, Scanner 923, Scanner 9500, and Scanner/Microimager 990.  
A-61097 May 1997  
B-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P-Key Definition Input  
Required Optional  
off/disable  
Code  
Function Code Name/Description  
OCR On/Off  
Allows you to turn OCR on or off.  
F76  
f76  
f80  
f81  
,0  
,1  
on/enable  
F80  
Document Sorter On/Off  
Allows you to turn the document sorter on or off.  
,0  
,1  
off/disable  
on/enable  
F81†  
F82†  
Sort Next Document to Specified Hopper  
Allows you to specify the hopper (default, upper, or  
lower) in which the next document only will be  
deposited.  
Sort All Documents to Specified Hopper  
Allows you to specify the hopper (default, upper, or  
lower) in which all documents will be deposited. This  
definition will remain in effect for every document  
until it is redefined.  
f82  
F91  
Select Linked Mode  
Allows you to switch from one application mode to  
another, keeping the last Image Address.  
f91  
f92  
f93  
f94  
f95  
f96  
F92  
Fixed Field  
Allows you to enter a new fixed field value, containing  
alphanumeric characters.  
F93***  
F94†  
F95†  
F96†  
Action/Confirmation Tone  
Allows you to adjust the pitch of the  
action/confirmation tone.  
Level 1  
Allows you to assign Level 1 to the next document  
fed into the transport.  
Level 2  
Allows you to assign Level 2 to the next document  
fed into the transport.  
Level 3  
Allows you to assign Level 3 to the next document  
fed into the transport.  
F97  
F98†  
F99  
Next Image Address  
Allows you to input the next Image Address.  
f97  
f98  
f99  
Stop  
Allows you to stop the transport.  
Run  
Allows you to turn on the transport.  
May be executed while transport is running.  
* Available when filming; for use only with Microimager 70 (with or without AFM), and  
Scanner/Microimager 990.  
** Available when scanning; for use only with the Scanner 900, Scanner 923, Scanner 9500, and  
Scanner/Microimager 990.  
*** Available when using advanced capabilities; for use only with the Microimager 70 (with AFM),  
Scanner 900, Scanner 923, Scanner 9500, and Scanner/Microimager 990.  
Available when using advanced capabilities; for use only with the Microimager 70 (with AFM),  
Scanner 900, Scanner 923, and Scanner/Microimager 990.  
B-6  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX C : Recommended Entries  
Item  
Description  
Values  
Item  
Description  
Values  
0.0  
Accessory Status  
PRES (Present)  
NOTPRES (Not Present)  
14.0  
User COIN Port  
Protocol  
NO (Not used)  
YES (Used)  
1.0  
2.0  
Machine ID Number 00 – 99  
Baud rate  
300  
600  
Display Language  
ENG (English)  
1200  
2400  
4800  
9600  
19.2 K  
FREN (French)  
GERM (German)  
ITAL (Italian)  
SPAN (Spanish)  
3.0  
4.0  
5.0  
Measurement  
System  
ENG (English)  
MET (Metric)  
Parity Bit  
NONE (No parity)  
ODD (Odd parity)  
EVEN (Even parity)  
Programmable  
Function Keys  
Enter function(s)  
Character Length  
Handshaking  
7 (7 Bits)  
8 (8 Bits)  
Date Format  
mmddyy  
mmdd  
ddmmmyy  
ddmmm  
mmyy  
None  
CTS/RTS  
yddd  
yyddd  
15.0  
Custom Check  
Digit  
NO (Not used)  
YES (Used)  
yymmdd  
ddmmyy  
mmmddyyyy  
Attributes  
Constant 1  
Constant 2  
Divisor  
11-digit string  
2-digit number  
2-digit number  
2-digit number  
Date Delimiter  
Slash (/)  
Dash (–)  
Period (.)  
Space ( )  
No Del  
Left/Right  
LEFT (Left of decimal)  
RIGHT (Right of decimal)  
6.0  
Time Format  
Alarm Tone  
12 hr AM/PM  
12 hr  
24 hr  
LUT Status  
NO (not used)  
YES (used)  
7.0  
8.0  
High  
Low  
Lookup Table  
11-digit string  
16.0  
Special Character JAP (Japanese)  
Set EURO (European)  
Confirmation Tones ON (Enabled)  
OFF (Disabled)  
17.0  
18.0  
Save Config to PC no entry required  
9.0  
Messages  
Enter messages  
Load Config from  
PC  
no entry required  
10.0  
Doc. Printer 12  
Print Templates  
Enter line number and  
print item(s)  
19.0  
20.0  
Mode Name  
Index Format  
10-digit string  
11.0  
Fixed Field Delimiter Slash (/)  
Dash (–)  
Period (.)  
