Ingersoll Rand Marine Radio 23644 400 User Manual

OPERATOR’S MANUAL  
23644Ć400  
RELEASED: 1-30-81  
OPERATION, INSTALLATION & MAINTENANCE  
REVISED:  
(REV. B)  
6-23-00  
23644-400  
ARO STOPR  
PUMP SAVER CONTROL VALVE - 1/2” PIPE SIZE  
READ THIS MANUAL CAREFULLY BEFORE INSTALLING,  
OPERATING OR SERVICING THIS EQUIPMENT  
.
It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.  
GENERAL DESCRIPTION  
This device is to terminate operation of a 4" to 7" reciprocating type air  
motor in the event of a ruptured outlet hose or the pump runs out of meĆ  
dia. For compressed air use only.  
Operating Pressure Range . . . 20 Ć 175 p.s.i. (1.4 Ć 12 bar)  
Temperature Range . . . . . . . . . 0_ to 180_F (Ć18_ to 82_C)  
C
B
A
OPERATION  
The AROĆSTOP control valve senses an increased volume of air to the  
pump, beyond the preadjusted setting, and shuts off the air supply to  
the pump. The runaway" condition may be caused by any of the followĆ  
ing: 1.)depleted pumping material, 2.)a ruptured line on the outlet of  
the pump, 3.)excessive cavitation in the material supply.  
INSTALLATION  
The AROĆSTOP valve should be installed in a filtered and regulated air  
line as close to the inlet of the pump as possible. Equipment other than  
a lubricator should not be installed between the AROĆSTOP valve and  
the inlet of the pump. Upstream plumbing from the AROĆSTOP valve  
should be 1/2" minimum. A swivel or 1/2" connector & coupler shouldbe  
installed before the AROĆSTOP valve to facilitate easy adjustment.  
Use one AROĆSTOP valve for each pump. See typical installation phoĆ  
to.  
ADJUSTMENT  
THE AROĆSTOP VALVE MUST BE PROPERLY ADJUSTED AND  
TESTED. THE INSTALLATION SHOULD BE TESTED REGULARLY  
AND ADJUSTED WHEN A CHANGE IN OPERATING CONDITIONS  
OCCURS.  
1. Turn A" sleeve clockwise to the maximum inward position. See arĆ  
row on sleeve of AROĆSTOP valve.  
and run, repeat step (5). If pump operates, continue on th Test SecĆ  
tion.  
TEST:  
7. To test installation, with the pump operating, remove the pump (or  
siphon tube)from the material supply. If the pump shuts off, the unit  
is set properly.  
2. Supply AROĆSTOP valve with desired inlet operating pressure.  
3. Depress C" reset button on the AROĆSTOP valve to start the  
pump. Open the pump outlet to the desired flow condition.  
4. Turn A" sleeve counterclockwise slowly until the pump stops.  
5. Turn A" sleeve clockwise one turn and tighten B" locking nut  
against body.  
8. If the pump continues to turn, resubmerge the pump (or siphon  
tube)in the material supply. Loosen the B" locking nut and turn the  
A" sleeve counterclockwise approx. one half turn, tighten B" lockĆ  
ing nut, and repeat step (7).  
RESTART:  
9. To restart: Remedy the cause of the shutdown. If the air supply is  
shutĆoff, turn the air back on.  
10. Depress the C" reset button and hold it in approx. 3 seconds.  
6. To restart pump, depress the C" reset button and hold it in for  
approx. 3 seconds or until pump primes. If the pump does not reset  
AROĆSTOPR is a registered trademark of The Aro Corporation.  
INGERSOLL-RAND COMPANY  
P.O. BOX 151 D ONE ARO CENTER D BRYAN, OHIO 43506Ć0151  
&
(419) 636-4242  
D
FAX (419) 633-1674  
E2000 D PRINTED IN U.S.A.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Indesit Washer Dryer WIL143UK User Manual
Intel Computer Hardware 915GM User Manual
Intel Network Card 10 Gigabit AF DA Dual Port Server Adapte User Manual
Invacare Mobility Aid 2GRTM User Manual
Jensen Car Stereo System CD510K User Manual
Jensen Portable Speaker SMPS 225 User Manual
Jet Tools Saw HVBS 56M User Manual
JL Audio Car Speaker SB GM C6CONV 8W3v3 User Manual
Keurig Coffeemaker 7092 User Manual
KitchenAid Mixer 9706978A User Manual