Space ( )  
1 (Single level)  
2 (Two level)  
2Off (Two level offset)  
3 (Three level)  
Backslash (\)  
3Off (Three level offset)  
12.0  
13.0  
System Clock  
TERM (Terminal time)  
MAN (Manual)  
21.0  
Image Address  
Display Format  
DISP (Display)  
SUPP (Suppress)  
COMP (Compress)  
Version Numbers  
Enter version numbers  
A-61097 May 1997  
C-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
Description  
Values  
Item  
Description  
Image Mark Sizes CUST (Custom)  
KOD (Kodak Standard)  
Values  
22.0  
Image Address  
Field Widths  
0 – 9  
30.5  
30.6  
30.7  
30.8  
Image Polarity  
OPP (Opposite of IM)  
SAME (Same as IM)  
23.0  
Level Rules  
Level 0  
Level 1  
Level 2  
Level 3  
Duplex Front  
Location  
OPP (Opposite of channel)  
SAME (Same as channel)  
24.0  
24.1  
Batching  
Level  
Film Image  
Orientation  
DN (Leading Edge down)  
UP (Leading Edge up)  
None  
Level 1  
Level 2  
Level 3  
30.9  
31.0  
31.1  
Image Offset  
Length Monitor  
Status  
000 – 127  
ON (Enabled)  
OFF (Disabled)  
24.2  
24.3  
Value  
01 – 9999  
Start-of-Batch  
function  
f94 (go to Level 1)  
f95 (go to Level 2)  
f96 (go to Level 3)  
31.2  
Maximum  
02.5000 – 75.000 in.  
Document Length 63.5 – 1905 mm on IL70  
63.5 – 508 on others  
24.4  
End-of-Batch  
function  
f94 (go to Level 1)  
f95 (go to Level 2)  
f96 (go to Level 3)  
f98 (stop)  
31.3  
31.4  
Minimum  
02.500 – 13.000 in.  
Document Length 63.5 – 330.2 mm  
Error Response  
DISP (Display)  
BEEP (Display and Beep)  
STOP (Stop and Display)  
25.0  
26.0  
AEC Mode  
Film Mode  
Auto  
Fixed  
32.0  
32.1  
Skew Monitor  
Status  
SIM (Simplex)  
DUP (Duplex)  
DUO (Duo)  
ON (Enabled)  
OFF (Disabled)  
32.2  
32.3  
Threshold  
5 (5 degrees)  
10 (10 degrees)  
27.0  
Reduction Ratio  
Don’t Care  
24X  
40X  
Error Response  
DISP (Display)  
BEEP (Display and Beep)  
STOP (Stop and Display)  
50X  
28.0  
Minimum Number One  
of Cassettes  
Two  
33.0  
Chek Stacker  
ON (Enabled)  
OFF (Disabled)  
29.0  
29.1  
Film Writer  
34.0  
34.1  
Endorser  
Status  
Character  
Orientation  
Com (Comic)  
CIN (Cine)  
COM180 (Comic 180)  
CIN180 (Cine 180)  
ON (Enabled)  
OFF (Disabled)  
34.2  
34.3  
Mode  
CON (Continuous)  
SIN (Single Stamp)  
29.2  
Image Addres  
Display Format  
DISP (Display)  
SUPP (Suppress)  
COMP (Compress)  
Print Position  
00.000 – 70.000 in.  
0 – 1778 mm  
29.3  
30.0  
Write Definitions  
Enter item(s)  
Not Used  
Image  
Management Code  
35.0  
Footswitch Pressed OFF (Undefined)  
Level 0  
30.1  
30.2  
Status  
ON (Enabled)  
OFF (Disabled)  
Level 1  
Level 2  
Level 3  
INC (Increment)  
SLevel 0 (Sustained)  
SLevel 1 (Sustained)  
SLevel 2 (Sustained)  
SLevel 3 (Sustained)  
F Key  
Search Program  
Number  
00 – 70  
30.3  
30.4  
Magnification  
20 – 80  
Splice Definition  
Ignore  
Level 1  
Level 2  
Level 3  
P Key  
C-2  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
Description  
Values  
Item  
Description  
Values  
36.0  
Footswitch  
Released  
OFF (Undefined)  
Level 0  
41.12 End Fed Patch  
ON (Enabled)  
OFF (Disabled)  
Level 1  
Level 2  
Level 3  
INC (Increment)  
41.13 Level Change  
Level 0  
Level 1  
Level 2  
Level 3  
OFF (Undefined)  
37.0  
38.0  
39.0  
Footswitch  
Confirmation Tone OFF (Disabled)  
ON (Enabled)  
42.0  
42.1  
42.2  
Confirmation Tones  
Patch Detected  
Patch Reader 1  
Patch Reader 2  
Patch Definition  
ON (Enabled)  
OFF (Disabled)  
Bar Code Detected ON (Enabled)  
OFF (Disabled)  
ON (Enabled)  
OFF (Disabled)  
42.3  
43.0  
44.0  
Bar Code/Patch  
Detected  
40.0  
40.1  
Transfer Patch  
Definition  
Level 1  
Level 2  
Level 3  
None  
OCR Status  
ON (Enabled)  
OFF (Disabled)  
COIN User  
Channel  
NO (Not used)  
YES (Used)  
40.2  
40.3  
Film Transfer Patch NO (not filmed)  
YES (filmed)  
44.1  
45.0  
45.1  
Transmit Data  
Print Controller  
Enter data  
Patch Recognition 2 (Type 2)  
3 (Type 3)  
Image Address  
Print Format  
DISP (Display)  
COMP (Compress)  
SUPP (Suppress)  
XFER (Transfer)  
2/3 (Types 2 and 3)  
2X (Types 2 and Transfer)  
3X (Types 3 and Transfer)  
ALL (All types)  
45.2  
45.3  
46.0  
46.1  
46.2  
Print Position  
00.125 – 75.000 in.  
3 – 1778 mm  
Special Character SM (Smaller font)  
Set  
41.0  
41.1  
Bar Code  
Status  
LG (Larger font)  
ON (Enabled)  
OFF (Disabled)  
Primary Document  
Printer 1  
41.2  
Bar Code Type  
3 of 9 (Code 39)  
2 of 5 (Interleaved 2 of 5)  
CODA (Codabar)  
Status  
ON (Enabled)  
OFF (Disabled)  
Font/Orientation  
SCOM (Sm Comic)  
SCIN (Sm Cine)  
41.3  
41.4  
41.5  
41.6  
41.7  
41.8  
41.9  
Number of  
Characters  
03 – 80  
SCOM180 (Sm Comic180)  
SCIN180 (Sm Cine180)  
LCOM (Lg Comic)  
LCIN (Lg Cine)  
LOM180 (Lg Comic 180)  
LCIN180 (Lg Cine 180)  
Codes per  
Document  
ONE ALL  
Distance Between 0.375 – 3.000 in.  
Codes  
09.53 – 76.20 mm  
Scan Direction  
UNI (Uni-directional)  
BI (Bi-directional)  
46.3  
47.0  
Print Definitions  
Enter item(s)  
Secondary  
Document Printer 1  
Image Processing ON (Enabled)  
OFF (Disabled)  
47.1  
47.2  
Status  
ON (Enabled)  
OFF (Disabled)  
Partial Read  
ON (Enabled)  
OFF (Disabled)  
Font/Orientation  
SCOM (Sm Comic)  
SCIN (Sm Cine)  
Minimum Partial  
Read Characters  
03 – 80  
SCOM180 (Sm Comic 180)  
SCIN180 (Sm Cine180)  
LCOM (Lg Comic)  
41.10 Patch Reading  
ON (Enabled)  
OFF (Disabled)  
41.11 Patch Location  
1.92 – 9.60 in.  
LCIN (Lg Cine)  
048.77 – 243.84 mm  
LCOM180 (Lg Comic180)  
LCIN180 (Lg Cine180)  
A-61097 May 1997  
C-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
47.3  
48.0  
Description  
Values  
Print Definitions  
Enter item(s)  
Document  
Printer 12  
48.1  
48.2  
Status  
ON (Enabled)  
OFF (Disabled)  
Font/Orientation  
COM (Comic)  
COM180 (Comic 180)  
48.3  
49.0  
49.1  
Print Definitions  
Document Sorter  
Status  
Enter template  
ON (Enabled)  
OFF (Disabled)  
49.2  
Error Response  
DISP (Display)  
BEEP (Display and Beep)  
Stop (Stop and Display)  
49.3  
50.0  
51.0  
Sort Criteria  
Enter selected criteria  
and bin  
Mode Overrides  
Film Definition  
DIS (Discard)  
SAV (Save)  
Filming Enabled  
Filming Disabled  
C-4  
A-61097 May 1997  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EASTMAN KODAK COMPANY  
Business Imaging Systems  
Rochester, New York 14650  
Kodak, Digital Science, the ds monogram symbol,  
and Imagelink are trademarks of Eastman Kodak  
Company.  
Printed on recycled paper.  
BUSINESS  
IMAGING  
SYSTEMS  
A-61097 5/97  
©Eastman Kodak Company, 1997  
Printed in U.S.A.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Indesit Microwave Oven MWI 14IX User Manual
InSinkErator Indoor Furnishings H778 User Manual
Jura Capresso Coffeemaker IMPRESSA701 User Manual
JVC CRT Television LT 32EX177 User Manual
JVC Digital Camera TK WD310 User Manual
JVC Flat Panel Television GGT0303 001A H User Manual
Jwin CD Player JL K755 User Manual
Kenmore Water Heater 153318031 User Manual
Kenwood Car Stereo System XR S17P User Manual
KitchenAid Outdoor Gas Burner KSBN220PSS User Manual